DS-3T1506HP-EI-UPS
4 Port Gigabit Smart Managed Industrial Solar PoE Switch
DS-3T1506HP-EI-UPS is a multi-functional POE switch specifically designed by Hikvision for solar power scenarios, offering
flexible energy-saving options, enabling remote monitoring of the health status of solar batteries, and providing a variety of
voltage input and output choices to adapt to different scenarios.
4 x Gigabit PoE Ports, 2 × Gigabit SFP
Support 802.3bt Hi-PoE, Max. 90 W for one port
Support 24 V passive PoE output for wireless bridge, etc.
Support 12 V to 24 V solar power input, DC 54 V input
Wider Temperature (-40 °C to 75 °C) Design
Support battery health monitoring via Hik-Partner Pro and Hik-Connect
Support power consumption schedule
6 kV Surge Protection
Specification
General
Net Weight 0.7 kg (1.54 lb)
Gross Weight 1.16 kg (2.56 lb)
Dimensions (W × H × D) 158.00 mm × 44.00 mm × 130.00 mm (6.22'' × 1.73'' × 5.12'')
Operating Temperature -40 °C to 75 °C (-40 °F to 167 °F)
Storage Temperature -40 °C to 85 °C (-40 °F to 185 °F)
Operating Humidity 5% to 95% (no condensation)
Relative Humidity 5% to 95% (no condensation)
Power Supply 12 V DC, 10 A or 24 V DC, 5 A; 54 V 2.22 A
Installation Mode Desk-Mounted,Rail
Max. Power Consumption 300 W
Power Consumption in Idle 2W
Surge Protection 6 kV
Shell Metal material, IP30
Network Parameters
Ports 4 × Gigabit PoE port,2 × Gigabit fiber optical port,1 x RS485 port
MAC Address Table 2K
Whole-Device Performance: 14 Gbps
Switching Capacity
Port Performance: 12 Gbps
Whole-Device Performance: 10.42 Mpps
Packet Forwarding Rate
Port Performance: 8.93 Mpps
Internal Cache 1 Mbits
PoE Power Supply
Port 1: IEEE 802.3af, IEEE 802.3at, IEEE 802.3bt
Ports 2 to 4: IEEE 802.3af, IEEE 802.3at
PoE Standard
Ports 3 to 4: support passive PoE, 24 V or 54 V output depending on DIP switch
settings
Port 1: 8-pin power: 1/2(-), 3/6(+), 4/5(+), 7/8(-)
PoE Power Pin Port 2: End-span: 1/2(-), 3/6(+)
Ports 3 to 4: 8-pin power: 1/2(-), 3/6(+), 54 V output ; 4/5(+), 7/8(-), 24 V output
Hi-PoE: Port 1
PoE Port
PoE: Ports 2 to 4
Port 1: 90 W
Max. Port Power
Ports 2 to 4: 30 W
DC 54 V input: 120 W
PoE Power Budget
DC 12 V~24 V input: 60 W
Software Function
Ports 1 to 4: up to 300 m.
Long Range
Long range performance may vary depend on camera model or cable condition.
Ports 1 to 6: port isolation mode to improve network security
Port Isolation Ports in an isolation group cannot communicate with each other, but they can
communicate with ports outside the isolation group.
PoE Watchdog Ports 1 to 4: auto detect and restart the cameras that do not respond.
Link aggregation is used to aggregate multiple physical ports to form a logical port for
load balancing, bandwidth expansion, and port protection.
Link Aggregation
Support static link aggregation.
Support 2 aggregation group(s).
Loop prevention is used to prevent the switching network from forming loops, which
will seriously affect network communication. Disabled by default.
Loop Prevention Support 802.1D STP.
Support 802.1w RSTP.
Support G.8032 ERPS.
VLAN is used for network scale planning and network health improvement.
Support 802.1Q.
VLAN Configurable VLAN ID from 1-4094.
Support Trunk, Access port mode.
Support Max. 4094 VLAN.
Support one-click activation and remote management via Hik-Partner Pro. Functions
supported:
1. Display the port rate.
2. Display the port bandwidth utilization rate.
3. Display the PoE power usage.
HPP
4. Display topology information.
5. Display the alarm status.
6. Restart ports and devices.
7. Enable port long-rage mode.
8. Remotely upgrade the device.
Support device management via web.
Support DHCP Client. Enabled by default for dynamic assignment of management IP
addresses.
Support Super IP, which is a fixed IP address (10.180.190.200) for direct access.
Support management via Hik-Central Pro.
System Maintenance
Support remote management via Hik-Partner Pro.
Support cable detection. Abnormal open circuits and short circuits as well as network
cable length can be detected.
Support 802.1ab LLDP for peer device discovery.
Support port mirroring for fault locating.
DHCP Snooping can prevent unauthorized connections to DHCP servers from
DHCP Snooping disrupting the network and affecting normal network communication, and only allow
DHCP packets from trusted ports to pass through. Disabled by default.
