0% found this document useful (0 votes)
18 views24 pages

Clippard Proportional Valves Brochure

The document details various series of proportional valves offered by Clippard, including the EVP, DVP, and PV series, highlighting their features such as precision control, low power consumption, and high flow rates. Each series is designed for specific applications, with capabilities for air or gas flow control and customizable performance. The document also includes technical specifications, ordering information, and guidance on selecting the appropriate valve for different operational needs.

Uploaded by

Manish Mandaviya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views24 pages

Clippard Proportional Valves Brochure

The document details various series of proportional valves offered by Clippard, including the EVP, DVP, and PV series, highlighting their features such as precision control, low power consumption, and high flow rates. Each series is designed for specific applications, with capabilities for air or gas flow control and customizable performance. The document also includes technical specifications, ordering information, and guidance on selecting the appropriate valve for different operational needs.

Uploaded by

Manish Mandaviya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

PROPORTIONAL

10 & 15 MM ELECTRONIC
VALVES VALVES
Proportional Valves
EVP Series DVP Series PV Series 8 mm Micro
Proportional Valve Proportional Valve Proportional Valve

Precision-built utilizing Clippard’s The DVP series offers an extremely The tiny PV series provides precise,
renowned Spider Technology high cycle life, fast response, linear linear control for accurate dosing
with the additional capability for flow gain, low power consumption, and flow regulation in critical
proportional control. The EVP and flows over 60 l/min. The DVP applications. With low power
provides air or gas flow control and provides air or gas flow control and consumption, they offer excellent
varies the output flow based on varies the output flow based on the energy efficiency while maintaining
the current input to the solenoid. current input to the solenoid. quiet operation and minimal
Controllability and overall value are vibration. Their versatile design
the main features of this series. The makes them suitable for a wide
consistent gain of the EVP provides range of medical, diagnostic, and
a high degree of control. industrial applications.

p. 4 p. 8 p. 14

3 voltage coils Higher flow (over 60 l/min) Ideal for compact assemblies

≤10% hysteresis Fast response Elminiates downstream pulsations

~±10% of given flow target Spider Technology for long life Low current power

Fast response Low to no noise

Spider Technology for long life Highly customizable performance

2 Proportional Valves
SCPV Series Eclipse Proportional
Stepper Needle Valve Isolation Valve

Utilizing the industry’s most robust The patented, stepper-controlled


and powerful linear actuator, the Eclipse proportional isolation valve
SCPV series stepper-controlled leads the industry in performance
proportional valve is ideal for and durability. This valve is ideal in
critical medical, analytical, and critical applications for liquid and
industrial automation applications gas delivery, medical, analytical and
that require high resolution, high industrial automation requiring
flow, low hysteresis, and variable ultra fine resolution and excellent
control of inert gases. repeatability. In addition, the
unique design allows for custom
flow profiles.

p. 16 p. 18

High accuracy stepper-driven needle valve Ceramic sliding seal

Fully customizable design Liquid capable

Very low hysteresis Zero dead volume (fully flushable)

“Set it and forget it” control 0.0009 in3 (0.0154 cm3)

0.001” (0.03 mm) step resolution Unique, patented design

Ultra-fine resolution

877-245-6247 | clippard.com 3
EVP PROPORTIONAL VALVES

Coil Resistance 13.5, 54, 218 Ω @ 72°F (22°C)


Connection Square pin, terminal spades,
or 18” (45.7 cm) wire leads
Current 0 to 0.370 A, 0 to 0.185 A, 0 to 0.092 A
Driver EVPD (optional)
Filtration 40 micron filter (recommended)
Flow Range Up to 22 l/min
Function 2-way normally-closed proportional
Material, Body Nickel plated brass
Material, Seals Nitrile, FKM, or EPDM
Material, Seat Stainless steel
The EVP series proportional control valves combine the
Material, Wetted ENP brass, ENP steel, stainless steel
features of the existing EV series valve—long life, low power,
and Clippard’s reputation for high quality components— Max. Flow ±10% of target flow
with the additional capability for proportional control. The Max. Hysteresis ≤10% of full current
EVP series valve provides air or gas flow control and varies
Max. psig 100 psig (7 bar)
the output flow based on the current input to the solenoid.
Medium Clean, dry air or inert gases
Controllability and overall value are the main features Mount In-line threaded ports or manifold
of the EVP proportional valve series. The consistent gain
Number of Ports 2
of this valve provides a high degree of control for many
applications. The valve may be controlled using DC current, Operating Pressure Vac. to 100 psig (0.3 to 7 bar)
open or closed-loop control, and even PWM (pulse width Operating Temp. Range 32 to 120˚F (0 to 48˚C)
modulation) to cover a broad range of applications. Orifice 0.009”, 0.013”, 0.025”, 0.040”, 0.060”
(0.23, 0.33, 0.64, 1.00, 1.52 mm)
Typical Performance
Port, Inlet #10-32 female or manifold stud
25
Port, Outlet #10-32 female or manifold outlet hole
54 Ohm Coil Power Requirement 1.9 watts @ 72°F (22˚C); 2.3 watts max.
20 0.025” (0.6 mm) Orifice
100 psig (7 Bar) Voltage 5, 10, or 20 VDC nominal
73˚F (23˚C)
15 Wattage 1.9 watts @ 72˚F (22˚C), 2.3 watts max.
Flow (l/min)

More Details clippard.com/link/evp-series


10

0
0 0.02 0.04 0.06 0.08 0.10 0.12 0.14 0.16 0.18 0.20
Input Current (amps)
The above flow curve is a typical calibration record for the EVP. All proportional
valves have a stored calibration data sheet readily available upon request.

