0% found this document useful (0 votes)
130 views52 pages

GK250

The document provides a comprehensive overview of the SUPER UNIT and HYBRID HYDRAULIC UNIT models, detailing their specifications, features, and applications in high-pressure and high-flow rate scenarios. It includes model lists categorized by pressure and flow rate, along with electrical component requirements and installation diagrams. The document emphasizes the energy-saving and high-accuracy capabilities of Daikin's servo-based pump control systems.

Uploaded by

betaviets
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
130 views52 pages

GK250

The document provides a comprehensive overview of the SUPER UNIT and HYBRID HYDRAULIC UNIT models, detailing their specifications, features, and applications in high-pressure and high-flow rate scenarios. It includes model lists categorized by pressure and flow rate, along with electrical component requirements and installation diagrams. The document emphasizes the energy-saving and high-accuracy capabilities of Daikin's servo-based pump control systems.

Uploaded by

betaviets
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 52

INDEX

High Pressure High Flow Rate List of Super Unit


Models
P.1 to 2

Analog Command Input High Accuracy

SUPER UNIT
Nomenclature P.3

Features P.4 to 5

HYBRID HYDRAULIC UNIT Functions P.6

Circuit Configuration P.7 to 8


Examples
Exceeds standard of high efficiency
motor regulation Specifications P.9 to 12

About Continuous
and Short-time P.13
Rating Range

Command Voltage - Control


Pressure / Control Flow Rate P.14
Characteristic Examples

Pressure – Flow Rate


Characteristics P.15 to 17
(Single pump)

Pressure – Flow
Rate Characteristics P.18 to 20
(Double pump)

External Dimension
Diagrams P.21 to 24
(Single pump)

External Dimension
Diagrams P.25 to 28
(Double pump)

External Dimension
Diagrams P.29 to 31
(Controller)

List of Electrical P.32


Components

Electric Wiring P.33 to 39


Diagram

8-PQ control P.41 to 42

Example Control P.43

Timing Chart of a P.44 to 46


Press

Maintenance/

Unique Offer from DAIKIN!!


Management Tool P.47 to 48
(Hybrid-Win)

External/Installation
Dimension Diagrams for P.49 to 50

Unparalleled energy-saving and high-accuracy


Electrical Components

servo-based pump PQ control system


- An extensive lineup of pump control systems covering a wide
range of applications including presses and industrial machinery -
Oil Hydraulic Division
Oil Hydraulic Equipment
Specifications vary depending on the machine type.
List of SUPER UNIT Models The Daikin product lineup provides various functions
and capacities according to the machine type.

Maximum
discharge
rate SUPER UNIT (Analog Command Input, High-accuracy Type) Model List by Pressure/Flow Rate

300 S-SUT00S30018 S-SUT00D30025


L/min
380 V 380 V

250 S-SUT00S25018
L/min
380 V

200 SUT00S20018 SUT00D20021 S-SUT00D20021 S-SUT00D20025 SUT00D20028


L/min
400 V 200 V 400 V 400 V 400 V

150 SUT00S15018 SUT00D15021 SUT00D15028


L/min
200/400 V 200/400 V 200/400 V

130 SUT00S13018 SUT00S13021 SUT00D13021 S-SUT00D13025 SUT00D13028


L/min
200/400 V 200 V 200/400 V 400 V 200/400 V

80 SUT00S8018 SUT00D8021 S-SUT00D8025 SUT00D8028


L/min
200/400 V 200 V 400 V 200/400 V

50 SUT00S5021 S-SUT00S5025
L/min 200/400 V 200 V

30 SUT00S3018 SUT00D3021
L/min 200 V 200 V

Maximum (Note 5)
operating
pressure 18 MPa 21 MPa 25 MPa 28 MPa
Note 1 All models allow selection of the input type as the analog command input type or 8-PQ digital command input type using a parameter. (Factory default is the analog command input type.)
Note 2 All models are tankless units with a split type controller (electrical components).
Note 3 Flow rate/pressure combinations other than those given in the model list above are also available. Please consult us when considering adoption.
Note 4 When a discharge rate higher than 300 L/min is required, it can be achieved by combining multiple SUPER UNITs. Please consult us for detailed information.
Note 5 We plan to develop 28 MPa specifications sequentially from October 2016 to March 2017. Please consult us for detailed information.

Maximum
discharge
SUPER UNIT (High-functionality Type) Model List by Pressure/Flow Rate
rate

110 SUT00S11007 200 V SUT00D11021 200 V


L/min
P-SUT20D11KW

80 SUT00S8007 200 V SUT00D8021 200 V


L/min SUT10S8007 SUT10D8021
SUT16D8021

60 SUT00S6007 200 V SUT00D6021 200 V


L/min SUT06S6007 SUT06D6021
SUT10D6021

40 SUT00S3007 200 V SUT00D4016 200 V


L/min SUT03S3007 SUT06D4016

30 SUT00S4007 200 V SUT00S3010 200 V SUT00S3016 200 V


L/min SUT03S4007 SUT03S3010 SUT06S3016

15 SUT00S1507 200 V SUT00S1510 200 V SUT00S1516 200 V


L/min SUT03S1507 SUT03S1510 SUT03S1516

Maximum
operating
pressure
7 MPa 10 MPa 16 MPa 21 MPa
Note 1 All models are 16-PQ control type units. The communications type and analog command input type (single pump type only) can be selected as optional models.
Note 2 A motor pump type (tankless) and unit type (with tank) are available. Please refer to the separately provided SUPER UNIT catalog (GK244) for details.

01
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

Power Maximum
Nominal motor Maximum Maximum flow rate [L/min]
supply Flow rate operating PQ 8-PQ Figure

List of Super Unit Models


Series capacity [kW] flow rate Model
voltage selection pressure chart No. function Page No.
(Equivalent) [L/min] 30 50 80 100 130 150 180 200 250 300
[V] [MPa]
7 17.6 30 SUT00S3018-30-A 1  21
11 20.6 50 SUT00S5021-30-A 2  21
AC3φ
11 — 17.6 80 SUT00S8018-30-A 3  21
200V
15 24.5 50 SUT00S5025-10-L-N0432 4  22
15 17.6 150 SUT00S15018-10-A 5  23

Single 11 20.6 50 SUT00S5021-20YA-N0265 6  21


pump type 11 17.6 80 SUT00S8018-21YA 7  21
15 17.6 130 SUT00S13018-10YA-N0218 8  23
15 AC3φ 20.6 130 SUT00S13021-11YA-N0286 9 None 23

15 400V 17.6 150 SUT00S15018-10YA 10  23
22 17.6 200 SUT00S20018-20YL-N0340 11  23
37 17.6 250 S-SUT00S25018-10YA 12 16-PQ 24
45 17.6 300 S-SUT00S30018-10YA 13 16-PQ 24
Combination 17.6 30
7 SUT00D3021-30-B-N0436 14  25
Independent 20.6 18.3
Combination 17.6 80
11 SUT00D8021-30-B-N0323 15  26
Independent 20.6 38.4
AC3φ Combination 20.6 130
15 SUT00D13021-10-B-N0321 16 None 26
200V Independent 20.6 47.9
Combination 17.6 150
15 SUT00D15021-10-B-N0365 17 None 26
Independent 20.6 70.9
Combination 11.5 200
15 SUT00D20021-10-L 18 None 27
Independent 25.0 56
Combination 17.6 80
11 SUT00D8021-21YB-N0324 19  26
Independent 20.6 38.4
Double Combination 20.6 130
pump type 15 SUT00D13021-10YB-N0322 20  26
Independent 20.6 47.9
Combination 17.5 150
15 SUT00D15021-10YB-N0358 21  26
Independent 20.6 70.9
Combination 11.5 200
15 S-SUT00D20021-12YL 22  27
AC3φ Independent 25.0 56
400V Combination 15.0 80
11 S-SUT00D8025-11YL 23  27
Independent 25.0 40
Combination 15.0 130
15 S-SUT00D13025-11YL 24  27
Independent 25.0 37.3
Combination 16.5 200
22 S-SUT00D20025-20YL 25  28
Independent 25.0 56
Combination 17.5 300
47 S-SUT00D30025-10YA 26 16-PQ 28
Independent 25.0 160
Note 1 All models are tankless motor pump type units. The input type can be selected either as the analog command input type or 8-PQ (16-PQ) digital command input type using a parameter.
Note 2 The numbers in the PQ chart No. column in the above table correspond to the figure numbers in the “PQ characteristic chart” later in this catalog.
Note 3 Please refer to P32 “List of Electrical Components” for the electrical components that need to be arranged separately for each of the models indicated above.

Power Maximum Maximum


Nominal motor Maximum flow rate [L/min] Tank
supply Flow rate operating Motor pump type Unit type
Series capacity [kW] flow rate capacity
voltage selection pressure (tankless) (with tank)
(Equivalent) [L/min] 10 20 30 40 50 60 70 80 90 100 110 [L]
[V] [MPa]
2.2 7.0 15.2 SUT00S1507-30 SUT03S1507-30 30
2.8 7.0 28.5 SUT00S3007-30 SUT03S3007-30 30
3.7 7.0 39.7 SUT00S4007-30 SUT03S4007-30 30
5.0 7.0 61.1 SUT00S6007-30 SUT06S6007-30 60
Single 7.0 AC 3φ 7.0 83.0 SUT00S8007-30 SUT10S8007-30 100
pump type 200 V —
11.0 7.0 110 SUT00S11007-30 — —
2.8 10.0 15.2 SUT00S1510-30 SUT03S1510-30 30
3.7 10.0 25.6 SUT00S3010-30 SUT03S3010-30 30
3.7 16.0 15.2 SUT00S1516-30 SUT03S1516-30 30
5.0 16.0 25.6 SUT00S3016-30 SUT06S3016-30 60
Combination 7.0 41.0
3.7 SUT00D4016-30 SUT06D4016-30 60
Independent 15.7 8.7
Combination 7.0 61.1 SUT06D6021-30 60
5.0 SUT00D6021-30
Double AC 3φ Independent 20.6 7.7 SUT10D6021-30 100
pump type 200 V Combination
7.0 83.0 SUT10D8021-30 100
7.0 SUT00D8021-30
Independent 20.6 14.2 SUT16D8021-30 160
Combination 7.0 110.0
11.0 SUT00D11021-30 P-SUT20D11KW-30 200
Independent 20.6 28.4
Note 1 Please refer to the separately provided SUPER UNIT catalog (GK244) for specifications and external appearances.

02
Nomenclature

SUT 00 S 300 18 10 Y A R 


a b c d e f g h i j

a Model code g Power supply voltage*1

● SUT : SUT series ● − : AC 200 V specifications


● S-SUT : S-SUT series ● Y : AC 400 V specifications

b Tank capacity h Functional option code


● 00 : Motor pump type (tankless) ● A : Analog command input type, with discharge block
with safety valve
● B : Analog command input type, with discharge block
c Pump type without safety valve
● L : Analog command input type, with discharge block
● S : Single pump type without safety valve
● D : Double pump type

i Motor terminal box (viewed from pump side)


d Pump discharge rate ● No designation : Terminal box at the right side (standard)
● 30 : 30 L/min ● R : Terminal box at the left side
● 50 : 50 L/min
● 80 : 80 L/min
● 130 : 130 L/min j Non-standard code
● 150 : 150 L/min
● “N” + non-standard number designated for each specification
● 200 : 200 L/min
Non-standard No.: Specifications such as the 10V input
● 250 : 250 L/min
specification or with suction flange
● 300 : 300 L/min
● No designation: Standard (5V input specification, separate
arrangement of controller’s electrical
e Maximum operating pressure components, etc.)

● 18 : 17.6 MPa
● 21 : 20.6 MPa
● 25 : 25.0 MPa

f Design No.
● 10 : Design No.
Incremented at model changes

*1
200/400 V cited as power supply voltage specifications are nominal voltages.
Refer to the specification tables and separately provided model drawings for details on the operating range.

03
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT
Main Features and Functions
High The analog command input/high-accuracy type SUPER UNITs have operating ranges
Voltage/High extended to include high pressure and high flow rate ranges, enabling PQ control with
Flow Rate even greater accuracy than conventional SUPER UNITs (high-functionality type).

Achieving stable servo control in response to analog input voltages over a range from
High low pressure (1%)/flow rate (1%) to the maximum pressure/flow rate.
Accuracy The double pump type units enable low-pressure/high-flow-rate control in the combination flow mode, and
high-pressure holding (continuous) control over a prolonged period in the individual flow mode.

Superior energy-saving hydraulic systems suited to applications with industrial machinery

Type Code / Specifications


Energy Saving such as presses and general industrial machines while offering high performance, easy
operation and reasonable prices.
As an alternative to directly specifying command values for pressure and flow rate with
Two Types of analog voltage inputs, the operation conditions can be selected easily by using 3-bit
Operation ON/OFF digital signals that can call eight different preset pressure/flow rate patterns.
Commands (8-PQ type: Selectable using a parameter)

Features

Energy Saving
Energy savings at least 60% greater than conventional fixed displacement pump systems
(The energy-saving effect varies depending on the operation conditions.)
Average power
● Significant reduction of running costs with a small investment. 40 consumption:
Power consumption (kW)

Contributes to improvement of production efficiency at a


35
30
21.5 kW
reasonable price. 25
20
15
600-t press machine 10
5
Pump model Fixed-displacement pump  SUT00D8025
0
Average power consumption 21.5 kW  13.9 kW 0 20 40 60
Time (sec)
80 100 120

Effect of reduced power consumption: $6,350 (¥635,000) / year


* Electricity rate: $0.16 (¥16) / kWh, Annual operating hours: 5,220 hours / year
70 Average power
Power consumption (kW)

60 consumption:
50
13.9 kW
Oil cooler downsized by suppressing oil temperature rise 40
30
● Fewer oil changes by restricting hydraulic oil deterioration. 20

Further, downsizing the hydraulic oil tank and oil cooler reduces 10

the amount of hydraulic oil and cooling water used. 0


0 20 40 60 80 100 120
Time (sec)

High Accuracy with Simple Operation


High-accuracy servo control according to analog pressure (P) / flow rate (Q) voltage commands
● Easy to use, just like conventional Example with double pump type (SUT00D15021-10-B)
proportional valves.
● The servo-controlled pump adjusts the PI-PO static characteristics QI-QO static characteristics

pressure and flow rate in accordance with the 24 200

load. 20
150
● Highly accurate control with respect to
Flow rate [L/min]
Pressure [MPa]

16

pressure/flow rate command values, with a 12 100

linearity of 1% F.S. maximum and hysteresis 8


Linearity ≤ 1%F.S Linearity ≤ 1%F.S
50
of 1% F.S. maximum. 4
Hysteresis ≤ 1%F.S Hysteresis ≤ 1%F.S

0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Pressure command PI [V] Flow rate command QI [V]
Low-pressure control: Low flow rate control:
Minimum control pressure = 1% F.S. or higher Minimum control flow rate = 1% F.S. or higher

04
Main Features and Functions

Features

Sustained High-pressure Holding Control


Sustained high-pressure control with energy savings by selecting the pump flow rate
 Double pump type units enable selection of combination or independent flow rate using a dedicated solenoid valve to achieve
sustained high-pressure control, switching between a low pressure with high flow rate and a high pressure with low flow rate,
as is often required for presses and other equipment.
 The solenoid valve can be switched autonomously by the SUPER UNIT or from the machine, according to the parameter
setting.

Faster Shipping Adjustment


Simple adjustment to start a trial run on the machine, meaning a shorter adjustment time
 The SUPER UNIT can be easily adjusted without requiring special skills for setting/adjusting complicated parameters of servo
systems. The unit runs stably even with the default settings so the machine can reach the trial run stage in a short time.

Economical replacement of conventional hydraulic systems with servo-controlled pump


systems
 Conventional hydraulic systems with proportional valves can be economically replaced with next-generation energy-saving
high-accuracy servo-controlled pump systems, where the pump discharge rates and pressures are servo-controlled, by using
analog command input type SUPER UNITs.
 Even hydraulic systems that do not incorporate proportional valves can be replaced with energy-saving hydraulic systems that
can achieve stable control with a simple pressure/flow rate adjustment.
 The command input method can be selected, by parameter setting, as the analog command input type (0 to 5 V or 0 to 10 V)
or the 8-PQ pattern input type using 3-bit digital ON/OFF input signals.
(Factory default is the analog command input type.)

Improving the Working Environment


Reduced noise during operation
 Noise while holding a high pressure is reduced by lowering the rotational speed of the pump to the minimum level required to
hold the pressure.
 Shockless control of pressures and flow rates can be achieved by ramping the command voltages during
acceleration/deceleration of the pressure and flow rate. This gives smooth machine operation with less impact noise, helping
to improve your working environment.

