GK250
GK250
SUPER UNIT
Nomenclature P.3
Features P.4 to 5
About Continuous
and Short-time P.13
Rating Range
Pressure – Flow
Rate Characteristics P.18 to 20
(Double pump)
External Dimension
Diagrams P.21 to 24
(Single pump)
External Dimension
Diagrams P.25 to 28
(Double pump)
External Dimension
Diagrams P.29 to 31
(Controller)
Maintenance/
External/Installation
Dimension Diagrams for P.49 to 50
Maximum
discharge
rate SUPER UNIT (Analog Command Input, High-accuracy Type) Model List by Pressure/Flow Rate
250 S-SUT00S25018
L/min
380 V
50 SUT00S5021 S-SUT00S5025
L/min 200/400 V 200 V
30 SUT00S3018 SUT00D3021
L/min 200 V 200 V
Maximum (Note 5)
operating
pressure 18 MPa 21 MPa 25 MPa 28 MPa
Note 1 All models allow selection of the input type as the analog command input type or 8-PQ digital command input type using a parameter. (Factory default is the analog command input type.)
Note 2 All models are tankless units with a split type controller (electrical components).
Note 3 Flow rate/pressure combinations other than those given in the model list above are also available. Please consult us when considering adoption.
Note 4 When a discharge rate higher than 300 L/min is required, it can be achieved by combining multiple SUPER UNITs. Please consult us for detailed information.
Note 5 We plan to develop 28 MPa specifications sequentially from October 2016 to March 2017. Please consult us for detailed information.
Maximum
discharge
SUPER UNIT (High-functionality Type) Model List by Pressure/Flow Rate
rate
Maximum
operating
pressure
7 MPa 10 MPa 16 MPa 21 MPa
Note 1 All models are 16-PQ control type units. The communications type and analog command input type (single pump type only) can be selected as optional models.
Note 2 A motor pump type (tankless) and unit type (with tank) are available. Please refer to the separately provided SUPER UNIT catalog (GK244) for details.
01
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
Power Maximum
Nominal motor Maximum Maximum flow rate [L/min]
supply Flow rate operating PQ 8-PQ Figure
02
Nomenclature
● 18 : 17.6 MPa
● 21 : 20.6 MPa
● 25 : 25.0 MPa
f Design No.
● 10 : Design No.
Incremented at model changes
*1
200/400 V cited as power supply voltage specifications are nominal voltages.
Refer to the specification tables and separately provided model drawings for details on the operating range.
03
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
Main Features and Functions
High The analog command input/high-accuracy type SUPER UNITs have operating ranges
Voltage/High extended to include high pressure and high flow rate ranges, enabling PQ control with
Flow Rate even greater accuracy than conventional SUPER UNITs (high-functionality type).
Achieving stable servo control in response to analog input voltages over a range from
High low pressure (1%)/flow rate (1%) to the maximum pressure/flow rate.
Accuracy The double pump type units enable low-pressure/high-flow-rate control in the combination flow mode, and
high-pressure holding (continuous) control over a prolonged period in the individual flow mode.
Features
Energy Saving
Energy savings at least 60% greater than conventional fixed displacement pump systems
(The energy-saving effect varies depending on the operation conditions.)
Average power
● Significant reduction of running costs with a small investment. 40 consumption:
Power consumption (kW)
60 consumption:
50
13.9 kW
Oil cooler downsized by suppressing oil temperature rise 40
30
● Fewer oil changes by restricting hydraulic oil deterioration. 20
Further, downsizing the hydraulic oil tank and oil cooler reduces 10
load. 20
150
● Highly accurate control with respect to
Flow rate [L/min]
Pressure [MPa]
16
0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Pressure command PI [V] Flow rate command QI [V]
Low-pressure control: Low flow rate control:
Minimum control pressure = 1% F.S. or higher Minimum control flow rate = 1% F.S. or higher
04
Main Features and Functions
Features
05
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
Functions
Features/Functions
The software tool Hybrid-Win, which can manage default parameter settings, read the alarm history, and save parameter data,
allows easy maintenance and management of the SUPER UNIT simply by preparing a personal computer (Windows 7/8) and
a communications cable (RS232C/USB conversion cable).
Note: A personal computer with Windows 7/8 operating system and an RS232C/USB conversion cable are necessary.
Communications cables (3-core soldered cables PM-CM02-15 for 1.5 m and PM-CM02-30 for 3 m) are available as options (to be ordered separately).
Note: Hybrid-Win is a software tool to provide functions for editing or saving parameters and measuring waveforms of a SUPER UNIT, and runs on a personal computer
connected to the SUPER UNIT using a communications cable.
Hybrid–win and its instruction manual are available free of charge from the website (http://www.daikinpmc.com/) after registering as a member.
(*1) Please consult us for detailed information on predictive maintenance.
06
Circuit Configuration Examples (Double pump specifications)
CYL-2
Main cylinder
CYL-1 (upper die)
SOL5
P T P T P T P T
Machine’s
setting unit
Low-pressure
pump
High-pressure
pump
M
Rotary encoder
Motor pump
(*1) There are two types of flow rate selection circuit, the type built into the pump discharge block and the separately installed type.
(*2) A safety valve needs to be incorporated in hydraulic circuits at the pump discharge side for safety.
07
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
Maintenance software
(Hybrid-Win)
Combination/independent Encoder
pump selection solenoid valve, Suction port T1 T2
DC 24 V control voltage
Cooling fan
Fan power supply Machine side
1-phase AC 215 to 245 V 50/60 Hz
08
06
Specifications by Product (Single pump 200 V/400 V specifications)
200 V specifications 400 V specifications
SUT00S SUT00S S-SUT00S
13018-10YA-N0218
13021-11YA-N0286
20018-20YL-N0340
5021-20YA-N0265
5025-10-L-N0432
15018-10YA
25018-10YA
30018-10YA
15018-10-A
8018-21YA
3018-30-A
5021-30-A
8018-30-A
Model
Item
Maximum operating pressure [MPa] 17.6 20.6 17.6 24.5 17.6 20.6 17.6 17.6 20.6 17.6 17.6
Maximum flow rate [L/min] 30 50 80 50 150 50 80 130 150 200 250 300
Operating pressure 0.18 0.21 0.18 0.25 0.18 0.21 0.21
[MPa] 0.18 to 17.6 0.18 to 17.6 0.18 to 17.6
adjustment range to 17.6 to 20.6 to 17.6 to 24.5 to 17.6 to 20.6 to 20.6
Operating flow rate
adjustment range [L/min] 0.3 to 30 0.5 to 50 0.8 to 80 0.5 to 50 1.5 to 150 0.5 to 50 0.8 to 80 1.3 to 130 1.5 to 150 2.0 to 200 7.5 to 250 9.0 to 300
Pump Pump type Single geared pump Single geared pump Single geared pump
model
Pump capacity [cm3] 9.13 20.7 31.2 27.4 52.7 20.7 31.2 44 52.7 73 − −
3-phase AC 380 V
Controller input power (*1) 3-phase AC 200 to 220 V (50 Hz/60 Hz) 3-phase AC 380 to 440 V(50 Hz/60 Hz) (50 Hz/60 Hz)
Permissible power supply
voltage fluctuation range –15% to +10% –20% to +10% −15% to +15%
[min ] −1
2,340 1,800 1,800 −
Rated value
[N⋅m] 28 58.4 58.4 − 117 −
Controller rated input current [A] (*3) 25.3 35.6 20 23.3 19 − 40 88.0 114.0
Motor rated input current [A] (*3) 29.2 38.3 27.5 27.7 21 − 45 73.2 88.9
Leak current [mA] (*3) − − 3 3.2 2.1 − 2.8 8.9
Motor pump [kg] 40 69 70 92 103 69 70 103 104 103 118 246 342
Controller [kg] 11 11 − 14 52 63
Mass Regenerative [kg]
resistance unit − 12
Regenerative
[kg] − 3
brake unit
Analog command input voltage DC [V] (*4) 0 to +5 0 to +10 0 to +10
Non-standard Suction flange/block Incorporated None Incorporated None Incorporated None Incorporated None Incorporated Incorporated
specifications Safety valve (*5) Incorporated None Incorporated Incorporated None Incorporated
(*1) Even if the unit is used within the permissible power voltage fluctuation range, the PQ output characteristics may deteriorate if the power voltage fluctuates to the negative side.
Also note that power voltage fluctuation to the positive side may cause alarms, due to overloading of regenerative operation, depending on the operation conditions. You are
therefore recommended to use the unit in an environment with limited power voltage fluctuation as far as possible.
(*2) With the S-SUT00S25018 and S-SUT00S30018 specifications, the DC 24 V control power (0.2 A minimum) needs to be input at the same time as the controller’s AC power
supply voltage.
(*3) Representative values when using a noise filter recommended by DAIKIN. Protection against noise, in accordance with DAIKIN’s recommendations, may be required
depending on the operating environment.
(*4) With 5 V analog command input voltage specifications, the voltage can be adjusted from 0 to 5 V using parameter VMAX. With 10 V specifications, the voltage can be adjusted
from 0 to 10 V, so it can also be operated with 5 V inputs.
(*5) With models without a safety valve in the discharge block, incorporate a safety valve in the hydraulic circuit at the machine side. Use the unit with the safety valve set at the
maximum operating pressure + 2 MPa.