4 EVP Series
Inline Mount Manifold Mount Manifolds
Pilot Manifold #10-32 Inlet,
15490-1
1/8” NPT Outlet
2-Way
Single Supply 1/8” NPT Inlet,
15490-2
#10-32 Outlet 1
2
1.560” 1.570”
(39.6) (39.9) Dual Supply 1/8” NPT Inlet,
15490-3
#10-32 Outlet
1 Inlet Outlet 2 1 Inlet
Side-Ported #10-32 Inlet,
15491-1
0.151” (3.8) 1/8” NPT Outlet
0.870” (22.1) dia.
Side-Ported 1/8” NPT (R1/8)
15491-2
0.870” (22.1) dia. Inlet, #10-32 Outlet
Inlet 1 Single-Station 1/8” NPT Inlet,
2 Outlet 15490-5
0.500” 1/8” NPT Outlet
(12.7)
15481-2 Single-Sided 2-Station
#6-32 thd. mtg. holes
0.215” (5.5)
15481-4 Single-Sided 4-Station
15481-6 Single-Sided 6-Station
15482-8 Double-Sided 8-Station
15482-12 Double-Sided 12-Station

• Flow proportional to input current


Dimensions shown are in inches (millimeters listed in parentheses).
Visit clippard.com for more detailed 2D and 3D drawings. • Fast response and long life
Myriad Pro, 10 pt & 7pt
Black, 0.5 stroke

ORDERING INFORMATION

E ❑ - P ❑ - ❑ - ❑ _ _ - ❑
Electrical Connection
C Connector
T Terminal Spades Voltage Seal
Mounting
V Wire Leads 05 0 to 5 VDC (blank) Nitrile
(blank) Base Mount 10 0 to 10 VDC E EPDM1
M Manifold Mount 20 0 to 20 VDC V FKM1

Orifice* Maximum Pressure (5 psig to 100 psig)


09 0.009” (0.23) dia., 2.7 l/min ±10%, max. 100 psig (7 bar) 00 In increments of 5, from 05 to 95
13 0.013” (0.33) dia., 6.7 l/min ±10%, max. 100 psig (7 bar) A0 100 psig
25 0.025” (0.64) dia., 22.0 l/min ±10%, max. 100 psig (7 bar)
40 0.040” (1.02) dia., 18.7 l/min ±10%, max. 50 psig (3.4 bar)
60 0.060” (1.52) dia.,14.0 l/min ±10%, max. 25 psig (1.7 bar) 1
Min. order quantity required for EPDM or FKM seals.

Please Note: Not all possible configurations are valid.


Consult the online configurator at clippard.com.

Example Part Number: For more info, scan the


EC-P-05-0925 QR code or visit
clippard.com/link/evp-series

TDS EVP-01, Rev. 081424 (2/4) 877-245-6247 | clippard.com 5


A Close-Up of the EVP Series

Low Power Coil


Uses only 1.9 watts at
the rated voltage

Seal Material
Nitrile, FKM, EPDM, and
others available

Adjustment Ring
May be loosened for positioning
to orient connections
(do not remove)

Precision-Built with Clippard


Standard Orifices Spider Technology
Unique design utilizes only a single
0.0009” (0.2 mm)
moving part for low friction and long life
0.013” (0.3 mm)
0.025” (0.6 mm)
0.040” (1.0 mm)
0.060” (1.5 mm)

Variety of Mounting Options

6 EVP Series
How to Select Your EVP Proportional Valve
When choosing your valve, 1 CONTROL SIGNAL
there are many variables to
Voltage Range Input Current Range Coil Resistance Max. Voltage Required
consider. To select the best
valve for your application, 0 to 5 VDC @ 72˚F (22˚C) 0 to 0.370A 13.5 ohms @ 72˚F (22˚C) 6.2 VDC
focus on: 0 to 10 VDC @ 72˚F (22˚C) 0 to 0.185A 54 ohms @ 72˚F (22˚C) 12.4 VDC
0 to 20 VDC @ 72˚F (22˚C) 0 to 0.092A 218 ohms @ 72˚F (22˚C) 24.8 VDC
1 Control Signal Note: Do not exceed input current range
2 Valve Orifice
3 Operating Pressure 2 VALVE ORIFICE (Maximum Working Pressure)

Orifice Diameter Rated Pressure Flow at Max. Current (±10%)


Please Note: It is important to 0.009” (0.23 mm) 100 psig (7 bar) 2.7 l/min @ 100 psig (7 bar)
specify and use a calibrated valve that
matches your application. Be sure 0.013” (0.33 mm) 100 psig (7 bar) 6.7 l/min @ 100 psig (7 bar)
to use a valve set to your operating 0.025” (0.64 mm) 100 psig (7 bar) 22.0 l/min @ 100 psig (7 bar)
pressure. Otherwise, the required 0.040” (1.02 mm) 50 psig (3.4 bar) 18.7 l/min @ 50 psig (3.4 bar)
power for opening the valve will be 0.060” (1.52 mm) 25 psig (1.7 bar) 14.0 l/min @ 25 psig (1.7 bar)
high and the resolution to set your
flow proportional will be poor. Note: Maximum flow is measured at maximum pressure

