For Meralco
For Meralco
1. ALL ELECTRICAL WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THE PROVISION OF THE
PB SCHEDULE OF LOADS : 100AT/125AF, MCCB, 22KAIC, 2PST, 230V, 60HZ, BOLT-ON TYPE IN NEMA 3R ENCLOSURE
LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, TO THE RULES AND REGULATIONS OF
CIRCUIT NO. OF LOAD CB RATING
AND NATIONAL AUTHORITIES AND THE REQUIREMENTS OF LOCAL UTILITY COMPANY
CONCERNED.
LOCAL
NO.
1
LOAD DESCRIPTION
700
VOLTS
230
AMPERE
3.04
AT
20
AF
50
POLE
2
KAIC
10
SIZE OF WIRE AND CONDUIT
2-3.5MM² THHN WIRE + 1-3.5MM² TW WIRE (G) IN 20MMØ UPVC PIPE SERVICE ENTRANCE
USE: 2-30MM² THHN WIRE +
1-8.0MM² TW WIRE (G) SINGLE LINE DIAGRAM
2. ALL WIRING INSTALLATIONS SHALL BE CONCEALED FROM VIEW AND INSTALLING THE 230V, 2-WIRES + G, 2-POLE IN 32MMØ IMC PIPE
CONDUCTORS IN UNPLASTICISED POLYVINYL CHLORIDE (UPVC PNS14) ELECTRICAL CONDUIT AND 2 CONVENIENCE OUTLET, 2-GANG 05 1000 230 3.58 20 50 2 10 2-3.5MM² THHN WIRE + 1-3.5MM² TW WIRE (G) IN 20MMØ UPVC PIPE
INTERMEDIATE METALLIC CONDUIT (IMC SCHEDULE 40) WHEN USED AS SERVICE ENTRANCE. KWH METER, DIGITAL TYPE
3 CONVENIENCE OUTLET, 2-GANG 04 720 230 6.08 20 50 2 10 2-3.5MM² THHN WIRE + 1-3.5MM² TW WIRE (G) IN 20MMØ UPVC PIPE
CONCRETE M 230V, 60HZ, 2-POLE POWER SERVICE ENTRANCE
3. UNLESS OTHERWISE SPECIFIED, MINIMUM SIZE OF WIRE & CONDUIT SHALL BE 3.5MM² THHN/THWN 4 CONVENIENCE OUTLET, 2-GANG 01 3500 230 4.34 20 50 2 10 2-3.5MM² THHN WIRE + 1-3.5MM² TW WIRE (G) IN 20MMØ UPVC PIPE
PEDESTAL 230V, 2-WIRES + G, 2-POLES
20MMØ UPVC PIPE RESPECTIVELY, AND MINIMUM SIZE OF WIRE IN SERVICE ENTRANCE SHALL
AND
BE 8.0MM² THHN/THWN @ 32MMØ IMC PIPE. 5 SPARE 01 750 230 3.26 20 50 2 10 2-3.5MM² THHN WIRE + 1-3.5MM² TW WIRE (G) IN 20MMØ UPVC PIPE ECB 100AT/125AF, MCCB, 22KAIC,
GROUND WIRE 2-POLE, IN NEMA 3R ENCLOSURE
6 1-8.0MM² TW WIRE
4. STANDARD TYPE OF ACCESSORIES, SPLICING DEVICES, TERMINATION AND OTHER SECOND FLOOR
APPURTENANCES FOR THE ENTIRE ELECTRICAL INSTALLATION SHALL BE USED. IN 20MMØ UPVC PIPE
7 & 3/4"Ø x 3M GROUND ROD
USE: 2-30MM² THHN WIRE +
8
5. THE FOLLOWING MOUNTING HEIGHT ARE TO BE FOLLOWED: 1-8.0MM² TW WIRE (G) USE: 2-30MM² THHN WIRE
a. CONVENIENCE OUTLET - 0.30M FROM CENTER OF OUTLET TO F.F.L. IN 32MMØ UPVC PIPE + 1-8.0MM² TW WIRE (G) CONCRETE PEDESTAL
b. WALL SWITCHES - 1.40M FROM CENTER OF DEVICE TO F.F.L. 9 IN 32MMØ IMC PIPE ( VERIFY DIMENSION )
PB
c. PANEL BOARDS - 1.80M FROM TOP OF PANELTO F.F.L. 10
d. WEATHER PROOF OUTLET - 0.30M FROM CENTER OF OUTLET TO F.F.L.
e. SERVICE ENTRANCE - 3.60M MIN & 7.50M MAX FROM TOP TO F.F.L. 11 PB
f. METER - 1.95M FROM CENTER TO F.F.L. KILOWATT-HOUR METER, 2P 100AT/125AF, 2P
12 100AT/125AF 22KAIC, MCCB
g. COUNTER TOP CONVENIENCE OUTLET - 0.30 FROM CENTER OF OUTLET TO F.F.L. ECB 100AT/125AF, 2P, 22KAIC
230V, 2P, 60HZ MCCB IN NEMA 3R ENCLOSURE
13
6. PANEL BOARDS SHALL BE PROVIDED WITH CIRCUIT DIRECTORY. MAIN CIRCUIT BREAKERS SHALL 22KAIC, MCCB
BE MOULDED CASE TYPE (PNS 519) 2-POLE, FOR BRANCH CIRCUIT BREAKERS SHALL BE BOLT-ON 14
MINIATURE TYPE. TOTAL 22,535 VA 97.97 AMPS.