09
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
13021-10YB-N0322
15021-10YB-N0358
13021-10-B-N0321
15021-10-B-N0365
8021-21YB-N0324
3021-30-B-N0436
8021-30-B-N0323
30025-10YA
20021-12YL
13025-11YL
20025-20YL
20021-10-L
8025-11YL
Model
Item
Maximum Combination [MPa] 17.6 20.6 17.6 11.0 17.6 20.6 17.6 11.0 15.0 17.0 17.5
operating pressure Independent [MPa] 20.6 25.0 20.6 25.0
Combination [L/min] 30 80 130 150 200 80 130 150 200 80 130 200 300
Maximum flow rate
Independent [L/min] 18.3 38.4 47.9 70.9 56.0 38.4 47.9 70.9 56.0 40.0 37.0 56.0 160.0
Operating pressure
adjustment range [MPa] 0.21 to 20.6 0.25 to 25 0.21 to 20.6 0.25 to 25
Specifications
Operating flow rate
adjustment range [L/min] 0.3 to 30 0.8 to 80 1.3 to 130 1.5 to 150 2.0 to 200 0.8 to 80 1.3 to 130 1.5 to 150 2.0 to 200 0.8 to 80 1.3 to 130 2.0 to 200 9.0 to 300
Required power
Power supply capacity [kVA] 11.3 23.2 33.8 20.1 34.8 34.8 20.1 34.8 52 84.0
supply
1-phase
Motor cooling fan power 1-phase AC 200 V ±10% (50 Hz/60 Hz) 1-phase AC 215 to 245 V (50 Hz/60 Hz) AC 230 V ±15%
(50 Hz/60 Hz)
DC 24 V ±10%
Controller control power (*2) − − 0.2 A
Flow rate selection DC 24 V − −
(*3) DC 24 V ±10% (*5) DC 24 V ±10% (*5) − (*6) (*6)
solenoid valve power (*4) (*6)
(*1) Even if the unit is used within the permissible power voltage fluctuation range, the PQ output characteristics may deteriorate if the power voltage fluctuates to the negative side.
Also note that power voltage fluctuation to the positive side may cause alarms, due to overloading of regenerative operation, depending on the operation conditions. You are
therefore recommended to use the unit in an environment with limited power voltage fluctuation as far as possible.
(*2) With the S-SUT00S25018 and S-SUT00S30018 specifications, the DC 24 V control power (0.2 A minimum) needs to be input at the same time as the controller’s AC power
supply voltage.
(*3) Please refer to “List of Electrical Components” for the electrical components required.
(*4) Solenoid valve model: KSOB-G02-9AP-40-N-H7 (minute signal current type solenoid valve, power supply voltage: DC 24 V ± 10%)
(*5) Solenoid valve model: KSO-G03-20BP-20-EN (power supply voltage: DC 24 V ± 10%)
(*6) Not equipped with a solenoid valve for flow rate selection (Arrange a separately installed type flow rate selection block or provide a flow rate selection mechanism in the
hydraulic circuit at the machine side.)
(*7) Representative values when using a noise filter recommended by DAIKIN. Protection against noise, in accordance with DAIKIN’s recommendations, may be required
depending on the operating environment.
(*8) With 5 V analog command input voltage specifications, the voltage can be adjusted from 0 to 5 V using parameter VMAX. With 10 V specifications, the voltage can be adjusted
from 0 to 10 V, so it can also be operated with 5 V inputs.
(*9) With models without a safety valve in the discharge block, incorporate a safety valve in the hydraulic circuit at the machine side. Use the unit with the safety valve set at the
maximum operating pressure + 2 MPa.
10
Common Specifications
Specifications by Product (Single pump
(30 L/min to 200200
L/min,V/400 V specifications)
single/double pump, 200 V/400 V specifications)
Item Specifications
Command resolution: 0.1 [%]
Analog command input (*1) 5 V specifications: 0 to +5 V / 0 to PMAX
Pressure command Pi
10 V specifications: 0 to +10 V / 0 to PMAX
(2ch)
Flow rate command Qi 5 V specifications: 0 to +5 V / 0 to PMAX
10 V specifications: 0 to +10 V / 0 to PMAX
Pressure monitor Po 5 V specifications: 0 to +5 V / 0 to PMAX
Analog output (*1) 10 V specifications: 0 to +10 V / 0 to PMAX
(2 ch) 5 V specifications: -5 to +5 V / -QMAX to +QMAX
Flow rate monitor Qo
10 V specifications: -10 to +10 V / -QMAX to +QMAX
Photo-coupler insulation, DC +24 V (27 V maximum), 5 mA/channel
Shared positive/negative common
DI1 Start/stop signal (control stop signal)
Digital input signal (*2)
(8 ch) DI3, DI4, DI6 PQ number selection signal for 8-PQ type (3-bit)
DI5 Pump capacity selection input (for flow rate selection specifications)
DI2, 7, 8 (Unassigned)
Photo coupler insulation, open collector, DC +24 V, 30 mA maximum
Negative common
DO1 Ready to operate signal
Digital output signal (*3)
(7 ch) DO3 Pump capacity selection output (for autonomous flow rate selection specifications)
DO4 Overload warning output (OFF: normal, ON: Warning)
DO5 to 7 (Unassigned)
Contact output (alarm) (1 ch) Dry contact: DC 30 V, 1 channel, 500 mA maximum
Motor pump No paint, only fan cover is in black
Paint color
Controller Ivory white (Munsell code 5Y7.5/1)
Oil type Mineral-oil base hydraulic oil, wear resistance hydraulic oil
Oil temperature 0 to 60 [°C] (Recommended operating temperature range: 15 to 50 [°C])
Oil used (*4) Viscosity grade ISO VG32 to 68
Viscosity range 15 to 400 mm2/s
Contamination Within NAS class 9
Indoors (not exposed to direct sunlight)
Atmosphere Not to be subject to corrosive gases, inflammable gases, oil mist or dust
Altitude 1,000 m maximum
Ambient humidity 85% RH maximum (no dew condensation)
Operating Ambient Motor pump 0 to 40°C (no freezing)
environment temperature Controller 0 to 55°C (no freezing)
Installation Motor pump To be secured on the base for the hydraulic unit on the machine. To be installed horizontally
orientation Controller To be installed inside an electrical cabinet (IP54). To be installed in the vertical orientation (with the main power supply terminals at the bottom)
Controller IP00
Protection grade
Motor (*5) IP44
(*1) There are two different voltage specifications: 5 V specifications and 10 V specifications. The PMAX and QMAX settings can be selected
using parameters. The input and output voltage settings can be selected using parameter VMAX.
(*2) When incorporating a semiconductor relay in the circuit, select a product with a leak current specification of 1 mA maximum.
(*3) When incorporating a relay in the circuit as a load, take necessary measures against surge or select a surge-resistant product.
(*4) Consult DAIKIN about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.
(*5) The shaft through hole, encoder connector, motor cooling fan and terminal block are excluded.
11
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
Common Specifications (250 L/min to 300 L/min, single/double pump, 400V specifications)
Item Specifications
Command resolution: 0.1 [%]
Analog command input (*1)
Pressure command Pi 0 to +10 V/0 to PMAX
(2 ch)
Flow rate command Qi 0 to +10 V/0 to QMAX
(An output harness is used only for the models with the non-standard code “-001” or “-003”.)
Analog output (*1) Pressure monitor Po 0 to +9.99 V/0 to PMAX
(2 ch)
Flow rate monitor Qo 0 to +9.99 V/0 to QMAX
Photo-coupler insulation, DC +24 V (27 V maximum), 5 mA/channel
Shared positive/negative common
DI1 Start/stop signal (control stop signal)
DI2 Regenerative brake unit alarm signal
Digital input signal (*2) DI3 Regenerative resistance unit alarm signal
(5 ch)
DI4, DI5, DI6, DI7 PQ number selection signal for 16-PQ type (4-bit, 18 MPa specifications)
DI7 Pump capacity selection input (flow rate selection, analog command input specifications)
DI4 to 7 (Not used, analog command input, single pump specifications)
Photo coupler insulation, open collector, DC +24 V, 30 mA maximum
Specifications
Shared positive/negative common
Digital output signal (*3)
DO1 Alarm signal
(3 ch)
DO2 Pump capacity selection output (flow rate selection, analog command input specifications)
DO2, 3 (Not used, analog command input, single pump specifications)
Oil type Mineral-oil base hydraulic oil, wear resistance hydraulic oil
Oil temperature 0 to 60[°C] (Recommended operating temperature range: 15 to 50[°C])
Fluid used (*4) Viscosity grade ISO VG32 to 68
Viscosity range 15 to 400 mm2/s
Contamination Within NAS class 9
Indoors (not exposed to direct sunlight)
Atmosphere Not to be subject to corrosive gases, inflammable gases, oil mist or dust
Altitude 1,000 m maximum
Ambient humidity 85% RH maximum (no dew condensation)
Operating
environment Ambient Motor pump 0 to 40°C (no freezing)
temperature Controller 0 to 40°C (no freezing)
Installation Motor pump To be secured on the base for the hydraulic unit on the machine. To be installed horizontally
orientation Controller
To be installed inside an electrical cabinet (IP54). To be installed in the vertical orientation (with the main power supply terminals at the bottom)
Controller IP20
Protection grade
Motor (*5) IP54
(*1) There are two different voltage specifications: 5 V specifications and 10 V (*3) When incorporating a relay in the circuit as a load, take necessary measures against
specifications. The PMAX and QMAX settings can be selected using parameters. surge or select a surge-resistant product.
The input and output voltage settings can be selected using parameter VMAX.
(*4) Consult DAIKIN about the use of hydraulic oils other than mineral-oil base type (e.g.
(*2) When incorporating a semiconductor relay in the circuit, select a product with a leak hydrous/synthetic) such as water-glycol hydraulic oil.
current specification of 1 mA maximum.
