The document outlines the site development plan for a proposed two-storey residential unit, including detailed architectural and structural drawings. It includes measurements, elevations, and specifications for various areas such as bedrooms, living spaces, and utilities. Additionally, it emphasizes the need for on-site verification of measurements and compliance with design standards.

Uploaded by

tabsamsee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
9 views

combinepdf (14)

The document outlines the site development plan for a proposed two-storey residential unit, including detailed architectural and structural drawings. It includes measurements, elevations, and specifications for various areas such as bedrooms, living spaces, and utilities. Additionally, it emphasizes the need for on-site verification of measurements and compliance with design standards.

Uploaded by

tabsamsee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

CITY / DISTRICT / MUNICIPALITY

O
3.42m
3.90m
4.38m

A
2.00m

2.00m

LAND USE & ZONING

11.08m 8.66m

4.20m

1.12m 3.73m
1.09m 3.78m
1.46m

LINE & GRADE


R O A D

A SITE DEVELOPMENT PLAN


A-01 A-01 SCALE NTS

ARCHITECTURAL

STRUCTURAL
AMORE APARTELLE

Pina
gba
rilan TARCAN BRIDGE
RNV APPLIANCE
Dr. Luis SERVICE
R eyes St.

ELECTRICAL

SITE

reek
A PERSPECTIVE

an C
A-01 A-01 SCALE NTS

Tarc
MECHANICAL

AVICINITYMAP
A-01 A-01 SCALE NTS

SANITARY
REG. NO.: PROJECT TITLE : OWNER : DESIGN BY SHEET CONTENTS
REVISIONS SHEET NO:
ALL MEASUREMENTS ARE TO BE VERIFIED ON SITE BY
TIN NO.: DRAWN BY CONTRACTOR. ALL DISCREPANCIES
ARE TO BE IMMEDIATELY
REPORTED TO ARCHITECTS & NO: DESCRIPTION DATE:
PROJECT MANAGERS.
7

CIVIL ENGINEER
P.T.R. PROPOSED TWO STOREY
RESIDENTIAL UNIT
CAD BY

AS SHOWN
CONTRACTOR ARE TO BE PREPARED & SUBMIT SHOP
DRAWING TO ARCHITECTS PRIOR TO COMMENCEMENT
OF WORKS.
6

5
A
1 3
ISSUED ON: CHECKED BY 4
THIS DRAWING, ACTING AS INSTRUMENT
OF SERVICE, IS THE PROPERTY OF 3
RECIO+CASAS,INC.. & CANNOT BE
PRODUCED WITHOUT THEIR WRITTEN CONSENT.
DATE DRAWN 2
ISSUED AT: SCALE AS SHOWN
ADDRESS : ADDRESS : DATE PRINTED - REPUBLIC ACT No. 545 1
1 2 3 4 1 2 3 4

3.62m 3.50m 4.60m


11.72m 1 2 3 4
3.62m 3.50m 4.60m
2.12m 1.50m
11.72m

E 3.62m 3.50m 4.60m

1.98m L a n a i 1.98m

D D
Bedroom 1 Bedroom 2 APEX

Walk in
C l o se t 1.30m
4.10m Kitchen 4.10m 4.10m
T & B 4.10m
4.00m Laundry Tongue and Groove
A r e a TOP OF ROOF BEAM
Plastered Finish

Mirror
Dining Ar ea Lavatory

C C 3.20m
13.08m Powder Tubular
T & B H a l l w a y Blinds
1.50m
Room
Downstair
3.03m 11.10m
16
M ast e r' s 3.03m 11.10m
15
Living Area B e d r o o m 2ND F.F.L
14 14

13 13
4.60m 4.60m
12 12

11 11
O p e n
10 10 Tongue and Groove
9 9
B e l o w Plastered Finish
8 8
1.48m 1.48m 3.20m
7 7

6 6

B Upstair B B a l c o n y
5 5

3 2 1 4 3 2 1
1.73m F.F.L
2.40m 2.50m 2.40m 2.50m 0.40m
E n t r y N.G.L
Ramp
C a r p o r t
A 3.66m
A
3.62m 3.50m 3.03m 1.58m