Ambient air temperature rise reduced by restricting oil temperature rise


 Temperature rise of the hydraulic oil raises the ambient temperature, which leads to a poor working environment.
The energy-saving SUPER UNIT restricts hydraulic oil temperature rise to the minimum, helping to maintain a comfortable
working environment.

Exceeds Standard of High Efficiency Motor regulation


Incorporating a motor dedicated to servo-based rotational speed control
 Exceeds standard of high efficiency motor regulations eliminates complicated formalities both in Japan and when exporting the
machine.
 Since no induction motor is used, the maximum discharge rate of the pump does not fluctuate depending on the power supply
frequency, making it unnecessary to adjust the machines’ maximum speed for each shipping destination.

05
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

Functions

Maintenance/Management Function Software

Editing/Saving Parameter Settings

Equipped with RS232C communications port as default, DAIKIN’s maintenance/


waveform measurement software (Hybrid-Win) provided

Features/Functions
 The software tool Hybrid-Win, which can manage default parameter settings, read the alarm history, and save parameter data,
allows easy maintenance and management of the SUPER UNIT simply by preparing a personal computer (Windows 7/8) and
a communications cable (RS232C/USB conversion cable).

Displaying and Recording Waveform Graphs during SUPER UNIT Operation


 During service work or adjustment for test runs, the pressure and flow rate commands at the SUPER UNIT and the result of
pressure and flow rate control can be monitored and displayed in the form of graphs using Hybrid-Win software. The
waveforms can also be saved in the PC. This speeds up adjustment of SUPER UNIT parameters and troubleshooting.

Collecting Data for Predictive Maintenance (*1)


 Periodically collecting, monitoring and analyzing those data on the results of SUPER UNIT control using the RS232C
communications port opens up the possibility of new approaches to maintenance and management such as predictive
maintenance.

Note: A personal computer with Windows 7/8 operating system and an RS232C/USB conversion cable are necessary.
Communications cables (3-core soldered cables PM-CM02-15 for 1.5 m and PM-CM02-30 for 3 m) are available as options (to be ordered separately).
Note: Hybrid-Win is a software tool to provide functions for editing or saving parameters and measuring waveforms of a SUPER UNIT, and runs on a personal computer
connected to the SUPER UNIT using a communications cable.
Hybrid–win and its instruction manual are available free of charge from the website (http://www.daikinpmc.com/) after registering as a member.
(*1) Please consult us for detailed information on predictive maintenance.

06
Circuit Configuration Examples (Double pump specifications)

Example hydraulic press circuit

Circuit at the machine side

CYL-2
Main cylinder
CYL-1 (upper die)

SOL5

SOL1A SOL1B SOL2A SOL2B SOL3A SOL3B SOL4A SOL4B


A B A B A B A B

P T P T P T P T

Machine’s
setting unit

Safety valve (*2)


SUPER UNIT
system
SUPER UNIT
SUPER UNIT flow rate A P controller
selection block Pi pressure command
(Separately installed type) (*1) B T Pressure sensor
Qi flow rate command

Low-pressure
pump
High-pressure
pump
M
Rotary encoder

Motor pump

(*1) There are two types of flow rate selection circuit, the type built into the pump discharge block and the separately installed type.
(*2) A safety valve needs to be incorporated in hydraulic circuits at the pump discharge side for safety.

07
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

System block diagram for SUT00D flow rate selection specifications

Maintenance software
(Hybrid-Win)

Circuit Configuration Examples


PC software tool To machine side circuit
(safety valve incorporated at the machine side)
Flow rate selection block
(separately installed type, 25 MPa)

Power supply Discharge port P1


RS232C
3-phase AC 380 to 400 V
P2 (Plugged)
50/60 Hz
Machine
side
Pressure
Pressure command voltage sensor
(Pi) DC 0 to +10 V
φ0.7
PS
Flow rate command voltage
T3
(Qi) DC 0 to +10 V
(Plugged)

Pressure monitor voltage


(Po) DC 0 to +10 V SUPER UNIT
Controller
section
Flow rate monitor voltage IPM motor
(Qo) DC -10 to +10 V
PL PH
Combination/independent
Thermistor
pump selection signal (DI5) SUPER UNIT
Motor pump section

Combination/independent Encoder
pump selection solenoid valve, Suction port T1 T2
DC 24 V control voltage

Cooling fan
Fan power supply Machine side
1-phase AC 215 to 245 V 50/60 Hz

Solenoid valve turned ON/OFF at the machine side:


ON for combination flow (DI5 at the controller turned ON at the same time)
(Forced switching by external signal)

08
06
Specifications by Product (Single pump 200 V/400 V specifications)
200 V specifications 400 V specifications
SUT00S SUT00S S-SUT00S

13018-10YA-N0218

13021-11YA-N0286

20018-20YL-N0340
5021-20YA-N0265
5025-10-L-N0432

15018-10YA

25018-10YA

30018-10YA
15018-10-A

8018-21YA
3018-30-A

5021-30-A

8018-30-A
Model

Item
Maximum operating pressure [MPa] 17.6 20.6 17.6 24.5 17.6 20.6 17.6 17.6 20.6 17.6 17.6
Maximum flow rate [L/min] 30 50 80 50 150 50 80 130 150 200 250 300
Operating pressure 0.18 0.21 0.18 0.25 0.18 0.21 0.21
[MPa] 0.18 to 17.6 0.18 to 17.6 0.18 to 17.6
adjustment range to 17.6 to 20.6 to 17.6 to 24.5 to 17.6 to 20.6 to 20.6
Operating flow rate
adjustment range [L/min] 0.3 to 30 0.5 to 50 0.8 to 80 0.5 to 50 1.5 to 150 0.5 to 50 0.8 to 80 1.3 to 130 1.5 to 150 2.0 to 200 7.5 to 250 9.0 to 300

Pump Pump type Single geared pump Single geared pump Single geared pump
model
Pump capacity [cm3] 9.13 20.7 31.2 27.4 52.7 20.7 31.2 44 52.7 73 − −
3-phase AC 380 V
Controller input power (*1) 3-phase AC 200 to 220 V (50 Hz/60 Hz) 3-phase AC 380 to 440 V(50 Hz/60 Hz) (50 Hz/60 Hz)
Permissible power supply
voltage fluctuation range –15% to +10% –20% to +10% −15% to +15%

Power Required power


supply capacity [kVA] 11.3 23.2 33.8 20.1 34.8 52 83.0
supply

1-phase AC 200 V ±10% 1-phase AC 215 to 245 V 1-phase AC 230 V ±15%


Motor cooling fan power (50 Hz/60 Hz) (50 Hz/60 Hz) (50 Hz/60 Hz)

Controller control power (*2) − − DC 24 V ±10% 0.2 A

[min ] −1
2,340 1,800 1,800 −
Rated value
[N⋅m] 28 58.4 58.4 − 117 −
Controller rated input current [A] (*3) 25.3 35.6 20 23.3 19 − 40 88.0 114.0
Motor rated input current [A] (*3) 29.2 38.3 27.5 27.7 21 − 45 73.2 88.9
Leak current [mA] (*3) − − 3 3.2 2.1 − 2.8 8.9
Motor pump [kg] 40 69 70 92 103 69 70 103 104 103 118 246 342
Controller [kg] 11 11 − 14 52 63
Mass Regenerative [kg]
resistance unit − 12

Regenerative
[kg] − 3
brake unit
Analog command input voltage DC [V] (*4) 0 to +5 0 to +10 0 to +10

Non-standard Suction flange/block Incorporated None Incorporated None Incorporated None Incorporated None Incorporated Incorporated
specifications Safety valve (*5) Incorporated None Incorporated Incorporated None Incorporated

(*1) Even if the unit is used within the permissible power voltage fluctuation range, the PQ output characteristics may deteriorate if the power voltage fluctuates to the negative side.
Also note that power voltage fluctuation to the positive side may cause alarms, due to overloading of regenerative operation, depending on the operation conditions. You are
therefore recommended to use the unit in an environment with limited power voltage fluctuation as far as possible.
(*2) With the S-SUT00S25018 and S-SUT00S30018 specifications, the DC 24 V control power (0.2 A minimum) needs to be input at the same time as the controller’s AC power
supply voltage.
(*3) Representative values when using a noise filter recommended by DAIKIN. Protection against noise, in accordance with DAIKIN’s recommendations, may be required
depending on the operating environment.
(*4) With 5 V analog command input voltage specifications, the voltage can be adjusted from 0 to 5 V using parameter VMAX. With 10 V specifications, the voltage can be adjusted
from 0 to 10 V, so it can also be operated with 5 V inputs.
(*5) With models without a safety valve in the discharge block, incorporate a safety valve in the hydraulic circuit at the machine side. Use the unit with the safety valve set at the
maximum operating pressure + 2 MPa.

09
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

Specifications by Product (Double pump 200 V/400 V specifications)


200 V specifications 400 V specifications
SUT00D SUT00D S-SUT00D

13021-10YB-N0322

15021-10YB-N0358
13021-10-B-N0321

15021-10-B-N0365

8021-21YB-N0324
3021-30-B-N0436

8021-30-B-N0323

30025-10YA
20021-12YL

13025-11YL

20025-20YL
20021-10-L

8025-11YL
Model

Item

Maximum Combination [MPa] 17.6 20.6 17.6 11.0 17.6 20.6 17.6 11.0 15.0 17.0 17.5
operating pressure Independent [MPa] 20.6 25.0 20.6 25.0
Combination [L/min] 30 80 130 150 200 80 130 150 200 80 130 200 300
Maximum flow rate
Independent [L/min] 18.3 38.4 47.9 70.9 56.0 38.4 47.9 70.9 56.0 40.0 37.0 56.0 160.0
Operating pressure
adjustment range [MPa] 0.21 to 20.6 0.25 to 25 0.21 to 20.6 0.25 to 25

Specifications
Operating flow rate
adjustment range [L/min] 0.3 to 30 0.8 to 80 1.3 to 130 1.5 to 150 2.0 to 200 0.8 to 80 1.3 to 130 1.5 to 150 2.0 to 200 0.8 to 80 1.3 to 130 2.0 to 200 9.0 to 300

Pump type Double geared pump Double geared pump


Pump
model Pump Combination [cm3] 9.1 31.2 44.0 52.7 74.1 31.2 44.0 52.7 74.1 33.4 41.1 74.1 −
capacity
Independent [cm3] 5.6 15.0 16.2 24.9 20.8 15.0 16.2 24.9 20.8 16.7 16.6 20.8 −
3-phase
Controller input power (*1) 3-phase AC 200 to 220 V (50 Hz/60 Hz) 3-phase AC 380 to 440 V (50 Hz/60 Hz) AC 380 V
(50 Hz/60 Hz)
Permissible power supply
voltage fluctuation range –15% to +10% –20% to +10% −15% to +15%

Required power
Power supply capacity [kVA] 11.3 23.2 33.8 20.1 34.8 34.8 20.1 34.8 52 84.0
supply
1-phase
Motor cooling fan power 1-phase AC 200 V ±10% (50 Hz/60 Hz) 1-phase AC 215 to 245 V (50 Hz/60 Hz) AC 230 V ±15%
(50 Hz/60 Hz)
DC 24 V ±10%
Controller control power (*2) − − 0.2 A
Flow rate selection DC 24 V − −
(*3) DC 24 V ±10% (*5) DC 24 V ±10% (*5) − (*6) (*6)
solenoid valve power (*4) (*6)

[min-1] 2,340 1,800 1,800 −


Rated value
[N⋅m] 28 58.4 58.4 79.6 58.4 79.6 79.6 58.4 79.6 117 −
Controller rated input current [A] (*7) 25.3 35.6 20 23.3 23.3 19 26 26 19 26 40 118
Motor rated input current [A] (*7) 29.2 38.3 27.5 27.7 27.4 21 29 29 21 29 45 88.9
Leak current [mA] (*7) − − 3.2 3.2 3.9 2.1 3.9 3.9 2.1 3.9 2.8 8.9
Motor pump [kg] 40 76 109 109 99 76 109 99 65 98 119 342
Controller [kg] 10 10 14 63

Mass Regenerative [kg] − 12


resistance unit
Regenerative [kg] − 3
brake unit

Analog command input voltage DC [V] (*8) 0 to +10 0 to +10

Non-standard Suction flange/block Incorporated Incorporated


specifications Safety valve (*9) None Incorporated

(*1) Even if the unit is used within the permissible power voltage fluctuation range, the PQ output characteristics may deteriorate if the power voltage fluctuates to the negative side.
Also note that power voltage fluctuation to the positive side may cause alarms, due to overloading of regenerative operation, depending on the operation conditions. You are
therefore recommended to use the unit in an environment with limited power voltage fluctuation as far as possible.
(*2) With the S-SUT00S25018 and S-SUT00S30018 specifications, the DC 24 V control power (0.2 A minimum) needs to be input at the same time as the controller’s AC power
supply voltage.
(*3) Please refer to “List of Electrical Components” for the electrical components required.
(*4) Solenoid valve model: KSOB-G02-9AP-40-N-H7 (minute signal current type solenoid valve, power supply voltage: DC 24 V ± 10%)
(*5) Solenoid valve model: KSO-G03-20BP-20-EN (power supply voltage: DC 24 V ± 10%)
(*6) Not equipped with a solenoid valve for flow rate selection (Arrange a separately installed type flow rate selection block or provide a flow rate selection mechanism in the
hydraulic circuit at the machine side.)
(*7) Representative values when using a noise filter recommended by DAIKIN. Protection against noise, in accordance with DAIKIN’s recommendations, may be required
depending on the operating environment.
(*8) With 5 V analog command input voltage specifications, the voltage can be adjusted from 0 to 5 V using parameter VMAX. With 10 V specifications, the voltage can be adjusted
from 0 to 10 V, so it can also be operated with 5 V inputs.
(*9) With models without a safety valve in the discharge block, incorporate a safety valve in the hydraulic circuit at the machine side. Use the unit with the safety valve set at the
maximum operating pressure + 2 MPa.

10
Common Specifications
Specifications by Product (Single pump
(30 L/min to 200200
L/min,V/400 V specifications)
single/double pump, 200 V/400 V specifications)

Item Specifications
Command resolution: 0.1 [%]
Analog command input (*1) 5 V specifications: 0 to +5 V / 0 to PMAX
Pressure command Pi
10 V specifications: 0 to +10 V / 0 to PMAX
(2ch)
Flow rate command Qi 5 V specifications: 0 to +5 V / 0 to PMAX
10 V specifications: 0 to +10 V / 0 to PMAX
Pressure monitor Po 5 V specifications: 0 to +5 V / 0 to PMAX
Analog output (*1) 10 V specifications: 0 to +10 V / 0 to PMAX
(2 ch) 5 V specifications: -5 to +5 V / -QMAX to +QMAX
Flow rate monitor Qo
10 V specifications: -10 to +10 V / -QMAX to +QMAX
Photo-coupler insulation, DC +24 V (27 V maximum), 5 mA/channel
Shared positive/negative common
DI1 Start/stop signal (control stop signal)
Digital input signal (*2)
(8 ch) DI3, DI4, DI6 PQ number selection signal for 8-PQ type (3-bit)
DI5 Pump capacity selection input (for flow rate selection specifications)
DI2, 7, 8 (Unassigned)
Photo coupler insulation, open collector, DC +24 V, 30 mA maximum
Negative common
DO1 Ready to operate signal
Digital output signal (*3)
(7 ch) DO3 Pump capacity selection output (for autonomous flow rate selection specifications)
DO4 Overload warning output (OFF: normal, ON: Warning)
DO5 to 7 (Unassigned)
Contact output (alarm) (1 ch) Dry contact: DC 30 V, 1 channel, 500 mA maximum
Motor pump No paint, only fan cover is in black
Paint color
Controller Ivory white (Munsell code 5Y7.5/1)
Oil type Mineral-oil base hydraulic oil, wear resistance hydraulic oil
Oil temperature 0 to 60 [°C] (Recommended operating temperature range: 15 to 50 [°C])
Oil used (*4) Viscosity grade ISO VG32 to 68
Viscosity range 15 to 400 mm2/s
Contamination Within NAS class 9
Indoors (not exposed to direct sunlight)
Atmosphere Not to be subject to corrosive gases, inflammable gases, oil mist or dust
Altitude 1,000 m maximum
Ambient humidity 85% RH maximum (no dew condensation)
Operating Ambient Motor pump 0 to 40°C (no freezing)
environment temperature Controller 0 to 55°C (no freezing)

Installation Motor pump To be secured on the base for the hydraulic unit on the machine. To be installed horizontally
orientation Controller To be installed inside an electrical cabinet (IP54). To be installed in the vertical orientation (with the main power supply terminals at the bottom)
Controller IP00
Protection grade
Motor (*5) IP44

Storage Motor pump −20 to +70°C (no freezing)


Storage temperature Controller −20 to +60°C (no freezing)
environment
Storage Motor pump
85% RH maximum (no dew condensation)
humidity Controller
Startup time 5 seconds maximum (at ambient temperature of 15°C)
Power supply grounding type TN
(a) Install a no fuse breaker on the main power supply to protect electrical circuits from overcurrent, in the event of short circuits for
example.
Others (b) Be sure to connect the ground terminals of the controller and motor pump.
(c) Frequently turning the controller’s power supply ON/OFF will substantially shorten the controller’s service life. It is advisable to start
and stop the motor by turning the digital input (DI1) ON/OFF.