(*5) The shaft through hole, encoder connector, motor cooling fan and terminal block are
excluded.
Performance Specification
200 V specifications 400 V specifications
Model SUT00S / SUT00D SUT00S / SUT00D S-SUT00D S-SUT00S S-SUT00D
S3018, S5021, S5025, S8018, S13018, S15018 S5021, S8018, S13018, S13021, S15018, S20018 – S25018, S30018 –
Item
D3021, D8021, D15021, D20021 D8021,D13021, D15021 D20021 – D8025, D13025, D20025
Linearity F.S. 1[%] F.S. 1[%]
characteristics
Flow rate
Note: The data given above are the representative performance values, not guaranteed values.
(*1) Time required to reach 95% of the commanded value in response to a command to change the flow rate from 0 to the maximum with no load applied. With S-SUT00S25018 and
S-SUT00S30018, it is the time required to reach 90% from 10% under the same condition.
(*2) Time required to reach 95% of the commanded value in response to a command to change the pressure from 0 to the maximum. The volumetric load capacity condition is 2 m of 3/4
high-pressure hose with SUT00S3018 to SUT00S13021, and 2 m of 1B high-pressure hose with SUT00S20018.
With S-SUT00S25018 and SUT00S30018, it is the time required to reach 90% from 10% under the same condition. The volumetric load capacity condition is 2 m of 1-1/2B high-pressure
hose and a 10 L cylinder with S-SUT00S25018, and 2 m of 1-1/4B high-pressure hose × 2 and a 10 L cylinder with S-SUT00S30018.
12
About Continuous and Short-time Rating Range
Analog command input/high-accuracy type SUPER UNITs can run continuously within the continuous
rating range given in the pressure - flow rate characteristic charts (see P-Q charts on pages 15 to 20).
Note, however, that the range of operation can be extended to within the short-time rating range for
up to 20 seconds (or 60 seconds for the 400 V single pump type), provided it does not exceed a 20%
duty cycle.
Example with Single Pump Type Example with Double Pump Type
SUT00S20018-20YL-N0340 SUT00D13021-10-B-N0321
Continuous Short-time
rating range rating range
250 200
200 150
Short-time rating
150
100 Independent flow -
Continuous rating
100
50
Combination flow -
50 Continuous rating
0
0 5 10 15 20 25
0
0 5 10 15 20 Pressure [MPa]
Pressure [MPa]
Continuous rating : Continuous operation is possible when the mean hydraulic power obtained based
on the pressure and flow rate during operation of 1 cycle is lower than the hydraulic
power for the continuous rating range in the figure above and also the
root-mean-square of the load pressure is within the maximum pressure for the
continuous rating range.
(With the double pump type unit shown in the figure above with independent flow
selected, continuous operation with the pressure held at 20.6 MPa is possible.
However, for cycles that include pressure holding for 3 minutes or longer, a bleed
off circuit equivalent to the capacity of a single pump running at 150 min-1 must be
provided at the pump discharge side to cool the pump.)
Short-time rating : Operation possible for 20 seconds (or 60 seconds with 400 V single pump type)
Reference
How to obtain the mean hydraulic power and
root-mean-square pressure (example for single pump type)
When load pressure in each process within 1 cycle is Pn (n = 1, 2, ...., n), flow rate is Qn (n = 1,
2, ...., n), and time is tn (n = 1, 2, ...., n)
Mean hydraulic power = (P1×Q1/60×t1+P2×Q2/60×t2+...+Pn×Qn/60×tn) / (t1+t2+…+tn)
Root-mean-square of load pressure = SQRT((P12×t1+P22×t2+...+Pn2×tn) / (t1+t2+...+tn))
(Note, however, that if the pump runs above the rated pump rotational speed of 1800 min-1 to provide the
control flow rate of Qn, with the load pressure Pn, Pn needs to be converted to the value when the pump is
running at 1800 min-1.)
When the pump capacity of the SUPER UNIT is qn [cm3], the pump rotational speed Nn is Nn = Qn×103/qn.
Therefore, converted pressure Pn = Pn×(Nn/1800)
Note 1: The procedure for obtaining the mean hydraulic power and root-mean-square pressure with flow-rate-selection
specifications (double pump type) is basically the same as above. Please consult us for detailed information.
Note 2: SQRT above represents square root operation ( ). For the continuous rating hydraulic powers for each model, see the
pressure - flow rate characteristic charts (P-Q characteristic charts) given in the instruction manual provided separately.
13
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
24 200
20
150
16
12 100
8
Linearity ≤ 1%F.S Linearity ≤ 1%F.S
50
Hysteresis ≤ 1%F.S Hysteresis ≤ 1%F.S
4
0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Pressure command PI [V] Flow rate command QI [V]
24 100
Independent Independent
20
Combination 80 Combination
Flow rate [L/min]
Pressure [MPa]
16
60
12
40
8
20
4
0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Pressure command voltage PI [V] Flow rate command voltage QI [V]
12 12
Independent Independent
10 10
Combination Combination
Output voltage Qo [V]
Output voltage Po [V]
8 8
6 6
4 4
2 2
0 0
0 2 4 6 8 10 12 0 2 4 6 8 10 12
Pressure command voltage PI [V] Flow rate command voltage QI [V]
Note 1: Since the PQ characteristics vary depending on the model, refer to the appropriate PQ characteristic chart for the
detailed output characteristics of each model.
Note 2: When the combination flow is selected (DI5 = ON), the pressure does not rise above 17.5 MPa even if the pressure
command voltage (Pi) is increased as shown in the graph above.
14
Pressure – Flow Rate Characteristics (Single pump type)
PQ chart - 1 PQ chart - 2
50 100
45
40 80
Flow rate [L/min]
SUT00S3018-30-A SUT00S5021-30-A
Maximum operating pressure = 17.6 [MPa] Maximum operating pressure = 20.6 [MPa]
Maximum flow rate = 30 [L/min] Maximum flow rate = 50 [L/min]
Command voltage = 5 [V] Command voltage = 5 [V]
PQ chart - 3 PQ chart - 4
100 100
80 80
Flow rate [L/min]
Short-time rating
60 60 Short-time rating
40 40
Continuous rating
20 Continuous rating 20
0 0
0 5 10 15 20 0 5 10 15 20 25 30
Pressure [MPa] Pressure [MPa]
SUT00S8018-30-A SUT00S5025-10-L-N0432
Maximum operating pressure = 17.6 [MPa] Maximum operating pressure = 24.5 [MPa]
Maximum flow rate = 80 [L/min] Maximum flow rate = 50 [L/min]
Command voltage = 5 [V] Command voltage = 5 [V]
PQ chart - 5
200
150
Flow rate [L/min]
Short-time rating
100
50 Continuous rating
0
0 5 10 15 20
Pressure [MPa]
SUT00S15018-10-A
Maximum operating pressure = 17.6 [MPa]
Maximum flow rate = 150 [L/min]
Command voltage = 5 [V]
15
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
PQ chart - 6 PQ chart - 7
80 100
70
80
60
Flow rate [L/min]
20 Continuous rating
Continuous rating 20
10
0 0
0 5 10 15 20 25 0 5 10 15 20
Pressure [MPa] Pressure [MPa]
SUT00S5021-20YA-N0265 SUT00S8018-21YA
Maximum operating pressure = 20.6 [MPa] Maximum operating pressure = 17.6 [MPa]
Maximum flow rate = 50 [L/min] Maximum flow rate = 80 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]
150 150
Flow rate [L/min]
Short-time rating
Short-time rating
100 100
50 50
Continuous rating Continuous rating
0 0
0 5 10 15 20 0 5 10 15 20 25
Pressure [MPa] Pressure [MPa]
SUT00S13018-10YA-N0218 SUT00S13021-11YA-N0286
Maximum operating pressure = 17.6 [MPa] Maximum operating pressure = 20.6 [MPa]
Maximum flow rate = 130 [L/min] Maximum flow rate = 130 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]
PQ chart - 10 PQ chart - 11
200 250
200
150
Flow rate [L/min]
Short-time rating
Flow rate [L/min]
Short-time rating
150
Continuous rating
100
100
50
Continuous rating 50
0 0
0 5 10 15 20 0 5 10 15 20
Pressure [MPa] Pressure [MPa]
SUT00S15018-10YA SUT00S20018-20YL-N0340
Maximum operating pressure = 17.6 [MPa] Maximum operating pressure = 17.6 [MPa]
Maximum flow rate = 150 [L/min] Maximum flow rate = 200 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]
16
Pressure – Flow Rate Characteristics (Single pump type)
PQ chart - 12 PQ chart - 13
350 350
300 300
Short-time rating Short-time rating
Flow rate [L/min]
200 200
150 150
Continuous rating Continuous rating
100 100
50 50
0 0
0 5 10 15 20 0 5 10 15 20
Pressure [MPa] Pressure [MPa]
S-SUT00S25018-10YA S-SUT00S30018-10YA
Maximum operating pressure = 17.6 [MPa] Maximum operating pressure = 17.6 [MPa]