3 Maximum
OPERATING PRESSURE
Flow - Maximum
vs. Operating PressureFlow vs. Operating Pressure

25.0
0.025”
Orifice
0.040”
Flow (±10%) at Maximum Current (l/min)

20.0 Orifice

0.060”
15.0
Orifice

10.0
0.013”
Orifice

5.0
0.009”
Orifice

0.0
0 10 20 30 40 50 60 70 80 90 100
(0.7) (1.4) (2.1) (2.8) (3.4) (4.1) (4.8) (5.5) (6.2) (6.9)

Maximum Operating Pressure - psig (bar)


To determine the correct orifice required, locate the colored line immediately above the flow/pressure intersection.
Example: 9 slpm required at 45 psig inlet. This example leads to a “-2545” valve (0.025” nozzle, 45 psig).

TDS EVP-01, Rev. 081424 (4/4) 877-245-6247 | clippard.com 7


DVP PROPORTIONAL VALVES
REACH
COMPLIANT

Coil Resistance 52.6, 210.5 Ω @ 72°F (22°C)


Connection Terminal spades or 18” (45.7 cm) wire leads
Current 0 to 0.190 A, 0 to 0.095 A
Driver EVPD (optional)
Filtration 40 micron filter (recommended)
Function 2-way normally-closed proportional
Material, Body Stainless steel
Material, Seals FKM, nitrile, EPDM, or silicone
Material, Seat Stainless steel
Material, Wetted 304 stainless steel, PPS

Clippard’s DVP series proportional solenoid valves are Max. Flow +10%, -0%
precision-built 2-way control valves. With its solid, compact Medium Air or compatible gases
dsign, long life, and exceptionally high flow rates, these Mount Manifold, #10-32 male stud
valves are suitable for a wide variety of applications across
Number of Ports 2
many different industries.
Operating Pressure Vac. to 100 psig (7 bar)
The DVP valve provides air or gas flow control and varies
Operating Temp. Range 32 to 120˚F (0 to 49˚C)
the output flow based on the current input to the solenoid.
The valve’s consistent gain provides a high degree of Port, Inlet Manifold stud
control. It may be controlled using DC current, open or Port, Outlet Manifold outlet hole
closed-loop control, and even pulse width modulation Voltage 10 or 20 VDC nominal
(PWM) to cover a large range of applications.
Wattage 1.9 watts @ 72˚F (22˚C), 2.5 watts max.
More Details clippard.com/link/dvp-series
Typical Performance
50
45 Based on
40 DV-PM-10-455027-V

35
30
Flow (l/min)

25
20
15
10
5
0
0.00 0.02 0.04 0.06 0.08 0.10 0.12 0.14 0.16 0.18 0.20
Input Current (Amps)

The above flow curve is a typical calibration record for the DVP. All proportional
valves have a stored calibration data sheet readily available upon request.

8 DVP Series
Spade Terminals Manifolds
15490-5 Single-Station, ENP Brass
0.55” (14.0) 2-Way
2-Station, Black Anodized
0.26” (6.6) 15781-2
Aluminum, 1/8” NPT
1 Anodized 2
4-Station, Black
15781-4
Aluminum, 1/8” NPT

1.83”
6-Station, Black Anodized
(46.5)
15481-6
Aluminum, 1/8” NPT
1.93”
(49.0)
0.739”
(18.8) Dimensions shown are in inches
dia.
(millimeters listed in parentheses).
0.450”
#10-32 (11.4)
0.16” dia. Visit clippard.com for more detailed
(4.1)
2D and 3D drawings.

Wire Leads

18.00” (457.2)

0.28”
(7.1)

• Extremely low hysteresis

0.74”
• Low heat rise / low power
(18.8) 0.22”
dia. (5.6) • Flow proportional to input current
1.92” 2.03”
(48.8) (51.6) • Robust stainless steel spring, base, and housing
• Industry standard for leak-free operation

#10-32 Outlet
Inle t

ORDERING INFORMATION

D ❑ - P M - ❑ - ❑ - ❑ - ❑
Seals
V FKM (standard)
Voltage Operating Pressure (blank) Nitrile
10 10 VDC E EPDM1
In increments of 1, S Silicone1
Electrical Connection 20 20 VDC from 005 to 100
T Spade Terminals Flow 5 psig (0.4 Bar) to 1
Min. order quantity required
V Wire Leads (Axial) 100 psig (6.9 Bar) for EPDM or silicone seals
In increments of 1, from 010 to 678
(1.0 l/min to 67.8 l/min) Example: 040 (40 psig, 2.8 bar)

Example: 300 (300 l/min)

Example Part Number: For more info, scan the


DT-PM-10-300-040-V QR code or visit
clippard.com/link/dvp-series

TDS DVP-01, Rev. 120424 (2/4) 877-245-6247 | clippard.com 9


A Close-Up of the DVP Series

Wire Leads or
Spade Terminal Connectors

Stainless Steel
Low Power Coil
Core, housing, and base
Uses only 1.9 watts at
the rated voltage