(*1) There are two different voltage specifications: 5 V specifications and 10 V specifications. The PMAX and QMAX settings can be selected
using parameters. The input and output voltage settings can be selected using parameter VMAX.
(*2) When incorporating a semiconductor relay in the circuit, select a product with a leak current specification of 1 mA maximum.
(*3) When incorporating a relay in the circuit as a load, take necessary measures against surge or select a surge-resistant product.
(*4) Consult DAIKIN about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.
(*5) The shaft through hole, encoder connector, motor cooling fan and terminal block are excluded.

11
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

Common Specifications (250 L/min to 300 L/min, single/double pump, 400V specifications)
Item Specifications
Command resolution: 0.1 [%]
Analog command input (*1)
Pressure command Pi 0 to +10 V/0 to PMAX
(2 ch)
Flow rate command Qi 0 to +10 V/0 to QMAX
(An output harness is used only for the models with the non-standard code “-001” or “-003”.)
Analog output (*1) Pressure monitor Po 0 to +9.99 V/0 to PMAX
(2 ch)
Flow rate monitor Qo 0 to +9.99 V/0 to QMAX
Photo-coupler insulation, DC +24 V (27 V maximum), 5 mA/channel
Shared positive/negative common
DI1 Start/stop signal (control stop signal)
DI2 Regenerative brake unit alarm signal
Digital input signal (*2) DI3 Regenerative resistance unit alarm signal
(5 ch)
DI4, DI5, DI6, DI7 PQ number selection signal for 16-PQ type (4-bit, 18 MPa specifications)
DI7 Pump capacity selection input (flow rate selection, analog command input specifications)
DI4 to 7 (Not used, analog command input, single pump specifications)
Photo coupler insulation, open collector, DC +24 V, 30 mA maximum

Specifications
Shared positive/negative common
Digital output signal (*3)
DO1 Alarm signal
(3 ch)
DO2 Pump capacity selection output (flow rate selection, analog command input specifications)
DO2, 3 (Not used, analog command input, single pump specifications)
Oil type Mineral-oil base hydraulic oil, wear resistance hydraulic oil
Oil temperature 0 to 60[°C] (Recommended operating temperature range: 15 to 50[°C])
Fluid used (*4) Viscosity grade ISO VG32 to 68
Viscosity range 15 to 400 mm2/s
Contamination Within NAS class 9
Indoors (not exposed to direct sunlight)
Atmosphere Not to be subject to corrosive gases, inflammable gases, oil mist or dust
Altitude 1,000 m maximum
Ambient humidity 85% RH maximum (no dew condensation)
Operating
environment Ambient Motor pump 0 to 40°C (no freezing)
temperature Controller 0 to 40°C (no freezing)
Installation Motor pump To be secured on the base for the hydraulic unit on the machine. To be installed horizontally
orientation Controller
To be installed inside an electrical cabinet (IP54). To be installed in the vertical orientation (with the main power supply terminals at the bottom)
Controller IP20
Protection grade
Motor (*5) IP54

Storage Motor pump −20 to +70°C (no freezing)


temperature Controller −20 to +60°C (no freezing)
Storage
environment Motor pump
Storage 85% RH maximum (no dew condensation)
humidity Controller
Power supply grounding type TN
(a) Install a no fuse breaker on the main power supply to protect electrical circuits from overcurrent, in the event of short circuits for example.
(b) Be sure to connect the ground terminals of the controller and motor pump.
Others
(c) Frequently turning the controller’s power supply ON/OFF will substantially shorten the controller’s service life.
It is advisable to start and stop the motor by turning the digital input (DI1) ON/OFF.

(*1) There are two different voltage specifications: 5 V specifications and 10 V (*3) When incorporating a relay in the circuit as a load, take necessary measures against
specifications. The PMAX and QMAX settings can be selected using parameters. surge or select a surge-resistant product.
The input and output voltage settings can be selected using parameter VMAX.
(*4) Consult DAIKIN about the use of hydraulic oils other than mineral-oil base type (e.g.
(*2) When incorporating a semiconductor relay in the circuit, select a product with a leak hydrous/synthetic) such as water-glycol hydraulic oil.
current specification of 1 mA maximum.
(*5) The shaft through hole, encoder connector, motor cooling fan and terminal block are
excluded.

Performance Specification
200 V specifications 400 V specifications
Model SUT00S / SUT00D SUT00S / SUT00D S-SUT00D S-SUT00S S-SUT00D
S3018, S5021, S5025, S8018, S13018, S15018 S5021, S8018, S13018, S13021, S15018, S20018 – S25018, S30018 –
Item
D3021, D8021, D15021, D20021 D8021,D13021, D15021 D20021 – D8025, D13025, D20025
Linearity F.S. 1[%] F.S. 1[%]
characteristics
Flow rate

Hysteresis F.S. 1[%] F.S. 1[%]


Maximum flow rate response time (*1) 0.1 [s] 0.12 [s] 0.1[s]
Repeatability F.S. 1[%] F.S. 1[%]
Linearity F.S. 1[%] F.S. 1[%]
characteristics
Pressure

Hysteresis F.S. 1[%] F.S. 1[%]


Maximum pressure response time (*2) 0.1 [s] 0.14 [s] 0.15 [s] ─
Repeatability F.S. 1[%] F.S. 1[%]

Note: The data given above are the representative performance values, not guaranteed values.
(*1) Time required to reach 95% of the commanded value in response to a command to change the flow rate from 0 to the maximum with no load applied. With S-SUT00S25018 and
S-SUT00S30018, it is the time required to reach 90% from 10% under the same condition.
(*2) Time required to reach 95% of the commanded value in response to a command to change the pressure from 0 to the maximum. The volumetric load capacity condition is 2 m of 3/4
high-pressure hose with SUT00S3018 to SUT00S13021, and 2 m of 1B high-pressure hose with SUT00S20018.
With S-SUT00S25018 and SUT00S30018, it is the time required to reach 90% from 10% under the same condition. The volumetric load capacity condition is 2 m of 1-1/2B high-pressure
hose and a 10 L cylinder with S-SUT00S25018, and 2 m of 1-1/4B high-pressure hose × 2 and a 10 L cylinder with S-SUT00S30018.
12
About Continuous and Short-time Rating Range

Analog command input/high-accuracy type SUPER UNITs can run continuously within the continuous
rating range given in the pressure - flow rate characteristic charts (see P-Q charts on pages 15 to 20).
Note, however, that the range of operation can be extended to within the short-time rating range for
up to 20 seconds (or 60 seconds for the 400 V single pump type), provided it does not exceed a 20%
duty cycle.

Example with Single Pump Type Example with Double Pump Type
SUT00S20018-20YL-N0340 SUT00D13021-10-B-N0321

Continuous Short-time
rating range rating range
250 200

200 150

Flow rate [L/min]


Combination flow - Short-time rating Independent flow -
Flow rate [L/min]

Short-time rating
150
100 Independent flow -
Continuous rating
100
50
Combination flow -
50 Continuous rating
0
0 5 10 15 20 25
0
0 5 10 15 20 Pressure [MPa]

Pressure [MPa]

Continuous rating : Continuous operation is possible when the mean hydraulic power obtained based
on the pressure and flow rate during operation of 1 cycle is lower than the hydraulic
power for the continuous rating range in the figure above and also the
root-mean-square of the load pressure is within the maximum pressure for the
continuous rating range.
(With the double pump type unit shown in the figure above with independent flow
selected, continuous operation with the pressure held at 20.6 MPa is possible.
However, for cycles that include pressure holding for 3 minutes or longer, a bleed
off circuit equivalent to the capacity of a single pump running at 150 min-1 must be
provided at the pump discharge side to cool the pump.)

Short-time rating : Operation possible for 20 seconds (or 60 seconds with 400 V single pump type)

 Reference
How to obtain the mean hydraulic power and
root-mean-square pressure (example for single pump type)

When load pressure in each process within 1 cycle is Pn (n = 1, 2, ...., n), flow rate is Qn (n = 1,
2, ...., n), and time is tn (n = 1, 2, ...., n)
 Mean hydraulic power = (P1×Q1/60×t1+P2×Q2/60×t2+...+Pn×Qn/60×tn) / (t1+t2+…+tn)
 Root-mean-square of load pressure = SQRT((P12×t1+P22×t2+...+Pn2×tn) / (t1+t2+...+tn))
(Note, however, that if the pump runs above the rated pump rotational speed of 1800 min-1 to provide the
control flow rate of Qn, with the load pressure Pn, Pn needs to be converted to the value when the pump is
running at 1800 min-1.)
When the pump capacity of the SUPER UNIT is qn [cm3], the pump rotational speed Nn is Nn = Qn×103/qn.
Therefore, converted pressure Pn = Pn×(Nn/1800)
Note 1: The procedure for obtaining the mean hydraulic power and root-mean-square pressure with flow-rate-selection
specifications (double pump type) is basically the same as above. Please consult us for detailed information.
Note 2: SQRT above represents square root operation ( ). For the continuous rating hydraulic powers for each model, see the
pressure - flow rate characteristic charts (P-Q characteristic charts) given in the instruction manual provided separately.

13
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

Command Voltage - Control Pressure /


Command Voltage - Control Flow Rate Characteristic Examples

Example with Double Pump Type (SUT00D15021-10-B)

PI-PO static characteristics QI-QO static characteristics

24 200

20
150

Flow rate [L/min]


Pressure [MPa]

16

12 100

8
Linearity ≤ 1%F.S Linearity ≤ 1%F.S
50
Hysteresis ≤ 1%F.S Hysteresis ≤ 1%F.S
4

0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Pressure command PI [V] Flow rate command QI [V]

About Continuous Rating and Short-time Rating


Command Voltage - Control Pressure / Control Flow Rate Characteristic Examples
Low-pressure control: Low flow rate control:
Minimum control pressure = 1% F.S. or higher Minimum control flow rate = 1% F.S. or higher

Example Output Characteristics for Flow Rate Selection


Specifications (SUT00D8021-30-B)

24 100
Independent Independent
20
Combination 80 Combination
Flow rate [L/min]
Pressure [MPa]

16
60
12
40
8

20
4

0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Pressure command voltage PI [V] Flow rate command voltage QI [V]

12 12
Independent Independent
10 10
Combination Combination
Output voltage Qo [V]
Output voltage Po [V]

8 8

6 6

4 4

2 2

0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Pressure command voltage PI [V] Flow rate command voltage QI [V]

Note 1: Since the PQ characteristics vary depending on the model, refer to the appropriate PQ characteristic chart for the
detailed output characteristics of each model.
Note 2: When the combination flow is selected (DI5 = ON), the pressure does not rise above 17.5 MPa even if the pressure
command voltage (Pi) is increased as shown in the graph above.

14
Pressure – Flow Rate Characteristics (Single pump type)

200 V Single Pump

PQ chart - 1 PQ chart - 2
50 100
45
40 80
Flow rate [L/min]

Flow rate [L/min]


35
30 60 Short-time rating
Short-time rating
25
20 40
15
Continuous rating
10 20 Continuous rating
5
0 0
0 5 10 15 20 0 5 10 15 20 25
Pressure [MPa] Pressure [MPa]

SUT00S3018-30-A SUT00S5021-30-A
Maximum operating pressure = 17.6 [MPa] Maximum operating pressure = 20.6 [MPa]
Maximum flow rate = 30 [L/min] Maximum flow rate = 50 [L/min]
Command voltage = 5 [V] Command voltage = 5 [V]

PQ chart - 3 PQ chart - 4
100 100

80 80
Flow rate [L/min]

Flow rate [L/min]

Short-time rating

60 60 Short-time rating

40 40

Continuous rating
20 Continuous rating 20

0 0
0 5 10 15 20 0 5 10 15 20 25 30
Pressure [MPa] Pressure [MPa]

SUT00S8018-30-A SUT00S5025-10-L-N0432
Maximum operating pressure = 17.6 [MPa] Maximum operating pressure = 24.5 [MPa]
Maximum flow rate = 80 [L/min] Maximum flow rate = 50 [L/min]
Command voltage = 5 [V] Command voltage = 5 [V]

PQ chart - 5
200

150
Flow rate [L/min]

Short-time rating

100

50 Continuous rating

0
0 5 10 15 20
Pressure [MPa]

SUT00S15018-10-A
Maximum operating pressure = 17.6 [MPa]
Maximum flow rate = 150 [L/min]
Command voltage = 5 [V]

15
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

400 V Single Pump

PQ chart - 6 PQ chart - 7
80 100
70
80
60
Flow rate [L/min]

Flow rate [L/min]


Short-time rating Short-time rating
50 60
40
30 40

20 Continuous rating
Continuous rating 20
10
0 0
0 5 10 15 20 25 0 5 10 15 20
Pressure [MPa] Pressure [MPa]

SUT00S5021-20YA-N0265 SUT00S8018-21YA
Maximum operating pressure = 20.6 [MPa] Maximum operating pressure = 17.6 [MPa]
Maximum flow rate = 50 [L/min] Maximum flow rate = 80 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]

Pressure – Flow Rate Characteristics


(Single pump)
PQ chart - 8 PQ chart - 9
200 200

150 150
Flow rate [L/min]

Flow rate [L/min]

Short-time rating
Short-time rating

100 100

50 50
Continuous rating Continuous rating

0 0
0 5 10 15 20 0 5 10 15 20 25
Pressure [MPa] Pressure [MPa]

SUT00S13018-10YA-N0218 SUT00S13021-11YA-N0286
Maximum operating pressure = 17.6 [MPa] Maximum operating pressure = 20.6 [MPa]
Maximum flow rate = 130 [L/min] Maximum flow rate = 130 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]

PQ chart - 10 PQ chart - 11
200 250

200
150
Flow rate [L/min]

Short-time rating
Flow rate [L/min]

Short-time rating

150
Continuous rating
100
100

50
Continuous rating 50

0 0
0 5 10 15 20 0 5 10 15 20
Pressure [MPa] Pressure [MPa]

SUT00S15018-10YA SUT00S20018-20YL-N0340
Maximum operating pressure = 17.6 [MPa] Maximum operating pressure = 17.6 [MPa]
Maximum flow rate = 150 [L/min] Maximum flow rate = 200 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]

16
Pressure – Flow Rate Characteristics (Single pump type)

400 V Single Pump

PQ chart - 12 PQ chart - 13
350 350

300 300
Short-time rating Short-time rating
Flow rate [L/min]

Flow rate [L/min]


250 250

200 200

150 150
Continuous rating Continuous rating
100 100

50 50

0 0
0 5 10 15 20 0 5 10 15 20
Pressure [MPa] Pressure [MPa]

S-SUT00S25018-10YA S-SUT00S30018-10YA
Maximum operating pressure = 17.6 [MPa] Maximum operating pressure = 17.6 [MPa]
Maximum flow rate = 250 [L/min] Maximum flow rate = 300 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]

17
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

Pressure – Flow Rate Characteristics (Double pump specifications)

200 V Double Pump

PQ chart - 14 PQ chart - 15
35 100
Combination flow - Short-time rating
30 Combination flow - Short-time rating Independent flow -
Independent flow - 80 Short-time rating
Flow rate [L/min]

Flow rate [L/min]


25 Short-time rating

20 Independent flow - 60
Continuous rating
15 40
Combination flow - Independent flow -
10
Continuous rating Continuous rating
20
5 Combination flow -
Continuous rating
0 0
0 5 10 15 20 25 0 5 10 15 20 25
Pressure [MPa] Pressure [MPa]

SUT00D3021-30-B-N0436 SUT00D8021-30-B-N0323
Maximum operating pressure = 17.6/20.6 [MPa] Maximum operating pressure = 17.6/20.6 [MPa]
Maximum flow rate = 30/18.3 [L/min] Maximum flow rate = 80/38.4 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]

PQ chart - 16 PQ chart - 17

Pressure – Flow Rate Characteristics


(Single/double pump)
200 200
180
Combination flow - Short-time rating Independent flow -
160
150 Short-time rating
Flow rate [L/min]

Flow rate [L/min]

Combination flow - Short-time rating Independent flow - 140


Short-time rating 120
100 Independent flow - 100
Continuous rating 80
60 Independent flow -
50
40 Combination flow - Continuous rating
Combination flow -
Continuous rating 20 Continuous rating
0 0
0 5 10 15 20 25 0 5 10 15 20 25
Pressure [MPa] Pressure [MPa]