Maximum flow rate = 250 [L/min] Maximum flow rate = 300 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]
17
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
PQ chart - 14 PQ chart - 15
35 100
Combination flow - Short-time rating
30 Combination flow - Short-time rating Independent flow -
Independent flow - 80 Short-time rating
Flow rate [L/min]
20 Independent flow - 60
Continuous rating
15 40
Combination flow - Independent flow -
10
Continuous rating Continuous rating
20
5 Combination flow -
Continuous rating
0 0
0 5 10 15 20 25 0 5 10 15 20 25
Pressure [MPa] Pressure [MPa]
SUT00D3021-30-B-N0436 SUT00D8021-30-B-N0323
Maximum operating pressure = 17.6/20.6 [MPa] Maximum operating pressure = 17.6/20.6 [MPa]
Maximum flow rate = 30/18.3 [L/min] Maximum flow rate = 80/38.4 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]
PQ chart - 16 PQ chart - 17
SUT00D13021-10-B-N0321 SUT00D15021-10-B-N0365
Maximum operating pressure = 20.6/20.6 [MPa] Maximum operating pressure = 17.6/20.6 [MPa]
Maximum flow rate = 130/47.9 [L/min] Maximum flow rate = 150/70.9 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]
PQ chart - 18
250
0
0 5 10 15 20 25 30
Pressure [MPa]
SUT00D20021-10-L
Maximum operating pressure = 11.5/25.0 [MPa]
Maximum flow rate = 200/56 [L/min]
Command voltage = 10 [V]
18
Pressure – Flow Rate Characteristics (Double pump specifications)
PQ chart - 19 PQ chart - 20
100 200
Independent flow - 50
20
Continuous rating Independent flow -
Continuous rating
0 0
0 5 10 15 20 25 0 5 10 15 20 25
Pressure [MPa] Pressure [MPa]
SUT00D8021-21YB-N0324 SUT00D13021-10YB-N0322
Maximum operating pressure = 17.6/20.6 [MPa] Maximum operating pressure = 20.6/20.6 [MPa]
Maximum flow rate = 80/38.4 [L/min] Maximum flow rate = 130/47.9 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]
PQ chart - 21 PQ chart - 22
200 250
180 Combination flow - Short-time rating
160 Combination flow - Short-time rating 200
Independent flow - Combination flow -
Flow rate [L/min]
SUT00D15021-10YB-N0358 S-SUT00D20021-12YL
Maximum operating pressure = 17.6/20.6 [MPa] Maximum operating pressure = 11.5/25.0 [MPa]
Maximum flow rate = 150/70.9 [L/min] Maximum flow rate = 200/56 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]
PQ chart - 23 PQ chart - 24
100 200
Combination flow - Short-time rating
80
150
Flow rate [L/min]
S-SUT00D8025-11YL S-SUT00D13025-11YL
Maximum operating pressure = 15.0/25.0 [MPa] Maximum operating pressure = 15.0/25.0 [MPa]
Maximum flow rate = 80/40.0 [L/min] Maximum flow rate = 130/37.3 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]
19
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
PQ chart - 25 PQ chart - 26
250 350
Combination flow - Short-time rating
Combination flow - Short-time rating 300
200
Flow rate [L/min]
S-SUT00D20025-20YL S-SUT00D30025-10YA
Maximum operating pressure = 16.5/25.0 [MPa] Maximum operating pressure = 17.5/25.0 [MPa]
Maximum flow rate = 200/56.1 [L/min] Maximum flow rate = 300/160.0 [L/min]
Command voltage = 10 [V] Command voltage = 10 [V]
20
External Dimension Diagram (Motor pump 200 V/400 V single pump type)
Suction port
(Fitted with a resin
plug at shipment)
110
Pressure sensor Suction air
128
94
57
Product nameplate
Safety valve
View A-A Motor cable wiring port
Motor nameplate
Motor cooling fan wiring port
602
264
(100) Port T 412
A 154 Encoder port
(Fitted with a vinyl 351
cap at shipment)
Discharge block
251
202.5
218
(153)
(128)
112
(88)
A 95 95 4-12 (for mounting)
Port P1 42.5 114.5 140
214
(Fitted with a vinyl cap 196
at shipment)
Geared pump
SUT00S5021-30-A
SUT00S8018-30-A
Suction air
SUT00S5021-20YA-N0265
26.2 ±0.3
129
52.4 ±0.3
SUT00S8018-21YA
D Approximate center of gravity
View A-A
Motor cooling fan, thermistor wiring port (φ21) Motor cable wiring port (φ28)
Discharge port L
321 Rc¾ 35 C 496
117 204
95.5 Relief valve 118 5 Encoder cable port
A MR-03P-3-40-56
□E
MR-03P-3-40-56
D C
NI
C
JAPAN
230
243
228
207
197
129
22.2
89
A
112
Suction
air
26.2 ±0.3
Suction port
121
129
Model code Power supply Pump L A B C D Suction Discharge Drain Pressure sensor Suction
specifications specifications port port port orientation (*1) flange
SUT00S5021-30-A 200 V Single 736 156.5 80 156 80 φ25 Rc¾ Rc¾ Front None
SUT00S8018-30-A 200 V Single 750 163.5 87 169 87 φ25 Rc¾ Rc¾ Front None
SUT00S5021-20YA-N0265 400 V Single 743 163.5 80 156 80 Rc1 Rc¾ Rc¾ Front Incorporated
SUT00S8018-21YA 400 V Single 750 163.5 87 169 87 φ25 Rc¾ Rc¾ Front None
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.
21
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
* The motor pump needs to be secured horizontally on the machine or tank. Also, secure a clearance of at least 100 mm at the suction side of the motor cooling fan.
In addition, a clearance of at least 100 mm from the pump or solenoid valve is required at the exhaust side, with good ventilation assured by mounting a cover
provided with ventilation holes or other means.
105
Suction air
151
114
76
735
289
233
207
151
132
63
A Pressure sensor
127 127 4-φ14.5 holes
Motor cooling fan
(for fixing bolts)
22
External Dimension Diagram (Motor pump 200 V/400 V single pump type)
±0.3
SUT00S13021-11YA-N0286
35.7
SUT00S15018-10YA
53
Suction air
126
149
69.9 ±0.3
A □E
D C
N
C
279
288.5
JAPAN
294
232.5
260
218
IN OUT
193
149
149
132
A
127 127 B 14.5
279 Drain port Rc¾ A 96.5 228
Discharge port Rc1 300
(plugged at factory)
Suction air
149
126
Model code Power supply Pump L A B C D E F Suction Discharge Drain Pressure sensor Suction
specifications specifications port port port orientation (*1) flange
SUT00S15018-10-A 200 V Single 858 97 63 213 110 183 163 φ38 Rc1 Rc¾ (L) None
SUT00S13018-10YA-N0218 400 V Single 850 90 55 194 103 175 155 Rc1-¼ Rc1 Rc¾ (L) Incorporated
SUT00S13021-11YA-N0286 400 V Single 850 90 55 194 103 175 155 Rc1-¼ Rc1 Rc¾ (L) Incorporated
SUT00S15018-10YA 400 V Single 858 97 63 213 110 183 163 φ38 Rc1 Rc¾ (L) None
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.
SUT00S20018-20YL-N0340
Suction air
103
151
57
MADE IN JAPAN
279.5
TUO
N
236
151
132
132
114
80
63
A
14.5 4-φ14.5 holes (for fixing bolts)
127 127 96.5 228 M12 bolts recommended
254
Pressure sensor
23
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
* The motor pump needs to be secured horizontally on the machine or tank. Also, secure a clearance of at least 100 mm at the suction side of the motor cooling fan.
In addition, a clearance of at least 100 mm from the pump or solenoid valve is required at the exhaust side, with good ventilation assured by mounting a cover
provided with ventilation holes or other means.
D
C
View A-A
Discharge block
Safety valve Exhaust air
B
Pressure sensor
Direction of motor rotation
Motor/AC fan terminal box
Motor/AC fan terminal box A 459 L
(For -YAR and -YLR 280 A 874
specifications)
95 181 140
361
Discharge Discharge
20
port 1 port 2
S-SUT00S25018-10YA (R) (Specifications with terminal box at the left side, viewed from the pump)
A 99 157
Suction port
Rc 2
OIL HYDRAULIC PUMP
MOD NO PDK03156-**
DAIKIN HYDRAULICS(SUZHOU)CO.,LTD.
361
Drain port
Rc¾
180
358
Model code Power supply Pump L A B C D Suction Suction Discharge Discharge Drain Pressure sensor Suction
specifications specifications port 1 port 2 port 1 port 2 port orientation (*1) flange
S-SUT00S25018-10YA 380 V Single 1246 372 201 178 118 Rc2 — Rc1-½ — Rc¾ Top Incorporated
S-SUT00S30018-10YA 380 V Single 1405 531 360 175 115 Rc2 Rc1-½ Rc1-¼ Rc1-¼ Rc¾ Top Incorporated
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.
24
External Dimension Diagram (Motor pump 200 V/400 V double pump type)
180
Geared pump Suction flange Motor
Suction port
(Fitted with a resin plug at shipment)
110
Suction air
Pressure sensor
115
128
57
Product nameplate
264 592
154 412
218
202.5
153
112
95
196
25
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
* The motor pump needs to be secured horizontally on the machine or tank. Also, secure a clearance of at least 100 mm at the suction side of the motor cooling fan.
In addition, a clearance of at least 100 mm from the pump or solenoid valve is required at the exhaust side, with good ventilation assured by mounting a cover
provided with ventilation holes or other means.
