Variable speed drives Altivar 71

Catalog March

05
PRELIMINARY GLOBAL CATALOG Refer to Statement of Scope on page 2.

For 3-phase asynchronous motors from 0.5 to 700 hp (0.37 to 500 kW)

Statement of Scope This is Schneider Electrics global catalog for the Altivar 71 variable speed drives. It should be used as the preliminary catalog in North America until the North American version is released with the product launch in June, 2005. It can be retained and used thereafter as a source of information about equipment that ships to North America from other countries. The following accessories described in this catalog are not stocked in our North American warehouse because they do not all adhere to applicable codes: b b b b b b b b b Braking resistors Hoisting resistors Network braking units DC chokes Line chokes Passive filters EMC filters Output filters Sinusoidal filters

Please refer to the AC Drives and Soft Starts Pricing Guide, 8800PL9701R5/04, for alternate versions of these accessories that are suited for the North American market. Note that the circuit breaker information provided in this catalog refers to IEC devices that may not comply with the UL 489 definition of a circuit breaker. As such, they should only be used to build equipment for export. The North American version of the Altivar 71 catalog will include a list of tested combinations that comply with the new NEC Article 409 and UL 508 requirements.

Contents

Variable speed drives for asynchronous motors Altivar 71


b Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4 b Presentation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6 b Variable speed drives v Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10 v Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16 v Catalog numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 20 b Options v accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22 v dialogue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 28 v encoder interface cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 30 v I/O extension cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 32 v "Controller Inside" programmable card . . . . . . . . . . . . . . . . . . . . . . . . . page 34 v communication buses and networks . . . . . . . . . . . . . . . . . . . . . . . . . . . page 42 v resistance braking units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 50 v braking resistors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 52 v hoist resistors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 54 v network braking units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 64 b Reduction of current harmonics v DC chokes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 68 v line chokes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 72 v passive filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 75 v additional EMC input filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 78 v output filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 82 v motor chokes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 83 v sinusoidal filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 85 b Combinations of variable speed drives and options . . . . . . . . . . . . . . page 88 b Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 92 b Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 114 b Motor starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 130 b Mounting recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 134 b Combinations of functions and applications . . . . . . . . . . . . . . . . . . . page 142 b Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 144 b Compatibilty table for functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 176 b PowerSuite software workshop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 178 b Ethernet TCP/IP network. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 182 b Communication via Fipio bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 188 b Communication via Modbus bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 192 b Communication via Modbus Plus bus. . . . . . . . . . . . . . . . . . . . . . . . . page 196 b Communication via Uni-Telway bus . . . . . . . . . . . . . . . . . . . . . . . . . . page 200 b Communication gateways LUF P. . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 202 b Communication gateway LA9 P307 . . . . . . . . . . . . . . . . . . . . . . . . . . . page 204

Global Catalog. Refer to Statement of Scope on page 2.

Selection guide

Variable speed drives for asynchronous motors

Applications Application area Type of machine

Variable speed control for AC motors Industry Simple machines

Power range for 5060 Hz supply hp (kW) Single phase 100120 V hp (kW) Single phase 200240 V hp (kW) Three phase 200230 V hp (kW) Three phase 200240 V hp (kW) Three phase 380460 V hp (kW) Three phase 380480 V hp (kW) Three phase 380500 V hp (kW) Three phase 525600 V hp (kW) Drive Output frequency Type of control Asynchronous motor Synchronous motor Transient overtorque

0.25 to 3 (0.182.2) 0.25 to 1 (0.180.75) 0.25 to 3 (0.182.2) 0.25 to 3 (0.182.2) 0.5200 Hz Sensorless flux vector control 150170% of the nominal motor torque

0.25 to 20 (0.1815) 0.25 to 3 (0.182.2) 0.25 to 20 (0.1815) 0.5 to 20 (0.3715) 1 to 20 (0.7515) 0.5500 Hz

170200% of the nominal motor torque

Functions Number of functions Number of preset speeds Number of I/O Analog inputs Logic inputs Analog outputs Logic outputs Relay outputs Communication Embedded Available with gateways

26 4 1 4 1 1

50 16 3 6 1 2 Modbus and CANopen Ethernet TCP/IP, DeviceNet, Fipio, Profibus DP

Cards (available as an option)

Standards and certification

EN 50178, IEC/EN 61800-3 EN 55011, EN 55022: class B and class A gr.1 e, UL, CSA, NOM 117, C-Tick

EN 50178, IEC/EN 61800-3 EN 55011, EN 55022: class A, class B with option card e, UL, C-Tick, N998

Catalog numbers

ATV 11

ATV 31

Pages

Please consult Automation and Control: The Essential Guide, catalog no. 0140CT0401

Global Catalog. Refer to Statement of Scope on page 2.

Building Pumps and fans

Industry Complex, modular machines Machines requiring high-performance, torque regulation, dynamic speed regulation, and accuracy at very low speeds High-power machines

0.5 to 500 (0.75315) 0.5 to 500 (0.75315) 0.1500 Hz Sensorless flux vector control 110% of nominal motor torque for 60 seconds

0.5 to 700 (0.37500) 0.5 to 7.5 (0.375.5) 0.5 to 100 (0.3775) 1 to 700 (0.75500) 01000 Hz Flux vector control with or without sensor, voltage/frequency ratio (2 or 5 points), unbalanced loads Vector control without speed feedback 220% of nominal motor torque for 2 seconds, 170% for 60 seconds

44 8 23 46 12 01 2 Modbus Ethernet TCP/IP, Fipio, Modbus Plus, INTERBUS, Profibus DP, AS-Interface, Uni-Telway, CANopen, DeviceNet, METASYS N2, Lonworks Pump switching I/O extension cards Programmable "Controller Inside" card EN 50178, IEC/EN 61800-3 EN 55011 class A EN 55022 class B e, UL, N998

> 150 16 24 620 13 08 24 Modbus and CANopen Ethernet TCP/IP, Fipio, Modbus Plus, INTERBUS, Profibus DP, Modbus/Uni-Telway, DeviceNet

Encoder interface cards I/O extension cards Programmable "Controller Inside" card

IEC/EN 61800-5-1, IEC/EN 61800-3 (environments 1 and 2, C1 to C3) EN 55011, EN 55022, IEC/EN 61000-4-2/4-3/4-4/4-5/4-6/4-11 e, UL, CSA, DNV, C-Tick, NOM 117, GOST

ATV 58

ATV 71

Consult Automation and Control: The Essential Guide, no. 0140CT0401

see pages 20 and 21

Global Catalog. Refer to Statement of Scope on page 2.

Presentation

Variable speed drives for asynchronous motors


Altivar 71

Applications
The Altivar 71 range of variable speed drives is able to respond to the most exacting requirements thanks to its different types of motor control and numerous onboard functions. It is suitable for the most demanding drives: b Torque and speed accuracy at very low speeds, high dynamics with Flux Vector Control (with or without sensor) b Extended frequency range for high-speed motors b Connection of special motors and drives in parallel thanks to the voltage/frequency ratio b Static speed accuracy and energy savings for synchronous motors in open loop mode b Smooth flexibility for unbalanced machines with the ENA System (Energy Adaptation System) The functionality of the Altivar 71 drive boosts performance and increases a machines flexibility of use across multiple applications.
Hoisting application
532537

Hoisting b Brake control adapted for translational, hoisting and slewing movements b Load measurement using weight sensor b High-speed hoisting b Brake feedback management b Limit switch management Handling b Very quick response times on transmission of a command: 2 ms ( 0.5 ms) b Reference via pulse train or differential analog input b Control via the principal communication networks b Position control via limit switches with time optimization at low speed b Multiple parameter-settings via parameter set switching Packing b Up to 50 Hz of the bandwidth b Very quick response times on change of reference: 2 ms ( 0.5 ms) b Control via integrated CANopen bus b Position control via limit switches Textile machinery b High resolution of the digital speed reference (1/32000) b Speed accuracy assured by use of synchronous motor, irrespective of the load b High bandwidth b Spooling function b Connection to common DC bus Wood-working machinery b Operation up to 1000 Hz b Fastest possible controlled stop on loss of line supply b Control via integrated CANopen bus b Protection of motor against overvoltages Process machinery b PID regulator b High reference resolution b Speed or torque control b Connection to the principal communication networks b Separate control power supply b Braking unit via re-injection to the line supply b Connection to common DC bus Lifts b Brake control adapted to suit passenger comfort b Processing of load measurement by weight sensor b Conformity of relays to lift safety standard EN 81-13-2-2-3 b Connection to CANopen bus b Control with integrity check of output contactor b Lift car clearance function

532538

Packing application

532539

Process machinery application

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

Presentation (continued)

Variable speed drives for asynchronous motors


Altivar 71

532726

Comprehensive offer
The Altivar 71 range of variable speed drives extends across a range of motor power ratings from 0.37 kW to 500 kW with three types of power supply: b 200 240 V single phase, from 0.5 to 7.5 hp (0.37 to 5.5 kW) b 200 240 V three phase, from 0.5 to 100 hp (0.37 to 75 kW) b 380 480 V three phase, from 1.0 to 700 hp (0.75 to 500 kW) The Altivar 71 drive integrates the Modbus and CANopen protocols as standard as well as numerous functions. These functions can be extended using communication, I/O and encoder interface option cards (see page 9). The entire range conforms to international standards IEC/EN 61800-5-1, IEC/EN 61800-2, IEC/EN 61800-3, is e, UL, CSA, DNV, C-Tick, NOM 117 and GOST certified and has been developed to meet the directives regarding protection of the environment (RoHS, WEEE, etc). The Altivar 71 can be inserted in an installations safety system. It integrates the Power Removal safety function which prohibits any accidental starting of the motor. This function complies with machine standard EN 954-1 category 3, the standard governing electrical installations IEC/EN 61508 SIL2 and the power drive systems standard IEC/EN 61800-5-2. Electromagnetic compatibility EMC The incorporation of EMC filters in ATV 71HpppM3 and ATV 71HpppN4 drives and the recognition of EMC requirements simplifies machine installation and provides an economical means of meeting e marking requirements. ATV 71HpppM3X drives are available without EMC filters. The filters are available as an option and can be installed by the user to reduce emission levels (see pages 78 to 81). Other external options, such as braking resistors, network braking units and filters, are available to complement this offer (see page 9).

ATV 71HC28N4, ATV 71HD37M3X, ATV 71HU22N4

533235

Installation
The Altivar 71 drive has been designed to optimize the size of enclosures (floor-standing, wall-mounted, etc): b The power part, with IP 54 degree of protection, can be easily mounted outside the enclosure using the kit for flush-mounting in a dust and damp proof enclosure VW3 A9 5pp. This type of mounting can be used to limit the temperature rise inside the enclosure or to reduce the size of enclosure required (see page 7). b Ambient temperature inside the enclosure: v 50C without derating v Up to 60C using the control card fan kit VW3 A9 4pp corresponding to the drive rating and, if necessary, by derating the output current (see page 22) b Mounting side-by-side (see pages 134 and 136) The drive can also be wall-mounted in compliance with NEMA type 1 requirements using kit VW3 A9 2pp, for IP 21 protection or IP 31 using kit VW3 A9 1pp (see pages 24 and 25).
ATV 71HU75N4 flush-mounted

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

Presentation (continued)

Variable speed drives for asynchronous motors


Altivar 71

Dialogue tools
2 The Altivar 71 drive 1 is supplied with a removable graphic display terminal 2 for remote operation: b The navigation button accesses the drop-down menus quickly and easily. b The graphic screen displays 8 lines of 24 characters of plain text. b The advanced functions on the display unit access the more complex drive functions. b The display screens, menus and parameters can all be customized for the user or the machine. b Online help screens are available. b Configurations can be stored and downloaded (four configuration files can be stored). b The drive can be connected to several other drives via a multidrop link. b It can be located remotely on an enclosure door with IP 54 or IP 65 degree of protection. b It is supplied with 6 languages installed as standard (English, French, German, Italian, Spanish and Chinese). Other languages can be loaded to the flash memory. Up to 120 hp (15 kW), the Altivar 71 drive can be controlled using an integrated 7-segment display terminal (see pages 20 and 21). The PowerSuite software workshop 3 can be used to configure, adjust and debug the Altivar 71 in just the same way as all other Telemecanique drives and starters. It can be used via a direct connection, Ethernet, modem or a Bluetooth wireless connection.

1 3

Quick programming
522151

RUN

Term
:

+50.00Hz

5.4A
2 wire

1.1 SIMPLY START 2/3 wire control Macro-configuration : Standard mot. Freq. : Rated motor power : Rated motor volt. : M. handling 50Hz IEC 2.2kW 400V

Macro-configuration The Altivar 71 offers quick and easy programming using macro-configurations corresponding to different applications or uses: start-stop, material handling, hoisting, general use, connection to communication networks, PID regulator, master/slave. Each of these configurations is still fully modifiable. Simply start menu The Simply start menu can be used to ensure the application operates correctly, obtain maximum motor performance and ensure motor protection. The architecture, the hierarchical parameter structure and the direct access functions all serve to make programming quick and easy, even for the more complex functions.

Code

<<

>>

Quick

Simply start menu

Services
SCF1 Term +50.00Hz 0.0A
FAULT HISTORY Short circuit Overcurrent External FLT Overvoltage Undervoltage

Help
Fault log
522162

Quick

SCF1

Term

+50.00Hz

0.0A

MOTOR SHORT CIRCUIT Check the connection cables and the motor insulation. Perform the diagnostic test.

The Altivar 71 has numerous built-in maintenance, monitoring and diagnostic functions: b Built-in drive test functions with diagnostic screen on the remote graphic display terminal b I/O maps b Communication maps for the different ports b Oscilloscope function that can be viewed using the PowerSuite software workshop b Management of the drive installed base via processors with flash memory. b Remote use of these functions by connecting the drive to a modem via the Modbus port b Identification of all the drives component parts as well as the software versions b Fault logs with display of the value of up to 16 variables on occurrence of a fault b Display terminal languages loaded in the flash memory b A message of up to 5 lines of 24 characters can be stored in the drive.

533523

Quick
Troubleshooting screen

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

Presentation (continued)

Variable speed drives for asynchronous motors


Altivar 71

Options
The Altivar 71 drive 1 can integrate a maximum of three option cards simultaneously, of which: b 2 can be selected from among the following (1): v I/O extension cards 2 (see pages 32 and 33) v communication cards 2 (Ethernet TCP/IP, Modbus/Uni-Telway, Fipio, Modbus Plus, Profibus DP, DeviceNet, INTERBUS, etc) (see pages 42 to 49) v programmable Controller Inside card 2. This is used to adapt the drive to specific applications quickly and progressively, by decentralizing the control system functions (programming in IEC 61131-3 compliant languages) (see pages 34 to 41). b 1 can be an encoder interface card 3 (with RS 422 compatible differential outputs, open collector outputs, push-pull outputs) (see pages 30 and 31). External options can be associated with the Altivar 71: b Braking units and resistors (standard or hoist-specific) (see pages 50 to 63) b Networked braking units (see pages 64 to 67) b Line chokes, DC chokes and passive filters, to reduce harmonic currents (see pages 68 to 77) b Motor chokes and sinusoidal filters for long cable runs or to remove the need for shielding (see pages 82 to 87) b Additional EMC input filters (see pages 78 to 81)
Note: please refer to the compatibility summary tables to determine which options are available for individual drives (see pages 88 to 91).

Integration into control systems


Premium ATV 71 Magelis XBT

The Altivar 71 integrates a combined Modbus or CANopen port for quick, accurate motion control, adjustment, supervision and configuration. A second port is available for connecting a Magelis terminal for machine dialogue. The drive can also be connected to other communication networks using the communication option cards (see pages 42 to 49).

Ethernet CANopen master

Modbus

The control part can be powered separately, thus allowing communication (monitoring, diagnostics) to be maintained even if the power part supply fails. The programmable Controller Inside card transforms the drive into an automation island: b The card integrates its own I/O; it can also manage those of the drive and an I/O extension card. b It contains onboard application programs developed in IEC 61131-3 compliant languages, which reduce the control system response time. b Its CANopen master port enables control of other drives and dialogue with I/O modules and sensors.
(1) The Altivar 71 cannot support more than one option card with the same catalog number. Please refer to the compatibility tables summarizing the possible combinations for drives, options and accessories on pages 88 to 195.

I/O STB ATV 31

I/O OTB

Sensor

Example of a drive equipped with a communication card and a programmable Controller Inside card

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

Characteristics

Variable speed drives for asynchronous motors


Altivar 71

Environmental characteristics
Conformity to standards Altivar 71 drives have been developed to conform to the strictest international standards and the recommendations relating to electrical industrial control devices (IEC, EN), in particular: low voltage, IEC/EN 61800-5-1, IEC/EN 61800-3 (conducted and radiated EMC immunity and emissions). IEC/EN 61800-3, environments 1 and 2 IEC/EN 61000-4-2 level 3 IEC/EN 61000-4-3 level 3 IEC/EN 61000-4-4 level 4 IEC/EN 61000-4-5 level 3 IEC/EN 61000-4-6 level 3 IEC/EN 61000-4-11 (1) IEC/EN 61800-3, environments 1 and 2, categories C1, C2, C3 EN 55011 class A group 1, IEC/EN 61800-3 category C2 With additional EMC filter (2): b EN 55011 class B group 1, IEC/EN 61800-3 category C1 EN 55011 class A group 2, IEC/EN 61800-3 category C3 With additional EMC filter (2): b EN 55011 class A group 1, IEC/EN 61800-3 category C2 b EN 55011 class B group 1, IEC/EN 61800-3 category C1 With additional EMC filter (2): b EN 55011 class A group 1, IEC/EN 61800-3 category C2 b EN 55011 class B group 1, IEC/EN 61800-3 category C1 The drives are marked e in accordance with the European low voltage (73/23/EEC and 93/68/EEC) and EMC (89/336/EEC) directives. UL, CSA, DNV, C-Tick, NOM 117 and GOST IEC/EN 61800-5-1, IEC/EN 60529 IP 21 and IP 41 on upper part IP 20 without cover plate on upper part of cover IP 21 with accessory VW3 A9 1pp, NEMA type 1 with accessory VW3 A9 2pp, see pages 24 and 25 IP 00, IP 41 on the upper part and IP 30 on the front panel and side parts. IP 31 with accessory VW3 A9 1pp, NEMA type 1 with accessory VW3 A9 2pp, see pages 24 and 25 1.5 mm peak to peak from 313 Hz, 1 gn from 13200 Hz, conforming to IEC/EN 60068-2-6 1.5 mm peak to peak from 310 Hz, 0.6 gn from 10200 Hz, conforming to IEC/EN 60068-2-6 15 gn for 11 ms conforming to IEC/EN 60068-2-27

EMC immunity

Conducted and radiated EMC emissions for drives

ATV 71H037M3HU15M3 ATV 71H075N4HU40N4 ATV 71HU22M3HU75M3 ATV 71HU55N4HC50N4

ATV 71HpppM3X

e marking Product certifications Degree of protection ATV 71HpppM3 ATV 71HD11M3XHD45M3X ATV 71H075N4HD75N4 ATV 71HD55M3X, HD75M3X ATV 71HD90N4HC50N4 Vibration resistance ATV 71HpppM3 ATV 71HD11M3XHD45M3X ATV 71H075N4HD75N4 ATV 71HD55M3X, HD75M3X ATV 71HD90N4HC50N4 ATV 71HpppM3 ATV 71HD11M3XHD45M3X ATV 71H075N4HD75N4 ATV 71HD55M3X, HD75M3X ATV 71HD90N4HC13N4 ATV 71HC16N4HC50N4 ATV 71HpppM3 ATV 71HD11M3X, HD15M3X ATV 71H075N4HD18N4 ATV 71HD18M3XHD75M3X ATV 71HD22N4HC50N4 ATV 71HpppM3, HpppM3X, ATV 71HpppN4 ATV 71HpppM3S337, ATV 71HpppM3X337, ATV 71H075N4S337 HD75N4S337, ATV 71HD90N4HC50N4 Operation C

Shock resistance

7 gn for 11 ms conforming to IEC/EN 60068-2-27 4 gn for 11 ms conforming to IEC/EN 60068-2-27 Degree 2 conforming to IEC/EN 61800-5-1

Maximum ambient pollution

Degree 3 conforming to IEC/EN 61800-5-1 IEC 60721-3-3 classes 3C1 and 3S2 IEC 60721-3-3 class 3C2

Environmental conditions

Relative humidity Ambient air temperature around the device

Storage Maximum operating altitude

C m

595% without condensation or dripping water conforming to IEC 60068-2-3 - 10+ 50 without derating Up to 60C with derating and with the control card fan kit VW3 A9 4pp corresponding to the drive rating (see derating curves on pages 135 and 137 to 139) - 25+ 70 1000 without derating 10003000 derating the current by 1% per additional 100 m. Limited to 2000 m for the Corner Grounded distribution network
10 10

Operating position Maximum permanent angle in relation to the normal vertical mounting position

(1) Drive behaviour according to the drive configurations (see pages 161, 164, 165, 173 and 174). (2) See table on page 78 to check permitted cable lengths.

Presentation: pages 6 to 8

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

10

Global Catalog. Refer to Statement of Scope on page 2.

Characteristics (continued)

Variable speed drives for asynchronous motors


Altivar 71

Drive characteristics
Output frequency range ATV 71HpppM3 ATV 71HD11M3XHD37M3X ATV 71H075N4HD37N4 ATV 71HD45M3XHD75M3X ATV 71HD45N4HC50N4 ATV 71HpppM3 ATV 71HD11M3X, HD15M3X ATV 71H075N4HD30N4 ATV 71HD18M3XHD75M3X ATV 71HD37N4HC50N4 Hz 101000

Hz kHz kHz

10500 Adjustable during operation from 18, 2.58 or from 116 according to rating 4 without derating in continuous operation Above this frequency, see derating curves on pages 135 and 137 to 139 2.5 without derating in continuous operation. Above this frequency, see derating curves on pages 135 and 137 to 139 11000 in closed loop mode with encoder feedback 1100 in open loop mode 0.01% of nominal speed, in closed loop mode with incremental encoder feedback 10% of nominal slip, without speed feedback 5% in closed loop mode 15% in open loop mode 170% of the nominal motor torque (typical value at 10%) for 60 s 220% of the nominal motor torque (typical value at 10%) for 2 s 30% of motor nominal torque without braking resistor (typical value) Up to 150% with optional braking resistor, see pages 53 and 55 150% of the nominal drive current for 60 s (typical value) 165% of the nominal drive current for 2 s (typical value) The Altivar 71 drive can continuously supply the peak value of the drive nominal current The Altivar 71 drive can continuously supply 80% of the peak value of the drive nominal current Flux Vector Control (FVC) with sensor (current vector) Sensorless Flux Vector Control (FVC) (voltage or current vector) Voltage/frequency ratio (2 or 5 points) ENA (Energy Adaptation) System for unbalanced loads Vector control without speed feedback PI regulator with adjustable structure for a speed response adapted to the machine (accuracy, speed) Automatic whatever the load. Can be suppressed or adjusted Not available in voltage/frequency ratio 200 - 15%...240 + 10% single phase for ATV 71H075M3...HU75M3 200 - 15%...240 + 10% 3-phase for ATV 71HpppM3 and ATV 71HpppM3X 380 - 15%...480 + 10% 3-phase for ATV 71HpppN4 50 - 5%...60 + 5% 1 red LED: LED lit indicates the presence of drive voltage Maximum 3-phase voltage equal to line supply voltage Conforming to directive 86-188/EEC 43 54.5 55.6 57.4 60.2 59.9 64 63.7 60.5 69.5 66 68 70 71 Between power and control (inputs, outputs, power supplies)

Configurable switching frequency

kHz

Speed range Speed accuracy Torque accuracy Transient overtorque Braking torque Maximum transient current Continuous torque at 0 Hz ATV 71H037M3HD45M3X ATV 71H075N4HD75N4 ATV 71HD55M3X, HD75M3X ATV 71HD90N4HC50N4 Asynchronous motor For a torque variation of 0.2 Tn to Tn

Motor control profile

Synchronous motor Frequency loop Slip compensation

Electrical power characteristics


Power supply Voltage V

Frequency Signalling Output voltage Drive noise level ATV 71H037M3HU15M3 ATV 71H075N4HU22N4 ATV 71HU22M3HU40M3 ATV 71H075N4HU40N4 ATV 71HU55M3 ATV 71HU55N4, HU75N4 ATV 71HU75M3 ATV 71HD11N4 ATV 71HD11M3X, HD15M3X ATV 71HD15N4, HD18N4 ATV 71HD18M3X, HD22M3X ATV 71HD22N4 ATV 71HD30M3XHD45M3X, ATV 71HD30N4, HD37N4 ATV 71HD45N4HD75N4 ATV 71HD55M3X ATV 71HD90N4 ATV 71HD75M3X ATV 71HC11N4 ATV 71HC13N4, HC16N4 ATV 71HC20N4HC28N4 ATV 71HC31N4, HC40N4 ATV 71HC50N4 Electrical isolation

Hz

dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA

Presentation: pages 6 to 8

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages114 to 129

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

11

Characteristics (continued)

Variable speed drives for asynchronous motors


Altivar 71

Connection cable characteristics


Type of cable for Mounting in an enclosure Mounting in an enclosure with an IP 21 or IP 31 kit Mounting in an enclosure with NEMA type 1 kit Drive terminals Maximum connection capacity ATV 71H037M3HU40M3 and tightening torque ATV 71H075N4HU40N4 ATV 71HU55M3 ATV 71HU55N4, HU75N4 ATV 71HU75M3 ATV 71HD11N4 ATV 71HD11M3X, HD15M3X ATV 71HD15N4, HD18N4 ATV 71HD18M3X, HD22M3X ATV 71HD22N4 ATV 71HD30N4, HD37N4 ATV 71HD30M3X ATV 71HD37M3X ATV 71HD45M3X ATV 71HD45N4 ATV 71HD55N4 ATV 71HD75N4 ATV 71HD55M3X ATV 71HD75M3X ATV 71HD90N4 ATV 71HC11N4 ATV 71HC13N4 ATV 71HC16N4 ATV 71HC20N4 ATV 71HC25N4 Motor P 220 kW Motor P 250 kW ATV 71HC28N4 ATV 71HC31N4 ATV 71HC40N4 Motor P 350 kW Motor P 400 kW ATV 71HC50N4 Single-strand IEC cable, ambient temperature 45C, copper 90C XLPE/EPR or copper 70C PVC 3-strand IEC cable, ambient temperature 40C, copper 70C PVC 3-strand UL 508 cable except for choke (2-strand UL 508 cable), ambient temperature 40C, copper 75C PVC L1/R, L2/S, L3/T 5 mm2, AWG 10 1.3 Nm 8 mm2, AWG 8 1.3 Nm 20 mm2, AWG 4 2.5 Nm 25 mm2, AWG 3 4.4 Nm 4 x 35 mm2, 3 x AWG 2 2.5 Nm 4 x 50 mm2, 3 x AWG 1/0 2.5 Nm 4 x 70 mm2, 3 x AWG 2/0 2.5 Nm 4 x 95 mm2, 3 x AWG 4/0 2.5 Nm 4 x 120 mm2, 3 x 250 kcmil 2.5 Nm 4 x 70 mm2, 3 x AWG 2/0 2.5 Nm 4 x 95 mm2, 3 x AWG 4/0 2.5 Nm 4 x 120 mm2, 3 x 250 kcmil 2.5 Nm 2 x (3 x 95 mm2), 2 x AWG 3/0 2 x (3 x 95 mm2), 2 x AWG 3/0 2 x (3 x 70 mm2), 2 x AWG 1/0 2 x (3 x 95 mm2), 2 x AWG 3/0 2 x (3 x 95 mm2), 2 x AWG 3/0 2 x (3 x 120 mm2), 2 x AWG 4/0 2 x (3 x 185 mm2), 2 x 300 MCM 2 x (3 x 185 mm2), 2 x 350 MCM 3 x (3 x 150 mm2), 3 x 300 MCM 3 x (3 x 150 mm2), 3 x 300 MCM 3 x (3 x 185 mm2), 3 x 350 MCM 2 x 2 x (3 x 150 mm2), 2 x 2 x 300 MCM 2 x 2 x (3 x 185 mm2), 2 x 2 x 300 MCM 2 x 3 x (3 x 150 mm2), 2 x 3 x 300 MCM U/T1, V/T2, W/T3 PC/-, PO, PA/+

Connection characteristics (terminals for the power supply, the motor, and the DC bus)

2 x (3 x 70 mm2), 2 x AWG 1/0 2 x (3 x 95 mm2), 2 x AWG 3/0 1 x (3 x 95 mm2), 2 x AWG 1/0 1 x (3 x 120 mm2), 2 x AWG 3/0 1 x (3 x 150 mm2), 2 x AWG 3/0 2 x (3 x 95 mm2), 2 x AWG 4/0 2 x (3 x 120 mm2), 2 x 300 MCM 2 x (3 x 150 mm2), 2 x 350 MCM 2 x (3 x 150 mm2), 3 x 300 MCM 2 x (3 x 185 mm2), 3 x 300 MCM 3 x (3 x 150 mm2), 3 x 350 MCM 3 x (3 x 150 mm2), 5 x 300 MCM

2 x 120 mm2, 2 x AWG 4/0 2 x 120 mm2, 2 x AWG 4/0 2 x 95 mm2, 2 x AWG 3/0 2 x 120 mm2, 2 x AWG 4/0 2 x 120 mm2, 2 x AWG 4/0 2 x 150 mm2, 2 x 300 MCM 2 x 240 mm2, 3 x 250 MCM 3 x 150 mm2, 3 x 250 MCM 4 x 150 mm2, 3 x 350 MCM 4 x 150 mm2, 3 x 350 MCM 4 x 185 mm2, 5 x 300 MCM 4 x 185 mm2, 6 x 300 MCM

3 x (3 x 185 mm2), 5 x 300 MCM 4 x 240 mm2, 2 x 3 x 350 MCM 4 x (3 x 185 mm2), 6 x 300 MCM 4 x 240 mm2, 2 x 3 x 350 MCM

Presentation: pages 6 to 8

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

12

Global Catalog. Refer to Statement of Scope on page 2.

Characteristics (continued)

Variable speed drives for asynchronous motors


Altivar 71

Electrical control characteristics


Internal supplies available Short-circuit and overload protection: b 1 x 10.5 V c 5% supply for the reference potentiometer (1 to 10 k), max. current 10 mA b 1 x 24 V c supply (min. 21 V, max. 27 V), maximum current 200 mA. 24 V c (min. 19 V, max. 30 V) Power 30 W 1 bipolar differential analog input 10 V c (maximum safe voltage 24 V) Max. sampling time: 2 ms 0.5 ms Resolution: 11 bits + 1 sign bit Accuracy: 0.6% for a temperature variation of 60C Linearity: 0.15% of the maximum value 1 software-configurable current or voltage analog input: b analog voltage input 0...10 V c, impedance 30 k (max. safe voltage 24 V) b analog current input X-Y mA by programming X and Y from 0 to 20 mA, with impedance 242 Max. sampling time: 2 ms 0.5 ms Resolution: 11 bits Accuracy: 0.6% for a temperature variation of 60C Linearity: 0.15% of the maximum value See option cards 1 analog output configurable for voltage or current: b analog voltage output 0...10 V c, minimum load impedance 470 b current analog output X-Y mA by programming X and Y from 0 to 20 mA, maximum load impedance 500 Max. sampling time: 2 ms 0.5 ms Resolution: 10 bits Accuracy: 1% for a temperature variation of 60C Linearity: 0.2% See option cards 1 relay logic output, one N/C contact and one N/O contact with common point Minimum switching capacity: 3 mA for 24 V c Maximum switching capacity: b on resistive load (cos = 1): 5 A for 250 V a or 30 V c b on inductive load (cos = 0.4 and L/R = 7 ms): 2 A for 250 V a or 30 V c Max. response time: 7 ms 0.5 ms Electrical service life: 100,000 operations 1 relay logic output, one N/O contact Minimum switching capacity: 3 mA for 24 V c Maximum switching capacity: b on resistive load (cos = 1): 5 A for 250 V a or 30 V c b on inductive load (cos = 0.4 and L/R = 7 ms): 2 A for 250 V a or 30 V c Max. response time: 7 ms 0.5 ms Electrical service life: 100,000 operations See option cards 5 programmable logic inputs, 24 V c, compatible with level 1 PLC, IEC 65A-68 standard Impedance: 3.5 k Maximum voltage: 30 V Max. sampling time: 2 ms 0.5 ms Multiple assignment makes it possible to configure several functions on one input (example: LI1 assigned to forward and preset speed 2, LI3 assigned to reverse and preset speed 3) 1 logic input, configurable by a switch as a logic input or as an input for PTC probes Logic input, characteristics identical to inputs LI1...LI5 Input for a maximum of 6 PTC probes mounted in series: b nominal value < 1.5 k b trip resistance 3 k reset value 1.8 k , b short-circuit protection < 50 State 0 if y 5 V or logic input not wired, state 1 if u 11 V State 0 if u 16 V or logic input not wired, state 1 if y 10 V See option cards 1 input for the Power Removal safety function: b Power supply: 24 V c (max. 30 V) b Impedance: 1.5 k b State 0 if < 2 V, state 1 if > 17 V 2.5 mm2 (AWG 14) 0.6 Nm (1) Please consult our catalogue Power supplies, splitter blocks and interfaces.

External + 24 V power supply (1) (not provided) Analog inputs AI1-/AI1+

AI2

Configurable voltage and current analog outputs

Other inputs AO1

Configurable relay outputs

Other outputs R1A, R1B, R1C

R2A, R2B

Logic inputs LI

Other outputs LI1...LI5

LI6

Positive logic (Source) Negative logic (Sink) Other inputs Safety input PWR

Maximum I/O connection capacity and tightening torque

Presentation: pages 6 to 8

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

13

Characteristics (continued)

Variable speed drives for asynchronous motors


Altivar 71

Electrical control characteristics (continued)


Acceleration and deceleration ramps Ramp profiles: b linear, can be adjusted separately from 0.01 to 9999 s b S, U or customized Automatic adaptation of deceleration ramp time if braking capacities exceeded, possible inhibition of this adaptation (use of braking resistor). By DC injection: b by a command on a programmable logic input b automatically as soon as the estimated output frequency drops to < 0.1 Hz, period adjustable from 0 to 60 s or continuous, current adjustable from 0 to 1.2 In (in open loop mode only). Thermal protection: b against overheating b of the power stage Protection against: b short-circuits between motor phases b input phase breaks b overcurrents between output phases and earth b overvoltages on the DC bus b a break on the control circuit b exceeding the limit speed Safety function for: b line supply overvoltage and undervoltage b input phase loss, in 3-phase Thermal protection integrated in drive via continuous calculation of I2t taking speed into account: b The motor thermal state is saved when the drive is powered down. b Function can be modified via operator dialogue terminals, depending on the type of motor (force-cooled or self-cooled). Protection against motor phase breaks Protection with PTC probes Between earth and power terminals: 2830 V c Between control and power terminals: 4230 V c Between earth and power terminals: 3535 V c Between control and power terminals: 5092 V c > 1 M (electrical isolation) 500 V c for 1 minute Hz Hz 0.1 0.024/50 Hz (11 bits)

Braking to a standstill

Main drive protection and safety features

Motor protection (see page 172)

Dielectric strength

ATV 71pppM3 ATV 71pppM3X ATV 71pppN4

Insulation resistance to earth Frequency resolution Display units Analog inputs

Operational safety characteristics


Protection Of the machine Power Removal (PWR) safety function which forces stopping and/or prevents unintended equipment operation, conforming to EN 954-1 category 3 and draft standard IEC/EN 61800-5-2. Power Removal (PWR) safety function which forces stopping and/or prevents unintended equipment operation, conforming to IEC/EN 61508 level SIL2 and draft standard IEC/EN 61800-5-2.

Of the system process

Presentation: pages 6 to 8

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

14

Global Catalog. Refer to Statement of Scope on page 2.

Characteristics (continued)

Variable speed drives for asynchronous motors


Altivar 71

Communication port characteristics


Modbus protocol
Type of connection Structure Physical interface Transmission mode Transmission speed Modbus RJ45 connector port 2-wire RS 485 RTU Configurable via the display terminal or the PowerSuite software workshop: 9600 bps or 19200 bps Fixed = 8 bits, even parity, 1 stop Modbus RJ45 network port

Format

Configurable via the display terminal or the PowerSuite software workshop: 4800 bps, 9600 bps, 19200 bps or 38.4 Kbps Configurable via the display terminal or the PowerSuite software workshop: - 8 bits, odd parity, 1 stop - 8 bits, even parity, 1 stop - 8 bits, no parity, 1 stop - 8 bits, no parity, 2 stop

Polarization Address

No polarization impedances These should be provided by the wiring system (for example, in the master) 1 to 247, configurable via the display terminal or the PowerSuite software workshop. 3 addresses can be configured in order to access the drive data, the Controller Inside programmable card and the communication card respectively. These 3 addresses are identical for the connector and network ports. Read Holding Registers (03) 63 words maximum Write Single Register (06) Write Multiple Registers (16) 61 words maximum Read/Write Multiple Registers (23) 63/59 words maximum Read Device Identification (43) Diagnostics (08) Can be inhibited. Time out, which can be set between 0.1 s and 30 s An activity LED on integrated 7-segment display terminal. One LED for each port. One activity LED Command word received Reference received For each port: b Number of frames received b Number of incorrect frames 9-way male SUB-D connector on CANopen adapter. This connects to the Modbus RJ45 network port. Slave 20 Kbps, 50 Kbps, 125 Kbps, 250 Kbps, 500 Kbps or 1 Mbps 1 to 127, configurable via the display terminal or the PowerSuite software workshop. 3 receive and 3 transmit (PDO1, PDO2 and PDO3) Event-triggered, Time-triggered, Remotely-requested, Sync (cyclic), Sync (acyclic) Yes Configurable (PDO1 and PDO2) 1 server Yes CiA DS 301, V 4.02 CiA DSP 402: CANopen Device Profile Drives and Motion Control Node Guarding, Heartbeat 2 LEDs: RUN and ERROR on integrated 7-segment display terminal 2 LEDs: RUN and ERROR Command word received Reference received Display of received PDOs Display of transmitted PDOs State of NMT chart Received PDOs counter Transmitted PDOs counter Reception error counter Transmission error counter A single eds file is supplied on the CD-ROM containing the documentation for the whole range. It contains the description of the drive parameters.

Services

Message handling

Communication monitoring Diagnostics With LEDs With graphic display terminal

CANopen protocol
Structure Connector Network management Transmission speed Address (Node ID) Number of PDOs PDO modes PDO linking PDO mapping Number of SDOs Emergency CANopen application layer Profile Communication monitoring With LEDs With graphic display terminal and PowerSuite software workshop

Services

Diagnostics

Description file

Presentation: pages 6 to 8

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

15

Operation

Variable speed drives for asynchronous motors


Altivar 71

Torque characteristics (typical curves) The curves below define the available continuous torque and transient overtorque for both force-cooled and self-cooled motors. The only difference is in the ability of the motor to provide a high continuous torque at less than half the nominal speed.
T/Tn C/Cn 2,25 2,20

4 3

2 1,75 1,70 1,50 1,25 1 0,95 0,75

Open loop applications 1 Self-cooled motor: continuous useful torque (1) 2 Force-cooled motor: continuous useful torque 3 Overtorque for 60 s maximum 4 Transient overtorque for 2 s maximum 5 Torque in overspeed at constant power (2)

2 5 1

0,50 0,25 0 0 25/30 50/60 75/90 100/120 Hz

Open loop applications

T/Tn 2,25 2,20

4 3

2
1,75 1,70 1,50 1,25 1 0,75 0,50 0,25
0

Closed loop applications 1 Self-cooled motor: continuous useful torque (1) 2 Force-cooled motor: continuous useful torque 3 Overtorque for 60 s maximum 4 Transient overtorque for 2 s maximum 5 Torque in overspeed at constant power (2) Altivar 71 drives are capable of supplying nominal torque continuously at zero speed.

2 1

2 1 5

25/30

50/60

75/90

100/120

Hz

Closed loop applications

Motor thermal protection


Altivar 71 drives feature thermal protection designed specifically for self-cooled or forced-cooled variable speed motors. The drive calculates the motor thermal state even when it is switched off. This motor thermal protection is designed for a maximum ambient temperature of 40C around the motor. If the temperature around the motor exceeds 40C, thermal protection should be provided directly by thermistor probes (PTC) integrated in the motor. The probes are managed directly by the drive.
(1) For power ratings y 250 W, motor derating is 20% instead of 50% at very low frequencies. (2) The motor nominal frequency and the maximum output frequency can be adjusted from 10 to 500 Hz or 1000 Hz depending on the rating. Check the mechanical overspeed characteristics of the selected motor with the manufacturer.

Presentation: pages 6 to 9

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

16

Global Catalog. Refer to Statement of Scope on page 2.

Operation (continued)

Variable speed drives for asynchronous motors


Altivar 71

Special uses
Using Altivar 71 drives with synchronous motors Altivar 71 drives are also suitable for powering synchronous motors (sinusoidal electromotive force) in open loop mode and are used to achieve performance levels comparable to those associated with an asynchronous motor in sensorless Flux Vector Control. This drive/motor combination makes it possible to obtain remarkable speed accuracy and maximum torque even at zero speed. The design and construction of synchronous motors is such that they offer enhanced power density and speed dynamics in a compact unit. Drive control for synchronous motors does not cause stalling. Using high-speed special motors These motors are designed for constant torque applications with high frequency ranges. The Altivar 71 supports operating frequencies of up to 1000 Hz. By design, this type of motor is more sensitive to overvoltages than a standard motor. Different solutions are available: b Overvoltage limitation function b Output filters The drives 5-point voltage/frequency control ratio is particularly well-suited as it avoids resonance. Using a motor at overspeed The maximum output frequency can be adjusted from 10 to 1000 Hz for drives rated less than or equal to 37 kW and from 10 to 500 Hz for higher ratings. When using a standardized asynchronous motor at overspeed, check the mechanical overspeed characteristics of the selected motor with the manufacturer. Above its nominal speed corresponding to a frequency of 50/60 Hz, the motor operates with a decreasing flux and its torque decreases significantly (see the curve opposite). The application must be able to permit this type of low-torque, high-speed operation. 1 Machine torque (degressive torque) 2 Machine torque (low motor torque) 3 Continuous motor torque Typical applications: wood-working machinery, broaching machines, high-speed hoisting, etc Motor power less than drive power An Altivar 71 drive can power any motor with a rating lower than that for which the drive was designed. This motor/drive combination makes it suitable for applications requiring high, intermittent overtorque. Typical applications: machines with very high starting torque, grinders, kneaders, etc
Note: in this case, it is advisable to over-rate the drive to the next standard power rating immediately above that of the motor.

T/Tn 1 0,95

0,75

1 3

0,50

0,25

0 0 25/30 50/60 75/90 100/120 Hz

Using a motor at overspeed

Example: Use an 11 kW motor with a 15 kW drive.


I/In motor

1,25 1 0,95 0,75

2 2 1 1

Power of a self-cooled motor greater than the drive power This motor/drive combination makes it possible to use a self-cooled motor for a greater speed range in continuous operation. The use of a motor with a higher power rating than that of the drive is only possible if the current drawn by this motor is less than or equal to the nominal drive current.
Note: Limit the motor power to the standard rating immediately above that of the drive.

0,50

Example: On a single machine, the use of a 2.2 kW drive combined with a 3 kW motor means that the machine can operate at its nominal power (2.2 kW) at low speed. 1 Motor power = drive power = 2.2 kW 2 2.2 kW drive combined with a 3 kW motor: greater speed range at 2.2 kW.

0,25

0 0 10/12 25/30 50/60 Hz

Power of a self-cooled motor greater than the drive power

Presentation: pages 6 to 9

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

17

Operation (continued)

Variable speed drives for asynchronous motors


Altivar 71

Special uses (continued)


Altivar 71
Output filter

In1

M1

In2

M2

Connecting motors in parallel The nominal current of the drive must be greater than or equal to the sum of the currents of the motors to be controlled. In this case, provide external thermal protection for each motor using probes or thermal overload relays. For cable runs over a certain length, taking account of all tap links, it is advisable either to install an output filter between the drive and the motors or to use the overvoltage limitation function. If several motors are used in parallel, there are 2 possible scenarios: b The motors have equal power ratings, in which case the torque characteristics will remain optimized after the drive has been configured b The motors have different power ratings, in which case the torque characteristics will not be optimized for all the motors

Inx
In drive > In1 + In2 + Inx

Mx

Connecting motors in parallel

Altivar 71 2,2 kW

2,2 kW 1500 tr/min

50 Hz

Identical motor
3,8 kW 2600 tr/min

Altivar 71 4 kW

Using a motor at constant torque up to 87/104 Hz A 400 V, 50 Hz motor in connection can be used at constant torque up to 87 Hz if it is in connection. In this particular case, the initial motor power, as well as the power of the first associated drive are multiplied by (it is therefore important to select a drive with a 3 suitable rating). Example: A 2.2 kW, 50 Hz motor in connection supplies 3.8 kW at 87 Hz with a connection.
Note: Check the motors overspeed operating characteristics.

87 Hz

U (V) 400

230

50/60

87/104

Hz

Using a motor at constant torque up to 87/104 Hz

Using special motors


Special brake motors: tapered rotor or flux bypass

The magnetic field releases the brake. This type of operation with the Altivar 71 drive requires application of the voltage/frequency ratio.
Note: The no-load current may be high, operation at low speed can only be intermittent.

Resistive rotor asynchronous motors Different motor control ratios available on the Altivar 71 make it possible to apply specific settings when using high-slip motors.

Presentation: pages 6 to 9

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

18

Global Catalog. Refer to Statement of Scope on page 2.

Operation (continued)

Variable speed drives for asynchronous motors


Altivar 71

Special uses (continued)


Switching the motor at the drive output The drive can be switched when locked or unlocked. If the drive is switched on-thefly (drive unlocked), the motor is controlled and accelerates until it reaches the reference speed smoothly following the acceleration ramp. This use requires configuration of the automatic catching a spinning load ("catch on the fly") and the motor phase loss on output cut functions. Typical applications: loss of safety circuit at drive output, bypass function, switching of motors connected in parallel On new installations, it is recommended that the Power Removal safety function is used.
t t1 1 KM1 0
t1: deceleration without ramp (freewheel) t2: acceleration with ramp

KM1 Altivar 71 M

t2

Example of loss of output contactor

Test on a low power motor or without a motor In a testing or maintenance environment the drive can be checked without having to switch to a motor with the same rating as the drive (particularly useful in the case of high power drives). This use requires deactivation of motor phase loss function.

Presentation: pages 6 to 9

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 107

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

19

Catalog numbers

Variable speed drives for asynchronous motors


Altivar 71
Supply voltage 200...240 V 50/60 Hz

Motor Power indicated on plate (1) kW


533158

HP 0.5 1 2 3 5 7.5

Line supply Line current (2) 200 V 240 V A A 6.9 12 18.2 25.9 25.9 34.9 47.3 5.8 9.9 15.7 22.1 22 29.9 40.1

Apparent power 240 V kVA 2.4 4.1 6.5 9.2 9.1 12.4 16.7

Max. prospective line Isc kA 5 5 5 5 5 5 22

Altivar 71 Maximum Max. transient Catalog number (3) continuous current for current (1) 60 s 2s A A A 3 4.8 8 11 13.7 17.5 27.5 4.5 7.2 12 16.5 20.6 26.3 41.3 4.9 7.9 13.2 18.1 22.6 28.8 45.3 ATV 71H075M3 (4) ATV 71HU15M3 (4) ATV 71HU22M3 (4) ATV 71HU30M3 (4) ATV 71HU40M3 (4) (5) ATV 71HU55M3 (4) (5) ATV 71HU75M3 (4) (5)

Weight

kg 3.000 3.000 3.000 4.000 4.000 5.500 5.500

Single phase supply voltage: 200240 V 50/60 Hz


0.37 0.75 1.5 2.2 3 4 5.5

ATV 71HU22M3Z

3-phase supply voltage: 200240 V 50/60 Hz


0.37 0.75 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 0.5 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 3.5 6.1 11.3 15 19.3 25.8 35 45 53.3 71.7 77 88 124 141 167 200 271 3.1 5.3 9.6 12.8 16.4 22.9 30.8 39.4 45.8 61.6 69 80 110 127 147 173 232 1.3 2.2 4 5.3 6.8 9.5 12.8 16.4 19 25.6 28.7 33.3 45.7 52.8 61.1 71.9 96.4 5 5 5 5 5 5 22 22 22 22 22 22 22 22 22 35 35 3 4.8 8 11 13.7 17.5 27.5 33 54 66 75 88 120 144 176 221 285 4.5 7.2 12 16.5 20.6 26.3 41.3 49.5 81 99 112 132 180 216 264 332 428 4.9 7.9 13.2 18.1 22.6 28.8 45.3 54.5 89.1 109 124 145 198 238 290 365 470 ATV 71H037M3 (4) ATV 71H075M3 (4) ATV 71HU15M3 (4) ATV 71HU22M3 (4) ATV 71HU30M3 (4) ATV 71HU40M3 (4) ATV 71HU55M3 (4) ATV 71HU75M3 (4) ATV 71HD11M3X (4) (6) ATV 71HD15M3X (4) (6) ATV 71HD18M3X (6) ATV 71HD22M3X (6) ATV 71HD30M3X (6) ATV 71HD37M3X (6) ATV 71HD45M3X (6) ATV 71HD55M3X (6) (7) (8) ATV 71HD75M3X (6) (7) (8) 3.000 3.000 3.000 4.000 4.000 4.000 5.500 7.000 9.000 9.000 19.000 19.000 39.000 39.000 39.000 59.000 72.000
532725

ATV 71H037M3

532724

ATV 71HD37M3X

(1) These values are for a nominal switching frequency of 2.5 or 4 kHz, depending on the rating, for continuous operation. The switching frequency is adjustable from 116 kHz up to ATV 71HD45M3X and from 18 kHz for ATV 71HD55M3X and ATV 71HD75M3X drives. Above 2.5 or 4 kHz, depending on the rating, the drive decreases the switching frequency itself in the event of excessive temperature rise. For continuous operation above the nominal switching frequency, derate the nominal drive current (see derating curves on pages 135 and 137 to 139). (2) Typical value for the indicated motor power and for the maximum prospective line Isc. (3) To order a special reinforced version for difficult environmental conditions, add S337 at the end of the catalog number (except for ATV 71HpppM3X). (See the characteristics on page 10). Example: ATV 71H037M3 becomes ATV 71H037M3S337. For ATV 71HpppM3X, add 337 at the end of the catalog number. Example: ATV 71HD11M3X becomes ATV 71HD11M3X337. In this case, the drive is supplied with a remote graphic display terminal. (4) Drive supplied with a remote graphic display terminal. To receive a drive without a graphic display terminal, add a Z at the end of the catalog number. It will then be equipped with an integrated 7-segment display terminal. This option is not available for drives operating in difficult environmental conditions (3). Example: ATV 71H037M3 without graphic terminal becomes ATV 71H037M3Z. (5) A line choke must be used (see page 74). (6) Drive supplied without EMC filters. EMC filters are available as an option (see page 80). (7) Drive supplied as standard with a DC choke, which must be used when connecting the drive to the 3-phase supply. For connections to the DC bus, the drive can be ordered without a DC choke by adding D at the end of the catalog number. Example: ATV 71HD55M3X becomes ATV 71HD55M3XD. (8) Drive supplied without plate for EMC mounting. It is included in the kits for NEMA type 1, IP 21 or IP 31 conformity, to be ordered separately (see pages 24 and 25). Note: please refer to the compatibility tables summarizing the possible combinations for drives, options and accessories on pages 88 to 91.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Dimensions: pages 92 to 105

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

20

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers (continued)

Variable speed drives for asynchronous motors


Altivar 71
Supply voltage 380..0.480 V 50/60 Hz

Motor Power indicated on plate (1) kW


532723

Line supply Line current (2) 380 V 480 V A A 3.7 5.8 8.2 10.7 14.1 20.3 27 36.6 48 45.5 50 66 84 104 120 167 166 202 239 289 357 396 444 494 555 637 709 876 3 5.3 7.1 9 11.5 17 22.2 30 39 37.5 42 56 69 85 101 137 134 163 192 233 286 320 357 396 444 512 568 699

Apparent power 380 V kVA 2.4 3.8 5.4 7 9.3 13.4 17.8 24.1 31.6 29.9 32.9 43.4 55.3 68.5 79 109.9 109.3 133 157.3 190.2 235 260.6 292.2 325.1 365.3 419.3 466.6 576.6

Max. prospective line Isc kA 5 5 5 5 5 22 22 22 22 22 22 22 22 22 22 22 35 35 35 50 50 50 50 50 50 50 50 50

Altivar 71 Maximum continuous current (1) A 2.3 4.1 5.8 7.8 10.5 14.3 17.6 27.7 33 41 48 66 79 94 116 160 179 215 259 314 387 427 481 550 616 671 759 941

Max. transient Catalog number current for 60 s A 3.5 6.2 8.7 11.7 15.8 21.5 26.4 41.6 49.5 61.5 72 99 118.5 141 174 240 269 323 388 471 580 640 721 825 924 1006 1138 1411 2s A 3.8 6.8 9.6 12.9 17.3 23.6 29 45.7 54.5 67.7 79.2 109 130 155 191 264 295 355 427 518 638 704 793 907 1016 1107 1252 1552 ATV 71H075N4 (3) (4) ATV 71HU15N4 (3) (4) ATV 71HU22N4 (3) (4) ATV 71HU30N4 (3) (4) ATV 71HU40N4 (3) (4) ATV 71HU55N4 (3) (4) ATV 71HU75N4 (3) (4) ATV 71HD11N4 (3) (4) ATV 71HD15N4 (3) (4) ATV 71HD18N4 (3) ATV 71HD22N4 (3) ATV 71HD30N4 (3) ATV 71HD37N4 (3) ATV 71HD45N4 (3) ATV 71HD55N4 (3) ATV 71HD75N4 (3) ATV 71HD90N4 (5) (6) ATV 71HC11N4 (5) (6) ATV 71HC13N4 (5) (6) ATV 71HC16N4 (5) (6) ATV 71HC20N4 (5) (6) ATV 71HC25N4 (5) (6) ATV 71HC28N4 (5) (6) ATV 71HC31N4 (5) (6) ATV 71HC40N4 (5) (6) ATV 71HC50N4 (5) (6)

Weight

HP 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400 450 500 600 700

kg 3.000 3.000 3.000 4.000 4.000 5.500 5.500 7.000 9.000 9.000 19.000 26.000 26.000 44.000 44.000 44.000 60.000 74.000 80.000 110.000 140.000 140.000 140.000 215.000 225.000 300.000

3-phase supply voltage: 380480 V 50/60 Hz


0.75 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 220 250 280 315 355 400 500

ATV 71HU22N4

533158

ATV 71HU40N4Z

533249

ATV 71HC28N4

(1) These values are for a nominal switching frequency of 2.5 or 4 kHz, depending on the rating, for continuous operation. The switching frequency is adjustable from 116 kHz up to ATV 71HD75N4 and from 2.58 kHz for ATV 71HD90N4ATV 71HC50N4 drives. Above 2.5 or 4 kHz, depending on the rating, the drive decreases the switching frequency itself in the event of excessive temperature rise. For continuous operation above the nominal switching frequency, derate the nominal drive current (see derating curves on pages 135 and 137 to 139). (2) Typical value for the indicated motor power and for the maximum prospective line Isc. (3) To order a special reinforced version for difficult environmental conditions, add S337 at the end of the catalog number (see the characteristics on page 10). Example: ATV 71H075N4 becomes ATV 71H075N4S337. In this case, the drive is supplied with a remote graphic display terminal. ATV 71HD90N4HC50N4 drives have been specially designed to operate in difficult environmental conditions. (4) Drive supplied with a remote graphic display terminal. To receive a drive without a graphic display terminal, add a Z at the end of the catalog number. It will then be equipped with an integrated 7-segment display terminal. This option is not available for drives operating in difficult environmental conditions (3). Example: ATV 71H075N4 without graphic terminal becomes ATV 71H075N4Z. (5) Drive supplied as standard with a DC choke, which must be used when connecting the drive to the 3-phase supply. For connections to the DC bus, the drive can be ordered without a DC choke by adding D at the end of the catalog number. Example: ATV 71HD90N4 becomes ATV 71HD90N4D. (6) Drive supplied without plate for EMC mounting. It is included in the kits for NEMA type 1, IP 21 or IP 31 conformity, to be ordered separately (see pages 24 and 25). Note: please refer to the compatibility tables summarizing the possible combinations for drives, options and accessories on pages 88 to 91.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Dimensions: pages 92 to 105

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

21

Presentation, Catalog numbers

Variable speed drives for asynchronous motors


Altivar 71
Options: accessories
Adaptor for 115 V a logic inputs
This adaptor is used to connect 115 V a logic signals to the logic inputs on the drive or an I/O extension card. 7 logic inputs with capacitive impedance at 60 Hz of 0.22 F are available for connecting the logic signals: b Max. current: 200 mA b Response time: 5 ms to change from state 0 to state 1, 20 ms to change from state 1 to state 0 b Logic state 0 for a voltage below 20 V, logic state 1 for a voltage between 70 V and 132 V The power supply must be provided by a 115 V a external power supply (min. 70 V, max. 132 V). Catalog numbers
Description Adaptor for 115 V a logic inputs Catalog number VW3 A3 101

Weight kg

Control card fan kit


1
This kit is required for ATV 71HD18M3X, HD22M3X and ATV 71HD22N4HD75N4 drives. It enables the drive to operate at an ambient temperature of 50C to 60C, for example if it is mounted in an IP 54 enclosure. The circulation of air around the electronic cards prevents the formation of hot spots. Check the derating to be applied to the drive nominal current (see the derating curves on pages 135 and 137 to 139). The kit 1 is mounted on the upper part of the drive. It is powered by the drive. It consists of: b A fan subassembly b Fixing accessories b A manual Catalog numbers
For drives ATV 71HD18M3X, HD22M3X ATV 71HD22N4HD37N4 ATV 71HD45N4HD75N4 Catalog number VW3 A9 406 VW3 A9 407 Weight kg
533236

Dimensions: page 95

22

Global Catalog. Refer to Statement of Scope on page 2.