SUT00D13021-10-B-N0321 SUT00D15021-10-B-N0365
Maximum operating pressure = 20.6/20.6 [MPa] Maximum operating pressure = 17.6/20.6 [MPa]
Maximum flow rate = 130/47.9 [L/min] Maximum flow rate = 150/70.9 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]

PQ chart - 18
250

Combination flow - Short-time rating


200
Flow rate [L/min]

Combination flow - Continuous rating


150

100 Independent flow - Continuous rating


Independent flow - Short-time rating
50

0
0 5 10 15 20 25 30
Pressure [MPa]

SUT00D20021-10-L
Maximum operating pressure = 11.5/25.0 [MPa]
Maximum flow rate = 200/56 [L/min]
Command voltage = 10 [V]

18
Pressure – Flow Rate Characteristics (Double pump specifications)

400 V Double Pump

PQ chart - 19 PQ chart - 20
100 200

Combination flow - Short-time rating Independent flow -


80
Short-time rating 150
Flow rate [L/min]

Flow rate [L/min]


Combination flow - Short-time rating
60 Combination flow - Independent flow -
Continuous rating Short-time rating
100 Combination flow -
40 Continuous rating

Independent flow - 50
20
Continuous rating Independent flow -
Continuous rating
0 0
0 5 10 15 20 25 0 5 10 15 20 25
Pressure [MPa] Pressure [MPa]

SUT00D8021-21YB-N0324 SUT00D13021-10YB-N0322
Maximum operating pressure = 17.6/20.6 [MPa] Maximum operating pressure = 20.6/20.6 [MPa]
Maximum flow rate = 80/38.4 [L/min] Maximum flow rate = 130/47.9 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]

PQ chart - 21 PQ chart - 22
200 250
180 Combination flow - Short-time rating
160 Combination flow - Short-time rating 200
Independent flow - Combination flow -
Flow rate [L/min]

Flow rate [L/min]

140 Short-time rating Continuous rating


120 150
100 Combination flow - Independent flow - Short-time rating
80 Continuous rating 100 Independent flow -
60 Continuous rating
40 50
Independent flow -
20
Continuous rating
0 0
0 5 10 15 20 25 0 5 10 15 20 25 30
Pressure [MPa] Pressure [MPa]

SUT00D15021-10YB-N0358 S-SUT00D20021-12YL
Maximum operating pressure = 17.6/20.6 [MPa] Maximum operating pressure = 11.5/25.0 [MPa]
Maximum flow rate = 150/70.9 [L/min] Maximum flow rate = 200/56 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]

PQ chart - 23 PQ chart - 24
100 200
Combination flow - Short-time rating
80
150
Flow rate [L/min]

Flow rate [L/min]

Combination flow - Short-time rating


Independent flow -
60
Independent flow - Short-time rating
Short-time rating 100
40 Combination flow - Independent flow -
Independent flow - Continuous rating Continuous rating
50
20 Continuous rating
Combination flow -
Continuous rating
0 0
0 5 10 15 20 25 30 0 5 10 15 20 25 30
Pressure [MPa] Pressure [MPa]

S-SUT00D8025-11YL S-SUT00D13025-11YL
Maximum operating pressure = 15.0/25.0 [MPa] Maximum operating pressure = 15.0/25.0 [MPa]
Maximum flow rate = 80/40.0 [L/min] Maximum flow rate = 130/37.3 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]

19
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

400 V Double Pump

PQ chart - 25 PQ chart - 26
250 350
Combination flow - Short-time rating
Combination flow - Short-time rating 300
200
Flow rate [L/min]

Flow rate [L/min]


Independent flow - 250
150 Short-time rating Combination flow - Independent flow -
200
Independent flow - Continuous rating Short-time rating
100 Combination flow - Continuous rating 150
Continuous rating
100
50
50 Independent flow -
Continuous rating
0 0
0 5 10 15 20 25 30 0 5 10 15 20 25 30
Pressure [MPa] Pressure [MPa]

S-SUT00D20025-20YL S-SUT00D30025-10YA
Maximum operating pressure = 16.5/25.0 [MPa] Maximum operating pressure = 17.5/25.0 [MPa]
Maximum flow rate = 200/56.1 [L/min] Maximum flow rate = 300/160.0 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]

Pressure – Flow Rate Characteristics


(Double pump)

20
External Dimension Diagram (Motor pump 200 V/400 V single pump type)

200 V 30 L/min 17.6 MPa


190
SUT00S3018-30-A Geared pump Suction flange IPM motor

Suction port
(Fitted with a resin
plug at shipment)

110
Pressure sensor Suction air

128

94
57

Product nameplate
Safety valve
View A-A Motor cable wiring port
Motor nameplate
Motor cooling fan wiring port
602
264
(100) Port T 412
A 154 Encoder port
(Fitted with a vinyl 351
cap at shipment)
Discharge block
251

202.5
218

(153)

(128)

112
(88)
A 95 95 4-12 (for mounting)
Port P1 42.5 114.5 140
214
(Fitted with a vinyl cap 196
at shipment)

Power supply Pump Suction Discharge Drain Pressure sensor Suction


Model code specifications specifications port port port orientation (*1) flange
SUT00S3018-30-A 200 V Single Rc1 Rc½ Rc⅜ Front Incorporated
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.

4-M10 × P1.25 (fine thread)


200 V/400 V 50 L/min 20.6 MPa Effective depth 14 IPM motor

200 V/400 V 80 L/min 17.6 MPa Suction port φ25

Geared pump

SUT00S5021-30-A
SUT00S8018-30-A
Suction air
SUT00S5021-20YA-N0265
26.2 ±0.3
129

52.4 ±0.3
SUT00S8018-21YA
D Approximate center of gravity
View A-A
Motor cooling fan, thermistor wiring port (φ21) Motor cable wiring port (φ28)

Discharge port L
321 Rc¾ 35 C 496
117 204
95.5 Relief valve 118 5 Encoder cable port
A MR-03P-3-40-56
□E

MR-03P-3-40-56
D C

NI
C

JAPAN
230

243
228

207
197
129
22.2
89

A
112

Pressure sensor Motor cooling fan


Drain port
108 108
Rc¾ Discharge port B 76.5
241 Rc¾ 4-φ14.5 holes (for fixing bolts)
A 228
(Plugged) (M12 bolts recommended)
275

SUT00S5021-20YA-N0265 with suction flange


With suction flange IPM motor
4-M10 × P1.25 (fine thread)
Effective depth 14 Geared pump
83

Suction
air
26.2 ±0.3

Suction port
121
129

Rc1 52.4 ±0.3


Product
Approximate nameplate
80
center of gravity Motor
View A-A nameplate
Motor cooling fan,
thermistor wiring port (φ21) Motor cable wiring port (φ28)

Model code Power supply Pump L A B C D Suction Discharge Drain Pressure sensor Suction
specifications specifications port port port orientation (*1) flange
SUT00S5021-30-A 200 V Single 736 156.5 80 156 80 φ25 Rc¾ Rc¾ Front None
SUT00S8018-30-A 200 V Single 750 163.5 87 169 87 φ25 Rc¾ Rc¾ Front None
SUT00S5021-20YA-N0265 400 V Single 743 163.5 80 156 80 Rc1 Rc¾ Rc¾ Front Incorporated
SUT00S8018-21YA 400 V Single 750 163.5 87 169 87 φ25 Rc¾ Rc¾ Front None
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.

21
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

* The motor pump needs to be secured horizontally on the machine or tank. Also, secure a clearance of at least 100 mm at the suction side of the motor cooling fan.
In addition, a clearance of at least 100 mm from the pump or solenoid valve is required at the exhaust side, with good ventilation assured by mounting a cover
provided with ventilation holes or other means.

200 V 50 L/min 24.5 MPa


SUT00S5025-10-L-N0432
Approximate center
Suction flange IPM motor of gravity Product nameplate
149 Geared pump

107 Suction port


(Fitted with a resin
plug at shipment)

105
Suction air
151

114
76

View A-A Discharge block Motor nameplate


Motor cable wiring port
Terminal box

Motor thermistor wiring port Motor cooling fan wiring port

735

366 Eye bolt 582


Encoder port
(148) 218 107 524
A
Port P
(Fitted with a resin
plug at shipment)
279

289
233
207

151

132
63

A Pressure sensor
127 127 4-φ14.5 holes
Motor cooling fan
(for fixing bolts)

External Dimension Diagram (Single pump)


279 76 97 228
(M12 bolts recommended)
300

Power supply Pump Suction Discharge Drain Pressure sensor Suction


Model code specifications specifications port port port orientation (*1) flange
SUT00S5025-10-L-N0432 200 V Single Rc1-¼ Rc1 — Bottom Incorporated
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.

22
External Dimension Diagram (Motor pump 200 V/400 V single pump type)

200 V 150 L/min 17.6 MPa


400 V 130 L/min 17.6 MPa, 130 L/min 20.6 MPa, 150 L/min 17.6 MPa
Approximate center of gravity
SUT00S15018-10-A F Suction port φ38
IPM motor
Product nameplate
SUT00S13018-10YA-N0218 Geared pump

±0.3
SUT00S13021-11YA-N0286

35.7
SUT00S15018-10YA

53
Suction air

126
149
69.9 ±0.3

D 4-M12 Terminal box Motor wiring port


View A-A (P = 1.75) Depth 14
Motor cooling fan
Motor cooling fan, thermistor wiring port
366 Relief valve Discharge port Rc1
MR-03P-3-40-56 Approximate center of gravity
148 218 L
101 272
Discharge block Encoder
Pressure 99 C 586
sensor E 524 connector

A □E
D C

N
C
279

288.5
JAPAN

294

232.5
260
218

IN OUT

193
149

149

132
A
127 127 B 14.5
279 Drain port Rc¾ A 96.5 228
Discharge port Rc1 300
(plugged at factory)

SUT00S13018-10YA-N0218 With suction flange


155 Suction flange IPM motor Approximate Product
center of gravity nameplate
Geared pump

Suction port Rc1-¼


87

Suction air
149

126

103 View A-A Motor Motor nameplate


Terminal box
wiring port
Motor cooling fan, thermistor wiring port Motor cooling fan

Model code Power supply Pump L A B C D E F Suction Discharge Drain Pressure sensor Suction
specifications specifications port port port orientation (*1) flange
SUT00S15018-10-A 200 V Single 858 97 63 213 110 183 163 φ38 Rc1 Rc¾ (L) None
SUT00S13018-10YA-N0218 400 V Single 850 90 55 194 103 175 155 Rc1-¼ Rc1 Rc¾ (L) Incorporated
SUT00S13021-11YA-N0286 400 V Single 850 90 55 194 103 175 155 Rc1-¼ Rc1 Rc¾ (L) Incorporated
SUT00S15018-10YA 400 V Single 858 97 63 213 110 183 163 φ38 Rc1 Rc¾ (L) None
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.

IPM motor Approximate Product nameplate


center of gravity
Suction port Geared pump
400 V 200 L/min 17.6 MPa Rc1-½
105

SUT00S20018-20YL-N0340
Suction air
103
151

57

Dedicated suction flange Motor


Terminal box cooling fan
View A-A
Motor Motor nameplate
Motor cooling fan, wiring port (φ34)
thermistor wiring port (φ21) 897 Encoder
366.5 230 667 connector
(148.5) (218)
Discharge 112 Discharge port
block
Rc1
A
288.5

MADE IN JAPAN
279.5

TUO
N

236
151
132

132
114

80
63

A
14.5 4-φ14.5 holes (for fixing bolts)
127 127 96.5 228 M12 bolts recommended
254
Pressure sensor

Power supply Pump Suction Discharge Drain Pressure sensor Suction


Model code specifications specifications port port port orientation (*1) flange
SUT00S20018-20YL-N0340 400 V Single Rc1-½ Rc1 — Bottom With dedicated part
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.

23
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

* The motor pump needs to be secured horizontally on the machine or tank. Also, secure a clearance of at least 100 mm at the suction side of the motor cooling fan.
In addition, a clearance of at least 100 mm from the pump or solenoid valve is required at the exhaust side, with good ventilation assured by mounting a cover
provided with ventilation holes or other means.

380 V 250 L/min 17.6 MPa, 300 L/min 17.6 MPa


(Full-time combination flow specifications)
S-SUT00S25018-10YA
Approximate
S-SUT00S30018-10YA center of gravity
Suction block Motor
Exhaust air
Suction Suction
Pump model
port 2 port 1

D
C
View A-A
Discharge block
Safety valve Exhaust air
B
Pressure sensor
Direction of motor rotation
Motor/AC fan terminal box
Motor/AC fan terminal box A 459 L
(For -YAR and -YLR 280 A 874
specifications)
95 181 140
361

Relief port (T3)


Unit nameplate
Rc¾
180

Discharge Discharge
20

port 1 port 2

A 4-φ15 (M14 bolts recommended) 125 80


279 Encoder terminal box
90 445
358

S-SUT00S25018-10YA (R) (Specifications with terminal box at the left side, viewed from the pump)

External Dimension Diagrams (Single pump)


459
280

A 99 157
Suction port
Rc 2
OIL HYDRAULIC PUMP

MOD NO PDK03156-**
DAIKIN HYDRAULICS(SUZHOU)CO.,LTD.
361

Drain port
Rc¾
180

View A-A Discharge port 1


Rc1-½
20

A 4-φ15 (M14 bolts recommended) 125


279 90

358

Model code Power supply Pump L A B C D Suction Suction Discharge Discharge Drain Pressure sensor Suction
specifications specifications port 1 port 2 port 1 port 2 port orientation (*1) flange
S-SUT00S25018-10YA 380 V Single 1246 372 201 178 118 Rc2 — Rc1-½ — Rc¾ Top Incorporated
S-SUT00S30018-10YA 380 V Single 1405 531 360 175 115 Rc2 Rc1-½ Rc1-¼ Rc1-¼ Rc¾ Top Incorporated
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.

24
External Dimension Diagram (Motor pump 200 V/400 V double pump type)

200 V 30 L/min 20.6 MPa


SUT00D3021-30-B-N0436

180
Geared pump Suction flange Motor

Suction port
(Fitted with a resin plug at shipment)

110
Suction air
Pressure sensor

115
128

57

Product nameplate

View A-A Motor cable wiring port


Motor nameplate
Motor cooling fan wiring port

264 592

154 412

Solenoid valve Encoder port


KSOB-G02-9AP Port T2 351
A (Fitted with a resin
plug at shipment)
Port P1
(Fitted with a resin
plug at shipment)
T
251

218

202.5
153

112
95

95 95 4-12 (for mounting)


156 140
214 Discharge block
157

196

Power supply Pump Discharge Return Pressure sensor Suction


Model code specifications specifications Suction port port port (T2) orientation (*1) flange
SUT00D3021-30-B-N0436 200 V Double Rc1 Rc½ Rc⅜ Front Incorporated
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.

25
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

* The motor pump needs to be secured horizontally on the machine or tank. Also, secure a clearance of at least 100 mm at the suction side of the motor cooling fan.
In addition, a clearance of at least 100 mm from the pump or solenoid valve is required at the exhaust side, with good ventilation assured by mounting a cover
provided with ventilation holes or other means.

200 V 80 L/min 20.6 MPa


400 V 80 L/min 17.6 MPa
SUT00D8021-30-B-N0323 Suction port Rc1–¼
With suction flange IPM motor
Geared pump
SUT00D8021-21YB-N0324

99
Suction air

129

136
SOLb

89

View A-A Approximate center of gravity Product nameplate


Motor nameplate

Motor cooling fan, thermistor wiring port (φ21) Motor cable wiring port (φ28)

Drain port Rc¾


(plugged at factory)
333 Solenoid valve 703
117 210 KSO-G03-20BP-20-EN
207 496
Pressure 112
sensor 89 Encoder cable
port
A
338

JAPAN
MADE IN
228

243
207
IN OUT
179
179

129
129

A Drain port Rc¾


108 108
Motor cooling fan
112
241 Discharge port Rc1 4-φ14.5
(plugged at factory) 117
Discharge port Rc1 163.5 228
275

Power supply Pump Suction Discharge Drain Pressure sensor Suction


Model code specifications specifications port port port orientation (*1) flange
SUT00D8021-30-B-N0323 200 V Double Rc1-¼ Rc1 Rc¾ (L) Incorporated
SUT00D8021-21YB-N0324 400 V Double Rc1-¼ Rc1 Rc¾ (L) Incorporated
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.

