ISCOM2812GF Hardware Installation User Manual 200608
ISCOM2812GF Hardware Installation User Manual 200608
com
Warranty.
A copy of the specific warranty terms applicable to your Raisecom product and replacement parts
can be obtained from Service Office.
All rights are reserved. No part of this document may be photocopied, reproduced, or translated to
another language without the prior written consent of Raisecom Technology Co., Ltd. The
information contained in this document is subject to change without notice.
Copyright Notices.
No part of this publication may be excerpted, reproduced, translated or utilized in any form or by any
means, electronic or mechanical, including photocopying and microfilm, without permission in
Writing from Raisecom Technology Co., Ltd.
Trademark Notices
Microsoft Corporation.
Contact Information
Technical Assistance Center
The Raisecom TAC is available to all customers who need technical assistance with a Raisecom
product, technology, or, solution. You can communicate with us through the following methods:
Address: 2nd Floor, South Building of Rainbow Plaza, No.11 Shangdi Information Road,
Haidian District, Beijing 100085
Tel: +86-10-82883305
Fax: +86-10-82883056
You can access the most current Raisecom product information on the World Wide Web at the
following URL:
http://www.raisecom.com
Feedback
Comments and questions about how the ISCOM2812GF switch works are welcomed. Please review
the FAQ in the related manual, and if your question is not covered, send email by using the following
web page:
http://www.raisecom.com/en/xcontactus/contactus.htm.
If you have comments on the ISCOM2812GF device specification, instead of the web page above,
please send comments to:
Relevant Manuals
《ISCOM2812GF Series Switches Commands Notebook》
Organization
Chapter 1: Overview
This chapter introduces the content of the manual and other relevant reference documents and
explains relevant term definitions.
This chapter is an instruction of the device specifications, device dimension and device operating
environment.
This chapter describes the panel of the device and the definition of the indicators on the device panel.
This chapter introduces the cables and sub cards that may be applied during the installation process.
Chapter 5: Notes
This chapter explains other detailed requirements that must be satisfied during the installation.
www.raisecom.com User Manual
The following instructions serve as a general guide for the safe installation and operation of telecommunications
products. Additional instructions, if applicable, are included inside the manual.
Safety Symbols
This symbol may appear on the equipment or in the text. It indicates potential
safety hazards regarding product operation or maintenance to operator or service
personnel.
Danger of electric shock! Avoid any contact with the marked surface while the
product is energized or connected to outdoor telecommunication lines.
Protective earth: the marked lug or terminal should be connected to the building
protective earth bus.
Some products may be equipped with a laser diode. In such cases, a label with
the laser class and other warnings as applicable will be attached near the optical
transmitter. The laser warning symbol may be also attached.
Please observe the following precautions:
• Before turning on the chassis with optic module, make sure that the fiber optic
cable is intact and is connected to the transmitter.
• Do not attempt to adjust the laser drive current.
• Do not use broken or unterminated fiber-optic cables/connectors or look straight at the
laser beam.
• The use of optical devices with the equipment will increase eye hazard.
• Use of controls, adjustments or performing procedures other than those specified herein, may
result in hazardous radiation exposure.
ATTENTION: The laser beam may be invisible!
Always observe standard safety precautions during installation, operation and maintenance of this
product. Only qualified and authorized service personnel should carry out adjustment, maintenance
or repairs to this product. No installation, adjustment, maintenance or repairs should be performed by
either the operator or the user.
Before operating modules in the electricity conditions, please be noticed that optical modules shall
be connected with optical fiber wires or shield with optical module cover for fear that laser light
harms to operator’s eyes.
be present inside certain products even when the power switch (if installed) is in the OFF position or
a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous,
energy hazards may still exist.
Before working on equipment connected to power lines or telecommunication lines, remove jewelry
or any other metallic object that may come into contact with energized parts.
Unless otherwise specified, all products are intended to be grounded during normal use. Grounding
is provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth
lug is provided on the product, it should be connected to the protective earth at all times, by a wire
with a diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed
racks and cabinets.
Always make the ground connection first and disconnect it last. Do not connect telecommunication
cables to ungrounded equipment. Make sure that all other cables are disconnected before
disconnecting the ground.
Connection of AC Mains
Make sure that the electrical installation complies with local codes.
Always connect the AC plug to a wall socket with a protective ground.
Always connect the power cord first to the equipment and then to the wall socket. If a power switch
is provided in the equipment, set it to the OFF position. If the power cord cannot be readily
disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency
switch is installed in the building installation.
Connection of DC Mains
Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to
the ground. Any single pole can be externally grounded.
Due to the high current capability of DC mains systems, care should be taken when connecting the
DC supply to avoid short-circuits and fire hazards.
DC units should be installed in a restricted access area, i.e. an area where access is authorized only to
qualified service and maintenance personnel.
Make sure that the DC supply is electrically isolated from any AC source and that the installation
complies with the local codes.
Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate
the circuit breaker of the panel board that services the equipment and switch it to the OFF position.
When connecting the DC supply wires, first connect the ground wire to the corresponding terminal,
then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position.
A readily accessible disconnect device that is suitably rated and approved should be incorporated in
the building installation.