Stainless Steel Plunger


Spider Assembly
with overmolded seal and bumper

Poppet Seal

#10-32 or Cartridge

10 DVP Series
How to Select Your DVP Proportional Valve
Proportional flow is achieved by varying the current input To select your valve, reference the flow chart and list your
to the valve. It is crucial to specify and use a calibrated valve operating pressure in a 3-digit format (065 = 65 psig).
that matches your application. To ensure you have a valve Next, specify your desired maximum flow rate for your
that will perform well for your specific requirements, be sure pressure (500 = 50.0 l/min). Accurately specify your nominal
to use a valve set to your operating pressure. operating pressure and flow to ensure the best performance
and resolution for your application.
The flow capabilities shown below in green are standard
configurable options. The flow capabilities shown in blue For nominal operating pressures under 5 psig, use a 005
are available as a special custom option. Contact Clippard designator for pressure. For vacuum applications, use the
for more details. positive pressure equivalent and reverse the ports.

When choosing your valve, 1 CONTROL SIGNAL


there are many variables to
Voltage Range Input Current Range Coil Resistance Max. Voltage Required
consider. To select the best
valve for your application, 0 to 10 VDC @ 72˚F 0 to 0.190A 52.6 ohms @ 72˚F 13 VDC
focus on: 0 to 20 VDC @ 72˚F 0 to 0.095A 210.5 ohms @ 72˚F 26 VDC
Note: Do not exceed input current range
1 Control Signal
2 OPERATING PRESSURE - Flow vs. Operating Pressure
2 Operating Pressure
DVP Flow Capabilities
100
Please Note: It is important to 90
specify and use a calibrated valve that 80 Standard
matches your application. Be sure
70 Custom
to use a valve set to your operating
Flow (l/min)

pressure. Otherwise, the required 60


power for opening the valve will be 50
high and the resolution to set your
40
flow proportional will be poor.
30
20
10
0
0 10 20 30 40 50 60 70 80 90 100 110
(0.7) (1.4) (2.1) (2.8) (3.4) (4.1) (4.8) (5.5) (6.2) (6.9) (7.6)

Operating Pressure - psig (bar)

TDS DVP-01, Rev. 120424 (4/4) 877-245-6247 | clippard.com 11


EVP / DVP DRIVER

Adjustment Min. drive current, max. drive current,


command deadband
Command Set-Point Selectable: 0 to 5 VDC, 0 to 10 VDC, 0 to 20 mA,
Signal Type 4 to 20 mA, PWM @ ≥ 2 kHz duty cycle
Connection Screw terminals or DIN connector
Input Impedance 200 kΩ
LED Indicators Power, activity, status, and faults
Mount Mounting holes or DIN rail
Operating Temp. Range 0 to 155˚F (-18˚ to 68˚C)
Output 0 to 400 mA (selectable range)
Power Requirement 7 to 28 VDC @5 watt
More Details clippard.com/link/evpd-driver

The EVPD proportional valve driver fast-tracks valve control The tuning adjustments on the EVPD allow the user to
applications. This product is ideal for laboratories and adjust the command signal needed to start opening the
OEM product development and can be customized to fit valve, adjust the opening current to the valve, and limit the
OEM applications including control parameters. The EVPD maximum current to the valve to restrict the valve maximum
produces driver current for Clippard’s EVP or DVP series opening and prevent current beyond the valve solenoid’s
valves proportional to input control signals. rating. The settings are used by the valve management
software in the microcontroller along with driver current
feedback to calculate command instructions to the digital
• Plug-and-play interface between Clippard’s EVP PWM controller.
and DVP series valves and PLCs or other controls
The resulting change to valve performance is shown in the
• Linearized valve response right “out of the box”
Effect on Valve Flow chart for a typical EVP valve (10 VDC coil,
• Three selectable valve output ranges 0.06” orifice, 25 psig max).
• Five signal inputs to choose from
• Easy integration with existing machine controls
• User-adjustable parameters Power Requirements

• Automatic temperature compensation to maintain Power input requirements are specified as supply voltage
constant current ranges for each EVP or DVP valve. Supplying voltages
• Two configuration options: stand-alone PCB outside of these ranges may result in valve malfunctioning.
or enclosed in housing Power requirements are determined by the valve voltage
• Compact size specification.

EVP Input Voltage EVPD Max.


Valve Type Range Output

0 to 5 VDC 7 to 12 VDC 400 mA


0 to 10 VDC 12 to 28 VDC 200 mA
0 to 20 VDC 14 to 28 VDC 100 mA

12 EVP Driver
EVPD-2 EVPD-1

1.8” (45.7)
Dimensions shown are in inches
Power LED Status Indicator LED (millimeters listed in parentheses).

Visit clippard.com for more detailed


2D and 3D drawings.