11.72m
3.62m 3.50m 3.03m 1.58m A FRONT ELEVATION
A-02 A-02 SCALE 1:80mts
11.72m

A GROUND FLOOR PLAN A SECOND FLOOR PLAN


A-02 A-02 SCALE 1:100mts A-02 A-02 SCALE 1:100mts

A B C D D C B A

11.10m
11.10m

2.40m 4.60m 4.10m


4.10m 4.60m

APEX

1.30m 0.30m 0.30m 2.40m


1.30m
Tongue and Groove
Plastered Finish TOP OF ROOF BEAM

3.20m 3.20m 3.20m 3.20m


Aluminum Glass
Window

F i r e w a l l
Tongue and Groove
2ND F.F.L
Plastered Finish

3.20m 3.20m
2.92m 3.20m 3.20m
2.92m

F.F.L
0.40m 0.40m
0.40m N.G.L
0.40m

A RIGHT SIDE ELEVATION A LEFT S I DE ELEVAT I ON


A-02 A-02 SCALE 1:80mts
A-02 A-02 SCALE 1:80mts

PROJECT TITLE : OWNER : DESIGN BY SHEET CONTENTS


CONTRACTOR: REG. NO.: REVISIONS SHEET NO:
ALL MEASUREMENTS ARE TO BE VERIFIED ON SITE
DRAWN BY BY
TIN NO.: CONTRACTOR. ALL DISCREPANCIES
ARE TO BE IMMEDIATELY NO: DESCRIPTION DATE:
REPORTED TO ARCHITECTS &
7

A
PROJECT MANAGERS.

P.T.R. PROPOSED TWO STOREY CAD BY


CONTRACTOR ARE TO BE PREPARED & SUBMIT SHOP
6

CIVIL ENGINEER
RESIDENTIAL UNIT AS SHOWN DRAWING TO ARCHITECTS PRIOR TO COMMENCEMENT
OF WORKS. 5

23
ISSUED ON: CHECKED BY 4
THIS DRAWING, ACTING AS INSTRUMENT
OF SERVICE, IS THE PROPERTY OF 3
RECIO+CASAS,INC.. & CANNOT BE
PRODUCED WITHOUT THEIR WRITTEN CONSENT.
DATE DRAWN 2
ISSUED AT: SCALE AS SHOWN
ADDRESS : ADDRESS : DATE PRINTED - REPUBLIC ACT No. 545 1
4 3 2 1 1 2 3 4
11.72m
11.72m

3.62m 3.50m 4.60m


4.60m 3.50m 3.62m

APEX
APEX

SeeTruss
1.30m
1.30m Detail
0.69m
TOP OF ROOF BEAM
TOP OF ROOF BEAM

3.20m
3.20m 3.20m

T&B Bed r o om 2 Master's


Bedroom

2ND F.F.L
2ND F.F.L

L i v i ng A r ea
3.20m 3.20m Stair Up 3.20m
Parking

F.F.L
F.F.L
0.40m N.G.L 0.40m
N.G.L 0.40m

AREARELEVATION
A-02 A-02 SCALE 1:80mts

A LONGITUDINAL SECTION
A-02 A-02 SCALE 1:80mts

A B C D
SCHEDULE OF DOORS AND WINDOWS

11.10m
1.00m 0.90m 0.80m 0.60m 0.60m

2.40m 4.60m 4.10m

2.10m

D D
1.30m SeeTruss 0.30m
D
1
D
2
D
3 4 5

Detail PANEL DOOR PANEL DOOR FLUSH DOOR PVC DOOR SLIDING DOOR ( Aluminum)
SET (S) : 1 SET (S) : 3 SET (S) : 3 SET (S) : 2 SET (S) : 1
LOCATION: MAIN DOOR LOCATION: LAUNDRY, LANAI, LOCATION: MASTER BEDROOM, LOCATION: POWDER ROOM, LOCATION: MASTER BEDROOM
BALCONY BDRM1, BDRM2 COMMON T&B

