Error Codes List page 9
All About this machine Error Code:
page
Code: 7220
Description:
Broken in-machine thermistor wire The sensor input sampling value is greater than the reference value.
Remedy:
In-machine temperature sensor 1. Confirm that the wiring connector is firmly connected, Insert the
connector all the way in. In-machine temperature sensor - Main/engine PWB (YC1) 2. If the wiring is
disconnected, shortcircuited or has a ground fault, replace the wire. Replace the in-machine
temperature sensor PWB.
Main/Engine PWB Replace the main/engine PWB.
Code: 7800
Description:
Broken outer thermistor wire The sensor input sampling value is abnormal. (After detecting an error, it is
controlled at 23C/77 °F and 50%RH)
Remedy:
Temperature and humidity Sensor 1. Confirm that the wiring connector is firmly connected, and if
necessary, connect the connector all the way in. Temperature and humidity sensor - Main/engine PWB
(YC2) 2. If the wiring is disconnected, shortcircuited or has a ground fault, replace the wire. 3. Replace
the Temperature and humidity sensor PWB.
Main/Engine PWB Replace the main/engine PWB.
Code: 7990
Description:
Waste toner full The waste toner sensor detected the waste toner reservoir in the drum unit is full
Remedy:
Drum unit Turn the power switch off and on Replace the drum unit if not repaired.
Waste toner sensor Replace the waste toner sensor.
Main/Engine PWB Replace the main/engine PWB.
Code: F000
Description:
Communication error between Main/Engine PWB - Operation panel PWB
Remedy:
Connection of the wires and connectors between the main/engine PWB - the operation panel PWB. If
the connector is not inserted enough, reinsert it. Or check the wire's continuity and replace the wire if
there is no continuity.
Operation panel PWB Replace the operation panel PWB. (TSI: see page 4-138, LCD: see page 4- 141)
Main/Engine PWB Replace the main/engine PWB.
Code: F010
Description:
Main/Engine PWB Checksum error
Remedy:
Main/Engine PWB Unplug the power cord from the wall outlet, and wait five seconds. Then plug in the
power cord and then turn on the power switch. If not corrected, replace the main/ engine PWB.
Code: F020
Description:
Main/engine PWB RAM checksum error
Remedy:
Main/engine PWB memory (RAM) Turn the power switch off and on If not corrected, replace the main/
engine PWB.
Expansion memory (DIMM) Replace the expansion memory (DIMM)
Error Codes List page 10
All About this machine Error Code:
page
Code: F040
Description:
Main/engine PWB engine communication error
Remedy:
Main/Engine PWB Turn the power switch off and on If not repaired, replace the EEPROM on the
main/engine PWB or main/engine PWB.
Code: F041
Description:
Main/engine PWB - Scanner PWB communication error
Remedy:
Main/Engine PWB Turn the power switch off and on If not corrected, replace the main/ engine PWB.
Code: F050
Description:
Main/engine PWB engine checksum error
Remedy:
Main/Engine PWB Download the engine firmware again (TSI: see page 4-138,LCD: see page 4- 141)
Main/Engine PWB Turn the power switch off and on If not repaired, replace the EEPROM on the
main/engine PWB or main/engine PWB.
Code: F051
Description:
No scan engine main program
Remedy:
Main/Engine PWB Turn the power switch off and on If not corrected, replace the main/ engine PWB.
Code: F12X
Description:
Abnormality detecting in a Scan control section
Remedy:
(1) Check the harness between Scan/DP<=>Main/Engine PWBs, and the connection state of a connector,
and perform an operation check. (2) U021 Controller backup initialization is carried out and an operation
check is performed. (3) Exchange a Scan/DP board and perform an operation check. (4) Exchange a
Main/Engine PWB and perform an operation check. (5) Get USBLOG and contact service headquarters.
Code: F14X
Description:
Abnormality detecting in a FAX control part
Remedy:
(1) Check the harness between FAX<=>Main/Engine PWBs, and the connection state of a connector, and
perform an operation check. (2) U021 Controller backup initialization is carried out and an operation
check is performed. (3) Perform a deed operation check for DIMM Clear by U671. * Notes(Since it
disappears when received data remain, cautions are required.) (4) Exchange a FAX board and perform
an operation check. (5) Exchange a Main/Engine PWB and perform an operation check. (6) Get USBLOG
and contact service headquarters.
Error Codes List page 11
All About this machine Error Code:
page
Code: F15X
Description:
Abnormality detecting in an authentication device control section
Remedy:
(1) Check the harness between authentication device <=>Main/ Engine PWBs, and the connection
situation of a connector, and perform an operation check. (2) Carry out U021 Main backup initialization
and perform an operation check. (3) Exchange a Main/Engine PWB and perform an operation check. (4)
Get USBLOG and contact service headquarters.