2.2” Command Threshold


(55.9)
Current Min

Current Max

Power (7-28 VDC) Current Command


Common (GND) Voltage Command
Valve + Valve -

Effect on Valve Flow


100

90

80
Percent of Full Scale Flow

70

60

50  Driver
 Direct DC Current
40

30

20

10

0
0 10 20 30 40 50 60 70 80 90 100
Percent of Full Scale Input Signal

ORDERING INFORMATION

E V P D - ❑
EVP Driver
1 Driver Assembly in Enclosure
2 Driver Board
2DIN DIN Rail Mounting Clip

Example Part Number: For more info, scan the


EVPD-1 QR code or visit
clippard.com/link/evpd-driver

TDS EVPD-01, Rev. 041524 (2/2) 877-245-6247 | clippard.com 13


PV SERIES PROPORTIONAL VALVE
REACH
COMPLIANT

Connection 3.15” (80 mm) wire leads


Current Range 0 to 70 mA
Cycle Life 100 million
Filtration 10 micron
Function 2-way normally-closed proportional
Hysteresis < 10% of full current
Leak Rate 1.0 sccm
Actual size Material, Wetted Stainless steel, FKM/FFKM
Max. Flow 0.012” (0.3 mm) Orifice:
7.3 ± 0.7 l/min @ 145 psig (10 bar)
0.020” (0.5 mm) Orifice:
7.0 ± 1.0 l/min @ 87 psig (6 bar)
These 8 mm proportional direct-acting valves provide Medium Air, inert gases
precise, linear control for accurate dosing and flow
Mount Cartridge
regulation in critical applications. With low power
consumption, they offer excellent energy efficiency Nominal Coil Resistance 308 Ω @ 68˚F (20˚C)
while maintaining quiet operation and minimal vibration. Number of Ports 2
Their versatile design makes them suitable for a wide range Operating Pressure 0.012” (0.3 mm) Orifice: 0 to 145 psig (10 bar)
of medical, diagnostic, and industrial applications. 0.020” (0.5 mm) Orifice: 0 to 87 psig (6 bar)
Operating Temp. Range 41 to 122˚F (5 to 50˚C)
Standard products offered will fit the needs of most Orifice 0.012” (0.3 mm), 0.020” (0.5 mm)
applications, however this series can be fully customized Wattage 1.5 watts @ 68˚F (20˚C); 2.2 watts max.
according to the user’s unique requirements. Consult
More Details clippard.com/link/pv8
Clippard with your specific application.

• Ideal for compact assemblies


• Eliminates downstream pulsations
• Smooth proportional delivery
• Low current power / low to no noise
• Exceptional variability of flow vs. command current
• Tiny package with a robust design
• Highly customizable performance

14 PV Series
Dimensions shown are in inches (millimeters listed in parentheses).
Visit clippard.com for more detailed 2D and 3D drawings.

Manifold
0.327” (8.3) +0.005
-0.000 dia.

30˚ typ. 0.99”


0.315” (8.0) dia. (25.1)

0.695”
(17.7) Clearance
max. for M3 or
0.790” #4 Screw
(20.1) 0.860”
+0.004 (21.8)
-0.000
0.830” 1.000”
(21.1) (25.4)

0.958”
(24.3) 1.25”
(31.8)
0.303” (7.7) dia.

0.453”
(11.5)

0.177” Inlet
0.230” (5.9) +0.002
-0.000 dia. (4.5)
0.50”
(12.7)
0.250” (6.3) +0.005
-0.000
Outlet
0.228” (5.8) dia.
0.317” (8.1) +0.002
-0.000 dia.

Typical Performance for 0.012” Orifice (Air) Typical Performance for 0.020” Orifice (Air)
8 8

7 7

6  30 psig (2 Bar) 6  15 psig (1 Bar)


 60 psig (4 Bar)  30 psig (2 Bar)
5 5
Flow (l/min)

Flow (l/min)

 100 psig (7 Bar)  60 psig (4 Bar)

 145 psig (10 Bar)  87 psig (6 Bar)


4 4

3 3

2 2

1 1

0 0
20 25 30 35 40 45 50 55 60 65 70 20 25 30 35 40 45 50 55 60 65 70
Input Current (Milliamps) Input Current (Milliamps)

ORDERING INFORMATION

P V 8 - ❑
Pressure Range
3 0.012" (0.3 mm) orifice—0 to 145 psig (10 bar)
5 0.020" (0.5 mm) orifice—0 to 87 psig (6 bar)
ACCESSORIES
SPM-01* Single-station manifold, #10-32
Example Part Number: For more info, scan the
M-SPM-01* Single-station manifold, M5 QR code or visit
PV8-3
*Also available in stainless steel (add -SS to part number) clippard.com/link/pv8

TDS PV8-02, Rev. 121024 (2/2) 877-245-6247 | clippard.com 15


SCPV NEEDLE VALVES

Connection Connector / wiring harness


Driver Bipolar chopper drive required
Flow Range Up to 280 l/min
Flow Resolution 0.7 l/min per step
Linearity <2.5% of full scale
Material, Wetted Stainless steel, aluminum, brass, acetal, and FKM
Max. Hysteresis <2%
Max. psig 100 psig
Medium Air or compatible gases
Mount In-line, manifold, or cartridge