3.20m 3.20m
Bedroom 2

1.35m 1.20m 2.00m 1.60m 0.80m 1.20m 0.60m 1.00m

0.60m 0.60m
1.20m 1.20m 1.20m
1.90m 1.96m
3.20m 3.20m
Living Area Kitchen 2.92m
Lanai W W W
2 3 4
SLIDING WINDOW (Aluminum Frame) SLIDING WINDOW (Aluminum Frame) SLIDING WINDOW (Aluminum Frame)
5.10m Reflected Glass Reflected Glass Reflected Glass
W W W W
SET (S) : 2 SET (S) : 3 SET (S) : 1 5 6 7 8
LOCATION: LIVING AREA,MASTER BEDROOM LOCATION: DINING AREA, BDRM 1, BDRM2 LOCATION: DINING AREA
FIX WINDOW (Aluminum Frame) SLIDING WINDOW (Aluminum Frame) SLIDING WINDOW (Aluminum Frame) FIX WINDOW (Aluminum Frame)
0.40m 0.40m Reflected Glass Reflected Glass Reflected Glass Reflected Glass
SET (S) : 2 SET (S) : 2 SET (S) : 2 SET (S) : 1
LOCATION: BACK DOOR, LANAI LOCATION: KITCHEN, TOILET & BATH LOCATION: POWDERED ROOM,TOILET & BATH LOCATION: STAIR

W
1
FIX WINDOW ( Aluminum Frame )

ACROSSSECTION Tempered Glass


SET (S) : 1
LOCATION: LIVING AREA , MASTER BEDROOM
A-02 A-02 SCALE 1:80mts

PROJECT TITLE : OWNER : DESIGN BY SHEET CONTENTS


CONTRACTOR: REG. NO.: REVISIONS SHEET NO:
ALL MEASUREMENTS ARE TO BE VERIFIED ON SITE
DRAWN BY BY
TIN NO.: CONTRACTOR. ALL DISCREPANCIES
ARE TO BE IMMEDIATELY NO: DESCRIPTION DATE:
REPORTED TO ARCHITECTS &
7

A
PROJECT MANAGERS.

P.T.R. PROPOSED TWO STOREY CAD BY


CONTRACTOR ARE TO BE PREPARED & SUBMIT SHOP
6

CIVIL ENGINEER
RESIDENTIAL UNIT AS SHOWN DRAWING TO ARCHITECTS PRIOR TO COMMENCEMENT
OF WORKS. 5

33
ISSUED ON: CHECKED BY 4
THIS DRAWING, ACTING AS INSTRUMENT
OF SERVICE, IS THE PROPERTY OF 3
RECIO+CASAS,INC.. & CANNOT BE
PRODUCED WITHOUT THEIR WRITTEN CONSENT.
DATE DRAWN 2
ISSUED AT: SCALE AS SHOWN
ADDRESS : n ADDRESS : DATE PRINTED - REPUBLIC ACT No. 545 1
1 2 3 4 1 2 3 4 1 2 3 4
11.72m 11.72m

3.62m 3.50m 4.60m 3.62m 3.50m 4.60m 11.72m

3.62m 3.50m 4.60m

E C3/F4
FTB
C3/F4
E B-3

1.98m FTB FTB 1.98m B-3 S-1 B-3

D C1/F2 FTB D B-1


B-1
B-1 D RB RB RB
FTB FTB
C2/F1 C2/F1 C1/F1

100mm THK. Slab on Fill


     
4.10m 4.10m S-1 S-1 B-1 4.10m RB RB
FTB FTB RB
FTB WF B-1 B-2 B-2 S-1 RB

C2/F3 C2/F1
C2/F2
C FTB FTB FTB
C B-1 B-2 B-2
C 8.70m
RB RB
13.08m C2/F3 13.08m
S-2 RB
WF WF
FTB B-3 B-1 RB RB
S-1
RB RB
4.60m FTB FTB FTB 4.60m B-1 S-1 B-2 4.60m
C1/F1 B-2

B-3
C1/F1 FTB
C1/F2 FTB FTB FTB B-1 RB
B B B-1 B-3 B RB
C1/F1 C1/F1
WF B-1 S-1 B-1 RB
2.40m FTB FTB 2.40m
B-1

C1/F2
A FTB
C1/F1
A B-1

S FOUNDATION PLAN S 2ND FLOOR FRAMING PLAN S ROOF BEAM PLAN


SCALE 1:100mts SCALE 1:100mts SCALE 1:100mts

 

