YouTube Playlists - How to videos (Worldwide)
How to: Altivar Soft Starters How to: Altivar Machine ATV320
25 videos 25 videos
https://youtube.com/playl https://youtube.com/pla
ist?list=PLa7UGrWOTyjmo ylist?list=PLa7UGrWOTyj
XYQk91jbn01VFDXnPakF kmuiHyakGthhIvucpha0lY
Internal
Altivar Process – ATV 660
690V
Confidential Property of Schneider Electric | Page 5
Internal
Technical Specifications
Control Terminals ATV6xx
● 6 Digital Inputs
● 3 Analogue Inputs
● 3 Relays
● 2 Analogue Outputs
Schneider Electric - Drives Skills Development - Altivar Process – M2 – Main features - 20160518 6
General
Technical Specifications
The Control Inputs / Outputs ATV6xx / ATV9xx
● Internal sources
● Protected against short circuit
● + 24VDC (21VDC to 27VDC) – 200mA
To supply STO
● + 24VDC (21VDC to 27VDC) – 200mA
To supply the logic inputs
● + 10VDC (0 / +5%) – 10mA
● External power supply (P24)
● To supply also eventually the logic inputs
and STO
● Protected against over voltage
● + 24VDC (19VDC to 30VDC) – 1,25A max.
● In compliance with IEC 65A-68 standard
Schneider Electric - Drives Skills Development - Altivar Process – M2 – Main features - 20160518 7
General
Technical Specifications
The Digital Inputs ATV6xx
Schneider Electric - Drives Skills Development - Altivar Process – M2 – Main features - 20160518 8
General
IP Rating and air flow for IP21
Common air flow for Power & Control
IP23 IP54
Filter
pads
10%
(filtered)
100%
90%
Internal
Wiring
Internal
Wiring
Internal
Wiring
Internal
Wiring
Internal
Wiring
Internal
Drive Status
Setting Code / Value Description
[Auto-tuning] tUn Autotuning
[In DC inject.] dCb Injection braking
[Ready] rdY Drive ready
[Freewheel] nSt Freewheel stop control
[Running] rUn Motor in steady state or run command present and zero reference
[Accelerating] ACC Acceleration
[Decelerating] dEC Deceleration
[Current limitation] CLI Current limit
[Fast stop] FSt Fast stop
[Mot. fluxing] FLU Fluxing function is activated
[No Mains Voltage] nLP Control is powered on but the DC bus is not loaded
[STO Active] PrA Power removal function has been activated
[control.stop] CtL Controlled stop
[Dec. adapt.] Obr Adapted deceleration
[Output cut] SOC Stand by output cut
[Undervoltage Warning] USA Undervoltage warning
[TC Mode Active] tC TC indus mode activated
[In autotest] St Self test in progress
[Autotest error] FA Self test detected error
[Autotest OK] YES Self test OK
[EEprom test] EP Self test EEPROM detected error
[“Operating State "Fault“] FLt Product has detected error
[DCP Flashing Mode] dCP DCP flashing mode
[STO Active] StO Safety function STO level
[Energy Saving] IdLE Idle stop and go mode
Schneider Electric - Drives Skills Development - Altivar Process – WS1 – Demo Case Setup Basic - 20150113
Summary
17
Simply Start
● https://www.se.com/us/en/faqs/FA306088/
● https://youtu.be/1A_9ZUAXjpQ?si=PLDNryvcVaO-8LT4
Schneider Electric - Drives Skills Development - Altivar Process – WS1 – Demo Case Setup Basic - 20150113
Summary
18
Motor Nameplate
Schneider Electric - Drives Skills Development - Altivar Process – WS1 – Demo Case Setup Basic - 20150113
Summary
19
THANK YOU
Internal
Internal