Utilizing the industry’s most robust and powerful linear Needle 3.5˚
actuator, the SCPV series high flow stepper-controlled Number of Ports 2
proportional valves outperform the competition in Logic Input Voltage 3.3V or 5V jumper selectable
performance and durability. These vales are ideal in critical
Operating Pressure Vac. to 100 psig (7 bar)
applications such as gas delivery, medical, analytical, and
industrial automation requiring high resolution, high flow, Operating Temp. Range 32 to 184˚F (0 to 84˚C)
and low hysteresis. In addition, the unique design allows Operating Voltage 7 to 35 VDC
for custom flow profiles when required. Port, Inlet 1/8” NPT, manifold, or cartridge
Positioning a 3.5˚ needle through a 0.152” (3.9 mm) orifice Port, Outlet 1/8” NPT, manifold, or cartridge
in 0.001” (0.03 mm) step increments provides for very linear Position Resolution 0.001” (0.03 mm) per step
and repeatable flow control within your application process.
Repeatability <0.5% of full scale
Standard models, inline, cartridge, and manifold mounts are
ready to go for control of air and other inert gases. Response Time 0.95 secs fully-open to fully-closed
Wattage 3.85 watts nominal (only during adjustment—
zero power consumption to maintain position)
Flow Rate (SCPV-1-3 @ 100 psig) More Details clippard.com/link/scpv-series
400

350
Standard HIGHLY CUSTOMIZABLE FOR OEM APPLICATIONS
300 Custom
• Flow profiles up to 5,800 l/min
250 • High flow at low pressure
Flow (l/min)

200 • Materials such as PEEK or stainless steel


• Special seal materials such as FFKM and others
150
• Applications for control of water
100 • Applications that provide zero leak shutoff
• Changing the motor to accommodate an encoder
50
• Providing specific testing procedures
0
0 100 200 300 400 Contact Clippard to discuss what changes can be made to
Steps best fit your application requirements.

16 SCPV Series
Inline Mount Cartridge Mount Manifold Mount

Dimensions shown are in inches 0.875”


1.125” (millimeters listed in parentheses). (22.2)
(28.6)

Visit clippard.com for more detailed 0.875”


(22.2)
1.311”
(33.3)
2D and 3D drawings.
#6-32 thd.
#6-32 Mtg. Screws

3.699”
(94.0) 0.250”
(6.4) dia.
Mtg. Holes for 2.237” Outlet
#6 Socket Head (56.8)
Cap Screw 0.250”
1/8 NPT (6.4) dia.
2.211” Outlet 3.558”
(56.2) Inlet (90.4)
1.000” 2.070
(25.4) (52.6)

0.736” 0.945”
0.525” (18.7)
(13.3) (24.0)
1.250”
0.725” (31.8) Outlet
(18.4) 0.725”
0.172” (18.4)
(4.4)
Inlet #6-32 thd.
0.170” (4.3) dia.
thru Mtg. Holes 0.265” (6.7)

1/8 NPT Inlet

Acetal seat Stepper-controlled • <2% hysteresis


linear actuator with • Excellent linearity, <2.5% of full-scale
Customizable acme lead screw
stainless steel needle • 2 ms reaction time
• Millions of cycles
Anodized
aluminum body 1/8” NPT inlet & • Holds position for power savings
outlet ports (SCPV-1-3) or at a loss of power
Brass housing
and internals

ORDERING INFORMATION

❑ S C P V - 1 - ❑ ❑
Unit Mounting Style Seat
(blank) Imperial 3 Inline Version (blank) Acetal
M- Metric 3M Manifold Mount -R FKM
3C Cartridge Style

Example Part Number: For more info, scan the


SCPV-1-3M QR code or visit
clippard.com/link/scpv-series

TDS SCPV-01, Rev. 120424 (2/2) 877-245-6247 | clippard.com 17


ECLIPSE PROPORTIONAL ISOLATION VALVE

Current 0.49A per phase


Cycle Life Typically >1 million
Driver Bipolar chopper drive required
Flow Range Air: 0 to 7 l/min
Water: 0 to 190 ml/min
-0 / +10% @ 30 psig (2 bar)
Flow Resolution Air: 0.000487 l/min (487.5 µl) @ 30 psig (2 bar)
Water: 0.0002 l/min (200 µl) @ 30 psig (2 bar)
Linearity <4% of full-scale
Material, Body Ceramic
Material, Seals FKM standard, EPDM and others available
The Eclipse is a proportional isolation valve like no other.
Material, Wetted Ceramic (others depending on porting option)
Utilizing patented slide technology, it achieves exceptional
proportional flow resolution that far exceeds the Max. Flow Air: 0 to 7 l/min -0 /+10%
Water: 0 to 190 ml/min -0 /+10%
competition. Designed for precision, its flow path is fully
@ 30 psig (2 bar)
flushable and composed entirely of inert ceramic, ensuring
compatibility with a wide range of media. In addition, the Max. psig 30 psig (2 bar)
Eclipse features a unique soft start capability that gradually Medium Liquids and gases
introduces media at a controlled ramp rate to prevent Mount Manifold or flat bottom (ZDVF)
damage or turbulence.
Number of Ports 2
Utilizing a robust and powerful miniature linear actuator, Operating Pressure Vac. to 30 psig (2 bar)
the Eclipse is stepper-controlled, micro-stepping capable, Operating Temp. Range 32 to 180˚F (0 to 82˚C)
encoder-ready, and its unique design allows for custom flow
Port, Exhaust None
profiles.
Port, Inlet #10-32, Manifold or ZDVF (zero dead volume fitting)
For applications that demand exceptional liquid and gas
Port, Outlet #10-32, Manifold or ZDVF (zero dead volume fitting)
control, Clippard’s Eclipse offers outstanding precision and
unrivaled proportional flow resolution. Position Resolution 0.00006” (0.0015 mm)
Power Requirement 20 VDC supply to motor @ 30 psig (2 bar)
Proof Pressure 50 psig (3.4 bar)
• Leak free (<0.05 sccm typical)
Response Time <2 ms
• Unrivaled resolution
Wattage 2.5 watts nominal (only during adjustment,
• Inert flow path (all wetted areas ceramic) zero power consumption to maintain position)
• Soft start prevents damage or turbulence More Details clippard.com/link/eclipse-valve
• Zero dead volume (fully flushable, <0.0009 in3)
*This product is highly modifiable for OEM applications, including alternate body
• Excellent linearity (<4% of full-scale) materials, flow profiles, and more. Call 877-245-6247 to discuss your needs.
• Fast response (<2 ms reaction time)
• Cycle life of typically >1 million cycles
• Repeatability <5% of full travel
• Bi-directional

