0% found this document useful (0 votes)
28 views10 pages

Wet Chemical System

Kidde Fire Systems offers a range of fire suppression systems, including the WHDR Wet Chemical System for kitchens and ECS Clean Agent Systems for various commercial applications. These systems provide rapid response, damage-free operation, and environmentally safe solutions tailored to specific hazards. Kidde's products are designed for flexibility, efficiency, and compliance with safety standards, making them a trusted choice for fire protection worldwide.

Uploaded by

amin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views10 pages

Wet Chemical System

Kidde Fire Systems offers a range of fire suppression systems, including the WHDR Wet Chemical System for kitchens and ECS Clean Agent Systems for various commercial applications. These systems provide rapid response, damage-free operation, and environmentally safe solutions tailored to specific hazards. Kidde's products are designed for flexibility, efficiency, and compliance with safety standards, making them a trusted choice for fire protection worldwide.

Uploaded by

amin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

www.kiddefiresystems.

com

Kidde® WHDR™ Wet Chemical System


24 Hour Protection for Cooking Facilities

The heart and soul of every dining establishment is the Why Choose a Kidde WHDR System?
kitchen. Equipped with ranges, broilers, fryers and a
Economical. Cost-effective, pre-engineered system
myriad of other high-temperature cooking appliances, no
simplifies design and installation.
other environment demands proper fire protection more
than today’s modern cooking facilities. Easy-to-maintain. Semi-annual system inspections and
routine maintenance per NFPA regulations are performed
The Kidde WHDR system is specifically designed for the
quickly and efficiently by your local Kidde distributor.
challenging demands posed by cooking applications. By
offering one of the most flexible system configurations Proven Protection. Providing the best in kitchen fire
in the industry, Kidde Fire Systems provides efficient, protection for over 40 years, Kidde fire suppression systems
economical protection for all types of cooking facilities are the choice of countless restaurants and cooking
and design layouts. Our customized approach allows you facilities worldwide.
to specify the type of detection, control and cylinder
24/7 Support. Designed, installed and serviced by our
sizes to fit your application.
factory trained, global network of Kidde Fire Systems
Investing in a Kidde WHDR system helps to enable more distributors.
than just code compliance for your appliance (UL300,
Customized Solution. System design and installation
NFPA 96 & 17A); it provides automatic, round the clock
provided by your local distributor, delivering a superior
protection from the devastating consequences of fire.
code-compliant solution which is tailored to your fire
protection needs.
When you choose Kidde, Robust Design. Meets strict
you’ve chosen the world’s UL 300 fire test criteria,
suppressing fire without the
most respected name in need for secondary agent or
special hazards fire protection. system connections.
Reliable. Every WHDR system is
backed by the Kidde warranty.
How Kidde WHDR Wet Chemical Systems Work Customers Protected
1. Fire is detected by the Kidde mechanical link, or electric Detect-A-Fire® • Fast Food Chains
(DAF), or the system is manually activated by a remote pull station.
• Hotels & Lodging
2. The XV™ Control System simultaneously actuates up to 20 pressurized
• Fine Dining
agent storage containers, shuts down fuel and power sources to the
appliances and activates the building fire alarm. • Healthcare Facilities

3. Kidde APC wet chemical agent, designed specifically for the • Sports Stadiums and Complexes
challenges posed by oil and grease in a kitchen environment, is • Casual & Family Dining
propelled through the system piping by the stored pressure container.
• Marine Galleys
4. The Kidde APC agent discharges from strategically positioned
• Educational Facilities
nozzles protecting the hood, duct and appliances. APC agent quickly
suppresses the flames and forms a protective layer that not only • Supermarkets/Groceries
extinguishes the fire, but also prevents re-ignition. • Institutional Facilities
• Diners
Kidde WHDR System Components
• Corporate Cafeterias
• XV Control System
• Nursing Homes
• WHDR Agent Storage Container
• Thermo Bulb, Fusible Link or DAF Detection • Shopping Mall Food Courts
• Manual Remote Release
• Mechanical or
Applications Protected
Electric Gas Valve • Hoods, Plenums & Filters
• Customized Discharge • Ductwork
Nozzles
• Fryers
• APC Wet
Chemical Agent • Ranges
• Char-broilers
• Woks
• Griddles