99
Suction air
129
136
SOLb
89
Motor cooling fan, thermistor wiring port (φ21) Motor cable wiring port (φ28)
JAPAN
MADE IN
228
243
207
IN OUT
179
179
129
129
Suction air
149
136
SOLb
D
F Motor
View A-A
Terminal box nameplate Motor
Motor cooling fan, thermistor wiring port cooling fan
Solenoid valve Motor wiring port
366 KSO-G03-20BP-20-EN Discharge port Rc1
Approximate center of gravity
148 218 L
112 C 586
Discharge block
Pressure 89 E
sensor Encoder
A connector
358
288.5
JAPAN
279
232.5
231
IN OUT
218
199
149
149
132
104
Model code Power supply Pump L A B C D E F Suction Discharge Drain Pressure sensor Suction
specifications specifications port port port orientation (*1) flange
SUT00D13021-10-B-N0321 200 V Double 806 169 31 220 103 131 169 Rc1-¼ Rc1 Rc¾ (L) Incorporated
SUT00D15021-10-B-N0365 200 V Double 815 177 39 228 110 139 177 Rc1-½ Rc1 Rc¾ (L) Incorporated
SUT00D13021-10YB-N0322 400 V Double 703 169 31 220 103 131 169 Rc1-¼ Rc1 Rc¾ (L) Incorporated
SUT00D15021-10YB-N0358 400 V Double 815 177 39 228 110 139 177 Rc1-½ Rc1 Rc¾ (L) Incorporated
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.
26
External Dimension Diagram (Motor pump 200 V/400 V double pump type)
105
Suction air
103
C
99
151
E
Motor cooling fan
D Motor nameplate
Suction flange Terminal box
Motor wiring port
View A-A Motor cooling fan, thermistor wiring port
288.5
JAPAN
279
288
232.5
240
151
132
113.6
A
127 127 B 4-φ14.5 holes (for fixing bolts)
279 A 96.5 228 M12 bolts recommended
Discharge port 2 Rc1
300
Discharge port 1 Rc1
99
Model code Power supply Pump L A B C D E Suction Suction Discharge Drain Pressure sensor Suction
specifications specifications port 1 port 2 port port orientation (*1) flange
Incorporated
SUT00D20021-10-L 200 V Double 814 131.6 68.6 232 131.6 68.6 Rc1-¼ Rc1-¼ Rc1 Rc1 Top (2 pcs.)
Incorporated
S-SUT00D20021-12YL 400 V Double 819 131.6 68.6 232 131.6 68.6 Rc1-¼ Rc1-¼ Rc1 Rc1 Top (2 pcs.)
S-SUT00D13025-11YL 400 V Double 799 116 59 212 — 59 Rc1-¼ — Rc1 Rc1 Top Incorporated
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.
Suction air
98
103
131.1
113
91.1
95.6
Approximate Product nameplate
226.5 Geared pump center of gravity
Motor nameplate
View A-A Terminal box
Motor cooling fan, thermistor wiring port (φ21) Motor cable wiring port (φ28)
Discharge port Rc¼
(plugged at factory) 722.6
321 496
117 204 Encoder connection
226.5 5 Connector
A 185.2
Discharge
95.6
block
MADE IN JAPAN
Discharge
block
243
228
OUT
N
207
131.1
94
Pressure
A
sensor
108 108 Discharge port PH 228 4-φ14.5 holes (for fixing bolts)
241 Rc1 275 M12 bolts recommended
Discharge port PL
Rc1
Power supply Pump Suction Discharge Discharge Pressure sensor Suction
Model code specifications specifications port port PH orientation (*1) flange
port PL
S-SUT00D8025-11YL 400 V Double Rc1-¼ Rc1 Rc1 Bottom Incorporated
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.
27
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
* The motor pump needs to be secured horizontally on the machine or tank. Also, secure a clearance of at least 100 mm at the suction side of the motor cooling fan.
In addition, a clearance of at least 100 mm from the pump or solenoid valve is required at the exhaust side, with good ventilation assured by mounting a cover
provided with ventilation holes or other means.
105
Suction air
103
99
151
65
896
366.5 228 667 Encoder connector
(148.5) (218) 128
Pressure
sensor 65
A
279.5
288.5
236
151
132
114
7
127 127 Discharge port PL Rc1 96.5 228 4-φ14.5 holes
(for fixing bolts)
254 M12 bolts recommended
Discharge block
View A-A
Discharge block
Safety valve
360
Pressure sensor
Direction of motor rotation
Motor/AC fan terminal box
A
459 1405
Motor/AC fan terminal box
280 531 874
(For -YAR and -YLR
specifications) 95 181 140
361
Rc1-¼ Rc1-¼
A 4-φ15 125 80
279 445 Encoder terminal box
(M14 bolts recommended) 90
358
Power supply Pump Suction Suction Discharge Discharge Pressure sensor Suction
Model code specifications specifications port 1 port 2 port 1 port 2 Drain port orientation (*1) flange
S-SUT00D30025-10YA 380 V Double Rc2 Rc1-½ Rc1-¼ Rc1-¼ Rc¾ Top Incorporated
(*1) “Pressure sensor orientation” indicates the orientation of the pressure sensor viewed from the pump side.
28
External Dimension Diagram (Controller 200 V/400 V single/double pump type)
200 V, 30 to 200 L/min, 17.6 MPa, 20.6 MPa, 24.5 MPa (Single/double pump)
400 V, 50 to 200 L/min, 17.6 MPa, 20.6 MPa, 24.5 MPa (Single/double pump)
Cooling fan
View A-A (bottom face)
Vent
180
φ8 (M6 mounting bolt recommended)
Cooling fan
10
exhaust air
Monitor display
34
I/O terminal block (Normally showing the pressure in MPa)
M3 screws
FG
FG
+5V
GND
Z-
Setting keys (four keys)
Z+
B-
B+
A-
A+
THM-
THM+
Product nameplate
AGND
AO2
(QO)AGND
AO1
(PO)
AGND
AIN2
(QI) AGND
AIN1
(PI) AGND
P_S
233
A5V
ALM_C
ALM_B
ALM_A
DOCOM
DO7
DO6
DO5
DO4
DO3
361
H1
DO2
H2
DO1
DI8
DI7
DI6
DI5
DI4
DI3
DI2
DI1
DICOM
DGND
RxD
TxD
FG
FG
Controller nameplate
L1 L2 L3 P1 P2 B1 B2 U V W
95.5
A A suction air
230 207
M6 screw
(for ground connection)
240 212
29
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
* The controller needs to be mounted vertically on a wall inside the electrical cabinet, with a clearance of at least 100 mm
secured above and below and a clearance of at least 30 mm for wiring and maintenance at the left and right.
SUT00S20018-20YL-N0340
Cooling fan
View A-A (bottom face)
Vent
pressure in MPa)
25
FG
Setting keys (four keys)
FG
GND
+5V
Z-
Z+
B-
B+
A-
A+
THM-
THM+
AGND
AO2
(QO)AGND
AO1
Product nameplate
(PO)
AGND
AI2
(QI) AGND
236.5
AI1
(PI) AGND
P_S
A5V
ALM_C
ALM_B
ALM_A
DOCOM
DO7
DO6
DO5
DO4
DO3
DO2
DO1
DI8
DI7
415
398
371
DI6
DI5
DI4
DI3
DI2
DI1
DICOM
DGND
RxD
TxD
FG
FG
TOKYO JAPAN
L1 L2 L3 P1 P C U V W
TS-808B
137
DAIKIN
PMCAMB2A□-10
MFG No.::
****-**-******
400V
INPUT : 3PH 380-440V 50/60Hz 37.5A
:
:
MASS : kg
DAIKIN INDUSTRIES, LTD. MADE IN JAPAN
M8 screws
(For grounding)
— —
↑ ↑ Cooling fan
A 17 226 (17) A 42
19
(6)
suction air
260 238
270 240
Controller nameplate
S-SUT00D8025-11YL
Vent
Monitor display
34
(Normally showing
FG
FG
GND
the pressure in MPa)
+5V
Z-
Z+
B-
B+
A-
A+
THM-
THM+
AGND
AO2
(QO)AGND
AO1
(PO)
AIN2
AGND
(QI) AGND
AIN1
(PI) AGND
Setting keys (four keys)
Hp
P_S
Product nameplate
A5V
ALM_C
ALM_B
ALM_A
DOCOM
DO7
DO6
DO5
DO4
H2
DO3
H1
Ht
DO2
DO1
DI8
DI7
DI6
DI5
DI4
DI3
DI2
DI1
DICOM
DGND
RxD
TxD
FG
FG
L1 L2 L3 P1 P2 B1 B2 U V W
95.5
DAIKIN
PMCAMA1A-10
MFG No.:: ******-******
Main circuit
400V
INPUT : 3PH 380-440V 50/60 Hz A
:
:
terminal block
MASS : kg
MADE IN JAPAN
M6 screws
— —
↑ ↑
6
17
Cooling fan
A 25 180 (25) A 38.8
Controller nameplate suction air
230 207
240 212
30
External Dimension Diagram (Controller 400 V single/double specifications)
* The controller needs to be mounted vertically on a wall inside the electrical cabinet,
with a clearance of at least 100 mm secured above and below and a clearance of at
least 30 mm for wiring and maintenance at the left and right.