External Dimension Diagram (Double pump)


200 V 130 L/min 20.6 MPa, 150 L/min 20.6 MPa
400 V 130 L/min 20.6 MPa, 150 L/min 20.6 MPa
SUT00D13021-10-B-N0321 Suction flange IPM motor Approximate Product
center of gravity nameplate
SUT00D15021-10-B-N0365 Geared pump

SUT00D13021-10YB-N0322 Suction port


SUT00D15021-10YB-N0358
99

Suction air
149

136

SOLb

D
F Motor
View A-A
Terminal box nameplate Motor
Motor cooling fan, thermistor wiring port cooling fan
Solenoid valve Motor wiring port
366 KSO-G03-20BP-20-EN Discharge port Rc1
Approximate center of gravity
148 218 L
112 C 586
Discharge block
Pressure 89 E
sensor Encoder
A connector
358

288.5

JAPAN
279

232.5
231

IN OUT
218

199

149
149

132
104

A 127 127 B 14.5


Drain port Rc¾
279 A 96.5 228
Discharge port Rc1 300
(plugged at factory)

Model code Power supply Pump L A B C D E F Suction Discharge Drain Pressure sensor Suction
specifications specifications port port port orientation (*1) flange
SUT00D13021-10-B-N0321 200 V Double 806 169 31 220 103 131 169 Rc1-¼ Rc1 Rc¾ (L) Incorporated
SUT00D15021-10-B-N0365 200 V Double 815 177 39 228 110 139 177 Rc1-½ Rc1 Rc¾ (L) Incorporated
SUT00D13021-10YB-N0322 400 V Double 703 169 31 220 103 131 169 Rc1-¼ Rc1 Rc¾ (L) Incorporated
SUT00D15021-10YB-N0358 400 V Double 815 177 39 228 110 139 177 Rc1-½ Rc1 Rc¾ (L) Incorporated
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.

26
External Dimension Diagram (Motor pump 200 V/400 V double pump type)

200 V 200 L/min 20.6 MPa


400 V 200 L/min 20.6 MPa, 130 L/min 25 MPa
IPM motor Approximate
SUT00D20021-10-L Suction port 1 Rc1-¼ Geared pump center of gravity Product nameplate
162.7 Suction port 2 Rc1-¼
S-SUT00D20021-12YL
S-SUT00D13025-11YL

105
Suction air

103
C

99
151
E
Motor cooling fan
D Motor nameplate
Suction flange Terminal box
Motor wiring port
View A-A Motor cooling fan, thermistor wiring port

Approximate center of gravity


366 L
Discharge
148 218 586
Pressure block
sensor 81
Encoder connector

288.5
JAPAN
279
288

232.5
240
151

132
113.6

A
127 127 B 4-φ14.5 holes (for fixing bolts)
279 A 96.5 228 M12 bolts recommended
Discharge port 2 Rc1
300
Discharge port 1 Rc1

S-SUT00D13025-11YL (Pump unit, suction flange, 1 port)


Suction flange
IPM motor Approximate
Suction port 1 Rc1-¼ Geared pump center of gravity Product nameplate
105
103
151

99

Motor cooling fan


59 Motor nameplate
Terminal box
Motor wiring port
View A-A AC fan, motor thermistor wiring port

Model code Power supply Pump L A B C D E Suction Suction Discharge Drain Pressure sensor Suction
specifications specifications port 1 port 2 port port orientation (*1) flange
Incorporated
SUT00D20021-10-L 200 V Double 814 131.6 68.6 232 131.6 68.6 Rc1-¼ Rc1-¼ Rc1 Rc1 Top (2 pcs.)
Incorporated
S-SUT00D20021-12YL 400 V Double 819 131.6 68.6 232 131.6 68.6 Rc1-¼ Rc1-¼ Rc1 Rc1 Top (2 pcs.)
S-SUT00D13025-11YL 400 V Double 799 116 59 212 — 59 Rc1-¼ — Rc1 Rc1 Top Incorporated
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.

IPM motor Motor cooling fan


400 V 80 L/min 25 MPa
Suction port Rc1-¼
S-SUT00D8025-11YL
105

Suction air
98
103
131.1

113
91.1

95.6
Approximate Product nameplate
226.5 Geared pump center of gravity
Motor nameplate
View A-A Terminal box
Motor cooling fan, thermistor wiring port (φ21) Motor cable wiring port (φ28)
Discharge port Rc¼
(plugged at factory) 722.6
321 496
117 204 Encoder connection
226.5 5 Connector
A 185.2
Discharge
95.6
block
MADE IN JAPAN

Discharge
block
243
228

OUT
N

207
131.1
94

Pressure
A
sensor
108 108 Discharge port PH 228 4-φ14.5 holes (for fixing bolts)
241 Rc1 275 M12 bolts recommended
Discharge port PL
Rc1
Power supply Pump Suction Discharge Discharge Pressure sensor Suction
Model code specifications specifications port port PH orientation (*1) flange
port PL
S-SUT00D8025-11YL 400 V Double Rc1-¼ Rc1 Rc1 Bottom Incorporated
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.

27
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

* The motor pump needs to be secured horizontally on the machine or tank. Also, secure a clearance of at least 100 mm at the suction side of the motor cooling fan.
In addition, a clearance of at least 100 mm from the pump or solenoid valve is required at the exhaust side, with good ventilation assured by mounting a cover
provided with ventilation holes or other means.

400 V 200 L/min 25 MPa


S-SUT00D20025-20YL Approximate
IPM motor center of gravity Product nameplate
Geared pump 65

Suction port Rc1-½

105
Suction air

103
99
151

65

Dedicated suction flange Terminal box


Motor
View A-A Motor wiring port (φ34) nameplate Motor cooling fan
Motor cooling fan, thermistor wiring port (φ21)

896
366.5 228 667 Encoder connector
(148.5) (218) 128
Pressure
sensor 65

A
279.5
288.5

236
151

132
114

Discharge port PH Rc1 14.5

7
127 127 Discharge port PL Rc1 96.5 228 4-φ14.5 holes
(for fixing bolts)
254 M12 bolts recommended
Discharge block

Power supply Pump Discharge Discharge Pressure sensor


Model code specifications specifications Suction port port PH orientation (*1) Suction flange
port PL
S-SUT00D20025-20YL 400 V Double Rc1-½ Rc1 Rc1 Bottom With dedicated part
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.

External Dimension Diagram (Double pump)


380 V 300 L/min 25 MPa
S-SUT00D30025-10YA
Approximate
center of gravity
Suction flange Motor Exhaust air
Suction port 2 (T2) Suction port 1 (T1) Pump
Rc1-½ model
Rc 2
D
C

View A-A
Discharge block
Safety valve
360
Pressure sensor
Direction of motor rotation
Motor/AC fan terminal box
A
459 1405
Motor/AC fan terminal box
280 531 874
(For -YAR and -YLR
specifications) 95 181 140
361

Drain port Unit nameplate


Rc¾
180

Discharge port 1 Discharge port 2


20

Rc1-¼ Rc1-¼

A 4-φ15 125 80
279 445 Encoder terminal box
(M14 bolts recommended) 90
358

Power supply Pump Suction Suction Discharge Discharge Pressure sensor Suction
Model code specifications specifications port 1 port 2 port 1 port 2 Drain port orientation (*1) flange
S-SUT00D30025-10YA 380 V Double Rc2 Rc1-½ Rc1-¼ Rc1-¼ Rc¾ Top Incorporated
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.

28
External Dimension Diagram (Controller 200 V/400 V single/double pump type)

200 V, 30 to 200 L/min, 17.6 MPa, 20.6 MPa, 24.5 MPa (Single/double pump)
400 V, 50 to 200 L/min, 17.6 MPa, 20.6 MPa, 24.5 MPa (Single/double pump)

SUT00S3018-30-A SUT00S5021-20YA-N0265 SUT00D3021-30-B-N0436 SUT00D8021-21YB-N0324


SUT00S5021-30-A SUT00S8018-21YA SUT00D8021-30-B-N0323 SUT00D13021-10YB-N0322
SUT00S8018-30-A SUT00S13018-10YA-N0218 SUT00D13021-10-B-N0321 SUT00D15021-10YB-N0358
SUT00S5025-10-L-N0432 SUT00S13021-11YA-N0286 SUT00D15021-10-B-N0365 SUT00D20021-12YL
SUT00S15018-10-A SUT00S15018-10YA SUT00D20021-10-L

Cooling fan
View A-A (bottom face)

Vent

180
φ8 (M6 mounting bolt recommended)
Cooling fan
10

exhaust air
Monitor display

34
I/O terminal block (Normally showing the pressure in MPa)
M3 screws
FG
FG
+5V
GND
Z-
Setting keys (four keys)
Z+
B-
B+
A-
A+
THM-
THM+

Product nameplate
AGND
AO2
(QO)AGND
AO1
(PO)
AGND
AIN2
(QI) AGND
AIN1
(PI) AGND
P_S
233

A5V
ALM_C
ALM_B
ALM_A
DOCOM
DO7
DO6
DO5
DO4
DO3
361
H1

DO2

H2
DO1
DI8
DI7
DI6
DI5
DI4
DI3
DI2
DI1
DICOM
DGND
RxD
TxD
FG
FG

Controller nameplate

L1 L2 L3 P1 P2 B1 B2 U V W
95.5

Main circuit terminal block


M6 screws
— —
↑ ↑ Cooling fan
17
6

A A suction air

25 180 (25) 38.8

230 207
M6 screw
(for ground connection)
240 212

Power supply Pump


Model code H1 H2
specifications specifications
SUT00S3018-30-A
SUT00S5021-30-A 377 326
SUT00S8018-30-A 200 V Single
SUT00S5025-10-L-N0432
379 328
SUT00S15018-10-A
SUT00S5021-20YA-N0265
SUT00S8018-21YA 377 361
SUT00S13018-10YA-N0218 400 V Single
SUT00S13021-11YA-N0286
379 328
SUT00S15018-10YA
SUT00D3021-30-B-N0436
377 326
SUT00D8021-30-B-N0323
SUT00D13021-10-B-N0321 200 V Double
SUT00D15021-10-B-N0365 379 328
SUT00D20021-10-L
SUT00D8021-21YB-N0324 377 326
SUT00D13021-10YB-N0322
400 V Double
SUT00D15021-10YB-N0358 379 328
SUT00D20021-12YL

29
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

* The controller needs to be mounted vertically on a wall inside the electrical cabinet, with a clearance of at least 100 mm
secured above and below and a clearance of at least 30 mm for wiring and maintenance at the left and right.

400 V 200 L/min 17.6 MPa (Single pump)

SUT00S20018-20YL-N0340
Cooling fan
View A-A (bottom face)

Vent

I/O terminal block


M3 screws 4-φ8 holes for fixing bolts
(M6 bolts recommended)
Monitor display Cooling fan
(Normally showing the exhaust air
11

pressure in MPa)

25
FG
Setting keys (four keys)
FG
GND
+5V
Z-
Z+
B-
B+
A-
A+
THM-
THM+
AGND
AO2
(QO)AGND
AO1

Product nameplate
(PO)

AGND
AI2
(QI) AGND

236.5
AI1
(PI) AGND
P_S
A5V
ALM_C
ALM_B
ALM_A
DOCOM
DO7
DO6
DO5
DO4
DO3

DO2
DO1
DI8
DI7
415
398

371
DI6
DI5
DI4
DI3
DI2
DI1
DICOM
DGND
RxD
TxD
FG
FG

TOKYO JAPAN
L1 L2 L3 P1 P C U V W

TS-808B
137

DAIKIN
PMCAMB2A□-10
MFG No.::
****-**-******

400V
INPUT : 3PH 380-440V 50/60Hz 37.5A
:
:
MASS : kg
DAIKIN INDUSTRIES, LTD. MADE IN JAPAN

M8 screws
(For grounding)
— —
↑ ↑ Cooling fan
A 17 226 (17) A 42

19
(6)

suction air
260 238
270 240

Controller nameplate

Power supply Pump


Model code specifications specifications
SUT00S20018-20YL-N0340 400 V Single

400 V 80 L/min 25 MPa, 130 L/min 25 MPa (Double pump)

S-SUT00D8025-11YL

External Dimension Diagrams (Controller)


Cooling fan
View A-A (bottom face)
S-SUT00D13025-11YL

Vent

I/O terminal block Cooling fan


180 φ8 (M6 mounting bolt recommended) exhaust air
M3 screws
10

Monitor display
34

(Normally showing
FG
FG
GND
the pressure in MPa)
+5V
Z-
Z+
B-
B+
A-
A+
THM-
THM+
AGND
AO2
(QO)AGND
AO1
(PO)

AIN2
AGND
(QI) AGND
AIN1
(PI) AGND
Setting keys (four keys)
Hp

P_S

Product nameplate
A5V
ALM_C
ALM_B
ALM_A
DOCOM
DO7
DO6
DO5
DO4
H2

DO3
H1
Ht

DO2
DO1
DI8
DI7
DI6
DI5
DI4
DI3
DI2
DI1
DICOM
DGND
RxD
TxD
FG
FG

L1 L2 L3 P1 P2 B1 B2 U V W
95.5

DAIKIN
PMCAMA1A-10
MFG No.:: ******-******
Main circuit
400V
INPUT : 3PH 380-440V 50/60 Hz A
:
:

terminal block
MASS : kg
MADE IN JAPAN

M6 screws
— —
↑ ↑
6

17

Cooling fan
A 25 180 (25) A 38.8
Controller nameplate suction air
230 207
240 212

M6 screw (for ground connection)

Power supply Pump H1 H2 Ht Hp


Model code specifications specifications
S-SUT00D8025-11YL 377 326 361 233
400 V Double
S-SUT00D13025-11YL 379 328 363 235

30
External Dimension Diagram (Controller 400 V single/double specifications)
* The controller needs to be mounted vertically on a wall inside the electrical cabinet,
with a clearance of at least 100 mm secured above and below and a clearance of at
least 30 mm for wiring and maintenance at the left and right.

400 V 200 L/min 25 MPa (Double pump)


View A-A (bottom face)
Cooling fan
S-SUT00D20025-20YL

Vent

I/O terminal block


M3 screws 4-φ8 holes for fixing bolts Monitor display
(M6 bolts recommended) (Normally showing Cooling fan
exhaust air
11

the pressure in MPa)

25
Setting keys (four keys)
FG
FG
GND
+5V
Z-
Z+
B-
B+
A-
A+
THM-
THM+
AGND
AO2
(QO)AGND
AO1
(PO)
AGND
AI2

236.5
(QI) AGND
AI1
(PI) AGND
P_S
A5V
ALM_C
ALM_B
ALM_A
DOCOM
DO7
DO6
DO5
DO4
DO3

DO2
415
398

DO1

371
DI8
DI7
DI6
DI5
DI4
DI3
DI2
DI1
DICOM
DGND
RxD
TxD
FG
FG

TOKYO JAPAN
TS-808B
137

DAIKIN
PMCAMB2A□-10
MFG No.::
****-**-******

V
INPUT : 3PH 380-440V 50/60 Hz A
:
:
MASS : kg
MADE IN JAPAN

M8 screws (left/right)
(For grounding)
— —
↑ ↑
A Cooling fan
(6)

17 (17) A

19
226 42 suction air
260 238
270 240

Controller nameplate Model code Power supply Pump


specifications specifications
S-SUT00D20025-20YL 400 V Double

380 V 250 L/min 17.6 MPa, 300 L/min 17.6 MPa (Single pump)
380 V 300 L/min 25 MPa (Double pump)
Wiring port (power supply, regenerative brake unit)
S-SUT00S25018-10YA Wiring port (motor side)
Vent U V W Signal line wiring port
S-SUT00S30018-10YA
S-SUT00D30025-10YA

PE R S T P1 P+ N-
Cooling fan
View A-A (bottom face)

4-φ9 holes (for fixing bolts)


(M8 bolts recommended) Cooling fan exhaust D

Display
Setting keys
Hp
Ht
H

(four keys)

— Cooling fan suction —


↑ ↑
Wt
A A
W

Power supply Pump


Model code specifications specifications H Ht Hp W Wt D
S-SUT00S25018-10YA 380 V Single 570 554 535 378 300 319
S-SUT00S30018-10YA 380 V Single 610 590 565 388 250 332
S-SUT00D30025-10YA 380 V Double 610 590 565 388 250 332

31
ss

it
un
rne
This is a list of electrical components required for SUPER UNITs.

ha

ke
r
ss
The list shows the model code and quantity for each of the electrical

ra
nso
rne
r

eb
components that are contained in each set model code, that need to be

r
e
re

ha

tiv
re

ilte

ce e

cto
r
co
ordered separately, and that are contained in each S-SUT model code.

es
co

era
ef

an tiv
de

sur
ite

rea
g

is

en
s
co

ist ra
rr

g
No

Re
En
(*1) Electrical component model code fields marked with (*1) show a part

Rin

DC
Pre
Fe

res gene
Re
code instead of a model code.
(*2) Rows assigned a set model code show the electrical components among those
required for the SUPER UNIT that are contained in the set, and the quantity of
each component. Please order them separately from the SUPER UNIT.
(*3) Rows with the indication “To be ordered separately” show the electrical
components that are required, in addition to the electrical components
contained in the set, to satisfy electromagnetic compatibility (EMC).
Please order them separately.