Presentation, catalog numbers (continued)

Variable speed drives for asynchronous motors


Altivar 71
Options: accessories

Kit for flush-mounting in a dust and damp proof enclosure


This kit can be used to mount the power part of the drive outside the enclosure (IP 54 degree of protection), which reduces the power dissipated into the enclosure (see page 140). With this type of mounting, the maximum internal temperature in the enclosure can then reach 60C without it being necessary to derate the drive current. Between 50C and 60C, for ATV 71HD18M3X, HD22M3X and ATV 71HD22N4HD75N4 drives, a control card fan kit must be used to prevent hot spots (see page 22). The back of the enclosure must be drilled and cut out for this type of mounting. The kit consists of: b A metal frame of the right size for the drive rating b Corner pieces b Seals b A fan support (This can be used to move the fans so that they can be accessed from the front of the enclosure.) b Fixing accessories b A cutting and drilling template b A manual Catalog numbers
For drives ATV 71H037M3HU15M3 ATV 71H075N4HU22N4 ATV 71HU22M3HU40M3 ATV 71HU30N4, HU40N4 ATV 71HU55M3 ATV 71HU55N4, HU75N4 ATV 71HU75M3 ATV 71HD11N4 ATV 71HD11M3X, HD15M3X ATV 71HD15N4, HD18N4 ATV 71HD18M3X, HD22M3X ATV 71HD22N4 ATV 71HD30N4, HD37N4 ATV 71HD30M3XHD45M3X ATV 71HD45N4HD75N4 ATV 71HD55M3X ATV 71HD90N4 ATV 71HD75M3X ATV 71HC11N4 ATV 71HC13N4 ATV 71HC16N4 ATV 71HC20N4HC28N4 ATV 71HC31N4, HC40N4 ATV 71HC50N4 Catalog number VW3 A9 501 VW3 A9 502 VW3 A9 503 VW3 A9 504 VW3 A9 505 VW3 A9 506 VW3 A9 507 VW3 A9 508 VW3 A9 509 VW3 A9 510 VW3 A9 511 VW3 A9 512 VW3 A9 513 VW3 A9 514 VW3 A9 515 VW3 A9 516 VW3 A9 517 Weight kg 2.700 3.100 3.700 4.600 4.900 3.900 4.200 4.900 5.200 5.100 3.600 4.300 4.400 4.700 4.700 5.900 6.200
533254

ATV 71HU75N4 flush-mounted

533255

ATV 71HC28N4D flush-mounted

Without braking unit With braking unit

Dimensions: pages 96 to 98

Global Catalog. Refer to Statement of Scope on page 2.

23

Presentation, catalog numbers (continued)

Variable speed drives for asynchronous motors


Altivar 71
Options: accessories

Kit for NEMA Type 1 conformity (mounting outside the enclosure) When the drive is mounted directly on a wall outside the enclosure, this kit can be used to ensure NEMA Type 1 conformity when connecting the cables with a tube. The shielding is connected inside the kit.
For ATV 71HpppM3, ATV 71HD11M3XHD45M3X and ATV 71H075N4HD75N4 drives, the kit consists of: b All the mechanical parts, including a pre-cut plate for connecting the conduit b Hardware b A manual For ATV 71HD55M3X, HD75M3X and ATV 71HD90N4HC50N4 drives, the kit consists of: b A pre-drilled plate for connecting the conduit b Hardware b A manual Catalog numbers
For drives ATV 71H037M3HU15M3 ATV 71H075N4HU22N4 ATV 71HU22M3HU40M3 ATV 71HU30N4, HU40N4 ATV 71HU55M3 ATV 71HU55N4, HU75N4 ATV 71HU75M3 ATV 71HD11N4 ATV 71HD11M3X, HD15M3X ATV 71HD15N4, HD18N4 ATV 71HD18M3X, HD22M3X ATV 71HD22N4 ATV 71HD30N4, HD37N4 ATV 71HD30M3XHD45M3X ATV 71HD45N4HD75N4 ATV 71HD55M3X ATV 71HD90N4 ATV 71HD75M3X ATV 71HC11N4 ATV 71HC13N4 ATV 71HC16N4 ATV 71HC20N4HC28N4 Catalog number VW3 A9 201 VW3 A9 202 VW3 A9 203 VW3 A9 204 VW3 A9 205 VW3 A9 206 VW3 A9 207 VW3 A9 208 VW3 A9 209 VW3 A9 210 VW3 A9 211 VW3 A9 212 VW3 A9 213 VW3 A9 214 Weight kg 1.300 1.500 1.800 2.000 2.800 4.000 5.000 7.000 9.400 11.800 11.600 14.600 19.500 19.500

Without braking unit With braking unit

Dimensions: page 99

24

Global Catalog. Refer to Statement of Scope on page 2.

Presentation, catalog numbers (continued)

Variable speed drives for asynchronous motors


Altivar 71
Options: accessories

Kits for IP 21 or IP 31 conformity (mounting outside the enclosure) When the drive is mounted directly on a wall outside the enclosure, this kit can be used to ensure conformity with IP 21 or IP 31 degree of protection when connecting the cables with a cable gland. The shielding is connected inside the kit.
For ATV 71HpppM3, ATV 71HD11M3XHD45M3X and ATV 71H075N4HD75N4 drives, the kit conforms to IP 21 degree of protection. It consists of: b All the mechanical parts 1 including a drilled plate 2 for fixing the cable glands 3 b Fixing accessories b A manual For ATV 71HD55M3X, HD75M3X and ATV 71HD90N4HC50N4 drives, the kit conforms to IP 31 degree of protection. It consists of: b An IP 54 casing 4 used to maintain the IP 54 degree of protection for the power part b An EMC plate with cable clamps 5 b An IP 31 cover 6 b Fixing accessories b A manual

533326

3
Catalog numbers
For drives ATV 71H037M3HU15M3 ATV 71H075N4HU22N4 ATV 71HU22M3HU40M3 ATV 71HU30N4, HU40N4 ATV 71HU55M3 ATV 71HU55N4, HU75N4 ATV 71HU75M3 ATV 71HD11N4 ATV 71HD11M3X, HD15M3X ATV 71HD15N4, HD18N4 ATV 71HD18M3X, HD22M3X ATV 71HD22N4 ATV 71HD30N4, HD37N4 ATV 71HD30M3XHD45M3X ATV 71HD45N4HD75N4 ATV 71HD55M3X ATV 71HD90N4 ATV 71HD75M3X ATV 71HC11N4 ATV 71HC13N4 ATV 71HC16N4 ATV 71HC20N4HC28N4 Without braking unit With braking unit ATV 71HC31N4, HC40N4 ATV 71HC50N4 Degree of Catalog number protection IP 21 VW3 A9 101 IP 21 IP 21 IP 21 IP 21 IP 21 IP 21 IP 21 IP 31 IP 31 IP 31 IP 31 IP 31 IP 31 IP 31 IP 31 VW3 A9 102 VW3 A9 103 VW3 A9 104 VW3 A9 105 VW3 A9 106 VW3 A9 107 VW3 A9 108 VW3 A9 109 VW3 A9 110 VW3 A9 111 VW3 A9 112 VW3 A9 113 VW3 A9 114 VW3 A9 115 VW3 A9 116 Weight kg 1.300 1.500 1.800 2.000 2.800 4.000 5.000 7.000 9.400 11.800 11.600 14.600 19.500 19.500 25.000 35.000

533327

Dimensions: page 99

Global Catalog. Refer to Statement of Scope on page 2.

25

Presentation, catalog numbers (continued)

Variable speed drives for asynchronous motors


Altivar 71
Options: accessories

Substitution kit for Altivar 58 or Altivar 58F drives


This kit 1 is used to fit an Altivar 71 drive in the place of an Altivar 58 or Altivar 58F drive using the same fixing holes. It includes the mechanical adaptors required for mounting.

Kits
Old drive Motor Power kW HP Replaced by Catalog number Weight kg

533238

Supply voltage 200240 V single phase High torque application (170% Tn)
ATV 58HU09M2 ATV 58HU18M2 ATV 58HU29M2 ATV 58HU41M2 ATV 58HU72M2 ATV 58HU90M2 ATV 58HD12M2 0.37 0.75 1.5 2.2 3 4 5.5 0.5 1 2 3 5 7.5 ATV 71H075M3 ATV 71HU15M3 ATV 71HU22M3 ATV 71HU30M3 ATV 71HU40M3 ATV 71HU55M3 ATV 71HU75M3 VW3 A9 301 VW3 A9 301 VW3 A9 303 VW3 A9 303 VW3 A9 304 VW3 A9 306 VW3 A9 306

Supply voltage 200240 V three-phase High torque application (170% Tn)


ATV 58HU29M2 ATV 58HU41M2 ATV 58HU54M2 ATV 58HU72M2 ATV 58HU90M2 ATV 58HD12M2 ATV 58HD16M2X ATV 58HD23M2X ATV 58HD28M2X ATV 58HD33M2X ATV 58HD46M2X 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 2 3 5 7.5 10 15 20 25 30 40 ATV 71HU15M3 ATV 71HU22M3 ATV 71HU30M3 ATV 71HU40M3 ATV 71HU55M3 ATV 71HU75M3 ATV 71HD11M3X ATV 71HD15M3X ATV 71HD18M3X ATV 71HD22M3X ATV 71HD30M3X VW3 A9 302 VW3 A9 303 VW3 A9 304 VW3 A9 304 VW3 A9 306 VW3 A9 307 VW3 A9 309 VW3 A9 309 VW3 A9 312 VW3 A9 312 VW3 A9 314

VW3 A9 304

Supply voltage 380480 V three-phase High torque application (170% Tn)


ATV 58HU18N4 ATV 58HU29N4 ATV 58HU41N4 ATV 58HU54N4 ATV 58HU72N4 ATV 58HU90N4 ATV 58HD12N4 ATV 58HD16N4 ATV 58HD23N4 ATV 58HD28N4 ATV 58HD33N4 ATV 58HD46N4 ATV 58HD54N4 ATV 58HD64N4 ATV 58HD79N4 0.75 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 ATV 71H075N4 ATV 71HU15N4 ATV 71HU22N4 ATV 71HU30N4 ATV 71HU40N4 ATV 71HU55N4 ATV 71HU75N4 ATV 71HD11N4 ATV 71HD15N4 ATV 71HD18N4 ATV 71HD22N4 ATV 71HD30N4 ATV 71HD37N4 ATV 71HD45N4 ATV 71HD55N4 VW3 A9 302 VW3 A9 302 VW3 A9 303 VW3 A9 304 VW3 A9 304 VW3 A9 305 VW3 A9 306 VW3 A9 307 VW3 A9 308 VW3 A9 309 VW3 A9 310 VW3 A9 311 VW3 A9 313 VW3 A9 315 VW3 A9 315

26

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers (continued)

Variable speed drives for asynchronous motors


Altivar 71
Options: accessories

533237

Kits (continued)
Old drive Motor Power kW HP Replaced by Catalog number Weight kg

Supply voltage 200240 V three-phase Standard torque applications (120% Tn)


ATV 58HD16M2X ATV 58HD23M2X ATV 58HD28M2X ATV 58HD33M2X ATV 58HD46M2X 15 18.5 22 30 37 20 25 30 40 50 ATV 71HD15M3X ATV 71HD18M3X ATV 71HD22M3X ATV 71HD30M3X ATV 71HD37M3X VW3 A9 309 VW3 A9 310 VW3 A9 312 VW3 A9 314 VW3 A9 314

Supply voltage 380480 V three-phase Standard torque applications (120% Tn)


ATV 58HD28N4 ATV 58HD33N4 ATV 58HD46N4 ATV 58HD54N4 ATV 58HD64N4 ATV 58HD79N4 22 30 37 45 55 75 30 40 50 60 75 100 ATV 71HD22N4 ATV 71HD30N4 ATV 71HD37N4 ATV 71HD45N4 ATV 71HD55N4 ATV 71HD75N4 VW3 A9 310 VW3 A9 311 VW3 A9 311 VW3 A9 315 VW3 A9 315 VW3 A9 315

VW3 A9 315

Global Catalog. Refer to Statement of Scope on page 2.

27

Presentation, catalog numbers

Variable speed drives for asynchronous motors


Altivar 71
Options: dialogue

Remote graphic display terminal


(this display terminal can be supplied with the drive or ordered separately) This display terminal is attached to the front of the drive. In the case of drives supplied without a graphic display terminal, it covers the integrated 7-segment display terminal. It can be: b Used remotely in conjunction with the appropriate accessories (see below) b Connected to several drives using multidrop link components (see page 29) It is used: b To control, adjust and configure the drive b To display the current values (motor, input/output values, etc.) b To save and download configurations; 4 configuration files can be saved. The terminals maximum operating temperature is 60C and it features IP 54 protection. Description 1 Graphic display: - 8 lines, 240 x 160 pixels - Large digits that can be read from 5 m away - Supports display of bar charts 2 Assignable function keys F1, F2, F3, F4: - Dialogue functions: direct access, help screens, navigation - Application functions: Local Remote, preset speed 3 STOP/RESET: local control of motor stop/fault reset 4 RUN: local control of motor operation 5 Navigation button: - Press: saves the current value (ENT) - Turn : increases or decreases the value, takes you to the next or previous line. 6 FWD/REV: reverses the direction of rotation of the motor 7 ESC: aborts a value, a parameter or a menu to return to the previous selection Note: Keys 3, 4 and 6 can be used to control the drive directly. Catalog numbers
Description Remote graphic display terminal N 1 Catalog number VW3 A1 101 Weight kg 0.145
522148

2 3 4 7 6

2 3

Graphic display terminal accessories


1
The available accessories are: b A remote mounting kit for mounting on an enclosure door with IP 54 degree of protection. It includes: v All the mechanical fittings v The screws and bolts b A transparent door which attaches to the remote mechanics to achieve IP 65 degree of protection b A cable equipped with two RJ45 connectors so that the graphic display terminal can be connected to the Altivar 71 drive (1, 3, 5 or 10 m lengths available) b An RJ45 female/female adapter for connecting the VW3 A1 101 graphic display terminal to the VW3 A1 104 Rppp remote cable Catalog numbers

5 1

Description Remote mounting kit (1) Door (2) Remote cables Equipped with 2 RJ45 connectors

N 2 3 4 4 4 4 5

RJ45 female/female adaptor (1) In this case, use a VW3 A1 104 Rpp remote connecting cable, which must be ordered separately (see above). (2) To be mounted on remote mounting kit VW3 A1 102 (for mounting on an enclosure door), which must be ordered separately (see above).

Length m 1 3 5 10

Degree of protection IP 54 IP 65

Weight kg VW3 A1 102 0.150 VW3 A1 103 0.040 VW3 A1 104 R10 0.050 VW3 A1 104 R30 0.150 VW3 A1 104 R50 0.250 VW3 A1 104 R100 0.500 VW3 A1 105 0.010

Catalog number

Dimensions: page 100

28

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers (continued)

Variable speed drives for asynchronous motors


Altivar 71
Options: dialogue

Multidrop link components


These components enable a graphic display terminal to be connected to several drives via a multidrop link. This multidrop link is connected to the Modbus terminal port on the front of the drive. Connection accessories
Description N 1 Sold in lots Unit of catalog number LU9 GC3 Weight kg 0.500

2
ATV 71

4
VW3 A1 102

1 6 3 6 2 2 6 2 3 2

Modbus splitter box 10 RJ45 connectors and 1 screw terminal With integrated Modbus 0.3 m cable T-junction boxes With integrated 1 m cable R = 120 For Modbus C = 1 nF RJ45 line connector terminator Remote For the VW3 A1 101 mounting kit graphic display terminal

2 2 3

VW3 A8 306 TF03 VW3 A8 306 TF10 VW3 A8 306 RC

0.010

VW3 A1 102

0.150

Connecting cables (equipped with 2 RJ45 connectors)


Used with N Length m 1 3 5 10 Modbus bus 6 0.3 1 3 Catalog number VW3 A1 104 R10 VW3 A1 104 R30 VW3 A1 104 R50 VW3 A1 104 R100 VW3 A8 306 R03 VW3 A8 306 R10 VW3 A8 306 R30 Weight kg 0.050 0.150 0.250 0.500 0.025 0.060 0.130

ATV 71

For remote operation of the Altivar 71 5 and the VW3 A1 101 graphic display terminal

Example of connection via multidrop link

PowerSuite software workshop


533219

PowerSuite software workshop

The PowerSuite software workshop offers the following benefits: b Messages can be displayed in plain text in several languages (English, French, German, Italian and Spanish) b Work can be prepared in the design office without having to connect the drive to the PC b Configurations and settings can be saved to floppy disk or hard disk and downloaded to the drive b Print facility b Altivar 58 or Altivar 58F files can be converted for transfer to an Altivar 71 drive b Oscillograms can be displayed See pages 178 to 181.

Dimensions: page 100

Global Catalog. Refer to Statement of Scope on page 2.

29

Presentation, characteristics

Variable speed drives for asynchronous motors


Altivar 71
Options: encoder interface cards

Presentation
Encoder interface cards are used for Flux Vector Control operation with sensor (FVC mode) which improves drive performance irrespective of the state of the motor load: b Zero speed torque b Accurate speed regulation b Torque accuracy b Shorter response times on a torque surge b Improved dynamic performance in transient state In other control modes (voltage vector control, voltage/frequency ratio), the encoder interface card improves static speed accuracy. Encoder interface cards can also be used for machine safety irrespective of the control type: b Overspeed detection b Load veering detection Encoder interface cards can also transmit an Altivar 71 drive reference provided by the encoder input. This use is specific to synchronizing the speed of several drives. Three types of card are available depending on the encoder technology: b RS 422 compatible differential outputs b open collector outputs (NPN) b push-pull outputs The card is inserted into a dedicated slot.
532727

VW3 A3 401

Characteristics
Encoder interface card with RS 422 compatible differential outputs
Type of card Power (supplied by the card) Maximum operating frequency Input signals Impedance Number of pulses/encoder revolution Maximum consumption current of encoder For a maximum cable Minimum recommended length of 25 m cross-section of conductors (3) For a maximum cable length of 50 m For a maximum cable length of 100 m For a maximum cable length of 1,000 m Voltage Maximum current VW3 A3 401 VW3 A3 402 5 V c (min. 5 V, max. 5.5 V) 15 V c (min. 15 V, max. 16 V) 200 mA 175 mA Short-circuit and overload protection 300 kHz A, A, B, B 440 5000 maximum The maximum high-speed frequency should not exceed 300 kHz 100 mA (1) 200 mA (1) 100 mA (2) 200 mA (2) 0.2 mm2 0.5 mm2 0.2 mm2 (AWG 24) (AWG 20) (AWG 24) 0.5 mm2 0.75 mm2 0.2 mm2 (AWG 20) (AWG 18) (AWG 24) 0.75 mm2 1.5 mm2 0.2 mm2 (AWG 18) (AWG 15) (AWG 24) 0.5 mm2 1 mm2 (AWG 20) (AWG 17) (1) Minimum encoder power supply 4.5 V. (2) Minimum encoder power supply 8 V. (3) Shielded cable containing 3 twisted pairs at intervals of between 20 and 50 mm. Connect the shielding to earth at both ends. Minimum recommended conductor cross-section for a minimum encoder voltage in order to limit line voltage drops.

Wiring diagrams: page 123

30

Global Catalog. Refer to Statement of Scope on page 2.

Characteristics (continued), catalog numbers

Variable speed drives for asynchronous motors


Altivar 71
Options: encoder interface cards

Characteristics (continued)
Encoder interface card with open collector outputs
Type of card Power (supplied by the card) Maximum operating frequency Input signals Impedance Number of pulses/encoder revolution Maximum consumption current of encoder For a maximum cable Minimum recommended length of 100 m cross-section of conductors (2) For a maximum cable length of 200 m For a maximum cable length of 500 m For a maximum cable length of 1,000 m Voltage Maximum current VW3 A3 403 VW3 A3 404 12 V c (min. 12 V, max. 13 V) 15 V c (min. 15 V, max. 16 V) 175 mA Short-circuit and overload protection 300 kHz A, A, B, B 1 k 5000 maximum The maximum high-speed frequency should not exceed 300 kHz 100 mA (1) 175 mA (1) 100 mA (1) 175 mA (1) 0.2 mm2 0.5 mm2 0.2 mm2 (AWG 24) (AWG 20) (AWG 24) 0.5 mm2 0.75 mm2 0.2 mm2 (AWG 20) (AWG 18) (AWG 24) 1 mm2 1.5 mm2 0.5 mm2 (AWG 17) (AWG 15) (AWG 20) 0.75 mm2 1.5 mm2 (AWG 18) (AWG 15) VW3 A3 405 VW3 A3 406 VW3 A3 407 12 V c (min. 12 V, max. 13 V) 15 V c (min. 15 V, max. 16 V) 24 V c (min. 20 V, max. 30 V) 175 mA 100 mA Short-circuit and overload protection 300 kHz A, A, B, B 1 k 1.6 k If <1.5 V If > 7.7 V and < 13 V If > 7.7 V and < 16 V If > 11.5 V and < 25 V 5000 maximum The maximum high-speed frequency should not exceed 300 kHz 100 mA (1) 175 mA (1) 100 mA (1) 175 mA (1) 100 mA (2) 0.2 mm2 0.5 mm2 0.2 mm2 (AWG 24) (AWG 20) (AWG 24) 0.5 mm2 0.75 mm2 0.2 mm2 (AWG 20) (AWG 18) (AWG 24) 1 mm2 1.5 mm2 0.5 mm2 0.2 mm2 (AWG 17) (AWG 15) (AWG 20) (AWG 24) 0.75 mm2 1.5 mm2 0.5 mm2 (AWG 18) (AWG 15) (AWG 20)

Encoder interface card with push-pull outputs


Type of card Power (supplied by the card) Maximum operating frequency Input signals Impedance State 0 State 1 Number of pulses/encoder revolution Maximum consumption current of encoder For a maximum cable Minimum recommended length of 100 m cross-section of conductors (3) For a maximum cable length of 200 m For a maximum cable length of 500 m For a maximum cable length of 1,000 m Voltage Maximum current

Catalog numbers
Encoder interface cards (4)
Description Encoder interface cards with RS 422 compatible differential outputs Encoder interface cards with open collector outputs Encoder interface cards with push-pull outputs Voltage V 5 15 12 15 12 15 24 Catalog number VW3 A3 401 VW3 A3 402 VW3 A3 403 VW3 A3 404 VW3 A3 405 VW3 A3 406 VW3 A3 407 Weight kg 0.200 0.200 0.200 0,200 0.200 0.200 0.200

(1) Minimum encoder power supply 10 V. (2) Minimum encoder power supply 14 V. (3) Shielded cable containing 3 twisted pairs at intervals of between 20 and 50 mm. Connect the shielding to earth at both ends. Minimum recommended conductor cross-section for a minimum encoder voltage in order to limit line voltage drops. (4) The Altivar 71 cannot support more than one encoder interface card. Please refer to the compatibility tables summarizing the possible combinations for drives, options and accessories on pages 88 to 91.

Wiring diagrams: page 123

Global Catalog. Refer to Statement of Scope on page 2.

31

Presentation, characteristics

Variable speed drives for asynchronous motors


Altivar 71
Options: I/O extension cards

Presentation
532728

Altivar 71 drives can be specially adapted to particular application areas by installing I/O extension cards. Two models are available: b Card with logic I/O featuring: v 1 relay logic output (C/O contact) v 4 x 24 V c positive or negative logic inputs v 2 x 24 V c open collector positive or negative logic outputs v 1 input for PTC probes b Card with extended I/O featuring: v 1 differential current analog input (0 mA) 20 v 1 software-configurable voltage (0 V c) or current (0 mA) analog input 10 20 v 2 software-configurable voltage ( 10 V c, 0 V) or current (0 mA) analog 10 20 outputs v 1 relay logic output v 4 x 24 V c positive or negative logic inputs v 2 x 24 V c open collector positive or negative logic outputs v 1 input for PTC probes v 1 frequency control input

VW3 A3 202

Characteristics
Logic I/O card VW3 A3 201
Internal supplies available Short-circuit and overload protection: b 1 x 24 V c supply (min. 21 V, max. 27 V), maximum current 200 mA for the complete drive and I/O extension card assembly b 1 x - 10.5 V c supply ( 5%) for the reference potentiometer (1 to 10 k), max. current 10 mA R3A, R3B, R3C 1 relay logic output, one N/C contact and one N/O contact with common point. Minimum switching capacity: 3 mA for 24 V c Maximum switching capacity: b on resistive load (cos = 1): 5 A for 250 V a or 30 V c b on inductive load (cos = 0.4 and L/R = 7 ms): 2 A for 250 V a or 30 V c Electrical service life: 100,000 operations Maximum response time: 7 ms 0.5 ms 4 programmable logic inputs, 24 V c, compatible with level 1 PLC, IEC 65A-68 standard Impedance 3.5 k Maximum voltage: 30 V Multiple assignment makes it possible to configure several functions on one input Maximum sampling time: 2 ms 0.5 ms State 0 if y 5 V or logic input not wired, state 1 if u 11 V State 0 if u 16 V or logic input not wired, state 1 if y 10 V 2 assignable open collector positive logic (Source) outputs, compatible with level 1 PLC, IEC 65A-68 standard 24 V c internal or 24 V c external power supply (min. 12 V, max. 30 V) Maximum current: 200 mA Logic output common (CLO) isolated from other signals Maximum sampling time: 2 ms 0.5 ms. The active state is software-configurable as is a delay for each switching operation 1 input for a maximum of 6 PTC probes mounted in series: b nominal value < 1.5 k b trip resistance 3 k reset value 1.8 k , b short-circuit protection < 50 1.5 mm2 (AWG 16) 0.25 Nm

Configurable relay outputs

Logic inputs

LI7LI10

Positive logic (Source) Negative logic (Sink) Logic outputs LO1, LO2

Input for PTC probes

TH1+/TH1-

Maximum I/O connection capacity and tightening torque

Wiring diagrams: page 122

32

Global Catalog. Refer to Statement of Scope on page 2.

Characteristics (continued), catalog numbers

Variable speed drives for asynchronous motors


Altivar 71
Options: I/O extension cards

Characteristics (continued)
Extended I/O card VW3 A3 202
Internal supplies available Short-circuit and overload protection: b 1 x 24 V c supply (min. 21 V, max. 27 V), max. current 200 mA for the complete drive and I/O extension card assembly b 1 x - 10.5 V c supply ( 5%) for the reference potentiometer (1 to 10 k), max. current 10 mA 1 X-Y mA differential current analog input by programming X and Y from 0 to 20 mA, with impedance 250 Maximum sampling time: 5 ms 1 ms Resolution: 11 bits + 1 sign bit Accuracy: 0.6% for a temperature variation of 60C Linearity: 0.15% of the maximum value 1 software-configurable current or voltage analog input: b voltage analog input 0 V c, impedance 30 k (maximum safe voltage 24 V) 10 b X-Y mA current analog input by programming X and Y from 0 to 20 mA, with impedance 250 Maximum sampling time: 5 ms 1 ms Resolution: 11 bits Accuracy: 0.6% for a temperature variation of 60C Linearity: 0.15% of the maximum value 2 software-configurable current or voltage analog outputs: b voltage analog output 10 V c, 0 V, minimum load impedance 470 10 b X-Y mA current analog output by programming X and Y from 0 to 20 mA, maximum load impedance 500 Maximum sampling time: 5 ms 1 ms Resolution: 10 bits Accuracy: 1% for a temperature variation of 60C Linearity: 0.2% of the maximum value 1 relay logic output, one N/C contact and one N/O contact with common point. Minimum switching capacity: 3 mA for 24 V c Maximum switching capacity: b on resistive load (cos = 1): 5 A for 250 V a or 30 V c b on inductive load (cos = 0.4 and L/R = 7 ms): 1.5 A for 250 V a or 30 V c Electrical service life: 100,000 operations Maximum response time: 10 ms 1 ms 4 programmable logic inputs, 24 V c, compatible with level 1 PLC, IEC 65A-68 standard Impedance 3.5 k Maximum voltage: 30 V Multiple assignment makes it possible to configure several functions on one input Maximum sampling time: 5 ms 1 ms State 0 if y 5 V or logic input not wired, state 1 if u 11 V State 0 if u 16 V or logic input not wired, state 1 if y 10 V 2 x 24 V c assignable open collector positive logic (Source) or negative logic (Sink) outputs, compatible with level 1 PLC, IEC 65A-68 standard Maximum voltage: 30 V Maximum current: 200 mA Logic output common (CLO) isolated from other signals Maximum sampling time: 5 ms 1 ms. The active state is software-configurable as is a delay for each switching operation 1 input for a maximum of 6 PTC probes mounted in series: b nominal value < 1.5 k b trip resistance 3 k reset value 1.8 k , b short-circuit protection < 50 Frequency range: 0 kHz 30 Cyclic ratio: 50 % 10 % Maximum sampling time: 5 ms 1 ms Maximum input voltage 30 V, 15 mA Add a resistor if the input voltage is greater than 5 V (510 for 12 V, 910 for 15 V, 1.3 k for 24 V) State 0 if < 1.2 V, state 1 if > 3.5 V 1.5 mm2 (AWG 16) 0.25 Nm

Analog inputs AI

AI3+/AI3-

AI4

Analog outputs

AO2, AO3

Configurable relay outputs

R4A, R4B, R4C

Logic inputs

LI11LI14

Logic outputs

Positive logic (Source) Negative logic (Sink) LO3, LO4

Input for PTC probes

TH2+/TH2-

Frequency control input

RP

Maximum I/O connection capacity and tightening torque

Catalog numbers
I/O extension cards (1)
Description Logic I/O card Extended I/O card Catalog number VW3 A3 201 VW3 A3 202 Weight kg 0.300 0.300

(1) The Altivar 71 cannot support more than one I/O card with the same catalog number. Please refer to the compatibility tables summarizing the possible combinations for drives, options and accessories on pages 88 to 91.

Wiring diagrams: page 122

Global Catalog. Refer to Statement of Scope on page 2.

33

Presentation, description

Variable speed drives for asynchronous motors


Altivar 71
Option: Controller Inside programmable card

Presentation
The Controller Inside programmable card is used to adapt the variable speed drive to specific applications by integrating control system functions. Various predefined configurable applications are sold by Telemecanique and its partners. The PS 1131 software workshop for PC is used for programming and debugging new applications, quickly and in an open-ended manner (see page 37). It is not possible to transfer the program from the card to the PC, which enables us to protect our know-how. A single Controller Inside programmable card can be fitted in the Altivar 71 drive. It can be combined with another option card (I/O extension or communication). Consult the summary tables of possible drive, option and accessory combinations (see pages 88 to 91). The Controller Inside programmable card has: b 10 logic inputs, 2 of which can be used for 2 counters or 4 of which can be used for 2 incremental encoders b 2 analog inputs b 6 logic outputs b 2 analog outputs b A master port for the CANopen bus b A PC port for programming with the PS 1131 software workshop If the power consumption table does not exceed 200 mA, this card can be powered by the drive. Otherwise, an external 24 V c power supply must be used. The Controller Inside programmable card can also use: b The drive I/O b The I/O extension card I/O b The encoder interface card points counter b The drive parameters (speed, current, torque, etc)

Description
5 1 RJ45 connector for connecting the PS 1131 software workshop via an RS 485 serial link. Connection to the PC is via a cable and an RS 232/RS 485 converter included in the PowerSuite for PC connection kit, VW3 A8 106. 2 9-way male SUB-D connector for connection to the CANopen bus. 3 Connector with removable screw terminals, 6 contacts at intervals of 3.81 for the 24 V c power supply and 4 logic inputs. 4 3 connectors with removable screw terminals, 6 contacts at intervals of 3.81 for 6 logic inputs, 6 logic outputs, 2 analog inputs, 2 analog outputs and 2 commons. 1 2 3 5 b b b b 5 LEDs, comprising: 1 to indicate the presence of the 24 V c power supply 1 to indicate a program execution fault 2 to indicate the CANopen bus communication status 1 controlled by the application program
532835

Characteristics: page 36

Functions: pages 37 to 40

Catalog numbers: page 41

Wiring diagrams: page 123

34

Global Catalog. Refer to Statement of Scope on page 2.

Description (continued)

Variable speed drives for asynchronous motors


Altivar 71
Option: Controller Inside programmable card

ATV 71

XBT Magelis

Dialogue
Human-machine dialogue with the application programmed in the Controller Inside programmable card is possible using: b The Altivar 71 graphic display terminal b A Magelis industrial HMI terminal connected to the drive Modbus port b A Magelis industrial HMI terminal connected to the Ethernet TCP/IP network (if the drive is equipped with an Ethernet TCP/IP communication card) A graphic terminal menu is dedicated to the Controller Inside programmable card. This menu can be customized by the card program according to the application. Any industrial HMI terminal which supports the Modbus protocol can be used to display and modify the Controller Inside programmable card parameters. The drive Modbus server provides access to 2 Kwords (% MW, etc) in the card.

Modbus bus

Sensors

Independent machine with multiwire system

ATV 71

CANopen bus

Master CANopen communication


The master CANopen port on the Controller Inside programmable card can be used to extend the I/O capacity and to control other CANopen slave devices.
ATV 31 ATV 31 Advantys STB distributed I/O FTB 1CN

Independent machine with CANopen bus

Communication with a PLC


Premium XBT Magelis

Ethernet TCP/IP network ATV 71 ATV 71

The Altivar 71 drive equipped with a Controller Inside programmable card fits easily into complex architectures. Regardless of which bus or network is being used (Ethernet TCP/IP, Modbus/UniTelway, Fipio, Modbus Plus, Profibus DP, INTERBUS, etc), the PLC can communicate with the Controller Inside programmable card and the drive. The periodic variables can still be configured as required.

CANopen bus

Clock
A clock backed up by a lithium battery makes it possible to have a log of events that have occurred. When the Controller Inside programmable card is installed in the drive, the drive faults are automatically time and date-stamped without special programming.

Sensors

ATV 31

FTB 1CN

Modular machine with Ethernet TCP/IP network

Characteristics: page 36

Functions: pages 37 to 40

Catalog numbers: page 41

Wiring diagrams: page 123

Global Catalog. Refer to Statement of Scope on page 2.

35

Characteristics

Variable speed drives for asynchronous motors


Altivar 71
Option: Controller Inside programmable card

Electrical characteristics
Power supply Power consumption Current Analog inputs Voltage Maximum No-load Using logic output AI51, AI52 V A mA mA 24 c (min. 19, max. 30) 2 80 200 maximum (1) 2 current differential analog inputs 0 mA, impedance 250 20 Resolution: 10 bits Accuracy: 1% for a temperature variation of 60C Linearity: 0.2% of the maximum value Common point for all the card I/O (2) 2 current analog outputs 0 mA, impedance 500 20 Resolution: 10 bits Accuracy: 1% for a temperature variation of 60C Linearity: 0.2% of the maximum value Common point for all the card I/O (2) 10 logic inputs, 2 of which can be used for 2 counters or 4 of which can be used for 2 incremental encoders Impedance 4.4 k Maximum voltage: 30 V c Switching thresholds: State 0 if y 5 V or logic input not wired State 1 if u 11 V Common point for all the card I/O (2) Six 24 V c logic outputs, positive logic open collector type (source), compatible with level 1 PLC, standard IEC 65A-68 Maximum switching voltage: 30 V Maximum current: 200 mA Common point for all the card I/O (2) Screw, at intervals of 3.81 mm2 1.5 (AWG 16) 0.25 8 years approx.

Analog outputs

AO51, AO52

Logic inputs

LI51LI60

Logic outputs

LO51LO56

Connection of I/O Lithium battery

Type of contact Maximum capacity Tightening torque Life

mm2 Nm

Characteristics of the application program


Compiled program (saved in flash memory) Data Maximum size Maximum size Saved size (NVRAM) Size accessible by Modbus Kb 320 Kwords 64 Kwords 4 Kwords 2

Characteristics of the CANopen communication port


Structure Connector Network management Transmission speed Address (Node ID) CANopen application layer Profile PDO SDO Error check Other services Using LEDs One 9-way male SUB-D connector Master Configurable via the program: 50 Kbps, 125 Kbps, 250 Kbps, 500 Kbps or 1 Mbps 32 slaves maximum DS 301 V4.02 DSP 405 9 receive and transmit PDOs in total for each slave 2 client SDOs per slave (1 read and 1 write). Block transfer Node Guarding, producer and consumer Heartbeat Emergency, Boot-up, Sync 2 LEDs: RUN and ERROR, conforming to CIA DR303 version 1.0

Services

Diagnostics

(1) If the power consumption table does not exceed 200 mA, this card can be powered by the drive. Otherwise, an external 24 V c power supply must be used. (2) This common point is also the drive 0 V.

Presentation: page 34

Functions: pages 37 to 40

Catalog numbers: page 41

Wiring diagrams: page 123

36

Global Catalog. Refer to Statement of Scope on page 2.

Functions

Variable speed drives for asynchronous motors


Altivar 71
Option: Controller Inside programmable card

PS 1131 software workshop


The PS 1131 software workshop conforms to international standard IEC 61131-3, and includes all the functions for programming and setting up the Controller Inside programmable card. It includes the configurator for CANopen. It is designed for Microsoft Windows 98, Microsoft Windows NT 4.0, Microsoft Windows Millennium, Microsoft Windows 2000 Professional and Microsoft Windows XP operating systems. It benefits from the user-friendly interface associated with these operating systems: b Pop-up menus b Function blocks b Online help The PS 1131 software workshop is available in both English and German. The programming and debugging tools can be accessed via the application browser. This provides the user with an overview of the program and quick access to all the application components: b Program editor b Function blocks editor b Variables editor b Animation tables editor b Runtime screens editor

Modular structured programming


The PS 1131 software workshop is used to structure an application into function modules consisting of sections (program code), animation tables and runtime screens. Each program section has a name and is programmed in one of the six available languages. To protect know-how or prevent any accidental modification, each section can be write-protected or read/write-protected. Exporting/importing function modules It is possible to export all or part of the tree structure in function modules. Program structure and execution of an application The program structure is single-task. It consists of several subroutines. Exchanges with the drive are performed by a function block available in the standard library. Cycle execution can be either cyclic, or periodic. A software watchdog, which can be configured between 100 and 800 ms by the user, monitors the cycle time. A task can be synchronized with the drive main task to improve repeat accuracy in motion control applications. Cyclic execution Once each cycle ends, execution of a new cycle begins. The cycle execution must last for at least 5 ms. Periodic execution The program is executed periodically, and the period can be set by the user between 5 and 100 ms. Cycle execution must last for less than the defined period. Drive response in the event of the cycle time being exceeded can be managed by the program.

Cyclic task or start of period

Acquisition of Controller Inside programmable card inputs and CANopen PDOs Exchange of periodic data with the drive

Program processing

Updating of Controller Inside programmable card outputs and CANopen PDOs End of task

Example of cycle execution for the Controller Inside programmable card connected on a CANopen bus

Presentation: page 34

Characteristics: page 36

Catalog numbers: page 41

Wiring diagrams: page 123

Global Catalog. Refer to Statement of Scope on page 2.

37

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Option: Controller Inside programmable card

Programming languages
6 programming languages are available: b Ladder language (LD) b Structured Text language (ST) b Grafcet language (SFC) b Instruction List language (IL) b Function block diagram (FBD) b Continuous Flow Chart (CFC)

Example of Ladder language programming

Ladder Diagram (LD) A Ladder language program consists of a set of rungs executed sequentially. A rung consists of several lines. A line consists of several contacts and a coil. The language objects can be entered and displayed as symbols or tags as required. The Ladder language editor enables the immediate call of entry help functions such as access to function libraries and access to the variables editor.

Example of Structured Text language programming

Structured Text (ST) Structured Text language is a sophisticated algorithmic type language which is particularly well-suited to programming complex arithmetical functions, manipulating tables, message handling, etc. Structured Text language enables direct transcription of an analysis based on a flow chart, and is organized in statements.

Grafcet language (SFC) Grafcet language is used to describe the sequential part of the control system in a simple, graphic way. It corresponds to the Sequential Function Chart (SFC) language described in standard IEC 61131-3. Programs written in Grafcet (SFC) language consist of: b Macro-steps which are the grouping of a set of steps and transitions b Steps with which the actions to be performed can be associated b Transitions with which the conditions are associated (transition conditions) b Directed links connecting the steps and transitions
Example of Grafcet language programming

Presentation: page 34

Characteristics: page 36

Catalog numbers: page 41

Wiring diagrams: page 123

38

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Option: Controller Inside programmable card

Programming languages (continued)


Instruction List language (IL) Instruction List language can be used to write Boolean equations and use all the functions available in the language. It can be used to represent the equivalent of a ladder diagram in text form. Each instruction consists of an instruction code and a bit or word type operand. As in Ladder language, instructions are organized in sequences of instructions called statements (equivalent to a rung). Function block diagram (FBD) FBD is a graphic language. It consists of function blocks connected by a rung. The program is executed sequentially. Each block can be a logical or arithmetical expression, a call to another function block, a jump or a return instruction.
Example of Instruction List language programming

Continuous Flow Chart (CFC) Continuous Flow Chart programming is a graphic language. The rung connecting the various function blocks on the page is not necessarily sequential. The output of a function block may be looped back on its input or on the input of a block already inserted in the rung.

SETDRIVE_VEL_LFR iConsigne SetDrive_Vel_LFR

Function blocks
The PS 1131 software workshop has pre-programmed function blocks (standard library) and offers users the option of creating their own function blocks (user library). Standard library The standard library contains: b Logic functions (AND, OR, etc) b Mathematical functions (Cos, Sin, Exp, etc) b Function blocks dedicated to drives which simplify data exchanges between the drive and the Controller Inside programmable card (example: sending the speed reference) b Function blocks for managing the CANopen bus b Graphic terminal display function blocks User library Users have the option of creating their own function blocks in order to structure their applications. This is a means of protecting the know-how contained in the algorithms, as it is possible to lock access to the user function blocks program.

Example of a function block: sending the speed reference to the drive.

Presentation: page 34

Characteristics: page 36

Catalog numbers: page 41

Wiring diagrams: page 123

Global Catalog. Refer to Statement of Scope on page 2.

39

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Option: Controller Inside programmable card

Debugging
The PS 1131 software workshop offers a complete set of tools for debugging the application. Program execution for debugging The main debugging functions are: b Use of breakpoints b Step-by-step program execution b Execution of a single cycle b Direct access to the subroutines that have been called (call stack) Realtime program animation The main functions of realtime animation of the program are: b Animation of part of the program in any language b Automatic display of a variables window relating to this part of the program Animation tables Tables containing variables for the application to be monitored can be created and saved. In both these tools, in addition to animating the data, it is possible to: b Modify and force the value of data of any type b Change the display format (binary, hexadecimal, etc) Oscilloscope The PS 1131 software workshop Oscilloscope function can be used to monitor up to 20 variables in the form of curves. Runtime screens A tool integrated in the PS 1131 software workshop can be used to design and use runtime screens for the application: b Creation of screen backgrounds b Animation of graphic objects associated with variables b Display of messages b Etc Simulation The PS 1131 software workshop Simulation function can be used to test the program without having to set up the drive.

Example of runtime screen

Presentation: page 34

Characteristics: page 36

Catalog numbers: page 41

Wiring diagrams: page 123

40

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers

Variable speed drives for asynchronous motors


Altivar 71
Option: Controller Inside programmable card

Catalog numbers
Card
Description Controller Inside programmable card (1) equipped with one 9-way male SUB-D connector Catalog number VW3 A3 501 Weight kg 0.320

Connection accessories
Description CANopen connector (2) 9-way female SUB-D with line terminator that can be disabled Weight kg VW3 CAN KCDF 180T Catalog number

Connection kit for PC serial port containing various accessories including: b 1 x 3 m cable with 2 RJ 45 connectors b 1 RS 232/RS 485 converter with one 9-way female SUBD connector and one RJ45 connector

VW3 A8 106

0.350

Cables
Description CANopen cables EC/LSZH standard Length m 50 100 300 Catalog number TSX CAN CA 50 TSX CAN CA 100 TSX CAN CA 300 Weight kg

CANopen cables UL/C1 standard

50 100 300

TSX CAN CB 50 TSX CAN CB 100 TSX CAN CB 300

CANopen cable extra-flexible LSZH CANopen cables high chemical resistance

100

TSX CAN CC 100

50 100 300

TSX CAN CD 50 TSX CAN CD 100 TSX CAN CD 300

PS 1131 software workshop


Description PS 1131 software workshop supplied on CD-ROM Catalog number (3) Weight kg

(1) The Altivar 71 drive can only take one Controller Inside programmable card. Consult the summary tables of possible drive, option and accessory combinations (see pages 88 to 91). (2) On drives ATV 71HpppM3, ATV 71HD11M3X, HD15M3X,ATV 71H075N4 HD18N4, this connector can be replaced by the TSX CAN KCDF 180T connector. (3) The product catalog number is provided during the Controller Inside programmable card training course. Please consult your Regional Sales Office.

Presentation: page 34

Characteristics: page 36

Catalog numbers: page 41

Wiring diagrams: page 123

Global Catalog. Refer to Statement of Scope on page 2.

41

Presentation

Variable speed drives for asynchronous motors


Altivar 71
Communication buses and networks

XBT Magelis

Premium

Presentation
The Altivar 71 drive is designed to suit all configurations found in communicating industrial installations.
CANopen bus

It includes Modbus and CANopen communication protocols as standard. The Modbus protocol can be accessed directly by means of 2 integrated communication ports (for characteristics, see page 15): b One RJ45 Modbus terminal port 1, located on the drive front panel, for connecting: v the remote graphic display terminal v a Magelis industrial HMI terminal v the PowerSuite software workshop b One RJ45 Modbus network port 2, located on the drive control terminals. It is dedicated to control and signalling by a PLC or other type of controller. It can also be used to connect a terminal or the PowerSuite software workshop. The CANopen protocol can be accessed from the Modbus network port via the CANopen adaptor 3 (for characteristics, see page 15). In this case, terminal port 1 must be used to access the Modbus protocol. The Altivar 71 drive can also be connected to other industrial communication buses and networks using one of the communication option cards: b Ethernet TCP/IP b Modbus/Uni-Telway. This card can offer functions in addition to those of the integrated ports: Modbus ASCII and 4-wire RS 485 b Fipio b Modbus Plus b Profibus DP b DeviceNet b INTERBUS The option of powering the control part separately enables communication to be maintained (monitoring, diagnostics) even if there is no power supply to the power part. The main Altivar 58 and Altivar 58F drive communication functions are compatible with the Altivar 71 drive (1): - Connection - Communication services - Drive behaviour (profile) - Control and monitoring parameters - Standard adjustment parameters The PowerSuite software workshop can be used to port configurations from Altivar 58 and Altivar 58F drives to the Altivar 71 drive.
(1) Consult the ATV 58(F)/ATV 71 substitution guide supplied on the documentation CD-ROM.

FTM

FTM

ATV 31 ATV 71 Sensors Sensors

Example of configuration on the CANopen bus

533191

2 3

Functions: page 43

Characteristics: pages 44 to 47

Catalog numbers: pages 48 and 49

42

Global Catalog. Refer to Statement of Scope on page 2.

Functions

Variable speed drives for asynchronous motors


Altivar 71
Communication buses and networks

Functions
All the drive functions can be accessed via the network: b Controlling b Monitoring b Adjustment b Configuration When the drive is equipped with the "Controller Inside" programmable card, its variables (% MW, etc.) can be accessed via the Modbus message handling services via the integrated communication ports or the Ethernet TCP/IP communication card. The speed or torque command and reference may come from different control sources: b I/O terminals b Communication network b Controller Inside programmable card b Remote graphic display terminal The advanced functions of the Altivar 71 drive can be used to manage switching of these drive control sources according to the application requirements. It is possible to choose the assignment of the communication periodic variables using: b The network configuration software (Sycon, etc) b The Altivar 71 drive communication scanner function Regardless of the type of network (except DeviceNet), the Altivar 71 drive can be controlled: b According to the Drivecom profile (CANopen CiA DSP 402) b According to the I/O profile where control is as simple and adaptable as control via the I/O terminals The DeviceNet card supports the ODVA standard profile. Communication is monitored according to criteria specific to each protocol. However, regardless of the protocol, it is possible to configure the drive reaction to a communication fault: b Freewheel stop, stop on ramp, fast stop or braked stop b Maintain the last command received b Fallback position at a predefined speed b Ignore the fault A command from the CANopen bus is processed with the same priority as one of the drive terminal inputs. This results in excellent response times on the network port via the CANopen adaptor.

Presentation: page 42

Characteristics: pages 44 to 47

Catalog numbers: pages 48 and 49

Global Catalog. Refer to Statement of Scope on page 2.

43

Characteristics

Variable speed drives for asynchronous motors


Altivar 71
Communication buses and networks

Characteristics of the VW3 A3 310 Ethernet TCP/IP card (1)


Structure Connector Transmission speed IP addressing One RJ45 connector 10/100 Mbps, half duplex and full duplex b Manual assignment via the display terminal or the PowerSuite software workshop b BOOTP (IP address dynamic server depending on the IEEE address) b DHCP (address dynamic server depending on the Device Name) with automatic reiteration Ethernet 2 (IEEE 802.3 is not supported) LLC: IEEE 802.2 MAC: IEEE 802.3 IP (RFC791) ICMP client for supporting certain IP services such as the ping command TCP (RFC793), UDP The maximum number of connections is 8 (port 502) B20 HTTP server: simultaneous connection of 8 Internet browsers possible Server factory-configured and modifiable The memory available for the application is approximately 1 Mb The factory-configured server contains the following pages: b Altivar viewer: displays the drive status and the state of its I/O, the main measurements (speed, current, etc) b Data editor: access to the drive parameters for configuration, adjustment and signalling b Altivar chart: simplified oscilloscope function b Security: configuration of passwords to access viewing and modification b FDR Agent: configuration of the Faulty Device Replacement parameters b IO Scanner: configuration of periodic variables for controlling and monitoring the drive via the PLC, etc b Ethernet statistics: drive identification (IP addresses, version, etc) from the Ethernet transmission statistics Messaging Modbus/TCP: 8 simultaneous connections Read Holding Registers (03), 63 words maximum Read Input Registers (04), 63 words maximum Write Single Register (06) Write Multiple Registers (16), 63 words maximum Read/Write Multiple Registers (23) Read Device Identification (43) Diagnostics (08) I/O scanning service (can be inhibited): b 10 control variables which can be assigned by the PowerSuite software workshop or the standard Web server b 10 monitoring variables which can be assigned by the PowerSuite software workshop or the standard Web server b PKW indexed periodic variable The Global Data service is not supported SNMP FTP (for FDR and WEB server) Yes Can be inhibited Time out can be set between 0.560 s via the terminal, the PowerSuite software workshop or the standard Web server 5 LEDs on the card: RX (reception), TX (transmission), FLT (collision detection) IP (IP address) and 10/100 Mbps (speed) Control word received Reference received Number of frames received Number of incorrect frames Periodic variables (communication scanner) (1) For Ethernet TCP/IP network, see pages 182 to 187. (2) Please consult our specialist Ethernet TCP/IP Transparent Factory catalogue.

Physical Link

Network

Transport

Transparent Ready Class (2) services Web server

Periodic variables

Network management File transfer FDR (Faulty Device Replacement) Communication monitoring

Diagnostics

Using LEDs

Using the graphic display terminal

Presentation: page 42

Functions: page 43

Catalog numbers: pages 48 and 49

44

Global Catalog. Refer to Statement of Scope on page 2.

Characteristics (continued)

Variable speed drives for asynchronous motors


Altivar 71
Communication buses and networks

Characteristics of the VW3 A3 303 Modbus/Uni-Telway card


Structure Connector Physical interface Transmission speed One 9-way female SUB-D connector 2-wire RS 485, 4-wire RS 485 Configurable via the display terminal or the PowerSuite software workshop: b 4800 bps b 9600 bps b 19200 bps Type of polarization can be configured by switches on the card: b No polarization impedances (supplied by the wiring system, for example, in the master) b Two 4.7 k polarization resistors Via the display terminal or the PowerSuite software workshop: b Modbus RTU b Modbus ASCII b Uni-Telway 1 to 247, configurable by switches on the card. Can be inhibited Time out can be set between 0.1 s via the terminal or the PowerSuite software workshop 30 2 LEDs on the card: RUN (status) and ERR (fault) Control word received Reference received

Polarization

Selection of the protocol

Address Service Communication monitoring

Diagnostics

Using LEDs Using the graphic display terminal

Characteristics of the Modbus protocol (1)


Structure Transmission mode Format RTU, ASCII Configurable via the display terminal or the PowerSuite software workshop: In RTU mode only: b 8 bits, odd parity, 1 stop b 8 bits, no parity, 1 stop b 8 bits, even parity, 1 stop b 8 bits, no parity, 2 stop In RTU and ASCII modes: b 7 bits, even parity, 1 stop b 7 bits, odd parity, 1 stop b 7 bits, even parity, 2 stop b 7 bits, odd parity, 2 stop Service Messaging Read Holding Registers (03), 63 words maximum Read Input Registers (04), 63 words maximum Write Single Register (06) Write Multiple Registers (16), 60 words maximum Read/Write Multiple Registers (23) Read Device Identification (43) Diagnostics (08)

Characteristics of the Uni-Telway protocol (2)


Structure Service Format Messaging 8 bits, odd parity, 1 stop Read word (04h) Write word (14h) Read object (36h), 63 words maximum Write object (37h), 60 words maximum Identification (0Fh) Protocol version (30h) Mirror (FAh) Read error counters (A2h) Reset counters (A4h) (1) For the Modbus bus, see pages 192 to 195. (2) For the Uni-Telway bus, see pages 200 and 201.

