0% found this document useful (0 votes)
0 views

Backburner

The document outlines the electrical installation requirements for a project at Pangasinan State University, including compliance with national and local codes. It specifies the types of lighting fixtures, wiring specifications, and mounting heights for various electrical devices. Additionally, it mandates that all installations be supervised by a licensed electrical engineer or registered master electrician.

Uploaded by

daniahjulienne
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
0 views

Backburner

The document outlines the electrical installation requirements for a project at Pangasinan State University, including compliance with national and local codes. It specifies the types of lighting fixtures, wiring specifications, and mounting heights for various electrical devices. Additionally, it mandates that all installations be supervised by a licensed electrical engineer or registered master electrician.

Uploaded by

daniahjulienne
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

LEGENDS :

RECESSED PIN LIGHT GENERAL NOTES :


CEILING FAN
1. ALL ELECTRICAL WORKS, HEREIN SHALL BE DONE IN ACCORDANCE
WITH THE REQUIREMENTS OF THE NATIONAL BUILDING CODE, THE
RECTANGULAR LED LIGHTS
PHILIPPINE ELECTRICAL CODE, THE RULES AND REGULATION OF
THE LOCAL GOVERNMENT, AND THE REQUIREMENT OF THE LOCAL
PENDANT LIGHTS
ELECTRIC UTILITY
2. ALL MATERIALS TO BE USED SHALL BE NEW AND OF GOOD QUALITY.
STRIP LIGHTS
3. LIGHTING BRANCH CIRCUIT SHALL BE 3.5 sq.mm THHN STRANDED
CHANDELIER WIRE IN 20mmØ PVC PIPE.
4. CONVENIENCE OUTLET CIRCUIT SHALL BE 3.5 sq.mm THHN
LED FRAME PANEL LIGHT STRANDED WIRE IN 20mmØ PVC PIPE.
5. AIRCON OUTLET CIRCUIT SHALL BE 8.0 sq.mm THHN STRANDED WIRE
CO
CONVENIENCE OUTLET IN 20mmØ PVC PIPE.
6. MOUNTING HEIGHT OF DEVICE SHALL BE AS FOLLOWS UNLESS
ACU

AIRCON OUTLET NOTED OTHERWISE


RANGE
RANGE OUTLET
PANEL BOARD 1500mm ABOVE FINISHED FLOOR
LAUNDRY
LAUNDRY OUTLET LOCAL SWITCHES 1400mm ABOVE FINISHED FLOOR
CONVENIENCE OUTLET 300mm ABOVE FINISHED FLOOR
REF
REFRIGERATOR OUTLET 170mm ABOVE COUNTERS
AIRCON OUTLET 2000mm ABOVE FINISHED FLOOR
PB EMERGENCY LIGHT 300mm BELOW FINISHED CEILING
PANEL BOARD

CIRCUIT RUN 7. ALL LOCAL SWITCHES TO BE CONNECTED SHALL BE RATED 15 AMP


8. ALL ELECTRICAL INSTALLATIONS SHALL BE UNDER THE
Sa 1 GANG SWITCH SUPERVISION OF A DULY LICENSED ELECTRICAL ENGINEER OR
REGISTERED MASTER ELECTRICIAN.
Sab 2 GANG SWITCH

Sabc 3 GANG SWITCH

SCHOOL/COLLEGE: SUBJECT CODE/DESCRIPTION: DRAWING TITLE: SHEET CONTENTS: SHEET NO.: RATING:
PANGASINAN STATE UNIVERSITY BT124 BUILDING TECHNOLOGY 4 LEGEND AND GENERAL 26