Vent
25
Setting keys (four keys)
FG
FG
GND
+5V
Z-
Z+
B-
B+
A-
A+
THM-
THM+
AGND
AO2
(QO)AGND
AO1
(PO)
AGND
AI2
236.5
(QI) AGND
AI1
(PI) AGND
P_S
A5V
ALM_C
ALM_B
ALM_A
DOCOM
DO7
DO6
DO5
DO4
DO3
DO2
415
398
DO1
371
DI8
DI7
DI6
DI5
DI4
DI3
DI2
DI1
DICOM
DGND
RxD
TxD
FG
FG
TOKYO JAPAN
TS-808B
137
DAIKIN
PMCAMB2A□-10
MFG No.::
****-**-******
V
INPUT : 3PH 380-440V 50/60 Hz A
:
:
MASS : kg
MADE IN JAPAN
M8 screws (left/right)
(For grounding)
— —
↑ ↑
A Cooling fan
(6)
17 (17) A
19
226 42 suction air
260 238
270 240
380 V 250 L/min 17.6 MPa, 300 L/min 17.6 MPa (Single pump)
380 V 300 L/min 25 MPa (Double pump)
Wiring port (power supply, regenerative brake unit)
S-SUT00S25018-10YA Wiring port (motor side)
Vent U V W Signal line wiring port
S-SUT00S30018-10YA
S-SUT00D30025-10YA
PE R S T P1 P+ N-
Cooling fan
View A-A (bottom face)
Display
Setting keys
Hp
Ht
H
(four keys)
31
ss
it
un
rne
This is a list of electrical components required for SUPER UNITs.
ha
ke
r
ss
The list shows the model code and quantity for each of the electrical
ra
nso
rne
r
eb
components that are contained in each set model code, that need to be
r
e
re
ha
tiv
re
ilte
ce e
cto
r
co
ordered separately, and that are contained in each S-SUT model code.
es
co
era
ef
an tiv
de
sur
ite
rea
g
is
en
s
co
ist ra
rr
g
No
Re
En
(*1) Electrical component model code fields marked with (*1) show a part
Rin
DC
Pre
Fe
res gene
Re
code instead of a model code.
(*2) Rows assigned a set model code show the electrical components among those
required for the SUPER UNIT that are contained in the set, and the quantity of
each component. Please order them separately from the SUPER UNIT.
(*3) Rows with the indication “To be ordered separately” show the electrical
components that are required, in addition to the electrical components
contained in the set, to satisfy electromagnetic compatibility (EMC).
Please order them separately.
Specifications
(*4) Rows with the indication “Electrical components provided with the product” show
0.5 mH, 55 A
1.9 mH, 27 A
1.0 mH, 55 A
30 A, M6 terminal
30 Ω, 500 W
60 Ω, 500 W
10 Ω, 500 W
20 Ω, 500 W
68 Ω, 500 W
8Ω, 4.5 kW
85 A
5 m, with ferrite core 1T
5 m, with ferrite core 2T
5 m, with ring core 3T
5 m, with ring core
10 m, with ring core
5 m, with ring core
9-pin, 5 m
12-pin, 5 m
9-pin, 10 m
5m
50 A
60 A, Soshin Electric Co.,Ltd.
Okaya Electric Industries Co.,Ltd.
75 A, FN3011-75-62
50 A, FN3025HP-50-72
the electrical components that are provided as accessories to a product ordered φ74 × φ46
by specifying an S-SUT model code. To satisfy electromagnetic compatibility
(EMC), electrical components shown in the corresponding “To be ordered
separately” row in the table will be required, so please order them separately.
(*5) Noise filter PM-SNF04 can be ordered in place of PM-SNF02.
(*6) The regenerative resistors (2 pcs.) of SUT00S5025-10-L-N0432 are 1 kW
specifications. When using the unit for applications with high regenerative
model code
load factors, additional regenerative resistors will be required.
Electrical component
Electrical component ordering
SUT (S-SUT) Model code
PM-SDL03
PM-SDL04
PM-SDL05
PM-SDL06
PM-RB02
PM-RB03
PM-RB04
PM-RB05
PM-RB06
SB-PP03159-05 (*1)
SB-PP03158-03 (*1)
PM-SPH05
PM-SPH05-001
PM-SPH05-002
PM-SPH05-003
PM-SPH10
SB-PP03151-01 (*1)
PM-SEH05-P22-A09R
PM-SEH05-P22-A12R
PM-SEH10-P22-A09R
SB-PP03706-01 (*1)
PM-SNF01
PM-SNF02
PM-SNF03
PM-SNF04
PM-SNF07
PM-SRC01
PM-SRC02
SB-PP03404-02 (*1)
PM-FC01
PM-FC04
PM-FC05
200 V
List of Electrical Components
400 V
Model code for set order PM-SOP12 1 6 1 1
SUT00S20018-20YL-N0340
To be ordered separately (*3) 2 2 2
S-SUT00S25018-10YA Electrical components provided with the product (*4) 1 1 1 1 1 1
S-SUT00S30018-10YA Electrical components provided with the product (*4) 1 1 1 1 1 1
SUT00D3021-30-B-N0436 Model code for set order PM-SOP15 1 2 1 1 1 1 1
SUT00D8021-30-B-N0323 Model code for set order PM-SOP16 1 3 1 1 2 1 1
200 V
SUT00D13021-10-B-N0321 Model code for set order PM-SOP10 1 6 1 1 (*5)
SUT00D15021-10-B-N0365
SUT00D20021-10-L To be ordered separately (*3) 2 or 2 1 1 1 1
Model code for set order PM-SOP04 1 2 1 1
SUT00D8021-21YB-N0324
To be ordered separately (*3) 1 3 1
32
List of Electrical Components/External Dimension Diagrams (Controller)
33
Ring core (2 turns)
SUPER UNIT controller *1 Filter board *1 Filter board *1
M3
1 L1
FG S L1 S L1
25 L2
FG R L2 R L2
2 L3
GND T L3 T L3
26 E
+5V PE PE
3
Z-
27
Z+ Encoder
4
B-
28 200 V 50 Hz, 200/220 V 60 Hz
0.3 mm2 (AWG 22) or greater B+
5 0.5 mm2 (CE cable) Max. 23.2 kVA
A-
29 0.5 mm2 (VCT cable) Recommendation Breaker capacity 50 A
A+
6 Power supply cable 6 mm2 (CE cable)
THM+ Motor
30 2.0 mm2 (CE cable) 8 mm2 (VCT cable)
THM- thermistor
7 1.5 mm2 (VCT cable)
AGND M6
* Flow rate monitor 31 Flow rate monitor Regenerative resistor*2 L1
QO
8 (30 Ω × 3) 200 V 50 Hz
AGND L2
* Pressure monitor 32 Pressure monitor 200/220 V 60 Hz
PO E
9
AGND
Flow rate command 33 Flow rate command L1
QI Main power
10 L2
AGND supply
Pressure command 34 Pressure command L3
PI DC AC FAN
11 DC P1
AGND reactor AC
Reactor P2 *2 SUPER UNIT motor pump
35 FAN
P_S Pressure sensor
12 Regenerative B1
+5V resistance
36 B2
ALM_C When power OFF, at alarms U
13 U
Alarm monitoring ALM_B ALM_B V
37 During normal operation Motor V
ALM_A W M
ALM_A W
0.3 mm2 (AWG22) 14
DOCOM(0V)
or more 38
DO7
15 THM
DO6
39 Th
Controller at Ferrite core *1 DO5
16 Unassigned 2
the machine side 4 mm (CE cable)
Controller side, DO4
40 5.5 mm2 (VCT cable)
simultaneous DO3
clamping of 17 1 A+
DO2
Operation possible thermistor and 41 2 A-
encoder DO1
without the items 18
DI8 3 B+
marked with *
42 4 B-
DI7
19 5 Z+
DI6 Encoder
43 6 Z-
DI5 Unassigned
20 7 +5V
DI4
44 8 GND
DI3
21 9 FG
DI2
45
* Motor DI1 Start/stop (Open: automatic control)
start/stop 22
DICOM (+24 V) AGND
46 1
DGND P_S
* Serial 23 2 Pressure Pump
RXD For Hybrid-Win +5V sensor
communication 47 3 model
TXD
0.3 mm2 (AWG22) 24
FG
or more 48
FG
Ring core
(5 turns)
(Provided at the pressure sensor side of the pressure sensor harness)
Electric Wiring Diagram (Example with 200 V single pump type SUT00S5021 and SUT00S8018)
M3 SUPER UNIT controller
Noise filter
25
FG
2 R
GND 4 1
26 S
+5V 5 2
3 T
Z- 6 3
27 E
Z+ Encoder
4 *1 *1
B-
28 Ring core 2 (2 turns)
2
0.3 mm (AWG22) or more B+ (At the controller side) 3-phase AC 380 to 440 V
5
A- ,50 Hz/60 Hz
29 *1
A+ *1 Ring core 1 (5 turns)
Ferrite core Max. 34.8 kVA
6 (At the AC fan side)
THM- Motor thermistor Recommendation Breaker capacity 40 A
30 (At the controller side)
THM+ (No polarity)
7 Power supply cable
AGND Regenerative R 6 mm2 (70°C cable)
* Flow rate monitor 31 Flow rate monitor
QO resistance N 14 mm2 (60°C cable)
8 (68 Ω × 4)
AGND E
* Pressure monitor 32 Pressure monitor
PO M6
9
AGND 1-phase AC 215 to 245 V
Flow rate command 33 Flow rate command
QI ,50 Hz/60 Hz
10 1 2
AGND 0.5 mm (70°C cable)
Pressure command 34 Pressure command L1
PI Main power 2 0.5 mm2 (60°C cable)
1 supply L2
FG 3
11 L3
AGND 4 AC FAN
35 P1 DC
P_S Pressure sensor DC reactor 5 reactor *2 AC
12 P2
+5V 6 FAN SUPER UNIT motor pump
36 Regenerative B1
ALM_C resistance 7
13 B2
Alarm signal ALM_B When power OFF, at alarms 8 U
37 U
ALM_A ALM_B 9 V
Motor wiring V
14 During normal operation 10 W
DOCOM (0V) M