Presentation: page 42

Functions: page 43

Catalog numbers: pages 48 and 49

Global Catalog. Refer to Statement of Scope on page 2.

45

Characteristics (continued)

Variable speed drives for asynchronous motors


Altivar 71
Communication buses and networks

Characteristics of the VW3 A3 311 and VW3 A3 301 Fipio cards (1)
Type of card Structure Connector Transmission speed Address Adjustment using PLC software (Unity, PL7) Profile Services Periodic variables Standard Fipio card VW3 A3 311 One 9-way male SUB-D connector 1 Mbps 1 to 62, configurable by switches on the card No Yes (limited to ATV 58 or ATV 58F compatibility parameters) Specific to the Altivar 58 or ATV 58F drive (FSD C 8P) 5 control variables 8 monitoring variables Substitution Fipio card VW3 A3 301

FED C 32 8 control variables which can be assigned by communication scanner 8 monitoring variables which can be assigned by communication scanner PKW indexed periodic variable (settings) Can be inhibited Fixed time out: 256 ms

Communication monitoring

Diagnostics

Using LEDs

4 LEDs on the card: RUN (status), ERROR (fault), COM (data exchange) and I/O (initialization) Control word received Reference received Periodic variables (communication scanner)

Using the graphic display terminal

Characteristics of the VW3 A3 302 Modbus Plus card (2)


Structure Connector Transmission speed Address Services Messaging Periodic variables One 9-way female SUB-D connector 1 Mbps 1 to 64, configurable by switches on the card Yes (Modbus) Peer Cop: 8 control variables which can be assigned by communication scanner Global data: 8 monitoring variables which can be assigned by communication scanner Can be inhibited Time out can be set between 0.160 s via the terminal or the PowerSuite software workshop. 1 LED on the card: MB+ (status) Control word received Reference received Periodic variables (communication scanner) (1) For the Fipio bus, see pages 188 to 191. (2) For the Modbus Plus network, see pages 196 to 199.

Communication monitoring

Diagnostics

Using LEDs Using the graphic display terminal

Presentation: page 42

Functions: page 43

Catalog numbers: pages 48 and 49

46

Global Catalog. Refer to Statement of Scope on page 2.

Characteristics (continued)

Variable speed drives for asynchronous motors


Altivar 71
Communication buses and networks

Characteristics of the Profibus DP card VW3 A3 307


Structure Connector Transmission speed Address Services Periodic variables One 9-way female SUB-D connector 9600 bps, 19.2 Kbps, 93.75 Kbps, 187.5 Kbps, 500 Kbps, 1.5 Mbps, 3 Mbps, 6 Mbps or 12 Mbps 1 to 126, configurable by switches on the card PPO type 5 8 control variables which can be assigned by communication scanner 8 monitoring variables which can be assigned by communication scanner PKW indexed periodic variable (settings) Can be inhibited Time out can be set via the Profibus DP network configurator 2 LEDs on the card: ST (status) and DX (data exchange) Control word received Reference received Periodic variables (communication scanner) A single gsd file supplied on the documentation CD-ROM for the whole range. It does not contain the description of the drive parameters

Communication monitoring

Diagnostics

Using LEDs Using the graphic display terminal

Description file

Characteristics of the VW3 A3 309 DeviceNet card


Structure Connector Transmission speed Address Periodic variables One removable screw connector, 5 contacts at intervals of 5.08 125 Kbps, 250 Kbps or 500 Kbps, configurable by switches on the card 1 to 63, configurable by switches on the card ODVA assemblies type 20, 21, 70 and 71 Allen-Bradley assemblies type 103, 104 and 105 Communication scanner assemblies 100 and 101 Inputs: Polled, Change of state, Cyclic Outputs: Polled No Can be inhibited Time out can be set via the DeviceNet network configurator One two-tone LED on the card: MNS (status) Control word received Reference received A single eds file supplied on the documentation CD-ROM for the whole range. It contains the description of the drive parameters

Services

Periodic exchange mode Auto Device Replacement Communication monitoring

Diagnostics

Using LEDs Using the graphic display terminal

Description file

Characteristics of the VW3 A3 304 INTERBUS card


Structure Connector Power supply Drivecom profile Services Messaging 2 connectors: One 9-way male SUB-D and one 9-way female SUB-D The card is powered by the drive. To ensure that the INTERBUS subscriber continues to operate during line supply failures to the power part, fit a separate power supply for the drive control part. 21 PCP: b Read: read a parameter b Write: write a parameter b Initiate: initialize the communication relationship b Abort: abort the communication relationship b Status: drive communication status b Get-OV: read an object description b Identify: identification of the card 2 control variables which can be assigned by communication scanner 2 monitoring variables which can be assigned by communication scanner Can be inhibited Fixed time out: 640 ms 5 LEDs on the card: U (power supply), RC (bus input), Rd (bus output), BA (periodic data) and TR (messaging) Control word received Reference received

Periodic variables Communication monitoring

Diagnostics

Using LEDs Using the graphic display terminal

Presentation: page 42

Functions: page 43

Catalog numbers: pages 48 and 49

Global Catalog. Refer to Statement of Scope on page 2.

47

Catalog numbers

Variable speed drives for asynchronous motors


Altivar 71
Communication buses and networks

Communication cards (1)


Description
533192

Use To be connected on a Hub or Switch using a 490 NTW 000 pp cable. See pages 186 and 187 To be connected on TSX SCA 62 subscriber socket using the VW3 A8 306 2 cable. See pages 193 and 131

Catalog number VW3 A3 310

Ethernet Class B20 (2)

Weight kg 0.300

Modbus/ Uni-Telway

VW3 A3 303

0.300

VW3 A3 311 Standard Fipio To be connected using a TSX FP ACC 12 connector with a TSX FP CCpp extension cable or a TSX FP CApp drop cable. This card should be used for new installations. It is also used to replace an ATV 58 or ATV 58F drive equipped with a VW3 A58 311 card by an ATV 71 drive. To replace an ATV 58 or ATV 58F drive equipped with a VW3 58 301 card by an ATV 71 drive, use the VW3 A3 301 card (substitution). See pages 190 and 191 VW3 A3 311 Substitution Fipio This card is also used to replace an ATV 58 or VW3 A3 301 ATV 58F equipped with a VW3 A58 301 card by an ATV 71. To replace an ATV 58 or ATV 58F drive equipped with a VW3 A58 311 card by an ATV 71 drive, use the VW3 A3 311 card (standard). See pages 190 and 191 To be connected to the 990 NAD 230 00 IP 20 VW3 A3 302 Modbus Plus tap using a 990 NAD 219p0 cable. See pages 198 and 199

0.300

0.300

533193

Modbus Plus

0.300

TSX FP ACC12 Profibus DP To be connected using a 490 NAD 911pp VW3 A3 307 connector to Profibus cable TSX PBS CAp00 (3) 0.300

DeviceNet
533194

The card is equipped with removable screw terminals. To be connected using cables for installation remote bus, reference 170 MCI ppp00 (3)

VW3 A3 309

0.300

INTERBUS

VW3 A3 304

0.300

490 NAD 911 03 (1) The Altivar 71 drive can only take one communication card. Consult the summary tables of possible drive, option and accessory combinations (see pages 88 to 91). (2) Please consult our specialist Ethernet TCP/IP Transparent Factory catalogue. (3) Please consult our specialist "Modicon Premium Automation Platform - Unity & PL7" catalogue.

Presentation: page 42

Functions: page 43

Characteristics: pages 44 to 47

48

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers (continued)

Variable speed drives for asynchronous motors


Altivar 71
Communication buses and networks

Connection accessories
Description
Premium (1)
533195

Length m

Unit catalog number

Weight kg 0.500

Modbus bus
Modbus splitter block 1 10 RJ45 connectors and 1 screw terminal block Cables for Modbus bus equipped 2 with 2 RJ45 connectors LU9 GC3

Modbus bus

3 4

0.3 1

VW3 A8 306 R03 VW3 A8 306 R10 VW3 A8 306 R30

0.025 0.060 0.130

4 2 2 3 3
Modbus T-junction boxes (with integrated cable) 3

(2)

0.3 1

VW3 A8 306 TF03 VW3 A8 306 TF10

ATV 71

Example of Modbus diagram, connections via splitter blocks and RJ45 connectors

Line terminator For RJ45 connector (3)

VW3 A8 306 RC

0.010

Description
Premium (1)
533196

Length m

Catalog number

Weight kg

CANopen bus
1 CANopen adaptor for mounting on the RJ45 socket in the drive control terminals. The adaptor provides a 9-way male SUB-D connector conforming to the CANopen standard (CIA DRP 303-1).
ATV 71

VW3 CAN A71

(2)
CANopen bus

1 2 3
Example of CANopen diagram

CANopen connector (4) 9-way female SUB-D with line contactor (can be disabled). 180 cable outlet CAN-H, CAN-L, CAN-GND connection

VW3 CAN KCDF 180T

3 CANopen cables (1) Standard environments, fixed installation, LSZH (Low Smoke, Zero Halogen)

50 100 300

TSX CAN CA 50 TSX CAN CA 100 TSX CAN CA 300 TSX CAN CB 50 TSX CAN CB 100 TSX CAN CB 300 TSX CAN CD 50 TSX CAN CD 100 TSX CAN CD 300

533196

CANopen cables (1) Standard environments, fixed installation, UL certification, flame retardant (IEC 60332-2) VW3 CAN A71

50 100 300

3 CANopen cables (1) Harsh environments, mobile installation, LSZH (Low Smoke, Zero Halogen), resistant to chemicals and solder splashes

50 100 300

(1) Please consult our specialist "Modicon Premium Automation Platform - Unity & PL7" and "Modicon TSX Micro Automation Platform - PL7" catalogues. (2) Cable depending on the type of controller or PLC. (3) Sold in lots of 2. (4) On drives ATV 71HpppM3, ATV 71HD11M3X, HD15M3X,ATV 71H075N4 HD18N4, this connector can be replaced by the TSX CAN KCDF 180T connector.

Presentation: page 42

Functions: pages 43

Characteristics: pages 44 to 47

Global Catalog. Refer to Statement of Scope on page 2.

49

Presentation, characteristics

Variable speed drives for asynchronous motors


Altivar 71
Options: resistance braking units

Presentation
ATV 71HpppM3, ATV 71HpppM3X and ATV 71H075N4HC16N4 drives have a built-in dynamic brake transistor. For ATV 71HC20N4HC50N4 drives, a braking unit must be used. It is controlled by the drive: b For ATV 71HC20N4HC28N4 drives, the braking unit is mounted directly on the left-hand side of the drive, see dimensions page 93. b For ATV 71HC40N4, HC50N4 drives, the braking unit is an external module, see dimensions page 100. Resistance braking enables the Altivar 71 drive to operate while braking to a standstill or during "generator" operation, by dissipating the energy in the braking resistor. Applications High-inertia machines, machines with cycles and fast cycles, high-power machines performing vertical movements.

Characteristics
Operation Storage Degree of protection of enclosure Degree of pollution Relative humidity Maximum operating altitude Vibration resistance Nominal line supply voltage and drive supply voltage (rms value) Engage threshold Maximum DC bus voltage Maximum braking power on 400 V z supply Percentage of conduction time at constant power at 785 V c Cycle time Maximum continuous power Braking power on a vertical movement (values given for a cycle time of 240 s)
250 kW 110 s 420 kW 10 s 0 kW 120 s 440 kW 110 s

Type of braking unit Ambient air temperature around the device

C C

m V V V kW

VW3 A7 101 - 10+ 50 - 25+ 70 IP 20 2 according to standard EN 50178 Class 3K3 without condensation 2000 0.2 gn a 380 - 15%480 + 10% c 785 1% 850 420 5% at 420 kW 15% at 320 kW 50% at 250 kW 240 200

VW3 A7 102

785 V c (1)

750 5% at 750 kW 15% at 550 kW 50% at 440 kW

s kW

400

750 kW 0 kW 120 s

10 s

Thermal protection Forced ventilation Mounting Minimum resistance value to be associated with the braking unit m3/h

Integrated, via thermal probe 100 Vertical 1.05 0.7 600

(1) Braking unit engage threshold

Catalog numbers: page 51

Selection: pages 56 to 61

Dimensions: pages 93 to 100

Wiring diagrams: pages 120 and 126

50

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers

Variable speed drives for asynchronous motors


Altivar 71
Options: resistance braking units

Braking units
Supply voltage: 380480 V 50/60 Hz
For drives Power Continuous Max. kW ATV 71HC20N4 200 HC28N4 ATV 71HC31N4 400 HC50N4 kW 420 Loss Continuous power W 550 Cable (drivebraking unit) CrossMax. section length mm2 m Internal connections 2 x 150 1 Cable (braking unit-resistors) CrossMax. section length mm2 m 2 x 95 50 Catalog number Weight

VW3 A7 101

kg 30.000

750

750

2 x 150

50

VW3 A7 102

80.000

Note: To increase the braking power, several resistors can be mounted in parallel on the same braking unit. In this case, do not forget to take account of the minimum resistance value on each unit.

Presentation: page 50

Characteristics: page 50

Selection: pages 56 to 61

Dimensions: pages 93 to 100

Wiring diagrams: pages 120 and 126

Global Catalog. Refer to Statement of Scope on page 2.

51

Presentation, characteristics

Variable speed drives for asynchronous motors


Altivar 71
Options: braking resistors

Presentation
The braking resistor enables the Altivar 71 drive to operate while braking to a standstill or during slowdown braking, by dissipating the braking energy. It enables maximum transient braking torque. The resistors are designed to be mounted on the outside of the enclosure, but should not inhibit natural cooling. Air inlets and outlets must not be obstructed in any way. The air must be free of dust, corrosive gas and condensation. Applications Inertia machines, machines with cycles.

General characteristics
Type of braking resistor Ambient air temperature around the device Operation Storage Degree of protection of enclosure Thermal protection Temperature controlled switch (1) Tripping temperature Max. voltage - max. current Min. voltage - min. current Maximum contact resistance C C C VW3 A7 701709 0+ 50 - 25+ 70 IP 20 Via temperature controlled switch or via the drive 120 a 250 V - 1 A c 24 V - 0.1 A 60 IP 23 Via thermal overload relay VW3 A7 710718

Operating factor for the dynamic brake transistors ATV 71HpppM3, ATV 71HpppM3X, ATV 71H075N4HD75N4 ATV 71HD90N4HC16N4

The internal circuits of Altivar 71 drives rated 160 kW or less have a built-in dynamic brake transistor. The dynamic brake transistor is sized so that it can tolerate: b the nominal motor power continuously b 150% of the nominal motor power for 60 s The dynamic brake transistor is sized so that it can tolerate: b 75% of the nominal motor power continuously b 150% of the nominal motor power for 10 s

Connection characteristics
Type of terminal Maximum connection capacity VW3 A7 701703 VW3 A7 704709 VW3 A7 710718 Drive connection 4 mm2 (AWG 28) Bar connection, M6 Bar connection, M10 Temperature-controlled switch 1.5 mm2 (AWG 16) 2.5 mm2 (AWG 14)

Minimum ohmic value of the resistors to be associated with the Altivar 71 drive, at 20C (2)
Type of ATV 71H drive Minimum value Type of ATV 71H drive Minimum value Type of ATV 71H drive Minimum value Type of ATV 71H drive Minimum value 037M3, 075M3 44 D11M3X, D15M3X 3 075N4 U22N4 56 D37N4 6.7 U15M3 33 D18M3X 4 U30N4, U40N4 34 D45N4, D55N4 5 U22M3, U30M3 22 D22M3X, D30M3X 3.3 U55N4 23 D75N4 3.3 U40M3 16 D37M3X D55M3X 1.7 U75N4 19 D90N4 2.5 U55M3 11 D75M3X 1.3 D11N4 12 C11N4 C16N4 1.9 D15N4, D18N4 7 C20N4 C28N4 0.95 D22N4, D30N4 13.3 C31N4 C50N4 0.63 U75M3 8

(1) The switch should be connected in the sequence (for use in signalling, or in line contactor control). (2) In an environment where the temperature is below 20C, make sure that the minimum ohmic value recommended in the table is observed.

Catalog numbers: page 53

Selection: pages 56 to 61

Dimensions: pages 101 and 102

Wiring diagrams: page 120

52

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers

Variable speed drives for asynchronous motors


Altivar 71
Options: braking resistors

Braking resistors
For drives Ohmic value at 20C 100 60 28 15 10 8 5 4 2.5 1.8 1.4 Average power available at 50C (1) kW 0.05 0.1 0.2 1 1 1 1 1 1 15.3 20.9 Catalog number Weight kg VW3 A7 701 VW3 A7 702 VW3 A7 703 VW3 A7 704 VW3 A7 705 VW3 A7 706 VW3 A7 707 VW3 A7 708 VW3 A7 709 VW3 A7 713 VW3 A7 714 1.900 2.400 3.500 11.000 11.000 11.000 11.000 11.000 11.000 50.000 63.000

Supply voltage: 200240 V 50/60 Hz


ATV 71H037M3, H075M3 ATV 71HU15M3, HU22M3 ATV 71HU30M3, HU40M3 ATV 71HU55M3, HU75M3 ATV 71HD11M3X ATV 71HD15M3X ATV 71HD18M3X, HD22M3X ATV 71HD30M3X ATV 71HD37M3X, HD45M3X ATV 71HD55M3X ATV 71HD75M3X

Supply voltage: 380480 V 50/60 Hz


ATV 71H075N4HU40N4 ATV 71HU55N4, HU75N4 ATV 71HD11N4, HD15N4 ATV 71HD18N4HD30N4 ATV 71HD37N4 ATV 71HD45N4HD75N4 ATV 71HD90N4 ATV 71HC11N4, HC13N4 ATV 71HC16N4 ATV 71HC20N4 ATV 71HC25N4, HC28N4 ATV 71HC31N4, HC40N4 ATV 71HC50N4 100 60 28 15 10 5 2.75 2.1 2.1 1.05 1.05 0.7 0.7 0.05 0.1 0.2 1 1 1 25 37 44 56 75 112 150 VW3 A7 701 VW3 A7 702 VW3 A7 703 VW3 A7 704 VW3 A7 705 VW3 A7 707 VW3 A7 710 VW3 A7 711 VW3 A7 712 VW3 A7 715 VW3 A7 716 VW3 A7 717 VW3 A7 718 1.900 2.400 3.500 11.000 11.000 11.000 80.000 86.000 104.000 136.000 172.000 266.000 350.000

(1) Operating factor for resistors: The value of the average power that can be dissipated at 50C from the resistor into the casing is determined for an operating factor during braking that corresponds to the majority of normal applications. For VW3 A7 701709: - 2 s braking with 0.6 Tn braking torque for a 40 s cycle - 0.8 s braking with 1.5 Tn braking torque for a 40 s cycle For VW3 A7 710718: - 10 s braking with 2 Tn braking torque for a 30 s cycle

Presentation: page 52

Characteristics: page 52

Selection: pages 56 to 61

Dimensions: pages 101 and 102

Wiring diagrams: page 120

Global Catalog. Refer to Statement of Scope on page 2.

53

Presentation, characteristics

Variable speed drives for asynchronous motors


Altivar 71
Options: hoist resistors

Presentation
The hoist resistor is a braking resistor which enables the Altivar 71 drive to operate while braking to a standstill or during slowdown braking, by dissipating the braking energy. The resistors are designed to be mounted on the outside of the enclosure, but should not inhibit natural cooling. Air inlets and outlets must not be obstructed in any way. The air must be free of dust, corrosive gas and condensation. They enable maximum transient braking torque. Applications Machines performing vertical movements, machines with fast cycles, high-inertia machines.

General characteristics
Type of hoist resistor Ambient air temperature around the device Operation Storage Degree of protection of enclosure Thermal protection Operating factor for the dynamic brake transistors ATV 71HpppM3, ATV 71HpppM3X, ATV 71H075N4HD75N4 ATV 71HD90N4HC50N4 (1) C C VW3 A7 801 0+ 50 - 25+ 75 IP 23 if horizontal mounting IP 23 IP 20 in other cases Via thermal overload relay The internal circuits of Altivar 71 drives rated 160 kW or less have a built-in dynamic brake transistor. The dynamic brake transistor is sized so that it can tolerate: b the nominal motor power continuously b 150% of the nominal motor power for 60 s The dynamic brake transistor is sized so that it can operate on a 240 s cycle at: b 88% of the nominal motor power for 50% of the cycle time b 150% of the nominal motor power for 5% of the cycle Bar connection, M6 Bar connection, M10 VW3 A7 802A7 808 VW3 A7 809A7 817

- 25+ 65

Connection characteristics
Maximum connection capacity VW3 A7 801 VW3 A7 802817

Minimum ohmic value of the resistors to be associated with the Altivar 71 drive, at 20C (2)
Type of ATV 71H drive Minimum value Type of ATV 71H drive Minimum value Type of ATV 71H drive Minimum value Type of ATV 71H drive Minimum value 037M3, 075M3 44 D11M3X, D15M3X 3 075N4 U22N4 56 D37N4 6.7 U15M3 33 D18M3X 4 U30N4, U40N4 34 D45N4, D55N4 5 U22M3, U30M3 22 D22M3X, D30M3X 3.3 U55N4 23 D75N4 3.3 U40M3 16 D37M3X D55M3X 1.7 U75N4 19 D90N4 2.5 U55M3 11 D75M3X 1.3 D11N4 12 C11N4 C16N4 1.9 D15N4, D18N4 7 C20N4 C28N4 0.95 D22N4, D30N4 13.3 C31N4 C50N4 0.63 U75M3 8

(1) For ATV 71HC20N4HC50N4 drives, a braking unit must be used, see page 50. (2) In an environment where the temperature is below 20C, make sure that the minimum ohmic value recommended in the table is observed.

Catalog numbers: page 55

Selection: pages 56 to 61

Dimensions: page 103

Wiring diagrams: page 120

54

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers

Variable speed drives for asynchronous motors


Altivar 71
Options: hoist resistors

Hoist resistors
For drives Ohmic value at 20C 100 60 24.5 14 8.1 4.2 3.5 1.85 1.8 1.4 Average power available at 50C (1) kW 1.6 5.6 9.8 22.4 44 62 19.5 27.4 30.6 44 Catalog number Weight kg VW3 A7 801 VW3 A7 802 VW3 A7 803 VW3 A7 804 VW3 A7 805 VW3 A7 806 VW3 A7 807 VW3 A7 808 VW3 A7 809 VW3 A7 810 6.000 21.000 28.000 54.000 92.000 126.000 51.000 94.000 103.000 119.000

Supply voltage: 200240 V 50/60 Hz


ATV 71H037M3, H075M3 ATV 71HU15M3 ATV 71HU22M3HU40M3 ATV 71HU55M3, HU75M3 ATV 71HD11M3X, HD15M3X ATV 71HD18M3X ATV 71HD22M3X, HD30M3X ATV 71HD37M3X, HD45M3X ATV 71HD55M3X ATV 71HD75M3X

Supply voltage: 380480 V 50/60 Hz


ATV 71H075N4HU22N4 ATV 71HU30N4HU55N4 ATV 71HU75N4, HD11N4 ATV 71HD15N4HD30N4 ATV 71HD37N4HD55N4 ATV 71HD75N4 ATV 71HD90N4 ATV 71HC11N4, HC13N4 ATV 71HC16N4 ATV 71HC20N4 ATV 71HC25N4, HC28N4 ATV 71HC31N4, HC40N4 ATV 71HC50N4 100 60 24.5 14 8.1 4.2 2.75 2.1 2.1 1.05 1.05 0.7 0.7 1.6 5.6 9.8 22.4 44 62 56 75 112 112 150 225 330 VW3 A7 801 VW3 A7 802 VW3 A7 803 VW3 A7 804 VW3 A7 805 VW3 A7 806 VW3 A7 811 VW3 A7 812 VW3 A7 813 VW3 A7 814 VW3 A7 815 VW3 A7 816 VW3 A7 817 6.000 21.000 28.000 54.000 92.000 126.000 130.000 181.000 250.000 280.000 362.000 543.000 642.000

(1)Operating factor for hoist resistors: the value of the average power that can be dissipated at 50C from the resistor is determined by an operating factor during braking. For VW3 A7 801808: - 100 s braking with 1 Tn braking torque for a 200 s cycle - 20 s braking with 1.6 Tn braking torque for a 200 s cycle For VW3 A7 809817: - 110 s braking with 1.25 Tn braking torque for a 240 s cycle - 10 s braking with 2 Tn braking torque for a 240 s cycle

Presentation: page 54

Characteristics: page 54

Selection: pages 56 to 61

Dimensions: page 103

Wiring diagrams: page 120

Global Catalog. Refer to Statement of Scope on page 2.

55

Selection

Variable speed drives for asynchronous motors


Altivar 71
Options: braking units and resistors

Determining the braking unit and resistor


Calculating the various braking powers makes it possible to determine the braking unit and the braking resistor. Presentation of the two main types of operation: A and B A The braking power during deceleration is characterized by a peak power P b obtained at the start of deceleration, which decreases to 0 in proportion with the speed. Example: Stopping centrifuges, translational movement, change of direction, etc
n1 n2 Tl Tb Pb Pb tb Motor speed Motor speed during deceleration Load torque Braking torque Peak braking power Average braking power during tb Braking time [rpm] [rpm] [Nm] [Nm] [W] [W] [s]
T

B Braking power at constant speed n2. Example: Vertical downward movement, motor/generator test bench, gravity conveyors, etc.

n n1 0
Tl tb Tb

n +n 1 0
tb tb

-n

Tl

t
Pbraking tb Pb Pb Pb Pbraking

t t

Note: Both these types of operation can be combined. Type A operation Calculating the braking time from the inertia J t b = ----------------Tb + Tr 2 n = ---------------60 J ( n1 n2 ) T b = -----------------------------------9.55 t b Tb n1 P b = -----------------9.55 Pb P b = ----2

Tb J n1 n2 tb Pb Pb Tr

Motor braking torque Total inertia applied to the motor Motor speed ahead of gearbox Motor speed after gearbox Braking time Peak braking power Average braking power during time tb Resistive torque

[Nm] [kgm2] [rpm] [rpm] [s] [W] [W] [Nm]

Machine Motor Gearbox

n1

n2

J = Jmotor +Japplied

i=

n1 n2

Japplied

Jmachine
i
2

Presentation: page 54

Characteristics: page 54

Catalog numbers: pages 51 and 53

Dimensions: pages 93 to 103

Wiring diagrams: page 120

56

Global Catalog. Refer to Statement of Scope on page 2.

Selection (continued)

Variable speed drives for asynchronous motors


Altivar 71
Options: braking units and resistors

Operating type B
1 Braking power of a load moving horizontally with constant deceleration (eg.: carriage) W m v tb Pb Pb Tb n g a v J tb Kinetic energy Weight Speed Braking time Peak braking power Average braking power during time tb Braking torque Motor speed Acceleration Deceleration Linear downward speed Moment of inertia Angular speed Downward stopping time [Joule] [kg] [m/s] [s] [W] [W] [Nm] [rpm]

m v W = ----------------2

Pb = W ---tb

Pb = Pb 2

2 Braking power for an active load (eg.: test bench)

Tb n P b = ---------------9.55

9.81 m/s2 [m/s2] 3 Braking power for a downward vertical movement [m/s] 2 [kgms2] J Pb = m g v P b = m ( g + a ) v + --------------[rad/s]

tb

2 n = ---------------60

[s]

All the braking power calculations are only true if it is assumed that there are no losses (= 1) and that there is no resistive torque. To be even more precise, the following must be considered: b the losses and the resistive torque of the system, which reduce the necessary braking power b the driving torque (the wind, for example) which increases the braking power. The required braking power is calculated as follows:
P bR P bR t o t a l Pload d r i v e m e c m o t Maximum actual braking power Continuous actual braking power [W] [W]
2 P bR = ( P b P load ) total

Total efficiency Braking power connected with the resistive or [W] driving torque (not taken into account in the calculation). Pload can be positive or negative. Drive efficiency = 0.98 Mechanical efficiency Motor efficiency

P bR = ( P b P load ) total

total = mec mot 0.98

Udc

Braking unit engage threshold

[V]

For braking, the value of the braking resistor is selected to match the required power and the braking cycle. In general:
2 U dc P bR = ------------- R = U dc ------------ R P bR 2

T P b0 t0 P b1 t1 Pb P b2 t2 Pcontinuous

Cycle time Upward braking power, therefore zero Rise time Average braking power during downward movement Downward movement time Peak braking power Standstill braking time

[s] [W] [s] [W] [1] [W] [s] [W]

Continuous power is obtained by taking the operating cycle into account.


^ Pb _ Pb1 _ Pb0 t0
tc

_ Pb2

Average power during braking to a standstill [W]

P b0 t 0 + P b1 t 1 + P b2 t 2 = --------------------------------------------------------------------------T

t1

t2

The braking unit is selected taking the following into account: b the continuous power P b1 b the average braking power during downward movement P b2 b the peak power P b Depending on these elements, select the braking unit according to the characteristics on page 50. The braking resistor is selected taking account of the same elements listed above but with the addition of a check to ensure that the resistance value will allow the peak
2 U dc power to be exceeded R = ------------- . Pb

Note: The resistance value must always be greater than or equal to the values given in the tables on pages 52 and 54.
Presentation: page 54 Characteristics: page 54 Catalog numbers: pages 51 and 53 Dimensions: pages 93 to 103 Wiring diagrams: page 120

Global Catalog. Refer to Statement of Scope on page 2.

57

Selection (continued)

Variable speed drives for asynchronous motors


Altivar 71
Characteristics curves for resistors

Example of using characteristics curves


VW3 A7 710 (P continuous = 25 kW) for 2.75 at 20C
Example of using curves: Point A For a 200 s cycle, the resistance of 2.75 accepts an overload of 7 x 25 kW (continuous power) for 24 s, ie. braking 175 kW every 200 s. Point B For a 120 s cycle, the resistance of 2.75 accepts an overload of 5 x 25 kW (continuous power) for 20 s, ie. braking 125 kW every 120 s. Point C For a 60 s cycle, the resistance of 2.75 accepts an overload of 5 x 25 kW (continuous power) for 10 s, ie. braking 125 kW every 60 s.
Coef. Pmax. Pav.

30

25

20

15

10 7 5

A C B

0 0 25 50 75

Braking resistors
VW3 A7 701 (P continuous = 0.05 kW)
Coef. Pmax. Pav.

VW3 A7 702 (P continuous = 0.1 kW)


Coef. Pmax. Pav.

50 40 30 20 10 2 0 0

50 40 30 20 10 2 0 0

10

15

20 t (s)

10

15

20 t (s)

VW3 A7 703 (P continuous = 0.2 kW)


Coef. Pmax. Pav.

VW3 A7 704709 (P continuous = 1 kW)


Coef. Pmax. Pav.

50 40 30 20 10 2 0 0

50 40 30 20 10 2 0 0

10

15

20 t (s)

10

15

20 t (s)

P max/P av (40 s cycle) P max/P av (60 s cycle) P max/P av (120 s cycle) P max/P av (200 s cycle)

Presentation: page 54

Characteristics: page 54

Catalog numbers: page 53

Dimensions: pages 101 and 102

Wiring diagrams: page 120

58

Global Catalog. Refer to Statement of Scope on page 2.

Selection (continued)

Variable speed drives for asynchronous motors


Altivar 71
Characteristics curves for resistors

Braking resistors (continued)


VW3 A7 710 (P continuous = 25 kW)
Coef. Pmax. Pav.

VW3 A7 711 (P continuous = 37 kW)


Coef. Pmax. Pav.

50 45 40 35 30 25 20 15 10 5 0
0 25 50 75 100 125 150 175 200 t (s)

30 25 20 15 10 5 0 0 25 50 75 100 125 150 175 200 t (s)

VW3 A7 712 (P continuous = 44 kW)


Coef. Pmax. Pav.

VW3 A7 713 (P continuous = 15.3 kW)


Coef. Pmax. Pav.

35 30 25 20 15 10 5 0 0 25 50 75 100 125 150 175 200 t (s)

50 45 40 35 30 25 20 15 10 5 0 0

25

50

75

100

125

150

175

200 t (s)

VW3 A7 714 (P continuous = 20.9 kW)


Coef. Pmax. Pav.

VW3 A7 715 (P continuous = 56 kW)


Coef. Pmax. Pav.

50 45 40 35 30 25 20 15 10 5 0 0 25 50 75 100 125 150 175 200 t (s)

45 40 35 30 25 20 15 10 5 0 0 25 50 75 100 125 150 175 200 t (s)

P max/P av (60 s cycle) P max/P av (120 s cycle) P max/P av (200 s cycle)

Presentation: page 54

Characteristics: page 54

Catalog numbers: page 53

Dimensions: pages 101 and 102

Wiring diagrams: page 120

Global Catalog. Refer to Statement of Scope on page 2.

59

Selection (continued)

Variable speed drives for asynchronous motors


Altivar 71
Characteristics curves for resistors

Braking resistors (continued)


VW3 A7 716 (P continuous = 75 kW)
Coef. Pmax. Pav.

VW3 A7 717 (P continuous = 112 kW)


Coef. Pmax. Pav.

45 40 35 30 25 20 15 10 5 0 0

40 35 30 25 20 15 10 5 0

25

50

75

100

125

150

175

200 t (s)

25

50

75

100

125

150

175

200 t (s)

VW3 A7 718 (P continuous = 150 kW)


Coef. Pmax. Pav.

45 40 35 30 25 20 15 10 5 0 0

25

50

75

100

125

150

175

200 t (s)

P max/P av (60 s cycle) P max/P av (120 s cycle) P max/P av (200 s cycle)

Presentation: page 54

Characteristics: page 54

Catalog numbers: page 53

Dimensions: pages 101 and 102

Wiring diagrams: page 120

60

Global Catalog. Refer to Statement of Scope on page 2.

Selection (continued)

Variable speed drives for asynchronous motors


Altivar 71
Characteristics curves for resistors

Hoist resistors
VW3 A7 801 (P continuous = 1.6 kW)
Coef. Pmax. Pav.

VW3 A7 802 (P continuous = 5.6 kW)


Coef. Pmax. Pav.

25 20 15 10 5 1 0 0 25 50 75 100 125 150 175 200 t (s)

14 12 10 8 6 4 2 1 0 0 25 50 75 100 125 150 175 200 t (s)

VW3 A7 803 (P continuous = 9.8 kW)


Coef. Pmax. Pav.

VW3 A7 804 (P continuous = 22.4 kW)


Coef. Pmax. Pav.

30 25 20 15 10 5 1 0

40 35 30 25 20 15 10 5 1 0

25

50

75

100

125

150

175

200 t (s)

25

50

75

100

125

150

175

200 t (s)

VW3 A7 805 (P continuous = 44 kW)


Coef. Pmax. Pav.

VW3 A7 806 (P continuous = 62 kW)


Coef. Pmax. Pav.

25 20 15

30 25 20 15

10 5 1 0

10 5 1 0 0 25 50 75 100 125 150 175 200 t (s)

25

50

75

100

125

150

175

200 t (s)

P max/P av (60 s cycle) P max/P av (120 s cycle) P max/P av (200 s cycle)

Presentation: page 54

Characteristics: page 54

Catalog numbers: page 55

Dimensions: page 103

Wiring diagrams: page 120

Global Catalog. Refer to Statement of Scope on page 2.

61

Selection (continued)

Variable speed drives for asynchronous motors


Altivar 71
Characteristics curves for resistors

Hoist resistors (continued)


VW3 A7 807 (P continuous = 19.5 kW)
Coef. Pmax. Pav.

VW3 A7 808 (P continuous = 27.4 kW)


Coef. Pmax. Pav.

40 35 30 25 20 15 10 5 1 0

60 50 40 30 20 10 1

25

50

75

100

125

150

175

200 t (s)

25

50

75

100

125

150

175

200 t (s)

VW3 A7 809 (P continuous = 30.6 kW)


Coef. Pmax. Pav.

VW3 A7 810 (P continuous = 44 kW)


Coef. Pmax. Pav.

50 45 40 35 30 25 20 15 10 5 0 0

45 40 35 30 25 20 15 10 5 25 50 75 100 125 150 175 200 t (s) 0 0 25 50 75 100 125 150 175 200 t (s)

VW3 A7 811 (P continuous = 56 kW)


Coef. Pmax. Pav.

VW3 A7 812 (P continuous = 75 kW)


Coef. Pmax. Pav.

40 35 30 25 20 15 10 5 0 0

45 40 35 30 25 20 15 10 5 25 50 75 100 125 150 175 200 t (s) 0 0 25 50 75 100 125 150 175 200 t (s)

P max/P av (60 s cycle) P max/P av (120 s cycle) P max/P av (200 s cycle)

Presentation: page 54

Characteristics: page 54

Catalog numbers: page 55

Dimensions: page 103

Wiring diagrams: page 120

62

Global Catalog. Refer to Statement of Scope on page 2.

Selection (continued)

Variable speed drives for asynchronous motors


Altivar 71
Characteristics curves for resistors

Hoist resistors (continued)


VW3 A7 813 (P continuous = 112 kW)
Coef. Pmax. Pav.

VW3 A7 814 (P continuous = 112 kW)


Coef. Pmax. Pav.

40 35 30 25 20 15 10 5 0 0 25 50 75 100 125 150 175 200 t (s)

45 40 35 30 25 20 15 10 5 0 0 25 50 75 100 125 150 175 200 t (s)

VW3 A7 815 (P continuous = 150 kW)


Coef. Pmax. Pav.

VW3 A7 816 (P continuous = 225 kW)


Coef. Pmax. Pav.

45 40 35 30 25 20 15 10 5 0 0

45 40 35 30 25 20 15 10 5 0 0 25 50 75 100 125 150 175 200 t (s)

25

50

75

100

125

150

175

200 t (s)

VW3 A7 817 (P continuous = 330 kW)


Coef. Pmax. Pav.

40 35 30 25 20 15 10 5 0 0 25 50 75 100 125 150 175 200 t (s)

P max/P av (60 s cycle) P max/P av (120 s cycle) P max/P av (200 s cycle)

Presentation: page 54

Characteristics: page 54

Catalog numbers: page 55

Dimensions: page 103

Wiring diagrams: page 120

Global Catalog. Refer to Statement of Scope on page 2.

63

Presentation, applications, characteristics

Variable speed drives for asynchronous motors


Altivar 71
Options: network braking units

Presentation
L1 L2 L3

The network braking unit can be used to restore the following to the line supply: b the energy from the motor b the energy from the motors controlled by several drives connected on the same DC bus

PA/+
Altivar 71

Network braking unit

PC/

Applications Braking on a driving load: b vertical movements b escalators b etc

General characteristics
Degree of protection Maximum relative humidity Ambient air temperature around the device Maximum operating altitude Operation Storage C C m IP 20 Class F humidity without condensation 585% 5+ 40 without derating Up to 55C with current derating of 3% per C above 40C - 25+ 55 1000 without derating 10004000 derating the current by 5% per additional 1000 m

Electrical characteristics
Type of module Supply voltage Nominal voltage 10% Operating frequency Overload capacity Efficiency Power factor Fundamental frequency component V V Hz A VW3 A7 201212 a 400 a 380415 4060 10 % 1.2 x maximum current (Irms) 97% (3% of thermal losses) 1 0.70.95 VW3 A7 231241 a 460 a 440480

Connection characteristics
Maximum connection capacity VW3 A7 201 VW3 A7 202205, VW3 A7 231, 232 VW3 A7 206209, VW3 A7 233238 VW3 A7 210212, VW3 A7 239241 25 mm2, connected on a bar, M5 35 mm2, connected on a bar, M6 95 mm2, connected on a bar, M8 150 mm2, connected on a bar, M10

Catalog numbers: page 65

Selection: pages 66 and 67

Dimensions: pages 104 and 105

Wiring diagrams: page 125

64

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers

Variable speed drives for asynchronous motors


Altivar 71
Options: network braking units
Line voltage: a 400 V
Maximum current Irms a c A A 11 13 20 32 48 65 102 130 195 231 289 360 500 24 38 58 78 123 157 236 279 350 433 600 Continuous braking power kW 7 13 11 21.5 26 32 38 38 86 120 135 200 CL fuses a A 20 30 50 80 100 160 200 315 350 400 500 630 a V 660 690 690 690 690 660 660 660 660 1000 1000 1000 Catalog number Weight

VW3 A7 201 VW3 A7 202 VW3 A7 203 VW3 A7 204 VW3 A7 205 VW3 A7 206 VW3 A7 207 VW3 A7 208 VW3 A7 209 VW3 A7 210 VW3 A7 211 VW3 A7 212

kg 20.000 25.000 26.000 30.000 32.000 43.000 48.000 52.000 90.000 100.000 115.000 125.000

Line voltage: a 460 V


Maximum current Irms a c A A 28 33 41 57 88 113 138 157 176 201 289 500 50 69 107 137 166 189 212 243 346 600 Continuous braking power kW 21.5 26 32 38 38 38 38 86 120 240 CL fuses a A 50 80 100 160 200 250 250 315 315 500 630 a V 690 690 690 660 660 660 660 660 660 1000 1000 Catalog number Weight

VW3 A7 231 VW3 A7 232 VW3 A7 233 VW3 A7 234 VW3 A7 235 VW3 A7 236 VW3 A7 237 VW3 A7 238 VW3 A7 239 VW3 A7 240 VW3 A7 241

kg 26.000 30.000 36.000 43.000 48.000 48.000 50.000 90.000 100.000 105.000 125.000

Presentation: page 64

Selection: pages 66 and 67

Dimensions: pages 104 and 105

Wiring diagrams: page 125

Global Catalog. Refer to Statement of Scope on page 2.

65

Selection

Variable speed drives for asynchronous motors


Altivar 71
Characteristic curves

Example of how to use characteristic curves


VW3 A7 204, A7 232 (Continuous braking power = 21.5 kW) (1)
Braking time (min.)

Example of how to use the curves: Required braking power of 27 kW. The intersection point between the braking time and the time between 2 braking operations must be on or below the relevant curve. Point A For a braking time of 2 minutes, there must be at least 50 seconds between 2 braking operations.

10 9
27 kW

8 7 6 5 4 3 2 1 0 0 1 2 3 4 5 6 7 8 9 10 11 Time between braking operations (min.)

33 kW

Network braking units


VW3 A7 204, A7 232 (Continuous braking power = 21.5 kW) (1)
Braking time (min.)

VW3 A7 205, A7 233 (Continuous braking power = 26 kW) (1)


Braking time (min.)

10 9
27 kW

10 9
33 kW

8 7 6 5
33 kW

8 7 6
45 kW

5 4 3 2 1 0

4 3 2 1 0 0 1 2 3 4 5 6 7 8 9 10 11 Time between braking operations (min.)

5 6 7 8 9 10 11 Time between braking operations (min.)

VW3 A7 206, A7 234 (Continuous braking power = 32 kW) (1)


Braking time (min.)

VW3 A7 207, A7 235 (Continuous braking power = 38 kW) (1)


Braking time (min.)

5 4,5
45 kW

5 4,5
52 kW

4 3,5 3 2,5 2 1,5 1 0,5 0 0 1 2 3 4 5 6 7 8 9 10 11


Time between braking operations (min.) 70 kW

4 3,5 3 2,5 2 1,5 1 0,5 0 0 1 2 3 4 5 6 7 8 9 10 11 Time between braking operations (min.)


90 kW

(1) Power indicated for a temperature of 35C. Presentation: page 64 Catalog numbers: page 65 Dimensions: pages 104 and 105 Wiring diagrams: page 125

66

Global Catalog. Refer to Statement of Scope on page 2.

Selection (continued)

Variable speed drives for asynchronous motors


Altivar 71
Characteristic curves

VW3 A7 208 (Continuous braking power = 38 kW) (1)


Braking time (min.)

VW3 A7 209, A7 239 (Continuous braking power = 86 kW) (1)


Braking time (min.)

5 4,5 4 3,5 3 2,5 2 1,5 1 0,5 0 0 1 2 3 4 5 6 7 8 9 10 11


Time between braking operations (min.) 135 kW 52 kW

5 4,5
110 kW

4 3,5 3 2,5
160 kW

2 1,5 1 0,5 0 0 1 2 3 4 5 6 7 8 9 10 11 Time between braking operations (min.)

VW3 A7 210, A7 240 (Continuous braking power = 120 kW) (1)


Braking time (min.)

VW3 A7 211 (Continuous braking power = 135 kW)


Braking time (min.)

5 4,5 4 3,5 3 2,5 2 1,5 1 0,5 0 0 1 2 3 4 5 6 7 8 9 10 11


Time between braking operations (min.) 200 kW 135 kW

5 4,5
170 kW

4 3,5 3 2,5 2 1,5 1 0,5 0 0 1 2 3 4 5 6 7 8 9 10 11 Time between braking operations (min.)


250 kW

VW3 A7 212 (Continuous braking power = 200 kW)


Braking time (min.)

VW3 A7 241 (Continuous braking power = 240 kW)


Braking time (min.)

5 4,5 230 kW 4 3,5 3 2,5 2 1,5 1 0,5 0 0 1 2 3 4 5 6 7 8 9 10 11 Time between braking operations (min.) 345 kW

5 4,5 4 3,5 3 2,5 2 1,5 1 0,5 0 0 1 2 3 4 5 6 7 8 9 10 11 Time between braking operations (min.)
400 kW 400 kW 260 kW 260 kW

(1) Power indicated for a temperature of 35C.

Presentation: page 64

Catalog numbers: page 3

Dimensions: pages 104 and 105

Wiring diagrams: page 125

Global Catalog. Refer to Statement of Scope on page 2.

67

Presentation

Variable speed drives for asynchronous motors


Altivar 71: reduction of current harmonics
Options: DC chokes

The main solutions for reducing current harmonics are as follows: b DC chokes, see below b Line chokes, see page 7274 b 16% and 10% passive filters, see page 75 b Use of passive filters with a DC choke, see page 75 These 4 solutions can be used on the same installation. It is always easier and less expensive to handle current harmonics at installation level as a whole rather than at the level of each individual unit, particularly when using passive filters and active compensators.
DC choke

DC chokes
DC chokes are used to reduce current harmonics in order to comply with standard 61000-3-2 for drives in which the line current is more than 16 A and less than 75 A. Using the DC choke with the drive complies with draft standard IEC/61000-3-12 provided that the RSCE u 120 (1) at the point of connection to the public network. 120 represents the minimum value of RSCE (1) for which the values in table 4 of draft standard IEC/61000-3-12 are not exceeded. It is the responsibility of the installer or the user to ensure that the device is connected correctly to a connection point with an RSCE u 120. The choke is connected to the drive power terminals. The DC choke is supplied as standard with ATV 71HD55M3X, HD75M3X and ATV 71HD90N4HC50N4 drives. Applications Reduction of current harmonics. Use with passive filters for greater reduction of current harmonics (see page 75). Maintaining the motor torque in relation to the AC line choke.
(1) Short-circuit ratio

L1 L2 L3
PC/

PA/+

PO

M1 3

Altivar 71

Characteristics: page 69

Catalog numbers: page 71

Dimensions: page 106

Wiring diagrams: pages 116 to 119

68

Global Catalog. Refer to Statement of Scope on page 2.

Presentation (continued)

Variable speed drives for asynchronous motors


Altivar 71: reduction of current harmonics
Options: DC chokes

Example of current harmonic levels up to harmonic order 49 for a 400 V/50 Hz supply with chokes connected between the PO and PA+ terminals on the Altivar 71.
Motor power kW HP 0.37 0.75 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 0.5 1 2 3 5 7.5 10 15 20 25 30 40 50 60 H037M3 H075M3 HU15M3 HU22M3 HU30M3 HU40M3 HU55M3 HU75M3 HD11M3X HD15M3X HD18M3X HD22M3X HD30M3X HD37M3X HD45M3X For ATV 71 drives Line supply Current harmonic levels Line Line Isc H1 H5 H7 H11 H13 current A kA A % % % % 1.5 3.05 6.04 8.33 11.12 14.53 19.2 26.1 36.6 48.6 58.7 70.28 96.9 116.1 138.7 5 5 5 5 5 5 8 15 15 15 15 22 22 22 22 1.4 2.81 5.55 7.64 10.19 13.29 17.9 23.9 34.2 55.8 55.8 65.92 88.78 107.9 130.5 26.7 31.99 33.65 34.89 35.17 36.23 30.68 35.23 30.91 25.51 25.51 29.81 36.68 33.09 30.15 18.4 20.91 21.59 21.11 20.68 20.51 17.26 21.09 17.12 13.46 13.46 15.91 19.42 16.4 13.86 9.1 8.88 8.14 8.78 8.71 8.73 8.75 8.82 8.86 8.73 8.73 8.7 8.38 8.59 8.65 7.7 7.36 6.84 6.72 6.48 6.2 6.31 6.71 6.36 6.32 6.32 6.15 5.67 5.59 5.38 H17 % 5.8 5.6 4.97 5.36 5.24 5.2 5.3 5.38 5.37 5.25 5.25 5.23 4.86 4.97 5.01 H19 % 5.1 4.63 4.19 4.1 3.94 3.73 4.03 4.09 4.08 4.21 4.21 3.99 3.44 3.54 3.49 H23 % 4.3 4.07 3.54 3.8 3.67 3.61 3.72 3.82 3.77 3.6 3.6 3.63 3.29 3.33 3.33 H25 % 3.8 3.42 3.08 3 2.88 2.71 2.98 2.98 3.01 3.11 3.11 2.95 2.52 2.6 2.55 H29 % 3.4 3.18 2.71 2.9 2.76 2.68 2.79 2.91 2.82 2.62 2.62 2.68 2.38 2.36 2.33 H31 % 3 2.71 2.43 2.37 2.27 2.14 2.36 2.35 2.37 2.42 2.42 2.32 1.98 2.03 1.96 H35 % 2.8 2.59 2.17 2.29 2.15 2.06 2.17 2.31 2.19 1.95 1.95 2.04 1.77 1.72 1.66 H37 % 2.5 2.24 2.01 1.95 1.87 1.76 1.94 1.92 1.94 1.93 1.93 1.89 1.62 1.63 1.53 H41 % 2.4 2.17 1.78 1.85 1.71 1.61 1.71 1.87 1.73 1.47 1.47 1.57 1.34 1.26 1.2 H43 % 2.2 1.91 1.7 1.66 1.58 1.49 1.63 1.63 1.62 1.56 1.56 1.57 1.34 1.32 1.19 H47 % 2.1 1.86 1.5 1.52 1.37 1.27 1.36 1.54 1.37 1.12 1.12 1.22 1.02 0.94 0.9 H49 % 1.9 1.66 1.47 1.44 1.37 1.28 1.4 1.4 1.38 1.26 1.26 1.32 1.12 1.06 0.9 36.3 41.27 42.4 43.33 43.22 43.91 38 43.96 38.14 35.34 32.31 36.62 43.51 39.24 35.7 THD (1)

3-phase supply voltage: 230 V 50 Hz

3-phase supply voltage: 400 V 50 Hz


0.75 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 220 250 280 315 355 400 500 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400 450 500 600 700 H075N4 HU15N4 HU22N4 HU30N4 HU40N4 HU55N4 HU75N4 HD11N4 HD15N4 HD18N4 HD22N4 HD30N4 HD37N4 HD45N4 HD55N4 HD75N4 HD90N4 HC11N4 HC13N4 HC16N4 HC20N4 HC25N4 HC25N4 HC28N4 HC31N4 HC40N4 HC40N4 HC50N4 1.77 3.34 4.83 6.13 8.24 10.81 15.01 21.1 28.2 33.9 40.87 54.1 66.43 83.11 98.6 134 158.81 193.81 228.92 276.22 340.29 378.67 423.72 471.17 528.66 607.3 675.3 833.84 5 5 5 5 5 22 10 9 12 12 22 20 22 22 22 22 35 35 35 50 50 50 50 50 50 50 50 50 1.61 3.03 4.4 5.67 7.51 9.83 13.8 19.3 25.8 31.9 37.85 50.6 62.6 75.56 91.69 125.9 145.1 175.7 209.3 251.7 313.6 344.9 390.1 437.3 492.2 555.5 623.4 779.9 34.6 35.55 35.79 31.61 36.16 34.85 34.09 35.22 35.22 28.36 32.79 29.97 28.49 38.31 32.94 30.65 36.72 38.91 37.23 38.29 36.03 38.91 36.61 34.78 34.19 38.78 36.78 33.73 23.7 23.53 22.77 18.82 21.63 23.08 20.49 20.11 20.01 15.16 18.73 16.26 15.01 20.96 16.76 14.43 20.66 21.7 20.02 20.22 17.85 19.7 17.59 15.9 15.08 17.83 15.99 13.22 8.9 8.95 8.7 9.41 9 9.68 8.57 8.95 8.98 8.85 8.6 8.75 8.63 8.24 8.5 8.4 8.33 8.24 8.26 8.19 8.16 8.11 8.11 8.1 8.03 7.88 7.86 7.82 7.8 7.65 7.11 6.82 8.17 4.05 6.43 6.5 6.49 6.18 6.42 6.27 6.08 5.81 5.68 5.4 6.19 6.03 5.8 5.59 5.3 5.22 5.04 4.92 4.79 4.59 4.43 4.26 5.6 5.61 5.41 5.88 5.52 6.12 5.28 5.41 5.43 5.39 5.28 5.32 5.23 4.85 4.98 4.84 4.93 4.78 4.76 4.66 4.59 4.47 4.46 4.44 4.36 4.14 4.1 3.99 4.8 4.74 4.36 4.57 4.17 5.18 3.95 4.02 4.02 4.04 4.09 4.07 4 3.48 3.62 3.52 3.78 3.56 3.51 3.32 3.25 3.04 3.04 3.04 2.98 2.64 2.64 2.63 4.1 4.06 3.89 4.24 3.93 4.45 3.78 3.8 3.82 3.78 3.75 3.73 3.65 3.33 3.38 3.21 3.43 3.28 3.26 3.13 3.05 2.93 2.9 2.86 2.78 2.58 2.53 2.38 3.5 3.49 3.2 3.38 3.05 3.83 2.89 2.95 2.94 2.98 3.03 3.01 2.97 2.54 2.67 2.59 2.75 2.56 2.52 2.37 2.32 2.15 2.16 2.16 2.1 1.84 1.85 1.81 3.2 3.16 3.01 3.28 3 3.48 2.9 2.86 2.88 2.83 2.85 2.79 2.71 2.44 2.44 2.25 2.56 2.42 2.38 2.26 2.17 2.07 2.02 1.97 1.88 1.74 1.67 1.5 2.8 2.76 2.53 2.67 2.4 3.04 2.28 2.32 2.32 2.34 2.4 2.37 2.34 2 2.09 2 2.13 1.98 1.94 1.82 1.76 1.63 1.62 1.6 1.54 1.37 1.35 1.26 2.6 2.57 2.43 2.63 2.38 2.85 2.32 2.23 2.24 2.18 2.25 2.15 2.07 1.85 1.81 1.61 1.99 1.87 1.82 1.7 1.6 1.52 1.46 1.4 1.31 1.21 1.13 0.95 2.3 2.28 2.09 2.19 1.98 2.52 1.88 1.9 1.9 1.9 1.97 1.94 1.9 1.64 1.69 1.58 1.72 1.58 1.55 1.43 1.37 1.27 1.24 1.21 1.14 1.04 0.99 0.88 2.2 2.15 2.01 2.16 1.93 2.4 1.9 1.77 1.78 1.7 1.81 1.69 1.61 1.42 1.37 1.17 1.59 1.47 1.42 1.31 1.2 1.14 1.07 1 0.92 0.85 0.78 0.63 1.9 1.94 1.77 1.86 1.68 2.14 1.59 1.6 1.6 1.58 1.67 1.62 1.58 1.38 1.39 1.25 1.4 1.28 1.24 1.14 1.05 0.99 0.95 0.9 0.84 0.78 0.73 0.61 1.9 1.83 1.7 1.8 1.58 2.06 1.58 1.42 1.43 1.33 1.48 1.33 1.26 1.1 1.04 0.88 1.29 1.19 1.12 1.02 0.91 0.85 0.78 0.72 0.65 0.6 0.54 0.44 1.7 1.68 1.53 1.6 1.45 1.85 1.37 1.37 1.37 1.33 1.44 1.38 1.32 1.17 1.14 0.96 1.16 1.06 1 0.91 0.82 0.78 0.73 0.67 0.61 0.58 0.53 0.43 44.95 45.48 45 40.08 44.72 45.19 42.25 43.1 43.06 35.23 40.4 36.99 35.13 45.59 39.29 36.2 44.26 46.45 44.23 45.11 42.07 45.26 42.35 40.05 39.15 44.12 41.6 37.8

(1) Total harmonic distortion conforming to draft standard IEC 61000-3-12

Presentation: page 68

Catalog numbers: page 71

Dimensions: page 106

Wiring diagrams: pages 116 to 119

Global Catalog. Refer to Statement of Scope on page 2.

