THERMOWELL NOTES:
1A. INTERNAL HYDROSTATIC PRESSURE TEST @ 3000 PSI.
1B. MANUFACTURE'S STANDARD TOLERANCES APPLY, UNLESS NOTED OTHERWISE.
1C. THERMOWELL TO BE STAMPED WITH 'TW' TAG#, MATERIAL, SERIAL#, MANUFACTURER NAME,
AND 'U' DIMENSION.
1D. ALL DIMENSIONS TO BE IN INCHES.
1E. THERMOWELL SHANK TO BE 4-16 Ra SURFACE FINISH.
1F. THERMOWELL SHANK SHALL BE SINGLE-PIECE CONSTRUCTION, 1-3/8" OD HEX BAR STOCK
3
FOR 1" NPT PROCESS CONNECTION. 4" 'T' 1" 'U'
DOCUMENTATION (UPON REQUEST):
2A. WAKE FREQUENCY ANALYSIS (VELOCITY/VIBRATION CALCULATIONS) PER ASME PTC 19.3-2010.
(A) ALL CALCULATION RESULTS AND DIMENSIONAL DRAWINGS SHALL BE APPROVED BY CITGO 'Q'
PRIOR TO START OF THERMOWELL FABRICATION.
2B. MTRs (MILL TEST REPORT) FOR BAR STOCK.
2C. INTERNAL HYDROSTATIC PRESSURE TEST REPORT.
2D. POSITIVE MATERIAL IDENTIFICATION TEST REPORT. 'V'
.281" BORE
THERMOWELL (OPTIONS): 'D'=1-3/8"
1" PROCESS CONNECTION
CODE DESIGN
T TAPERED
S STRAIGHT
CODE THERMOWELL MATERIAL
1 316SS 'A'= 'U' + 'T' + 134" - 't' 't'=41"
2 304SS
3 MONEL 400
4 INCONEL 600
5 HASTELLOY C-276
OTHER (PLEASE SPECIFY)
FTAM16-1053
CODE 'U' (INSERTION LENGTH)
PLEASE SPECIFY
THERMOWELL THERMOWELL 'T' 'U' 'Q' 'V'
DESIGN MATERIAL LAGGING INSERTION ROOT TIP
EXTENSION LENGTH DIAMETER DIAMETER
CODE 'T' (LAGGING EXTENSION)
PLEASE SPECIFY
CODE 'Q' (ROOT DIAMETER)
PLEASE SPECIFY
CODE 'V' (TIP DIAMETER)
PLEASE SPECIFY TOLERANCES
REVISIONS (UNLESS STATED OTHERWISE)
DIMENSIONS
REV DESCRIPTION DATE REV. BY APPROVED 'D', 'Q', 'V': ± 0.01"
(IF APPLICABLE TO DRAWING)
DIMENSIONS
'C', 'A', 'U', 'H', 't': ± 1/16"
5700 HARTSDALE DRIVE, HOUSTON, TX 77036 (713) 780-8600
(IF APPLICABLE TO DRAWING)
ALL OTHER DIMENSIONS: DATE: SCALE: DRAWN BY: APPROVED BY: REV
.X: ± .1" 08/10/16 NONE KER MEV 0
.XX: ± .01"
.XXX: ± .005"
FRACTIONS: ±1/16" SHEET: 1 OF 1
PROPRIETARY DRAWING CITGO STANDARD SCREW-IN THERMOWELL ASSEMBLY
ANGLES: ±5°
This document is the property of Daily Thermetrics Corporation and Daily Instruments DWG NO.
Corporation, and is delivered on the express condition that it and the technical data and RADII: ±1/16"
information embodied herein are not to be used, disclosed, or reproduced in whole or in CHAMFERS: ±1/16"
part, for any purpose without the express written approval of Daily Thermetrics TIR: ±10% WALL THICKNESS
FTAM16-1053
Corporation or Daily Instruments Corporation.
CONCENTRICITY: ± .010"