Specifications
(*4) Rows with the indication “Electrical components provided with the product” show

0.5 mH, 55 A
1.9 mH, 27 A
1.0 mH, 55 A
30 A, M6 terminal
30 Ω, 500 W
60 Ω, 500 W
10 Ω, 500 W
20 Ω, 500 W
68 Ω, 500 W
8Ω, 4.5 kW
85 A
5 m, with ferrite core 1T
5 m, with ferrite core 2T
5 m, with ring core 3T
5 m, with ring core
10 m, with ring core
5 m, with ring core
9-pin, 5 m
12-pin, 5 m
9-pin, 10 m
5m
50 A
60 A, Soshin Electric Co.,Ltd.
Okaya Electric Industries Co.,Ltd.
75 A, FN3011-75-62
50 A, FN3025HP-50-72
the electrical components that are provided as accessories to a product ordered φ74 × φ46
by specifying an S-SUT model code. To satisfy electromagnetic compatibility
(EMC), electrical components shown in the corresponding “To be ordered
separately” row in the table will be required, so please order them separately.
(*5) Noise filter PM-SNF04 can be ordered in place of PM-SNF02.
(*6) The regenerative resistors (2 pcs.) of SUT00S5025-10-L-N0432 are 1 kW
specifications. When using the unit for applications with high regenerative

model code
load factors, additional regenerative resistors will be required.

Electrical component
Electrical component ordering
SUT (S-SUT) Model code

PM-SDL03
PM-SDL04
PM-SDL05
PM-SDL06
PM-RB02
PM-RB03
PM-RB04
PM-RB05
PM-RB06
SB-PP03159-05 (*1)
SB-PP03158-03 (*1)
PM-SPH05
PM-SPH05-001
PM-SPH05-002
PM-SPH05-003
PM-SPH10
SB-PP03151-01 (*1)
PM-SEH05-P22-A09R
PM-SEH05-P22-A12R
PM-SEH10-P22-A09R
SB-PP03706-01 (*1)
PM-SNF01
PM-SNF02
PM-SNF03
PM-SNF04
PM-SNF07
PM-SRC01
PM-SRC02
SB-PP03404-02 (*1)
PM-FC01
PM-FC04
PM-FC05

classification/set model code (*2)


SUT00S3018-30-A Model code for set order PM-SOP15 1 2 1 1 1 1 1
SUT00S5021-30-A
Model code for set order PM-SOP16 1 3 1 1 2 1 1
SUT00S8018-30-A
SUT00S5025-10-L-N0432 Electrical components provided with the product (*4) 1 2 (*6) 1 1 2 1 1 1 1

200 V
List of Electrical Components

Model code for set order PM-SOP10 1 6 1 1 (*5)


SUT00S15018-10-A
To be ordered separately (*3) 2 or 2 1 1 1 1

SUT00S5021-20YA-N0265 Model code for set order PM-SOP04 1 2 1 1


SUT0S8018-21YA To be ordered separately (*3) 1 3 1
SUT00S13018-10YA-N0218 Model code for set order PM-SOP08 1 4 1 1
SUT00S13021-11YA-N0286

Single pump type


SUT00S15018-10YA To be ordered separately (*3) 1 1 2 3

400 V
Model code for set order PM-SOP12 1 6 1 1
SUT00S20018-20YL-N0340
To be ordered separately (*3) 2 2 2
S-SUT00S25018-10YA Electrical components provided with the product (*4) 1 1 1 1 1 1
S-SUT00S30018-10YA Electrical components provided with the product (*4) 1 1 1 1 1 1
SUT00D3021-30-B-N0436 Model code for set order PM-SOP15 1 2 1 1 1 1 1
SUT00D8021-30-B-N0323 Model code for set order PM-SOP16 1 3 1 1 2 1 1

200 V
SUT00D13021-10-B-N0321 Model code for set order PM-SOP10 1 6 1 1 (*5)
SUT00D15021-10-B-N0365
SUT00D20021-10-L To be ordered separately (*3) 2 or 2 1 1 1 1
Model code for set order PM-SOP04 1 2 1 1
SUT00D8021-21YB-N0324
To be ordered separately (*3) 1 3 1

SUT00D13021-10YB-N0322 Model code for set order PM-SOP08 1 4 1 1


SUT00D15021-10YB-N0358 To be ordered separately (*3) 1 1 2 1 3

S-SUT00D20021-12YL Electrical components provided with the product (*4) 1 4 1 1


S-SUT00D13025-11YL To be ordered separately (*3) 1 1 2 3

Double pump type


400 V
Electrical components provided with the product 1 2 1 1
S-SUT00D8025-11YL
To be ordered separately (*3) 1 3 1
Electrical components provided with the product (*4) 1 6 1 1
S-SUT00D20025-20YL
To be ordered separately (*3) 2 2 2
S-SUT00D30025-10YA Electrical components provided with the product (*4) 1 1 1 1 1 1
SUPER UNIT
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

32
List of Electrical Components/External Dimension Diagrams (Controller)
33
Ring core (2 turns)
SUPER UNIT controller *1 Filter board *1 Filter board *1
M3

1 L1
FG S L1 S L1
25 L2
FG R L2 R L2
2 L3
GND T L3 T L3
26 E
+5V PE PE
3
Z-
27
Z+ Encoder
4
B-
28 200 V 50 Hz, 200/220 V 60 Hz
0.3 mm2 (AWG 22) or greater B+
5 0.5 mm2 (CE cable) Max. 23.2 kVA
A-
29 0.5 mm2 (VCT cable) Recommendation Breaker capacity 50 A
A+
6 Power supply cable 6 mm2 (CE cable)
THM+ Motor
30 2.0 mm2 (CE cable) 8 mm2 (VCT cable)
THM- thermistor
7 1.5 mm2 (VCT cable)
AGND M6
* Flow rate monitor 31 Flow rate monitor Regenerative resistor*2 L1
QO
8 (30 Ω × 3) 200 V 50 Hz
AGND L2
* Pressure monitor 32 Pressure monitor 200/220 V 60 Hz
PO E
9
AGND
Flow rate command 33 Flow rate command L1
QI Main power
10 L2
AGND supply
Pressure command 34 Pressure command L3
PI DC AC FAN
11 DC P1
AGND reactor AC
Reactor P2 *2 SUPER UNIT motor pump
35 FAN
P_S Pressure sensor
12 Regenerative B1
+5V resistance
36 B2
ALM_C When power OFF, at alarms U
13 U
Alarm monitoring ALM_B ALM_B V
37 During normal operation Motor V
ALM_A W M
ALM_A W
0.3 mm2 (AWG22) 14
DOCOM(0V)
or more 38
DO7
15 THM
DO6
39 Th
Controller at Ferrite core *1 DO5
16 Unassigned 2
the machine side 4 mm (CE cable)
Controller side, DO4
40 5.5 mm2 (VCT cable)
simultaneous DO3
clamping of 17 1 A+
DO2
Operation possible thermistor and 41 2 A-
encoder DO1
without the items 18
DI8 3 B+
marked with *
42 4 B-
DI7
19 5 Z+
DI6 Encoder
43 6 Z-
DI5 Unassigned
20 7 +5V
DI4
44 8 GND
DI3
21 9 FG
DI2
45
* Motor DI1 Start/stop (Open: automatic control)
start/stop 22
DICOM (+24 V) AGND
46 1
DGND P_S
* Serial 23 2 Pressure Pump
RXD For Hybrid-Win +5V sensor
communication 47 3 model
TXD
0.3 mm2 (AWG22) 24
FG
or more 48
FG

0.3 mm2 (AWG22) or more

Ring core
(5 turns)
(Provided at the pressure sensor side of the pressure sensor harness)
Electric Wiring Diagram (Example with 200 V single pump type SUT00S5021 and SUT00S8018)
M3 SUPER UNIT controller
Noise filter
25
FG
2 R
GND 4 1
26 S
+5V 5 2
3 T
Z- 6 3
27 E
Z+ Encoder
4 *1 *1
B-
28 Ring core 2 (2 turns)
2
0.3 mm (AWG22) or more B+ (At the controller side) 3-phase AC 380 to 440 V
5
A- ,50 Hz/60 Hz
29 *1
A+ *1 Ring core 1 (5 turns)
Ferrite core Max. 34.8 kVA
6 (At the AC fan side)
THM- Motor thermistor Recommendation Breaker capacity 40 A
30 (At the controller side)
THM+ (No polarity)
7 Power supply cable
AGND Regenerative R 6 mm2 (70°C cable)
* Flow rate monitor 31 Flow rate monitor
QO resistance N 14 mm2 (60°C cable)
8 (68 Ω × 4)
AGND E
* Pressure monitor 32 Pressure monitor
PO M6
9
AGND 1-phase AC 215 to 245 V
Flow rate command 33 Flow rate command
QI ,50 Hz/60 Hz
10 1 2
AGND 0.5 mm (70°C cable)
Pressure command 34 Pressure command L1
PI Main power 2 0.5 mm2 (60°C cable)
1 supply L2
FG 3
11 L3
AGND 4 AC FAN
35 P1 DC
P_S Pressure sensor DC reactor 5 reactor *2 AC
12 P2
+5V 6 FAN SUPER UNIT motor pump
36 Regenerative B1
ALM_C resistance 7
13 B2
Alarm signal ALM_B When power OFF, at alarms 8 U
37 U
ALM_A ALM_B 9 V
Motor wiring V
14 During normal operation 10 W
DOCOM (0V) M
38 ALM_A W
DO7
15
0.3 mm2 (AWG 22) DO6
39 THM
Machine side or greater DO5
16 *1 *1 Th
controller DO4 Warning output Ferrite core Ferrite core
40
DO3 (At the controller side) (At the motor
17 side)
DO2
Operation possible 41
DO1 Ready to operate *1 1 A+
without the items 18
DI8 Ring core 2 (2 turns)
marked with * 2 A-
42 (At the controller side)
DI7 3 B+
19
DI6 4 B-
43 10 mm2 (70°C cable)
DI5 14 mm2 (60°C cable) 5 Z+
20 Encoder
DI4 6 Z-
44
DI3 7 +5V
21
DI2 8 GND
45
DI1 Start/stop (Set in start status upon input of DC 24 V power) FG
Motor start/stop 22 9
DICOM (DC+24 V)
46
DGND
23 AGND
*Serial communication RXD For servicing 1
47 P_S Pressure
TXD 2 Pump
2
0.3 mm (AWG 22) 24 +5V sensor model
FG 3
or greater 48
FG
Electric Wiring Diagram (Example with 400 V single pump type SUT00S13018)

0.3 mm2 (AWG22) or more

Ring core 1
(3 turns)
(At the pressure sensor side)
SUPER UNIT
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

Electric Wiring Diagram

34
35
Ring core (2 turns)
SUPER UNIT controller *1 Filter board *1 Filter board *1
M3

1 L1
FG S L1 S L1
25 L2
FG R L2 R L2
2 L3
GND T L3 T L3
26 E
+5V PE PE
3
Z-
27
Z+ Encoder
4
B-
28 200 V 50 Hz, 200/220 V 60 Hz
0.3 mm2 (AWG 22) or greater B+
5 0.5 mm2 (CE cable) Max. 23.2 kVA
A-
29 0.5 mm2 (VCT cable) Recommendation Breaker capacity 50 A
A+
6 Power supply cable 6 mm2 (CE cable)
THM+ Motor 2
30 2.0 mm (CE cable) 8 mm2 (VCT cable)
THM- thermistor
7 1.5 mm2 (VCT cable)
AGND M6
* Flow rate monitor 31 Flow rate monitor Regenerative resistance*2 L1
QO
8 (30 Ω × 3) 200 V 50 Hz
AGND L2
* Pressure monitor 32 Pressure monitor 200/220 V 60 Hz
PO E
9
AGND
Flow rate command 33 Flow rate command L1
QI Main power supply
10 L2
AGND
Pressure command 34 Pressure command L3
PI AC FAN
11 DC P1 DC
AGND Reactor AC SUPER UNIT motor pump
35 P2 reactor *2
P_S Pressure sensor FAN
12 Regenerative B1
+5V resistance
36 B2
ALM_C When power OFF, at alarms U
13 U
Alarm monitoring ALM_B ALM_B V
37 During normal operation Motor V
ALM_A W M
ALM_A W
0.3 mm2 (AWG22) 14
DOCOM(0V)
or more 38
DO7
15 THM
DO6
39 Th
Machine side Ferrite core *1 DO5
16 4 mm2 (CE cable)
controller Controller side DO4
simultaneous clamping 40 5.5 mm2 (VCT cable)
DO3
of thermistor and encoder 17 1 A+
DO2
Operation possible 41 2 A-
DO1 Ready to operate
without the items 18
DI8 3 B+
marked with *
42 4 B-
DI7
19 5 Z+
DI6 Encoder
43 6 Z-
DI5 Pump capacity selection input
20 7 +5V
DI4
44 8 GND
DI3
21 9 FG
DI2
45
DI1 Start/stop (Open: automatic control)
* Motor start/stop 22
DICOM (+24 V)
46 1 AGND
DGND P_S
* Serial 23 2 Pressure Pump
communication RXD For Hybrid-Win +5V sensor
47 3 model
TXD
0.3 mm2 (AWG22) 24
FG
or more 48
FG
(Provided at the
pressure sensor side
of the pressure
0.3 mm2 (AWG 22) or greater sensor harness) SOL+
Solenoid valve
Electric Wiring Diagram (Example with 200 V double pump type SUT00D8021)

Ring core SOL-


SOL DC+24V (5 turns)
SUPER UNIT controller
M3
Noise filter
25
FG
2 R
GND 4 1
26 S
+5V 5 2
3 T
Z- 6 3
27 E
Z+ Encoder
4 *1 *1
B-
28 Ring core 2 (2 turns)
0.3 mm2 (AWG 22) or greater B+ (At the controller side) 3-phase AC 380 to 440 V
5
A- , 50 Hz/60 Hz
29 *1
A+ *1 Ring core 3 (5 turns)
Ferrite core Max. 34.8 kVA
6 (At the AC fan side)
THM+ Motor thermistor Recommendation Breaker capacity 40 A
30 (At the controller side)
THM- (No polarity)
7 Power supply cable 6 mm2 (CE cable)
AGND Regenerative R
* Flow rate monitor 31 Flow rate monitor 14 mm2 (VCT cable)
QO resistance N
8 (68 Ω × 4)
AGND E
* Pressure monitor 32 Pressure monitor
PO M6
9
AGND 1-phase AC 215 to 245 V
Flow rate command 33 Flow rate command
QI , 50 Hz/60 Hz
10 1 2
AGND 0.5 mm (CE cable)
Pressure command 34 Pressure command L1
PI 2 0.5 mm2 (VCT cable)
1 L2
FG 3
11 L3
AGND 4 AC FAN
35 P1 DC
P_S Pressure sensor DC reactor 5 reactor *2 AC
P2 SUPER UNIT
12 6 W
+5V Ferrite core *1 FAN motor pump
36 B1
ALM_C Regenerative resistance 7 (At the motor side)
13 B2
Alarm signal ALM_B When power OFF, at alarms 8 U
37 U
ALM_A ALM_B 9 V
Motor wiring V
14 During normal operation 10 W
DOCOM M
38 ALM_A W
0.3 mm2 (AWG 22) DO7
or greater 15
DO6
39 THM
Machine side DO5
16 *1 Th
controller DO4 Warning output Ferrite core
40
DO3 Pump capacity selection output (At the controller side)
17
DO2
Operation possible 41
DO1 Ready to operate *1
without the items 18 Ring core 2 (2 turns) 1 A+
marked with * DI8 2
42 (At the controller side) A-
DI7 3
19 B+
DI6 4
43 10 mm2 (CE cable) B-
Pump combination DI5 Pump capacity selection input 14 mm2 (VCT cable) 5
flow selection signal 20 Z+
DI4 Encoder
44 6 Z-
DI3 7
21 +5V
DI2 8
45 GND
DI1 Start/stop (Set in start status upon input of DC 24 V power)
* Motor start/stop 22 9 FG
DICOM
46
DGND
* Serial communication 23
RXD For servicing
47 1 GND
TXD
0.3 mm2 (AWG 22) 24 2 P_S Pressure
FG Pump
or greater 48 +5V sensor
FG 3 model

Ring core 1
(3 turns)
0.3 mm2 (AWG 22) or greater
(At the pressure sensor side)
Electric Wiring Diagram (Example with 400 V double pump type SUT00D13021)

SOL+
SOL Solenoid valve
SOL-
SUPER UNIT
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