Code: F18X
Description:
Abnormality detecting in a Video control section
Remedy:
(1) Check the harness between Engine<=>Main/Engine PWBs, and the connection state of a connector,
and perform an operation check. (2) U021 Controller backup initialization is carried out and an operation
check is performed. (3) Exchange a Main/Engine PWB and perform an operation check. (4) Get USBLOG
and contact service headquarters.
Code: F1DX
Description:
Abnormality detecting of the image memory Management Department
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
Code: F21X, F22X, F23X
Description:
Abnormality detecting in an image-processing part
Remedy:
(1) Check contact of a DDR memory and perform an operation check. (2) Carry out U021 Main backup
initialization and perform an operation check. (3) Exchange a Main/Engine PWB and perform an
operation check. (4) Get USBLOG and contact service headquarters.
Code: F24X
Description:
Abnormality detecting in the system Management Department
Remedy:
(1) Check contact of a DDR memory and perform an operation check. (2) Carry out U021 Main backup
initialization and perform an operation check. (3) Exchange a Main/Engine PWB and perform an
operation check. (4) Get USBLOG and contact service headquarters.
Code: F25X
Description:
Abnormality detecting in a network management department
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and packet capture and contact
service headquarters.
Error Codes List page 12
All About this machine Error Code:
page
Code: F26X ... F2AX
Description:
Abnormality detecting in the system Management Department
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
Code: F2BX ... F32X
Description:
Abnormality detecting in a network control part
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
(Depending on an analysis result, it is packet capture acquisition)
Code: F33X
Description:
Abnormality detecting in the Scan Management Department
Remedy:
(1) Check the harness between Scan/DP<=>Main/Engine PWBs, and the connection state of a connector,
and perform an operation check. (2) U021 Controller backup initialization is carried out and an operation
check is performed. (3) Exchange a Scan/DP board and perform an operation check. (4) Exchange a
Main/Engine PWB and perform an operation check. (5) Get USBLOG and contact service headquarters.
Code: F34X
Description:
Abnormality detecting in the Panel Management Department
Remedy:
(1) Check the harness between Panel<=>Main/Engine PWBs, and the connection state of a connector,
and perform an operation check. * Notes (2) U021 Controller backup initialization is carried out and an
operation check is performed. (3) Exchange a Panel board and perform an operation check. (4) Exchange
a Main/Engine PWB and perform an operation check. (5) Get USBLOG and contact service headquarters.
Code: F35X
Description:
Abnormality detecting in the printing controlling Management Department
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
Code: F37X
Description:
Abnormality detecting in the FAX Management Department
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
Error Codes List page 13
All About this machine Error Code:
page
Code: F38X
Description:
Abnormality detecting in the authentication authorized Management Department
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
Code: F3AX ... F45X
Description:
Abnormality detecting in the Entity Management Department
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
Code: F46X
Description:
Abnormality detecting of a printer rendering part
Remedy:
(1) Exchange a Main/Engine PWB and perform an operation check. (2) the acquisition wish of USBLOG --
carry out (Depending on the (2) case, it is print capture data acquisition)
Code: F47X, F48X, F49X
Description:
Abnormality detecting of an image editing processing part
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
Code: F4DX, F4EX
Description:
Abnormality detecting in the Entity Management Department
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
Code: F4FX
Description:
Abnormality detecting in the JOB Management Department
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
Kyocera ECOSYS M2040dn
Error Codes List page 14
All About this machine Error Code:
page
Code: F50X
Description:
Abnormality detecting in the FAX Management Department
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
Code: F51X ... F57X
Description:
Abnormality detecting in a JOB execution part
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
Code: F58X ... F5EX
Description:
Abnormality detecting in the various-services Management Department
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
Code: F5FX
Description:
Abnormality detecting in a service execution part
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
Code: F62X
Description:
Abnormality detecting in a service execution part
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
Code: F63X
Description:
Abnormality detecting in a device control section
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
PrintCopy.info service
Search by model Kyocera
Catalog Sign In Contacts Forum Eng
USD 0.00
Discount 0.0%
Parts List 0
Error Codes
Kyocera
ECOSYS M2040dn
All codes
Kyocera ECOSYS M2040dn
Error Codes List page 15
All About this machine Error Code:
page
Code: F69X ... F6CX
Description:
Abnormality detecting in a HyPAS-E part
Remedy:
(1) Carry out U021 Main backup initialization and perform an operation check. (2) Exchange a
Main/Engine PWB and perform an operation check. (3) Get USBLOG and contact service headquarters.
Error Code
Parts Catalog
Service Mode, Troubleshooting
Downloads Files
Used abbreviations
Compatibility
Discounts
Payments
Privacy, Terms, Refunds
Total in database
Brands: 24
Models: 8626
Kyocera: 438
PrintCopy .info service 2001 - 2025