18 Eclipse Series
1.17” Typical Flow Curves for Air
(29.7)
10
9  10 psig (0.7 bar)
2.60” (66.0) Encoder Shaft 8  20 psig (1.4 bar)
2.91” (73.9) 0.157” dia. (4.0)
 30 psig (2 bar)
7

Air Flow (l/min)


6
0.92”
(23.4) 5
4
3
Standard Manifold (M)
0.178” (4.5) 0.50” 2
(12.7)

0.554” 1
(14.1)
0
1.65” 0 200 400 600 800 1,000 1,200
(41.2)
Port B Steps
#10-32 0.784”
(Bidirectional) (19.9) Port A
#10-32 Typical Flow Curves for Water
(Bidirectional)
0.750” 2x 0.125” 250
(19.1) (3.2) Thru
0.178” (4.5)
 10 psig (0.7 bar)
ZDV Manifold (Z)
2x 0.125” 200  20 psig (1.4 bar)
(3.2) dia. Thru 0.870” (22.1)
(Clearance for  30 psig (2 bar)
Water Flow (ml/min)

#4 or M3)
Port
150
#10-32
(Bidirectional) 0.875”
(22.2)
1.75”
2x 0.125” (44.5) 100
(3.2) dia. Thru 1.082”
(Clearance for (27.5)
#4 or M3) 0.644”
(16.4)
50
0.750” (19.1)
0.125” (3.2) 0.500”
1.00” (25.4) 0.150 (12.7)
(3.8) 0
0 200 400 600 800 1,000 1,200
Dimensions shown are in inches (millimeters listed in parentheses). Steps
Visit clippard.com for more detailed 2D and 3D drawings.

ORDERING INFORMATION

E I V U - ❑ ❑ ❑
Porting
M Manifold
Accessories Encoder Shaft
Z Zero Dead Volume Manifold
EUM-01 Single-Station Manifold, #10-32 -ENS Encoder shaft (standard)
Seals (blank) No encoder shaft
M-EUM-01 Single-Station Manifold, M5x0.8
(blank) ZDVF porting
SCPVD-1 Bipolar Chopper Driver -V FKM
Headless 1/4-28 Flatbottom Fitting, 1/8”
ZDVF-18 Example Part Number:
(3.2 mm) OD (IDEX p/n XP-348) For more info, scan the
EIVU-M-V-ENS QR code or visit
Also Recommended: Miniature optical encoder from US clippard.com/link/eclipse-valve
Digital for 4 mm bore with metric screws (p/n E4T)

TDS EIV-01, Rev. 120424 (2/2) 877-245-6247 | clippard.com 19


SCPV DRIVER

Current / Phase 385 mA


Inductance / Phase 8.08 mH
Insulation Resistance 20M ohms
Motor Voltage 5 VDC
Resistance / Phase 13 ohms
Temperature Rise 135˚F (57˚C)
Wattage 3.85 watts
More Details clippard.com/link/scpvd-driver

*This product is highly modifiable for OEM applications—including alternate body


materials, flow profiles, and more. Call 877-245-6247 to discuss your needs.

The SCPVD is a bi-polar stepper motor driver board which


can be used for stepper motors up to a max 2A/phase. It is
based on the Allegro A4988 motor driver. The driver requires
a motor drive voltage of 7 to 35 volts. An external controller
is required to deliver step and direction signals to the driver
board. The SCPVD is capable of microstepping and defaults
to a 16th step micro-stepping mode. The step mode as well
as several other options such as sleep, enable, and reset can
be toggled on and off.

Max. Step Pulse Frequency


100 For Use with Clippard’s

90

80 SCPV Series
Pressure (psig)

70
Stepper-Controlled
Proportional Valve
60

50
and/or
40

30
Eclipse Proportional
20
Isolation Valve
10

0
545 550 555 560 565 570 575 580 585 590 595

Hertz

20 SCPV Series
Programmable
Logic
Controller Functional Diagram

Step (PLC Output Signal) Red (A+)

Black (A-)
Direction (PLC Output Signal)
SCPV SCPV-1-3
Blue (B+)
Driver

Green (B-)
Power
Supply

Applications
Max. Step Pulse Frequency vs. Operating Pressure
• Analytical instruments
100 • Blood pressure monitoring
90 0.13” (3.3) dia. typ. • Precise pressure control
Mounting Holes
• Patient simulators
80
Pressure (psig)

1.30”
(33.0)
• Gas controllers
70 • Mass flow control
0.64” • Gas chromatography
60 (16.3)
• Respirators / ventilators
50

40
1.15” 0.16” • +7 to +35 VDC supply voltage
(29.2) (4.1)
30
• Max. 2A / phase
20 • 1/16, 1/8, 1/4, 1/2, and full step modes
048”
10 (12.2) • 5V or 3.3V logic inputs (jumper selectable)

0 • LED power supply indicator light


545 550 555 560 565 570 575
• Crossover 580
current 585
protection 590 595
1.45” (36.8) Hertz • Thermal shutdown circuitry

Dimensions shown are in inches (millimeters listed in parentheses).