69

Characteristics

Variable speed drives for asynchronous motors


Altivar 71: reduction of current harmonics
Options: DC chokes

General characteristics
Degree of protection Maximum relative humidity Ambient air temperature around the device Maximum operating altitude Voltage drop Maximum current Operation Storage C C m IP 20 95% - 10+ 50 without derating Up to 60C with current derating of 2.2% per C above 50C - 40+ 65 1000 without derating 10003000 with current derating of 1% per additional 100 m 4 to 6% 1.65 x nominal current for 60 seconds Earth 10 mm2 (AWG 6) 1.21.4 Nm 10 mm2 (AWG 6) 1.21.4 Nm 10 mm2 (AWG 6) 1.21.4 Nm 10 mm2 (AWG 6) 1.21.4 Nm 10 mm2 (AWG 6) 1.21.4 Nm Power supply 2.5 mm2 (AWG 12) 0.40.6 Nm 4 mm2 (AWG 10) 0.50.8 Nm 6 mm2 (AWG 8) 0.81 Nm 10 mm2 (AWG 6) 1.21.4 Nm 35 mm2 (AWG 0) 2.53 Nm Connected on a bar, 9 Connected on a bar, 9

Connection characteristics
Type of terminal Maximum connection capacity and tightening torque VW3 A4 501505 VW3 A4 506 VW3 A4 507 VW3 A4 508, 509 VW3 A4 510 VW3 A4 511 VW3 A4 512

Presentation: page 68

Catalog numbers: page 71

Dimensions: page 106

Wiring diagrams: pages 116 to 119

70

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers

Variable speed drives for asynchronous motors


Altivar 71: reduction of current harmonics
Options: DC chokes

DC chokes (1)
For drives Inductance value mH 18 6.8 3.2 2.2 1.6 1.2 0.7 0.52 0.22 0.09 Nominal current A 2.25 8 14.3 19.2 27.4 44 36 84.5 171.2 195 Loss W 7.7 22.5 32 33 43 61 30.5 77 86 73 VW3 A4 501 VW3 A4 503 VW3 A4 505 VW3 A4 506 VW3 A4 507 VW3 A4 508 VW3 A4 509 VW3 A4 510 VW3 A4 511 VW3 A4 512 Catalog number Weight kg 0.650 1.700 2.200 2.500 3.000 4.500 2.500 6.200 15.500 10.000

3-phase supply voltage: 200240 V 50/60 Hz


ATV 71H037M3 ATV 71H075M3 ATV 71HU15M3 ATV 71HU22M3 ATV 71HU30M3 ATV 71HU40M3, HU55M3 ATV 71HU75M3 ATV 71HD11M3X, HD15M3X ATV 71HD18M3X, HD22M3X ATV 71HD30M3X HD45M3X

3-phase supply voltage: 380480 V 50/60 Hz


ATV 71H075N4 18 2.25 7.7 VW3 A4 501 0.650 ATV 71HU15N4 10 4.3 11 VW3 A4 502 1.000 ATV 71HU22N4, 6.8 8 22.5 VW3 A4 503 1.700 HU30N4 ATV 71HU40N4 3.9 10.7 27 VW3 A4 504 1.650 ATV 71HU55N4 3.2 14.3 32 VW3 A4 505 2.200 ATV 71HU75N4 2.2 19.2 33 VW3 A4 506 2.500 ATV 71HD11N4 1.6 27.4 43 VW3 A4 507 3.000 ATV 71HD15N4, 1.2 44 57.5 VW3 A4 508 4.300 HD18N4 ATV 71HD22N4 0.52 84.5 98.3 VW3 A4 510 5.600 HD37N4 ATV 71HD45N4 0.22 171.2 128 VW3 A4 511 9.100 HD75N4 (1) With ATV 71HD55M3X, HD75M3X and ATV 71HD90N4HC50N4 drives, the DC choke is supplied as standard with the drive.

Presentation: page 68

Characteristics: page 69

Dimensions: page 106

Wiring diagrams: pages 116 to 119

Global Catalog. Refer to Statement of Scope on page 2.

71

Presentation

Variable speed drives for asynchronous motors


Altivar 71: reduction of current harmonics
Options: line chokes

L1 L2 L3
Line choke

Line chokes
Altivar 71 M1 3

A line choke can be used to provide improved protection against overvoltages on the line supply and to reduce harmonic distortion of the current produced by the drive. Line chokes are compulsory on ATV 71HU40M3HU75M3 drives supplied with a single phase 200240 V 50/60 Hz supply voltage. The recommended chokes are used to limit the line current. They have been developed in line with standard EN 50178 (VDE 0160 level 1 high energy overvoltages on the line supply). The choke values are defined for a voltage drop between 3% and 5% of the nominal supply voltage. Values higher than this will cause loss of torque. These chokes should be installed upstream of the drive. Applications The use of line chokes is recommended in particular under the following circumstances: b Close connection of several drives in parallel b Line supply with significant disturbance from other equipment (interference, overvoltages) b Line supply with voltage imbalance between phases above 1.8% of the nominal voltage b Drive supplied by a line with very low impedance (in the vicinity of a power transformer 10 times more powerful than the drive rating) b Installation of a large number of frequency converters on the same line b Reducing overloads on the cos correction capacitors, if the installation includes a power factor correction unit

Characteristics: page 73

Catalog numbers: page 74

Dimensions: page 106

Wiring diagrams: pages 116 to 119

72

Global Catalog. Refer to Statement of Scope on page 2.

Characteristics

Variable speed drives for asynchronous motors


Altivar 71: reduction of current harmonics
Options: line chokes

General characteristics
Type of choke Conformity to standards Degree of protection Atmospheric pollution Degree of pollution Vibration resistance Shock resistance Maximum relative humidity Ambient air temperature around the device Isolation class Clearance distance in air Leakage distance in air Maximum operating altitude Voltage drop Maximum current Choke Terminals VW3 A4 551... 553 VW3 A4 554... 555 VW3 A4 556... 560 VW3 A4 561 567 EN 50178 (VDE 0160 level 1 high energy overvoltages on the line supply), IEC 60076 (with HD 398) IP 00 IP 20 IP 10 IP 00 3 C2, 3B1, 3S1 conforming to IEC 721.3.3 2 conforming to EN 50178 1.5 mm from 313 Hz, 1 gn from 13200 Hz, conforming to IEC 60068-2 15 gn for 11 ms conforming to IEC/EN 60068-2-27 95% 0+ 45 without derating Up to + 55C with current derating of 2% per C above 45C - 25+ 70 F 5.5 conforming to IEC 60664 11.5 conforming to IEC 60664 1000 without derating 10003000 with current derating of 1% per additional 100 m Between 3% and 5% of the nominal supply voltage. Values higher than this will cause loss of torque 1.65 x nominal current for 60 seconds

Operation Storage

C C mm mm m

Connection characteristics
Maximum connection capacity and tightening torque VW3 A4 551, 552 VW3 A4 553 VW3 A4 554 VW3 A4 555 VW3 A4 556 VW3 A4 557, 558 VW3 A4 559561 VW3 A4 562567 2.5 mm2, (AWG 12) 0.40.6 Nm 6 mm2, (AWG 8) 0.81 Nm 16 mm2, (AWG 4) 1.21.4 Nm 35 mm2, (AWG 0) 2.53 Nm Connected on a bar, 6.5 mm Connected on a bar, 9 mm Connected on a bar, 11 mm Connected on a bar, 13 mm

Presentation: page 72

Catalog numbers: page 74

Dimensions: page 106

Wiring diagrams: pages 116 to 119

Global Catalog. Refer to Statement of Scope on page 2.

73

Catalog numbers

Variable speed drives for asynchronous motors


Altivar 71: reduction of current harmonics
Options: line chokes

Line chokes
For drives Line Line choke supply Inductance Nominal Saturation Loss Line Isc value current current kA mH A A W 5 5 5 5 22 22 22 22 35 35 10 4 2 1 1 0.5 0.3 0.15 0.049 0.038 4 10 16 30 30 60 100 230 429 613 855 1150 45 65 75 90 90 94 260 400 278 307 Catalog number Weight

kg VW3 A4 551 VW3 A4 552 VW3 A4 553 VW3 A4 554 VW3 A4 554 VW3 A4 555 VW3 A4 556 VW3 A4 557 VW3 A4 562 VW3 A4 563 1.500 3.000 3.500 6.000 6.000 11.000 16.000 45.000 50.000 59.000

3-phase supply voltage: 200240 V 50/60 Hz


ATV 71H037M3...H075M3 ATV 71HU15M3...HU22M3 ATV 71HU30M3 ATV 71HU40M3 ATV 71HU55M3 ATV 71HU75M3, HD11M3X ATV 71HD15M3X ATV 71HD18M3XHD45M3X ATV 71HD55M3X ATV 71HD75M3X

3-phase supply voltage: 380480 V 50/60 Hz


ATV 71H075N4, HU15N4 ATV 71HU22N4HU40N4 ATV 71HU55N4, HU75N4 ATV 71HD11N4, HD15N4 ATV 71HD18N4, HD22N4 ATV 71HD30N4HD55N4 ATV 71HD75N4 ATV 71HD90N4 ATV 71HC11N4 ATV 71HC13N4 ATV 71HC16N4 ATV 71HC20N4 ATV 71HC25N4 Motor P 350 hp (220 kW) Motor P 400 hp (250 kW) 5 5 22 22 22 22 22 35 35 35 50 35 50 10 4 2 1 0.5 0.3 0.15 0.155 0.12 0.098 0.066 0.049 0.049 4 10 16 30 60 100 230 184 222 264 344 429 429 370 445 530 685 855 855 45 65 75 90 94 260 400 220 230 245 258 278 278 VW3 A4 551 VW3 A4 552 VW3 A4 553 VW3 A4 554 VW3 A4 555 VW3 A4 556 VW3 A4 557 VW3 A4 558 VW3 A4 559 VW3 A4 560 VW3 A4 561 VW3 A4 562 VW3 A4 562 1.500 3.000 3.500 6.000 11.000 16.000 45.000 31.000 35.000 43.000 47.000 50.000 50.000

50

0.038

509

1025

280

VW3 A4 563

59.000

ATV 71HC28N4 ATV 71HC31N4 ATV 71HC40N4 Motor P 355 kW Motor P 600 hp (400 kW)

50 50 50 50

0.038 0.038 0.02 0.049

613 613 745 2 x 429

1150 1150 1150 855

307 307 335 278

VW3 A4 564 VW3 A4 564 VW3 A4 565 VW3 A4 566

73.000 73.000 70.000 100.000

ATV 71HC50N4

50

0.038

2 x 509

1025

280

VW3 A4 567

118.000

Presentation: page 72

Characteristics: page 73

Dimensions: page 106

Wiring diagrams: pages 116 to 119

74

Global Catalog. Refer to Statement of Scope on page 2.

Presentation, characteristics

Variable speed drives for asynchronous motors


Altivar 71: reduction of current harmonics
Options: passive filters

Passive filters
L1 L2 L3 Altivar 71

The passive filter is used to reduce current harmonics with total harmonic distortion factors of less than 16% or 10%. These ratios may be less than 10% or 5% if used with a DC choke, see page 68.

Applications Reduction of current harmonics in order to use drives in the first environment.
Passive filter

General characteristics
Degree of protection Maximum relative humidity Ambient air temperature around the device IP 20 Class F humidity without condensation 5%85% 5+ 40 without derating Up to 55C with current derating of 3% per additional C - 25+ 55 1000 without derating 10004000 with current derating of 5% per additional 1000 m 400 V a 380415 50 5% 1.5 x Irms (A) 98% (2% of thermal losses) % 16 At 75% of the line current: 0.85 At 100% of the line current: 0.99 At 150% of the line current: 1 460 V a 440480 60 5%

Operation Storage

C C m

Maximum operating altitude

Electrical characteristics
Range Nominal voltage 10% Operating frequency Overload capacity Efficiency THDI (1) Cos V

Connection characteristics
VW3 A4 601604 16 mm2 VW3 A4 605609 50 mm2 VW3 A4 610, 611, 614 Connected on a bar, 12.5 Connected on a bar, 16.5 VW3 A4 612, 613, 615617 VW3 A4 621, 622 16 mm2 VW3 A4 623627 50 mm2 VW3 A4 628, 629 Connected on a bar, 12.5 VW3 A4 630637 Connected on a bar, 16.5 16 mm2 VW3 A4 641644 VW3 A4 645648 50 mm2 VW3 A4 649 Connected on a bar, 12.5 Connected on a bar, 16.5 VW3 A4 650655 16 mm2 VW3 A4 661663 VW3 A4 664666 50 mm2 VW3 A4 667, 668 Connected on a bar, 12.5 Connected on a bar, 16.5 VW3 A4 669675 (1) The total current harmonic distortion (THDI) is indicated for a total voltage harmonic distortion (THDU) < 2% and a short-circuit ratio (RSCE) > 66%. If these conditions are not adhered to, the total current harmonics will be reduced without any guarantee of level. Maximum connection capacity

Catalog numbers: page 76

Dimensions: page 107

Wiring diagrams: page 124

Global Catalog. Refer to Statement of Scope on page 2.

75

Catalog numbers

Variable speed drives for asynchronous motors


Altivar 71: reduction of current harmonics
Options: passive filters

Passive filters: 3-phase power supply 400 V 50/60 Hz


Motor rating kW 0.75 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 220 250 280 315 355 400 500 HP 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400 450 500 600 700 ATV 71H075N4 ATV 71HU15N4 ATV 71HU22N4 ATV 71HU30N4 ATV 71HU40N4 ATV 71HU55N4 ATV 71HU75N4 ATV 71HD11N4 ATV 71HD15N4 ATV 71HD18N4 ATV 71HD22N4 ATV 71HD30N4 ATV 71HD37N4 ATV 71HD45N4 ATV 71HD55N4 ATV 71 HD75N4 ATV 71HD90N4 ATV 71HC11N4 ATV 71HC13N4 ATV 71HC16N4 ATV 71HC20N4 ATV 71HC25N4 ATV 71HC25N4 ATV 71HC28N4 ATV 71HC31N4 ATV 71HC40N4 ATV 71HC40N4 ATV 71HC50N4 For drives Line supply Line current A 1.70 3.60 5.10 6.90 9.50 13.00 16.50 25.60 29.50 38.30 43.00 58.90 71.30 82.90 100.00 139.50 156.00 187.00 234.00 287.00 353.50 390.00 445.00 485.00 543.00 592.00 670.00 840.00 Filter lrms A 6 6 6 10 10 19 19 26 35 43 43 72 72 101 101 144 144 180 216 289 370 370 434 578 578 578 740 867 Catalog number Weight kg VW3 A4 601 VW3 A4 601 VW3 A4 601 VW3 A4 602 VW3 A4 602 VW3 A4 603 VW3 A4 603 VW3 A4 604 VW3 A4 605 VW3 A4 606 VW3 A4 606 VW3 A4 607 VW3 A4 607 VW3 A4 608 VW3 A4 608 VW3 A4 609 VW3 A4 609 VW3 A4 610 VW3 A4 611 VW3 A4 612 VW3 A4 613 VW3 A4 613 VW3 A4 614 VW3 A4 615 VW3 A4 615 VW3 A4 615 VW3 A4 616 VW3 A4 617 15.000 15.000 15.000 19.000 19.000 21.000 21.000 22.000 34.000 38.000 38.000 56.000 56.000 69.000 69.000 97.000 97.000 103.000 112.000 135.000 155.000 155.000 224.000 270.000 270.000 270.000 310.000 305.000

THDI 16% (1)

THDI 10% (1) 0.75 1 ATV 71H075N4 1.70 6 VW3 A4 621 21.000 1.5 2 ATV 71HU15N4 3.60 6 VW3 A4 621 21.000 2.2 3 ATV 71HU22N4 5.10 6 VW3 A4 621 21.000 3 ATV 71HU30N4 6.90 10 VW3 A4 622 27.000 4 5 ATV 71HU40N4 9.50 10 VW3 A4 622 27.000 5.5 7.5 ATV 71HU55N4 13.00 19 VW3 A4 623 28.000 7.5 10 ATV 71HU75N4 16.50 19 VW3 A4 623 28.000 11 15 ATV 71HD11N4 25.60 26 VW3 A4 624 40.000 15 20 ATV 71HD15N4 29.50 35 VW3 A4 625 49.000 18.5 25 ATV 71HD18N4 38.30 43 VW3 A4 626 52.000 22 30 ATV 71HD22N4 43.00 43 VW3 A4 626 52.000 30 40 ATV 71HD30N4 58.90 72 VW3 A4 627 88.000 37 50 ATV 71HD37N4 71.30 72 VW3 A4 627 88.000 45 60 ATV 71HD45N4 82.90 101 VW3 A4 628 150.000 55 75 ATV 71HD55N4 100.00 101 VW3 A4 628 150.000 75 100 ATV 71HD75N4 139.50 144 VW3 A4 629 167.000 90 125 ATV 71HD90N4 156.00 144 VW3 A4 629 167.000 110 150 ATV 71HC11N4 187.00 180 VW3 A4 630 178.000 132 200 ATV 71HC13N4 234.00 216 VW3 A4 631 224.000 160 250 ATV 71HC16N4 287.00 289 VW3 A4 632 271.000 200 300 ATV 71HC20N4 353.50 370 VW3 A4 633 320.000 220 350 ATV 71HC25N4 390.00 370 VW3 A4 633 320.000 250 400 ATV 71HC25N4 445.00 434 VW3 A4 634 448.000 280 450 ATV 71HC28N4 485.00 578 VW3 A4 635 542.000 315 500 ATV 71HC31N4 543.00 578 VW3 A4 635 542.000 355 ATV 71HC40N4 592.00 578 VW3 A4 635 542.000 400 600 ATV 71HC40N4 670.00 740 VW3 A4 636 568.000 500 700 ATV 71HC50N4 840.00 867 VW3 A4 637 813.000 (1) By adding a DC choke (see page 68), we get: - THD 10% with VW3 A4 601617 - THD 5% with VW3 A4 621637 These reduced current harmonics are obtained on condition that the THDU is < 2% and the RSCE > 66%.
Presentation: page 75 Characteristics: page 75 Dimensions: page 107 Wiring diagrams: page 124

76

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers (continued)

Variable speed drives for asynchronous motors


Altivar 71: reduction of current harmonics
Options: passive filters

Passive filters: 3-phase power supply 460 V 50/60 Hz


Motor rating kW 0.75 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 220 250 280 315 355 400 500 HP 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400 450 500 600 700 ATV 71H075N4 ATV 71HU15N4 ATV 71HU22N4 ATV 71HU30N4 ATV 71HU40N4 ATV 71HU55N4 ATV 71HU75N4 ATV 71HD11N4 ATV 71HD15N4 ATV 71HD18N4 ATV 71HD22N4 ATV 71HD30N4 ATV 71HD37N4 ATV 71HD45N4 ATV 71HD55N4 ATV 71 HD75N4 ATV 71HD90N4 ATV 71HC11N4 ATV 71HC13N4 ATV 71HC16N4 ATV 71HC20N4 ATV 71HC25N4 ATV 71HC25N4 ATV 71HC28N4 ATV 71HC31N4 ATV 71HC40N4 ATV 71HC40N4 ATV 71HC50N4 For drives Line supply Line current A 1.60 3.00 4.20 6.20 6.90 10.10 13.10 19.00 24.10 31.70 36.00 46.40 58.70 67.90 82.60 108.00 158.00 187.00 234.00 287.00 353.00 390.00 444.00 485.00 543.00 591.80 669.40 840.00 Filter lrms A 6 6 6 6 10 10 19 19 26 35 35 43 72 72 101 101 180 180 289 289 370 370 432 578 578 578 740 867 Catalog number Weight kg VW3 A4 641 VW3 A4 641 VW3 A4 641 VW3 A4 641 VW3 A4 642 VW3 A4 642 VW3 A4 643 VW3 A4 643 VW3 A4 644 VW3 A4 645 VW3 A4 645 VW3 A4 646 VW3 A4 647 VW3 A4 647 VW3 A4 648 VW3 A4 648 VW3 A4 649 VW3 A4 649 VW3 A4 650 VW3 A4 650 VW3 A4 651 VW3 A4 651 VW3 A4 652 VW3 A4 653 VW3 A4 653 VW3 A4 653 VW3 A4 654 VW3 A4 655 15.000 15.000 15.000 15.000 19.000 19.000 23.000 23.000 34.000 42.000 42.000 45.000 61.000 61.000 75.000 75.000 107.000 107.000 145.000 145.000 185.000 185.000 238.000 290.000 290.000 290.000 370.000 435.000

THDI 16% (1)

THDI 10% (1) 0.75 1 ATV 71H075N4 1.70 6 VW3 A4 661 21.000 1.5 2 ATV 71HU15N4 3.60 6 VW3 A4 661 21.000 2.2 3 ATV 71HU22N4 5.10 6 VW3 A4 661 21.000 3 ATV 71HU30N4 6.90 6 VW3 A4 661 21.000 4 5 ATV 71HU40N4 9.50 10 VW3 A4 662 27.000 5.5 7.5 ATV 71HU55N4 13.00 10 VW3 A4 662 27.000 7.5 10 ATV 71HU75N4 16.50 19 VW3 A4 663 28.000 11 15 ATV 71HD11N4 25.60 19 VW3 A4 663 28.000 15 20 ATV 71HD15N4 29.50 26 VW3 A4 664 41.000 18.5 25 ATV 71HD18N4 38.30 35 VW3 A4 665 49.000 22 30 ATV 71HD22N4 43.00 35 VW3 A4 665 49.000 30 40 ATV 71HD30N4 58.90 43 VW3 A4 666 56.000 37 50 ATV 71HD37N4 71.30 72 VW3 A4 667 80.000 45 60 ATV 71HD45N4 82.90 72 VW3 A4 668 98.000 55 75 ATV 71HD55N4 100.00 101 VW3 A4 668 98.000 75 100 ATV 71HD75N4 139.50 101 VW3 A4 668 98.000 90 125 ATV 71HD90N4 156.00 180 VW3 A4 669 151.000 110 150 ATV 71HC11N4 187.00 180 VW3 A4 669 151.000 132 200 ATV 71HC13N4 234.00 289 VW3 A4 670 215.000 160 250 ATV 71HC16N4 287.00 289 VW3 A4 670 215.000 200 300 ATV 71HC20N4 353.50 370 VW3 A4 671 250.000 220 350 ATV 71HC25N4 390.00 370 VW3 A4 671 250.000 250 400 ATV 71HC25N4 445.00 432 VW3 A4 672 342.000 280 450 ATV 71HC28N4 485.00 578 VW3 A4 673 430.000 315 500 ATV 71HC31N4 543.00 578 VW3 A4 673 430.000 355 ATV 71HC40N4 592.00 578 VW3 A4 673 430.000 400 600 ATV 71HC40N4 670.00 740 VW3 A4 674 500.000 500 700 ATV 71HC50N4 840.00 867 VW3 A4 675 645.000 (1) By adding a DC choke (see page 68), we get: - THD 10% with VW3 A4 641655 - THD 5% with VW3 A4 661675 These reduced current harmonics are obtained on condition that the THDU is < 2% and the RSCE > 66%.
Presentation: page 75 Characteristics: page 75 Dimensions: page 107 Wiring diagrams: page 124

Global Catalog. Refer to Statement of Scope on page 2.

77

Presentation

Variable speed drives for asynchronous motors


Altivar 71
Options: additional EMC input filters

L1 L2 L3 M1 3

Altivar 71 drives, except for the ATV 71HpppM3X, have built-in radio interference input filters to meet the EMC standard for variable speed electrical power drive products IEC/EN 61800-3, edition 2, category C2 or C3 in environment 1 or 2 and to comply with the European directive on EMC (electromagnetic compatibility).
For drives EN 55011 Maximum length of shielded cable according to class A (1) Group 1 (2) Group 2 (2) LF (3) HF (3) LF (3) HF (3) m m m m 10 5 10 5 10 5 10 5 50 25 Switching frequency LF HF kHz kHz 34 4.116 22.5 24 2.612 4.18

ATV 71pppppM3 ATV 71pppppN4 with built-in filter

ATV 71H037M3HU22M3 ATV 71HU30M3HU75M3 ATV 71H075N4HU40N4 ATV 71HU55N4HD15N4 ATV 71HD18N4HC50N4 For drives

ATV 71HpppM3 ATV 71H075N4HD30N4 ATV 71HD37N4HD75N4 ATV 71HD90N4HC50N4

Additional EMC input filters


L1 L2 L3
Additional EMC filter

Altivar 71

M1 3

Applications Additional EMC input filters can be used to meet more stringent requirements and are designed to reduce conducted emissions on the line supply below the limits of standard EN 55011 group 1, class A or B (2). These additional filters are mounted under the drives. They can be mounted on the side of the product for ATV 71HpppM3, ATV 71HD11M3XHD45M3X and ATV 71H075N4HD75N4 drives. They act as a support for the drives and are fixed to them via tapped holes. Use according to the type of network Use of these additional filters is only possible on TN (connected to neutral) and TT (neutral to earth) type networks. Standard IEC/EN 61800-3, appendix D2.1, states that on IT networks (impedance or isolated neutral), filters can cause permanent insulation monitors to operate in a random manner. In addition, the effectiveness of additional filters on this type of network depends on the type of impedance between neutral and ground, and therefore cannot be predicted. In the case of a machine which needs to be installed on an IT network, one solution consists of inserting an isolation transformer and placing the machine locally on a TN or TT network.
(1) Maximum lengths for shielded cables connecting motors to drives, for a factory-set switching frequency of 2.5 or 4 kHz depending on the rating (2). If motors are connected in parallel, it is the sum of all cable lengths that should be taken into account. (2) See page 10. (3) LF: low switching frequency. HF: high switching frequency. These frequencies depend on the drive rating.

Characteristics: Page 79

Catalog numbers: Pages 80 and 81

Dimensions: Pages 108 and 109

Wiring diagrams: Page 124

78

Global Catalog. Refer to Statement of Scope on page 2.

Characteristics

Variable speed drives for asynchronous motors


Altivar 71
Options: additional EMC input filters

General characteristics
EMC filter Conformity to standards Degree of protection Maximum relative humidity Ambient temperature around the unit Maximum operating altitude Operation Storage C C m VW3 A4 401409 EN 133200 IP 20 and IP 41 on upper part VW3 A4 410414

IP 00 IP 30 with VW3 A9 601, 602 kits 93% without condensation or dripping water conforming to IEC 68-2-3 - 10+ 50 - 25+ 45 - 40+ 65 - 25+ 85 1000 without derating 10003000 by derating the current by 1% per additional 100 m Limited to 2000 m for the Corner Grounded distribution network 1.5 mm peak to peak from 313 Hz, 1 gn peak from 13150 Hz, in accordance with IEC 60068-2-6 15 gn for 11 ms, in accordance with IEC 60068-2-27 240 + 10% 480 + 10% 4 mm2 (AWG 10). 0.6 Nm 6 mm2 (AWG 8). 1.5 Nm 10 mm2 (AWG 6). 1.5 Nm 16 mm2 (AWG 4). 2 Nm 50 mm2 (AWG 0). 6 Nm 150 mm2 (300 kcmil). 25 Nm 25 mm2 (AWG 2). 4 Nm Bar connection, M10 Bar connection, 2 x M12

Vibration resistance Shock resistance Maximum nominal voltage

50/60 Hz 3-phase

Connection characteristics
Maximum connection capacity VW3 A4 401 and tightening torque VW3 A4 402 VW3 A4 403 VW3 A4 404 VW3 A4 405407 VW3 A4 408 VW3 A4 409 VW3 A4 410412 VW3 A4 413

Presentation: Page 78

Catalog numbers: Pages 80 and 81

Dimensions: Pages 108 and 109

Wiring diagrams: Page 124

Global Catalog. Refer to Statement of Scope on page 2.

79

Catalog numbers

Variable speed drives for asynchronous motors


Altivar 71
Options: additional EMC input filters

Additional EMC input filters


For drives Maximum length of shielded cable (1) EN 55011 (5) EN 55011 (5) class A Gr1 class B Gr1 LF (6) HF (6) LF (6) HF (6) m m m m 100 100 100 100 100 100 100 100 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 20 20 20 20 25 25 25 25 In (2) Il (3) Loss (4) Catalog number Weight

A 12 26 35 46 72 90 180 273

mA 4 4.4 3 10 33 33 80 285

W 10 18 24 19 34 34 58 60 VW3 A4 401 VW3 A4 402 VW3 A4 403 VW3 A4 404 VW3 A4 405 VW3 A4 406 VW3 A4 408 VW3 A4 410

kg 2.200 4.000 5.800 7.000 12.000 15.000 40.000 22.000

3-phase supply voltage: 200240 V 50/60 Hz


ATV 71H037M3HU15M3 ATV 71HU22M3HU40M3 ATV 71HU55M3 ATV 71HU75M3 ATV 71HD11M3X, HD15M3X ATV 71HD18M3X, HD22M3X ATV 71HD30M3X...HD45M3X ATV 71HD55M3X, HD75M3X

3-phase supply voltage: 380480 V 50/60 Hz


ATV 71H075N4HU22N4 ATV 71HU30N4, HU40N4 ATV 71HU55N4, HU75N4 ATV 71HD11N4 ATV 71HD15N4 (7), HD18N4 ATV 71HD22N4 ATV 71HD30N4, HD37N4 ATV 71HD45N4HD75N4 ATV 71HD90N4HC13N4 ATV 71HC16N4HC28N4 ATV 71HC31...HC40N4 ATV 71HC50N4 100 100 100 100 300 300 300 300 300 300 300 300 50 50 50 50 200 200 200 200 150 150 150 150 50 50 50 50 100 100 100 100 50 50 50 50 20 20 20 20 100 100 100 100 25 25 25 25 12 26 35 46 72 90 92 180 273 546 728 1456 7 8 7 14 60 60 60 140 500 500 500 200 5 6 14 13 14 11 30 58 60 125 210 380 VW3 A4 401 VW3 A4 402 VW3 A4 403 VW3 A4 404 VW3 A4 405 VW3 A4 406 VW3 A4 407 VW3 A4 408 VW3 A4 410 VW3 A4 411 VW3 A4 412 VW3 A4 413 2.200 4.000 5.800 7.000 12.000 15.000 17.000 40.000 22.000 25.000 25.000 34.000

(1) The filter selection tables give the maximum lengths for shielded cables connecting motors to drives for a switching frequency of 1 to 16 kHz (5). These limits are given as examples only as they vary depending on the stray capacitance of the motors and the cables used. If motors are connected in parallel, it is the sum of the cable lengths that should be taken into account. (2) Filter nominal current. (3) Maximum earth leakage current at 230 V and at 400 V 50 Hz on a TT network. (4) Via thermal dissipation. (5) See page 10. (6) LF: low switching frequency. HF: high switching frequency. These frequencies depend on the drive rating: For drives Switching frequency LF HF kHz kHz ATV 71HpppM3 34 4.116 ATV 71H075N4HD11N4 ATV 71HD11M3X, HD15M3X 3.5...4 4.112 ATV 71HD15N4HD30N4 ATV 71HD18M3X...HD45M3X 22.5 2.612 ATV 71HD37N4...HD75N4 ATV 71HD55M3X, HD75M3X 24 4.18 ATV 71HD90N4, HC50N4 24 4.18

(7) It is possible to use a special filter VW3 A4 409 with a leakage current Il (3) of 14 mA which enables a maximum motor cable length of 100 m.

Presentation: Page 78

Characteristics: Page 79

Dimensions: Pages 108 and 109

Wiring diagrams: Page 124

80

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers (continued)

Variable speed drives for asynchronous motors


Options: additional EMC input filters

IP 30 protection kits
Description Mechanical device consisting of an IP 30 cover and cable clips For filters VW3 A4 410, 411 Catalog number VW3 A9 601 Weight kg

VW3 A4 412, 413

VW3 A9 602

Presentation: Page 78

Characteristics: Page 79

Dimensions: Page 109

Wiring diagrams: Page 124

Global Catalog. Refer to Statement of Scope on page 2.

81

Presentation

Variable speed drives for asynchronous motors


Altivar 71: output filters

The Altivar 71 drive includes as standard a software function used to limit overvoltages at the motor terminals. Depending on the cable lengths or the type of application, it may be necessary to use output filters: b Motor chokes used to limit the dv/dt b Sinusoidal filters that are particularly effective for long cable runs
Cable length (2) 1050 m 50100 m 100150 m 150300 m Motor choke 300600 m 6001000 m

Shielded cable
ATV 71HpppM3 ATV 71H075N4HD15N4 ATV 71HpppM3X ATV 71HD18N4HC50N4 Software function Motor choke (1) Software function (1)

Unshielded cable
ATV 71H037M3...HU15M3 Software function (1) Motor choke or ATV 71H075N4...HU22N4 sinusoidal filter ATV 71HU22M3...HU30M3 Software function (1) Motor choke ATV 71HU55N4HU75N4 ATV 71HU40M3HU75M3 Software function (1) Motor choke ATV 71HU75N4HD15N4 ATV 71HpppM3X Software function (1) Motor choke ATV 71HD18N4HC50N4 (1) The software function limits the overvoltage at the motor terminals to twice the DC bus voltage. For any application with braking cycles, the DC bus voltage rises to more than the supply voltage multiplied by 2. You must check the electrical characteristics of the motor before using this function. (2) For an application with several motors connected in parallel, the cable length must include all cabling. Type of recommended cable: b Shielded cables: GORSE cable, type GUOSTV-LS/LH; PROTOFLEX cable, type EMV2YSL CY b Unshielded cables: GORSE cable, type H07 RN-F4GXX; BELDEN cable, type 2950X Sinusoidal filter Sinusoidal filter Sinusoidal filter

Wiring diagrams: page 124

82

Global Catalog. Refer to Statement of Scope on page 2.

Presentation, characteristics

Variable speed drives for asynchronous motors


Altivar 71: output filters
Options: motor chokes

Motor chokes
Above a certain motor cable length, it is advisable to insert a motor choke between the drive and the motor. This maximum length depends on the drive rating and the type of motor cable:
Altivar 71 M1 3
Motor choke

For drives

ATV 71HpppM3 ATV 71HD11M3X, HD15M3X ATV 71H075N4HD18N4 ATV 71HD18M3XHD75M3X ATV 71HD22N4HC50N4

Maximum length of motor cable (1) Shielded cable Unshielded cable m m u 50 u 100

u 100

u 200

The choke is used to: b Limit the dv/dt to 500 V/s b Limit overvoltages on the motor terminals to: v 1000 V to 400 V a (rms value) v 1150 V to 460 V a (rms value) b Filter interference caused by opening a contactor placed between the filter and the motor b Reduce the motor earth leakage current

General characteristics (2)


ATV 71HpppM3 ATV 71HD11M3X, HD15M3X ATV 71H075N4HD30N4 ATV 71HD18M3XHD75M3X ATV 71HD37N4HC50N4 Maximum drive output frequency Degree of protection Type of choke Drive switching frequency kHz VW3 A5 101103 4 VW3 A5 104108

kHz Hz

2.5 100 IP 00

Thermal protection Temperature controlled switch (3) Ambient temperature around the unit

Tripping temperature Maximum voltage Maximum current Operation Storage

C V A C C

By temperature controlled switch 125 a 250 0.5 - 10+ 50 - 25+ 70

IP 00 IP 20 with kits VW3 A9 612 and VW3 A9 613

Connection characteristics
10 mm2 (AWG 6) 1.5 Nm Connected on a bar, 11 mm VW3 A5 104 Connected on a tag connector, M10 VW3 A5 105, 106 Connected on a tag connector, M12 VW3 A5 107, 108 Connected on a tag connector, 2 x M12 (1) These values are given for a switching frequency of 2.5 or 4 kHz depending on the rating. (2) Choke performance is ensured by not exceeding the cable lengths between the motor and the drive given in the table above. For an application with several motors connected in parallel, the cable length must include all cabling. If a cable longer than that recommended is used, the motor chokes may overheat. (3) The contact should be connected in the sequence (use for signalling or in line contactor control). Maximum connection capacity VW3 A5 101, 102 and tightening torque VW3 A5 103

Catalog numbers: page 84

Dimensions: pages 110 and 111

Wiring diagrams: page 124

Global Catalog. Refer to Statement of Scope on page 2.

83

Catalog numbers

Variable speed drives for asynchronous motors


Altivar 71: output filters
Options: motor chokes

Motor chokes
For drives Maximum motor cable length Shielded Unshielded m m 150 200 300 ATV 71HD11M3XHD22M3X ATV 71HD30M3XHD45M3X VW3 A5 101 ATV 71HD55M3X, HD75M3X 150 150 150 300 260 300 300 300 300 Loss Nominal Catalog number Weight current A 12 48 90 90 VW3 A5 101 VW3 A5 102 VW3 A5 103 VW3 A5 103 kg 5.500 8.000 10.000 10.000 17.300 29.600

W 150 250 350 350 430 475

3-phase supply voltage: 200240 V 50/60 Hz


ATV 71H037M3HU22M3 ATV 71HU30M3HU75M3

3 x 215 VW3 A5 104 (1) 3 x 314 VW3 A5 105 (1)

3-phase supply voltage: 380480 V 50/60 Hz


ATV 71H075N4HU40N4 75 85 160 ATV 71HU55N4HD18N4 85 160 200 ATV 71HD22N4HD30N4 140 150 ATV 71HD37N4 97 200 ATV 71HD45N4HD75N4 ATV 71HD90N4 ATV 71HC11N4, HC13N4 ATV 71HC16N4HC20N4 ATV 71HC25N4 Motor P 220 kW Motor P 250 kW ATV 71HC28N4, HC31N4 ATV 71HC40N4 Motor P 355 kW Motor P 400 kW ATV 71HC50N4 (1) 3 single-phase chokes are included with the drive. 150 200 150 250 250 200 200 200 250 250 90 95 200 95 200 300 170 300 166 300 300 300 250 300 300 250 250 250 300 300 150 250 350 250 350 430 350 430 350 430 430 430 475 530 530 598 598 598 682 682 12 48 90 48 90 VW3 A5 101 VW3 A5 102 VW3 A5 103 VW3 A5 102 VW3 A5 103 5.500 8.000 10.000 8.000 10.000 17.300 10.000 17.300 10.000 17.300 17.300 17.300 29.600 44.400 44.400 64.500 64.500 64.500 99.200 99.200

3 x 215 VW3 A5 104 (1) 90 VW3 A5 103

3 x 215 VW3 A5 104 (1) 90 VW3 A5 103

3 x 215 VW3 A5 104 (1) 3 x 215 VW3 A5 104 (1) 3 x 215 VW3 A5 104 (1) 3 x 314 VW3 A5 105 (1) 3 x 481 VW3 A5 106 (1) 3 x 481 VW3 A5 106 (1) 3 x 759 VW3 A5 107 (1) 3 x 759 VW3 A5 107 (1) 3 x 759 VW3 A5 107 (1) 3 x 1188 VW3 A5 108 (1) 3 x 1188 VW3 A5 108 (1)

Presentation: page 82

Characteristics: page 83

Dimensions: pages 110 and 111

Wiring diagrams: page 124

84

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers (continued)

Variable speed drives for asynchronous motors


Altivar 71: output filters
Options: motor chokes

IP 20 protection kits
Description For filters Catalog number VW3 A9 612 Mechanical kit including an VW3 A5 104, 105 IP 20 cover and cable clamps VW3 A5 106108 Weight kg

VW3 A9 613

Presentation: page 82

Characteristics: page 83

Catalog numbers: page 84

Dimensions: page 111

Wiring diagrams: page 124

Global Catalog. Refer to Statement of Scope on page 2.

85

Presentation, characteristics

Variable speed drives for asynchronous motors


Altivar 71: output filters
Options: sinusoidal filters

Sinusoidal filters
Sinusoidal filters allow Altivar 71 drives to operate with longer motor cables (up to 1000 m). For ATV 71pppM3, ATV 71H037M3X...HU45M3X, ATV 71H075N4... HD75N4 drives, it also enables the use of unshielded cables while still complying with the standards on radiated EMC emissions (EN55011 class A Gr1). Applications Applications requiring: b Long cable runs b Mechanical restrictions preventing the use of shielded cables b An intermediate transformer between the drive and the motor b Motors connected in parallel

Altivar 71

M1 3

Sinusoidal filter

General characteristics
Type of choke Degree of protection Atmospheric pollution Degree of pollution Vibration resistance Shock resistance Maximum relative humidity Ambient air temperature around the device VW3 A5 201206 VW3 A5 207211 IP 20 IP 00 3C2, 3B1, 3S1 conforming to IEC 721.3.3 2 conforming to standard EN 50178 1.5 mm from 3...13 Hz, 1 gn from 13...200 Hz, conforming to IEC 60068-2 15 gn for 11 ms conforming to IEC 60068-2-27 95% - 10...+ 40 without derating From 40...50C with current derating of 1.5% per additional C - 40 65 + 1000 without derating From 10003000 with current derating of 1% per additional 100 m 4...8 0...100 < 10% a 500 1.5 x nominal current for 60 s 600 or 1000 depending on the drive rating, see page 82

Operation Storage

C C m kHz Hz V

Maximum operating altitude Switching frequency Output frequency Voltage drop Maximum voltage Maximum current Maximum length of motor cable

Unshielded cable

Connection characteristics
Maximum connection capacity VW3 A5 201 and tightening torque VW3 A5 202 VW3 A5 203 VW3 A5 204 VW3 A5 205 VW3 A5 206, 207 VW3 A5 208, 209 VW3 A5 210 VW3 A5 211 4 mm2 (AWG 10) 0.6 Nm 6 mm2 (AWG 8) 1.5 Nm 10 mm2 (AWG 6) 1.5 Nm 25 mm2 (AWG 2) 4 Nm 50 mm2 (AWG 0) 6 Nm 95 mm2 (AWG 4/0) 20 Nm Connected on a bar, 11 mm Connected on a bar, 14 mm Connected on a bar, 4 x 11 mm

Catalog numbers: page 87

Dimensions: pages 112 and 113

Wiring diagrams: page 124

86

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers

Variable speed drives for asynchronous motors


Altivar 71: output filters
Options: sinusoidal filters

Sinusoidal filters
For drives Nominal current A 11 16 33 66 95 180 300 Loss at 100 Hz W 50 70 120 180 250 400 1360 Catalog number Weight kg VW3 A5 201 VW3 A5 202 VW3 A5 203 VW3 A5 204 VW3 A5 205 VW3 A5 206 VW3 A5 208 8.000 11.000 22.000 45.000 60.000 120.000 165.000

3-phase supply voltage: 200 240 V 50/60 Hz


ATV 71H037M3...HU15M3 (1) ATV 71HU22M3, HU30M3 ATV 71HU40M3... HU75M3 ATV 71HD11M3X, HD15M3X ATV 71HD18M3X, HD22M3X ATV 71HD30M3X... HD45M3X ATV 71HD55M3X, HD75M3X

3-phase supply voltage: 380 480 V 50/60 Hz


ATV 71H075N4...HU40N4 (1) ATV 71HU55N4 ATV 71HU75N4...HD15N4 ATV 71HD18N4... HD30N4 ATV 71HD37N4, HD45N4 ATV 71HD55N4, HD75N4 ATV 71 HD90N4, HC11N4 ATV 71 HC13N4, HC16N4 ATV 71 HC20N4 ATV 71 HC25N4 Motor P 350 hp (220 kW) Motor P 400 hp (250 kW) 11 16 33 66 95 180 200 300 400 400 600 600 Motor P 355 kW Motor P 600 hp (400 kW) ATV 71 HC50N4 600 1200 1200 50 70 120 180 250 400 945 1360 1900 1900 2370 2370 2370 5150 5150 VW3 A5 201 VW3 A5 202 VW3 A5 203 VW3 A5 204 VW3 A5 205 VW3 A5 206 VW3 A5 207 VW3 A5 208 VW3 A5 209 VW3 A5 209 VW3 A5 210 VW3 A5 210 VW3 A5 210 VW3 A5 211 VW3 A5 211 8.000 11.000 22.000 45.000 60.000 120.000 130.000 165.000 190.000 190.000 260.000 260.000 260.000 600.000 600.000

ATV 71 HC28N4, HC31N4 ATV 71 HC40N4

(1)For ATV 71H037M3HU15M3 and ATV 71H075N4HU22N4 drives, it is advisable to use a lower category of motor with a sinusoidal filter.

Presentation: page 86

Characteristics: page 86

Dimensions: pages 112 and 113

Wiring diagrams: page 124

Global Catalog. Refer to Statement of Scope on page 2.

87

Combinations

Variable speed drives for asynchronous motors


Altivar 71

Table showing possible combinations of Altivar 71 drive options


Motor Drive Options DC choke Line choke Additional EMC input filter Motor choke IP 20 motor choke kit

kW
0.37 0.75 1.5 2.2 3 4 5.5 0.37 0.75 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75

HP
0.5 1 2 3 5 7.5 0.5 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 ATV 71H075M3 ATV 71HU15M3 ATV 71HU22M3 ATV 71HU30M3 ATV 71HU40M3 ATV 71HU55M3 ATV 71HU75M3 ATV 71H037M3 ATV 71H075M3 ATV 71HU15M3 ATV 71HU22M3 ATV 71HU30M3 ATV 71HU40M3 ATV 71HU55M3 ATV 71HU75M3 ATV 71HD11M3X ATV 71HD15M3X ATV 71HD18M3X ATV 71HD22M3X ATV 71HD30M3X ATV 71HD37M3X ATV 71HD45M3X ATV 71HD55M3X ATV 71HD75M3X VW3 A4 503 VW3 A4 505 VW3 A4 506 VW3 A4 507 VW3 A4 508 VW3 A4 508 VW3 A4 509 VW3 A4 501 VW3 A4 503 VW3 A4 505 VW3 A4 506 VW3 A4 507 VW3 A4 508 VW3 A4 508 VW3 A4 509 VW3 A4 510 VW3 A4 510 VW3 A4 511 VW3 A4 511 VW3 A4 512 VW3 A4 512 VW3 A4 512 VW3 A4 551 VW3 A4 552 VW3 A4 552 VW3 A4 553 VW3 A4 554 VW3 A4 554 VW3 A4 555 VW3 A4 551 VW3 A4 551 VW3 A4 552 VW3 A4 552 VW3 A4 553 VW3 A4 554 VW3 A4 554 VW3 A4 555 VW3 A4 555 VW3 A4 556 VW3 A4 557 VW3 A4 557 VW3 A4 557 VW3 A4 557 VW3 A4 557 VW3 A4 562 VW3 A4 563 VW3 A4 401 VW3 A4 401 VW3 A4 402 VW3 A4 402 VW3 A4 402 VW3 A4 403 VW3 A4 404 VW3 A4 401 VW3 A4 401 VW3 A4 401 VW3 A4 402 VW3 A4 402 VW3 A4 402 VW3 A4 403 VW3 A4 404 VW3 A4 405 VW3 A4 405 VW3 A4 406 VW3 A4 406 VW3 A4 408 VW3 A4 408 VW3 A4 408 VW3 A4 401 VW3 A4 401 VW3 A5 101 VW3 A5 101 VW3 A5 101 VW3 A5 102, 103 VW3 A5 102, 103 VW3 A5 102, 103 VW3 A5 102, 103 VW3 A5 101 VW3 A5 101 VW3 A5 101 VW3 A5 101 VW3 A5 102, 103 VW3 A5 102, 103 VW3 A5 102, 103 VW3 A5 102, 103 VW3 A5 103 VW3 A5 103 VW3 A5 103 VW3 A5 103 VW3 A5 104 VW3 A5 104 VW3 A5 104 VW3 A5 105 VW3 A5 105 VW3 A9 612 VW3 A9 612 VW3 A9 612 VW3 A9 612 VW3 A9 612

Single phase supply voltage: 200240 V 50/60 Hz

3-phase supply voltage: 200240 V 50/60 Hz

Pages

20

71

74

80

84

85

Table showing possible combinations of options common to all Altivar 71 drives


For drives Logic input I/O cards (1) adaptor Logic a 115 V Extended Programmable "Controller Inside" card
VW3 A3 501

Remote graphic display terminal

Encoder interface cards RS 422 Open compatible collector differential outputs outputs
VW3 A3 401, 402 VW3 A3 403, 404

Push-pull outputs

PowerSuite software workshop for PC and Pocket PC


VW3 A8 104, 105

ATV 71Hppppp

VW3 A3 101 VW3 A3 201

VW3 A3 202

VW3 A1 101

VW3 A3 405 407

Pages

22

33

33

41

28

31

31

31

181

(1) Maximum combination: 2 cards, in accordance with the compatibility table below: Communication Programmable Controller Type of card VW3 A3 3pp inside VW3 A3 501 Communication VW3 A3 3pp Programmable Controller inside VW3 A3 501 Logic I/O VW3 A3 201 Extended I/O VW3 A3 202 Possible to combine Not possible to combine

Logic I/O VW3 A3 201

Extended I/O VW3 A3 202

88

Global Catalog. Refer to Statement of Scope on page 2.

Sinusoidal filter

Braking resistor

Hoist resistor

Flushmounting kit (inside dust and damp proof enclosure)


VW3 A9 501 VW3 A9 501 VW3 A9 502 VW3 A9 502 VW3 A9 502 VW3 A9 503 VW3 A9 504 VW3 A9 501 VW3 A9 501 VW3 A9 501 VW3 A9 502 VW3 A9 502 VW3 A9 502 VW3 A9 503 VW3 A9 504 VW3 A9 505 VW3 A9 505 VW3 A9 506 VW3 A9 506 VW3 A9 508 VW3 A9 508 VW3 A9 508 VW3 A9 510 VW3 A9 511

NEMA Type 1 conformity kit (outside enclosure)

IP 21 or IP 31 conformity kit (outside enclosure)

Control card fan kit

VW3 A5 201 VW3 A5 201 VW3 A5 202 VW3 A5 202 VW3 A5 203 VW3 A5 203 VW3 A5 203 VW3 A5 201 VW3 A5 201 VW3 A5 201 VW3 A5 202 VW3 A5 202 VW3 A5 203 VW3 A5 203 VW3 A5 203 VW3 A5 204 VW3 A5 204 VW3 A5 205 VW3 A5 205 VW3 A5 206 VW3 A5 206 VW3 A5 206 VW3 A5 208 VW3 A5 208

VW3 A7 701 VW3 A7 702 VW3 A7 702 VW3 A7 703 VW3 A7 703 VW3 A7 704 VW3 A7 704 VW3 A7 701 VW3 A7 701 VW3 A7 702 VW3 A7 702 VW3 A7 703 VW3 A7 703 VW3 A7 704 VW3 A7 704 VW3 A7 705 VW3 A7 706 VW3 A7 707 VW3 A7 707 VW3 A7 708 VW3 A7 709 VW3 A7 709 VW3 A7 713 VW3 A7 714

VW3 A7 801 VW3 A7 802 VW3 A7 803 VW3 A7 803 VW3 A7 803 VW3 A7 804 VW3 A7 804 VW3 A7 801 VW3 A7 801 VW3 A7 802 VW3 A7 803 VW3 A7 803 VW3 A7 803 VW3 A7 804 VW3 A7 804 VW3 A7 805 VW3 A7 805 VW3 A7 806 VW3 A7 807 VW3 A7 807 VW3 A7 808 VW3 A7 808 VW3 A7 809 VW3 A7 810

VW3 A9 201 VW3 A9 201 VW3 A9 202 VW3 A9 202 VW3 A9 202 VW3 A9 203 VW3 A9 204 VW3 A9 201 VW3 A9 201 VW3 A9 201 VW3 A9 202 VW3 A9 202 VW3 A9 202 VW3 A9 203 VW3 A9 204 VW3 A9 205 VW3 A9 205 VW3 A9 206 VW3 A9 206 VW3 A9 208 VW3 A9 208 VW3 A9 208 VW3 A9 209 VW3 A9 210

VW3 A9 101 VW3 A9 101 VW3 A9 102 VW3 A9 102 VW3 A9 102 VW3 A9 103 VW3 A9 104 VW3 A9 101 VW3 A9 101 VW3 A9 101 VW3 A9 102 VW3 A9 102 VW3 A9 102 VW3 A9 103 VW3 A9 104 VW3 A9 105 VW3 A9 105 VW3 A9 106 VW3 A9 106 VW3 A9 108 VW3 A9 108 VW3 A9 108 VW3 A9 109 VW3 A9 110

VW3 A9 406 VW3 A9 406

87

53

55

23

24

25

22

Communication cards (1) Ethernet Modbus/ TCP/IP Uni-Telway

Fipio standard Substitution Fipio

Modbus Plus

Profibus DP

DeviceNet

INTERBUS

VW3 A3 310

VW3 A3 303

VW3 A3 311

VW3 A3 301

VW3 A3 302

VW3 A3 307

VW3 A3 309

VW3 A3 304

48 and 186

48, 193 and 201

48 and 190

48 and 190

48 and 198

48

48

48

Global Catalog. Refer to Statement of Scope on page 2.