D
150 MM THK SLAB ON GRADE
COMPACTED SUBGRADE
C1 C2 C3
100MM BASE COURSE 150 MM THK SLAB ON GRADE
150
VARIES
L

6MIL PE VAPOR BARRIER

D
D-10 TIES 1X50,R200
FOR COL. BAR SPLICES
TIE BEAM REINFORCEMENT SEE TABLE OF MIN. LAP
(SEE DETAIL)
SPLICE LENGTH OF COL.

COLUMN TIES AS
PER SCHEDULE
REINFORCEMENT
TIE BEAM

6 -D16 MAIN BARS


H

W W

 
TYP. TB SECTION

D
NTS
 

 
D

150MM THK CHB WITH


FOOTING REINFORCEMENT  
REINFORCEMENT

D
MARK W L D H REMARKS (SEE SCHED) BARS @ 600 O.C.
GRADE 60 150 MM THK
SLAB ON GRADE
F1 NOTES:
100MM COMPACTED
BASE COURSE 1. YIELD STRESS OF HOOPS = 40 KSI
F2 W
2. D = USE MAXIMUM COLUMN DIMENSION,
F3 1/6 CLEAR HEIGHT OR 18" (450mm)
WHICHEVER IS GREATER.

F4
 3. NUMBER OF HOOP TIES SAME AS PER
COLUMN TIES SCHEDULE.
WF 4. ALL CONCRETE REINFORCEMENT DETAIL
SHOULD BE DONE IN ACCORDANCE WITH
FOOTING DETAIL ACI DETAILING MANUAL 1980 PUB SP-66
5. THE CONTRACTOR SHALL NOTIFY THE ENGINEER
AFTER FOOTING EXCAVATION HAS BEEN COMPLETED,
NTS TO CONFIRM THE DESIGN SOIL BEARING CAPACITY.
FOOTING AND COLUMN TO BE ADJUSTED UPON
CONFIRMATION OF THE ACTUAL SOIL BEARING

TYP. WALL TO TIE BEAM CAPACITY.

CONNECTION DETAIL
NTS
COLUMN ELEV. SHOWING
DOWELS AND TIES SPACING DET.
NTS

PROJECT TITLE : OWNER : DESIGN BY SHEET CONTENTS


CONTRACTOR: REG. NO.: REVISIONS SHEET NO:
ALL MEASUREMENTS ARE TO BE VERIFIED ON SITE
DRAWN BY BY
TIN NO.: CONTRACTOR. ALL DISCREPANCIES
ARE TO BE IMMEDIATELY NO: DESCRIPTION DATE:
REPORTED TO ARCHITECTS &
PROJECT MANAGERS. 7

CIVIL ENGINEER
P.T.R. PROPOSED TWO STOREY
RESIDENTIAL UNIT
CAD BY

AS SHOWN
CONTRACTOR ARE TO BE PREPARED & SUBMIT SHOP
DRAWING TO ARCHITECTS PRIOR TO COMMENCEMENT
OF WORKS.
6

5 S
13
ISSUED ON: CHECKED BY 4
THIS DRAWING, ACTING AS INSTRUMENT
OF SERVICE, IS THE PROPERTY OF 3
RECIO+CASAS,INC.. & CANNOT BE
PRODUCED WITHOUT THEIR WRITTEN CONSENT.
DATE DRAWN 2
ISSUED AT: SCALE AS SHOWN
ADDRESS : ADDRESS : DATE PRINTED - REPUBLIC ACT No. 545 1
2L-A.B 2X2X14
0.30m
0.20m Top & Bot Chord 2l- A.B 11
2 x11
2 x 16
3
Web Member
11.75m

BEAM
1.11m

BEAM
9.68m

TRUSS-1 DETAIL
TYP. BEAM SECTION
NTS

2L-A.B 2X2X14
0.30m Top & Bot Chord 2l- A.B 11
2 x11
2 x 16
3
0.20m
Web Member
10.77m