1 20AT 2P 2P 20AT 2 GROUND FLOOR
7. THE SERVICE EQUIPMENT AND ALL OTHER EQUIPMENTS SHALL BE PROVIDED WITH ADEQUATE
AND PROPER INSTALLED GROUNDING. 3 30AT 2P 2P 20AT 4
TOTAL CURRENT : IT = 97.97(80%DF) + 8.00(25%) = 80.37 AMPS. USE: 2-30MM² THHN WIRE + 1-8.0MM² TW WIRE (G)
8. ALL ELECTRICAL WORKS HEREIN SHALL BE DONE UNDER THE SUPERVISION OF 5 20AT 2P 2P 20AT 6 USE: 1-8.0MM² TW WIRE IN 20MMØ UPVC PIPE
IN 32MMØ UPVC PIPE, CEMENT COVERED
DULY LICENSED ELECTRICAL ENGINEER. SUB FEEDER LINE : USE 2-30MM² THHN WIRE + 1-8.0MM² TW WIRE (G) IN 32MMØ UPVC PIPE & 3/4"Ø x 3M GROUND ROD COPPER WELD
7 20AT 2P 2P 20AT 8
MAIN CIRCUIT BREAKER : 100AT/125AF, MCCB, 22KAIC, 2PST, 230V, BOLT-ON TYPE IN NEMA 3R ENCLOSURE
9 20AT 2P 2P 15AT 10
11 15AT 2P 2P 15AT 12
13 15AT 2P 2P 15AT 14
THIS SITE
GROUND BUSBAR
GROUND WIRE
1-8.0MM² TW WIRE
LEGEND SERVICE ENTRANCE
TELEPHONE & WIFI
SATELLITE DISK
FACING SOUTH-WEST
LED PANEL LIGHT, 5"Ø, RECESS. TYPE TELEPHONE & WIFI ROUTER WP WEATHER PROOF 2-GANG OUTLET CABLE TV / TELEPHONE & WIFI BOX CABLE TV OUTLET
LED PENDANT LIGHT ROUND S1 SINGLE GANG SWITCH WIDE TYPE SATELLITE CABLE DISK
FCU
FAN COIL UNIT, WALL MOUNTED
LED PANEL LIGHT, 2"Ø, RECESS. TYPE S12 TWO GANG SWITCH WIDE TYPE CIRCUIT BREAKER, 2P, BOLT-ON TYPE CB
ACCU AIR COOLED CONDENSING UNIT W/ NEMA 3R
COAXIAL CABLE WIRE RG6
IN 20MMØ UPVC PIPE, EACH LINE
CABLEBOX
TV
LED CHANDELIER, SUSPENDED TYPE S123 THREE GANG SWITCH WIDE TYPE WP WEATHER PROOF 2-GANG OUTLET CABLE TV OUTLET TERMINAL
TEL & WIFI
BOX CABLE TV OUTLET TEL
ROUTER
& WIFI
LED CIRCULAR LIGHT, SURFACED TYPE LED STRIP LIGHT, RGB TYPE
D
S 3W THREE WAY SWITCH + 1-GANG SWITCH S 3W THREE WAY SWITCH
UTILITY BOX
UPVC GROUND FLOOR
CONV. 2-GANG OUTLET, 3-UNIV. PRONG SERVICE ENTRANCE, ON CONCRETE PEDESTAL LED PENDANT LIGHT SQUARE EXHAUST FAN CEILING TYPE
2
C C C
10
PB C C
PB
h g j j
C
3S3S l
h i g
C C C
3 C
C C
1
C
PB k k
PB 3Sjkl 11 PB
3Sghi
C
C C
h g
C C
3S
3-WAY S
17 3 17
17 17
16
16 16 PB 16
C 15 15
C C C
15 C d d d 15
14 14
14 14
12 13
13 13
13
12
12 12
PB 12
11 11
11 11
10
10
2 10
10
9
9
C
C PB C 9
9
C e f e
8 8
8 8
C C 7
7 7 7
6 6 6 6
2Sef
2Scd 5
5 5 5
1HP BOOSTER
PUMP c c c
C
UP 4 UP
C C
C
1 2 3 4 PB 1 2 3 4
S 2Sab
2S
3S
C
C C
a a
C 4
3S PB
3S s
1
S C C C
PB b b
C
DESIGN CONSULTANT:
IMPORTANT: PROJECT: SHEET NO:
THESE DRAWINGS ARE
INTELLECTUAL PROPRIETARY
JOHN ROBERT CHIU CHUA
E
RIGHTS RETAINED BY
DESIGNER OVER ANY
DESIGNERS DOCUMENTS O W N E R
PROFESSIONAL ELECTRICAL ENGINEER
UNLESS THERE IS A
WRITTEN STIPULATION TO AS BUILT TWO STOREY RESIDENTIAL
THE
PTR NO. REG. NO.: CONTRARY, COPYRIGHT IN A
WORK OF DESIGNER. SHEET CONTENTS: AS SHOWN
VALIDITY: TIN:
LOCATION: 157 F BIAK N BATO ST. STA. MESA HEIGHTS, QUEZON
PLACE: DATE: 544)
CITY
DESIGN DEVELOPMENT FOR PERMIT PLAN FOR CONSTRUCTION PLAN ADDENDUM PLAN AS-BUILT PLAN