48x Server Installation Guide
Table of Contents
1 Installation Overview .....................................................................................................................................1
2 Unpacking .....................................................................................................................................................2
3 Chassis Views ...............................................................................................................................................3
4 Mechanical ....................................................................................................................................................5
4.1 Tabletop Placement ..............................................................................................................................5
4.2 Rack Mount ...........................................................................................................................................5
4.2.1 Consider When Mounting..................................................................................................................6
4.3 Wall Mount ............................................................................................................................................7
5 Electrical........................................................................................................................................................9
5.1 Power Connection.................................................................................................................................9
5.2 Chassis Ground ....................................................................................................................................9
5.3 Power-Up Sequence .............................................................................................................................9
5.4 Safe Mode Sequence .........................................................................................................................10
6 Server Configuration ...................................................................................................................................11
7 Ethernet Connectivity ..................................................................................................................................12
8 Analog Telephony .......................................................................................................................................13
9 T1 ................................................................................................................................................................14
10 Accessories (Optional) ................................................................................................................................15
10.1 Line IN/OUT ........................................................................................................................................15
10.2 Terminal Block ....................................................................................................................................15
10.3 Serial Port ...........................................................................................................................................15
11 Physical and Environmental Specifications.................................................................................................16
12 Regulatory Notices ......................................................................................................................................17
12.1 FCC Part 68 ........................................................................................................................................17
12.2 Industry Canada..................................................................................................................................17
12.3 Radio and Television Interference ......................................................................................................18
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx, a wholly owned subsidiary of PAETEC Holding. All other names may be trademarks or
registered trademarks of their respective owners.
Version:1. Revised: July 15, 2010
Page i
48x Server Installation Guide
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx, a wholly owned subsidiary of PAETEC Holding. All other names may be trademarks or
registered trademarks of their respective owners.
Version:1. Revised: July 15, 2010
Page ii
48x Server Installation Guide
1 Installation Overview
Installation of the Allworx® 48x involves the following steps:
1. Unpacking
2. Mechanical Installation
3. Electrical Installation
4. Server Configuration
5. Network Installation
6. Telephony Installation
7. T1 Installation
8. Accessories Installation
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 1
48x Server Installation Guide
2 Unpacking
Open the box and carefully unpack it. Save all shipping and packaging materials. Verify all items against the
parts list shown in Table 1. If any items are missing, contact your dealer or Allworx Customer Support at 866-
255-9679.
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 2
48x Server Installation Guide
3 Chassis Views
Figure 1: Front Chassis View
1 2 3 4 5 6 7 8 9 10 11
1 Power switch
Press & Release – Normal shutdown within a few seconds
Press & Hold – Forced shutdown
2 Power LED – Indicates system start up activity
3 Activity LEDs – Green indicates mounted drive; blinking light indicates activity
4 Two (2) USB Host Ports
5 Door relay port
6 RJ-45 10BaseT/100BaseTX Auto-Sensing Auto-MDI/MDIX Local Area, Wide
Area, and Demilitarized Zone (DMZ)* Network Ethernet ports.
7 T1 Ports (A/B)
8 RJ-11 Power Fail analog phone connector
9 RJ-11 loop-start FXO for central office connection (Ports 1-3)
10 RJ-11 FXS ports for inside extensions (Ports 4-8)
11 3.5 mm stereo audio mini jack for music-on-hold (input) and overhead paging
(output)
*
Future Feature
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 3
48x Server Installation Guide
12 13 14 15 16
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 4
48x Server Installation Guide
4 Mechanical
4.1 Tabletop Placement
To install the Allworx 48x on a tabletop or shelf:
3. Turn over the chassis and place one foot at each corner on the bottom of the chassis.
1. Verify that there is sufficient clearance around the server’s front and rear panels to allow power, network,
and telephony connections.
2. Place the brackets so that the smaller face of the bracket extends away from the front of the unit to
accommodate installation into the rack (See Figure 3).
3. Install the mounting brackets on each side of the server chassis using the four 6-32 flat head screws.
4. Proceed to the Power Connection (Section 5.1) instructions and perform the steps appropriate for your
installation before placing the system into the rack.
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 5
48x Server Installation Guide
4.2.1 Consider When Mounting
• Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than room ambient. Therefore, consideration
should be given to installing the equipment in an environment compatible with the maximum ambient
temperature (40°C).
• Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
• Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition
is not achieved due to uneven mechanical loading.
• Circuit Overloading - Consideration should be given to the connection of the equipment to the supply
circuit and the effect that overloading of the circuits might have on overcurrent protection and supply
wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this
concern.
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 6
48x Server Installation Guide
Note: For wall mount installations, discard included power cord and use only a UL listed power cord of type
SJ or SO or better.