BEAM
1.00m

BEAM
8.70m

TRUSS-2 DETAIL

2L-A.B 2X2X14
Top & Bot Chord 2l- A.B 11
2 x11
2 x 16
3

0.30m Web Member


0.20m
7.73m

BEAM
0.65m

BEAM
5.68m

TYP. BEAM ELEVATION TRUSS-3 DETAIL


NTS

SLAB SCHEDULE
30X1200X50MM
TANGILE

W 4X8X10

SLAB CONSTRUCTION NOTES


1. EDGE PANELS:
EXTEND TOP BARS OF ADJACENT INTERIOR PANEL AND
       
PROVIDE BOTTOM TEMPERATURE STEEL IN THE OPPOSITE
DIRECTION.

2. INTERIOR PANELS:
TYP. SLAB SECTION EXTEND TOP BARS OF ADJACENT PANELS AT LEAST L/4
OR MINIMUM DEVELOPMENT LENGTH WHICHEVER GREATER
NTS
AND PROVIDE BOTTOM TEMPERARUTRE STEEL IN BOTH DIRECTIONS.

TYP. STAIR DETAIL


NTS

PROJECT TITLE : OWNER : DESIGN BY SHEET CONTENTS


CONTRACTOR: REG. NO.: REVISIONS SHEET NO:
ALL MEASUREMENTS ARE TO BE VERIFIED ON SITE
DRAWN BY BY
TIN NO.: CONTRACTOR. ALL DISCREPANCIES
ARE TO BE IMMEDIATELY NO: DESCRIPTION DATE:
REPORTED TO ARCHITECTS &
PROJECT MANAGERS. 7

CIVIL ENGINEER
P.T.R. PROPOSED TWO STOREY
RESIDENTIAL UNIT
CAD BY

AS SHOWN
CONTRACTOR ARE TO BE PREPARED & SUBMIT SHOP
DRAWING TO ARCHITECTS PRIOR TO COMMENCEMENT
OF WORKS.
6

5 S
23
ISSUED ON: CHECKED BY 4
THIS DRAWING, ACTING AS INSTRUMENT
OF SERVICE, IS THE PROPERTY OF 3
RECIO+CASAS,INC.. & CANNOT BE
PRODUCED WITHOUT THEIR WRITTEN CONSENT.
DATE DRAWN 2
ISSUED AT: SCALE AS SHOWN
ADDRESS : ADDRESS : DATE PRINTED - REPUBLIC ACT No. 545 1
PROJECT TITLE : OWNER : DESIGN BY SHEET CONTENTS
CONTRACTOR: REG. NO.: REVISIONS SHEET NO:
ALL MEASUREMENTS ARE TO BE VERIFIED ON SITE
DRAWN BY BY
TIN NO.: CONTRACTOR. ALL DISCREPANCIES
ARE TO BE IMMEDIATELY NO: DESCRIPTION DATE:
REPORTED TO ARCHITECTS &
PROJECT MANAGERS. 7

CIVIL ENGINEER
P.T.R. PROPOSED TWO STOREY
RESIDENTIAL UNIT
CAD BY

AS SHOWN
CONTRACTOR ARE TO BE PREPARED & SUBMIT SHOP
DRAWING TO ARCHITECTS PRIOR TO COMMENCEMENT
OF WORKS.
6

5 S
33
ISSUED ON: CHECKED BY 4
THIS DRAWING, ACTING AS INSTRUMENT
OF SERVICE, IS THE PROPERTY OF 3
RECIO+CASAS,INC.. & CANNOT BE
PRODUCED WITHOUT THEIR WRITTEN CONSENT.
DATE DRAWN 2
ISSUED AT: SCALE AS SHOWN
ADDRESS : ADDRESS : DATE PRINTED - REPUBLIC ACT No. 545 1
1 2 3 4 1 2 3 4 1 2 3 4
11.72m
11.72m
3.62m 3.50m 4.60m
3.62m 3.50m 4.60m
3.62m 3.50m 4.60m
GENERAL NOTES AND SPECIFICATIONS:
E E 1. THIS ELECTRICAL INSTALLATIONS SHALL CONFORM WITH THE PROVISION OF THE P.E.C., THE REGULATIONS OF PASIG
AUTHORITIES AND THE REQUIREMENTS OF MERALCO.