89

Combinations (continued)

Variable speed drives for asynchronous motors


Altivar 71

Table showing possible combinations of Altivar 71 drive options


Motor Drive Option DC choke Line choke Passive filter (1) Additional EMC input filter IP 30 EMC filter kit Motor choke IP 20 motor choke kit

kW
0.75 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 220 250 280 315 355 400 500

HP
1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400 450 500 600 700 ATV 71H075N4 ATV 71HU15N4 ATV 71HU22N4 ATV 71HU30N4 ATV 71HU40N4 ATV 71HU55N4 ATV 71HU75N4 ATV 71HD11N4 ATV 71HD15N4 ATV 71HD18N4 ATV 71HD22N4 ATV 71HD30N4 ATV 71HD37N4 ATV 71HD45N4 ATV 71HD55N4 ATV 71HD75N4 ATV 71HD90N4 ATV 71HC11N4 ATV 71HC13N4 ATV 71HC16N4 ATV 71HC20N4 ATV 71HC25N4 ATV 71HC25N4 ATV 71HC28N4 ATV 71HC31N4 ATV 71HC40N4 ATV 71HC40N4 ATV 71HC50N4 VW3 A4 501 VW3 A4 502 VW3 A4 503 VW3 A4 503 VW3 A4 504 VW3 A4 505 VW3 A4 506 VW3 A4 507 VW3 A4 508 VW3 A4 508 VW3 A4 510 VW3 A4 510 VW3 A4 510 VW3 A4 511 VW3 A4 511 VW3 A4 511 VW3 A4 551 VW3 A4 551 VW3 A4 552 VW3 A4 552 VW3 A4 552 VW3 A4 553 VW3 A4 553 VW3 A4 554 VW3 A4 554 VW3 A4 555 VW3 A4 555 VW3 A4 556 VW3 A4 556 VW3 A4 556 VW3 A4 556 VW3 A4 557 VW3 A4 558 VW3 A4 559 VW3 A4 560 VW3 A4 561 VW3 A4 562 VW3 A4 562 VW3 A4 563 VW3 A4 564 VW3 A4 564 VW3 A4 565 VW3 A4 566 VW3 A4 567 VW3 A4 6p1 VW3 A4 6p1 VW3 A4 6p1 VW3 A4 6p2 VW3 A4 6p2 VW3 A4 6p3 VW3 A4 6p3 VW3 A4 6p4 VW3 A4 6p5 VW3 A4 6p6 VW3 A4 6p6 VW3 A4 6p7 VW3 A4 6p7 VW3 A4 6p8 VW3 A4 6p8 VW3 A4 6p9 VW3 A4 6p9 VW3 A4 6p0 VW3 A4 6p1 VW3 A4 6p2 VW3 A4 6p3 VW3 A4 6p3 VW3 A4 6p4 VW3 A4 6p5 VW3 A4 6p5 VW3 A4 6p5 VW3 A4 6p6 VW3 A4 6p7 VW3 A4 401 VW3 A4 401 VW3 A4 401 VW3 A4 402 VW3 A4 402 VW3 A4 403 VW3 A4 403 VW3 A4 404 VW3 A4 405 VW3 A4 405 VW3 A4 406 VW3 A4 407 VW3 A4 407 VW3 A4 408 VW3 A4 408 VW3 A4 408 VW3 A4 410 VW3 A4 410 VW3 A4 410 VW3 A4 411 VW3 A4 411 VW3 A4 411 VW3 A4 411 VW3 A4 411 VW3 A4 412 VW3 A4 412 VW3 A4 412 VW3 A4 413 VW3 A9 601 VW3 A9 601 VW3 A9 601 VW3 A9 601 VW3 A9 601 VW3 A9 601 VW3 A9 601 VW3 A9 601 VW3 A9 602 VW3 A9 602 VW3 A9 602 VW3 A9 602 VW3 A5 10p VW3 A5 10p VW3 A5 10p VW3 A5 10p VW3 A5 10p VW3 A5 10p VW3 A5 10p VW3 A5 10p VW3 A5 10p VW3 A5 10p VW3 A5 10p VW3 A5 10p VW3 A5 10p VW3 A5 104 VW3 A5 104 VW3 A5 104 VW3 A5 104 VW3 A5 105 VW3 A5 105 VW3 A5 106 VW3 A5 106 VW3 A5 106 VW3 A5 107 VW3 A5 107 VW3 A5 107 VW3 A5 107 VW3 A5 108 VW3 A5 108 VW3 A9 612 VW3 A9 612 VW3 A9 612 VW3 A9 612 VW3 A9 612 VW3 A9 612 VW3 A9 612 VW3 A9 612 VW3 A9 612 VW3 A9 612 VW3 A9 612 VW3 A9 612 VW3 A9 612 VW3 A9 612 VW3 A9 613 VW3 A9 613 VW3 A9 613 VW3 A9 613 VW3 A9 613 VW3 A9 613 VW3 A9 613 VW3 A9 613 VW3 A9 613

3-phase supply voltage: 380480 V 50/60 Hz

Pages

20

71

74

76

80

81

84

85

Table showing possible combinations of options common to all Altivar 71 drives


For drives Logic input I/O cards (2) adaptor Logic a 115 V Extended Programmable "Controller Inside" card
VW3 A3 501

Remote graphic display terminal

Encoder interface cards RS 422 Open compatible collector differential outputs outputs
VW3 A3 401, 402 VW3 A3 403, 404

Push-pull outputs

PowerSuite software workshop for PC and Pocket PC


VW3 A8 104, 105

ATV 71Hppppp

VW3 A3 101 VW3 A3 201

VW3 A3 202

VW3 A1 101

VW3 A3 405 407

Pages

22

33

33

41

28

31

31

31

181

(1) There are special passive filters for a a 460 V supply , see page 77. (2) Maximum combination: 2 cards, in accordance with the compatibility table below: Communication Programmable Controller Type of card VW3 A3 3pp inside VW3 A3 501 Communication VW3 A3 3pp Programmable Controller inside VW3 A3 501 Logic I/O VW3 A3 201 Extended I/O VW3 A3 202 Possible to combine Not possible to combine

Logic I/O VW3 A3 201

Extended I/O VW3 A3 202

90

Global Catalog. Refer to Statement of Scope on page 2.

Sinusoidal filter

Resistance braking unit

Braking resistor

Hoist resistor

Flushmounting kit (inside dust and damp proof enclosure)


VW3 A9 501 VW3 A9 501 VW3 A9 501 VW3 A9 502 VW3 A9 502 VW3 A9 503 VW3 A9 503 VW3 A9 504 VW3 A9 505 VW3 A9 505 VW3 A9 506 VW3 A9 507 VW3 A9 507 VW3 A9 509 VW3 A9 509 VW3 A9 509 VW3 A9 510 VW3 A9 511 VW3 A9 512 VW3 A9 513 VW3 A9 514, 515 VW3 A9 514, 515 VW3 A9 514, 515 VW3 A9 514, 515 VW3 A9 516 VW3 A9 516 VW3 A9 516 VW3 A9 517

NEMA Type 1 conformity kit (outside enclosure)

IP 21 or IP 31 conformity kit (outside enclosure)

Control card fan kit

VW3 A5 201 VW3 A5 201 VW3 A5 201 VW3 A5 201 VW3 A5 201 VW3 A5 202 VW3 A5 203 VW3 A5 203 VW3 A5 203 VW3 A5 204 VW3 A5 204 VW3 A5 204 VW3 A5 205 VW3 A5 205 VW3 A5 206 VW3 A5 206 VW3 A5 207 VW3 A5 207 VW3 A5 208 VW3 A5 208 VW3 A5 209 VW3 A5 209 VW3 A5 210 VW3 A5 210 VW3 A5 210 VW3 A5 210 VW3 A5 211 VW3 A5 211

VW3 A7 101 VW3 A7 101 VW3 A7 101 VW3 A7 101 VW3 A7 102 VW3 A7 102 VW3 A7 102 VW3 A7 102

VW3 A7 701 VW3 A7 701 VW3 A7 701 VW3 A7 701 VW3 A7 701 VW3 A7 702 VW3 A7 702 VW3 A7 703 VW3 A7 703 VW3 A7 704 VW3 A7 704 VW3 A7 704 VW3 A7 705 VW3 A7 707 VW3 A7 707 VW3 A7 707 VW3 A7 710 VW3 A7 711 VW3 A7 711 VW3 A7 712 VW3 A7 715 VW3 A7 716 VW3 A7 716 VW3 A7 716 VW3 A7 717 VW3 A7 717 VW3 A7 717 VW3 A7 718

VW3 A7 801 VW3 A7 801 VW3 A7 801 VW3 A7 802 VW3 A7 802 VW3 A7 803 VW3 A7 803 VW3 A7 803 VW3 A7 804 VW3 A7 804 VW3 A7 804 VW3 A7 804 VW3 A7 805 VW3 A7 805 VW3 A7 805 VW3 A7 806 VW3 A7 811 VW3 A7 812 VW3 A7 812 VW3 A7 813 VW3 A7 814 VW3 A7 815 VW3 A7 815 VW3 A7 815 VW3 A7 816 VW3 A7 816 VW3 A7 816 VW3 A7 817

VW3 A9 201 VW3 A9 201 VW3 A9 201 VW3 A9 202 VW3 A9 202 VW3 A9 203 VW3 A9 203 VW3 A9 204 VW3 A9 205 VW3 A9 205 VW3 A9 206 VW3 A9 207 VW3 A9 207 VW3 A9 208 VW3 A9 208 VW3 A9 208 VW3 A9 209 VW3 A9 210 VW3 A9 211 VW3 A9 212 VW3 A9 213, 214 VW3 A9 213, 214 VW3 A9 213, 214 VW3 A9 213, 214 VW3 A9 215 VW3 A9 215 VW3 A9 215 VW3 A9 216

VW3 A9 101 VW3 A9 101 VW3 A9 101 VW3 A9 102 VW3 A9 102 VW3 A9 103 VW3 A9 103 VW3 A9 104 VW3 A9 105 VW3 A9 105 VW3 A9 106 VW3 A9 107 VW3 A9 107 VW3 A9 108 VW3 A9 108 VW3 A9 108 VW3 A9 109 VW3 A9 110 VW3 A9 111 VW3 A9 112 VW3 A9 113, 114 VW3 A9 113, 114 VW3 A9 113, 114 VW3 A9 113, 114 VW3 A9 115 VW3 A9 115 VW3 A9 115 VW3 A9 116

VW3 A9 406 VW3 A9 406 VW3 A9 406 VW3 A9 407 VW3 A9 407 VW3 A9 407

87

51

53

55

23

24

25

22

Communication cards (2) Ethernet Modbus/ TCP/IP Uni-Telway

Fipio standard Substitution Fipio

Modbus Plus

Profibus DP

DeviceNet

INTERBUS

VW3 A3 310

VW3 A3 303

VW3 A3 311

VW3 A3 301

VW3 A3 302

VW3 A3 307

VW3 A3 309

VW3 A3 304

48 and 186

48, 193 and 201 48 and 190

48 and 190

48 and 198

48

48

48

Global Catalog. Refer to Statement of Scope on page 2.

91

Dimensions

Variable speed drives for asynchronous motors


Altivar 71
Drives

ATV 71HpppM3, ATV 71HD11M3X, HD15M3X, ATV 71H075N4...HD18N4


Without option card 1 option card (1) 2 option cards (1) Common front view
K b 4x c c1 c2 = G a

ATV 71H a 037M3...U15M3, 075N4...U22N4 130 U22M3...U40M3, U30N4, U40N4 155 U55M3, U55N4, U75N4 175 U75M3, D11N4 210 D11M3X, D15M3X, 230 D15N4, D18N4 Without option card

b 230 260 295 295 400

c 175 187 187 213 213

c1 198 210 210 236 236

c2 221 233 233 259 259

G 113.5 138 158 190 210

H 220 249 283 283 386

K 5 4 6 6 8

5 5 6 6 6

ATV 71HD18M3X45M3X, ATV 71HD22N4HD37N4


1 option card (1) 2 option cards (1) Common front view

H =

4x

c1

c2

G a

ATV 71H D18M3X, D22M3X, D22N4 D30N4, D37N4 D30M3XD45M3X

a 240 240 320

b 420 550 550

c 236 266 266

c1 259 289 289

c2 282 312 312

G 206 206 280

H 403 529 524.5

k 8.5 10 10

6 6 9

ATV 71HD45N4...HD75N4
Without option card 1 option card (1) 2 option cards (1) Common front view

H = 4x9 313 334 = 280 320


Characteristics: pages 10 to 15 Catalog numbers: pages 20 and 21 Wiring diagrams: pages 114 to 129 Functions: pages 144 to 175

K 290
(1) Option cards: I/O extension cards, communication cards or Controller Inside programmable card. Presentation: pages 6 to 9

92

Global Catalog. Refer to Statement of Scope on page 2.

604,5 =

630

10

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Drives

ATV 71HD55M3X, HD75M3X, ATV 71HD90N4...HC28N4


With or without 1 option card (1) 2 option cards (1) Common front view ATV 71HC20N4HC28N4 with braking unit VW3 A7 101

8x c c1 = G = 102,5
ATV 71H a b c c1 G H K D55M3X, 320 920 377 392 250 650 150 D90N4 D75M3X, 360 1022 377 392 298 758 150 C11N4 C13N4 340 1190 377 392 285 920 150 C16N4 440 1190 377 392 350 920 150 C20N4C28N4 595 1190 377 392 540 920 150 (1) Option cards: I/O extension cards, communication cards or Controller Inside programmable card. K1 75 75 75 75 75

K1 K

K2

670

540 27,5
K2 30 30 30 30 30 11.5 11.5 11.5 11.5 11.5

ATV 71HC31N4HC50N4
With or without 1 option card (1) 2 option cards (1) ATV 71HC31N4, HC40N4 Front view ATV 71HC50N4 Front view

a K2 J1 J J1 J1

a J J1

13x c c1 = G G =

H 14x = G G =
ATV 71H C31N4, C40N4 C50N4 a 890 1120 b 1390 1390 c 377 377 c1 392 392 G 417.5 532.5 J 70 70 J1 380 495 H 1120 1120 K 150 150 K1 75 75

K1 K

K2 30 30

11.5 11.5

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Wiring diagrams: pages114 to 129

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

93

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Drives

ATV 71HpppM3Z, ATV 71HD11M3XZ, HD15M3XZ, ATV 71H075N4ZHD15N4Z


Without option card (1) 1 option card (1) 2 option cards (1) Common front view

4x

c1

c2

G a

ATV 71H a b c c1 c2 G H 037M3ZU15M3Z, 130 230 149 172 195 113.5 220 075N4ZU22N4Z U22M3ZU40M3Z, 155 260 161 184 207 138 249 U30N4Z, U40N4Z U55M3Z, 175 295 161 184 207 158 283 U55N4Z, U75N4Z U75M3Z, 210 295 187 210 233 190 283 D11N4Z D11M3XZ, D15M3XZ 230 400 187 210 233 210 386 D15N4Z (1) Option cards: I/O extension cards, communication cards or Controller Inside programmable card.

K 5 4 6 6 8

5 5 6 6 6

ATV 71HD55M3XD, HD75M3XD, ATV 71HD90N4D...HC28N4D


With or without 1 option card (1) 2 option cards (1) Common front view ATV 71HC20N4DHC28N4D with braking unit VW3 A7 101

4x
c1 = G a =

4x

97,5

540 660

H =

22,5

ATV 71H D55M3XD, D90N4D D75M3XD, C11N4D C13N4D C16N4D C20N4DC28N4D

a 310 350 330 430 585

b 680 782 950 950 950

c 377 377 377 377 377

c1 392 392 392 392 392

G 250 298 285 350 540

H 650 758 920 920 920

K 15 12 15 15 15

11.5 11.5 11.5 11.5 11.5

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

94

Global Catalog. Refer to Statement of Scope on page 2.

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Drives, accessories

ATV 71HC31N4DHC50N4D
With or without 1 option card (1) 2 option cards (1) ATV 71HC31N4D, HC40N4D Front view ATV 71HC50N4D Front view

5x c c1 = G a
ATV 71H a b c c1 G H K C31N4D, C40N4D 880 1150 377 392 417.5 1120 15 11.5 C50N4D 1110 1150 377 392 532.5 1120 15 11.5 (1) Option cards: I/O extension cards, communication cards or Controller Inside programmable card.

H 6x G = = G a G =
For ATV 71HD18M3XHD45M3X, ATV 71HD22N4HD75N4 For ATV 71H D18M3X, 22M3X, D22N4D37N4 D30M3XD45M3X D45N4D75N4 M5 M8

EMC mounting plates (1)


For ATV 71HpppM3, ATV 71HD11M3X, HD15M3X, ATV 71H075N4HD18N4

M5 120

(1) Supplied with the drive apart from ATV 71HD55M3X, HD75M3X, ATV 71HD90N4HC50N4. In the case of these drives the mounting plate is supplied with the NEMA Type 1, IP 21 or IP 31 conformity kits, which must be ordered separately, see pages 24 and 25. Dimensions, see page 99.

Control card fan kits


VW3 A9 406, 407 Mounting recommendations

50

Presentation: pages 6 to 9

40

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

u 50

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

95

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Accessories

Kits for flush-mounting inside dust and damp proof enclosure


VW3 A9 501505 Cut-outs and drill holes VW3 A9 506 Cut-outs and drill holes

H1

5,5

13

b1

10x3,6(1) H b 600 649

G1

12x4,5 (1)

a1 a

= G

= 280 340

= 316

VW3 a a1 b b1 A9 501 222 169 398.8 342 A9 502 247 194 425.5 368 A9 503 267 214 463 406 A9 504 302 249 463.9 407 A9 505 322 269 566.8 510 (1) 3.6 hole for M4 self-tapping screw. VW3 A9 507

G 206 230 250 286 304

G1 18.5 18 18 18.5 17.5

H 127 136 149 149 183

H1 19.5 20 20.5 20 19.5 (1) 4.5 hole for M5 self-tapping screw. VW3 A9 508

Cut-outs and drill holes

Cut-outs and drill holes

396 7,5

7,5 18 = 17 132,5 148,5 162 159 132,5

5,5

13

146

146

708,5

719

768

146

18

146

14x4,5 (1)

146

757,5

280 340 = 316 =

7,5

360 420

17

= 362

(1) 4.5 hole for M5 self-tapping screw.

(1) 4.5 hole for M5 self-tapping screw.

Presentation: page 23

Catalog numbers: page 23

Functions: pages 144 to 175

96

Global Catalog. Refer to Statement of Scope on page 2.

13

14x4,5 (1)

153

18

152,75 152,75

153

7,5

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Accessories

Kits for flush-mounting inside dust and damp proof enclosure (continued)
VW3 A9 509 Cut-outs and drill holes VW3 A9 510, 511 Cut-outs and drill holes

396

a 117,5 144,5 145,25 145,25 144,5 117,5 K b2

a1

13

6x10 H b1 b G1 150 a2 = G
VW3 a a1 a2 A9 510 420 340 55 A9 511 440 360 45 VW3 G2 H H1 A9 510 30 260 120 A9 511 23 310 70 (1) For fixing using an M8 screw min. b 850 885 H2 80 91.5 b1 790 845 H3 100 83.5 b2 80 66 H4 15 10 G1 15 18 K 35 27.5

G2

788,5 837,5

6x10 (1)

360 420

17

= 362

17

a2

8x7x12

(1) 4.5 hole for M5 self-tapping screw. VW3 A9 512, 513 Cut-outs and drill holes

a 111

a1

15

30

20

30

1062

970

8x10 (1) 51

8x10

56

6x7x12

56

= G

VW3 a a1 A9 512 442 360 A9 513 542 460 (1) For fixing using an M8 screw min.

G 390 490

Presentation: page 23

Catalog numbers: page 23

Functions: pages 144 to 175

60

280

280

280

120

Global Catalog. Refer to Statement of Scope on page 2.

H1

H2

16x4,5

18

H4

H3

97

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Accessories

Kits for flush-mounting inside dust and damp proof enclosure (continued)
VW3 A9 514, 515 Cut-outs and drill holes

a 111

a1

17,5

30

20

30

1062

970

8x10 (1) 51

8x10

56

8x7x12

56

G1

G1 G

G1

VW3 a a1 G A9 514 697 610 645 A9 515 772 685 720 (1) For fixing using an M8 screw min. VW3 A9 516, 517

G1 215 240

Cut-outs and drill holes

a 111

a1

60

280

280

280

120

15

30

20

30

1262

1170

8x12 (1) 51

8x12

56

10x7x12

56

G1

G2 G

G2

G1

VW3 a a1 G A9 516 992 910 940 A9 517 1222 1140 1170 (1) For fixing using an M10 screw min.

G1 235 285

G2 235 300

Presentation: page 23

Catalog numbers: page 23

Functions: pages 144 to 175

98

Global Catalog. Refer to Statement of Scope on page 2.

60

350

340

350

120

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Accessories

NEMA Type 1, IP 21 (VW3 A9 2pp) or IP 31 (VW3 A9 1pp) conformity kits


VW3 A9 101105, 201205 VW3 A9 106108, 206208

c b

a b

a
VW3 A9 101, 201 A9 102, 202 A9 103, 203 A9 104, 204 A9 105, 205 a 130 155 175 210 230 b 113 103 113 113 108 VW3 A9 109113, 115, VW3 A9 209213, 215 VW3 A9 106, 206 A9 107, 207 A9 108, 208 a 240 240 320 b 185 180 178

VW3 A9 109116, VW3 A9 209216

VW3 A9 114, 214

VW3 A9 116, 216

K2

4x

4x 8x

K1

G a

G1 a

G2

J1

J a

J1

VW3 A9 109, 209 A9 110, 210 A9 111, 211 A9 112, 212 A9 113, 213 A9 114, 214 A9 115, 215 A9 116, 216

a 320 360 340 440 595 670 890 1120

b 220 300 315 375 375 375 475 475

c 377 377 377 377 377 377 477 477

G 250 298 285 350 540 540 835

G1 102.5

G2 27.5

K 95 172 250 250 250 250 350 350

K1 65 65 65 65 65 65 65 65

K2 75 75 75 75 75 75 75 75

11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5

J 70

J1 495

Presentation: pages 24 and 25

Characteristics: pages 10 to 15

Catalog numbers: pages 24 and 25

Wiring diagrams: pages 114 to 129

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

99

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Accessories, braking units

Remote graphic display terminal


IP 54 kit VW3 A1 102 Cut-outs and drill holes

35,2

12 6,5
115 = 104 = 5 4x3,5

162,1

144,3

IP 65 kit VW3 A1 103

35,2

21,6 14,3

162,1

Braking unit VW3 A7 102


377 4x11,5 310

Presentation: pages 28 and 50

1150

144,3

Characteristics: page 50

Catalog numbers: pages 28 and 51

114,5
Wiring diagrams: pages 120 and 126

100

Functions: pages 144 to 175

100

Global Catalog. Refer to Statement of Scope on page 2.

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Braking resistors

Braking resistors
VW3 A7 701703 Mounting recommendations

4x

a u 50 u 100 H u 50 u 100 u 50 u 100 u 100

c
VW3 A7 701 A7 702 A7 703 a 95 95 140

G
b 293 293 393 c 95 95 120 G 70 70 120 H 275 375 375 6 x 12 6 x 12 6 x 12

VW3 A7 704709 Mounting recommendations

4x9

240 u 200

484

380

u 200

301

200

Presentation: page 52

Characteristics: page 52

Catalog numbers: page 53

u 200

Wiring diagrams: page 120

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

u 50

101

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Braking resistors

Braking resistors (continued)


VW3 A7 710712, 715718 (1) Mounting recommendations

a1

c1

u 500

u 500

u 500

4x13

H a

G c

VW3 a a1 b c c1 G H A7 710 860 1040 690 480 560 400 832 A7 711 960 1140 1150 380 460 300 932 A7 712 860 1040 1150 540 620 460 832 A7 715 960 1140 1150 540 620 460 932 A7 716 960 1140 1150 740 820 660 932 A7 717 (1) 960 1140 1150 540 620 460 932 A7 718 (1) 960 1140 1150 740 820 660 932 (1) The dimension is given for 1 component. Catalog numbers VW3 A7 717 and 718 consist of two components; all components must be taken into account to determine the overall dimensions. A space of 300 mm must be left between each component. VW3 A7 713, 714 Mounting recommendations

u 500

a1

c1

u 500

u 500

4x13

H a

G c

VW3 A7 713 A7 714

a 760 960

a1 790 990

b 440 440

c 480 480

c1 540 540

G 400 400

H 732 932

Presentation: page 52

Characteristics: page 52

Catalog numbers: page 53

Wiring diagrams: page 120

Functions: pages 144 to 175

102

Global Catalog. Refer to Statement of Scope on page 2.

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Hoist resistors

Hoist resistors
VW3 A7 801804, 807809 Mounting recommendations

u 500

a1

c1

u 500

u 500

4x

H a

G c

VW3 A7 801 A7 802 A7 803 A7 804 A7 807 A7 808 A7 809

a 490 420 580 960 860 860 860

a1 452 450 610 990 890 890 890

b 203.5 440 440 440 440 690 690

c 153 480 480 480 480 480 480

c1 202 540 540 540 540 540 450

G 95 400 400 400 400 400 400

H 470 392 552 932 832 832 832

10 13 13 13 13 13 13

VW3 A7 805, 806, 810817 (1) Mounting recommendations

a1

c1

u 500

u 500

u 500

4x13

H a

G c

VW3 a a1 b c c1 G H A7 805 860 1040 1150 540 620 460 832 A7 806 860 1040 1150 740 820 660 832 A7 810 860 1040 1150 540 620 460 832 A7 811 960 1140 1150 540 620 460 932 A7 812 960 1140 1150 740 820 660 932 A7 813 (1) 960 1140 1150 540 620 460 932 A7 814 (1) 960 1140 1150 540 620 460 932 A7 815 (1) 960 1140 1150 740 820 660 932 A7 816 (1) 960 1140 1150 740 820 660 932 A7 817 (1) 960 1140 1700 740 820 660 932 (1) The dimension is given for 1 component. Catalog numbers VW3 A7 813815 consist of 2 components and catalog numbers VW3 A7 816 and 817 consist of 3 components; all components must be taken into account to determine the overall dimensions. A space of 300 mm must be left between each component.

Presentation: page 54

Characteristics: page 54

Catalog numbers: page 55

Wiring diagrams: page 120

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

103

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Network braking units

Network braking units


VW3 A7 201205, 231, 232 Mounting recommendations

4x
u 70 u 70

VW3 A7 201, 202 A7 203205, A7 231232

a 270 270

b 500 580

c 295 295

G 260 260

H 260 340

H1 80 80

7 7

VW3 A7 206208, 233237 Mounting recommendations

H2

4x

u 150

u 150

H1

u 150

u 70

u 70

G a

VW3 a b c G H H1 A7 206208 245 700 272 260 440 80 A7 233237 272 700 295 260 440 80

H2 180 7 180 7

Presentation: page 64

Characteristics: page 64

H1 =

H b

Catalog numbers: page 65

Wiring diagrams: page 125

Functions: pages 144 to 175

104

Global Catalog. Refer to Statement of Scope on page 2.

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Network braking units

Network braking units (continued)


VW3 A7 209, 210, 238, 239 Mounting recommendations

2x8,5

4x8,5 837

280

u 150

395

350 380

VW3 A7 211, 212, 240, 241 Mounting recommendations

80

320

u 70

u 70

2x

4x b

H2

u 150

937

u 70

u 70

G a

VW3 A7 211, 240 A7 212, 241

a b c G H H1 380 937 395 350 320 80 380 1037 395 350 320 80

H2 280 8.5 280 8.5

Presentation: page 64

Characteristics: page 64

H1 =

Catalog numbers: page 65

Wiring diagrams: page 125

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

105

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
DC chokes, line chokes

DC chokes
VW3 A4 501510 VW3 A4 511, 512

4x7 c c1
VW3 A4 501 A4 502 A4 503 A4 504 A4 505 A4 506 A4 507 A4 508 A4 509 A4 510 a 60 60 96 96 96 96 96 108 96 126 b 103 103 134 134 134 134 134 142 134 171 c 60 77 80 79 85 89 99 112 89 120 c1 95 118 115 115 120 120 130 145 120 170 G 50 50 80 80 80 80 80 90 80 105 H 51 68 65 64 70 74 84 97 74 103 3.5 3.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 7 VW3 A4 556

222 240 14

48

75

217 280

18

Line chokes
VW3 A4 551555

8x H c c1
VW3 a A4 551 100 A4 552, 553 130 A4 554 155 A4 555 180 VW3 A4 557 b 135 155 170 210 c 55 85 115 125 c1 60 90 135 165 G 40 60 75 85

8x11x22 100 180 105 181 270


G1 60 80.5 107 122 H 42 62 90 105 6x9 6 x 12 6 x 12 6 x 12 VW3 A4 558567 (1)

G G1 a

50

(2)

290 b1 H 2 1 G a
Wiring diagrams: pages 116 to 119

210

8x11x22 G1 c1 c

142 240

190 230 320

VW3 a b b1 c c1 G G1 H 1 2 A4 558 280 305 240 210 200 200 125 275 9 9 9 A4 559 280 330 260 210 200 200 125 300 11 9 9 A4 560, 561 320 380 300 210 200 225 150 350 11 9 9 A4 562564 320 380 300 250 230 225 150 350 13 11 11 A4 565 385 440 340 275 250 300 125 400 2 x 13 13 13 A4 566, 567 (1) 320 380 300 250 230 225 150 350 13 11 11 (1) The dimension is given for 1 component. Catalog numbers VW3 A4 566 and 567 consist of two components; all components must be taken into account to determine the overall dimensions. (2) 25 mm minimum. Presentation: pages 68 and 72 Characteristics: pages 70 and 73 Catalog numbers: pages 71 and 74 Functions: pages 144 to 175

106

Global Catalog. Refer to Statement of Scope on page 2.

191

4x

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Passive filters

Passive filters
VW3 A4 601604, 621, 622, 641644, 661663

135 165

242

416 440

VW3 A4 605609, 623627, 645648, 664666

c H

G a

VW3 A4 605, 606, 623625, 645, 646, 664, 665 A4 607609, 626, 627, 647, 648, 666 VW3 A4 610617, 628637, 649655, 667675 (1)

a 600 840

b 220 220

c 302 302

H 333.5 333.5

G 532.5 772.5

VW3 a b c A4 610, 611, 614 (1), 628, 629, 649, 830 390 345 667, 668 A4 612, 615617 (1), 630, 631, 634 (1), 900 409 406 650, 652 (1), 653 (1), 655 (1), 669 A4 613, 632, 635637 (1), 651, 654 (1), 1070 409 406 670, 672 (1), 673 (1), 675 (1) A4 633, 671, 674 (1) 1100 409 474 (1) The dimension is given for 1 component. Catalog numbers VW3 A4 614616, 634636, 652654 and 672674 consist of 2 components and catalog numbers VW3 A4 617, 637, 655 and 675 consist of 3 components; all components must be taken into account to determine the overall dimensions.

Presentation: page 75

Characteristics: page 75

Catalog numbers: pages 76 and 77

Wiring diagrams: page 124

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

107

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Additional EMC input filters

Additional EMC input filters


VW3 A4 401404 VW3 A4 405, 409

H1 G a
H 275 309 355 365 479.5 479.5 H1 460 460 4.5 4.5 5.5 5.5 6.6 6.6 H 502.5 631 725 J 40 40 80 6.6 6.6 9

G a

VW3 A4 401 A4 402 A4 403 A4 404 A4 405 A4 409 VW3 A4 406408

a 130 155 175 210 230 230

b 290 324 370 380 498.5 498.5

c 40 50 60 60 62 62

G 105 130 150 190 190 190

J c
VW3 A4 406 A4 407 A4 408

G a
a 240 240 320 b 522 650 750 c 79 79 119 G 200 200 280

Mounting the filter under the drive Front view

Mounting the filter next to the drive Front view

Presentation: page 78

Characteristics: page 79

Catalog numbers: pages 80 and 81

Wiring diagrams: page 124

Functions: pages 144 to 175

108

Global Catalog. Refer to Statement of Scope on page 2.

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Additional EMC input filters

Additional EMC input filters (continued)


VW3 A4 410413

6x12

10

G a1 a

VW3 A4 410 A4 411 A4 412 A4 413

a 800 800 900 1000

a1 302 302 352 401

b 261 261 281 301

b1 219 219 239 259

c 139 139 174 164

G 120 120 145 170

H 235 235 255 275

IP 30 protection kits for filters VW3 A4 410413

b1

b1

170

35 90 = a1 a =

35 90

VW3 A9 601 A9 602

a 1200 1400

a1 800 1000

b 310 350

b1 270 310

Presentation: page 78

Characteristics: page 79

Catalog numbers: pages 80 and 81

Wiring diagrams: page 124

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

109

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Motor chokes

Motor chokes (1)


VW3 A5 101, 102 Mounting recommendations (2)

u 100

u 100

u 100

u 100

u 100

4x H c G a

VW3 A5 101 A5 102

a 190 200

b 210 235

c 90 130

G 170 170

H 45 48

8 x 12 8 x 12

VW3 A5 103 (3) Mounting recommendations (2)

9
226 u 100

4x8x13 180 234

79 101 126
VW3 A5 104, 105 (4)

u 100

u 100

4x H c u 20 G a

VW3 a b c G H A5 104 170 250 100 150 75 9 A5 105 210 250 110 175 75 9 x 13 (1) It is absolutely essential that the motor chokes are mounted on a metal support (grille, frame, etc.) (2) Because of the magnetic field, it is very important to follow the mounting recommendations provided. (3) Because of heat dissipation, this choke must be mounted vertically. (4) Catalog numbers VW3 A5 104 and 105 consist of 3 components.

Presentation: pages 82 and 83

Characteristics: page 83

Catalog numbers: pages 84 and 85

Wiring diagrams: page 124

Functions: pages 144 to 175

110

Global Catalog. Refer to Statement of Scope on page 2.

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Motor chokes

Motor chokes (continued) (1)


VW3 A5 106108 (2)

4x H c u 20 G a

VW3 A5 106 (1) A5 107 (1) A5 108 (1)

a 245 315 370

b 250 250 250

c 200 210 230

G 225 275 325

H 175 175 200

9 9 9

IP 20 protection kits for chokes VW3 A5 104108

H 4x 331 200 G a
VW3 a b G H A9 612 800 600 530 554 10 x 15 A9 613 1200 800 800 757 10 x 15 (1) It is absolutely essential that the motor chokes are mounted on a metal support (grille, frame, etc.) (2) Catalog numbers VW3 A5 106108 consist of 3 components. Presentation: pages 82 and 83 Characteristics: page 83 Catalog numbers: pages 84 and 85 Wiring diagrams: page 124

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

111

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Sinusoidal filters

Sinusoidal filters (1)


VW3 A5 201206 Mounting recommendations

u 300

u 200 u 300 u 300

u 200 u 200

4x

G a

VW3 A5 201 A5 202 A5 203 A5 204 A5 205 A5 206 VW3 A5 207

a 120 120 150 210 250 300

b 335 375 470 650 780 930

c 160 190 240 280 360 415

G 100 100 120 160 200 220

H 280 320 380 530 650 780

6.6 6.6 6.6 8.6 8.6 11 Mounting recommendations

500

4x11x15 194 290 370 420

u 200

u 200

u 200

u 200

u 200

(1) Sinusoidal filters emit considerable heat and must not be placed underneath the drive.

Presentation: pages 82 and 86

Characteristics: page 86

Catalog numbers: page 87

Wiring diagrams: page 124

Functions: pages 144 to 175

112

Global Catalog. Refer to Statement of Scope on page 2.

Dimensions (continued)

Variable speed drives for asynchronous motors


Altivar 71
Sinusoidal filters

Sinusoidal filters (1)


VW3 A5 208211 Mounting recommendations

1 1

4x H c G a

u 200

u 200

u 200

u 200

u 200

VW3 a b c G H 1 A5 208 420 500 345 370 231 11 x 15 11 A5 209 480 600 340 430 238 13 x 18 11 A5 210 480 710 370 430 258 13 x 18 14 A5 211 620 930 500 525 352 13 x 22 4 x 11 (1) Sinusoidal filters emit considerable heat and must not be placed underneath the drive.

Presentation: pages 82 and 86

Characteristics: page 86

Catalog numbers: page 87

Wiring diagrams: page 124

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

113

Wiring diagrams

Variable speed drives for asynchronous motors


Altivar 71
Safety requirements

Power Removal safety function


The Altivar 71 drive integrates the Power Removal safety function which prohibits unintended equipment operation. The motor no longer produces torque. This safety function: b complies with standard for safety of machinary EN 954-1, category 3 b complies with standard for functional safety IEC/EN 61508, SIL2 capability (safety control-signalling applied to processes and systems) The SIL (Safety Integrity Level) capability depends on the connection diagram for the drive and for the safety function. Failure to observe the setup recommendations could inhibit the SIL capability of the Power Removal safety function. b complies with definition of the draft product standard IEC/EN 61800-5-2 for both stop functions: v Safe Torque Off (STO) v Safe Stop 1 (SS1) The Power Removal safety function has a redundant electronic architecture (1) which is monitored continuously by a diagnostics function. This SIL2 and category 3 level of safety function is certified as conforming to these standards by the INERIS certification body under a program of voluntary certification.

Categories relating to safety according to EN 954-1


Categories Basic safety principle B Control system requirements Selection of components Control in accordance with that conform to relevant good engineering practice. standards. Selection of components Use of tried and tested components and proven and basic safety safety principles. principles. Behaviour in the event of a fault Possible loss of safety function.

Possible loss of safety function, but with less probability of this than with B Selection of components Cyclic testing. The test Fault detected at each and basic safety intervals must be suited to the test. principles. machine and its applications. Structure of the safety A single fault must not cause Safety function ensured, except in the circuits. loss of the safety function. event of an This single fault must be accumulation of faults. detected if reasonably practicable. Structure of the safety A single fault must not cause Safety function always ensured. circuits. loss of the safety function. This fault must be detected at or before the next demand on the safety function. An accumulation of faults must not cause loss of the safety function.

The machinary manufacturer is responsible for selecting the safety category. The category depends of the level of risk factors given in standard EN 954-1.

Safety Integrity Levels (SIL) according to standard IEC/EN 61508


SIL1 according to standard IEC/EN 61508 is comparable with category 1 according to EN 954-1 (SIL1: means probability of undetected dangerous failure per hour between 10-5 and 10-6). SIL2 according to standard IEC/EN 61508 is comparable with category 3 according to EN 954-1 (SIL1: means probability of undetected dangerous failure per hour between 10-6 and 10-7).
(1) Redundant: consists of mitigating the effects of failure of one component by means of the correct operation of another, assuming that faults do not occur simultaneously on both.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Functions: pages 144 to 175

114

Global Catalog. Refer to Statement of Scope on page 2.

Wiring diagrams (continued)

Variable speed drives for asynchronous motors


Altivar 71
Safety requirements

Power Removal safety function considerations


The Power Removal safety function cannot be considered as a means of electrical disconnection of the motor (no electrical isolation); if necessary, a Vario switch disconnector must be used. The Power Removal safety function is not designed to overcome any malfunction in the drive process control or application functions. The output signals available on the drive must not be considered as safety related signals (e.g. Power Removal active); these are Preventa-type safety module outputs which must be integrated into a safety related control/command. The wiring diagrams on the following pages take into account conformity with standard IEC/EN 60204-1 which defines three categories of stops: b Category 0: stopping by immediate removal of the power from the machine actuators (i.e. an uncontrolled stop). b Category 1: a controlled stop with power available to the machine actuators to achieve the stop and then removal of power when the stop is achieved. b Category 2: a controlled stop with power left available to the machine actuators.

Connection diagrams and applications


Conformity with category 1 of standard EN 954-1 and level SIL1 according to standard IEC/EN 61508 Use of the connection diagrams on pages 116 and 117 which use a line contactor or a Vario switch disconnector between the drive and the motor. In this case, the Power Removal safety function is not used and the motor stops in accordance with category 0 of standard IEC/EN 60204-1. Conformity with category 3 of standard EN 954-1 and level SIL2 according to standard IEC/EN 61508 The connection diagrams use the Power Removal safety function of the Altivar 71 drive combined with a Preventa safety module which monitors the Emergency stop circuits. Machines with short freewheel stopping times (low inertia or high resistive torque, see page 118). When the activation command is given on the PWR input with the controlled motor, the motor power supply is immediately switched off and the motor stops according to category 0 of standard IEC/EN 60204-1. Restarting is not permitted even when the activation command is given after the motor has come to a complete stop (STO). This safe stop is maintained while the PWR input remains activated. This diagram must also be used for hoisting applications. On a Power Removal command, the drive requires the brake to be engaged, but a Preventa safety module contact must be inserted in series in the brake control circuit to engage it safely when a request is made to activate the Power Removal safety function. Machines with long freewheel stopping times (high inertia or low resistive torque, see page 119). When the activation command is given, deceleration of the motor controlled by the drive is first requested, then, following a time delay controlled by a Preventa-type safety relay which corresponds to the deceleration time, the Power Removal safety function is activated by the PWR input. The motor stops according to category 1 of standard IEC/EN 60204-1 (SS1). Periodic test The Power Removal safety input must be activated at least once a year for preventive maintenance purposes. The drive must be switched off before preventive maintenance takes place, and then powered up again. If during testing the power supply to the motor is not switched off, safety integrity is no longer assured for the Power Removal safety function. The drive must therefore be replaced to ensure the operational safety of the machine or of the process system.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

115

Wiring diagrams (continued)

Variable speed drives for asynchronous motors


Altivar 71

Wiring diagrams conforming to standards EN 954-1 category 1, IEC/EN 61508 SIL1 capability, in stopping category 0 according to IEC/EN 60204-1
ATV 71ppppM3, ATV 71ppppM3X, ATV 71ppppN4
3-phase power supply with upstream breaking via contactor
1 3 5 Q1

ATV 71H075M3HU75M3
Power section for single phase power supply
1 3 Q1 5 6
To 1/Q2 To 3/Q2

1 Q2 2 3 4 5 Q2 6

T1

S2 1 Q3 2

S1

A1

KM1 A2

2 1 KM1 2

KM1 2 4 6

R1A

R1C

KM1 13 14

(1) (2) (2) (2)


R/L1 S/L2 R1A T/L3 A1

(4) (3)
R1C

(1)

+ 24

ATV 71Hppppp
PA/+
W/T3 AI1+ COM

PWR

R/L1

S/L2 W1 W/T3 V/T2

R1B

LI1

LI2

LI3

LI4

LI5

R2C

R2A

LI6

A1

COM

+ 10

PC/

U/T1

AI1

W1

U1

U1

V1

U/T1

V/T2

AO1

AI2

PO

L1

(5)
M 3
Reference potentiometer

(6)
X-Y mA or 010 V

Note: All terminals are located at the bottom of the drive. Fit interference suppressors to all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. Components for use with the Altivar (for a complete list of Catalog numbers, see our Motor starter solutions. Power control and protection components specialist catalogue). Catalog number Description A1 ATV 71 drive, see pages 20 and 21 KM1 Contactor, see motor starters pages 130 to 133 L1 DC choke, see page 71 Q1 Circuit-breaker, see motor starters pages 130 to 133 Q2 GV2 L rated at twice the nominal primary current of T1 Q3 GB2 CB05 S1, S2 XB4 B or XB5 A pushbuttons T1 100 VA transformer 220 V secondary (1) Line choke (single phase or 3-phase), see page 74. (2) For ATV 71HC40N4 drives combined with a 400 kW motor and ATV 71HC50N4, see page 120. (3) Fault relay contacts. Used for remote signalling of the drive status. (4) Connection of the common for the logic inputs depends on the positioning of the SW1 switch: see Wiring diagrams on page 120. (5) DC choke as an option for ATV 71HpppM3, ATV 71HD11M3XHD45M3X, ATV 71H075N4HD75N4. Connected in place of the strap between the PO and PA/+ terminals. For ATV 71HD55M3X, HD75M3X, ATV 71HD90N4HC50N4 drives, the choke is supplied with the drive; the customer is responsible for connecting it. (6) Software-configurable current (020 mA) or voltage (010 V) analog input.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

V1 M 3

A1

Functions: pages 144 to 175

116

Global Catalog. Refer to Statement of Scope on page 2.

Wiring diagrams (continued)

Variable speed drives for asynchronous motors


Altivar 71

Wiring diagrams conforming to standards EN 954-1 category 1, IEC/EN 61508 SIL1 capability, in stopping category 0 according to IEC/EN 60204-1 (continued)
ATV 71ppppM3, ATV 71ppppM3X, ATV 71ppppN4
3-phase power supply with downstream breaking via switch disconnector
1 3 5

ATV 71H075M3HU75M3
Power section for single phase power supply
1 3 5 W1 6/T3 5/L3 W/T3 6

Q1

Q1

(1) (2) (2) (2)


R/L1 S/L2 R1A T/L3

(4) (3)
R1C R1B LI1 LI2 LI3 LI4 LI5 LI6

(1)

+ 24

R2C

R2A

R/L1 U/T1 1/L1 U1 2/T1 V1 4/T2 3/L2

ATV 71Hppppp
PA/+
W/T3 AI1+ COM

COM

+ 10

PC/

U/T1

AI1

V/T2

PWR

1/L1

3/L2

5/L3

L1 Q2
U1 2/T1 V1 4/T2 W1 6/T3

(5)
Reference potentiometer

(6)
X-Y mA or 010 V Q2

M 3

M 3

Note: All terminals are located at the bottom of the drive. Fit interference suppressors to all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. Components for use with the Altivar (for a complete list of catalog numbers, see our Motor starter solutions. Power control and protection components specialist catalogue). Catalog number Description A1 ATV 71 drive, see pages 20 and 21 L1 DC choke, see page 71 Q1 Circuit-breaker, see motor starters pages 130 to 133 Q2 Switch disconnector (Vario) (1) Line choke (single phase or 3-phase), see page 74. (2) For ATV 71HC40N4 drives combined with a 400 kW motor and ATV 71HC50N4, see page 120. (3) Fault relay contacts. Used for remote signalling of the drive status. (4) Connection of the common for the logic inputs depends on the positioning of the SW1 switch: see wiring diagrams on page 120. (5) DC choke as an option for ATV 71HpppM3, ATV 71HD11M3XHD45M3X, ATV 71H075N4HD75N4. Connected in place of the strap between the PO and PA/+ terminals. For ATV 71HD55M3X, HD75M3X, ATV 71HD90N4HC50N4 drives, the choke is supplied with the drive; the customer is responsible for connecting it. (6) Software-configurable current (020 mA) or voltage (010 V) analog input.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

V/T2

AO1

AI2

PO

S/L2

A1

A1

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

117

Wiring diagrams (continued)

Variable speed drives for asynchronous motors


Altivar 71

Wiring diagrams conforming to standards EN 954-1 category 3, IEC/EN 61508 SIL2 capability, in stopping category 0 according to IEC/EN 60204-1
ATV 71HpppM3, ATV 71HpppM3X, ATV 71HpppN4
3-phase power supply, low inertia machine, vertical movement
L1 (+) F1

ATV 71H075M3HU75M3
Power section for single phase power supply
1 3

Q1

(1)
N () S1

(2)
ESC

Q1

(3)
2 4 6

(2)
A2 A1 Y1 Y2
Logic

13 K1 K2

23

33

Y43 2 4 6 W1 W/T3

XPS AC
T

+
K1 PE

(4)
48 V, 115 V, 230 V A2 K2 14 24 34 Y44

(4)

(5) (8) (6) (6) (6)


R/L1 S/L2 R1A T/L3

(9)
PWR

(7)
R1C R1B LI1 LI2 LI3 LI4 LI5 LI6

+ 24

R2C

R2A

R/L1

PA/+

ATV 71Hppppp
AI1+ COM

W/T3

COM

+ 10

PC/

U/T1

AI1

V/T2

AO1

U/T1

AI2

W1

U1

V1

U1

(10)
M 3
Reference potentiometer

(11)
X-Y mA or 010 V

Note: All terminals are located at the bottom of the drive. Fit interference suppressors to all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. Components for use with the Altivar (for a complete list of catalog numbers, see our Motor starter solutions. Power control and protection components and Preventa safety solutions specialist catalogues). Catalog number Description A1 ATV 71 drive, see pages 20 and 21 A2 Preventa XPS AC safety module for monitoring emergency stops and switches. One safety module can manage the Power Removal function for several drives on the same machine. F1 Fuse L1 DC choke, see page 71 Q1 Circuit-breaker, see motor starters pages 130 to 133 S1 Emergency stop button with 2 contacts S2 XB4 B or XB5 A pushbutton (1) Power supply: c or a 24 V, a 48 V, a 115 V, a 230 V. (2) S2: resets XPS AC module on power-up or after an emergency stop. ESC can be used to set external starting conditions. (3) Requests freewheel stopping of the movement and activates the Power Removal safety function. (4) Line choke (single phase or 3-phase), see page 74. (5) The logic output can be used to signal that the machine is in a safe stop state. (6) For ATV 71HC40N4 drives combined with a 400 kW motor and ATV 71HC50N4, see page 120. (7) Fault relay contacts. Used for remote signalling of the drive status. (8) Connection of the common for the logic inputs depends on the positioning of the SW1 switch: see wiring diagrams on page 120. (9) Standardized coaxial cable, type RG174/U according to MIL-C17 or KX3B according to NF C 93-550, external diameter 2.54 mm, maximum length 2 m. The cable shielding must be earthed. (10)Optional DC choke for ATV 71HppppM3, ATV 71HD11M3XHD45M3X, ATV 71H075N4HD75N4. Connected in place of the strap between the PO and PA/+ terminals. For ATV 71HD55M3X, HD75M3X, ATV 71HD90N4HC50N4 drives, the choke is supplied with the drive; the customer is responsible for connecting it. (11)Software-configurable current (020 mA) or voltage (010 V) analog input.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

V1

L1

M 3

118

Global Catalog. Refer to Statement of Scope on page 2.

V/T2

PO

Functions: pages 144 to 175

S/L2

A1

A1

S2

Wiring diagrams (continued)

Variable speed drives for asynchronous motors


Altivar 71

Wiring diagrams conforming to standards EN 954-1 category 3, IEC/EN 61508 capability SIL2, in stopping category 1 according to IEC/EN 60204-1
ATV 71HpppM3, ATV 71HpppM3X, ATV 71HpppN4
3-phase power supply, high inertia machine

ATV 71H075M3HU75M3
Power section for single phase power supply

Q1

(1)

L1 (+)

F1

()

( +) S1(2)

Q1

A2

A1 S21 S11 B1

S12 S22

13

23

33 41 57

67

XPS AT
A2 PE S33 Y1 Y2 Y3 Y4 Y5 N () 14 24 34 42 58 68

030 s

(5)
S2 (4) ESC

(6) (3)

(3)

(4)

(9) (7) (7) (7)


R/L1 S/L2 R1A T/L3
A1

(10)
PWR

(8)
R1C R1B LI1 LI2 LI3 LI4 LI5 LI6

+ 24

R2C

R2A

R/L1

(11)
AI1

ATV 71Hppppp
COM

PA/+

W/T3

AI1+

COM

+ 10

PC/

U/T1

V/T2

AO1

S/L2

A1

W1

U1

V1

(12)
M 3
Reference potentiometer

(13)
X-Y mA or 010 V

M 3

Note: All terminals are located at the bottom of the drive. Fit interference suppressors to all inductive circuits near the drive or connected on the same circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc. Components for use with the Altivar (for a complete list of catalog numbers, see our Motor starter solutions. Power control and protection components and Preventa safety solutions specialist catalogues). Catalog number Description A1 ATV 71 drive, see pages 20 and 21 A2 (6) Preventa XPS AT safety module for monitoring emergency stops and switches. One safety module can manage the Power Removal function for several drives on the same machine, but the time delay must be adjusted on the drive controlling the motor that requires the longest stopping time. F1 Fuse L1 DC choke, see page 71 Q1 Circuit-breaker, see motor starters pages 130 to 133 S1 Emergency stop button with 2 contacts S2 XB4 B or XB5 A pushbutton (1) Power supply: c or a 24 V, a 115 V, a 230 V. (2) Requests controlled stopping of the movement and activates the Power Removal safety function. (3) Line choke (single phase or 3-phase), see page 74. (4) S2: resets XPS AC module on power-up or after an emergency stop. ESC can be used to set external starting conditions. (5) The N/C contact can be used to signal that the machine is in a safe stop state. (6) For stopping times requiring more than 30 seconds in category 1, use a Preventa XPS AV safety module which can provide a maximum time delay of 300 seconds. (7) For ATV 71HC40N4 drives combined with a 400 kW motor and ATV 71HC50N4, see page 120. (8) Fault relay contacts. Used for remote signalling of the drive status. (9) Connection of the common for the logic inputs depends on the positioning of the SW1 switch: see wiring diagrams on page 120. (10)Standardized coaxial cable, type RG174/U according to MIL-C17 or KX3B according to NF C 93-550, external diameter 2.54 mm, maximum length 2 m. The cable shielding must be earthed. (11)Logic inputs LI1 and LI2 must be assigned to the direction of rotation: LI1 in the forward direction and LI2 in the reverse direction. (12)Optional DC choke for ATV 71HppppM3, ATV 71HD11M3XHD45M3X, ATV 71H075N4HD75N4. Connected in place of the strap between the PO and PA/+ terminals. For ATV 71HD55M3X, HD75M3X, ATV 71HD90N4HC50N4 drives, the choke is supplied with the drive; the customer is responsible for connecting it. (13)Software-configurable current (020 mA) or voltage (010 V) analog input.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

W1

U1

V1

L1

W/T3

U/T1

V/T2

AI2

PO

119

Wiring diagrams (continued)

Variable speed drives for asynchronous motors


Altivar 71

Power terminal connections for ATV 71HC40N4 combined with a 400 kW motor and ATV 71HC50N4
To circuit-breaker (1)

(2)

(2)

L1A

L2A

L3A

L1B

L2B

(1) For control section connections, see pages 116 to 119. (2) Line choke, see page 74.

VW3 A7 7pp braking resistors or VW3 A7 8pp hoisting resistors, VW3 A7 1pp braking units
ATV 71HpppM3, HpppM3X, ATV 71H075N4HC16N4
PA/+
A1

L3B

ATV 71HC20N4HC50N4

A1

L1
Braking resistor

PA/+

PC/

PB

PO

TH

Braking resistor

+
Braking unit

PA PB

(1)

A2

Components for use with the Altivar Catalog number A1 A2 L1 Braking resistor

Description ATV 71 drive, see pages 20 and 21 Braking unit, if using a braking resistor or a hoisting resistor, for ATV 71HC20N4HC50N4, see pages 50 and 51 DC choke provided as standard with the drive See pages 52 to 55

(1) Thermal overload relay if there is no temperature controlled switch in the sequence.

Examples of recommended wiring diagrams


Logic inputs The SW1 switch is used to adapt operation of the logic inputs (LI) to the PLC output technology: b Position the switch on Supply (factory setting) if using PLC outputs with PNP transistors b Position the switch on Int Sink or Ext Sink if using PLC outputs with NPN transistors
Internal power supply Switch on Supply position
SW1
Supply

Switch on Int Sink position


SW1 Supply Sink Ext. Int.

Sink Ext. Int.

ATV 71Hppppp

ATV 71Hppppp

+24

+24

0V

LI1

LI2

LI3

LI4

LI5

LI6

SW2 PTC LI

SW2 PTC LI

External power supply Switch on Supply position


SW1
Supply

Switch on Ext Sink position


SW1
Supply

+24

+24

Sink Ext. Int.

ATV 71Hppppp
0V LI1 LI2 LI3 LI4 LI5 LI6

Sink Ext. Int.

ATV 71Hppppp
0V LI1 LI2 LI3 LI4 LI5 LI6

SW2 PTC LI

SW2

+ 24 V
0V
24 V c supply

PTC LI

+ 24 V
0V
24 V c supply

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Functions: pages 144 to 175

120

Global Catalog. Refer to Statement of Scope on page 2.