Caution: The Allworx server must be securely mounted to the wall to avoid equipment damage or
personal injury.
Note: The unit must be mounted with the front facing left or right, not up or down (See Figure 5).
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 7
48x Server Installation Guide
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 8
48x Server Installation Guide
5 Electrical
5.1 Power Connection
Warning: Failure to follow these steps may result in equipment damage, personal injury, and a voided
product warranty.
Insert the female end of the power cord into the receptacle on the rear of the unit. Connect the other end to
the power source. The product is rated 115/230 VAC, 1/0.7A, and 50/60Hz. The Allworx server will
automatically begin to power up once the power has been stable for a few seconds. This is part of the design
to automatically boot up after a power failure.
To help prevent electrical shock, the separate protective earthing terminal, located next to the power jack on
the rear panel, must be permanently connected to earth using 18 AWG wire or larger. (See Figure 2, item 14)
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 9
48x Server Installation Guide
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 10
48x Server Installation Guide
6 Server Configuration
The Allworx 48x provides an administrative interface to configure and administer the server. The administrative
interface is accessed using a web browser. Assuming the network settings are set to their factory defaults, the
steps to connect to this interface are:
2. Set up the PC’s network interface to obtain an IP address automatically (using DHCP).
3. Verify that the PC has an IP address on the 192.168.2.x network. You may need to release and renew the
PC’s IP address to get an address from the server.
5. When the “Welcome to Allworx” page appears, login using the default password: admin.
When the Home page appears, click on the Install Checklist link (on the left hand side) to bring up a new
window containing steps necessary to set up a new system. Each brief step description is followed by a link to
get to the appropriate administrative web page to execute the step. These steps are ordered to aid in a
successful configuration. Most of the web pages used to execute each step contain detailed feature
descriptions and help instructions that are required to carry out the step. Use the Allworx System
Administrator’s Guide** as a supplement for the information on the web pages when necessary.
If the server has been previously configured for another installation, you should restore it to its factory default
configuration. This can be done by:
1. Rebooting the server to Safe Mode by holding down the power button when the server is off, or selecting
Maintenance / Restart, and Enter Safe Mode after restart.
2. Format the disk and perform a Software Update (See Allworx System Administrator’s Guide** for
instructions).
**
Allworx System Administrator’s Guide for the can be found at www.allworx.com
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 11
48x Server Installation Guide
7 Ethernet Connectivity
The Local Area Network (LAN), Wide Area Network (WAN), and Demilitarized Zone (DMZ)* data network ports
are 10BaseT/100BaseTX auto-sensing and auto-MDI/MDIX ports.
SIP phones connect to the server just as any other data network device. The phones and the server need to be
properly configured. See the Server Configuration (Section 6) for more information.
The Allworx 48x is a sophisticated network appliance that must be properly configured before being connected
to the LAN, WAN, and DMZ*.
Note: Do not plug any network or ISP service into the server without first properly configuring the server.
Failure to heed this warning may result in a disruption of network connectivity with other equipment on
the network.
After the unit is properly configured, the LAN, WAN, and DMZ* network infrastructure cables can be plugged
in. Standard RJ-45 category 5 network cables must be used.
The LED’s on the LAN, WAN, and DMZ* ports are defined in Table 4.
*
Future Feature
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 12
48x Server Installation Guide
8 Analog Telephony
Caution: To reduce the risk of fire, use only 26 AWG (or larger) UL listed or CSA certified
telecommunications line cord.
The server’s analog phone connections can be used to connect Central Office (CO) lines or telephone
handsets. Table 5 below describes the ports:
The Power Fail Phone port may be used to connect an analog phone device that is operational in the event
that the server loses power or fails. During power failure, it automatically connects to the first outside phone
line port (port 1).
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 13
48x Server Installation Guide
9 T1
T1-A and T1-B interface pin-outs for typical service connections as shown in Table 6, may require either a
straight through cable or a cross-over cable.
Pin Description
1 Receive (ring)
2 Receive (tip)
3 Not Used
4 Transmit (ring)
5 Transmit (tip)
6 Not Used
7 Not Used
8 Not Used
Table 6: T1 Connector Wiring
The Allworx 48x is designed for T1 “short haul” use and has a fully integrated Channel Service Unit / Data
Service Unit (CSU/DSU). An external CSU/DSU is not required and should not be used. The Allworx 48x
should be connected directly to the on-site smart jack or local T1 device using the proper cabling. Do not
connect the Allworx 48x directly to the "long haul" wire pairs exiting the building.
Note: Do not plug any network or ISP service into the server without first properly configuring the server.
Failure to heed this warning may result in a disruption of network connectivity with other equipment on
the network.
After the unit is properly configured, the T1 network infrastructure cables can be plugged in. Standard RJ-45
T1 cables must be used.