We are Kidde Fire Systems. • Salamanders

Kidde Fire Systems’ products save people and property from the dangers • Tilt Skillets
of fire. Our broad product offering and design expertise have been • and more…
protecting assets worldwide since 1917. We’re the smart choice when
early fire detection and suppression needs are especially demanding. Approvals & Listings
To advance our leadership in the industry, our family of special hazard • UL Listed
fire protection brands has united. Kidde Fire Systems now incorporates
• ULC Listed
Chemetron Fire Systems and Fenwal Protection Systems. As Kidde
Fire Systems, we will enhance our customer focus and partnerships, • NYC Fire Department (COA)
provide highly efficient service and training, preserve a deep combined • ABS Type Approved
expertise in an array of vertical markets, and accelerate our product and
technology developments, to the advantage of everyone who benefits • DNV Type Approved
from a world made safer from fire.
One united company. Advancing fire protection.

400 Main Street


Ashland, MA 01721 USA
Prem Kumar 508.881.2000
Business Development www.kiddefiresystems.com
Manager (SEA) Kidde & Detect-A-Fire are registered trademark of Kidde-Fenwal, Inc.
Cell: +65-91885358 Kidde XV & Kidde WHDR are trademarks of Kidde-Fenwal, Inc.
[email protected] SSK-202 Nov 2014 ©Kidde-Fenwal, Inc., All Rights Reserved.
www.kiddefiresystems.com

KIDDE® ECS™ 360 PSI


CLEAN AGENT SUPPRESSION SYSTEM
Proven. Effective. Reliable.

Fire Protection that’s Engineered Clean and Safe for Vital Facilities
Equipment and processes are vital to the success of all commercial endeavors. Consider the ramifications of a fire in these
critical areas. Smoke or soot contamination, water damage, destroyed equipment and idle process lines could force your
business offline and out of competition. Kidde’s ECS 360 psi Suppression System detects and extinguishes fires in seconds,
safeguarding your people, property and bottom line, while maintaining business continuity.

Kidde ECS 360 psi System Benefits:


• Active on Fire, Safe for People – Kidde ECS 360 psi
Suppression System combines the benefits of clean agent
systems and active fire protection with people-safe,
environmentally-friendly performance
• The Right Clean Agent – A range of Clean Agents discharge
as gases, leaving no residue to damage sensitive equipment
or require costly clean-up
• The Right Fire Suppression System – Designed to fully
discharge the clean fire suppression agent into a protected
area within 10 seconds, ensuring the system extinguishes a
fire quickly
• Fully Integrated System – Kidde offers a complete fire
protection system that is designed, manufactured, installed
and serviced by one company

When you choose Kidde, you’ve chosen one


of the world’s most respected names
in special hazards fire protection.
Why Choose a Kidde ECS 360 psi Clean Agent System? Typical Applications
Rapid-Response. In seconds, not minutes, the ECS 360 psi System Protected by an ECS 360 psi
discharges the suppression agent into the hazard area providing the Clean Agent System:
fastest fire protection available. This results in less damage, fewer repair
• Bank Vaults
costs and reduced downtime.
• Battery Backup Rooms
Damage-Free. Removed from the hazard area by ventilation, ECS 360 psi
Clean Agents allow a virtually immediate return to “business as usual” • Clean Manufacturing Facilities
without the interruption of a lengthy clean-up or the expense of • Data Processing Centers
damage to assets from residue.
• Document Storage
People-Safe. ECS 360 psi Clean Agents are non-toxic, when used in
• Hazards up to 30,000 cubic
compliance with NFPA Standard 2001, and do not impair breathing or
feet (850 cubic meters)
obscure vision in an emergency situation, providing an added measure
of safety for personnel. • Process Control Rooms

Environmentally-Conscientious. With a zero Ozone Depletion • Simulators


Potential, a low atmospheric lifetime, and its rapid suppression
performance, ECS 360 psi Clean Agents offer low environmental impact Integrated ECS 360 psi Clean
and reduce the potentially devastating atmospheric pollutants Agent System Components:
of an uncontrolled fire.
• Control Unit
Laboratory-Tested. ECS 360 psi Clean Agents have been tested and
found to be effective on the widest possible range of Class A surface • Smoke Detection
fire (wood, paper and cloth), Class B (flammable liquids) and Class C • Heat Detection
(electrical) fuels.
• Suppression Cylinders
Globally-Accepted. Used in more than 70 countries around the world,
• Notification Devices
ECS 360 psi Clean Agents meet the standards of Underwriters Laboratories,
FM Approvals, the National Fire Protection Association (2001 Standard), • Manual Pull Stations
the U.S. EPA SNAP program and most global approval authorities.
Kidde Fire Systems
Approvals and Listings: Clean Agents:
• UL Listed • HFC-227ea
• FM Approved • 3M™ Novec™ 1230
• USCG Approved Fire Protection Fluid