2. POWER SUPPLY SHALL BE 230V, 1 PHASE, 2 WIRE, THERE SHALL BE ONLY ONE SERVICE DROP TO THE BUILDING.
1.98m 1.98m Lanai
h q
3. WIRING SHALL BE IN uPVC, UNLESS NOTED OTHERWISE, WIRES SHALL BE COPPER TYPE THHN MINIMUM SIZE SHALL BE 2.0
SQ.MM.
e n
WP
D Sh
D D 4. ALL METAL, NON- CURRENT CARRYING PARTS OF THE SYSTEM SHALL BE PROPERLY GROUNDED. A THIRD GROUNDING WIRE
SHALL BE PROVIDED FOR ALL BRANCH CIRCUIT RUNS.

5. ALL MATERIALS TO BE USED SHALL BE THE TYPES APPROVED FOR THE LOCATION AND PURPOSE.
g l 9
g p p l 3
Sl 6. THE ELECTRICAL INSTALLATION SHALL BE UNDER THE SUPERVISION OF A REGISTERED ELECTRICAL OR MASTER
1 ELECTRICIAN.
i
o m f MESSENGER WIRE
j f WP Range
4.10m i f 4.10m 4.10m Laundry Kitchen   

0.300 0.300
l d g Area
p
Sopq
p l l h Sefg e

Mirror
g g 8 SERVICE SPOOL PORCELAIN
DiningArea [ BY OWNER / MERALCO ]

Sij Ref CT METERING BOX


Sfg
2 Slmn Shi [ BY MERALCO ]
C Sde
C C TV
13.08m 13.08m Powder
k  
b b Room

VARIES ( CHECK HEIGHT )


k b b j j j
Sk Sk Srs
Sj16
c 11.10m
15 Sab
d
Scd
14 14
S(3way) 14
LivingArea
4.60m
13
a 4.60m
13
4.60m
13 KILO-WATTHOUR
METER
12
r r 12
a 12
[ BY MERALCO ]
m 11 11 11
Open
10 10 10

b Below
9
b 9 9
GROUNDING WIRE
8 8
b b 8
  
7 7 7 [ BY OWNER ]
Sabc 2 THHN [ BLACK COLOR ] +
6 6 6
21-30mm GRD.[ WHITE COLOR ]

1.800
B B c B     
GROUNDING WIRE
5 5 5
Smn [ WHITE COLOR ]
3 2 1 4 3 2 1 3 2 1
m [ LOOP AT GRND. ROD ]
S(3way)
NGL
2.40m 2.40m 2.40m Entry
n n s s

0.900
EARTHFILL
Carport

1.200
A A A

0.300
TO PANELBOARD "LP"
LOCATED INSIDE   
KITCHEN 3.0m LENGTH
EARTHFILL [ EMBEDDED ]

E GROUND FLOOR POWER LAYOUT


GROUND FLOOR LIGHTING LAYOUT SECOND FLOOR LIGHTING LAYOUT SCALE 1:100mts

SCALE 1:100mts SCALE 1:100mts

LOAD SCHEDULE & COMPUTATION ( PANEL BOARD 1 & 3 )