2
www.raisecom.com User Manual
Chapter 1 Overview
This manual focuses on the hardware installation and employment of ISCOM2812GF switch. For the
configuration and operations of the switch based on software, please refer to the corresponding
software configuration guide.
10BASE-T A term in IEEE 802.3 for Ethernet over CAT-3 or better twisted pair,
based on Manchester coding and running at 10Mbps.
100BASE-TX A term in IEEE 802.3 for Fast Ethernet over CAT-5 twisted pair, based on
4B/5B coding and running at 100Mbps.
1000BASE-X A term in IEEE 802.3 for Gigabit Ethernet over fiber, based on 8B/10B
coding and running at 1000Mbps.
Auto The auto negotiation procedure is: the port at one site adapts its bit rate
Negotiation and duplex mode to the highest level it and the opposite site device both
support according to the bit rate and duplex mode adopted by the remote
site device, that is, the connected devices on both site adopt the fastest
transmission mode they both support after the auto negotiation process.
RJ-45 The 8 position modular connector applied in twisted pair cable link
MDI Medium Dependent Interface, the name for the connector physically and
electrically connects the media converter and the media segment.
3
www.raisecom.com User Manual
4
www.raisecom.com User Manual
3 5 6 2
4 3
① The logo and model of the switch are RAISECOM and ISCOM2812GF respectively.
③ 12 Ethernet interfaces numbered 1 ~ 12. (9 ~ 12 are combo interfaces including both SFP and
RJ-45 interfaces).
④ 12 groups of indicators for the 12 SFP Ethernet interfaces (including 8 independent SFP and the
4 SFP in the combo interfaces). There are 2 indicators of each SFP interface: LNK and ACT.
5
www.raisecom.com User Manual
⑤ The status indicators for the 4 RJ-45 electrical interfaces in the 4 combo interface: LNK/ACK
and 1000M.
2 2
3 1 1
① Socket for power supply (Can be socket for 220V AC power supply or -48V DC power supply
according to the configuration.)
4.2.3 Grounding
To ensure the safety of the device and the operator, please make sure that the grounding terminal is
well connected to the earth.
The CONSOLE interface of ISCOM2812GF is in the form of RJ-45. The RJ-45 connector and jack
and the corresponding pin number is shown in the figure below.
7
www.raisecom.com User Manual
3 RxD IN
6 TxD OUT
4, 5 GND Ground
1, 2, 7, 8 N.C.
The pin number and pin function definition of 9-pin serial port connector is shown in the figure and
table below.
1 CD 6 DSR
2 RxD IN 7 RTS
4 DTR 9 RI
5 GND
The connecting of ISCOM2812GF CONSOLE interface and PC serial port is shown in the figure
8
www.raisecom.com User Manual
below.
3 TxD TxD 6
2 RxD RxD 3
5 GND GND 4、5
PC Serial Pot CONSOLE
The values of the connecting parameters of the terminal simulation program on the PC are as
follows:
9 Data Bit: 8
9 Stop Bit: 1
The 4 Ethernet electrical interfaces in the 4 combo interfaces of ISCOM2812GF switch have Auto
MDI/MDIX function. The interface can switch between MDI and MDIX automatically. The
connection can be established successfully regardless of the type of interface (MDI or MDIX) the
opposite site of the connection adopts or the type of cable (straight through or crossover) applied.
For RJ-45, the definition of MDI and MDIX signal is shown in the table below. For the pin
numbering of RJ-45 connector and jack, please refer to the “CONSOLE interface signal definitions
of the switch” in section 4.3.1.
1 RD+ TD+
2 RD- TD-
3 TD+ RD+
6 TD- RD-
4, 5, 7, 8 N.C. N.C.
The Ethernet electrical interfaces of ISCOM2812GF switch works at MDIX mode when the
auto-adaptation function is disabled. In this circumstance, the interface can be connected to an
opposite PC with MDI interface by straight through cable.
9
www.raisecom.com User Manual
ISCOM2812GF/DC adopts -48V DC power supply. Please connect the socket on the rear panel of
the switch with -48V DC power supply using the provided power supply cable.
1) Straight through cable (The straight through cable for 100M or 1000M are identical.)
10
www.raisecom.com User Manual
11
www.raisecom.com User Manual
Chapter 5 Notes
The installation, maintenance, plugging in and pulling out of components of ISCOM2812GF switch
can only be conducted by qualified technical support staff. Please place the device in a
temperature-controllable and humidity-controllable room and please be cautious of the conductivity
of the materials around the device. Please note that a room with high humidity exposes the device to
short circuit; while low humidify may lead to fire alarm. In a word, the switch must be placed in
proper surroundings.
¾ The power supply of the device should be well earthed to let out the static electricity.
¾ Please keep some space from other powered devices when installing the switch.
¾ The cable arrangement of the switch should have all cables be placed across the live wire.
Long-distance close parallel of the cables and the live wire must be avoided.
¾ Please operate following the instructions in this manual strictly.
¾ Please avoid operating the switch with wet hands or hands with too much sweat.
¾ Any mechanical and electrical modifications to the switch are strictly forbidden.