0V

LI1

LI2

LI3

LI4

LI5

LI6

Wiring diagrams (continued)

Variable speed drives for asynchronous motors


Altivar 71

Examples of recommended wiring diagrams (continued)


Input for PTC probes The SW2 switch is used to operate the LI6 input: b As a logic input by setting the SW2 switch to LI (factory setting) b Or for protecting the motor via PTC probes by setting the SW2 switch to PTC
SW2 PTC LI A1

ATV 71Hppppp
0V LI6

Motor

2-wire control and jog operation (JOG)


ATV 71H

3-wire control and jog operation (JOG)


ATV 71H

+ 24

Stop Forward Forward Reverse JOG

Reverse

JOG forward JOG reverse

Unipolar speed reference

Bipolar speed reference


Requires a VW3 A3 201 or VW3 A3 202 I/O extension card

ATV 71H
AI1 COM AI1+ AI1+

ATV 71Hppppp
AI1 COM

VW3 A3 20p 10

+10

Reference potentiometer

Speed reference using axis control


ATV 71H
AI1 COM AI1+

Separate control power supply


The separate control card can be powered by an external 24 V c supply

+10

Reference potentiometer

ATV 71H
P 24

0V

Reference 10 V

0V

Axis control

+ 24 V
24 V c supply

Analog input configured for voltage


External 010 V External + 10 V

Analog input configured for current


0-20 mA, 4-20 mA, X-Y mA

COM

COM

AI2

010 V

+ 10 V

Speed reference potentiometer 2.2 to 10 k

Supply 0-20 mA 4-20 mA X-Y mA

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

COM

ATV 71H

ATV 71H
AI2

ATV 71H
AI2

0V

+ 24
Functions: pages 144 to 175

LI1

LI2

LI3

LI

LI

LI

Global Catalog. Refer to Statement of Scope on page 2.

LI4

121

Wiring diagrams (continued)

Variable speed drives for asynchronous motors


Altivar 71

VW3 A3 201 and VW3 A3 202 I/O extension cards


Logic I/O The SW4 switch is used to adapt operation of the logic inputs (LI) to the PLC output technology: b Position the switch on Supply (factory setting) if using PLC outputs with PNP transistors b Position the switch on Int Sink or Ext Sink if using PLC outputs with NPN transistors
Internal power supply Switch on Supply position
RpC RpA RpB

Switch on Int Sink position


RpC RpA

VW3 A3 20p

RpB

VW3 A3 20p

SW4

SW4
THp THp

CLO

+24

CLO

LOp

LOp

THp

+24

LOp

Motor

LOp

THp

0V

0V

LIp

LIp

Supply

Sink Ext. Int.

Supply

Sink Ext. Int.

Motor

External power supply Switch on Supply position


RpC RpA RpB

Switch on Ext Sink position


RpC RpA

VW3 A3 20p

RpB

VW3 A3 20p

SW4

SW4 THp + THp THp Sink Ext. Int.

CLO

Supply

Supply

+ 24 V
0V
24 V c supply

Motor

CLO

THp

+24

LOp

LOp

+24

LOp

LOp

Sink Ext. Int.

0V

0V

LIp

LIp

+ 24 V
0V
24 V c supply

Motor

Analog I/O (only on VW3 A3 202 extended I/O card)


VW3 A3 202
AO2 (1) AO3 (1) AI3 + AI3 COM COM AI4 0V
R (3)

(2)
Supply 0-20 mA 4-20 mA X-Y mA

X-Y mA or 010 V

(1)

(1) Software-configurable current (0-20 mA) or voltage (010 V) analog input. (2) Software-configurable current (0-20 mA) or voltage ( 10 V or 010 V) analog outputs, independent selection possible for each output via switch). (3) R: add a resistor if the input voltage of the pulse train is greater than 5 V. Recommended values: Input voltage Resistance V 12 510 15 910 24 1300

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

RP

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Functions: pages 144 to 175

122

Global Catalog. Refer to Statement of Scope on page 2.

Wiring diagrams (continued)

Variable speed drives for asynchronous motors


Altivar 71

VW3 A3 401 to VW3 A3 407 encoder interface cards


Closed loop control
Wiring the encoder
VW3 A3 40p

+ Vs + Vs

Encoder

VW3 A3 501 programmable Controller Inside card


Card powered by the drive (1)
ATV 71Hppppp VW3 A3 501

SW1

LO5p

LO5p

Supply

+ 24 V

0-20 mA 0-20 mA

Card powered by external power supply


VW3 A3 501

AO51

AO52

LO5p

LO5p

COM

COM

COM

24 V

AI51

AI52

LI5p

Sink Ext. Int.

0 Vs

0 Vs

+ 24 V
0V
24 V c supply

0-20 mA 0-20 mA

0-20 mA 0-20 mA

(1) Only if the power consumption is less than 200 mA; otherwise use an external power supply.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

COM

24 V

AI51

AI52

LI5p

Dimensions: pages 92 to 113

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

123

Wiring diagrams (continued)

Variable speed drives for asynchronous motors


Altivar 71

VW3 A4 6pp passive filters

X2.1 X1.1

X2.2 X1.2

X2.3 X1.3 L3

VW3 A4 6pp

L1

L2

ATV 71HpppN4

VW3 A4 4pp additional EMC input filters


3-phase power supply, 3-phase filter Single phase power supply, 3-phase filter

(1)

L1

L2

L3

L1

L2

L3 L3 W WT/3 W
VW3 A5 2pp

L'1

L'2

L'3

L'1

L'2

L1

L2

L3

L1

L2

L'3

VW3 A3 4pp

VW3 A3 4pp

ATV 71Hppppp

ATV 71Hppppp

VW3 A5 ppp output filters


VW3 A5 1pp motor chokes VW3 A5 2pp sinusoidal filters
ATV 71Hppppp

ATV 71Hppppp

U UT/1 U
VW3 A5 1pp

UT/1

VT/2

W WT/3

PE

PE

VT/2

PE

PE

W1

M 3

M 3

(1) Line choke compulsory for ATV 71HU40M3XHU75M3X.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

W1

U1

U1

V1

V1

Dimensions: pages 92 to 113

Functions: pages 144 to 175

124

Global Catalog. Refer to Statement of Scope on page 2.

Wiring diagrams (continued)

Variable speed drives for asynchronous motors


Altivar 71

Network braking unit


L1 L2 L3 N PE

Q1

L1 230 V N
2 4 6

F1
1 3 4 5 6

KM1
2

(1)

F2 F3 F4

(2)
N PE L1 L2 L3

A2

(3) (3) (3)


R1C R1A R1B R/L1 S/L2 T/L3 R2C R2A

A1

PA/+ PC/

Relay

ATV 71Hppppp
W/T3 U/T1

+ 24

V/T2

LI1

X2

M 3

Components for use with the Altivar (for a complete list of catalog numbers, see our Motor starter solutions. Power control and protection components specialist catalogue). Catalog number Description A1 ATV 71 drive, see pages 20 and 21 A2 Network braking unit (see page 64) F1 2 A fuse, a 230 V F2F4 For fuses, see catalog number tables on pages 65 and 66. Q1 Circuit-breaker DDR 300 mA. Protects against earth leakage faults. Rating: see motor starters on pages 130 to 133 (1) Additional EMC input filter if necessary, see page 80. (2) Line choke recommended, see page 74. (3) For ATV 71HC40N4 drives combined with a 400 kW motor and ATV 71HC50N4, see page 120.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

W1

U1

V1

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

L1

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

125

Wiring diagrams (continued)

Variable speed drives for asynchronous motors


Altivar 71

Drives combined with a braking unit and wired onto the same DC bus
ATV 71HC20N4HC50N4
3a 3a

L1

L1

L2 V

L2

L3

ATV 71 PA/+ HC20N4 HC50N4 PO PC/

ATV 71 PA/+ HC20N4 HC50N4 PO PC/


U W

TH

M
Braking resistor

L3

TH

Braking resistor

PA PB

+
(1)

PA PB

(1)

Braking unit

Braking unit

(1) Thermal overload relay if there is no temperature controlled switch in the sequence.

Drive powered by external DC power supply


ATV 71HD18M3XHD45M3X, ATV 71HD22N4HD75N4

DC power supply (1)

F1

F2

(2)
A1 R1 - KM1 A2

(2)
R2 - KM2 A2 R2C PA/+ PC/ M 3 A1

PA/+

PC/

W/T3

W1

M 3

For drives A1, A2

DC power supply

A ATV 71HD18M3X 135 LC1 D32pp ATV 71HD22M3X 157 LC1 D40pp ATV 71HD30M3X 200 LC1 D65pp ATV 71HD37M3X 237 LC1 D80pp ATV 71HD45M3X 279 LC1 D80pp ATV 71HD22N4 93 LC1 D25pp ATV 71HD30N4 118 LC1 D32pp ATV 71HD37N4 139 LC1 D38pp ATV 71HD45N4 163 LC1 D40pp ATV 71HD55N4 189 LC1 D50pp ATV 71HD75N4 244 LC1 D80pp (1) DC power supply not included. (2) Fast-acting fuses, see page 128. The function of the fuses is to protect the DC bus wiring in the event of a drive short-circuit. (3) See our Motor starter solutions. Power control and protection components specialist catalogue. Note: ATV 71HpppM3, ATV 71HD11M3X, H015M3X and ATV 71H075N4HD18N4 drives have an integrated pre-charge circuit. This is used to connect the DC power supply directly to the drive without the need for an external pre-charge circuit.

Braking resistors R1, R2 Value Catalog number 5 VW3 A7 707 5 VW3 A7 707 5 VW3 A7 707 5 VW3 A7 707 5 VW3 A7 707 5 VW3 A7 707 5 VW3 A7 707 5 VW3 A7 707 5 VW3 A7 707 5 VW3 A7 707 5 VW3 A7 707

W1

U1

U1

V1

V1

W/T3

U/T1

U/T1

V/T2

V/T2

R2C

R2A

R2A

P0

P0

A1

A2

Contactors (3) KM1, KM2

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Functions: pages 144 to 175

126

Global Catalog. Refer to Statement of Scope on page 2.

Wiring diagrams (continued)

Variable speed drives for asynchronous motors


Altivar 71

Connection diagrams for several drives in parallel on the DC bus


Drives with different ratings

Q1

KM1 F2 IL F3

L2

L1

L3

PA/+

PA/+

PC/

ATV 71Hppppp

F1

ATV 71Hppppp

ATV 71Hppppp

M1

M2

M3

Catalog number A1 A2, A3 F1 F2, F3

Description ATV 71 drive, see pages 20 and 21. Drive power = motor power ratings M1 + M2 + M3 + ATV 71 drives powered by the DC bus. They must be protected using fast-acting fuses. Contactors on the DC circuit are ineffective as the switching action may cause the fuses to blow owing to the high load current. Fast-acting fuses, see page 128. Drive A1 powered by the AC supply with an output bus. The function of the fuse is to protect the internal diode bridge in the event of a short-circuit on the external DC bus. Fast-acting fuses, see page 128. Drives A2 and A3 are powered by their DC bus and are not connected to the AC input. The function of the fuses is to protect the DC bus wiring in the event of a drive short-circuit.

Drives with equivalent ratings

KM1

Q1

Q2

Q3

F1

F2

PC/

A1

A2

A3

F3

L2

L3

L2

L3

L2

L1

L1

PO

PO

L1

L3

A1

L1 (1) ATV 71Hppppp

A2

L2 (1) ATV 71Hppppp

A3

L3 (1) PO ATV 71Hppppp

PA/+
PC/

PA/+
PC/

PA/+
PC/

M1

M2

M3

Catalog number A1, A2, A3 F1, F2, F3 KM1 L1, L2, L3 Q1, Q2, Q3

Description ATV 71 drive, see pages 20 and 21. The power difference between the drives connected in parallel must not exceed any rating. Fast-acting fuses, see page 128. Drives A1, A2 and A3 powered by the AC supply with an output bus. The function of the fuse is to protect the internal diode bridge in the event of a short-circuit on the external DC bus. When using a common line contactor, all the Altivar 71 drive load circuits operate in parallel and cannot therefore be overloaded. DC chokes, see page 71.

Circuit-breakers on the line supply side to protect drives against overloads. Use trip contacts on the external fault logic input or the line contactor. The line contactor must only be activated if all three circuit-breakers are closed, as otherwise there is a risk of damage to the drives. (1) DC chokes compulsory except for ATV 71HD11M3XHD45M3X and ATV 71HD18N4HD75N4 (these drives include a DC choke as standard).

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

127

Combinations

Variable speed drives for asynchronous motors


Altivar 71

Size of DC bus fuses (F1, F2, F3) depending on the drive rating
Fast-acting fuses (1) A ATV 71H037M3HU15M3 25 ATV 71HU22M3HU40M3 50 ATV 71HU55M3, HU75M3 100 ATV 71HD11M3XHD18M3X 160 ATV 71HD22M3X, HD30M3X 250 ATV 71HD37M3X, HD45M3X 350 ATV 71HD55M3X 500 ATV 71HD75M3X 630 ATV 71H075N4HU22N4 25 ATV 71HU30N4, HU40N4 50 ATV 71HU55N4HD11N4 80 ATV 71HD15N4HD22N4 100 ATV 71HD30N4, HD37N4 160 ATV 71HD45N4 200 ATV 71HD55N4 250 ATV 71HD75N4 350 ATV 71HD90N4 315 ATV 71HC11N4, HC13N4 400 ATV 71HC16N4 500 ATV 71HC20N4 630 ATV 71HC25N4, HC28N4 800 ATV 71HC31N4 1000 ATV 71HC40N4, HC50N4 1250 (1) Nominal voltage of fast-acting fuse: Line voltage Nominal voltage of fast-acting fuse aV V 230 690 400 690 440 800 460 800 480 800 For drives

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Functions: pages 144 to 175

128

Global Catalog. Refer to Statement of Scope on page 2.

Recommendations for setup

Variable speed drives for asynchronous motors


Altivar 71
Electromagnetic compatibility

Connections for ensuring conformity to EMC standards


Principle b Grounds between drive, motor and cable shielding must have high frequency equipotentiality. b Use shielded cables with shielding connected to ground over 360 at both ends for the motor cable, the braking resistor cable and the control-signalling cables. Conduit or metal ducting can be used for part of the shielding length provided that there is no break in the continuity of the earth connections. b Ensure maximum separation between the power supply cable (line supply) and the motor cable. Installation diagram for ATV 71Hppppp drives

9 9 1 3 87 6 4

9 5

ATV 71HpppM3, ATV 71HD11M3X, HD15M3X, ATV 71H075N4HD18N4

1 2 3 4 5

6 7

9 1

9 5
9

Steel plate (1), to be fitted on the drive (machine ground). Altivar 71 drive. Unshielded power supply wires or cable. Unshielded wires for the output of the fault relay contacts. Fix and earth the shielding of cables 6, 7 and 8 as close as possible to the drive: - strip the shielding. - fix the cable to the plate 1 by attaching the clamp to the stripped part of the shielding. The shielding must be clamped tightly enough to the metal plate to ensure good contact. Shielded cable for connecting the motor. Shielded cable for connecting the control/signalling wiring. For applications requiring several conductors, use cables with a small crosssection (0.5 mm2). Shielded cable for connecting the braking resistor. 6, 7, 8 the shielding must be connected to ground at both ends. The shielding must be continuous and intermediate terminals must be placed in EMC shielded metal boxes. Ground screw.

6 7 4

ATV 71HD18M3XHD45M3X, ATV 71HD22N4HD75N4

Note: The HF equipotential ground connection between the drive, motor and cable shielding does not remove the need to connect the PE protective conductors (green-yellow) to the appropriate terminals on each unit. If using an additional EMC input filter, it should be mounted beneath the drive and connected directly to the line supply via an unshielded cable. Link 3 on the drive is via the filter output cable. (1) Plate supplied for ATV 71HpppM3, ATV 71HD11M3X, HD45M3X and ATV 71H075N4HD75N4 drives. For ATV 71HD55M3X, HD75M3X and ATV 71HD90N4HC50N4 drives, the plate is supplied with the NEMA type 1 conformity kit or the IP 21 or IP 31 conformity kit, to be ordered separately, see pages 24 and 25.

ATV 71HD55M3X, HD75M3X, ATV 71HD90N4HC50N4

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Functions: pages 144 to 175

Global Catalog. Refer to Statement of Scope on page 2.

129

Combinations for customer assembly

Variable speed drives for asynchronous motors


Altivar 71
Motor starters: supply voltage 200240 V

533367

Applications
Circuit-breaker/contactor/drive combinations can be used to ensure continuous service of the installation with optimum safety. The type of circuit-breaker/contactor coordination selected can reduce maintenance costs in the event of a motor short-circuit by minimizing the time required to make the necessary repairs and the cost of replacement equipment. The suggested combinations provide type 1 or type 2 coordination depending on the drive rating. Type 2 coordination: A motor short-circuit will not damage the device or affect its settings. The motor starter should be able to operate once the electrical fault has been removed. The electrical isolation provided by the circuit-breaker will not be affected by the short-circuit. Welding of the contactor contacts is permissible if they can be separated easily. Type 1 coordination: The electrical isolation provided by the circuit-breaker will not be affected by the incident and no other elements apart from the contactor are damaged as a result of the motor short-circuit. The drive controls the motor, provides protection against short-circuits between the drive and the motor and protects the motor cable against overloads. The overload protection is provided by the drive's motor thermal protection. If this protection is removed, external thermal protection should be provided. Before restarting the installation, the cause of the trip must be removed.

533431

103282_18

Single phase supply voltage 200240 V 50/60 Hz


Motor Power (1) kW HP Drive Catalog number Circuit-breaker Catalog number Rating (2) A Im Line contactor Catalog number (3) (4)

Type 2 coordination
0.37 0.5 ATV 71H075M3 GV2 L10 6.3 LC1 D18pp 0.75 1 ATV 71HU15M3 GV2 L14 10 LC1 D18pp 1.5 2 ATV 71HU22M3 GV2 L20 18 LC1 D25pp 2.2 3 ATV 71HU30M3 GV2 L22 25 LC1 D25pp 3 ATV 71HU40M3 (5) GV2 L22 25 LC1 D25pp 4 5 ATV 71HU55M3 (5) NS80HMA50 50 300 LC1 D40pp 5.5 7.5 ATV 71HU75M3 (5) NS80HMA50 50 300 LC1 D50pp (1) Standard power ratings for 4-pole motors 50/60 Hz 230 V. The values expressed in HP comply with the NEC (National Electrical Code). (2) NS80HMA: product sold under the Merlin Gerin brand. Breaking capacity of circuit-breakers according to standard IEC60947-2: Circuit-breaker Icu (kA) for 240 V GV2 L 50 NS80HMA 100 (3) Composition of contactors: LC1 D18 to LC1 D50: 3 poles + 1 N/O auxiliary contact and 1 N/C auxiliary contact. (4) Replace pp with the control circuit voltage reference indicated in the table below. Volts a 24 48 110 220 230 240 LC1 D 50 Hz B5 E5 F5 M5 P5 U5 60 Hz B6 E6 F6 M6 U6 50/60 Hz B7 E7 F7 M7 P7 U7 For other voltages available between 24 V and 660 V, or a DC control circuit, please consult your Regional Sales Office. (5) A line choke must be added (see page 74).

GV2 L20 + LC1 D25pp + ATV 71HU22M3

130

Global Catalog. Refer to Statement of Scope on page 2.

Combinations for customer assembly


(continued)

Variable speed drives for asynchronous motors


Altivar 71
Motor starters: supply voltage 200240 V

046751_25

3-phase supply voltage 200240 V 50/60 Hz


Motor Power (1) Drive Catalog number Circuit-breaker Catalog number (2) Rating Im Line contactor Catalog number (3) (4)

kW

HP

Type 2 coordination
0.37 0.5 ATV 71H037M3 GV2 L08 4 LC1 D09pp 0.75 1 ATV 71H075M3 GV2 L14 10 LC1 D09pp 1.5 2 ATV 71HU15M3 GV2 L14 10 LC1 D18pp 2.2 3 ATV 71HU22M3 GV2 L16 14 LC1 D18pp 3 ATV 71HU30M3 GV2 L20 18 LC1 D25pp 4 5 ATV 71HU40M3 GV2 L22 25 LC1 D25pp 5.5 7.5 ATV 71HU55M3 NS80HMA50 50 300 LC1 D40pp 7.5 10 ATV 71HU75M3 NS80HMA50 50 300 LC1 D50pp 11 15 ATV 71HD11M3X NS80HMA80 80 480 LC1 D65pp 15 20 ATV 71HD15M3X NS100NMA80 80 480 LC1 D65pp 18.5 25 ATV 71HD18M3X NS100NMA100 100 600 LC1 D80pp 22 30 ATV 71HD22M3X NS100NMA100 100 600 LC1 D80pp 30 40 ATV 71HD30M3X NS160NMA150 150 1350 LC1 D115pp 37 50 ATV 71HD37M3X NS160NMA150 150 1350 LC1 D150pp 45 60 ATV 71HD45M3X NS250NMA220 220 1980 LC1 D150pp 55 75 ATV 71HD55M3X NS250NMA220 220 1980 LC1 F225pp 75 100 ATV 71HD75M3X NS400NSTR43ME 320 2880 LC1 F265pp (1) Standard power ratings for 4-pole motors 50/60 Hz 230 V. The values expressed in HP comply with the NEC (National Electrical Code). (2) NS80HMA, NSpppN: products sold under the Merlin Gerin brand. Breaking capacity of circuit-breakers according to standard IEC60947-2: Circuit-breaker Icu (kA) for 240 V GV2 L08L20 100 GV2 L22 50 NS80HMA 100 NSpppNMA 85 (3) Composition of contactors: LC1 D09 to LC1 D150: 3 poles + 1 N/O auxiliary contact and 1 N/C auxiliary contact. LC1 Fppp: 3 poles. To add auxiliary contacts or other accessories, please consult our specialist catalogue Motor-starter solutions. Control and protection components. (4) Replace pp with the control circuit voltage reference indicated in the table below. Volts a 24 48 110 220 230 240 LC1 D 50 Hz B5 E5 F5 M5 P5 U5 60 Hz B6 E6 F6 M6 U6 50/60 Hz B7 E7 F7 M7 P7 U7 LC1 F225 50 Hz (LX1 coil) B5 E5 F5 M5 P5 U5 60 Hz (LX1 coil) E6 F6 M6 U6 40400 Hz (LX9 coil) E7 F7 M7 P7 U7 LC1 F265 40400 Hz (LX1 coil) B7 E7 F7 M7 P7 U7 For other voltages available between 24 V and 660 V, or a DC control circuit, please consult your Regional Sales Office.

533344

103308_22

NS80HMA50 + LC1 D40pp + ATV 71HU55M3

Global Catalog. Refer to Statement of Scope on page 2.

131

Combinations for customer assembly


(continued)

Variable speed drives for asynchronous motors


Altivar 71
Motor starters: supply voltage 380415 V

533345

3-phase supply voltage 380415 V 50/60 Hz


Motor Power (1) kW 0.75 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 220 250 280 315 355 HP 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400 450 500 ATV 71H075N4 ATV 71HU15N4 ATV 71HU22N4 ATV 71HU30N4 ATV 71HU40N4 ATV 71HU55N4 ATV 71HU75N4 ATV 71HD11N4 ATV 71HD15N4 ATV 71HD18N4 ATV 71HD22N4 ATV 71HD30N4 ATV 71HD37N4 ATV 71HD45N4 ATV 71HD55N4 ATV 71HD75N4 ATV 71HD90N4 ATV 71HC11N4 ATV 71HC13N4 ATV 71HC16N4 ATV 71HC20N4 ATV 71HC25N4 ATV 71HC25N4 ATV 71HC28N4 ATV 71HC31N4 ATV 71HC40N4 GV2 L08 GV2 L10 GV2 L14 GV2 L16 GV2 L16 GV2 L22 NS80HMA50 NS80HMA50 NS80HMA50 NS80HMA50 NS80HMA80 NS80HMA80 NS100pMA100 NS160pMA150 NS160pMA150 NS250pMA150 NS250pMA220 NS250pMA220 NS400pSTR43MEF NS400pSTR43MEF NS400pSTR43MEF NS630pSTR43MEF NS630pSTR43MEF NS630pSTR43MEF NS630pSTR43MEF Drive Catalog number Circuit-breaker Catalog number (2) Rating Im A 4 6.3 10 14 14 25 50 50 50 50 80 80 100 150 150 150 220 220 320 320 320 500 500 500 500 A 300 300 300 300 480 480 800 1350 1350 1350 1980 1980 2880 2880 2880 4500 4500 4500 4500 LC1 D18pp LC1 D18pp LC1 D18pp LC1 D18pp LC1 D18pp LC1 D25pp LC1 D40pp LC1 D40pp LC1 D50pp LC1 D50pp LC1 D65pp LC1 D65pp LC1 D80pp LC1 D115pp LC1 D115pp LC1 D150pp LC1 F185pp LC1 F185pp LC1 F265pp LC1 F265pp LC1 F400pp LC1 F400pp LC1 F500pp LC1 F500pp LC1 F500pp Line contactor Catalog number (3) (4)

Type 2 coordination

533368

105517_18

Type 1 coordination
NS800 MicroLogic 800 1600 LC1 F630pp 2 or 5 (LR OFF) 400 600 ATV 71HC40N4 NS800 MicroLogic 800 1600 LC1 F630pp 2 or 5 (LR OFF) 500 800 ATV 71HC50N4 NS1000 MicroLogic 1000 2000 LC1 F800pp 2 or 5 (LR OFF) (1) Standard power ratings for 4-pole motors 50/60 Hz 400 V. The values expressed in HP comply with the NEC (National Electrical Code). (2) NS80HMA, NSpppp, NS800, NS1000: products sold under the Merlin Gerin brand. For catalog numbers to be completed, replace the dot with the letter corresponding to the circuit-breaker performance (N, H, L). Breaking capacity of circuit-breakers according to standard IEC60947-2: Circuit-breaker Icu (kA) for 400 V N H L GV2 L08L14 100 GV2 L16L22 50 NS80HMA 70 NS100pMA, NS160pMA, NS250pMA 36 70 150 NS400p, NS630p, NS800, NS1000 50 70 150 (3) Composition of contactors: LC1 D18 to LC1 D150: 3 poles + 1 N/O auxiliary contact and 1 N/C auxiliary contact. LC1 Fppp: 3 poles. To add auxiliary contacts or other accessories, please consult our specialist catalogue Motor-starter solutions. Control and protection components. (4) Replace pp with the control circuit voltage reference indicated in the table below. Volts a 24 48 110 220 230 240 LC1 D 50 Hz B5 E5 F5 M5 P5 U5 60 Hz B6 E6 F6 M6 U6 50/60 Hz B7 E7 F7 M7 P7 U7 LC1 F115F225 50 Hz (LX1 coil) B5 E5 F5 M5 P5 U5 60 Hz (LX1 coil) E6 F6 M6 U6 40400 Hz (LX9 coil) E7 F7 M7 P7 U7 LC1 F265F330 40400 Hz (LX1 coil) B7 E7 F7 M7 P7 U7 LC1 F400F630 40400 Hz (LX1 coil) E7 F7 M7 P7 U7 LC1 F800 40400 Hz (LX1 coil) FE7 P7 P7 P7 For other voltages available between 24 V and 660 V, or a DC control circuit, please consult your Regional Sales Office.

NS160HMAppp + LC1 D115pp + ATV 71HD45N4

132

Global Catalog. Refer to Statement of Scope on page 2.

Combinations for customer assembly


(continued)

Variable speed drives for asynchronous motors


Altivar 71
Motor starters: supply voltage 440480 V

533345

3-phase supply voltage 440480 V 50/60 Hz


Motor Power (1) kW 0.75 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 220 250 280 315 355 400 HP 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400 450 500 600 ATV 71H075N4 ATV 71HU15N4 ATV 71HU22N4 ATV 71HU30N4 ATV 71HU40N4 ATV 71HU55N4 ATV 71HU75N4 ATV 71HD11N4 ATV 71HD15N4 ATV 71HD18N4 ATV 71HD22N4 ATV 71HD30N4 ATV 71HD37N4 ATV 71HD45N4 ATV 71HD55N4 ATV 71HD75N4 ATV 71HD90N4 ATV 71HC11N4 ATV 71HC13N4 ATV 71HC16N4 ATV 71HC20N4 ATV 71HC25N4 ATV 71HC25N4 ATV 71HC28N4 ATV 71HC31N4 ATV 71HC40N4 ATV 71HC40N4 GV2 L08 GV2 L10 GV2 L14 GV2 L14 GV2 L16 NS80HMA50 NS80HMA50 NS80HMA50 NS80HMA50 NS100pMA50 NS100pMA50 NS100pMA100 NS100pMA100 NS160pMA100 NS160pMA150 NS160pMA150 NS160pMA150 NS250pMA220 NS250pMA220 NS400pSTR43ME NS400pSTR43ME NS400pSTR43ME NS630pSTR43ME NS630pSTR43ME NS630pSTR43ME NS630pSTR43ME Drive Catalog number Circuit-breaker Catalog number (2) Rating Im A 4 6.3 10 10 14 50 50 50 50 50 50 100 100 100 150 150 150 220 220 320 320 320 500 500 500 500 A 300 300 300 300 300 300 600 600 600 1350 1350 1350 1980 1980 2880 2880 2880 4500 4500 4500 4500 LC1 D18pp LC1 D18pp LC1 D18pp LC1 D18pp LC1 D18pp LC1 D25pp LC1 D40pp LC1 D40pp LC1 D50pp LC1 D50pp LC1 D65pp LC1 D65pp LC1 D80pp LC1 D115pp LC1 D115pp LC1 D115pp LC1 D115pp LC1 F185pp LC1 F225pp LC1 F265pp LC1 F330pp LC1 F400pp LC1 F400pp LC1 F500pp LC1 F500pp LC1 F630pp Line contactor Catalog number (3) (4)

Type 2 coordination

533346

105517_18

Type 1 coordination
NS800 MicroLogic 800 1600 LC1 F630pp 2 or 5 (LR OFF) 500 800 ATV 71HC50N4 NS1000 MicroLogic 1000 2000 LC1 F800pp 2 or 5 (LR OFF) (1) Standard power ratings for 4-pole motors 50/60 Hz 400 V. The values expressed in HP comply with the NEC (National Electrical Code). (2) NS800HMA, NSpppp, NS800, NS1000: products sold under the Merlin Gerin brand. For catalog numbers to be completed, replace the dot with the letter corresponding to the circuit-breaker performance (N, H, L). Breaking capacity of circuit-breakers according to standard IEC60947-2: Circuit-breaker Icu (kA) for 440 V N H L GV2 L08, GV2 L10 100 GV2 L14 20 NS80HMA 65 NS100pMA, NS160pMA, NS250pMA 35 65 130 NS400p, NS630p 42 65 130 NS800, NS1000 50 65 130 (3) Composition of contactors: LC1 D18 to LC1 D115: 3 poles + 1 N/O auxiliary contact and 1 N/C auxiliary contact. LC1 Fppp: 3 poles. To add auxiliary contacts or other accessories, please consult our specialist catalogue Motor-starter solutions. Control and protection components. (4) Replace pp with the control circuit voltage reference indicated in the table below. Volts a 24 48 110 220 230 240 LC1 D 50 Hz B5 E5 F5 M5 P5 U5 60 Hz B6 E6 F6 M6 U6 50/60 Hz B7 E7 F7 M7 P7 U7 LC1 F115F225 50 Hz (LX1 coil) B5 E5 F5 M5 P5 U5 60 Hz (LX1 coil) E6 F6 M6 U6 40400 Hz (LX9 coil) E7 F7 M7 P7 U7 LC1 F265F330 40400 Hz (LX1 coil) B7 E7 F7 M7 P7 U7 LC1 F400F630 40400 Hz (LX1 coil) E7 F7 M7 P7 U7 LC1 F800 40400 Hz (LX1 coil) FE7 P7 P7 P7 For other voltages available between 24 V and 660 V, or a DC control circuit, please consult your Regional Sales Office.

NS160HMA + LC1 D115pp + ATV 71HD55N4

Global Catalog. Refer to Statement of Scope on page 2.

133

Mounting and installation recommendations

Variable speed drives for asynchronous motors


Altivar 71

Mounting recommendations
Depending on the conditions in which the drive is to be used, its installation will require certain precautions and the use of appropriate accessories. Install the unit vertically: b Do not place it close to heating elements. b Leave sufficient free space to ensure that the air required for cooling purposes can circulate from the bottom to the top of the unit.
ATV 71HpppM3, ATV 71HD11M3XHD45M3X, ATV 71H075N4HD75N4

u 100

522085

Mounting types b Mounting A

u 100

10

50

50

Removing the protective blanking cover for: ATV 71HpppM3, ATV 71HD11M3X, HD15M3X, ATV 71HD075N4HD18N4

b Mounting B

564510

b Mounting C
Removing the protective blanking cover for: ATV 71HD18M3XHD45M3X, ATV 71HD22N4HD75N4

u 50

u 50

By removing the protective blanking cover from the top of the drive, the degree of protection for the drive becomes IP 20. The protective blanking cover may vary according to the drive model, see opposite.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 107

Wiring diagrams: pages 114 to 129

134

Global Catalog. Refer to Statement of Scope on page 2.

Mounting and installation Variable speed drives recommendations (continued) for asynchronous motors
Altivar 71

Mounting recommendations (continued)


Derating curves The derating curves for the drive nominal current (In) depend on the temperature, the switching frequency and the mounting type.
ATV 71H037M3HD15M3X and ATV 71H075N4HD18N4
I/In %

In = 100 90 80 70 60 50
40oC mounting A 50oC mountings B and C 50oC mounting A 60oC mountings A, B and C

12

16 kHz

Switching frequency

ATV 71HD22N4 and ATV 71HD30N4 (1)


I/In %

In = 100 90 80 70 60 50
60oC mountings A, B and C 50oC mountings A, B and C 40oC mountings A, B and C

12 16 kHz Switching frequency

ATV HD18M3XHD45M3X and ATV 71HD37N4HD75N4 (1)


I/In

% In = 100 90 80 70 60 50
60oC mountings A, B and C 50oC mountings A, B and C 40oC mountings A, B and C

2,5

12 16 kHz Switching frequency

For intermediate temperatures (55C for example) interpolate between 2 curves.


(1) Above 50C, ATV 71HD18M3X, HD22M3X, ATV 71HD30N4HD75N4 drives should be fitted with a control card fan kit. See page 22. Presentation: pages 6 to 9 Characteristics: pages 10 to 15 Catalog numbers: pages 20 and 21 Dimensions: pages 92 to 107 Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

135

Mounting and installation Variable speed drives recommendations (continued) for asynchronous motors
Altivar 71

Mounting recommendations (continued)


ATV 71HD55M3X, HD75M3X, ATV 71HD90N4HC50N4

10 h
ATV 71H h D55M3X, D90N4, C11N4 100 HC13N4, HC16N4 250 HC20N4HC28N4 300 HC31N4HC40N4 450 HC50N4 550 These drives can be mounted side by side, observing the following mounting recommendations:

400

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

400

1000

Dimensions: pages 92 to 107

Wiring diagrams: pages 114 to 129

136

Global Catalog. Refer to Statement of Scope on page 2.

Mounting and installation Variable speed drives recommendations (continued) for asynchronous motors
Altivar 71

Mounting recommendations (continued)


Derating curves The derating curves for the drive nominal current (In) depend on the temperature, the switching frequency and the mounting type.

For intermediate temperatures (55C for example), interpolate between 2 curves.

ATV 71HD55M3X, HD75M3X


% 120 In = 100 90

ATV 71HD90N4
% 120 110 In = 100

80 67 60

40 C 50 C

70 60 50 40 30 50 C

40

60 C

20 60 C 0 2 2,5 3 4 5 6 7 8 kHz Switching frequency 2 2,5 3 4 5 6 7 8 kHz Switching frequency

ATV 71HC11N4
% 120 109 In = 100 80 70 60 50 C

ATV 71HC13N4
% 120 107 In = 100 40 C 50 C 60 60 C

40 C

78

40

60 C

40

20 0 2 2,5 3 4 5 6 7 8 kHz Switching frequency

20 0 2 2,5 3 4 5 6 7 8 kHz Switching frequency

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 107

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

137

Mounting and installation Variable speed drives recommendations (continued) for asynchronous motors
Altivar 71

Mounting recommendations (continued)


Derating curves
ATV 71HC16N4
% 120 111 In = 100

ATV 71HC20N4
% 120 109 In = 100 80 40 C 50 C 72 60 50 C

80 71 60

40 C

40

60 C

40

60 C

20

20

0 2 2,5 3 4 5 6 7 8 kHz Switching frequency 2 2,5 3 4 5 6 7 8 kHz Switching frequency

ATV 71HC25N4 combined with a 220 kW motor


% 120 110 In = 100

ATV 71HC25N4 combined with a 250 kW motor


% 120 108 In = 100 80 77 60 60 C

80 72 60

40 C 50 C 60 C

40 C 50 C

40

40

20

20

2,5 3

6 7 8 kHz Switching frequency

2,5

6 7 8 Switching frequency

kHz

ATV 71HC28N4
% 120 107 In = 100 81

ATV 71HC31N4
% 120 110 In = 100 40 C 50 C

80 72 60

40 C 50 C 60 C

60 60 C 40

40

20

20

2,5

6 7 8 kHz Switching frequency

2,5

6 7 8 kHz Switching frequency

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 107

Wiring diagrams: pages 114 to 129

138

Global Catalog. Refer to Statement of Scope on page 2.

Mounting and installation Variable speed drives recommendations (continued) for asynchronous motors
Altivar 71

Mounting recommendations (continued)


Derating curves
ATV 71HC40N4 combined with a 355 kW motor
% 120 109 In = 100 80 76 60 40

ATV 71HC40N4 combined with a 400 kW motor


% 120 107 In = 100 80

40 C 50 C

40 C 50 C 60 C

60 60 C 40

20 0 2 2,5 3 4 5 6 7 8 kHz Switching frequency

20 0 2 2,5 3 4 5 6 7 8 kHz Switching frequency

ATV 71HC50N4
% 120 108 In = 100

79

40 C 50 C 60 C

60

40

20

0 2 2,5 3 4 5 6 7 8 kHz
Switching frequency

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 107

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

139

Mounting and installation Variable speed drives recommendations (continued) for asynchronous motors
Altivar 71

Specific recommendations for mounting in an enclosure


Observe the mounting recommendations described on pages 134 to 139. To ensure proper air circulation in the drive: b Fit ventilation grilles b Ensure that there is sufficient ventilation. If there is not, install a forced ventilation unit with a filter. The openings and/or fans must provide a flow rate at least equal to that of the drive fans (see page 141) b Use special filters with IP 54 protection b Remove the blanking cover from the top of the drive (see page 134)

Power dissipated inside the enclosure


For drives Dissipated power (1) Mounted in the enclosure W Dust and damp proof flush-mounted W 25 28 30 38 38 42 52 60 73 76 119 124 157 166 184 154 154

3-phase supply voltage: 200240 V 50/60 Hz


ATV 71H037M3 ATV 71H075M3 ATV 71HU15M3 ATV 71HU22M3 ATV 71HU30M3 ATV 71HU40M3 ATV 71HU55M3 ATV 71HU75M3 ATV 71HD11M3X ATV 71HD15M3X ATV 71HD18M3X ATV 71HD22M3X ATV 71HD30M3X ATV 71HD37M3X ATV 71HD45M3X ATV 71HD55M3X ATV 71HD75M3X 46 66 101 122 154 191 293 363 566 620 799 865 1134 1337 1567 1715 2204

3-phase supply voltage: 380480 V 50/60 Hz


ATV 71H075N4 44 26 ATV 71HU15N4 64 28 ATV 71HU22N4 87 30 ATV 71HU30N4 114 35 ATV 71HU40N4 144 40 ATV 71HU55N4 178 50 ATV 71HU75N4 217 55 ATV 71HD11N4 320 65 ATV 71HD15N4 392 86 ATV 71HD18N4 486 86 ATV 71HD22N4 717 110 ATV 71HD30N4 976 135 ATV 71HD37N4 1174 137 ATV 71HD45N4 1360 165 ATV 71HD55N4 1559 178 ATV 71HD75N4 2326 225 ATV 71HD90N4 2403 237 ATV 71HC11N4 2726 261 ATV 71HC13N4 3191 296 ATV 71HC16N4 3812 350 ATV 71HC20N4 4930 493 ATV 71HC25N4 5873 586 ATV 71HC28N4 6829 658 ATV 71HC31N4 7454 772 ATV 71HC40N4 9291 935 ATV 71HC50N4 11345 1116 (1) This value is given for operation at nominal load and for a switching frequency of 2.5 or 4 kHz depending on the rating. Add 7 W to this value for each additional option card.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 107

Wiring diagrams: pages 114 to 129

140

Global Catalog. Refer to Statement of Scope on page 2.

Mounting and installation Variable speed drives recommendations (continued) for asynchronous motors
Altivar 71

Fan flow rate depending on the drive rating


For drive ATV 71H037M3 HU15M3, ATV 71H075N4 HU22N4 ATV 71HU22M3 HU40M3, ATV 71HU30N4, HU40N4 ATV 71HU55M3, ATV 71HU55N4, HU75N4 ATV 71HU75M3, ATV 71HD11N4 ATV 71HD11M3X, HD15M3X ATV 71HD15N4, HD18N4 ATV 71HD18M3X, HD22M3X, ATV 71HD22N4 ATV 71HD30N4, HD37N4 ATV 71HD30M3X HD45M3X ATV 71HD45N4 HD75N4 ATV 71HD55M3X, ATV 71HD90N4 ATV 71HD75M3X, ATV 71HC11N4 ATV 71HC13N4 ATV 71HC16N4 ATV 71HC20N4 HC28N4 ATV 71HC31N4, HC40N4 ATV 71HC50N4 Flow rate m3/hour 17 56 112 163 252 203 203 406 406 402 774 745 860 1260 2100 2400

Sealed metal enclosure (IP 54 degree of protection) The drive must be mounted in a dust and damp proof casing in certain environmental conditions: dust, corrosive gases, high humidity with risk of condensation and dripping water, splashing liquid, etc. This enables the drive to be used in an enclosure where the maximum internal temperature reaches 50C.

Calculating the enclosure dimensions


Maximum thermal resistance Rth (C/W) = maximum temperature inside enclosure in C e e = maximum external temperature in C Rth = --------------P P = total power dissipated in the enclosure in W Power dissipated by drive: see page 140 (mounting in an enclosure or flush-mounting in an enclosure). Add the power dissipated by the other equipment components. Useful heat dissipation surface of enclosure S (m2) (sides + top + front panel if wall-mounted) K S = --------Rth K = enclosure thermal resistance per m2

For a metal enclosure: b K = 0.12 with internal fan b K = 0.15 without fan
Note: Do not use insulated enclosures, as they have a poor level of conductivity.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 107

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

141

Combinations

Variable speed drives for asynchronous motors


Altivar 71

Compatible combinations of functions and applications


Applications Machines Hoisting Cranes, overhead cranes, gantries (vertical hoisting, translation, slewing), lifting platforms Lift Retrofit lifts up to 1.2 ms Material handling Palletizers/depalletizers, carton packers, labelling machines, conveyors, roller tables

Motor control functions Flux vector control with and without sensor 2-point vector control Open-loop synchronous motor ENA system Voltage/frequency ratio Output frequency 1000 Hz Motor overvoltage limiting Application functions Differential bipolar reference Reference delinearization (magnifying glass effect) Frequency control input Operations on the references (summing, subtraction, multiplication) Brake control Brake feedback via contact High-speed hoisting Load measurement Load sharing Limit switch management S ramp Current limiting Output contactor command Integrity check of output contactor Rescue following power failure Stop on thermal alarm Torque control Torque limit Motor fluxing Parameter set switching Motor switching Position control via limit switches Uncontrolled output cut Detection of current or torque limit PID regulator Auto/man Reference storage +/- speed, single action button +/- speed, double action button +/- speed around a reference Traverse control Automatic catching a spinning load with speed detection (catch a spinning load) Undervoltage management Fastest possible stop

b b

b b b b b b b b b b b b b b b b b b

b b b b b b b b b b b b b b b b b b

b b b

b Frequent or necessary use


Presentation: pages 6 to 9 Characteristics: pages 10 to 15 Catalog numbers: pages 20 and 21 Dimensions: pages 92 to 107 Wiring diagrams: pages 114 to 129

142

Global Catalog. Refer to Statement of Scope on page 2.

(For other functions that can be used for all applications, see pages 154 to 175)
Packing Palletizers/depalletizers, carton packers, labelling machines Textiles Weaving looms, carding frames, washing machines, spinners, drawing frames Wood Automatic lathes, saws, milling High inertia Centrifuges, mixers, unbalanced machines (beam pumps, presses) Process Sectional production lines (speed < 500 m/min) Example: building materials

b b b

b b

b b

b b b

b b b b

b b

b b

b b b b b b b b

b b

b b b

b b b b b b

b b b b b b b b b b b b

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 107

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

143

Functions

Variable speed drives for asynchronous motors


Altivar 71

Summary of functions
Remote graphic display terminal functions
Description Navigation Password page 146 page 147 page 147

Integrated 7-segment display terminal


Presentation page 148

Start-up
Simply Start menu Programming using macro-configurations MONITORING menu page 148 page 149 page 150

Configuration and settings


Presentation page 150

Operation
Presentation page 150

Maintenance, diagnostics
Response to faults or alarms Fault log and help IDENTIFICATION menu Test functions Oscilloscope function page 151 page 151 page 151 page 151 page 151

Controlling the drive


Via the drive I/O Via the remote graphic display terminal Via a communication network page 152 page 152 page 153

Application functions
2-wire control - State detection - Transition detection - Forward operation as priority 3-wire control Phase rotation Ramps Time Profile (linear, S, U) Switching Automatic adaptation page 154 page 154 page 154 page 154 page 154 page 154 page 155 page 155 page 155 page 156 page 156 page 156 page 157 page 157 page 157 page 157 page 157 page 157 page 158 page 158 page 158 page 158 page 158 page 159 page 159 page 159 page 159 page 159 page 159 page 159

Preset speeds Jog operation Limiting low speed operating time Motor control type - Flux vector control with sensor - Sensorless flux vector control - 2-point vector control - Voltage/frequency ratio - ENA system - Synchronous motor Using an incremental encoder Encoder tests Limiting motor overvoltage Auto-tuning Switching frequency, noise reduction Motor fluxing Brake control - Movement type - Brake feedback via contact - Brake release pulse - Brake engage on reversal of operating direction - Brake engage request time delay - Automatic DC injection Presentation: pages 6 to 9 Characteristics: pages 10 to 15 Catalog numbers: pages 20 and 21 Dimensions: pages 92 to 113 Wiring diagrams: pages 114 to 129

144

Global Catalog. Refer to Statement of Scope on page 2.

Functions

Variable speed drives for asynchronous motors


Altivar 71

Summary of functions (continued)


Application functions (continued) Limit switch management High-speed hoisting External weight measurement Load sharing Output contactor - Control - Integrity check Stop on thermal alarm Evacuation following power failure Uncontrolled output cut +/- speed - Single action buttons - Double action buttons - Reference saving - Around a reference Spooling - Traverse control - Counter wobble Automatic catching of a spinning load with speed detection Undervoltage management Braking balance Braking resistor thermal protection Parameter set switching Motor or configuration switching Position control via limit switches Short and long cam operation Reference switching Operations on the references - Summing inputs - Subtraction inputs - Multiplication inputs PID regulator - Preset PID reference - Predictive speed reference - Auto/man Torque control Torque limit Torque or current limit detection Current limit Reference saving Stop types - Freewheel stop - Fast stop - Fastest possible stop - DC injection stop Motor thermal protection Drive thermal protection IGBT thermal protection Configuring the drives fault response Resetting resettable faults General reset (disables all faults) Automatic restart PTC probe protection IGBT testing Resetting operating time to zero External fault Line contactor control Forced local mode
page 159 page 160 page 161 page 161 page 161 page 161 page 161 page 161 page 162 page 162 page 162 page 163 page 163 page 163 page 164 page 164 page 165 page 165 page 165 page 165 page 165 page 166 page 166 page 167 page 167 page 167 page 167 page 168 page 168 page 168 page 169 page 170 page 170 page 170 page 171 page 171 page 171 page 171 page 171 page 172 page 172 page 172 page 173 page 173 page 173 page 174 page 174 page 174 page 174 page 174 page 175 page 175

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

145

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

Remote graphic display terminal functions


522148

This display terminal is attached to the front of the drive. It includes the integrated 7-segment display terminal for drives supplied without a graphic display terminal. 1 b Description v Description of graphic display terminal 1 Graphic display unit: - 8 lines, 240 x 160 pixels - large digit display that can be read from 5 m away - bar chart display 2 Assignable functions keys F1, F2, F3, F4: - dialogue functions: direct access, help screens, navigation - application functions: Local/Remote, preset speed. 3 STOP/RESET key: local control of motor stopping/fault clearing 4 RUN key: local control of motor operation 5 Navigation button: - Press to save the current value (ENT) - Turn to increase or decrease the value, go to the next or previous line 6 FWD/REV key: reverses the direction of rotation of the motor 7 ESC key: aborts a value, parameter or menu to return to the previous option. Note: Keys 3, 4 and 6 can be used to control the drive directly. v Description of graphic display unit 1 Display line. Its content can be configured; the factory settings show: - the drive status (e.g. RUN) - the active control channel (e.g. Term: terminals) - the frequency reference - the current in the motor 2 Menu line. Indicates the current menu or submenu. 3 Area displaying menus, submenus, parameters, values, bar charts, in the form of a scrolling window, with a maximum of 5 lines. The line or value selected using the navigation button is displayed in reverse video (see opposite). 4 Section displaying the functions assigned to the keys F1 to F4 and aligned with them, for example: - >> : Horizontal scrolling to the right, or proceeding to the next menu or submenu, or, in the case of a value, decreasing the value, displayed in reverse video (see example opposite) - << : Horizontal scrolling to the left, or proceeding to the next menu or submenu, or, in the case of a value, increasing the value, displayed in reverse video - Quick: Rapid access to a parameter from any screen when the Quick function is displayed above the F4 key - HELP: Contextual help - Code: Displays the selected parameter code - Other functions (application functions) can be assigned to these keys via the 1.6 COMMAND menu. 5 : Means that this display window does not scroll further down. : Means that this display window can scroll further down. 6 : Means that this display window can scroll further up. : Means that this display window does not scroll further up.

2 3 4 7 6

522149

1 2

RUN

Term

+50.00Hz

5.4A
6

1. DRIVE MENU 1.1 SIMPLY START 1.2 MONITORING

1.3 SETTINGS 1.4 MOTOR CONTROL 1.5 INPUTS / OUTPUTS CFG

Code
F1

<<
F2

>>
F3

Quick
F4

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

146

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

Remote graphic display terminal functions (continued)


b Navigation: accessing menus and parameters Structure of main menus: 1 Drive menu:
Menu type Function
522150

ATV71HU22N4
2.2kW/3HP 380/480V Config n1

1.1 SIMPLY START 1.2 MONITORING

1.3 SETTINGS 1.4 MOTOR CONTROL

RUN

Term

+50.00Hz

5.4A

1. DRIVE MENU

1.1 SYMPLY START 1.2 MONITORING 1.3 SETTINGS 1.4 MOTOR CONTROL 1.5 INPUTS / OUTPUTS CFG

1.5 INPUTS/OUTPUTS CFG 1.6 COMMAND 1.7 APPLICATION FUNCT. 1.8 FAULT MANAGEMENT 1.9 COMMUNICATION 1.10 DIAGNOSTICS 1.11 IDENTIFICATION 1.12 FACTORY SETTINGS 1.13 USER MENU 1.14 PROGRAMMABLE CARD

Code

<<

>>

Quick

RUN

Term

+43.33Hz 5.4A

Motor speed

1300 rpm
Min=0 Max=1500 Quick

Simplified menu for a quick start-up Displays current values for motor, inputs/outputs and communication (command words, status words, etc.) Accesses the adjustment parameters, which can be modified during operation Accesses the motor parameters, including adjustment of motor control profiles Configures the I/O and transforms signals Configures the command and reference channels Configures the application functions (preset speeds, PID regulator, etc.) Configures the fault management process Configures the communication networks Provides diagnostics for motor and drive, integrated test procedures, fault log Identifies the drive and the internal options Restores factory settings (completely or by parameter group) Accesses the parameters selected by the user Accesses the parameters for the Controller Inside programmable card

2 Display line 3 Display screen: Displays values in the form of bar charts or digital values, depending on the extent of customization.

RUN

Term

+0.00Hz

0A

4 Main menu:
Menu type Function

MAIN MENU
1. DRIVE MENU 2. LEVEL ACCESS 3. OPEN / SAVE AS 4. PASSWORD 5. LANGUAGE

1. DRIVE MENU 2. ACCESS LEVEL 3. OPEN/SAVE AS 4. PASSWORD 5. LANGUAGE 6. MONITORING CONFIG. 7. DISPLAY CONFIG.

<<

>>

Quick

See above (1 Drive menu) 4 access levels: basic, limited, advanced, expert Transfers files between the graphic display terminal and the drive Provides password protection for the configuration Choice of 6 languages available (English, German, Spanish, French, Italian and Chinese) Customizes the display line 2 and the display screen 3 (bar charts, digital values) Configures how parameters are displayed: customization, selection for User menu, visibility, accessibility

b Password Altivar 71 drives allow individual parameters to be selected for password protection. Rights can be set for save operations and for loading the configuration.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

147

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

Integrated 7-segment display terminal


ATV 71pppppM3, ATV 71HD11M3X, HD15M3X and ATV 71H075N4HD15N4 drives can be supplied without a graphic display terminal. In this case, they are equipped with an integrated 7-segment display terminal. This can be used to: v Display status and faults v Access and modify parameters

Start-up
The Altivar 71 drive is supplied ready for use for most applications. When the drive is switched on, the menus for setting the language and access level appear automatically.
522151

RUN

Term
:

+50.00Hz

5.4A
2 wire

1.1 SIMPLY START 2/3 wire control Macro-configuration : Standard mot. Freq. : Rated motor power : Rated motor volt. : M. handling 50Hz IEC 2.2kW 400V

Code

<<

>>

Quick

b Simply start menu By accessing the Simply start menu directly it is possible to: v Pre-program the drive for an application: - Select the relevant macro-configuration - 2-wire/3-wire control v Benefit from optimum motor performance: - Enter data from the motor rating plate - Auto-tuning. v Protect the motor by setting the drives integrated electronic thermal overload relay

Simply start menu

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

148

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

Start-up (continued)
b Programming using macro-configurations Programming using macro-configurations offers the choice of seven options corresponding to the various business areas and applications: v Start/stop v Material handling v General use v Hoisting v PID regulation v Communication network connectivity v Master/slave applications Choosing one of these macro-configurations automatically assigns the functions, parameters and I/O, even in the case of option cards. Although the configuration is preset, it can still be modified, if necessary. The Start/stop macro-configuration is set as the factory configuration. The preset functions for each macro-configuration are given in the table below.
Type of macro-configuration Start/stop Material handling General use Hoisting PID regulation Communication Master/slave network application connectivity Ref. 2 channel Ref. 1 channel by bus Not assigned Motor freq. Forward Reverse Ref 2 switch Fault reset Not assigned Not assigned Stop Forward Reverse Ref 2 switch Fault reset Not assigned Faulty Not assigned Ref. 1 channel

Altivar 71 drive I/O


AI1 Ref. 1 channel Ref. 1 channel Ref. 1 channel Ref. 1 channel PID reference

AI2 AO1 2-wire LI1 LI2 LI3 LI4 LI5 LI6 3-wire LI1 LI2 LI3 LI4 LI5 LI6 R1 R2

Not assigned Motor freq. Forward Reverse Not assigned Not assigned Not assigned Not assigned Stop Forward Reverse Not assigned Not assigned Not assigned Faulty Not assigned

Sum ref. 2 Motor freq. Forward Reverse 2 preset speeds 4 preset speeds 8 preset speeds Fault reset Stop Forward Reverse 2 preset speeds 4 preset speeds 8 preset speeds Faulty Not assigned

Sum ref. 2 Motor freq. Forward Reverse JOG Fault reset Torque limit Not assigned Stop Forward Reverse JOG Fault reset Torque limit Faulty Not assigned

Not assigned Motor freq. Forward Reverse Fault reset Ext fault Not assigned Not assigned Stop Forward Reverse Fault reset Ext fault Not assigned Faulty Brk control

PID feedback Motor freq. Forward Reverse PID integral reset PID 2 preset ref. PID 4 preset ref. Not assigned Stop Forward Reverse PID integral reset PID 2 preset ref. PID 4 preset ref. Faulty Not assigned

Torque ref. 2 channel Signed torque Forward Reverse Trq/spd switching Fault reset Not assigned Not assigned Stop Forward Reverse Trq/spd switching Fault reset Not assigned Faulty Not assigned

I/O extension card I/O


2-wire LI7 3-wire LI7 LI8 to LI14 LO1 to LO4 R3/R4 AI3, AI4 RP AO2 AO3 Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Motor current Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Motor current Signed torque Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Motor current Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Motor current Signed torque Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Motor current PID error Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Motor current Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Not assigned Motor current Motor freq.

