Rapport 2 Bordj Cedria Charge Detaillee

The PVsyst simulation report for a grid-connected solar system in Borj Cedria, Tunisia, details a system power of 10.56 kWp with an annual energy production of 16,964.92 kWh and a performance ratio of 85.17%. The system is designed to meet daily household energy needs averaging 68 kWh/day, with a solar fraction of 27.17%. The report includes detailed parameters, user needs, and monthly energy balances, showcasing the system's efficiency and energy distribution.

Uploaded by

moez youssef
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views8 pages

Rapport 2 Bordj Cedria Charge Detaillee

The PVsyst simulation report for a grid-connected solar system in Borj Cedria, Tunisia, details a system power of 10.56 kWp with an annual energy production of 16,964.92 kWh and a performance ratio of 85.17%. The system is designed to meet daily household energy needs averaging 68 kWh/day, with a solar fraction of 27.17%. The report includes detailed parameters, user needs, and monthly energy balances, showcasing the system's efficiency and energy distribution.

Uploaded by

moez youssef
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Version 7.4.

PVsyst - Simulation report


Grid-Connected System

Project: habit bordj cedria charges detailles


Variant: Nouvelle variante de simulation
No 3D scene defined, no shadings
System power: 10.56 kWp
Borj Cedria - Tunisia

Author
Project: habit bordj cedria charges detailles
Variant: Nouvelle variante de simulation

PVsyst V7.4.0
VC0, Simulation date:
15/04/25 13:30
with v7.4.0

Project summary
Geographical Site Situation Project settings
Borj Cedria Latitude 36.71 °N Albedo 0.20
Tunisia Longitude 10.42 °E
Altitude 5m
Time zone UTC+1

Meteo data
Borj Cedria
NASA-SSE satellite data 1983-2005 - Synthétique

System summary
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation Near Shadings User's needs


Fixed plane No Shadings Daily household consumers
Tilt/Azimuth 30 / 20 ° Seasonal modulation
Average 68 kWh/Day

System information
PV Array Inverters
Nb. of modules 24 units Nb. of units 1 unit
Pnom total 10.56 kWp Pnom total 9.00 kWac
Pnom ratio 1.173

Results summary
Produced Energy 16964.92 kWh/year Specific production 1607 kWh/kWp/year Perf. Ratio PR 85.17 %
Used Energy 24813.69 kWh/year Solar Fraction SF 27.17 %

Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7
Single-line diagram 8

15/04/25 PVsyst Licensed to Page 2/8


Project: habit bordj cedria charges detailles
Variant: Nouvelle variante de simulation

PVsyst V7.4.0
VC0, Simulation date:
15/04/25 13:30
with v7.4.0

General parameters
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 30 / 20 ° Diffuse Perez, Meteonorm
Circumsolar separate

Horizon Near Shadings User's needs


Free Horizon No Shadings Daily household consumers
Seasonal modulation
Average 68 kWh/Day

PV Array Characteristics
PV module Inverter
Manufacturer Generic Manufacturer Generic
Model Mono 440 Wp Twin 144 half-cells bifacial Model 9 kWac inverter
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 440 Wp Unit Nom. Power 9.00 kWac
Number of PV modules 24 units Number of inverters 2 * MPPT 50% 1 unit
Nominal (STC) 10.56 kWp Total power 9.0 kWac
Modules 2 Strings x 12 In series Operating voltage 150-750 V
At operating cond. (50°C) Max. power (=>25°C) 10.00 kWac
Pmpp 9.59 kWp Pnom ratio (DC:AC) 1.17
U mpp 450 V No power sharing between MPPTs
I mpp 21 A

Total PV power Total inverter power


Nominal (STC) 11 kWp Total power 9 kWac
Total 24 modules Number of inverters 1 unit
Module area 53.8 m² Pnom ratio 1.17
Cell area 47.7 m²

Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 354 mΩ Loss Fraction -0.4 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module mismatch losses


Loss Fraction 2.0 % at MPP

IAM loss factor


Incidence effect (IAM): Fresnel, AR coating, n(glass)=1.526, n(AR)=1.290

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.999 0.987 0.962 0.892 0.816 0.681 0.440 0.000

15/04/25 PVsyst Licensed to Page 3/8


Project: habit bordj cedria charges detailles
Variant: Nouvelle variante de simulation

PVsyst V7.4.0
VC0, Simulation date:
15/04/25 13:30
with v7.4.0

Detailed User's needs


Daily household consumers, Seasonal modulation, average = 68 kWh/day
Summer (Jun-Aug) Autumn (Sep-Nov)

Nb. Power Use Energy Nb. Power Use Energy


W Hour/day Wh/day W Hour/day Wh/day
Lampes (LED ou fluo) 20 20/lamp 6.0 2400 Lampes (LED ou fluo) 20 20/lamp 6.0 2400
TV / PC / Mobile 3 100/app 5.0 1500 TV / PC / Mobile 3 100/app 5.0 1500
Appareils domestiques 2 1500/app 2.0 6000 Appareils domestiques 2 1500/app 2.0 6000
Frigo / Congélateur 2 24 6000 Frigo / Congélateur 2 24 6000
Machines à laver linge/vaisselle 2 2 6 Machines à laver linge/vaisselle 2 2 6
climatiseur 8 1500 tot 6.0 72000 chauffage electrique 2 2000 tot 2.0 8000
Consomm. de veille 24.0 24000 Consomm. de veille 24.0 24000
Total daily energy 111906 Total daily energy 47906