400 Main Street


Ashland, MA 01721 USA
508.881.2000
www.kiddefiresystems.com
Prem Kumar 3M & Novec are trademarks of 3M Company.
Business Development Kidde is a registered trademark of
Manager (SEA) Kidde-Fenwal, Inc., or its parents, subsidiaries or affiliates.
Cell: +65 91885358
[email protected] SSK-100 February 2018 ©Kidde-Fenwal, Inc., All Rights Reserved.
www.kiddefiresystems.com

KIDDE® ADS™ WITH


3M™ NOVEC™ 1230 FIRE PROTECTION FLUID
CLEAN AGENT FIRE SUPPRESSION SYSTEM
Ideal for Long Distances and Complex Piping Networks

Kidde Fire Systems’ ADS Suppression System with 3M™ Novec™ 1230 Fire Protection Fluid improves the performance
of a standard 360 psi system by using a Nitrogen driver to “push” the agent through the piping network. This
innovation provides better coverage, greater nozzle heights, smaller
diameter pipe and longer pipe runs than a standard clean agent
suppression system.

Kidde ADS System with


Novec™ 1230 Fluid Benefits:
• Flexibility to protect multiple hazards from a single
cylinder bank location by adding 3-way directional valves
• If space is not restricted, placement in or near hazard
area allows for smallest possible pipe diameter to be used,
resulting in installation cost savings
• Increased flow rates allow for better coverage of larger
hazard areas

Kidde ADS System with


Novec™ 1230 Fluid Features:
• Cylinders can be located up to 200 feet from hazard area
• Nozzle can be placed at a height of up to 18’ 6”
• Nozzle coverage area of up to 42’ 6” x 42’ 6”
Why Choose a Kidde ADS with Novec 1230 Fluid System? Typical Applications Protected
Rapid-Response. In seconds, the Kidde ADS with Novec 1230 Fluid System by an ADS with Novec 1230
discharges the suppression agent into the hazard area resulting in less Fluid Clean Agent System:
damage, fewer repair costs and reduced downtime.
• Health Care Facilities
Damage-Free. Removed from the hazard area by ventilation, the clean
• Internet Hosting Facilities
agent allows virtually immediate return to “business as usual” without
the interruption of a lengthy clean-up or the expense of damage to • Larger Manufacturing Complexes
assets from suppressant residue. • Multi-level Sites
People-Safe. Clean agents are non-toxic, when used in compliance • Recording Studios
with NFPA Standard 2001 and do not impair breathing or obscure vision
• Telecommunications Facilities
in an emergency situation, providing an added measure of safety for
personnel.
Integrated ADS with
Environmentally-Responsible. With zero Ozone Depletion Potential,
Novec 1230 Fluid Clean
low atmospheric lifetime, and speedy suppression performance, clean
agents offer low environmental impact and reduce the potentially Agent System Components:
devastating atmospheric pollutants of an uncontrolled fire. • Control Unit
Laboratory-Tested. Clean Agents have been tested and found to be • Smoke Detection
effective on the widest possible range of Class A surface fire (wood,
• Heat Detection
paper and cloth), Class B (flammable liquids) and Class C (electrical) fuels.
• Suppression Cylinders
Globally-Accepted. Used in more than 70 countries around the world,
clean agents meet the standards of Underwriters Laboratories, • Notification Devices
FM Approvals, the National Fire Protection Association (2001 Standard), • Manual Pull Stations
the U.S. EPA SNAP program and most global approval authorities.

Approvals & Listings:


• UL Listed
• FM Approved
• USCG Approved

400 Main Street


Ashland, MA 01721 USA
508.881.2000
www.kiddefiresystems.com
Prem Kumar Novec is a trademark of 3M Company.
Business Development Kidde is a registered trademark of
Manager (SEA) Kidde-Fenwal, Inc., or its parents, subsidiaries or affiliates.
Cell: +65 91885358
[email protected] SSK-108 March 2018 ©Kidde-Fenwal, Inc., All Rights Reserved.
www.kiddefiresystems.com

KIDDE® ECS-500™ WITH FK-5-1-12


CLEAN AGENT SUPPRESSION SYSTEM
Optimize cylinder storage location for flexible and cost-effective installation
The ECS-500 Clean Agent Suppression System is the newest entry in our engineered clean agent suppression product line. The
higher pressure (500 psi/34.5 bar) of the ECS-500 provides superior system performance as compared to 360 psi/25 bar systems.
Now you have the flexibility of a mid-tier solution between our standard ECS™ and Advanced Delivery System (ADS™)
to meet application size, design requirements and the client’s budget.