Graphic display terminal keys


F1 key Not assigned Not assigned Not assigned Not assigned Not assigned Control Not assigned via graphic display terminal Not assigned Not assigned

F2, F3, F4 keys

Not assigned

Not assigned

Not assigned

Not assigned

Not assigned

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

149

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

Start-up (continued)
b MONITORING menu The MONITORING menu can be used to display commands, the operation of the motor and application through the drive of its I/O or of the communication network connections.
522169

RUN

Term
: : : :

+43.33Hz

5.4A
43.3 Hz 5.4 A

RUN
PR

Term
LI1 LI2

+50.00Hz
LI3 LI4 LI5

80A
LI6

RUN

Mod.
: : : :

+50.00Hz

5.4A
Modbus

1.2 MONITORING Frequency Ref. Motor current Motor speed Drv thermal state
1 0 1 0

Logic input map

COMMUNICATION MAP Cmd channel Cmd Value ABCD Hex CANopen +50.00 Hz 2153 Hex

1300 rpm 80 % 85 %

LI7

LI8

LI9

LI10 LI11 LI12 LI13 LI14

Active ref. channel : Frenquency ref. ETA status word

Motor thermal state :

Code

<<

>>

Quick

<<
Logic input map

>>

Quick

Code

<<

>>

Quick

Displaying physical values

Communication map

Configuration and settings


The SETTINGS menu can be used to configure all the drives settings. Activating a function automatically provides access to the related settings on the same screen (the application functions are described on pages 154 to 175).
522154

RUN

Term

+50.00Hz 1250A
0,01 3,00 s 3,00 s 5,00 s 5,00 s

RDY

Term
: : : :

+0.00Hz

0.0A
LI3 LI4 LI5 NO 10.0 Hz

RDY

Term

+0.00Hz

0A

1.3 SETTINGS Ramp increment : Acceleration Deceleration Acceleration 2 Deceleration 2 : : : :

PRESET SPEEDS 2 preset speeds 4 preset speeds 8 preset speeds Preset speed 2

ACCELERATION

16 preset speeds :

9.51 s
Min=0,01 Max=9999

Code << Settings screen

>>

Quick

Code

<<

>>

Quick

<<

>>

Quick

Setting a function

Configuring a value

Operation
The display screen appears automatically every time the drive is turned on. There are different possible scenarios: b One or two bar charts are displayed. b One, two or five digital values are displayed.
533525

RUN

Term

+43.33Hz 5.4A

DEC

Term

+38.0Hz

10A

RUN

Term
: : : :

+43.33Hz

5.4A
43.3 Hz 5.4 A

Motor speed

Output frequency

1.2 MONITORING Frequency Ref. Motor current

1300 rpm
Min=0
1 bar chart

+45.1 Hz
<<
1 digital value

Motor speed Drv thermal state

1300 rpm 80 % 85 %

Motor thermal state :

Max=1500 Quick

>>

Quick

Code

<<

>>

Quick

5 digital values

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

150

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

Maintenance, diagnostics
533523.

SCF1

Term

+50.00Hz

0.0A

FAULT HISTORY Short circuit Overcurrent External FLT Overvoltage Undervoltage

New functions have been added to the Altivar 71 drive to enable it to provide quick and simple maintenance, ultimately boosting productivity: b Response to faults or alarms It is possible to use the alarm management or drive operation configuration functions to take corrective measures before stopping the machine.

Help
Fault log
522162

Quick

SCF1

Term

+50.00Hz

0.0A

MOTOR SHORT CIRCUIT Check the connection cables and the motor insulation. Perform the diagnostic test.

b Fault log and help When a fault occurs, a help screen is available to quickly identify the cause of the fault. As soon as the fault occurs, values such as speed, current, thermal state, timer are saved and restored in the fault log. The last 8 faults are stored.

Quick
Troubleshooting screen

522163

RUN

Term

+50.00Hz

5.4A

1.11 IDENTIFICATION ATV71HU22N4 2.2 kW / 3HP 380 / 480 V Appl. Software V1.0 IE 01 MC Software V1.0 IE 01

b IDENTIFICATION menu The IDENTIFICATION menu can be used to display the relevant serial numbers and software versions, thereby helping to manage the equipment base. This information, also available from the PowerSuite software workshop, can be exported to other database-type software applications.

<<

>>

Quick

Identification screen

522157

RUN

Term

+50.00Hz

5.4A

SERVICE MESSAGE For technical support, dial 32 12 75

b Test functions The Altivar 71 drive includes the following test functions: v Identifying any motor short-circuit before start-up v Running, via the graphic display terminal or PowerSuite software workshop, automatic procedures during maintenance operations aimed at testing: - the motor - the drive power components The test results are shown on the graphic display terminal or using the PowerSuite software workshop. It is also possible to write and read messages in the drive using the graphic display terminal or the PowerSuite software workshop. b Oscilloscope function The Altivar 71 drive has an oscilloscope function, which produces traces that can be viewed using the PowerSuite software workshop. The PowerSuite software workshop can also be used to carry out remote diagnostics via modem.

Quick
Example of a customized message

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

151

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

Controlling the drive


b Via the drive I/O Control signals are transmitted via cable to the I/O. Functions are assigned to logic inputs, analog inputs, etc. A logic input can be assigned to more than one function. This means that two functions can be controlled using a single signal, thereby limiting the number of inputs required. The Altivar 71 drive I/O can be configured independently from each other. For instance, v A time delay can be applied when it comes to reading the logic inputs, so as to avoid any bounce-back from certain switches. v Transforming incoming signals on the analog inputs can help the drive fully adapt to the control devices and applications: - minimum and maximum values for the input signal - input filtering in order to eliminate unwanted interference from the signals received - magnifying glass effect through delinearizing the input signal in order to increase the precision with small amplitude signals - Pedestal and Deadband functions for signals in order to prevent low speed operations which can have an adverse effect on the application - Mid-point function, which can be used from a unipolar input signal to obtain a bipolar output signal to control the speed and direction of rotation v Transforming analog outputs which transfer information sent by the drive to other devices (display units, drives, PLCs, etc.): - voltage or current output signal - minimum and maximum values for the output signal - output signal filtering Logic outputs can be delayed on activation and deactivation. The output state can also be configured when the signal is active. The frequency control signals are also transformed by the drive: v signal frequency minimum and maximum values (30 kHz on the extended I/O cards RP input, 300 kHz maximum on the encoder interface card input). b Via the remote graphic display terminal The rotation commands and references (torque, speed or PID) can be controlled via the graphic display terminal. Some application functions can also be assigned to the function keys F1, F2, F3 and F4 on the graphic display terminal. It is possible to manage a change in command and/or reference source (bumpless function) in different ways. For example, two options are offered when switching control from via the terminals to via the graphic display terminal: v stop the Altivar 71 drive, or v continue operation with a copy of the direction of rotation and reference

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

152

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

Controlling the drive (continued)


b Via a communication network v I/O profile The I/O profile, which is easy and quick to use, can be used to control the Altivar 71 drive via the communication network, in the same way as via the I/O terminals. When commands are sent via a network they are written in a command word. This word behaves like virtual terminals containing logic inputs. Application functions can be assigned to the bits of this word. More than one function can be assigned to the same bit. The commands and references can come from different sources, such as the terminals, graphic display terminal or communication networks. Each source can be set or switched individually using logic inputs or command word bits. The I/O profile is supported by all integrated communication ports (Modbus, CANopen), as well as by all the communication cards available (Ethernet TCP/IP, Fipio, Profibus DP, etc.). v CiA DSP 402 profile (CANopen Device Profile Drives and Motion Control) This profile from the organization CiA (CAN in Automation) describes standard functions, parameters and operation for variable speed drives. This standard is an extension of the DRIVECOM profile. The Altivar 71 drive complies with the CiA DSP 402 standard and it supports the following 2 modes in this profile: separate and not separate. Separate mode The Start/Stop commands and references can come for different sources. For example, the speed reference is transmitted by the Ethernet TCP/IP network and the Start/Stop commands by the logic signals wired on the terminals. Each source can be set or switched individually using logic inputs or command word bits. Not separate mode The Start/Stop commands and references (speed, torque, PID, etc.) come from the same source (e.g. CANopen bus). It is possible to replace this source by another one, using a logic input or command word bit. The CiA DSP 402 profile is supported by all integrated communication ports (Modbus, CANopen), as well as by all the communication cards available (Ethernet TCP/IP, Fipio, Profibus DP, etc.). v ODVA profile The ODVA profile is supported by the DeviceNet communication card.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

153

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

Application functions
b 2-wire control This can be used to control the direction of operation by means of a stay-put contact. It is enabled by means of 1 or 2 logic inputs (non-reversing or reversing). This function is suitable for all non-reversing and reversing applications. 3 operating modes are possible: v detection of the state of the logic inputs v detection of a change in state of the logic inputs v detection of the state of the logic inputs with forward operation always having priority over reverse
Altivar 71 control terminals LI1: forward LIx: reverse

24 V

LI1

LIx

Wiring diagram for 2-wire control

f (Hz)

0
Stop

b 3-wire control This can be used to control the operating and stopping direction by means of pulsed contacts. It is enabled by means of 2 or 3 logic inputs (non-reversing or reversing). This function is suitable for all non-reversing and reversing applications.
Altivar 71 control terminals LI1: Stop LI2: Forward LIx: Reverse

1 0 1
t

Forward

0 1
Reverse 0

24 V

LI1

LI2

LIx

Example of 3-wire control operation

Wiring diagram for 3-wire control

b Phase rotation This function can be used to reverse the direction of rotation without modifying the drive wiring.

RDY

Term

+0.00Hz

0.0A
Linear 0.01 3.92 s 0.54 s 0.0 Hz

RAMP Ramp shape Acceleration Deceleration : Ramp increment : : :

b Ramps v Acceleration and deceleration ramp times This can be used to define acceleration and deceleration ramp times according to the application and the machine dynamics.
f (Hz) FrS f (Hz) FrS

522164

Ramp 2 threshold :

Code
Ramp settings

Quick

0 t1

0 t2

Linear acceleration ramp

Linear deceleration ramp

FrS: Nominal motor frequency t1: Acceleration time t2: Deceleration time t1 and t2 can be set independently from 0.01 to 9999 s (according to one of the following ramp increments: 0.01 s, 0.1 s or 1 s) Factory setting: 3 s.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

154

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

v Acceleration and deceleration ramp profile This can be used to gradually increase the output frequency starting from a speed reference, following a linear profile or a preset profile. In the case of applications involving handling, packaging and passenger transport, the use of S ramps takes up mechanical play and eliminates jolts and also limits non-following of speed during rapid transient operation of high-inertia machines. Selecting linear, S, U or customized profiles assigns both the acceleration and deceleration ramps.
S ramps U ramps Customized ramps
f (Hz) FrS f (Hz) FrS

f (Hz) FrS

f (Hz) FrS

f (Hz) FrS

f (Hz) FrS

0 t2 t1

0 t2 t1

0 t2 t1

t0 t2 t1

0 tA1 tA2 ACC or AC2

0 tA3 tA4 dEC or dE2

FrS: Nominal motor frequency t1: Ramp time set t2 = 0.6 x t1 The curve coefficient is fixed.

FrS: Nominal motor frequency t1: Ramp time set t2 = 0.5 x t1 The curve coefficient is fixed.

FrS: Nominal motor frequency tA1: Can be set between 0 and 100% (of ACC or AC2) tA2: Can be set between 0 and (100% - tA1) (of ACC or AC2) tA3: Can be set between 0 and 100% (of dEC or dE2) tA4: Can be set between 0 and (100% - tA3) (of dEC or dE2) ACC: Acceleration ramp 1 time AC2: Acceleration ramp 2 time dEC: Deceleration ramp 1 time dE2: Deceleration ramp 2 time

f (Hz) HSP AC2 dE2

ACC Forward 1 or 0 reverse 1 LI4 0

dEC

t t

v Ramp switching This can be used to switch 2 acceleration and deceleration ramp times, which can be adjusted separately. Ramp switching can be enabled by: - a logic input - a frequency threshold - a combination of the logic input (or a command word bit) and the frequency threshold - a command word bit Function suitable for: - material handling with smooth starting and approach - machines with fast steady state speed correction v Automatic adaptation of deceleration ramp This can be used to automatically adapt the deceleration ramp if the initial setting is too low when the load inertia is taken into account. This function prevents the drive from locking in the event of an overbraking fault. When this function is active and a short deceleration time has been set, the drive optimizes the motor power supply in order to achieve a high braking torque. Function suitable for all applications which do not need to stop at a precise moment and do not use braking resistors. Automatic adaption must be disabled for machines with a stop position on a ramp and using a braking resistor. This function is automatically disabled if the brake sequence is configured.

Example of switching using logic input LI4


Acceleration 1 (ACC) and deceleration 1 (dEC): - adjustment 0.01 to 9999 s - factory setting 3 s Acceleration 2 (AC2) and deceleration 2 (dE2): - adjustment 0.01 to 9999 s - factory setting 5 s HSP: high speed.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

155

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

RDY

Term
: : : :

+0.00Hz

0.0A
LI3 LI4 LI5 NO 10.0 Hz

PRESET SPEEDS 2 preset speeds 4 preset speeds 8 preset speeds Preset speed 2

16 preset speeds :

b Preset speeds This can be used to switch preset speed references. 2, 4, 8 or 16 preset speeds can be selected. It is enabled by means of 1, 2, 3 or 4 logic inputs. Preset speeds can be set in increments of 0.1 Hz, from 0 Hz to 500 Hz or 1000 Hz, depending on the rating. Function suitable for material handling and machines with several operating speeds.
f (Hz)

522133

Code

<<

>>

Quick

Preset speed settings

20 15 10
LSP

The speed achieved with the LI3 and LI4 inputs at 0 is LSP or reference speed, resulting from the operations carried out on the references. Factory settings: t

Forward 1 or Reverse LI2 0 t

1st speed: LSP (low speed or speed reference) 2nd speed: 10 Hz 3rd speed: 15 Hz 4th speed: 20 Hz

1 LI3 0
t

1 LI4 0
t

Example of operation with 4 preset speeds and 2 logic inputs

b Jog operation This can be used for pulse operation with minimum ramp times (0.1 s), limited speed reference and minimum time between 2 pulses. It is enabled by 1 logic input and pulses given by the operating direction command. Function suitable for machines with product insertion in manual mode (e.g. gradual movement of the mechanism during maintenance operations).

f (Hz)

t JGt Forward or Reverse

1 0 1
t

JOG 0 Speed reference: can be set from 0 to 10 Hz, factory setting 10 Hz.

t JGt: minimum time between 2 pulses, which can be set between 0.5 and 2 s.

Example of jog operation

b Limiting low speed operating time The motor is stopped automatically after a period of operation at low speed (LSP) with a zero reference and a run command present. This time can be set between 0.1 and 999.9 seconds (0 corresponds to an unlimited time). Factory setting 0 s. The motor restarts automatically on the ramp when the reference reappears or if the run command is interrupted and then re-established. Function suitable for automatic Stops/Starts.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

156

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

b Motor control types v Flux vector control with sensor (FVC) This control type can be used to obtain the best static and dynamic torque performance. v Sensorless flux vector control In voltage mode, this control type can be used with a single motor or motors connected in parallel. In current mode, this profile performs better than the previous type, but it cannot supply power to motors connected in parallel. v 2-point vector control The zone for operating at constant power can be optimized by defining an additional point in the control profile. This function should be used with motors offering a two-part defluxing zone. It can be used to limit the voltage at the motor terminals when the motor is being powered by a high line supply. v Voltage/frequency ratio This control type is particularly suitable for special motors (high-speed motors, synchronized asynchronous motors, etc.). The ratio can be adjusted by 2 or 5 points and used to achieve output frequencies of up to 1000 Hz. v ENA system This profile is reserved for unbalanced machines (presses, etc.). It can be used to reduce mechanical stress, power consumption and avoid the use of braking resistors. v Synchronous motor This control type is exclusively reserved for controlling open loop synchronous permanent magnet motors with sinusoidal electromotive force (EMF).

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

157

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

b Using an incremental encoder The Altivar 71 drive uses encoder feedback to: v Operate in FVC closed loop control mode. In addition to the torque performance and speed accuracy it provides, the speed feedback can also be used to manage overspeed and slipping protection. v Improve the steady state speed accuracy and/or manage overspeed and slipping protection in the other control types (FVC open loop control mode and U/f ratio) v Manage only overspeed and slipping protection b Encoder tests The Altivar 71 drive can detect encoder signal loss, as well as a mechanical break in the coupling between encoder and motor. b Limiting motor overvoltage The Altivar 71 drive inverter bridge control can be used to limit overvoltage in the motor terminals, which is double the voltage level in the DC bus (Stressless PWM). This function is useful in cases where long lengths of cabling, rewound motors or motors in a low isolation class are involved. b Auto-tuning Auto-tuning can be performed: v using a dialogue tool (graphical display terminal, PowerSuite software workshop, integrated 7-segment display terminal) v via a communication network v automatically every time the drive is switched on v by enabling a logic input Auto-tuning can be used to enhance application performance. In Flux Vector Control mode (FVC closed loop and FVC open loop with current control), certain parameters are measured periodically. Saving the motor thermal state can help to compensate exactly for the motor resistors, even after the drive has been switched off. b Switching frequency, noise reduction By controlling the switching frequency, it is possible to reduce the noise generated by the motor for any application requiring a low level of noise. The switching frequency is modulated randomly in order to avoid resonance. This function can be disabled if it causes instability. High frequency switching of the intermediate DC voltage can be used to supply the motor with a current wave that has a lower harmonic distortion. The switching frequency can be adjusted during operation to reduce the noise generated by the motor. Value: 1 to 16 kHz; factory setting 2.5 or 4 kHz, depending on the rating.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

158

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

b Motor fluxing This can be used to obtain rapid high torque on start-up; magnetic flux needs to be already established in the motor. There is a choice between open loop or closed loop operation. In continuous mode, the drive automatically establishes the flux when it is powered up. In non-continuous mode: v If a logic input or command word bit is assigned to the motor fluxing command, flux is established when the command is confirmed. v If an input logic or command word bit has not been assigned, or if the latter are not active when a run command is given, fluxing occurs when the motor starts. Fluxing is accelerated if a higher current than the nominal motor current is applied, then it is set to the value of the motor no-load current.
Frequency Reference bIr jdC jdC bEn Flux current Nominal flux current Torque current Ibr 0 reached t Direction of operation. Ascending Descending t Relay or logic output Fluxed motor t

b Brake control This can be used to manage control of an electromagnetic brake in synchronization with starting and stopping the motor to avoid jolts and load slipping. The brake control sequence is managed by the drive.
t

v Movement type The Altivar 71 drive adapts the brake control operation to the type of movement, whether vertical or horizontal, in order to achieve maximum torque performance and eliminate jolts. v Brake feedback via contact By connecting a brake contact to the drive, it is possible to detect brake faults. If the brake status does not match the relevant control (the contact must be open for a released brake), the drive locks when a fault occurs. v Brake release pulse This can be used to set the torque for brake release when ascending (forward) or two release thresholds (one for ascending and the other for descending). This function is only available for vertical movements.

0
Brake contact

t Brake status Released Engaged brt tbE bEt ttr t

v Brake engage on reversal of operating direction To prevent the speed from passing through zero when reversing the direction of rotation, the drive firstly requires the brake to be engaged at the end of deceleration and then for it to be released before accelerating in the other direction of rotation. v Brake engage request time delay In the case of slewing movements, this function can be used, at the end of deceleration, to control how the brake is engaged when the torsional stress being exerted on the machine structure is zero. v Automatic DC injection In the case of a horizontal movement, the DC injection at the end of deceleration can be used to prevent jolting when the brake is being engaged. This function is only available for horizontal movements.

Open loop vertical movement


bEn: Brake engage frequency bEt: Brake engage time bIr: Initialization of ramp once the brake release time (brt) has expired brt: Brake release time Ibr: Brake release current JdC: Reverse jump tbE: Brake engage time ttr: Restart time

Note: in open loop mode, feedback from an incremental


encoder can be connected to the drive in order to directly detect overspeed and slipping.

b Limit switch management This can be used to manage the operation of one or two limit switches (non-reversing or reversing). Each limit (forward, reverse) is associated with a logic input. The type of stop that occurs on detection of a limit can be configured as a stop on ramp, freewheel or fast stop. Following a stop, the motor is permitted to restart in the opposite direction only.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

159

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

b High-speed hoisting This can be used to optimize cycle times for hoisting movements when the load is zero or small. It allows operation at constant power (motor defluxing beyond the nominal motor frequency) in order to achieve a higher speed than the nominal speed, without exceeding the nominal motor current and thereby preventing the motor from overheating. There are 2 possible operating modes: v Speed reference mode: The maximum permitted speed is calculated by the drive at an imposed speed step so that the drive can measure the load.
Command Ascending or Descending

0
Reference HSP

FrS OSP

0
Frequency HSP Calculated limit FrS OSP

t
tOS

Speed reference mode


FrS: Nominal motor frequency HSP: High speed parameter OSP: Adjustable speed step for load measurement tOS: Load measuring time Two parameters can be used to reduce the speed calculated by the drive, for ascending and descending.

v Current limiting mode: The maximum permitted speed is the speed at which the current is limited in the motor quadrant, ascending only. For descending, operation is always based on speed reference mode.
Command Ascending

0 Reference HSP
FrS SCL

0 Frequency HSP
FrS SCL

Limit imposed by current limitation

0
Current CLO

Current limiting mode


CLO: Current limitation for high speed-function FrS: Nominal motor frequency HSP: High speed parameter SCL: Adjustable speed threshold above which current limitation is active

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

160

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

lbr Point 2Y (CP2)

b External weight measurement This function uses the information supplied by a weight sensor via an analog input (usually a 4-20 mA signal) to adapt the current (lbr) of the Brake logic control function.
Point 1X (LP1) Weight sensor signal Point 2X 100 % (LP2) Zero load

Function suitable for applications involved in: v measuring the total weight of a hoisting winch and its load v measuring the total weight of a lift winch, the cabin and counterweight. The current (lbr) is adapted according to the curve opposite.

Point 1Y (CP1)

CP1, CP2, LP1, LP2: weight sensor calibration points

This curve can represent a weight sensor on a lift winch, where a zero load is exerted on the motor when the load in the cabin is not zero.
C Tn

LbC

b Load sharing This function can be used for applications where several motors are mechanically linked in order to share the loads of the different motors by adjusting the speed according to the torque on each motor. b Control and integrity check of output contactor
F

v Control This allows the drive to control a contactor located between the drive and the motor. The request to close the contactor is made when a run command appears. The request to open the contactor is made when there is no current in the motor. Note: If a DC injection braking function has been configured it should not be left operating too
long in stop mode, as the contactor only opens at the end of braking.

Tn LbC: Load correction (Hz)

LbC

Load sharing

ATV 71

Command

Feedback

+ 24 V

v Integrity check This check is carried out by connecting a volt-free contact on each contactor to one of the drives logic inputs. The corresponding logic input should be at 1 when there is no run command and at 0 during operation. When there is any inconsistency, the drive locks in fault mode if the output contactor does not close (LIx = 1) or gets stuck (LIx = 0). The time delay for when the drive locks in fault mode can be adjusted. These sequences are commonly used in lift applications. In order to enhance the level of security and reduce the amount of maintenance work, it is recommended that the Altivar 71 drives integrated Power Removal safety function is used. b Stop on thermal alarm This can be used to: v Allow a movement to end before examining a thermal fault. There are two adjustable thresholds used to define the thermal state level which, when exceeded, makes a machine stop; v Prevent a new run command from being accepted as long as the drive and motor temperatures are not less than 100%. Function suitable for lift applications: it can prevent people getting trapped if a lift gets stuck between two floors. b Evacuation following power failure This can be used to control the reduced speed engine with a reduced voltage supply (220 V z, for example: uninterruptible power supply (UPS)), by preserving torque performance. Function suitable for lift applications: When there is a power failure, it facilitates the evacuation of people trapped in a lift stuck between two floors.

LO/Rp

K20 KM2

LIp KM2

0
K20

M 3

KM2

Control and integrity check of output contactor

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

161

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

b Uncontrolled output cut It is possible to configure output phase loss protection, which will allow the drive or motor circuit to be broken without the drive becoming locked in fault mode and facilitate a smooth restart after the motor has been reconnected. The output phase loss may also lock the drive, depending on the configuration.
RDY Term +0.00Hz 0.0A
LI3 LI4 RAM

+/- SPEED

+ speed assign. : - speed assign. : Ref. saved :

b +/- speed This can be used to increase or decrease a speed reference by means of 1 or 2 logic inputs, with or without the last reference being saved (motorized potentiometer function). This function is suitable for centralized control of a machine with several sections operating in one direction or for control by a handling crane pendant control station with two operating directions. Two types of operation are available: v Use of single action buttons: 2 logic inputs are required in addition to the operating direction(s). v Use of double action buttons: only 1 logic input assigned to + speed is required. Use of single action buttons: 2 logic inputs are required in addition to the operating direction(s).
f (Hz) HSP

522166

Code
+/- speed function settings

Quick

LSP Forward 1 or Reverse 0


1

+ speed 0
1

- speed 0 LSP: low speed, HSP: high speed

Example of "+/- speed" with 2 logic inputs, single action buttons and reference saving

Use of double action buttons: only 1 logic input assigned to + speed is required. Logic inputs:
Forward Reverse + speed

a and b: 1st press c and d: 2nd press f (Hz) HSP LSP 0 LSP

Forward button Reverse button

Released 1st press (- speed) (speed maintained) a c

2nd press (+ speed) a and b c and d

t HSP Forward 2nd press 1st press 0 Reverse operation 2nd press 1st press 0 LSP: low speed, HSP: high speed

b b a a a a

d c

Example with double action buttons and 1 logic input Note: This type of +/- speed control is incompatible with 3-wire control.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

162

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

v Reference saving This function is associated with +/- speed control. This can be used for reading and saving the last speed reference prior to the loss of the run command or line supply. The reference saved is applied the next time a run command is received.
Motor frequency

+ SRP %
Reference SRP %

LSP LSP SRP % Reference + SRP %


+ speed speed Direction of operation

v +/- speed around a reference The reference is given by Fr1 or Fr1b, including, if relevant, the summing, subtraction and multiplication functions, as well as the preset speeds. During the run command the drive goes to the reference, following the acceleration and deceleration ramps (pressing +/- speed makes the speed vary around this reference according to acceleration ramp 2 and deceleration ramp 2). + or - speed variation around the reference is limited to a percentage of the reference (SRP parameter). When operation has stopped, the amended reference is not saved. The maximum total reference is always limited by high speed (HSP parameter) and the minimum reference (LSP parameter).
Forward Reverse Forward

Example of +/- speed around a 2-wire control reference

b Spooling v Traverse control Function for winding reels of thread (in textile applications)
Spooling drive Winding drive

Reel of thread Gearbox Motor Main shaft

Thread guide Gearbox Thread guide motor Cam

Thread

The cam rotation speed must follow a precise profile to ensure a steady, compact, linear reel is obtained.
Run command t Traverse Control LI or command bit t Motor speed Base reference Start of function End of function Ramp dEC t

Ramp ACC

Bit 15 of the LRS1 word (Traverse Control in progress)

A function can also be used to reduce the base reference as the reel gets larger.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

163

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

v Counter Wobble
Traverse Control master drive Counter Wobble slave drive

CLO

SnC

Synchronization Gearbox Winding motor

Reel of thread Main shaft

Thread guide Gearbox Thread guide motor


Cam

The Counter Wobble function is used in certain applications to obtain a constant thread tension when the Traverse Control function is producing considerable variations in speed on the thread guide motor. The master drive controls the speed of the thread guide, while the slave drive controls the winding speed. The function assigns the slave a speed profile which is in antiphase to the masters. This means that synchronization is required, using one of the masters logic outputs and one of the slaves logic inputs.
Run command on master and slave t Traverse Control command on master and slave Thread guide motor speed (master drive)

t trH trL

t SnCl/SnCO synchronization t Winding motor speed (slave drive) trH trL

b Automatic catching of a spinning load with speed detection (catch on the fly) This function can be used to restart the motor smoothly after one of the following events, provided the run command is still present: v loss of line supply or power off v fault reset or automatic restart v freewheel stop. Once the event is over, the effective speed of the motor is detected in order to restart on a ramp at this speed and return to the reference speed. The speed detection time can reach 0.5 s. This function is automatically disabled if the brake sequence is configured. It is suitable for machines which suffer low motor speed loss during a power failure (high-inertia machines such as centrifuges, etc.).

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

164

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

b Undervoltage management Depending on the application, it is possible to configure the Altivar 71s response to undervoltages or power failures. If undervoltage occurs: v The Altivar 71 drive can continue operating with undervoltage levels up to -50% (adjustable threshold) v If the drive locks as a result, management of the fault relay can be configured (open or not). If the fault relay does not open an alarm is shown. The Altivar 71 drive can also be configured to prevent the drive locking (using an alarm): v Controlled stop according to the type of stop configured v Deceleration based on a ramp which it automatically adapts to maintain the DC bus voltage, thereby preventing the drive from locking in fault mode v Instant IGBT (inverter bridge) loss followed by power supplied to the motor as soon as the line voltage has reappeared. This function can be used to prevent the Altivar 71 drive being reinitialized. b Braking balance When several drives are connected on a common DC bus, this function can be used to adjust the braking thresholds in order to balance the braking powers among the various drives or braking units. b Braking resistor thermal protection The Altivar 71 drive incorporates thermal protection for braking resistors if it is not fitted with a thermal switch. If the resistor thermal state is too high an alarm can be assigned to the logic output or the drive may lock in fault mode, depending on how the function is programmed. b Parameter set switching (multi-parameter) This can be used to switch 3 sets of 15 parameters maximum when the motor is running. Each set can contain a different value for each of the parameters. The sets are switched using 1 or 2 logic inputs or command word bits. Function suitable for machines involving 2 or 3 manufacturing processes. b Motor or configuration switching (multi-motor or multi-configuration)
Configuration 0 if the two switches are open. Configuration 1

ATV 71
LO or R

LIx

Configuration 0 LO or R

+ 24 V Configuration 1
Configuration 2

LIy

LO or R Configuration 2

The Altivar 71 drive can have 3 configurations, which can be activated remotely, allowing it to adapt to: v 2 or 3 different motors or mechanisms in multi-motor mode. In this instance, the thermal state for all the motors is calculated and saved. This means that each motor is protected thermally. v 2 or 3 configurations for the same motor in multi-configuration mode. This function can also be used to save the current configuration in another memory zone, which it can be retrieved from. Switching is carried out using 1 or 2 logic inputs, depending on the number of motors or configurations chosen (2 or 3). Multi-motor and multi-configuration modes cannot be used together.

M0

M1

M2

Schematic diagram for multi-motor mode

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

165

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

b Positioning on limit switches or position sensors This can be used to manage positioning based on limit switches or position sensors.
Forward

0 Reverse
Reverse stop Reverse slowdown Reverse Forward Forward slowdown Forward stop

0 FWD slowdown 0 FWD stop limit 0 speed


Min. speed (LSP) 0

Example 1: limit switch positioning


Slowdown and stopping occur when the sensor is changing state (open contact). It is possible to assign a command word bit or a logic input to disable the function in order to be able restart or not stop on the position.

Activating the slowdown contact or stop contact allows the device to start in the other direction, even at high speed. Slowdown mode can be configured: v The drive uses the validated ramp time v The drive calculates a ramp time according to the actual speed when the request to slow down is made. This calculation can be used to optimize the cycle time by limiting the time spent operating at low speed. The stop type can also be configured: v stop on ramp v freewheel stop v fast stop b Short and long cam operation v Short cams In this instance, when operating for the first time or after restoring the factory settings, the drive must initially be started outside the slowdown and stop zones in order to initialize the function.
Forward slowdown zone

Revers e

Forward low speed

Reverse low speed

Forward Trajectory

Reverse slowdown

Reverse stop

Example 2: positioning on a target zone


The disable contact can be used to restart in order to get past the target.

Forward slowdown

Forward stop

Forward slowdown

Forward stop zone

Forward stop

v Long cams In this instance, there is no restriction, which means that the function is initialized across the whole trajectory.
Forward slowdown zone

Forward slowdown

Forward stop zone

Forward stop

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

166

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

f (Hz) Fr1b

Fr1
t Forward or 1 Reverse 0

b Reference switching Switching between two references (speed, torque, PID, etc.) can be enabled by: v a logic input v a command word bit Reference 1 (Fr1) is active if the logic input (or command word bit) is at 0; reference 2 (Fr1b) is active if the logic input (or command word bit) is at 1. References can be switched with the motor running. Reference Fr1b, like Fr1, can originate from: v an analog input (AI) v a frequency control input (RP) v the graphic display terminal v the Modbus or CANopen bus v a communication card v the Controller Inside programmable card b Operations on references (summing, subtraction, multiplication) Summing, subtraction and multiplication inputs can be activated simultaneously.

1 LIx 0
t

Example of reference switching

Fr1 or Fr1b

SA2 SA3 dA2 dA3 MA2 MA3 A

The drive reference is thus: v reference of drive A = (Fr1 or Fr1b + SA2 + SA3 - dA2 - dA3) x MA2 x MA3 v Summing inputs They can be used to add 2 to 3 references from different sources to Fr1 or Fr1b (see Reference switching). The references to be added together are selected from all the possible types of reference. For example, Reference Fr1 or Fr1b from AI1 Reference SA2 from CANopen Reference SA3 from a communication card Reference of drive A = Fr1 or Fr1b + SA2 + SA3. v Subtraction inputs They can be used to subtract 2 to 3 references from different sources from Fr1 or Fr1b (see Reference switching). The references to be subtracted are selected from all the possible types of reference. For example, Reference Fr1 or Fr1b from AI1 Reference dA2 from CANopen Reference dA3 from a communication card Reference of drive A = Fr1 or Fr1b - dA2 - dA3. v Multiplication inputs They can be used to multiply 2 to 3 references from different sources by Fr1 or Fr1b (see Reference switching). The references to be multiplied are selected from all the possible types of reference. For example, Reference Fr1 or Fr1b from AI1 Reference MA2 from CANopen Reference MA3 from a communication card Reference of drive A = Fr1 or Fr1b x MA2 x MA3.

A: drive reference SA2, SA3: summed inputs dA2, dA3: subtraction inputs MA2, MA3: multiplication inputs.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

167

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

b PID regulator This can be used to regulate a process with a reference and feedback given by a sensor. Function suitable for controlling traction on a winder.
LI PII nO rPI A rP2 rP3 rP4 Preset PID references PrP Pr2 Pr4

Ramp

Restart error threshold Error inversion (wake-up) Gains PIC tLS

Auto/Man.
PAU POH rIG

rdG rPG

+ +
B

POL

Internal references

Scaling
PIF nO AI1 ... AI4 RP Encoder Network AI PIF1 / PIF2 PIP1 / PIP2

Predictive speed reference FP1

Ramps
ACC DEC x PSr

nO PIM Manual reference SP2 ... SP16 ...

(man.) Preset manual references

PID

ACC: Acceleration, DEC: Deceleration, LI: Logic inputs, B: Speed reference.

v Internal references - rPI: reference transmitted by the graphic display terminal or a communication network. - A: reference given by Fr1 or Fr1b with the summing, subtraction and multiplication functions, as appropriate. The PII parameter is used to choose between these two references. v Preset PID references 2 or 4 PID references are available. Table showing combinations of selected PID references:
LIx (Pr4) 0 0 1 1 LIy (Pr2) 0 1 0 1 Reference rPI or A rP2 rP3 rP4

v PID feedback PID feedback can be assigned to one of the analog inputs (AI1 to AI4), the frequency control input (RP) or the encoder, depending on the option cards present. It can also be transmitted by a communication network (AI network). v Predictive speed reference This reference can come from the terminals (analog inputs, encoders, etc.), the graphic display terminal or a communication network. This speed input gives an initial reference for starting. v Auto/Man. This can be used to switch from speed regulation mode (Man.) to PID regulation mode (Auto). A logic input or command word bit is used for switching. Speed regulation mode (Man.) The manual reference is transmitted via the terminals (analog inputs, encoder, preset speeds, etc.). With manual switching, the speed reference changes according to the ramp times ACC and DEC. PID regulation mode (Auto) In automatic mode it is possible to: - adapt the references and feedback to the process (transformation) - correct a PID inversion - adjust the proportional, integral and derivative gains (Kp, Ki and Kd) - shunt the integral - use the alarm on the logic output or display it on the graphic display terminal, if the threshold is exceeded (Max. feedback, Min. feedback and PID error) - display the PID reference, PID feedback, PID error and PID output on the graphic display terminal and assign them to an analog output - apply a ramp (time = PrP) to the PID reference. The motor speed is limited to between LSP and HSP. It is displayed as process values.
Presentation: pages 6 to 9 Characteristics: pages 10 to 15 Catalog numbers: pages 20 and 21 Dimensions: pages 92 to 113 Wiring diagrams: pages 114 to 129

168

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

b Torque control This supports torque control or speed regulation mode. These two types of mode can be switched using a logic input or command word bit. Function suitable for applications requiring traction control.
Speed reference Torque reference Speed Speed regulation Torque Torque / current limit M

Torque ref. sign (tSd)

Torque ratio (trt)

Torque ramp (trP)

Switching command

The torque reference is signed and has its own ramp. A torque ratio can be used to scale the reference. It can be transmitted via an analog input, frequency control input (RP input or encoder) or communication network. The torque sign and value can be output to a logic output and an analog output. In torque control mode the speed may vary within an adjustable dead band. When it has reached the lower or upper limit, the drive automatically switches to speed regulation mode (fallback position). The regulated torque is no longer maintained, in which case two scenarios can occur: v The speed falls within the dead band; the torque takes the required value. v The torque does not return to the required value at the end of an adjustable time; the drive switches to fault or alarm mode, depending on the configuration.
Torque Torque limit

Torque reference

Speed dead band

D
Speed reference Speed

AB and CD: Fallback position BC: Torque control zone E: Ideal operating point

The stop in torque control mode can be configured: v automatic switch to speed regulation mode v freewheel stop v stop at zero torque but still maintaining the flux in the motor for an adjustable period of time.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

169

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

b Torque limit This can be used to limit the torque in the motor and generator quadrants using separate settings. There are two types of torque limit: v one with a value set by a parameter v the other with a value given by an analog input, frequency control input or encoder. When both torque limit types are enabled it is the lowest value which is read. They can be switched using a logic input or command word bit. This function is not available for voltage/frequency ratio. Torque +
150 % 100 %

Speed Reverse operation

Generator mode Reverse speed torque + Motor mode Reverse speed torque

Motor mode Forward speed + torque + Generator mode Forward speed + torque

Speed + Forward

100 % 150 %
Torque

Overload range Motor torque Torque limit

The torque limit operates in both directions of rotation in motor or generator mode.

b Torque or current limit detection This function can be used to detect when the current or torque limit has been reached. Depending on the configuration, it is possible to: v use an alarm to signal this v lock the drive after an adjustable period of time.
RDY Term
: :

+0.00Hz

0.0A
LI6 6.4 A 7.9 A

2nd CURRENT LIMIT. I Limit. 2 activ. I Limit. 2 value

Current limitation :

b Current limit A 2nd current limit can be configured between 0 and 1.65 times the drive nominal current and it can be used to limit the rise in motor temperature and the torque. Switching between 2 current limits can be enabled via: v a logic input v a command word bit

522170

Code

Quick

Configuring current switching

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

170

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

F: motor frequency

0
Run command 1

0
LIx (saved) 1

b Reference saving This can be used to: v Read and save the speed reference value of the analog input using a logic input when the command lasts longer than 0.1 s v Control the speed of several drives alternately via a single analog reference and a logic input for each drive v Enable via a logic input a line reference (serial link) on several drives in order to synchronize movements by eliminating variations when the reference is sent The reference is acquired 100 ms after the rising edge of the request. A new reference is not then acquired until a new request is made.

0 100 ms 100 ms 100 ms

Analog reference

Example of how reference saving works

RDY

Term
:

+0.00Hz

0.0A

STOP CONFIGURATION Type of stop Ramp stop NO LI4 0 NO Freewheel assign. : Fast stop assign. : Ramp divider : DC inject. assign. :

b Stop types v Freewheel stop This can be used to stop the motor by resistive torque only if the supply to the motor is removed. A freewheel stop is achieved: - by configuring a normal stop command as a freewheel stop (when a run command is over or a stop command occurs) - by enabling a logic input - by activating a command word bit v Fast stop This can be used to achieve a braked stop with an acceptable deceleration ramp time (divided by an adjustable coefficient from 0 to 10) for the drive/motor unit to avoid locking in the event of an overbraking fault. If the coefficient is equal to 0 the motor decelerates as fast as possible. This is used for conveyors with emergency stop electrical braking. A fast stop is achieved: - by configuring a normal stop as a fast stop (when a run command is over or a stop command occurs) - by enabling a logic input - by activating a command word bit v Fastest possible stop If the ramp divider coefficient is equal to 0 the motor decelerates as fast as possible. v DC injection stop This can be used to brake high-inertia machines at low speed or maintain torque on stopping. A DC injection stop is achieved: - by configuring a normal stop as a DC injection stop (when a run command is over or a stop command occurs) - by enabling a logic input - by activating a command word bit The DC value and the standstill braking time are adjustable.

522142

Code
Configuring stop types

Quick

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

171

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

b Motor thermal protection Motor thermal protection is provided by the drive: v directly, through PTC probes located in the motor windings v indirectly, via the integrated thermal relay. Indirect thermal protection is implemented via continuous calculation of its theoretical temperature rise. The microprocessor calculates the theoretical temperature rise of the motor based on various elements: v the operating frequency v the current taken by the motor v the operating time v the maximum ambient temperature around the motor (40C) v the type of motor ventilation (self-cooled or force-cooled) Thermal protection can be adjusted from 0.2 to 1.5 times the nominal drive current. It must be adjusted to the nominal current indicated on the motor rating plate. Note: The motor thermal state memory returns to zero when the drive control part is switched
off.
t

10 000 (a 2 h 45)

13 5

10

20

50 Hz

Trip time in seconds

1 000 (a 16 min)

100 0,7 0,8 0,9 1 1,1 1,2 1,3 1,4 1,5 1,6 Motor current/ItH

Motor thermal protection curves

v Self-cooled motors: The tripping curves vary with the motor frequency. v Force-cooled motors: Only the 50 Hz tripping curve should be considered, whatever the motor frequency. b Drive thermal protection The drives thermal protection is provided by a PTC probe fitted on the heatsink or integrated with the power module. b IGBT thermal protection The drive manages the switching frequency intelligently according to the IGBT temperature. If the drives current rating is exceeded (e.g. current higher than the nominal drive current for a zero stator frequency), an alarm is displayed and a timer increases for as long the alarm is present.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

172

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

RDY

Term

+0.00Hz

0.0A

4-20mA LOSS Fallback spd Spd maintain Ramp stop Fast stop DC injection

Quick
Configuration of the drives fault response

b Configuring the drives fault response (fault management) Different responses can be configured for the drive in the event of a resettable fault occurring: v freewheel stop v drive switches to the fallback speed v drive maintains the speed at which it was operating when the fault occurred until the fault disappears v stop on ramp v fast stop v DC injection stop v no stop (alarm activated) List of resettable faults: v external fault v speed feedback loss v overspeed v slipping v output phase loss v auto-tuning fault v brake contactor feedback fault v encoder coupling v loss of 4-20mA v PTC probe v drive overheating v motor overload if the thermal state is less than 100% v line overvoltage v overbraking v current/torque limit v IGBT overheating v communication faults (Modbus, CANopen and other communication networks) b Resetting resettable faults This can be used to remove the last fault using a logic input, command word bit or the STOP/RESET key on the graphic display terminal. The restart conditions after a reset to zero are the same as those of a normal power-up. List of resettable faults, see Configuring the drives fault response. Line supply undervoltage and input phase loss faults are reset automatically when the line supply is restored. Function suitable for applications where drives are difficult to access, for example, a drive placed on a moving part. b General reset (disables all faults) This function can be used to disable all faults, including thermal protection (forced operation) and may cause irreparable damage to the drive. Function suitable for applications where restarting may be crucial (conveyor in an oven, smoke extraction system, machines with solidifying products to be discarded). The function is enabled by a logic input. Fault monitoring is active if the logic input is at state 1. All faults are reset on a change of state of the logic input. Note: Use of this function invalidates the guarantee.

522143

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

173

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

b Automatic restart This enables the drive to be restarted automatically after it has locked in fault mode if the relevant fault has disappeared and the other operating conditions permit a restart. This restart is performed by a series of automatic attempts separated by increasingly longer waiting periods of 1 s, 5 s, 10 s then 1 minute for the rest. The options for the restart processs duration are 5, 10 and 30 min., 1, 2, 3 hours and an unlimited time. If the drive has not restarted after the configured time, it will lock and the procedure is abandoned until it has been switched off and on again. The faults which allow the drive to be restarted in this way are: v line overvoltage v motor thermal overload v drive thermal overload v DC bus overvoltage v line phase failure v external fault v loss of 4-20mA v PTC probe v serial link v current or torque limit v output phase loss v line voltage too low. For this fault, the function is always active, even if it is not configured. v fault caused by CANopen, Modbus or other commmunication networks. These faults are reset automatically as soon as the command word or frequency reference is sent to the drive. For these types of fault, the relay configured as a fault relay remains activated if the function is configured. The speed reference and operating direction must be maintained for this function. This function is suitable for machines or installations which are in continuous operation or unmonitored, and where a restart will not endanger equipment or personnel in any way. b PTC probe protection The probes can be connected directly to the drives control card or to the I/O option cards. The way in which a temperature fault is recorded by the drive can be configured: v permanent record v only recorded when the drives power section is switched on v only recorded when the motor is running b IGBT testing When enabled, this function tests every IGBT and the motor connections in order to detect a short-circuit or an open circuit. This test is run every time the drive is powered on and before each motor start. This function must not be enabled with machines with fast cycles in order to preserve the time for recording run commands. b Resetting operating time to zero The drives operating and power-up time can be reset. b External fault This function can lead to the drive locking if a fault occurs in the machine. This fault is flagged on the drive display unit. The fault is flagged if the signal is at 1 or 0, according to the functions configuration.

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

Wiring diagrams: pages 114 to 129

174

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Variable speed drives for asynchronous motors


Altivar 71

b Line contactor control This can be used on each run command to close the line contactor and open it when the motor is no longer on. The drives control section must be powered without fail by an external 24 V c source. This function must be used for simple sequences with a low number of Start/Stop operations (Start/Stop cycle longer than 60 seconds).
Emergency stop Line 3 a Run

K10 KM1 K11

L1

L2

L3

Forward or reverse

K11 K10

M 3

External source 24 V c

After a run command, if the line contactor is not closed the drive will lock after an adjustable period of time. b Forced local mode Forced local mode imposes control via the terminals or graphic display terminal and disables all other control modes. Switching to forced local mode may be activated via: v a logic input v a function key on the graphic display terminal The following references and commands are available for forced local mode: v references AI1, AI2, etc. and command via logic inputs v reference and command via the graphic display terminal

Presentation: pages 6 to 9

Characteristics: pages 10 to 15

Catalog numbers: pages 20 and 21

Dimensions: pages 92 to 113

24 V

0V

LO/R

ATV 71
P24 LIn LI

Wiring diagrams: pages 114 to 129

Global Catalog. Refer to Statement of Scope on page 2.

175

Functions

Variable speed drives for asynchronous motors


Altivar 71

Function compatibility table


b Configurable I/O Functions which are not listed in this table are fully compatible. Stop functions have priority over run commands. The selection of functions is limited: v By the number of drive I/O which can be reassigned: if necessary, add an I/O extension card. v By the incompatibility of certain functions with one another. Functions
Operation on the references +/- speed (3) Limit switch management Preset speeds PID regulator Traverse control Jog operation Brake control

Operation on the references

+/- speed (3)

Limit switch management Preset speeds

PID regulator

Traverse control

Jog operation

Brake control

Automatic catching a spinning load with speed detection (catch on the fly) Control and integrity check of output contactor DC injection stop

Fast stop

Freewheel stop

+/- speed around a reference

High-speed hoisting

Torque control (1) Load sharing (1) (1) (1) (1) (1) (1)

Position control via limit switches (1) Torque control and the speed reference functions are only incompatible if torque control mode is active. (2) Priority is given to the first of these two stop modes to be activated. (3) Excluding special use with reference channel Fr2. Incompatible functions Compatible functions N/A Priority functions (functions which cannot be active at the same time) The arrow indicates which function has priority. X

Example: The "Freewheel stop" function has priority over the "Fast stop" function.

176

Global Catalog. Refer to Statement of Scope on page 2.

Automatic catching a spinning load with speed detection (catch on the fly)

Control and integrity check of output contactor

DC injection stop

Fast stop

Freewheel stop

+/- speed around a reference

High-speed hoisting

Torque control

Load sharing Position control via limit switches

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(2)

A A

(2)

X
(1)

(1)

(1)

(1)

(1)

Global Catalog. Refer to Statement of Scope on page 2.

177

Presentation, functions

PowerSuite software workshop

533180

Presentation
The PowerSuite software workshop is a user-friendly tool designed for setting up control devices for the following Telemecanique brand motors: b TeSys model U controller-starters b Altistart soft start/soft stop units b Altivar variable speed drives It includes various functions designed for setup phases such as: b Preparing configurations b Start-up b Maintenance In order to simplify the start-up and maintenance phases, the PowerSuite software workshop can use the Bluetooth wireless link.

PowerSuite software workshop for PC


Functions (1) Preparing configurations The PowerSuite software workshop can be used on its own to generate the device configuration. It can be: b Saved, printed and exported to office automation software The PowerSuite software workshop can also be used to convert: b An Altivar 28 drive configuration to an Altivar 31 drive configuration b An Altivar 58 or Altivar 58F drive configuration to an Altivar 71 drive configuration Setup When the PC is connected to the device, the PowerSuite software workshop can be used to: b Transfer the generated configuration b Adjust b Monitor: This option has been enhanced with new functions such as: v The oscilloscope v The high speed oscilloscope (minimum time base: 2 ms) v Display of communication parameters b Control b Save the final configuration Maintenance In order to simplify maintenance operations, the PowerSuite software workshop can be used to: b Compare the configuration of a device currently being used with a saved configuration b Manage the users installed base of equipment, in particular: v Organize the installed base into folders (electrical equipment, machinery, workshops, etc) v Store maintenance messages v Simplify Ethernet connection by storing the IP address User interface The PowerSuite software workshop can be used to: b Present the device parameters arranged by function in the form of illustrated views of diagrams or simple tables b Customize the parameter names b Create: v A user menu (choice of particular parameters) v Monitoring control panels with graphic elements (cursor, gauges) b Perform sort operations on the parameters b Display text in five languages (English, French, German, Italian and Spanish). The language changes immediately and there is no need to restart the program. It also has online contextual help: b On the PowerSuite tool b On the device functions by direct access to the users manuals.
(1) Some functions are not available for all devices. See the table of function availability, page 179.

PowerSuite screen on PC Management of the installed base

533181

PowerSuite screen on PC View of PI regulator function parameters

533182

PowerSuite screen on PC Monitoring control panel (cursor, gauge)

Catalog numbers: page 181

178

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

PowerSuite software workshop

Availability of functions for the PowerSuite software workshop for PC Functions not listed in the table are available for all devices.
Function available with devices Controllerstarter TeSys model U Monitoring Oscilloscope High speed oscilloscope Display of communication parameters Control Customization of parameter names Creation of a user menu Creation of monitoring control panels Sort operation on parameters Functions available Functions not available Soft start/ soft stop unit ATS 48 Drives

ATV 11

ATV 31

ATV 58 ATV 71 ATV 58F

PowerSuite

Connections Modbus communication bus The PowerSuite software workshop for PC can be connected directly to the device terminal port or Modbus network port via the serial port on the PC. Two types of connection are possible: b With a single device (point-to-point connection) b With a number of devices (multidrop connection) Ethernet TCP/IP communication network The PowerSuite software workshop for PC can be connected to an Ethernet network (see pages 182 to 187). In this case, the devices can be accessed: b Using a 174 CEV 300 20 Ethernet-Modbus bridge b Using a VW A3 310 communication card for the Altivar 71 drive b Using a VW3 A58 310 communication card for the Altivar 58 and 58F drives Bluetooth wireless link (2) The PowerSuite software workshop for PC can communicate via a Bluetooth radio link with a device equipped with a Bluetooth - Modbus VW3 A8 114 adaptor. The adaptor plugs into the device terminal port or Modbus network port, and has a range of 10 m (class 2). If the PC does not have Bluetooth technology, use the VW3 A8 115 USB-Bluetooth adaptor. Remote maintenance Using a simple Ethernet connection, the PowerSuite software workshop can be used for remote monitoring and diagnostics. When devices are not connected to the Ethernet network, or it is not directly accessible, various remote transmission solutions may be possible (modem, teleprocessing gateway, etc). Please consult your Regional Sales Office. Hardware and software environments The PowerSuite software workshop for PC can operate in the following PC environments and configurations: b Microsoft Windows 98 SE, Microsoft Windows 2000, Microsoft Windows XP b Pentium III, 800 MHz, hard disk with 300 Mb available, 128 Mb RAM b SVGA or higher definition monitor
(1) Please consult our specialist Automation platform Modicon Premium and Unity - PL7 software and Automation platform Modicon TSX Micro - PL7 software catalogues. (2) Not available for Altivar 11 and Altivar 68 drives.

533183

RS 232 XGS Z24 RS 485

Modbus bus

ATV 31

ATV 58

ATV 71

TeSys model U

ATS 48

Modbus multidrop connection


533184

PLC (1)

PowerSuite

Ethernet TCP/IP network

Bridge

Modbus bus

ATV 31

ATS 48

ATV 58

ATV 71

Ethernet connection

Presentation: page 178

Catalog numbers: page 181

Global Catalog. Refer to Statement of Scope on page 2.