Approval
CE-EMC (EN 55032: 2015+A11: 2020, EN IEC 61000-3-2: 2019, EN 61000-3-3: 2013+A1:
EMC 2019, EN 50130-4: 2011+A1: 2014, EN 55035: 2017+A11: 2020),IC (ICES-003: Issue
7:2020),RCM (AS/NZS CISPR 32: 2015)
CB (AMD1:2009, AMD2:2013, IEC 62368-1: 2014 (Second Edition)), CE-LVD (EN 62368-
Safety
1: 2014+A11: 2017)
Chemistry CE-RoHS (2011/65/EU),WEEE (2012/19/EU),Reach (Regulation (EC) No.1907/2006)
Available Model
DS-3T1506HP-EI-UPS
Key Component
Order Sap Order Model Type Parameter
Industrial AC/DC Power Supply, Output 48V-55V, 0-1.6A, 75watts, Input 90-264VAC,
303703680 NDR-75-48
Power Supply 127-370VDC, DIN rail, -20~70°C
Industrial AC/DC Power Supply, Output 48V-55V, 0-5A,240watts, Input 90-264VAC,
303703681 NDR-240-48
Power Supply 127-370VDC, DIN rail, -20~70°C
Industrial AC/DC Power Supply, Output 48V-55V, 0-10A, 480watts, Input 90-
303703682 NDR-480-48
Power Supply 264VAC, 127-370VDC, DIN rail, -20~70°C
Typical Application
Physical Interface
Front Panel
Side Panel
No. Indicator/ Port Description
Press and hold the reset button for more than 5 seconds to restore all the configurations of
① Reset Button
the switch to default settings.
Solid on: The port is connected.
② LINK/ACT Indicator Flashing: The port is transmitting data.
Unlit: The port is disconnected or connection is abnormal.
Solid on: The switch supplies power to a powered device (PD) normally.
③ PoE Indicator
Unlit: The switch is disconnected from a PD or power supply is abnormal.
3A:
Solid on: 54 V standard PoE is enabled for port 3.
Unlit: 54 V standard PoE is disabled for port 3.
3B:
Solid on: 24 V non-standard PoE is enabled for port 3.
Unlit: 24 V non-standard PoE is disabled for port 3.
④ Function Indicator
4A:
Solid on: 54 V standard PoE is enabled for port 4.
Unlit: 54 V standard PoE is disabled for port 4.
4B:
Solid on: 24 V non-standard PoE is enabled for port 4.
Unlit: 24 V non-standard PoE is disabled for port 4.
Gigabit SFP Fiber Solid on: The gigabit SFP fiber optical port is connected.
⑤
Optical Port Indicator Flashing: The gigabit SFP fiber optical port is transmitting data.
Unlit: No gigabit SFP fiber optical port connected or connection is abnormal.
Used for connection to a PD via a network cable.
⑥ Gigabit PoE RJ45 Port Note: Port 1 of the switch is a Hi-PoE RJ45 port, which can be connected to a high-power
device.
Gigabit SFP Fiber Used for connection to another device via an optical fiber when plugged into with an
⑦
Optical Port optical module.
Solid on: The output power of the switch is about to reach or has reached the upper
limit. The power supply may be abnormal if more devices are connected.
Unlit: The switch supplies power to a PD normally and its output power does not reach
⑧ PoE-MAX Indicator
the upper limit.
Note: The PoE-MAX indicator will be unlit in 5 seconds after the output power of the
switch returns to normal.
Solid on: The switch is powered on normally.
⑨ PWR Indicator
Unlit: No power supply is connected or power supply is abnormal.
Select DC 54 V for normal power input or DC 12-24 V for solar power input as required.
DC 54 V: Use a self-prepared power cord and power adapter to connect the switch to
a power socket.
⑩ Power Supply
DC 12-24 V: Use two self-prepared power cords to connect the DC positive electrode
to the battery positive electrode and the DC negative electrode to the battery
negative electrode respectively.
⑪ Grounding Terminal Used for connection to the grounding cable to protect the switch from lightning.
1 (24 V/54 V for port 3):
When the DIP switch 1 is set to Port3 24V, port 3 can be compatible with 24 V forced
PoE powered devices, such as wireless bridges.
When the DIP switch 1 is set to 54V, port 3 only supplies power to IEEE 802.3af/at PoE
powered devices, such as IPCs.
2 (24 V/54 V for port 4):
When the DIP switch 2 is set to Port4 24V, port 4 can be compatible with 24 V forced
⑫ DIP Switch
PoE powered devices, such as wireless bridges.
When the DIP switch 2 is set to 54V, port 4 only supplies power to IEEE 802.3af/at PoE
powered devices, such as IPCs.
3 (All indicators off/on):
When the DIP switch 3 is set to ALL LED OFF, all indicators on the switch except the
PWR indicator are unlit to save power.
When the DIP switch 3 is set to ON, all indicators on the switch are solid on.
Reserved for the switch to acquire battery information, such as battery voltage, current,
⑬ RS485 interface
state of charge (SOC), etc.
Dimension
Accessory
Optional
NDR-75-48 NDR-240-48 NDR-480-48 DS-2XS6K01-C120S180
Industrial Power Supply Unit Industrial Power Supply Unit Industrial Power Supply Unit Solar Power Modules