Electric Wiring Diagram

36
37
Ring core (2 turns)
SUPER UNIT controller Noise filter
M3

25 L1
FG R L1
2 L2
GND S L2
26 L3
+5V T L3
3 E
Z- PE
27
Z+ Encoder
4 <Options> *1 <Options> *1
B-
28
0.3 mm2 (AWG22) or more B+
5
A-
29 Ring core (5 turns)
A+
6
THM+
30 Thermistor
THM- (No polarity) L1
7
AGND N 215 to 245 V
* Flow rate monitor 31 Flow rate monitor
QO E /50 to 60 Hz
8 M5
AGND
* Pressure monitor 32 Pressure monitor
PO
9 Regenerative resistance
AGND <Options> *1
Flow rate command Flow rate command (68 Ω × 2) 0.5 mm2 (CE cable)
33 1
QI
10 L1 0.5 mm2 (VCT cable)
AGND 2
Pressure command 34 Pressure command L2
PI 3
L3
4
11 P1 DC AC FAN
AGND DC reactor 5
P2 reactor
35 6 AC SUPER UNIT
P_S Pressure sensor 47 W
12 B1 FAN motor pump
+5V Regenerative resistance 7
36 B2
ALM_C 8
13 When power OFF, at alarms U U
Alarm monitoring ALM_B 9
37 ALM_B Motor power cable V V
ALM_A During normal operation 10
0.3 mm2 14 W W M
0V ALM_A
(AWG22) or greater 38 Ferrite core
DO7 Ring core (2 turns)
Ferrite core 15 <Options>*1
DO6 <Options>*1 THM
39
Machine side DO5
16 Th
controller DO4 Warning output
40 8 mm2 (VCT cable)
DO3 6 mm2 (CE cable)
17 1 A+
DO2
Operation possible 41 2 A-
without the items DO1 Ready to operate
18 3 B+
marked with* DI8
42 4 B-
DI7
19 5 Z+
DI6 Encoder
Pump combination flow 43 6 Z-
DI5 Pump capacity selection input
selection signal 20 7 +5V
DI4
44 8 GND
DI3
21 9 FG
DI2
45
DI1 Start/stop (Set in start status upon input of DC 24 V power)
* Motor start/stop 22
+24 V 1 AGND
46 P_S Pressure
DGND 2 Pump
* Serial communication 23 +5V sensor model
RXD For servicing 3
47
TXD
0.3 mm2 24
FG
(AWG22) or greater 48
FG

Flow rate selection block


0.3 mm2 (AWG22) or more
SOL+
Electric Wiring Diagram (Example with 400 V double pump type S-SUT00D8025)

Solenoid valve
SOL-
SOL
16 mm2 (70°C cable) * Linear filter with increased
38 mm2 (60°C cable) overload durability recommended

SUPER UNIT controller *2 *2


M3
Noise filter Noise filter
25
FG
2 R
GND L1' L1 L1' L1
26 S
+5V L2' L2 L2' L2
3 T
Z- L3' L3 L3' L3
27 PE
Z+ Encoder
4
B-
28
B+ *1 Ring core 2 (2 turns) 3-phase AC 380 to 440 V
5
A- (At the controller side) , 50 Hz/60 Hz
0.3 mm2 (AWG 22) or greater 29
A+ Max. 52.0 kVA
6
THM- Recommendation Breaker capacity 50 A
30 Motor thermistor
THM+ Regenerative resistance*2
24 (68 Ω × 6)
FG R
7
AGND N
* Flow rate monitor 31 Flow rate monitor
QO PE
8
AGND M8 1-phase AC 215 to 245 V
* Pressure monitor 32 Pressure monitor
PO , 50 Hz/60 Hz
9
AGND
Flow rate command 33 Flow rate command
QI 1 0.5 mm2 (70°C cable)
10 L1
AGND 2 0.5 mm2 (60°C cable)
Pressure command Pressure command Main power supply L2
34 3
PI
1 L3
FG 4 DC AC FAN
11 P1
AGND DC reactor 5
P reactor
35 AC SUPER UNIT motor pump
P_S Pressure sensor
12 Regenerative resistance FAN
+5V 6
36 C
ALM_C 7 U
13 U
Alarm signal ALM_B When power OFF, at alarms Motor 8 V
37 V
ALM_A ALM_B 9 W M
14 During normal operation W
DOCOM (0V)
38 ALM_A
DO7
15 THM
0.3 mm2 (AWG 22) DO6
39 *1 *1 Th
Machine side or greater DO5 Ferrite core Ferrite core
16
controller DO4 Warning output (At the controller side) (At the motor
40 side)
DO3
17
DO2 *1 1 A+
Operation possible 41
DO1 Ready to operate Ring core 2 (2 turns)
without the items 2 A-
18 (At the controller side)
marked with * DI8 3 B+
42
DI7 4 B-
19 10 mm2 (70°C cable)
DI6 14 mm2 (60°C cable) 5 Z+
Pump combination 43 Encoder
flow selection signal DI5 Pump capacity selection input 6 Z-
20
DI4 7 +5V
44
DI3 8 GND
21
DI2 9 FG
45
DI1 Start/stop (Set in start status upon input of DC 24 V power)
Start/stop 22
DICOM (DC+24 V)
46 AGND
DGND 1
* Serial communication 23 P_S Pressure
RXD For servicing 2 Pump
47 +5V sensor model
TXD 3
48
FG
SOL

0.3 mm2 (AWG 22) or greater


Flow rate selection block
Ring core 1 SOL+
(5 turns) Solenoid valve
Electric Wiring Diagram (Example with 400 V double pump type S-SUT00D20025)

(At the pressure sensor side) SOL-


SUPER UNIT
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

Electric Wiring Diagram

38
39
35 mm2 or greater
*7 SUPER UNIT controller
Ferrite core M8
Controller at the 3 turns
machine side (At the controller side) PQ control board PE
X1 R 3-phase AC 380 V
1 R
+24V Main power S , 50 Hz/60 Hz
+24 V power supply 2 Control power S
GND supply T
T Rated capacity 83 kVA
(DC+24 V 0.2 A) Shorting bar PE Recommended breaker capacity 200 A
*3 P1
X2
Regenerative P+
brake unit N-
Not used 35 mm2 or greater Regenerative resistor unit (4.5 kW, 8 Ω)
0.3 mm2
(AWG22) TH1
X3 R1
1 *5
PI Analog command input TH2
Pressure command 2 QI PI: Pressure command R2 1-phase 230 V
Flow rate command 3 Regenerative brake unit (85 A)
GND QI: Flow rate command E
4 50 Hz 0.6 A
*4 FG TH+ DB 60 Hz 0.68 A
5 Motor thermistor
TH- *6 P+ M6
P+ 0.5 mm2 or greater
X4
1 N-
DOCOM (DC+24 V/0 V) PE
Alarm signal 2 DO1 Alarm output
3 DO2 (Flow rate selection signal output)
4 TA
DO3 (Reserved output) AC
TB
FAN SUPER UNIT
TC
X5 motor pump
1 DICOM (DC+24 V/0 V)
Start/stop 2 35 mm2 or greater
DI1 Start/stop
*1 0V/DC+24 V 3 DI2 Regenerative brake alarm M8
4 DI3 Regenerative resistor alarm M8
5 U U
DI4
6 Motor V V M
DI5
7 (16-step PQ selection input) W W
DI6
8 DI7
Ring core 2
CN3 2 turns
(At the controller side)
Terminal block for servicing *7 Th
(right side of the operation panel display)

CN1 1 A+
AGND 2 A-
P_S Pressure sensor 3 B+
+5V 0.3 mm2 4 B- Encoder
FG (AWG20) 5 +5V
6 GND
CN2 7 FG
GND 8 Blank
+5V
B-
B+ Encoder AGND
0.3 mm2 1
A- P_S Pressure
(AWG22) 2 Pump
A+ Ring core 1 +5 V sensor
3 model
FG 5 turns
(At the pressure
sensor side)

0.3 mm2 (AWG22)


Electric Wiring Diagram (Example with 400 V double pump type S-SUT00S30018)
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

Memo

Electric Wiring Diagram

40
8-PQ Control

Control Method Selection


Procedure for Analog Command
Input Type SUPER UNITs (*2)

Setting the parameter (P31: CM_S)


Initial setting “0”: Selection of analog
Analog command command input type left unchanged
input selected? (controlled with command voltages Pi and Qi)
YES
2: Digital command input type (8-PQ)

NO

Selecting digital command


input type Flow rate selection type? Double pump, analog command input type
YES

Setting the parameter (P31: CM_S)


NO Selecting “combination”/“independent” flow, selected
“0” ⇒ “2”: Changing to digital
command input type (8-PQ control) based on conditions at the machine side

* See the parameter number on page Single pump, analog


42. command input type
Setting the parameter (H47: DI_L)
Making the change effective Combination flow with initial setting of “1” and DI5 =
by resetting the power to the Controlling with analog ON (reverse logic also possible)
controller command inputs (command
voltages Pi and Qi) from the
machine side
Selecting a PQ number from 8 patterns
through ON/OFF combination of digital Selecting “combination” flow by turning on the
input signals DI-3, DI-4 and, DI-6 from solenoid valve for selecting the flow rate of the SUT
the machine tool. See the table at the pump at the machine side and turning digital input
bottom of page 45. signal DI5 ON at the same time
⇒ SUT controller recognizes selection of
“combination” flow. ⇔ Controlling according to
command voltages Pi and Qi in the PQ area for
PQ0 to PQ7: Corresponding to
“combination” flow of the SUT controller
parameters P41 to P48
(When DI5 = OFF, the SUT controller recognizes
Executing PQ control for
“independent” flow and executes control according
high-pressure/independent pump based
to command voltages Pi and Qi in the PQ area for
on PH*, QH*, PL*, QL* and PC* settings
“independent” flow.)
(Single pump type: PL* and QL* only)
See the table on page 42.

Flow rate selection method:


Flow rate selection method:
Autonomous selection
“autonomous” or “external input
method
signal”? “Autonomous High-pressure/high-flow-rate/high-accuracy type
selection” method
SUPER UNITs control the pressure and flow rate
“External input Setting the parameter (H54: P_ C_) by changing analog input voltages.
signal” method (H54: Autonomous pump selection enable)
Changing from “0” to “1” (autonomous The 8-PQ control type, where digital ON/OFF
Selecting the flow rate selection enabled) signals (DC 24 V) are used for control, is also
method: External input signal method available.
(DI5)
Controlling by selecting the relevant parameter
When analog input voltages cannot be provided at
settings among PH, QH*/PL*, QL* for the machine side, the control method can be
“independent” ⇔ “combination” upon
Setting the parameter (H54: P_ C_) satisfaction of autonomous selection conditions changed from the analog command input type to
Keep initial value at “0”
(Flow rate selection by DI-5)
Turning digital output DO3 ON at the same time the 8-PQ control type, where combinations of 3-bit
digital ON/OFF signals (DC 24 V) are input from a
PLC (*1) at the machine side, using a parameter.
Setting autonomous selection conditions
Setting the parameter (H47: DI_L) (with parameters) With the 8-PQ control type, pressure/flow rate
Combination flow with initial setting of P36 to P38, H52, H53, H55, H47
“1” and DI5 = ON settings are preset as numerical values using 8
(reverse logic also possible) parameters and the pressure and flow rate are
Outputting DO3 = ON upon satisfaction of
specified by turning on the digital signal
Selecting “combination” flow by turning autonomous selection conditions corresponding to the parameter number that holds
on the solenoid valve for selecting the Actuating the solenoid valve (DC 24 V) for
flow rate of the SUT pump at the selecting “combination” flow of the SUT at the desired pressure/flow rate setting. (The 16-PQ
machine side the machine side in response to this DO3 control type is also available with some models.)
Input signal into DI5 at the same time output to run the SUT with “combination” (*1) PLC: Programmable Logic Controller
⇒ SUT controller recognizes selection flow selected
(*2) For details on selection of the control method, please
of “combination” flow. (Single pump type: No flow rate selection)
refer to the instruction manual provided separately.

41
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

The following table shows the settings and details of parameters given in “Control Method
Selection Procedure for Analog Command Input Type SUPER UNITs (SUT/S-SUT)”. (For details,
please refer to the instruction manuals for the analog command input type and for the 8-PQ control
type.)

Parameter No. Code Name Initial value Description

Pressure/flow rate command input target selection


0: Analog input
P31 CM_S Command input target selection 0
1: Cannot be set (reserved by system)
2: Digital input (8-pattern PQ type (8-PQ))

P41 − PQ selection 0 (PQ_0) - Double pump type (*1)


PH*: High-pressure (independent) side pressure setting
QH*: High-pressure (independent) side flow rate setting
P42 − PQ selection 1 (PQ_1)
rate for each of eight PQ patterns

PL*: Low-pressure (combination) side pressure setting


For setting the pressure/flow

QL*: Low-pressure (combination) side flow rate setting


P43 − PQ selection 2 (PQ_2) PC*: Pump selection condition
(enabled when using the autonomous selection function)
P44 − PQ selection 3 (PQ_3)
- Single pump type
P45 − PQ selection 4 (PQ_4) PL*: Low-pressure (combination) side pressure setting
QL*: Low-pressure (combination) side flow rate setting

P46 − PQ selection 5 (PQ_5)

P47 − PQ selection 6 (PQ_6)

P48 − PQ selection 7 (PQ_7)

Combination/independent selection logic for digital input signal DI5


For digital

Pump combination flow ON/OFF setting


input

H47 DI_L signal selection 1


0: Combination when DI5 = OFF, independent when DI5 = ON
1: Combination when DI5 = ON, independent when DI5 = OFF

Pump autonomous Double pump autonomous selection enable/disable setting


H54 P_C_ selection enable 0 0: Disabled (pump selection according to digital input DI5)
1: Enabled (autonomous selection according to selection conditions)

Pressure condition setting for autonomous combination ⇒


Independent flow independent pump selection
P36 CS_P 1.0
selection pressure offset Selecting independent flow under the following condition:
“PL*” + “CS_P” < Control pressure

Flow rate condition setting for autonomous combination ⇒


Independent flow independent pump selection
P37 CS_N 100 Selecting independent flow under the following condition:
selection flow rate offset
For autonomous selection setting (condition)

Control flow rate < “QH*” - Flow rate conversion of “CS_N”

Pressure condition setting for autonomous independent ⇒


Combination flow combination pump selection
P38 CD_P 1.0 Selecting combination flow under the following condition:
selection pressure offset
Control pressure < “PL*” - “CD_P”

Setting the time to maintain independent flow by disabling


H52 CS_T Independent flow hold time 0.3 independent ⇒ combination pump selection, immediately after
combination ⇒ independent pump selection

Setting the time to maintain combination flow by disabling


8-PQ Control

H53 CD_T Combination flow hold time 0.3 combination ⇒ independent pump selection, immediately after
independent ⇒ combination pump selection

Pump combination flow Time to maintain combination flow after starting the pumps from the
H55 SD_T 0.1 stopped state or standby state
hold time at startup

Pump capacity selection output logic in the autonomous selection


Pump combination flow method (switching the solenoid valve for selecting the flow rate at the
H47 DI_L 1 machine side according to digital output DO3)
signal selection
0: Combination when DO3 = OFF, independent when DO3 = ON
1: Combination when DO3 = ON, independent when DO3 = OFF

Note 1: “*” in PH*, QH*, PL* and QL* in the above table represents a PQ number from “0” to “7”.

42
Example Control
* The following shows example waveforms while controlling the pressure and flow rate on press machine a
SUPER UNIT incorporated.