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 14
48x Server Installation Guide
10 Accessories (Optional)
10.1 Line IN/OUT
Connect the output from your music and paging system to the server using a Y-Adapter Audio Cable (See
Figure 6). Insert the 3.5mm stereo plug (See Figure 7) into the audio connector labeled Line IN/OUT on the
front panel (See Figure 1 item 11). A stereo splitter (not included) is required to use both Music-On-Hold and
Overhead Paging collectively.
Note: The white audio channel is used for music input and the red audio channel is used for paging output
(See Figure 6).
Figure 6: Y-Adapter Audio Cable Figure 7: Audio Plug Diagram
Line In
GND
The connector is shared with the serial port (See Figure 1, item 5). The pin-out is shown in Table 8 below.
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 15
48x Server Installation Guide
6 Relay NC --
1 Relay NO --
Table 8: Door Relay Pin-Out
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 16
48x Server Installation Guide
12 Regulatory Notices
12.1 FCC Part 68
This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA. On the bottom of
this equipment is a label that contains, among other information, a product identifier in the format US:
AAAEQ##TXXXX. If requested, provide this number to the telephone company.
A plug and jack to connect this equipment to the premises wiring and telephone network must comply with the
applicable FCC Part 68 rules and requirements adopted by the ACTA.
The REN is used to determine the number of devices that may be connected to a telephone line. Excessive
RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most but not
all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be
connected to a line, as determined by the total RENs, contact the local telephone company. For products
approved after July 23, 2001, the REN for this product is part of the product identifier that has the format
US:AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of
0.3). For earlier products, the REN is separately shown on the label.
If this equipment causes harm to the telephone network, the telephone company will notify you in advance that
temporary discontinuance of service may be required. But if advance notice isn't practical, the telephone
company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint
with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations or procedures that could
affect the operation of the equipment. If this happens, the telephone company will provide advance notice in
order for you to make necessary modifications to maintain uninterrupted service.
If trouble is experienced with this equipment, for repair or warranty information, please contact our company. If
the equipment is causing harm to the telephone network, the telephone company may request that you
disconnect the equipment until the problem is resolved.
Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any
repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the
telecommunications company cause to request the user to disconnect the equipment.
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 17
48x Server Installation Guide
Users should ensure for their own protection that the electrical ground connections of the power utility,
telephone lines and internal metallic water pipe system, if present, are connected together. This precaution
may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves, but should contact the
appropriate electric inspection authority, or electrician, as appropriate.
NOTICE: This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications.
This is confirmed by the registration number. The abbreviation, IC, before the registration number signifies that
registration was performed based on a Declaration of Conformity indicating that Industry Canada technical
specifications were met. It does not imply that Industry Canada approved the equipment.
AVIS: Le présent matériel est conforme aux spécifications techniques d’Industrie Canada applicables au
matériel terminal. Cette conformité est confirmée par le numéro d'enregistrement. Le sigle IC, placé devant le
numéro d'enregistrement, signifie que l’enregistrement s’est effectué conformément à une déclaration de
conformité et indique que les spécifications techniques d'Industrie Canada ont été respectées. Il n’implique pas
qu’Industrie Canada a approuvé le matériel.
NOTICE: The Ringer Equivalence Number (REN) for this terminal equipment is 0.1. The REN assigned to
each terminal device provides an indication of the maximum number of terminals allowed to be connected to a
telephone interface. The termination on an interface may consist of any combination of devices subject only to
the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5.
AVIS : L'indice d'équivalence de la sonnerie (IES) du présent matériel est de 0.1. L'IES assigné à chaque
dispositif terminal indique le nombre maximal de terminaux qui peuvent être raccordés à une interface
téléphonique. La terminaison d'une interface peut consister en une combinaison quelconque de dispositifs, à la
seule condition que la somme d'indices d'équivalence de la sonnerie de tous les dispositifs n'excède pas 5.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 18
48x Server Installation Guide
You may also find helpful the following booklet, prepared by the FCC: "How to Identify and Resolve Radio-TV
Interference Problems.” This booklet is available from the U.S. Government Printing Office, Washington D.C.
20402.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can
void your authority to operate this equipment under Federal Communications Commissions rules.
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set
out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n'emet pas de bruits radioélectriques depassant les limites applicables aux
appareils numérique de la class B préscrites dans le Règlement sur le brouillage radioélectrique édicte par le
Ministere des Communications du Canada.
300 Main Street • East Rochester, NY 14445 • Toll Free 1-866-ALLWORX • 585-421-3850 • www.allworx.com
© 2010 Allworx Corp. All rights reserved. Allworx is a registered trademark of Allworx Corp. All other names may be trademarks or registered
trademarks of their respective owners.
Version: 1. Revised: July 15, 2010
Page 19