Kidde ECS-500 System Benefits:


The ECS-500 system provides all the benefits of the standard ECS system
with added advantages that provide improved system design flexibility
and reduced installation and material costs:
• New 1,100 lb. cylinder reduces cylinder quantities and
installation time required, while providing enough agent
to cover up to a 27,000 ft.3 area with a single cylinder
• Increased system pressure allows for longer pipe runs and
use of smaller pipe diameters
• Provides flexibility to remotely locate cylinder storage area
more than twice the distance from the hazard area when
compared to 360 psi/25 bar systems

Kidde ECS-500 System Features:


• A wide range of filling capacities from 6 lbs. to 1,100 lbs.
• Fire protection of up to 27,000 ft.3 with a single cylinder
• Provides economical protection of multiple enclosures when
used with directional valves

When you choose Kidde, you’ve chosen one


of the world’s most respected names in
special hazards fire protection.
Why Choose a Kidde ECS-500 Clean Agent System? Typical Applications
Rapid-Response. In seconds, the ECS System discharges the suppression Protected by an ECS-500
agent into the hazard area resulting in less damage, fewer repair costs
and reduced downtime than a standard code-compliant sprinkler system.
• Data Processing Centers
Damage-Free. Removed from the hazard area by ventilation, ECS-500
• Process Control Rooms
Clean Agent (FK-5-1-12) allows a virtually immediate return to “business
as usual” without the interruption of a costly clean-up and the expense • Clean Manufacturing Facilities
of damage to assets from residue. • Bank Vaults
People-Safe. ECS-500 Clean Agent (FK-5-1-12) is non-toxic, when used in • Simulators
compliance with NFPA Standard 2001. ECS Clean Agent does not impair
• Battery Backup Rooms
breathing or obscure vision in an emergency situation, providing an
added measure of safety for personnel. • Document Storage

Environmentally-Conscientious. With a zero Ozone Depletion Potential,


a low atmospheric lifetime, and its rapid suppression performance,
ECS-500 Clean Agent (FK-5-1-12) not only offers low environmental
Agent System Components:
impact, but reduces the potentially devastating atmospheric pollutants of
an uncontrolled fire. • Control Unit
Laboratory-Tested. ECS-500 Clean Agent (FK-5-1-12) has been tested • Smoke Detection
and found to be effective on the widest possible range of Class A
• Heat Detection
surface (wood, paper and cloth), Class B (flammable liquids) and Class C
(electrical) fires. • Suppression Cylinders

Globally-Accepted. Used in more than 70 countries around the world, • Notification Devices
ECS-500 Clean Agent (FK-5-1-12) meet the standards of Underwriters • Manual Pull Stations
Laboratories, FM Approvals, the National Fire Protection Association
(2001 Standard), the U.S. EPA SNAP program and most global approval
authorities.

Approvals and Listings:


• cULus Listed
• FM Approved
• Other marine- and land-based approvals in process

400 Main Street


Ashland, MA 01721 USA
Prem Kumar 508.881.2000
Business Development www.kiddefiresystems.com
Manager (SEA)
Cell: +65 91885358
[email protected] SSK-114 February 2018 ©Kidde-Fenwal, Inc. All Rights Reserved.
www.kiddefiresystems.com

KIDDE® ARIES®-MLX
INTELLIGENT MULTI-LOOP
SUPPRESSION CONTROL UNIT
Flexible, Scalable and Easy to Install

The ARIES-MLX is an intelligent, addressable, multi-loop Fire Alarm Suppression Control Unit that supports Kidde Fire
Systems’ wide array of suppression products and is backward compatible with legacy Kidde®, Fenwal® and Chemetron®
agent release devices. Its versatile, expandable and networkable control platform provides unique features and benefits
for demanding applications that require protection of multiple hazards.