Example with S-SUT00D20025-12YL (Pmax = 25 MPa (independent), Qmax = 200 L/min (combination), 400 V specifications)

Voltage × 0.01 [V] Upper die automatic 1 cycle


06: Rotating speed command (Voltage)
1,000
Down 1 Down 2 05: Pressure command (Voltage)
Pressurization Raised
08: Actual rotating speed (Voltage)
07: Actual pressure (Voltage)
800 Pi
Qi

600 Qi
Qo
Pi Po
Pi
Qo
400
Po
Po
200 Qi Qo

20
0 20,000 40,000 60,000 80,000 100,000 120,000

-200
time [ms] Pressure = 25 MPa/10 V (Independent)
Flow rate = 200 L/min/10 V (Combination)

Example with SUT00D15021-10-B (Pmax = 20.7 MPa (independent), Qmax = 150 L/min (combination), 200 V specifications)

05: Pressure command (Voltage)


Voltage × 0.01 [V] Press operation 07: Actual pressure (Voltage)
1,200 06: Rotating speed command (Voltage)
Down (high speed) Up (high speed) 08: Actual rotating speed (Voltage)
Qi
1,000
Down (low speed) Pressurization
Pi
800
Up (low speed)
600
Pi Qi
Po
400 Po

200 Qo
Qo

0 2,000 4,000 6,000 8,000 10,000 12,000 14,000


-200
time [ms] Pressure = 20.7 MPa/10 V (Independent)
Flow rate = 150 L/min/10 V (Combination)

43
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

Example Timing Chart for Cylinder Operation and Signals on a Press

Example Press Operation (Down-Press-Up) in 8-PQ Control (SUT00D15021, 200V Specifications)

The following shows an operation example using five setting patterns by setting the pressure and flow rate for
each process for PQ numbers 0 to 4, corresponding to PQ setting charts 1 to 5 .
(In this example, the selection of combination/independent flow is controlled from the machine using an
external signal (DI5).)
1 PQ setting
Selecting combination flow [L/min]
200
180
QL1
160
Cylinder position mm

140
Selecting independent flow 120
100
80
Selecting
60
independent
flow 40 QH2
20 PL1 PH2
0 [MPa]
Time (sec) 0 5 10 15 20 25

Selecting combination flow 2 PQ setting


1 [L/min]
200
4 180
160
Control flow rate L/min

140 QL2
120
2 5 2 5 100
5
80
60 QH2
40
Time (sec) 20 PL2 PH2
0
0 5 10 15 20 25
3
3 PQ setting
Control pressure MPa

[L/min]
200
180
160
140 QL3
120
Time (sec) 100
80
60 QH3
40
20 PL3 PH3
Standby 0
Press 1 Standby
0 5 10 15 20 25
Down (high speed) Up (low speed)
Press 2 4 PQ setting
[L/min]
Down (low speed) Up (high speed) 200
Pressure release 180
160 QL4
140
120
[L/min]
200 100
Maximum control range for combination flow 80
60
40 QH4
150 Maximum control 20 PL4 PH4
QL* range for independent 0 [MPa]
Example Control: Timing Chart of a Press

flow 0 5 10 15 20 25
100
5 PQ setting
[L/min]
200
QH* 50 180
160
140
0 [MPa] 120
0 5 10 15 20 25 100
80
PH* PL*
60
8-PQ Setting Example with SUT00D15021-10-B-N0365 40 QL0
20
Up to eight patterns of the flow rate for combination flow (QL*), pressure for QH0
[MPa]
0
combination flow (PL*), flow rate for independent flow (QH*) and pressure for 0 5 10 15 20 25
independent flow (PH*) can be set using parameters. The PQ settings shown in
the charts to the right are the example setting patterns applied to each of the indicates an example operating point when
operating ranges in the figures above. combination flow is selected.
indicates an example operating point when
independent flow is selected.

44
Example Timing Chart for Cylinder Operation and Signals on a Press

Example of 8-PQ Function: Example Timing Chart with SUT00S/S-SUT00S (Single Pump, 8-PQ Type)

Example Timing in 8-PQ Control (Single Pump)

Down Down Down


Flow rate (Q) (speed)

Pressure release Up (low speed)


(low speed) (high speed) (low speed) Up (low speed)

Press 1 Press 2 Stop Up (high speed) Stop

Q3
Flow rate
setting Q6 Speed Q5
Q1 Q2 Q7 Q4

Q0 Q0 Q0
Pressure (P) (thrust)

P1 P3 P6 P7 P5 P4

P2

Pressure setting

P0
P0 P0 Time
Load pressure Contacting the workpiece
Preparing for
operation 1 Cycle

Down solenoid valve


Up solenoid valve
Pressure release solenoid valve

S-SUT operation DI-1

DI-3
Pressure/speed setting
DI-4
Pattern selection signal
DI-6

Pattern No. Parameter No.


– P31 (To select the 8-PQ type, the setting of “P31” needs to be changed from “0: Analog input” to “2: Digital input”.)
PQ0 P41
PQ1 P42
PQ2 P43
PQ3 P44
PQ4 P45
PQ5 P46
PQ6 P47
PQ7 P48

Digital Selection Signals and PQ Numbers PQ Numbers and Example Pressure/Flow Rate Settings
DI-3 DI-4 DI-6 Pattern No. PL* [MPa] QL* [L/min]
off off off PQ0 PQ0 0.5 0.0
on off off PQ1 PQ1 16.0 10.0
off on off PQ2 PQ2 12.0 8.0
on on off PQ3 PQ3 16.0 70.0
off off on PQ4 PQ4 16.0 6.0
on off on PQ5 PQ5 16.0 80.0
off on on PQ6 PQ6 17.6 50.0
on on on PQ7 PQ7 16.0 10.0

Note: The analog command input type is selected by the default parameter settings of SUT/S-SUT before shipment. (Parameter P31 (command input target selection) is
set to “0: Analog input”.)
The setting of parameter P31 needs to be changed to “2: Digital input (8-PQ)”. (The setting change takes effect upon restarting the power.)
To achieve shockless control on a machine, the flow rate, pressure, response time and other settings need to be adjusted according to the machine.
45
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

Example of 8-PQ Function: Example Timing Chart with SUT00D13021


(Double Pump, 8-PQ Type, Flow Rate Selection by External Signal)

Example Timing with 8-PQ, Double Pump, External Signal (DI5) Selection Specifications
Flow rate (Q) (speed)

Down Down Down Pressure release Up (low speed)


(low speed) (high speed) (low speed) Up (low speed)

Up
Press 1 Press 2 Stop (high speed) Stop

Q3
Flow rate setting Q6 Speed Q5
Q1 Q2 Q7 Q4

Q0 Q0 Q0

P6 P7 P5 P4
Pressure (P) (thrust)

P1 P3 P2

Pressure setting
P0
P0 P0 Time
Load pressure Contacting the workpiece

Preparing for operation 1 Cycle

Down solenoid valve


Up solenoid valve
Pressure release solenoid valve

S-SUT operation DI-1

DI-3
Pressure/speed setting
DI-4
Pattern selection signal
DI-6
Selecting combination flow DI-5

SUT combination flow selection solenoid valve

Pump flow rate selection status Combination (low pressure) Independent (high pressure) Combination (low pressure) Independent

Pattern No. Parameter No.


– P31 (To select the 8-PQ type, the setting of “P31” needs to be changed from “0: Analog input” to “2: Digital input”.)
– P47 (The above charts show the status with “H47: Pump combination flow signal selection” set to “1: Combination when DI5 = ON” (default setting).)
(“H54: Autonomous pump selection enable” is set to “0: Disabled (pump selection according to digital input DI5)” (default setting).)
– P54
PQ0 P41
PQ1 P42
PQ2 P43
PQ3 P44
PQ4 P45
PQ5 P46
PQ6 P47
PQ7 P48
Timing Chart of a Press

Digital Selection Signals and PQ Numbers PQ Numbers and Example Pressure/Flow Rate Settings
DI-3 DI-4 DI-6 Pattern No. PH* [MPa] QH* [L/min] PL* [MPa] QL* [L/min] PC*
off off off PQ0 PQ0 1.0 5.0 1.0 10.0 1
on off off PQ1 PQ1 20.6 30.0 12.0 50.0 1
off on off PQ2 PQ2 20.6 30.0 18.0 30.0 1
on on off PQ3 PQ3 20.7 30.0 12.0 130.0 1
off off on PQ4 PQ4 20.6 30.0 14.0 30.0 1
on off on PQ5 PQ5 20.6 30.0 18.0 130.0 1
off on on PQ6 PQ6 17.0 40.0 17.6 40.0 1
on on on PQ7 PQ7 20.6 30.0 18.0 50.0 1

Note: This example shows operation of SUT00D13021 (200 V specifications) with 8-PQ type and flow rate selection by external signal (DI5) selected.
Flow rate selection by the 8-PQ function can also be used in the autonomous selection mode. For details on the 8-PQ control, please refer to the instruction
manual provided separately.
To achieve shockless control on a machine, the flow rate, pressure, response time and other settings need to be adjusted according to the machine.
46
Maintenance/Management Tool (Hybrid-Win)
Hybrid-Win is a software tool that connects your personal computer running Windows 7/8 to a SUPER UNIT through communications (RS232C) P C t o o l
to enable editing/saving of SUPER UNIT parameters and measurement of waveforms that result from the pressure/flow rate control.
Hybrid–win and its instruction manual are available from the website (http://www.daikinpmc.com) after registering as a member.
A personal computer and an RS232C/USB conversion cable are necessary.

Startup Window of Hybrid-Win


Hybrid-Win can also be used for maintenance of other hybrid products
from DAIKIN such as ECORICH products and oil cooling units.
The startup window has the [Parameter transfer], [Simple measurement],
[Trigger measurement], [Wave form measurement] and [Alarm history]
buttons as shown in the figure to the left to provide access to the major
functions of Hybrid-Win. Some basic functions are covered here.
(Please refer to the instruction manual provided separately for details.)
: [Parameter transfer]
: Waveform measurement:
[Simple measurement] : [Trigger measurement]
: Waveform measurement: : [Alarm history]
[Wave form measurement]

Loading Parameters from SUPER UNIT


(Parameter Transfer)
Clicking the “From Unit to PC” button transfers parameter data from the
Super Unit to the personal computer and displays the parameters on the
❶ Hybrid-Win window shown to the left.
The parameters can be edited and saved in this window.

❶ : [From Unit to PC] button

Measuring Waveforms of SUPER UNIT


Click the [Communication start] button and select four data types to be
displayed.
Clicking the [Measure start] button starts the measurement and the
waveforms are displayed on the software screen as shown in the figure
to the left over an extended period (90 seconds, when the sampling time
is set to 15 ms for example) until the [measure stop] button is clicked.
❷ The waveform data can also be saved in the Excel graph format.

❸ ❶ ❶ : [Communication start] button


❷ : Selecting data to be displayed
❸ : [Measure start] button

Zooming the Measured Waveforms In/Out


By checking “2Axis” for data types to be displayed, the chart can be zoomed
along each of the vertical axes as shown in the figure to the left. The figure to
the left shows the waveforms with the command pressure (voltage) and current
Waveforms for the rotating pressure (voltage) assigned to the left axis, the command rotating speed
speed command and
current rotating speed (voltage) and current rotating speed (voltage) assigned to the right axis, and
Pressure command and current pressure
both axes zoomed using the “Vertical” and “Vertical 2” [+] buttons. It is also
❶ ❷ ❸ possible to zoom the chart along the horizontal axis (time).
This function can be used for monitoring waveforms on the screen while the
SUPER UNIT is running and saving some significant waveforms as Excel data.
❶ : Selecting data type to be displayed as “2Axis”
❷ : “Vertical” zoom in/out buttons
❸ : “Vertical 2” zoom in/out buttons

47
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

Window Displayed by Clicking [Trigger measurement]


This window appears when the [Communication start] button is clicked after the
❷ [Trigger measurement] button in the start window to enable selection of the
❶ ❹ sampling time, four data types to be measured and trigger conditions.
When the trigger conditions are satisfied after clicking the [Measurement start]
button, the measurement starts and the waveforms are displayed as an Excel graph
❸ upon completing the measurement. (When Excel is selected as the file saving
format) When the sampling time is set to 20 ms for example, measurement is
possible for 5.1 seconds. It is also possible to save the data in the CSV format.

❶ : [Communication start] button ❷ : Selecting “Measurement data”


❸ : “Trigger condition setting” ❹ : [Measurement start] button

Measurement Results when Excel File Selected as the Target


with [Simple measurement] or [Trigger measurement]
When Excel file is selected as the file saving format with the [Simple
measurement] or [Trigger measurement] function, Excel window as
shown in the figure to the left automatically appears upon completing
the measurement to show the measurement data in a graph.
The graph can be adjusted for better visibility by correcting/modifying
its time axis and vertical axes using Excel, and saved as Excel data.

Example of Measured Waveforms after being Edited in Excel


When Excel file is selected as the file saving format with the [Simple
measurement] or [Trigger measurement] function, the waveforms are
displayed in an Excel graph automatically upon completing the
measurement. The figure to the left shows an example after editing
the displayed waveforms for better visibility.

Alarm Window Displayed by Clicking


Maintenance/Management Tool Hybrid-Win

❶ [Alarm history]
The window displays details on the latest 10 alarms.
Information on the alarms including the alarm number and the total
❷ operating time at the occurrence of the alarm can be checked in the
table as shown in the figure to the left. The data can also be saved
as Excel data or in other formats.

❶ : [Excel output] button


❸ ❷ : Alarm number
❸ : Total operating time (after shipment)

48
External/Installation Dimension Diagrams for Electrical Components

DC Reactor
PM-SDL03 PM-SDL04
112 105
92 75

Height
95 mm

75
105

112
92
4-5.5 × 8
For M5
with ring terminal Length of lead wire
4 slots for M5 Length of lead wire: 140 mm 140 mm
PM-SDL03/PM-SDL04 Height: 91 mm V5.5-5

PM-SDL05 PM-SDL06
133 97
90 82

MAX 150
Height

100

80
64
MAX Height
180 mm 86 mm

4-5.3 × 8.0 4-4.5 ×


(Slot) 6.5 mm slot
Crimp terminal, M8
PM-SDL05

Noise Filter

IN OUT PM-SNF01 PM-SNF02


L1 S
L2 R 170 179
L3 T 155 5 167
PE 73
PM-SNF01 PM-SNF02 6-φ4.5
IN

OUT

L1 L4
L1 L2 L3 PE

80
90

L2 L5

70
90
S R T

L3 L6
M5 screw
M5 screws
66
Height: 54 mm M4 screw for 2-φ4.5
150 5 2-4.5 × 6 slot grounding
PM-SNF03 PM-SNF07 Height: 55 mm

PM-SNF03 PM-SNF04 PM-SNF07


M6
246 7 M6 (6x) 177
215 162 M5
5.3

L1 L1'
LOAD

FN3011-75-62
LINE
70

IN
L2 L2'
OUT
L1 L1'
100

1
L3 L3'
85

4
44
65
2 L2 L2'
5
3 6
L3 L3'
M4 screw 177
196
2-φ5.5 × 7 2-φ5.5 214 Height 4-φ5.3 × 6.5
M5 × 6 (slot)
84 mm
Height: 140 mm Height: 85 mm

Regenerative Resistance
PM-RB02
RBP2-4

PM-RB02: 30Ω 500W


5.3
58

Length of lead wire


500 mm PM-RB04: 10Ω 500W
320
PM-RB06: 68Ω 500W
335
Height: 30 mm

Ring Core
PM-SRC01 PM-SRC02
17 47
φ20.6
φ49

φ24

φ40

49
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type

SUPER UNIT

Ferrite Core
PM-FC01 PM-FC04 PM-FC05

41
47

φ10.5
26.6 34
φ31.7

φ20.6
φ14

φ40

25.4
PM-FC01

Pressure Sensor Harness/Encoder Harness

PM-SPH05/PM-SH10 Pressure sensor harness PM-SEH05-P22-A09R/PM-SEH05-P22-A12R


Encoder harness

Model code Cable length Remarks


PM-SPH05-001 With ferrite core 2T Model code Cable length Remarks
PM-SPH05-002 5m With ring core 3T PM-SEH05-P22-A09R 9-pin
5m
PM-SPH05-003 Ring core PM-SEH05-P22-A12R 12-pin
PM-SPH10 10 m Ring core PM-SEH10-P22-A09R 10 m 9-pin

Electrical Components Provided with S-SUT00S25018, S-SUT00S30018, S-SUT00D30025

Regenerative brake unit SB-PP03158-03 Regenerative resistance SB-PP03159-05 Ferrite core SB-PP02137-02

4-φ5.5 holes (for fixing bolts) 4-φ6 holes (for fixing bolts) 41
(M5 bolts recommended) (M5 bolts recommended)
341
125
291
φ20.6

80
φ14

Height: H = 171

Height: H = 140
Ring core SB-PP0404-02
248
260

618
638

TA TB TC

21
Terminal block,
M6 screw
DB P+ P+ N-
φ75.7

φ44.2

Th1 R1 Th2 R2 □E

Terminal block, M6 screw

Pressure sensor harness SB-PP03151-01 Encoder harness SB-PP03706-01


External/Installation Dimension
Diagrams for Electrical Components

Length: L = 5 m with ring core Length: L = 5 m

50
High Pressure High Flow Rate
Analog Command Input High Accuracy

SUPER UNIT
HYBRID HYDRAULIC UNIT

Osaka Office
YODOGAWA PLANT
1-1, Nishi-Hitotsuya, Settsu, Osaka 566-8585, Japan
Phone: 81-6-6349-4475
Fax.: 81-6-6349-7862
Home Page: http://www.daikinpmc.com/en/

All World Machinery Supply, Inc.


A member of Daikin group
6164 All World Way, Roscoe, IL 61073, U. S. A.
Phone: +1-815-943-9111
Fax.: +1-815-943-5370
Home Page: http://www.allworldmachinery.com/

Contents in this catalog are subject to change for improvement without prior notice.

GK250(2016.12.010)DF.MD.MD

You might also like