179

180

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers

PowerSuite software workshop

Catalog numbers
PowerSuite software workshop for PC or Pocket PC
Description
533187

Composition

Catalog number

VW3 A8 104

VW3 A8 114

VW3 A8 104 b 1 program for PC and for Pocket PC in English, French, German, Italian and Spanish b Technical documentation b ABC configurator program for the LUF Pp communication gateways PowerSuite update CD-ROM b 1 program for PC and for Pocket PC in English, French, VW3 A8 105 0.100 (1) German, Italian and Spanish b Technical documentation and ABC configurator program VW3 A8 106 0.350 Connection kit for PC serial b 1 x 3 m cable with 2 RJ 45 connectors port b 1 RS 232/RS 485 converter with one 9-way female SUB-D connector and one RJ 45 connector b 1 RJ45/9-way SUB-D adaptor for connecting ATV 38/58/58F drives b 1 RJ45/9-way SUB-D adaptor for connecting ATV 68 drives b 1 converter for the ATV 11 drive, with one 4-way male connector and one RJ45 connector adaptor Modbus-Bluetooth VW3 A8 114 0.155 b 1 Bluetooth adaptor (10 m range, class 2) (3) with 1 RJ45 connector b 1 x 0.1 m cable with 2 RJ 45 connectors for PowerSuite b 1 x 0.1 m cable with 1 RJ 45 connector and 1 mini DIN connector, for TwidoSoft b 1 RJ45/9-way SUB-D adaptor for connecting ATV 58/58F drives USB-Bluetooth adaptor This adaptor is required for a PC which is not equipped VW3 A8 115 0.290 for PC with Bluetooth technology. It is connected to a USB port on the PC. Range of 10 m (class 2). XGS Z24 0.105 RS 232-RS 485 interface b 1 Modbus multidrop converter for connection to screw terminals. Requires a 24 V c (20...30 V), 20 mA power supply (4). (1) Updates a version u V1.40 with the latest available version. For versions < V1.40, you should order the PowerSuite CD-ROM, VW3 A8 104. (2) This kit connects to the serial synchronization cable, which must be ordered separately from the supplier of the Pocket PC. (3) Can also be used to communicate between a Twido PLC and the TwidoSoft software workshop. (4) Please consult our specialist Interfaces, I/O splitter box and power supply catalogue. PowerSuite CD-ROM

Weight kg 0.100

533188

Compatibility
Connection Controllerstarter TeSys model U V1.40 Soft start/soft Drives stop unit ATS 48 ATV 11 ATV 31 ATV 58 ATV 71 ATV 58F V1.0 V1.50 V1.50 V2.2 V1.20 PowerSuite software versions V1.50 V1.30 V2.2 V2.2 V2.2 V2.2

Compatibility of the PowerSuite software workshop for PC with the following devices (minimum version)
Modbus serial link (ATV 68: specific protocol) Ethernet (device equipped with an Ethernet TCP/IP card) Ethernet via Modbus Ethernet bridge Bluetooth Modbus serial link Connection Operating system V1.30 V1.50 V2.2 V1.30 V1.40 V1.40 V2.0 V2.0 V2.2 V2.0

V2.2 V1.50

Compatibility of the PowerSuite software workshop for Pocket PC with the following devices (minimum version) Compatibility of the PowerSuite software workshop with Pocket PCs
Performance tested models

Modbus serial link Windows MobileTM 2003 for Pocket PC Windows for Pocket PC 2002 Windows for Pocket PC 2000 Windows CE Compatible devices and/or software versions Incompatible devices and/or software versions

Hewlett Packard IPAQ 2210 Compaq IPAQ series 3800, 3900 Hewlett Packard Jornada series 560 Hewlett Packard Jornada 525, 545, 548 Hewlett Packard Jornada 420

Presentation: page 178

Functions: pages 178 to 180

Global Catalog. Refer to Statement of Scope on page 2.

181

Presentation

Starters, drives and communication


Ethernet TCP/IP network
Transparent Ready concept

Presentation
Introduced by Schneider Electric, the Transparent Ready concept enables transparent communication between control system devices, production and management. Network technologies and the associated new services are used to share and distribute data between sensors, PLCs, workstations and third-party devices in an increasingly efficient manner. Web servers embedded in the network components and control system devices can be used to: b Access configuration data transparently b Perform remote diagnostics b Incorporate simple human/machine interface functions This concept is based on the Ethernet TCP/IP industrial standard which proposes a single network that meets most communication requirements fromsensors/actuators through to production management systems. Where a variety of communication systems are usually required, Transparent Ready standard technologies can result in significant cost savings in the areas of definition, installation, maintenance or training. Transparent Ready is based on: b Ethernet TCP/IP-based services meeting control system requirements in terms of functions, performance and quality of services b Products including several ranges of PLC, distributed I/O, industrial terminals, variable speed drives, gateways and an increasing number of partner products b The ConneXium range of cabling accessories: hubs, switches, cables adapted to the environment and to the requirements of industrial conditions.

Services

Network management

Global Data

FDR automatic reconfiguration

Web Server

Messaging

Modbus I/O Scanning MIB Transparent Ready

Applications Transport

SNMP

NDDS

DHCP

TFTP

FTP

HTTP

Modbus

UDP

TCP

Link

IP

Physical

Ethernet 802.3 and Ethernet II

Services based on Ethernet TCP/IP

The following Altivar variable speed drives can be connected to the Ethernet TCP/IP network: b Altivar 58 drive via a VW3 A58 310 communication card b Altivar 71 drive via a VW3 A3 310 communication card These cards are supplied with a standard Web server. It is fully modifiable by the user according to the application (JAVA or FactoryCast development tool).

Characteristics: page 183

Functions: pages 183 to 185

Connections: page 186

Catalog numbers: pages 186 and 187

182

Global Catalog. Refer to Statement of Scope on page 2.

Characteristics, functions

Starters, drives and communication


Ethernet TCP/IP network
Transparent Ready concept

Characteristics
Structure Topology Transmission mode Data rate Medium Length of network Type of device Universal services Transparent Ready services Industrial local area network conforming to ANSI/IEEE 802.3 (4th edition 1993-07-08) Star network Manchester baseband. Half-duplex or full-duplex 10/100 Mbps with automatic recognition STP double shielded twisted pair, impedance 100 15 for 10 BASE-T or category 5 Ethernet cable, conforming to standard TIA/EIA-568A 100 m maximum between Hub or switch and a station ATV 58, ATV 71 HTTP, BOOTP, DHCP, FTP, TFTP, SNMP Modbus messaging, IO Scanning, FDR

Universal services
HTTP Hypertext Transfer Protocol (RFC 1945) HTTP Hypertext Transfer Protocol is a protocol used to transmit Web pages between a server and a browser. HTTP has been used on the Web since 1990. Web servers embedded in control system devices are at the heart of the Transparent Ready concept and provide easy access to devices anywhere in the world using a standard web browser such as Internet Explorer or Netscape Navigator. BOOTP/DHCP (RFC 1531) BOOTP/DHCP is used to supply devices (client) automatically with IP addresses and parameters. This avoids having to manage the addresses of each device individually by transferring their management to a server. BOOTP identifies the client device by its Ethernet MAC address. This address is unique to each device, and should be entered in the server each time the device is changed. DHCP Dynamic Host Configuration Protocol identifies the client device by a name in plain language (Device Name) which is maintained throughout the application (eg: Conveyor 23). Altivar 71 and Altivar 58 drives can be given a name (Device Name) by the terminal or the PowerSuite software workshop. Telemecanique has used the standard BOOTP/DHCP protocols in order to offer the faulty device replacement (FDR) service. FTP File Transfer Protocol (RFCs 959, 2228, and 2640) FTP (File Transfer Protocol) supplies the standard file sharing elements. The FTP protocol is used by numerous systems to exchange files between devices. Transparent Ready devices implement FTP in order to transfer certain data from or to devices, especially for downloading firmware or custom Web pages. SNMP Simple Network Management Protocol (RFCs 1155, 1156 and 1157) The Internet community has developed the SNMP standard to enable management of the various network components by means of a single system. The network management system can exchange data with SNMP agent devices. This function allows the manager to view the status of the network and products, to modify their configuration and to feed back alarms in the event of a fault. Transparent Ready devices are compatible with SNMP and can be integrated naturally into a network administered via SNMP.

Presentation: page 182

Connections: page 186

Catalog numbers: pages 186 and 187

Global Catalog. Refer to Statement of Scope on page 2.

183

Functions (continued)

Starters, drives and communication


Ethernet TCP/IP network
Transparent Ready concept

Transparent Ready services


Modbus communication standard Modbus, the industry communication standard since 1979, has been ported to Ethernet TCP/IP, the backbone of the Internet revolution, to create Modbus TCP/IP, a totally open protocol on Ethernet. There is no need for any proprietary component, nor the purchase of a licence in order to develop a connection to Modbus TCP/IP. This protocol can easily be ported to any device supporting a standard TCP/IP communication stack. The specifications can be obtained free of charge from the web site: www.modbus.org.
Modbus TCP, simple and open

The Modbus application layer is very simple and universally familiar. Thousands of manufacturers are already implementing this protocol. Many have already developed a Modbus TCP/IP connection and numerous products are currently available. The simplicity of Modbus TCP/IP enables any small field device, such as an I/O module, to communicate on Ethernet without the need for a powerful microprocessor or a large amount of internal memory.
Modbus TCP, high performance

Due to the simplicity of its protocol and the fast data rate of Ethernet 100 Mbps, the performance of Modbus TCP/IP is excellent. This means that this type of network can be used in realtime applications such as I/O Scanning. I/O Scanning service
Schematic diagram

%MW word table Write Read

Premium

Ethernet TCP/IP

Input words Drive output words Momentum Altivar 58 Altivar 71 Altivar 71

The Altivar 58 and Altivar 71 drives accept the I/O scanning service generated by: b The following automation platforms: v Premium equipped with a TSX ETY 410/5101 module v Quantum v Momentum M1E b A PC equipped with Modbus communication software with the I/O scanner function This service is used to manage the exchange of remote I/O on the Ethernet network after simple configuration and without the need for special programming. The drive I/O are scanned transparently by means of read/write requests according to the Modbus master/slave protocol on the TCP/IP profile. The I/O Scanning service can be configured, activated or deactivated by: b The PowerSuite software workshop b The standard Web server

Presentation: page 182

Characteristics: page 183

Connections: page 186

Catalog numbers: pages 186 and 187

184

Global Catalog. Refer to Statement of Scope on page 2.

Functions (continued)

Starters, drives and communication


Ethernet TCP/IP network
Transparent Ready concept

Transparent Ready services (continued)


Faulty Device Replacement (FDR) service The FDR service uses standard BOOTP, DHCP, file management and TFTP technologies in the aim of simplifying the maintenance of Ethernet devices. It is used to replace a faulty device with a new product, ensuring its detection, reconfiguration and automatic restarting by the system, without the need for any delicate manual intervention. The main steps are: b A device using the FDR service becomes faulty. b A similar device is taken out of the maintenance reserve base, preconfigured with the Device_name of the faulty device, then reinstalled on the network. b The FDR server (which can be a Quantum or Premium PLC Ethernet module) detects the new arrival, configures it with its IP address and transfers all its configuration parameters to it. b The substituted device checks that the parameters are fully compatible with its own characteristics, then switches to operational mode.

Web server
The Ethernet cards in Altivar 58 and Altivar 71 drives incorporate a standard Web server, in English. The functions provided by this Web server require no special configuration or programming of the PC supporting the Internet browser. Using a password, two levels of access can be defined to the web server: read-only or modification. The standard Web server provides access to the following functions: b Altivar Viewer b Data Editor b Ethernet Statistics b Security b Etc The standard Web server can be adapted or replaced by a customized Web server depending on the requirements of the application. Knowledge of HTTP protocol and JAVA technology is required in order to make modifications.

Presentation: page 182

Characteristics: page 183

Connections: page 186

Catalog numbers: pages 186 and 187

Global Catalog. Refer to Statement of Scope on page 2.

185

Connections, catalog numbers

Starters, drives and communication


Ethernet TCP/IP network
Transparent Ready concept

Connections
Redundant fibre optic ring 200 Mbps Full-duplex

Switch Premium

Switch Transceiver Optical fibre

Switch Hub Premium

Hub Transceiver

Quantum Fibre optic loop Hub Hub Hub

Gateway Gateway

ATV 71

ATV 31

ATS 48

Magelis XBT

Advantys STB

ATV 71

ATS 48

ATV 58

Momentum

ATV 71

Ethernet network connection elements


Communication interfaces
Description Communication cards equipped with an RJ45 connector Ethernet Modbus TCP/IP 10/100 Mbps Class B 20 Ethernet/Modbus bridge with 1 x 10BASE-T/100BASE-TX Ethernet port (RJ45 type) For devices ATV 58 (1) ATV 71 ATS 48 ATV 31 Catalog number VW3 A58 310 VW3 A3 310 174 CEV 300 20 (2) Weight kg 0.300 0.300 0.500

522077

Connecting cables
Description 174 CEV 300 20 Straight shielded twisted pair cables 2 RJ45 connectors Used From To 499 NpH 1pp 10 ATV 58 hubs, (+VW3 A3 310 communication card), 499 NpS 171 00 switches ATV 71 (+VW3 A3 310 communication card), Ethernet/Modbus bridge 174 CEV 300 20 Length m 2 5 12 40 80 Cable for Modbus bus 1 RJ45 connector and one stripped end ATS 48, ATV 31 Ethernet/Modbus bridge 174 CEV 300 20 3 Catalog number (3) 490 NTW 000 02 490 NTW 000 05 490 NTW 000 12 490 NTW 000 40 490 NTW 000 80 VW3 A8 306 D30 Weight kg

(1) At 100 Mbps, connection of the VW3 A58 310 communication card on the Ethernet network via a switch only authorizes data exchange in Half Duplex mode. It is vital to use the hubs or switches recommended above on which it is possible to configure Half Duplex mode. (2) Please consult our specialist Automation platform Modicon Premium and Unity - PL7 software catalogue. (3) Cable conforming to category 5 EIA/TIA-568 standard and IEC 1180/EN 50 173, class D. For UL and CSA 22.1 approved cables, add the letter U at the end of the reference. Example: 490 NTW 000 02 becomes 490 NTW 000 02U.

Presentation: page 182

Characteristics: page 183

Functions: pages 183 to 185

186

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers (continued)

Starters, drives and communication


Ethernet TCP/IP network
Transparent Ready concept

530141

Ethernet network connection elements (continued)


Accessories (1)
Description Hubs (2) Type of Ethernet network 10 Mbps Available ports 4 x 10BASE-T ports 3 x 10BASE-T ports 2 x 10BASE-FL ports 100 Mbps 499 NEH 104 10 Switches (2) 5 x 10BASE-T/100BASE-TX 499 NES 171 00 0.460 ports 2 x 100BASE-TX ports 5 x 10BASE-T/100BASE-TX 499 NOS 171 00 0.460 ports 2 x 100BASE-FX ports (1) For Transparent Ready accessories, please consult our specialist Ethernet TCP/IP, Transparent Factory catalogue. (2) At 100 Mbps, connection of the VW3 A58 310 communication card on the Ethernet network via a switch only authorizes data exchange in Half Duplex mode. It is vital to use the hubs or switches recommended above on which it is possible to configure Half Duplex mode. 10/100 Mbps 4 x 100BASE-TX ports Catalog number 499 NEH 104 10 499 NOH 105 10 Weight kg 0.530 0.900

499 NEH 141 10

0.240

530142

499 NES 171 00

Presentation: page 182

Characteristics: page 183

Functions: pages 183 to 185

Connections: page 186

Global Catalog. Refer to Statement of Scope on page 2.

187

Presentation

Starters, drives and communication


Communication via Fipio bus

Presentation
Premium Magelis XBT

Fipio bus

LUF P1

Advantys STB ATV 71 ATV 58

ATV 31 ATS 48

The Fipio fieldbus is a standard means of communication between control system components, and conforms to the World FIP standard. A Premium PLC (bus manager) can control 127 devices (agents) over a maximum distance of 15 km. The Fipio bus manager is integrated in the PLC processor. The Altistart 48 soft start/soft stop unit and the Altivar 31 variable speed drive can be connected to the Fipio bus via an LUF P1 Fipio/Modbus gateway. The following Altivar variable speed drives are connected to the Fipio network via a communication card: b VW3 A58 311 card for the Altivar 58 drive b VW3 A3 311 card for the Altivar 71 drive The following devices can also be connected to the Fipio bus: b TSX Micro (2) or Premium Agent function (1) PLCs b The CCX 17 operator panel (2) b The Magelis XBT-F terminal with graphic screen (3) b The Magelis iPC industrial PC (3) b Advantys STB IP 20 distributed I/O (4) b Discrete, analog or application-specific Momentum distributed I/O (5) b Discrete or analog (IP 20) TBX distributed I/O (1) b TBX discrete (IP 65) or TSX EpF (IP67) dust and damp proof distributed I/O (1) b The TBX SAP 10 Fipio/AS-Interface gateway (1) b The LUF P1 Fipio/Modbus gateway b A PC terminal b Partner products in the Collaborative Automation programme
(1) Please consult our specialist Automation platform Modicon Premium and Unity - PL7 software catalogue. (2) Please consult our specialist Automation platform Modicon TSX Micro and PL7 software catalogue. (3) Please consult our specialist Human/Machine interfaces catalogue. (4) Please consult our specialist Distributed I/O Advantys STB catalogue. (5) Please consult our specialist Modicon Momentum Automation platform catalogue.

Characteristics: page 189

Connections: page 190

Catalog numbers: pages 190 and 191

188

Global Catalog. Refer to Statement of Scope on page 2.

Characteristics

Starters, drives and communication


Communication via Fipio bus

Characteristics
Structure Topology Industrial bus conforming to the World FIP standard Subscribers linked via daisy-chain or tap junctions Producer/consumer principle Bus management by a fixed arbitrator (bus manager) Baseband physical layer on shielded twisted pair, according to standard NF C 46-604 1 Mbps Shielded twisted pair 150 . Optical fibre 62.5/125 with the use of electrical/fibre optic repeaters 32 maximum per segment 1 manager + 127 agents maximum over all segments The number of Fipio agents is limited by the memory capacity of Premium processors (62 Altivar drives maximum) (1) Unlimited in tree or star architectures Limited to 5 cascaded segments The link between 2 subscribers may cross 4 electrical or electrical/fibre optic repeaters maximum 15,000 m maximum 1,000 m maximum without repeater for an electrical segment 5,000 m maximum for 5 electrical segments 3,000 m maximum for 1 fibre optic segment ATS 48, ATV 31 LUF P1 FED C 32P 26 configurable words (2) 26 configurable words (2) ATV 58 VW3 A58 311 FED C 32 5 predefined words 8 predefined words ATV 71 VW3 A3 311 FED C 32 8 configurable words (communication scanner) 8 configurable words (communication scanner)

Access method

Transmission mode Data rate Medium

Number of subscribers

Number of segments

Length of bus

Type of device Type of interface Profile Control and adjustment Monitoring Configuration and adjustment

1 indexed word Read/write access to all functions by the PLC application program (1) Please consult our specialist Automation platform Modicon Premium and Unity - PL7 software catalogue. (2) 26 words in total for control and monitoring. To extend the I/O capacity to 26 control words and 26 monitoring words, use the ABC Configurator software (see page 181).

Presentation: page 188

Connections: page 190

Catalog numbers: pages 190 and 191

Global Catalog. Refer to Statement of Scope on page 2.

189

Connections, catalog numbers

Starters, drives and communication


Communication via Fipio bus

Fipio wiring system


6
Premium ATV 71 ATV 71 ATV 58

4 3 14 11

6
c 1960 V

8 4 13
c 1960 V

1 2 2

4 12 6 7 6 4 6

8 9 14

11 10 14

11

11

11
c 2448 V

11

ATV 31

ATS 48

Elements for connecting the Fipio bus and a Premium PLC (1)
Cards and gateway
Description Used for ATV 58 Code Catalog number Weight kg 0.300

LUF P1

1 VW3 A58 311 Fipio card The card is equipped with a 9-way male SUB-D connector, which can take a TSX FP ACC12 connector with a TSX FP CAp00 trunk cable or TSX FP CCp00 drop cable. ATV 71 2 VW3 A3 311 0.300 Standard Fipio card The card is equipped with a 9-way male SUB-D connector, which can take a TSX FP ACC12 connector with a TSX FP CAp00 trunk cable or TSX FP CCp00 drop cable. This card should be used for new installations. It is also used to replace an ATV 58 or ATV 58F equipped with a VW3 A58 311 card by an ATV 71. Substitution Fipio card ATV 71 2 VW3 A3 301 0.300 The card is equipped with a 9-way male SUB-D connector, which can take a TSX FP ACC12 connector with a TSX FP CAp00 trunk cable or TSX FP CCp00 drop cable. This Fipio communication card is reserved for replacing an ATV 58 or ATV 58F equipped with a VW3 A58 301 card by an ATV 71. Fipio/Modbus gateway ATS 48 3 LUF P1 0.240 The gateway is equipped with: ATV 31 b 1 Fipio 9-way male SUB-D connector which will take a TSX FP ACC12 connector for use with a TSX FP CAp00 trunk cable or TSX FPCCp00 drop cable b 1 RJ45 connector for Modbus for connection with the VW3 A8 306 Rpp cable Fit an external 24 V c power supply, 100 mA minimum, to be ordered separately (2). (1) To order other elements for connection to the Fipio bus, please consult our specialist Automation platform Modicon Premium and Unity - PL7 software catalogue. (2) Please consult our specialist Interfaces, I/O splitter boxes and power supplies catalogue.

533148

Presentation: page 188

Characteristics: page 189

190

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers (continued)

Starters, drives and communication


Communication via Fipio bus

Elements for connecting the Fipio bus and a Premium PLC (continued) (1)
Accessories
Description Female connector for device with 9-way female SUB-D connector (polycarbonate, IP 20) Tap junction (polycarbonate, IP 20) Fipio line terminators (sold in lots of 2) Electrical repeater (IP 65) Power supply 24 V c, 150 mA (2) 48 Electrical/fibre optic repeater (IP 65) Power supply 19 Vc, 210 mA (2) 60 Modbus splitter block equipped with 10 RJ45 connectors and 1 screw terminal Modbus line terminators (3) FIP wiring test tool Use Code Unit catalog number TSX FP ACC12 Weight kg 0.040

Connection via daisy-chain or tap junctions. 4 For ATV 58, ATV 71, LUF P1 gateway and Premium PLC Trunk cable tap link 5 Connector, tap junction and repeater Increases the length of the bus while enabling connection of 2 segments of 1000 m maximum Used for connection (via a patch panel) of an electrical segment (1000 m max.) and a fibre optic segment (3000 m max.) Used to connect an ATV 31, ATS 48 on the LUP P1 gateway LU9 GC3 Modbus splitter block Used to test each section of a network segment Used From TSX FP ACC12 connector, TSX FP ACC14 junction box, TSX FP ACC6, ACC8M repeaters TSX FP ACC12 connector, TSX FP ACC14 junction box, TSX FP ACC6, ACC8M repeaters TSX FP ACC12 connector Code To TSX FP ACC12 11 connector, TSX FP ACC14 junction box, TSX FP ACC6 repeater TSX FP ACC12 11 connector, TSX FP ACC14 junction box, TSX FP ACC6 repeater TSX FP ACC14 12 junction box 6 7

TSX FP ACC14 TSX FP ACC7 TSX FP ACC6

0.120 0.020 0.520

TSX FP ACC8M

0.620

LU9 GC3

0.500

10

VW3 A8 306 RC TSX FP ACC9

0.010 0.050

Connecting cables (1)


Description Trunk cables 8 mm, 1 shielded twisted pair 150 . In standard atmosphere (4) and inside buildings Length m 100 200 500 Catalog number TSX FP CA100 TSX FP CA200 TSX FP CA500 Weight kg 5.680 10.920 30.000

Trunk cables 9.5 mm, 1 shielded twisted pair 150 . In harsh environments (5), outside buildings or in mobile installations (6)

100 200 500

TSX FP CR100 TSX FP CR200 TSX FP CR500

7.680 14.920 40.000

Drop cables 8 mm, 2 shielded twisted pairs 150 . In standard atmosphere (4) and inside buildings Fibre optic jumper Double optical fibre 62.5/125 Cables for Modbus bus 2 RJ45 connectors

100 200 500 2 0.3 1 3

TSX FP CC100 TSX FP CC200 TSX FP CC500 TSX FP JF020 VW3 A8 306 R03 VW3 A8 306 R10 VW3 A8 306 R30

5.680 10.920 30.000 0.550 0.025 0.060 0.130

TSX FP ACC8M repeater LUF P1 gateway, ATS 48, ATV 31

Patch panel

13

LU9 GC3 14 Modbus splitter block

Documentation
The manuals and quick reference guides for starters and variable speed drives, as well as the user manuals for communication gateways, are available on the web site: www.telemecanique.com. (1) To order other elements for connection to the Fipio bus, please consult our specialist Automation platform Modicon Premium and Unity - PL7 software catalogue. (2) Please consult our specialist Interfaces, I/O splitter boxes and power supplies catalogue. (3) Sold in lots of 2. (4) Standard environment: - no particular environmental constraints - operating temperature between + 5C and + 60C - fixed installation (5) Harsh environment: - withstand to hydrocarbons, industrial oils, detergents, solder splashes - relative humidity up to 100% - saline atmosphere - significant temperature variations - operating temperature between -10C and +70C - mobile installation (6) Mobile installation: cables in accordance with VDE 472 part 603/H: - use on a cable-carrier chain with bending radius 75 mm minimum - use on a gantry, provided that operating conditions such as acceleration, speed, length, etc are adhered to: please consult your Regional Sales Office - unauthorised use on robots, or multi-axis applications

Presentation: page 188

Characteristics: page 189

Connections: page 190

Global Catalog. Refer to Statement of Scope on page 2.

191

Presentation, characteristics

Starters, drives and communication


Communication via Modbus bus

Presentation
Quantum Premium TSX Micro Twido

Modbus bus

ATV 31 ATV 71 ATV 58 ATS 48

Modbus is a master/slave protocol. Two exchange mechanisms are possible: b Request/response: The request from the master is addressed to a given slave. The master then waits for the response from the slave which has been interrogated. b Broadcasting: The master broadcasts a request to all the slave stations on the bus, which execute the command without transmitting a response. The Altistart 48 soft start/soft stop unit, Altivar 31 and Altivar 58 variable speed drives are connected to the Modbus bus via their terminal port. On the Altivar 58 drive, the terminal port can be freed up for connection of the operator terminal by using a communication card. The Altivar 71 variable speed drive includes the Modbus protocol as standard. It can be accessed directly by means of 2 integrated communication ports: b A terminal port for connection of the graphic display terminal or an industrial HMI terminal (Magelis type) b Modbus network port As an option, the Altivar 71 drive can also be equipped with a VW3 A3 303 Modbus/ Uni-Telway communication card which offers additional characteristics (4-wire RS 485, ASCII mode, etc).

Characteristics
Type of device Type of connection Structure Connector ATS 48 ATV 31 Terminal port RJ45 RJ45 ATV 58 9-way female SUB-D ATV 71 RJ45 ATV 71 Network port RJ45 ATV 58, ATV 71 Communication card 9-way female SUB-D

Topology Physical interface Access method Transmission mode Data rate 38.4 Kbps 19.2 or 9.6 Kbps 4.8 Kbps Medium Number of subscribers Type of polarization

Length of bus Tap link

Bus 2-wire RS 485 Master/slave RTU p p p p p p p p p Double shielded twisted pair 18, 27 or 31 slaves, depending on polarization (1) 4.7 k No 4.7 k No No pulldown pulldown pulldown pulldown pulldown resistors resistors 1000 or 1300 m excluding tap links, depending on polarization (1) 3 or 20 m maximum, depending on polarization (1) (1) See the configuration table on page 193.

2-wire or 4-wire RS 485 RTU or ASCII p p

Configurable. No pulldown or 4.7 k pulldown resistors

Connections: pages 193 and 194

Catalog numbers: pages 193 to 195

192

Global Catalog. Refer to Statement of Scope on page 2.

Connections, catalog numbers

Starters, drives and communication


Communication via Modbus bus

Configuration on the basis of polarization


The specification of the physical layer provided by standard RS 485 is incomplete. Various polarization diagrams can therefore be applied depending on the environment in which the equipment is to be used. The Modbus standard specifies the polarization exactly (1).
Master With polarization 4.7 k Configuration not recommended.

Slave

Without polarization

With polarization 4.7 k

Uni-Telway type configuration 27 slaves. Length of bus: 1,000 m Tap link: 20 m maximum. RC line terminators (R =120 , C = 1 nF) .

With polarization 470 Modbus type configuration 31 slaves. Length of bus: 1,300 m Tap link: 3 m maximum. RC line terminators (R =120 , C = 1 nF) . Mixed configuration 18 slaves. Length of bus: 1,000 m Tap link: 20 m maximum. RC line terminators (R =120 , C = 1 nF) .

PLC

Connection elements for RJ45 wiring system


Card
Description Used with ATV 71 Catalog number VW3 A3 303 Weight kg 0.300

(2)

Communication card

4 2 4

2 4 2 3 equipped with one 9-way female SUB-D connector Accessories


Description Code 1

3 4 5

2
Modbus splitter block 10 RJ45 connectors and 1 screw terminal block Modbus T-junction boxes With integrated cable (0.3 m) With integrated cable (1 m) R = 120 C = 1 nF R = 150

Unit catalog number LU9 GC3

Weight kg 0.500

2 2 3 3

VW3 A8 306 TF03 VW3 A8 306 TF10 VW3 A8 306 RC VW3 A8 306 R

0.200 0.010

Starters/drives

Line terminators For RJ45 connector (3)

522184

Cables
Description Cables for Modbus bus 2 RJ45 connectors Used Code From To LU9 GC3 Modbus 4 ATS 48, splitter block ATV 31, ATV 71 (connector ports or Modbus network) VW3 A8 306 TFpp Modbus T-junction box LU9 GC3 Modbus splitter block ATV 58 (terminal port) ATV 58 (+VW3 A58 303 kit) ATV 71 (+ VW3 A3 303 communication card) LU9 GC3 Modbus splitter block (screw terminals) VW3 A8 306 TFpp Modbus T-junction box LU9 GC3 Modbus splitter block LU9 GC3 Modbus 4 splitter block Length m 0.3 1 3 Catalog number VW3 A8 306 R03 VW3 A8 306 R10 VW3 A8 306 R30 Weight kg 0.025 0.060 0.130

LU9 GC3

532174

Cables for Modbus bus One 9-way male SUB-D connector and one RJ45 connector

1 3

VW3 A58 306 R10 VW3 A58 306 R30

0.080 0.150

VW3 A8 306 TFpp

Double shielded twisted pair cables

LU9 GC3 Modbus 5 splitter block (screw terminals)

100 200 500

TSX CSA 100 TSX CSA 200 TSX CSA 500

5.680 10.920 30.000

(1) Standard defined in 2002, available on the web site: www.modbus.org. (2) The cable for connecting the PLC and the splitter block depends on the type of PLC ; please consult our specialist Automation platform Modicon Premium and Unity - PL7 software, Automation platform Modicon Quantum, Automation platform Modicon TSX Micro and PL7 software and Automation and relay functions catalogues. (3) Sold in lots of 2.

Presentation: page 192

Characteristics: page 192

Global Catalog. Refer to Statement of Scope on page 2.

193

Connections, catalog numbers (continued)

Starters, drives and communication


Communication via Modbus bus

PLC

Connection elements using tap junctions


Kit
Description Used with For protocol Catalog number VW3 A58 303 Weight kg 0.300

(1)

ATV 58 Uni-Telway, Communication kit with operator terminal Modbus ASCII, comprising: Modbus RTU/Jbus b 1 communication card equipped with one 9-way female SUB-D connector b 1 x 3 m cable equipped with: v One 9-way male SUB-D connector for connection to the communication card v One 15-way male SUB-D connector for connection to a TSX SCA 62 subscriber socket b 1 Modbus, Uni-Telway users manual

Starters/drives
533178

Accessories
Description Tap junction 3 screw terminals, RC line terminator TSX SCA 50 Subscriber socket Two 15-way female SUB-D connectors and 2 screw terminals, RC line terminator Code 1 Catalog number TSX SCA 50 Weight kg 0.520

TSX SCA 62

0.570

533179

TSX SCA 62

Cables
Description Double shielded twisted pair cables Used From TSX SCA 50 junction box, TSX SCA 62 subscriber socket Code To TSX SCA 50 junction box, TSX SCA 62 subscriber socket 3 Length m 100 200 500 Cable for Modbus bus 1 RJ45 connector and one stripped end Cable for Modbus bus 1 RJ45 connector and one 15-way male SUB-D connector Cable for Uni-Telway and Modbus bus 2 male SUB-D connectors, 9 and 15-way ATS 48, ATV 31, ATV 71 (terminal ports or Modbus network) ATS 48, ATV 31, ATV 71 (terminal ports or Modbus network) ATV 71 (+ VW3 A3 303 communication card) TSX SCA 50 junction box 4 3 Catalog number TSX CSA 100 TSX CSA 200 TSX CSA 500 VW3 A8 306 D30 Weight kg 5.680 10.920 30.000 0.150

TSX SCA 62 subscriber socket

VW3 A8 306

0.150

TSX SCA 62 subscriber socket

VW3 A8 306 2

0.150

(1)The cable for connecting the PLC and the splitter block depends on the type of PLC ; please consult our specialist Automation platform Modicon Premium and Unity - PL7 software, Automation platform Modicon Quantum, Automation platform Modicon TSX Micro and PL7 software and Automation and relay functions catalogues.

Presentation: page 192

Characteristics: page 192

194

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers (continued)

Starters, drives and communication


Communication via Modbus bus

Connection elements using tap junctions (continued)


Cables
Used From ATV 58 RS 485 connection kit without operator comprising: b 1 x 3 m cable equipped with: terminal (terminal port) v One 9-way male SUB-D connector v One 15-way male SUB-D connector b 1 RS 485 users manual b 1 Communication variables user's manual Description To TSX SCA 62 subscriber socket For protocol Modbus RTU Catalog number VW3 A58 306 Weight kg 0.300

Connection elements using screw terminals


Accessories
Description Line terminators (1) for screw terminals R = 120 , C = 1 nF R = 150 Unit catalog number VW3 A8 306 DRC Weight kg 0.200

VW3 A8 306 DR

0.200

Cable
Description Cable for Modbus 1 RJ45 connector and one stripped end Used From ATS 48, ATV 31, ATV 71 (terminal ports or Modbus network) To Standard screw terminals, TSX SCA 50 junction box Length m 3 Catalog number VW3 A8 306 D30 Weight kg 0.150

Documentation
The manuals and quick reference guides for starters and variable speed drives, as well as the user manuals for communication gateways, are available on the web site: www.telemecanique.com. (1) Sold in lots of 2.

Presentation: page 192

Characteristics: page 192

Connections: pages 193 and 194

Global Catalog. Refer to Statement of Scope on page 2.

195

Presentation

Starters, drives and communication


Communication via Modbus Plus network

Presentation
Quantum

Premium

Modbus Plus network

Gateway

Advantys STB ATV 58 ATV 71

ATV 31 ATS 48

The Modbus Plus network is a high-performance industrial local area network which can be used to meet the needs of client/server type extended architectures, combining a high data rate (1 Mbps), simple low-cost transmission media and numerous messaging services. The Altistart 48 soft start/soft stop unit and the Altivar 31 variable speed drive can be connected to the Modbus Plus network via an NW BM85000 gateway which has four RS 232 serial ports. The following Altivar variable speed drives are connected to the Modbus Plus network via a communication card: b VW3 A58 302 card for the Altivar 58 drive b VW3 A3 302 card for the Altivar 71 drive Communication services The main data exchange services between subscribers connected to the network are: b The Modbus messaging service according to Modbus protocol b The Global Data service: each subscriber makes available 32 words for each of the 63 other network subscribers b The Peer Cop dialogue service: point-to-point transaction of 32 receive or transmit words The Global Data and Peer Cop services are restricted to a Modbus Plus network with a maximum of 64 subscribers. Altivar 58 and Altivar 71 drives are accessed by simple configuration in the PLC using Peer Cop and Global Data services. These services enable rapid exchange of the main drive parameters: b The Peer Cop service for controlling and adjusting the drive b The Global data service for monitoring the drive Other parameters, which are used less frequently, can be accessed by the Modbus messaging service.

Characteristics: page 197

Connections: page 198

Catalog numbers: pages 198 and 199

196

Global Catalog. Refer to Statement of Scope on page 2.

Characteristics

Starters, drives and communication


Communication via Modbus Plus network

Characteristics
Structure Topology Physical interface Access method Transmission mode Data rate Medium Bus RS 485 Token bus HDLC synchronous 1 Mbps Shielded twisted pair 120 Optical fibre 32, without repeater 64, with one or more repeaters 4, separated by a maximum of 3 bridges 450 m maximum without repeater 1800 m maximum with 3 electrical repeaters 3000 m between 2 fibre optic repeaters Point-to-point requests with confirmation report: 200 bytes maximum, compatible with all Modbus subscribers 4096-byte shared database Cyclic exchange of 32 broadcast words Limited to one network This service does not cross bridges Point-to-point or broadcast message Limited to one network This service does not cross bridges ATS 48, ATV 31 NW BM85000 Modbus messaging ATV 58 VW3 A58 302 Peer Cop 32 predefined words maximum Global Data 32 predefined words maximum ATV 71 VW3 A3 302 Peer Cop 8 configurable words maximum (communication scanner) Global Data 8 configurable words maximum (communication scanner)

Number of subscribers per network Number of networks Length of network

Services

Modbus messaging

Global Data

Peer Cop dialogue

Type of device Type of interface Control

Monitoring

Modbus messaging

Configuration and adjustment

Modbus messaging

Modbus messaging Read/write access to all drive parameters

Presentation: page 196

Connections: page 198

Catalog numbers: pages 198 and 199

Global Catalog. Refer to Statement of Scope on page 2.

197

Connections, catalog numbers

Starters, drives and communication


Communication via Modbus Plus network

Modbus Plus wiring system


Quantum

10
Premium

4
Network # 2

11 8 10 4 11 10 4
Network # 1

11

11

12 6 7
RS 232

2 13

11

RS 485

3 9
Fibre optic link Quantum

ATV 58

ATV 71

13

13

ATS 48

ATV 31

Modbus Plus bus connection elements (1)


Cards and gateways
Description Used with Code 1 1 2 Catalog number VW3 A58 302 VW3 A3 302 NW BM85000 Weight kg 0.300 0.300 3.158

ATV 58 Communication cards equipped with one 9-way female ATV 71 SUB-D connector ATS 48, ATV 31 Modbus Plus/Modbus gateway 4 RS 232 ports power supply 115220 Va RS 232/RS 485 interface ATS 48, ATV 31 power supply 24 V c, 20 mA (2)

XGS Z24

0.105

Connection accessories
Description Use Code Catalog number Weight kg 0.230

Modbus Plus tap For connecting via a tap junction 4 990 NAD 230 00 (IP 20) Modbus Plus in-line connector Gateway, bridge and repeater 5 AS MBKT 085 0.035 6 AS MBKT 185 0.260 Connector with Modbus Plus Bridge and repeater terminator (sold in lots of 2) Modbus Plus electrical repeater Extension beyond 450 m or 7 NW RR85 001 2.677 up to 64 subscribers Modbus Plus bridge with Connection of 4 networks maximum 8 NW BP85 002 2.813 4 ports Line/station fibre optic 9 490 NRP 254 00 2.856 repeater Point-to-point fibre optic Used to connect an electrical segment to NW NRP 253 00 2.863 repeater the fibre optic segment (3000 m maximum) Wiring tool Inserting trunk and drop cables in a 043 509 383 3.000 990 NAD 230 00 tap (1) To order other connection elements, please consult our specialist Automation platform Modicon Premium and Unity - PL7 software and Automation platform Modicon Quantum catalogues. (2) Please consult our specialist Interfaces, I/O splitter boxes and power supplies catalogue.

Presentation: page 196

Characteristics: page 197

198

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers (continued)

Starters, drives and communication


Communication via Modbus Plus network

Modbus Plus bus connection elements (continued) (1)


Cables
Description Trunk cables for Modbus Plus Used From 990 NAD 230 00 Modbus Plus tap Code To 10 990 NAD 230 00 Modbus Plus tap, AS MBKT 085 Modbus Plus in-line connector, Modbus Plus connector with terminators AS MBKT 185 Length m 30.5 152.5 305 457 1525 Drop cables One 9-way male SUB-D connector and one stripped end ATV 58 (+VW3 A58 990 NAD 230 00 302 communication Modbus Plus tap card), Premium, Quantum PLCs, NW BP85 002 Modbus Plus bridge with 4 ports, 490 NRP 253 00 line/ station fibre optic repeater 990 NAD 230 00 ATV 71 Modbus Plus tap (+ VW3 A3 302 communication card) 11 2.4 6 Catalog number 490 NAA 271 01 490 NAA 271 02 490 NAA 271 03 490 NAA 271 04 490 NAA 271 06 990 NAD 211 10 990 NAD 211 30 Weight kg 1.833 10.135 18.940 30.000 112.950 0.169 0.459

12

2.4 6

990 NAD 219 10 990 NAD 219 30

0.142 0.465

RS 232/RS 485 13 3 VW3 A8 306 D30 0.115 ATS 48, ATV 31, interface NW BM85000 Modbus Plus/ Modbus gateway (1)To order other connection elements, please consult our specialist Automation platform Modicon Premium and Unity - PL7 software and Automation platform Modicon Quantum catalogues. Cable for Modbus 1 RJ45 connector and one stripped end

Presentation: page 196

Characteristics: page 197

Connections: page 198

Global Catalog. Refer to Statement of Scope on page 2.

199

Presentation, characteristics, connections,

Starters, drives and communication


Communication via Uni-Telway bus

Presentation
Premium

The Uni-Telway bus is a standard means of communication between control system components (PLCs, HMI terminals, supervisors, variable speed drives, numerical controllers, etc).
TSX Micro

Uni-Telway bus

The Uni-Telway bus requires a master station (Premium, TSX Micro PLCs) which manages the allocation of bus access rights to the various connected slave stations (HMI terminals, variable speed drives, etc). The slave stations can communicate with one another without programming the master station. An industrial HMI terminal (Magelis type) can be connected directly to the bus and can be used to adjust drives without developing applications specific to the PLC. The following Altivar variable speed drives can be connected to the Uni-Telway bus via: b A VW3 A58 303 communication kit for the Altivar 58 drive b A VW3 A3 303 communication card for the Altivar 71 drive

XBT Magelis ATV 71 ATV 58

Characteristics
Structure Topology Physical interface Link Access method Transmission mode Data rate Medium Number of stations Length of bus Tap links UNI-TE Bus RS 485 isolated Multidrop Master/slave type Asynchronous transmission in baseband 4.819.2 Kbps Double shielded twisted pair 28 maximum 1000 m maximum excluding tap links 20 m maximum Request/response of up to 240 bytes (1) initiated by any connected station. Unsolicited point-to-point data of up to 240 bytes (1) without confirmation report, initiated by any connected station. Broadcast messages of up to 240 bytes (1) initiated by the master station. Transparent communication, via the master station, with any X-WAY architecture. Diagnostics, debugging, adjustment, programming of PLCs. Check character on each frame, acknowledgement and, if required, repetition of messages ensure security of transmission. The bus status table, transmission error counters and station status can be accessed on each station.

Services

Other functions Security Monitoring

Uni-Telway bus wiring system


TSX Micro (Terminal port)

Premium + TSX SCY 21601

4 10 5 8 5 8 6 8 7

11 2

11

1 3
Premium + TSX SCP 114

ATV 58

ATV 71

ATV 71

(1) Limited to 128 bytes with the Premium and TSX Micro PLC terminal port.

200

Global Catalog. Refer to Statement of Scope on page 2.

Catalog numbers

Starters, drives and communication


Communication via Uni-Telway bus

Uni-Telway bus connection elements (1)


Cards, kit and module
Description Communication card card equipped with a 9-way female SUB-D connector Communication kit comprising: b 1 communication card equipped with a 9-way female SUB-D connector b 1 x 3 m cable equipped with 2 male SUB-D connectors: v 9-way for connection to the VW3 A3 303 communication card v 15-way for connection to the TSX SCA 62 subscriber socket RS 485 type III PCMCIA card (compatible with RS 422) 1.2...19.2 Kbps Communication module Used with ATV 71 Code 1 Protocol Uni-Telway, Modbus Uni-Telway, Modbus Catalog number VW3 A3 303 Weight kg 0.300

ATV 58

VW3 A58 303

0.300

Premium, Atrium, TSX Micro PLCs or TSX SCY 21601 module Premium or Atrium PLCs

Uni-Telway, Modbus, character mode Uni-Telway, Modbus, character mode

TSX SCP 114

0.105

TSX SCY 21601

0.360

533153

Connection accessories
Description Subscriber socket Two 15-way female SUB-D connectors and 2 screw terminals Tap junction 3 screw terminals Terminal port connection box with integrated cable of length 1 m Use 2-channel junction box, trunk cable extension and line terminator Code 5 Catalog number TSX SCA 62 Weight kg 0.570

TSX SCA 62

533155

Junction box, trunk cable 6 extension and line terminator Connection of a TSX Micro or 7 Premium PLC via the PLC terminal port and line terminator

TSX SCA 50 TSX P ACC 01

0.520 0.690

Cables
Description Uni-Telway double shielded twisted pair cables Used From TSX SCA 50 junction box, TSX SCA 62 subscriber socket, TSX P ACC 01 terminal port connection box TSX SCP 114 card Code To 8 TSX SCA 62 subscriber socket, TSX SCA 50 junction box, TSX P ACC 01 terminal port connection box 9 9 Length m 100 200 500 Catalog number TSX CSA 100 TSX CSA 200 TSX CSA 500 Weight kg 5.680 10.920 30.000

TSX SCA 50
533154

TSX P ACC 01

Cables for isolated RS 485 tap link

Cable for Uni-Telway and Modbus bus 2 male SUB-D connectors, 9 and 15-way

TSX SCA 50 junction box TSX SCA 62 subscriber socket TSX SCA 50 Integrated junction box channel (channel 0) of TSX SCA 62 TSX SCY 2160 subscriber 1 module socket TSX SCA 62 ATV 71 (+VW3 A3 303 subscriber communication socket card)

3 3

TSX SCP CU 4030 TSX SCP CU 4530

0.160 0.180

10 10

3 3

TSX SCP CU 6030 TSX SCY CU 6530

0.180 0.200

11

VW3 A8 306 2

0.150

(1) To order other elements for connection to the Fipio bus, please consult our specialist Automation platform Modicon Premium and Unity - PL7 software and Automation platform Modicon TSX Micro and PL7 software catalogues.

Global Catalog. Refer to Statement of Scope on page 2.

201

Presentation, description, setting-up

Starters, drives and communication


Communication gateways LUF P

Presentation
Communication gateways LUF P allow connection between Modbus and field buses such as Fipio, Profibus DP or DeviceNet. After configuration, these gateways manage information which can be accessed by the Modbus bus and make this information available for read/write functions (command, monitoring, configuration and adjustment) on the field buses. An LUF P communication gateway consists of a box which can be clipped onto a 35 mm omega rail, allowing connection of up to 8 Slaves connected on the Modbus bus. Example of architecture
Configuration of gateway by PC

Model U starter-controllers

LUF P

Fipio Profibus DP DeviceNet

(1) Modbus

561511

ATS 48 ATV 31

1
(1) Connection kit for PowerSuite software workshop.

Description
Front panel of the product 1 LED indicating : - communication status of the Modbus buses, - gateway status, - communication status of the Fipio, Profibus DP or DeviceNet bus. 2 Connectors for connection to Fipio, Profibus DP or DeviceNet buses.

561512

Underside of product 3 RJ45 connector for connection on the Modbus bus 4 RJ45 connector for link to a PC 5 c 24 V power supply 3 4

Software set-up
For the Fipio bus, software set-up of the gateway is performed using either PL7 Micro/Junior/Pro software or ABC Configurator software. For the Profibus DP and DeviceNet buses, software set-up is performed using ABC Configurator. This software is included: b in the PowerSuite software workshop for PC (see page 181), b in the TeSys model U user's manual.
Dimensions : page 203

Characteristics, catalog numbers :page 203 203

202

Global Catalog. Refer to Statement of Scope on page 2.

Characteristics, catalog numbers, dimensions

Starters, drives and communication


Communication gateways LUF P

Characteristics
Bus type Environment Ambient air temperature Degree of protection Electromagnetic compatibility Conforming to IEC 60664 Around the device Fipio Profibus DP DeviceNet Degree of pollution: 2 C + 5+ 50 IP 20 Conforming to IEC 50081-2: 1993 Conforming to IEC 61000-6-2: 1999 y8 By RJ45 connector conforming to Schneider Electric RS485 standard By RJ45 connector, with PowerSuite connection kit By SUB D9 female By SUB D9 female By 5-way removable connector connector screw connector V External supply, c 24 10 % mA 280 mA 100 By LED on front panel FED C32 or FED C32P 26 configurable words (1) 122 configurable words 256 configurable words 26 configurable words (1) 122 configurable words 256 configurable words By gateway mini messaging facility (PKW) (1) If the gateway is configured using PL7 and not ABC Configurator, the I/O capacity is limited to a total of 26 words. For use with TeSys Model U starter-controllers, Altistart 48, Altivar 31 With bus type Fipio/Modbus Profibus DP/Modbus DeviceNet/Modbus Connectors 1 RJ45 type connector and one end with stripped wires 2 RJ45 type connectors 2 RJ45 type connectors 2 RJ45 type connectors 1 SUB-D 9 male connector 1 SUB-D 9 male connector 1 SUB-D 9 male connector Catalog number Weight kg LUF P1 0.245 LUF P7 0.245 LUF P9 0.245 Catalog number Weight kg VW3 A8 306 D30 0.150 VW3 A8 306 R03 VW3 A8 306 R10 VW3 A8 306 R30 TSX FP ACC12 490 NAD 911 04 490 NAD 911 03 0.050 0.050 0.150 0.040

Emission Immunity Number of Modbus slaves which can be connected Connection Modbus To a PC Field bus Supply Consumption Indication/diagnostics Services

Max. Typical Profile Command Monitoring Configuration and adjustment

Catalog numbers
Description Communication gateways

Connection accessories
822631

Description Connection cables TSX FP ACC 12

For use with Modbus (2)

Length m 3 0.3 1 3

822713

Connectors

Fipio Profibus mid line Profibus line end

490 NAD 911 03

Documentation
Description User's manual for TeSys model U range (3) Medium CD-Rom Language Catalog number Weight kg LU9 CD1 0.022

Multilingual : English, French, German, Italian, Spanish (2) See pages 192 and 195. (3) This CD-Rom contains user's manuals for AS-Interface and Modbus communication modules, multifunction control units and gateways, as well as for the gateway programming software, ABC Configurator.

Dimensions

= 75 = 120

27

Presentation, description : page 202

Setting-up : page 202

Global Catalog. Refer to Statement of Scope on page 2.

203

Presentation, description, setting-up

Starters, drives and communication


Communication gateway LA9 P307

Presentation
Communication gateway LA9 P307 provides connection between the Profibus DP and Modbus buses. It is a Slave on the Profibus DP bus and Master on the Modbus bus. It manages information present on the Modbus bus to make it available for read/write functions in the Master PLC on the Profibus DP bus. Gateway LA9 P307 consists of a box which can be clipped onto a 35 mm omega rail. It manages up to15 Slaves on the Modus bus. Example of architecture
Profibus DP

3 2
Modbus

7 5 5 6 6

LT6 P ATS 48 ATV 31

LT6 P

1 2 3 4 5 6 7

Gateway LA9 P307, Tap-off cable VW3 P07 306 R10, Modbus splitter box LU9 GC3, Cable TSX CSA p00, Tap-link cable VW3 A8 306 Rpp, Tap-link cable VW3 A8 306 D30, Line end adapter VW3 A8 306 RC.

Description
562298

1 2 3 4 5 6

Gateway LA9 P307 comprises : 1 A SUB-D 9-way female connector for connection to the Profibus DP bus, 2 A line end adapter on the Profibus DP bus, 3 Gateway address coding on the Profibus DP bus, 4 Status signalling LED, 5 RJ 45 female connector for connection on the Modbus bus, 6 c 24 V power supply.

Software set-up
The gateway is configured using the standard software tools for the Profibus bus. For the Premium automation platform, use SYCON configurator software. The user's manual (.PDF) and the gateway description file (.GSD) are supplied on diskette with the gateway.

Characteristics, catalog numbers :page 205 20

Dimensions : page 205

204

Global Catalog. Refer to Statement of Scope on page 2.

Characteristics, catalog numbers, dimensions

Starters, drives and communication


Communication gateway LA9 P307

Characteristics
Environment Conforming to IEC 60664 Ambient air temperature Around the device Degree of protection Number of Modbus slaves which can be connected Connection on Modbus Profibus Supply Consumption Indication/diagnostics Services Command Monitoring Configuration and adjustment C Degree of pollution: 2 0...+ 50 IP 20 15 RJ 45 connector SUB-D 9-way female connector External supply, c 24 V 20 % 150 on c 24 V By LED 16 words 16 words By gateway mini messaging facility (PKW)

mA

Catalog numbers
Description
562299

For use with LT6 P ATS 48 ATV 31 For use with Screw terminal block - T-junction box TSX SCA 50 - Y-junction subscriber socket TSX SCA 62 SUB-D connector (to be ordered separately) - LT6 P (SUB-D 9 female)

Catalog number LA9 P307

Profibus DP/Modbus communication gateway Description RJ 45 cable with stripped wires

Weight kg 0.260

Length Catalog number m 3 VW3 A8 306 D30

Weight kg 0.150

LA9 P307
822713

RJ 45-RJ 45 cable

ATS 48 ATV 31 Modbus splitter box LU9 GC3 Profibus mid line Profibus line end

VW3 P07 306 R10

0.050

Connectors

490 NAD 911 04

490 NAD 911 03

490 NAD 911 03

Dimensions
LA9 P307

76,5

35

Presentation, description : page 204

Setting-up : page 204

93

Global Catalog. Refer to Statement of Scope on page 2.

205

The efficiency of Telemecanique branded solutions


Used in combination, Telemecanique products provide quality solutions, meeting all your Automation and Control applications requirements.

Operator dialog

Software tools Motion control

Networks & communication

Simple machines Altistart 01: 0.50 to 100 hp (0.37 to 75 kW) Altivar 11: 0.25 to 3 hp (0.18 to 2.2 kW) Altivar 31: 0.25 to 20 hp (0.18 to 15 kW)

Interfaces & I/O

Automation Motor control

Detection Mounting systems

Power supplies

A worldwide presence
Complex, high power machines Altivar 71: 0.5 to 700 hp (0.37 to 500 kW) Constantly available b More than 5 000 points of sale in 130 countries. b You can be sure to find the range of products that are right for you and which complies fully with the standards in the country where they are used. Technical assistance wherever you are b Our technicians are at your disposal to assist you in finding the optimum solution for your particular needs. b Schneider Electric provides you with all necessary technical assistance, throughout the world.

Pumping and ventilation machines Altistart 48: 4 to 1200 kW Altivar 58: 0.5 to 500 hp (0.37 to 315 kW)

Schneider Electric USA


2641 Sumner Blvd. Raleigh, NC 27616 1-888-SquareD (1-888-778-2733) www.us.Telemecanique.com

Simply Smart !
Catalog No. 8800CT0501 March 2005 Schneider Electric All Rights Reserved 8800CT0501 03/2005