ARIES-MLX Control Unit Benefits: ARIES-MLX Control Unit Features:


• Suppression-focused features and safeguards • Exclusive triple redundancy (Triple-R) safeguards substantially reduce
risk of inadvertent activation caused by microprocessor failure
• Large input, output and release capacity
• 2 SLC loops standard (510 addresses)
• Modular architecture for easy field
expansion and addition of functionality • Expandable: add up to 6 SLC loops, 96 relays or 72 release/NAC
circuits per control unit
• Easy to install, commission and maintain
• 64 network node capacity; 130,560 addresses across a fully
• Enables remote access to system status
loaded network
and events
• Remote release modules supported on SLC, up to 82 for stand-
• Seamless integration with building
alone control unit, thousands for large networks (limitations apply)
management systems
• Remote display and 48 point LED annunciator modules
• Enclosures mountable between standard
16 inch studs • 2-Tier and 3-Tier NEMA 1 enclosures
• Backward compatible • Pluggable terminal blocks
• 4 x 40 LCD display with 4 programmable soft-switches
• Internet connectivity with event viewing and email notification
• Modbus (RTU & TCP/IP) and BACnet (MS/TP & IP) compatibility
• Retrofit kits for upgrading legacy control units
• Listed for use with Kidde, Fenwal and Chemetron agent release
devices including control heads and initiators
• Backward compatible with SmartOne® sensors and modules
Why Choose a Kidde ARIES-MLX Control Unit? Typical Applications Protected
Suppression-focused features and safeguards. The Control Unit and by ARIES-MLX Control Units:
associated peripherals have the agency approvals, features and • Airport Signal Traffic Controls
configuration flexibility required to support the protection of multiple
hazards. The system incorporates triple redundancy (Triple-R) safeguards • Battery Backup Rooms
to substantially reduce inadvertent activation of the suppression system • Data Centers
caused by microprocessor failure.
• Gas Turbines
Complete fire suppression solution and single point of contact.
• Historical and Cultural Buildings
The ARIES-MLX Control Unit is part of a complete solution that includes
the fire suppression system, SmartOne addressable sensors and modules • Industrial Processes
and notification appliances. • Manufacturing Operations
Cost effective and expandable. The Control Unit’s modular architecture • Medical Facilities
allows the base 2 SLC loop system to be expanded up to 8 SLC loops.
• Museums, Libraries and Galleries
It also allows for additional relays, NACs, release circuits and other
functionality to be easily added to protect additional hazards, high- • Records Storage
value assets and personnel when areas are expanded or reconfigured. • Power Generation Plants
Easy to install, commission and maintain. Installation is simple with • University Campus Environments
enclosures that fit between standard 16 inch wall studs, pluggable
• Areas Containing High-Value Assets
terminals that can be removed, wired and connected back into the unit
and a hinged Main Control Board (MCB) that allows easy access to the
power supply and components. Configuration and maintenance is easy Control for Wide Array of Fire
with a user interface that has 4 programmable buttons, easy to use Suppression Systems:
configuration software and programming language, the capability to
send email alerts and a 10,000 event log. • Kidde® ECS™ Clean Agent
• Kidde® ADS™ Clean Agent
Investment Protection. The ARIES-MLX is backward compatible with
Kidde, Fenwal and Chemetron agent release devices including control • Kidde® Inert Gases
heads and initiators and SmartOne sensors and modules. It also supports • Kidde® HP CO2
conversion from previous generation PEGAsys™ and FenwalNET™ 2000
Control Units without replacing the control unit back box, minimizing • Kidde® LP CO2
the impact of replacing existing peripherals, wiring and enclosures. • Kidde® WHDR™ Wet Chemical
• Kidde® IND™ Dry Chemical
Approvals and Listings:
• Fenwal® Initiators
• UL Listed
• Chemetron® Solenoids
• cUL Listed
• Marioff® HI-FOG® Water Mist
• FM Approved

Suppression Systems by Others:


• Sprinkler Supervisory
• Deluge/Pre-action
• Foam and Foam/Water

400 Main Street


Ashland, MA 01721 USA
508.881.2000
Prem Kumar www.kiddefiresystems.com
Business Development
Manager (SEA) Kidde, Fenwal, Chemetron, ARIES and SmartOne are registered
trademarks of Kidde-Fenwal, Inc., or its parents, subsidiaries or affiliates.
Cell: +65 91885358
[email protected] SSK-103 March 2018 ©Kidde-Fenwal, Inc., All Rights Reserved.

You might also like