38 ALM_A W
DO7
15
0.3 mm2 (AWG 22) DO6
39 THM
Machine side or greater DO5
16 *1 *1 Th
controller DO4 Warning output Ferrite core Ferrite core
40
DO3 (At the controller side) (At the motor
17 side)
DO2
Operation possible 41
DO1 Ready to operate *1 1 A+
without the items 18
DI8 Ring core 2 (2 turns)
marked with * 2 A-
42 (At the controller side)
DI7 3 B+
19
DI6 4 B-
43 10 mm2 (70°C cable)
DI5 14 mm2 (60°C cable) 5 Z+
20 Encoder
DI4 6 Z-
44
DI3 7 +5V
21
DI2 8 GND
45
DI1 Start/stop (Set in start status upon input of DC 24 V power) FG
Motor start/stop 22 9
DICOM (DC+24 V)
46
DGND
23 AGND
*Serial communication RXD For servicing 1
47 P_S Pressure
TXD 2 Pump
2
0.3 mm (AWG 22) 24 +5V sensor model
FG 3
or greater 48
FG
Electric Wiring Diagram (Example with 400 V single pump type SUT00S13018)
Ring core 1
(3 turns)
(At the pressure sensor side)
SUPER UNIT
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
34
35
Ring core (2 turns)
SUPER UNIT controller *1 Filter board *1 Filter board *1
M3
1 L1
FG S L1 S L1
25 L2
FG R L2 R L2
2 L3
GND T L3 T L3
26 E
+5V PE PE
3
Z-
27
Z+ Encoder
4
B-
28 200 V 50 Hz, 200/220 V 60 Hz
0.3 mm2 (AWG 22) or greater B+
5 0.5 mm2 (CE cable) Max. 23.2 kVA
A-
29 0.5 mm2 (VCT cable) Recommendation Breaker capacity 50 A
A+
6 Power supply cable 6 mm2 (CE cable)
THM+ Motor 2
30 2.0 mm (CE cable) 8 mm2 (VCT cable)
THM- thermistor
7 1.5 mm2 (VCT cable)
AGND M6
* Flow rate monitor 31 Flow rate monitor Regenerative resistance*2 L1
QO
8 (30 Ω × 3) 200 V 50 Hz
AGND L2
* Pressure monitor 32 Pressure monitor 200/220 V 60 Hz
PO E
9
AGND
Flow rate command 33 Flow rate command L1
QI Main power supply
10 L2
AGND
Pressure command 34 Pressure command L3
PI AC FAN
11 DC P1 DC
AGND Reactor AC SUPER UNIT motor pump
35 P2 reactor *2
P_S Pressure sensor FAN
12 Regenerative B1
+5V resistance
36 B2
ALM_C When power OFF, at alarms U
13 U
Alarm monitoring ALM_B ALM_B V
37 During normal operation Motor V
ALM_A W M
ALM_A W
0.3 mm2 (AWG22) 14
DOCOM(0V)
or more 38
DO7
15 THM
DO6
39 Th
Machine side Ferrite core *1 DO5
16 4 mm2 (CE cable)
controller Controller side DO4
simultaneous clamping 40 5.5 mm2 (VCT cable)
DO3
of thermistor and encoder 17 1 A+
DO2
Operation possible 41 2 A-
DO1 Ready to operate
without the items 18
DI8 3 B+
marked with *
42 4 B-
DI7
19 5 Z+
DI6 Encoder
43 6 Z-
DI5 Pump capacity selection input
20 7 +5V
DI4
44 8 GND
DI3
21 9 FG
DI2
45
DI1 Start/stop (Open: automatic control)
* Motor start/stop 22
DICOM (+24 V)
46 1 AGND
DGND P_S
* Serial 23 2 Pressure Pump
communication RXD For Hybrid-Win +5V sensor
47 3 model
TXD
0.3 mm2 (AWG22) 24
FG
or more 48
FG
(Provided at the
pressure sensor side
of the pressure
0.3 mm2 (AWG 22) or greater sensor harness) SOL+
Solenoid valve
Electric Wiring Diagram (Example with 200 V double pump type SUT00D8021)
Ring core 1
(3 turns)
0.3 mm2 (AWG 22) or greater
(At the pressure sensor side)
Electric Wiring Diagram (Example with 400 V double pump type SUT00D13021)
SOL+
SOL Solenoid valve
SOL-
SUPER UNIT
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
36
37
Ring core (2 turns)
SUPER UNIT controller Noise filter
M3
25 L1
FG R L1
2 L2
GND S L2
26 L3
+5V T L3
3 E
Z- PE
27
Z+ Encoder
4 <Options> *1 <Options> *1
B-
28
0.3 mm2 (AWG22) or more B+
5
A-
29 Ring core (5 turns)
A+
6
THM+
30 Thermistor
THM- (No polarity) L1
7
AGND N 215 to 245 V
* Flow rate monitor 31 Flow rate monitor
QO E /50 to 60 Hz
8 M5
AGND
* Pressure monitor 32 Pressure monitor
PO
9 Regenerative resistance
AGND <Options> *1
Flow rate command Flow rate command (68 Ω × 2) 0.5 mm2 (CE cable)
33 1
QI
10 L1 0.5 mm2 (VCT cable)
AGND 2
Pressure command 34 Pressure command L2
PI 3
L3
4
11 P1 DC AC FAN
AGND DC reactor 5
P2 reactor
35 6 AC SUPER UNIT
P_S Pressure sensor 47 W
12 B1 FAN motor pump
+5V Regenerative resistance 7
36 B2
ALM_C 8
13 When power OFF, at alarms U U
Alarm monitoring ALM_B 9
37 ALM_B Motor power cable V V
ALM_A During normal operation 10
0.3 mm2 14 W W M
0V ALM_A
(AWG22) or greater 38 Ferrite core
DO7 Ring core (2 turns)
Ferrite core 15 <Options>*1
DO6 <Options>*1 THM
39
Machine side DO5
16 Th
controller DO4 Warning output
40 8 mm2 (VCT cable)
DO3 6 mm2 (CE cable)
17 1 A+
DO2
Operation possible 41 2 A-
without the items DO1 Ready to operate
18 3 B+
marked with* DI8
42 4 B-
DI7
19 5 Z+
DI6 Encoder
Pump combination flow 43 6 Z-
DI5 Pump capacity selection input
selection signal 20 7 +5V
DI4
44 8 GND
DI3
21 9 FG
DI2
45
DI1 Start/stop (Set in start status upon input of DC 24 V power)
* Motor start/stop 22
+24 V 1 AGND
46 P_S Pressure
DGND 2 Pump
* Serial communication 23 +5V sensor model
RXD For servicing 3
47
TXD
0.3 mm2 24
FG
(AWG22) or greater 48
FG
Solenoid valve
SOL-
SOL
16 mm2 (70°C cable) * Linear filter with increased
38 mm2 (60°C cable) overload durability recommended
38
39
35 mm2 or greater
*7 SUPER UNIT controller
Ferrite core M8
Controller at the 3 turns
machine side (At the controller side) PQ control board PE
X1 R 3-phase AC 380 V
1 R
+24V Main power S , 50 Hz/60 Hz
+24 V power supply 2 Control power S
GND supply T
T Rated capacity 83 kVA
(DC+24 V 0.2 A) Shorting bar PE Recommended breaker capacity 200 A
*3 P1
X2
Regenerative P+
brake unit N-
Not used 35 mm2 or greater Regenerative resistor unit (4.5 kW, 8 Ω)
0.3 mm2
(AWG22) TH1
X3 R1
1 *5
PI Analog command input TH2
Pressure command 2 QI PI: Pressure command R2 1-phase 230 V
Flow rate command 3 Regenerative brake unit (85 A)
GND QI: Flow rate command E
4 50 Hz 0.6 A
*4 FG TH+ DB 60 Hz 0.68 A
5 Motor thermistor
TH- *6 P+ M6
P+ 0.5 mm2 or greater
X4
1 N-
DOCOM (DC+24 V/0 V) PE
Alarm signal 2 DO1 Alarm output
3 DO2 (Flow rate selection signal output)
4 TA
DO3 (Reserved output) AC
TB
FAN SUPER UNIT
TC
X5 motor pump
1 DICOM (DC+24 V/0 V)
Start/stop 2 35 mm2 or greater
DI1 Start/stop
*1 0V/DC+24 V 3 DI2 Regenerative brake alarm M8
4 DI3 Regenerative resistor alarm M8
5 U U
DI4
6 Motor V V M
DI5
7 (16-step PQ selection input) W W
DI6
8 DI7
Ring core 2
CN3 2 turns
(At the controller side)
Terminal block for servicing *7 Th
(right side of the operation panel display)
CN1 1 A+
AGND 2 A-
P_S Pressure sensor 3 B+
+5V 0.3 mm2 4 B- Encoder
FG (AWG20) 5 +5V
6 GND
CN2 7 FG
GND 8 Blank
+5V
B-
B+ Encoder AGND
0.3 mm2 1
A- P_S Pressure
(AWG22) 2 Pump
A+ Ring core 1 +5 V sensor
3 model
FG 5 turns
(At the pressure
sensor side)
SUPER UNIT
Memo
40
8-PQ Control
NO
41
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
The following table shows the settings and details of parameters given in “Control Method
Selection Procedure for Analog Command Input Type SUPER UNITs (SUT/S-SUT)”. (For details,
please refer to the instruction manuals for the analog command input type and for the 8-PQ control
type.)
H53 CD_T Combination flow hold time 0.3 combination ⇒ independent pump selection, immediately after
independent ⇒ combination pump selection
Pump combination flow Time to maintain combination flow after starting the pumps from the
H55 SD_T 0.1 stopped state or standby state
hold time at startup
Note 1: “*” in PH*, QH*, PL* and QL* in the above table represents a PQ number from “0” to “7”.
42
Example Control
* The following shows example waveforms while controlling the pressure and flow rate on press machine a
SUPER UNIT incorporated.