Winter (Dec-Feb) Spring (Mar-May)

Nb. Power Use Energy Nb. Power Use Energy


W Hour/day Wh/day W Hour/day Wh/day
Lampes (LED ou fluo) 20 20/lamp 6.0 2400 Lampes (LED ou fluo) 20 20/lamp 6.0 2400
TV / PC / Mobile 3 100/app 5.0 1500 TV / PC / Mobile 3 100/app 5.0 1500
Appareils domestiques 2 1500/app 2.0 6000 Appareils domestiques 2 1500/app 2.0 6000
Frigo / Congélateur 2 24 6000 Frigo / Congélateur 2 24 6000
Machines à laver linge/vaisselle 2 2 6 Machines à laver linge/vaisselle 2 2 6
chauffage electrique 2 2000 tot 6.0 24000 chauffage electrique 2 2000 tot 2.0 8000
Consomm. de veille 24.0 24000 Consomm. de veille 24.0 24000
Total daily energy 63906 Total daily energy 47906

Hourly distribution

15/04/25 PVsyst Licensed to Page 4/8


Project: habit bordj cedria charges detailles
Variant: Nouvelle variante de simulation

PVsyst V7.4.0
VC0, Simulation date:
15/04/25 13:30
with v7.4.0

Main results
System Production
Produced Energy 16964.92 kWh/year Specific production 1607 kWh/kWp/year
Used Energy 24813.69 kWh/year Perf. Ratio PR 85.17 %
Solar Fraction SF 27.17 %

Normalized productions (per installed kWp) Performance Ratio PR

Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_User E_Solar E_Grid EFrGrid
kWh/m² kWh/m² °C kWh/m² kWh/m² kWh kWh kWh kWh kWh
January 71.3 28.52 12.72 109.2 107.1 1051 1981 404.4 628 1577
February 89.6 32.76 12.77 123.4 121.3 1174 1789 391.7 761 1398
March 130.8 48.36 14.37 159.4 156.4 1501 1485 489.5 984 996
April 156.6 59.40 16.65 169.6 166.3 1583 1437 513.3 1040 924
May 196.5 66.96 20.65 194.0 189.7 1771 1485 562.4 1177 923
June 208.2 65.70 24.73 196.3 191.7 1751 3357 855.5 862 2502
July 226.6 59.83 27.46 216.3 211.3 1893 3469 898.5 959 2571
August 195.0 57.04 27.84 202.8 198.6 1780 3469 858.1 890 2611
September 140.7 50.40 24.84 162.8 159.6 1469 1437 504.5 938 933
October 104.5 41.23 22.11 134.8 132.3 1240 1485 461.9 755 1023
November 74.1 29.70 17.85 111.9 109.8 1055 1437 395.0 640 1042
December 64.8 25.73 14.33 105.7 103.9 1015 1981 407.8 588 1573
Year 1658.7 565.63 19.74 1886.2 1847.9 17284 24814 6742.7 10222 18071

Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_User Energy supplied to the user
T_Amb Ambient Temperature E_Solar Energy from the sun
GlobInc Global incident in coll. plane E_Grid Energy injected into grid
GlobEff Effective Global, corr. for IAM and shadings EFrGrid Energy from the grid

15/04/25 PVsyst Licensed to Page 5/8


Project: habit bordj cedria charges detailles
Variant: Nouvelle variante de simulation

PVsyst V7.4.0
VC0, Simulation date:
15/04/25 13:30
with v7.4.0

Loss diagram
1659 kWh/m² Global horizontal irradiation
+13.7% Global incident in coll. plane

-2.03% IAM factor on global

1848 kWh/m² * 54 m² coll. Effective irradiation on collectors

efficiency at STC = 19.66% PV conversion

19544 kWh Array nominal energy (at STC effic.)


-0.59% PV loss due to irradiance level

-8.59% PV loss due to temperature

+0.37% Module quality loss

-2.00% Module array mismatch loss

-1.07% Ohmic wiring loss


17284 kWh Array virtual energy at MPP
-1.84% Inverter Loss during operation (efficiency)
0.00% Inverter Loss over nominal inv. power
0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
-0.01% Inverter Loss due to power threshold
grid
0.00% Inverter Loss due to voltage threshold
consumption
16965 kWh Available Energy at Inverter Output

18071 6743 10222 kWh Dispatch: user and grid reinjection

to user to user to grid


from grid from solar

15/04/25 PVsyst Licensed to Page 6/8


Project: habit bordj cedria charges detailles
Variant: Nouvelle variante de simulation

PVsyst V7.4.0
VC0, Simulation date:
15/04/25 13:30
with v7.4.0

Predef. graphs
Diagramme d'entrée/sortie journalier

Distribution de la puissance de sortie système

15/04/25 PVsyst Licensed to Page 7/8


PVsyst V7.4.0
VC0, Simulation date:
15/04/25 13:30
with v7.4.0

You might also like