ORDERING INFORMATION

S C P V D - 1

Example Part Number: For more info, scan the


SCPVD-1 QR code or visit
clippard.com/link/scpvd-driver

TDS SCPVD-01, Rev. 011224 (2/4) 877-245-6247 | clippard.com 21


PRECISION CONTROL SOLUTIONS

ELECTRONIC VALVES PROPORTIONAL VALVES ISOLATION VALVES


Clippard revolutionized the electronic For optimal controllability, proportional Media isolation valves are used for a
valve market in the early 1970s with the valves provide output proportional to wide variety of applications, including
EV series, which quickly became the input. These types of valves are ideal for those that require precise, repeatable
industry standard for life and reliability. applications which require variable flow dispensing for medical and analytical
This unparalleled history in providing control. instrumentation. Choose from a
new and innovative products continues large variety of sizes, configurations,
today, aided by advanced manufacturing materials, and options or contact us to
machines and techniques. discuss special customizations.

clippard.com/link/elec-valves clippard.com/link/prop-valves clippard.com/link/isolation-valves

CONTROL VALVES DIRECTIONAL CONTROL AIR PILOT VALVES


VALVES
From flow controls to needle valves, The force output of an air pilot is
check valves, shuttle valves, exhaust Clippard’s line of mechanically- much more powerful than the power
valves and more, Clippard’s control operated directional control valves produced from electrical solenoids or
valves are available in a wide range includes toggle, stem, and lever valves actuators. This makes air pilot valves
configurations and functions. Sizes as well as hand and foot-actuated pedal ideal for applications where higher air
range from #3-56 and #10-32 through valves, palm button valves, and more. flow and/or lower power are required,
3/8” NPT, for pressures up to 300 psig. Choose from #3-56, #10-32, 1/8” NPT or as well as when simplicity and cost
1/4” NPT ports. savings are important.

clippard.com/link/control-valves clippard.com/link/directional-valves clippard.com/link/air-pilot-valves

22 Clippard Product Line Overview


ELECTRONIC CONTROLS PRESSURE REGULATORS CUSTOM SOLUTIONS
Clippard’s Cordis series is a highly- Regulators are offered in either Clippard excels at designing special
customizable line of electronic controls relieving or non-relieving versions with variations, modifications, and
designed to help close the loop around a large variety of adjustment options completely custom valves, fittings,
pressure and flow. With unparalleled and mounting styles to choose from. and assemblies. If you need a product
accuracy and resolution, this line will For even greater precision control, that fits your application perfectly, we
elevate your application to the next check out Clippard’s Cordis line of will work with you to design or modify
level. Take control like never before electronic pressure regulators. products to suit your exact needs.
with the Cordis.

clippard.com/link/elec-controls clippard.com/link/press-reg clippard.com/link/custom

AIR PREP EQUIPMENT FITTINGS HOSE & TUBING


Pneumatic applications with properly Small in size but large in performance, Choose from a large variety of
conditioned air will operate longer, cost Clippard precision fittings are designed miniature hose and tubing, including
less, and improve system efficiency. to save you time, space, and money copper and nylon tubing, flexible
Clippard’s line includes filters, regulators, when designing versatile, efficient, urethane and vinyl hose and tubing,
lubricators, and combination units from trouble-free circuits. Choose from an and food-, medical-, or laboratory-
#10-32 up to 1”. A modular design and endless variety in several different grade silicone tubing.
interconnecting hardware simplifies styles including push-quick, slip-on,
installation and maintenance. barb, and quick connect.

clippard.com/link/air-prep clippard.com/link/fittings clippard.com/link/tubing

877-245-6247 | clippard.com 23
Clippard products are distributed through our worldwide
network of sales and engineering specialists. All of
our representatives are stocking distributors and keep
a variety of Clippard products on hand to fill your
immediate needs. Each of our distributors are backed by
our own large inventory to ensure quick delivery.

To locate your nearest distributor, call 877-245-6247


or visit clippard.com/distributors

ELECTRONIC VALVES

PROPORTIONAL VALVES

ISOLATION VALVES

ELECTRONIC CONTROLS

CUSTOM SOLUTIONS

PRESSURE REGULATORS
United States Europe China
CONTROL VALVES 1-877-245-6247 +32 10-45-21-34 +86 137-9527-9010

DIRECTIONAL CONTROL VALVES

AIR PILOT VALVES


DISTRIBUTED BY:
AIR PREPARATION EQUIPMENT

FITTINGS, HOSE, & TUBING

Scan QR code or visit


clippard.com/link/request-literature
to request additional literature.

BRO-PROP-01, Rev. 121024

You might also like