Example with S-SUT00D20025-12YL (Pmax = 25 MPa (independent), Qmax = 200 L/min (combination), 400 V specifications)
600 Qi
Qo
Pi Po
Pi
Qo
400
Po
Po
200 Qi Qo
20
0 20,000 40,000 60,000 80,000 100,000 120,000
-200
time [ms] Pressure = 25 MPa/10 V (Independent)
Flow rate = 200 L/min/10 V (Combination)
Example with SUT00D15021-10-B (Pmax = 20.7 MPa (independent), Qmax = 150 L/min (combination), 200 V specifications)
200 Qo
Qo
43
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
The following shows an operation example using five setting patterns by setting the pressure and flow rate for
each process for PQ numbers 0 to 4, corresponding to PQ setting charts 1 to 5 .
(In this example, the selection of combination/independent flow is controlled from the machine using an
external signal (DI5).)
1 PQ setting
Selecting combination flow [L/min]
200
180
QL1
160
Cylinder position mm
140
Selecting independent flow 120
100
80
Selecting
60
independent
flow 40 QH2
20 PL1 PH2
0 [MPa]
Time (sec) 0 5 10 15 20 25
140 QL2
120
2 5 2 5 100
5
80
60 QH2
40
Time (sec) 20 PL2 PH2
0
0 5 10 15 20 25
3
3 PQ setting
Control pressure MPa
[L/min]
200
180
160
140 QL3
120
Time (sec) 100
80
60 QH3
40
20 PL3 PH3
Standby 0
Press 1 Standby
0 5 10 15 20 25
Down (high speed) Up (low speed)
Press 2 4 PQ setting
[L/min]
Down (low speed) Up (high speed) 200
Pressure release 180
160 QL4
140
120
[L/min]
200 100
Maximum control range for combination flow 80
60
40 QH4
150 Maximum control 20 PL4 PH4
QL* range for independent 0 [MPa]
Example Control: Timing Chart of a Press
flow 0 5 10 15 20 25
100
5 PQ setting
[L/min]
200
QH* 50 180
160
140
0 [MPa] 120
0 5 10 15 20 25 100
80
PH* PL*
60
8-PQ Setting Example with SUT00D15021-10-B-N0365 40 QL0
20
Up to eight patterns of the flow rate for combination flow (QL*), pressure for QH0
[MPa]
0
combination flow (PL*), flow rate for independent flow (QH*) and pressure for 0 5 10 15 20 25
independent flow (PH*) can be set using parameters. The PQ settings shown in
the charts to the right are the example setting patterns applied to each of the indicates an example operating point when
operating ranges in the figures above. combination flow is selected.
indicates an example operating point when
independent flow is selected.
44
Example Timing Chart for Cylinder Operation and Signals on a Press
Example of 8-PQ Function: Example Timing Chart with SUT00S/S-SUT00S (Single Pump, 8-PQ Type)
Q3
Flow rate
setting Q6 Speed Q5
Q1 Q2 Q7 Q4
Q0 Q0 Q0
Pressure (P) (thrust)
P1 P3 P6 P7 P5 P4
P2
Pressure setting
P0
P0 P0 Time
Load pressure Contacting the workpiece
Preparing for
operation 1 Cycle
DI-3
Pressure/speed setting
DI-4
Pattern selection signal
DI-6
Digital Selection Signals and PQ Numbers PQ Numbers and Example Pressure/Flow Rate Settings
DI-3 DI-4 DI-6 Pattern No. PL* [MPa] QL* [L/min]
off off off PQ0 PQ0 0.5 0.0
on off off PQ1 PQ1 16.0 10.0
off on off PQ2 PQ2 12.0 8.0
on on off PQ3 PQ3 16.0 70.0
off off on PQ4 PQ4 16.0 6.0
on off on PQ5 PQ5 16.0 80.0
off on on PQ6 PQ6 17.6 50.0
on on on PQ7 PQ7 16.0 10.0
Note: The analog command input type is selected by the default parameter settings of SUT/S-SUT before shipment. (Parameter P31 (command input target selection) is
set to “0: Analog input”.)
The setting of parameter P31 needs to be changed to “2: Digital input (8-PQ)”. (The setting change takes effect upon restarting the power.)
To achieve shockless control on a machine, the flow rate, pressure, response time and other settings need to be adjusted according to the machine.
45
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
Example Timing with 8-PQ, Double Pump, External Signal (DI5) Selection Specifications
Flow rate (Q) (speed)
Up
Press 1 Press 2 Stop (high speed) Stop
Q3
Flow rate setting Q6 Speed Q5
Q1 Q2 Q7 Q4
Q0 Q0 Q0
P6 P7 P5 P4
Pressure (P) (thrust)
P1 P3 P2
Pressure setting
P0
P0 P0 Time
Load pressure Contacting the workpiece
DI-3
Pressure/speed setting
DI-4
Pattern selection signal
DI-6
Selecting combination flow DI-5
Pump flow rate selection status Combination (low pressure) Independent (high pressure) Combination (low pressure) Independent
Digital Selection Signals and PQ Numbers PQ Numbers and Example Pressure/Flow Rate Settings
DI-3 DI-4 DI-6 Pattern No. PH* [MPa] QH* [L/min] PL* [MPa] QL* [L/min] PC*
off off off PQ0 PQ0 1.0 5.0 1.0 10.0 1
on off off PQ1 PQ1 20.6 30.0 12.0 50.0 1
off on off PQ2 PQ2 20.6 30.0 18.0 30.0 1
on on off PQ3 PQ3 20.7 30.0 12.0 130.0 1
off off on PQ4 PQ4 20.6 30.0 14.0 30.0 1
on off on PQ5 PQ5 20.6 30.0 18.0 130.0 1
off on on PQ6 PQ6 17.0 40.0 17.6 40.0 1
on on on PQ7 PQ7 20.6 30.0 18.0 50.0 1
Note: This example shows operation of SUT00D13021 (200 V specifications) with 8-PQ type and flow rate selection by external signal (DI5) selected.
Flow rate selection by the 8-PQ function can also be used in the autonomous selection mode. For details on the 8-PQ control, please refer to the instruction
manual provided separately.
To achieve shockless control on a machine, the flow rate, pressure, response time and other settings need to be adjusted according to the machine.
46
Maintenance/Management Tool (Hybrid-Win)
Hybrid-Win is a software tool that connects your personal computer running Windows 7/8 to a SUPER UNIT through communications (RS232C) P C t o o l
to enable editing/saving of SUPER UNIT parameters and measurement of waveforms that result from the pressure/flow rate control.
Hybrid–win and its instruction manual are available from the website (http://www.daikinpmc.com) after registering as a member.
A personal computer and an RS232C/USB conversion cable are necessary.
47
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
❶ [Alarm history]
The window displays details on the latest 10 alarms.
Information on the alarms including the alarm number and the total
❷ operating time at the occurrence of the alarm can be checked in the
table as shown in the figure to the left. The data can also be saved
as Excel data or in other formats.
48
External/Installation Dimension Diagrams for Electrical Components
DC Reactor
PM-SDL03 PM-SDL04
112 105
92 75
Height
95 mm
75
105
112
92
4-5.5 × 8
For M5
with ring terminal Length of lead wire
4 slots for M5 Length of lead wire: 140 mm 140 mm
PM-SDL03/PM-SDL04 Height: 91 mm V5.5-5
PM-SDL05 PM-SDL06
133 97
90 82
MAX 150
Height
100
80
64
MAX Height
180 mm 86 mm
Noise Filter
OUT
L1 L4
L1 L2 L3 PE
80
90
L2 L5
70
90
S R T
L3 L6
M5 screw
M5 screws
66
Height: 54 mm M4 screw for 2-φ4.5
150 5 2-4.5 × 6 slot grounding
PM-SNF03 PM-SNF07 Height: 55 mm
L1 L1'
LOAD
FN3011-75-62
LINE
70
IN
L2 L2'
OUT
L1 L1'
100
1
L3 L3'
85
4
44
65
2 L2 L2'
5
3 6
L3 L3'
M4 screw 177
196
2-φ5.5 × 7 2-φ5.5 214 Height 4-φ5.3 × 6.5
M5 × 6 (slot)
84 mm
Height: 140 mm Height: 85 mm
Regenerative Resistance
PM-RB02
RBP2-4
Ring Core
PM-SRC01 PM-SRC02
17 47
φ20.6
φ49
φ24
φ40
49
High Pressure/High Flow Rate/Analog Command Input/High-accuracy Type
SUPER UNIT
Ferrite Core
PM-FC01 PM-FC04 PM-FC05
41
47
φ10.5
26.6 34
φ31.7
φ20.6
φ14
φ40
25.4
PM-FC01
Regenerative brake unit SB-PP03158-03 Regenerative resistance SB-PP03159-05 Ferrite core SB-PP02137-02
4-φ5.5 holes (for fixing bolts) 4-φ6 holes (for fixing bolts) 41
(M5 bolts recommended) (M5 bolts recommended)
341
125
291
φ20.6
80
φ14
Height: H = 171
Height: H = 140
Ring core SB-PP0404-02
248
260
618
638
TA TB TC
21
Terminal block,
M6 screw
DB P+ P+ N-
φ75.7
φ44.2
Th1 R1 Th2 R2 □E
50
High Pressure High Flow Rate
Analog Command Input High Accuracy
SUPER UNIT
HYBRID HYDRAULIC UNIT
Osaka Office
YODOGAWA PLANT
1-1, Nishi-Hitotsuya, Settsu, Osaka 566-8585, Japan
Phone: 81-6-6349-4475
Fax.: 81-6-6349-7862
Home Page: http://www.daikinpmc.com/en/
Contents in this catalog are subject to change for improvement without prior notice.
GK250(2016.12.010)DF.MD.MD