1 2 3 4
Circuit Quantity Load Circuit Protection Size of Wire Size of Conduit

3.62m 3.50m 4.60m


GENERAL NOTES No.
LOAD DESCRIPTION
LO CO Other
VA Volt
Amp Trip Frame Pole        
1 Lighting Outlet ( Ground Flr. ) 23 100 230 10 15AT 50AF 2   15mm
2 Lighting Outlet ( Second Flr. ) 33 100 230 14.35 15AT 50AF 2   15mm
E 1.ELECTRICAL INSTALLATION HEREIN SHALL BE DONE IN ACCORDANCE WITH 3 Convenience Outlet ( Ground Flr.) 13 180 230 10.17 15AT 50AF 2   15mm
1.98m
THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE & RULES AND 4 Convenience Outlet ( Second Flr.) 17 180 230 13.30 15AT 50AF 2   15mm
REGULATION OF THE MUNICIPALITY HAVING JURISDICTION. 5 1-ACU ( 2.0 HP) 1 3700 230 16.09 40AT 50AF 2   15mm
D ACU ACU
6 1-ACU ( 2.0 HP) 1 3700 230 16.09 40AT 50AF 2   15mm
Be d r o om 1
2. ALL ELECTRICAL WORKS HEREIN SHALL BE EXECUTED BY EXPERIENCED 7 1-ACU ( 2.0 HP) 1 3700 230 16.09 40AT 50AF 2   15mm
7
6 MEN UNDER THE DIRECT SUPERVISION OF A DULY LICENSED ELECTRICAL 8 REF ( 500 W ) 1 500 230 2.17 30AT 50AF 2   15mm
Bed r oom 2
ENGINEER OR A MASTER ELECTRICIAN, WORKS SHALL BE NEATLY PLACED, 9 RANGE 1 4000 230 17.39 30AT 50AF 2   15mm
4.10m
SECURELY FASTENED AND PROPERLY FINISHED.
TOTAL PB 56 30 5 16,160 115.65 70AT 150AT 2     25mm
Mirror

Lavatory 3. TYPE PF SERVICE ENTRANCE SHALL BE SINGLE PHASE, TWO WIRES, 230 V, 60 HZ.
C 4. ALL MATERIALS SHALL BE NEW & APPROVED TYPE FOR THE LOCATION AND PURPOSE. TOTAL LINE CURRENT ( AMPERE ):
13.08m
T&B Hallway 5 ACU

4
Downstair
IPB =[ (115.65 X 100%DF) + ( 25% X 17 ) ]
16

15
5. ALL INSTALLATION SHALL BE CONCEALED FROM BY INSTALLING CONDUCTOR =119.9 AMP
14

13 Master's IN PVC EMBEDDED IN CONCRETE, PARTITION OR CEILING. FEEDER CONDUCTOR            
4.60m
12 Bedroom
11
Open
10
Below 6. MINIMUM SIZE OF CONDUCTOR AND CONDUIT WHEN NOT INDICATED SHALL BE
9

8 1.6 mm DIA. ( NO. 14 ) AND 15 mm NOMINAL DIA. FOR CONDUIT RESPECTIVELY.


7

B Balcony
7. MOUNTING HEIGHT OF DEVICES SHALL BE AS FOLLOWS: LEGEND
5

4 3 2 1

2.40m A. PANEL BOARD - 1.80 m FROM TOP OF PANEL TO FFL PINLIGHT ACU
AIRCON OUTLET s3W 3-WAY SWITCH
B. WALL SWITCHES - 1.37 m ABOVE FINISH FLR LEVEL LIGHTING OUTLET 2-GANG WEATHERPROOF OUTLET TELEVISION OUTLET
WP
A C. CONVENIENCE OUTLET - 0.30 m ABOVE FIN FLOOR LEVEL TV

0.15 m ABOVE WORKING COUNTER PENDANT LIGHT CHANDELIER 1 CIRCUIT HOMERUN

LED STRIP LIGHT Sa SINGLE SWITCH PANEL BOARD


PB
2-GANG CONVENIENCE OUTLET Sab 2-GANG SWITCH Sabc 3-GANG SWITCH
E SECOND FLOOR POWER LAYOUT
SCALE 1:100mts

PROJECT TITLE : OWNER : DESIGN BY SHEET CONTENTS


CONTRACTOR: REG. NO.: REVISIONS SHEET NO:
ALL MEASUREMENTS ARE TO BE VERIFIED ON SITE
DRAWN BY BY
TIN NO.: CONTRACTOR. ALL DISCREPANCIES
ARE TO BE IMMEDIATELY NO: DESCRIPTION DATE:
REPORTED TO ARCHITECTS &
7

E
PROJECT MANAGERS.

P.T.R. PROPOSED TWO STOREY CAD BY


CONTRACTOR ARE TO BE PREPARED & SUBMIT SHOP
6

ELECTRICAL ENGINEER
RESIDENTIAL UNIT AS SHOWN DRAWING TO ARCHITECTS PRIOR TO COMMENCEMENT
OF WORKS. 5

11
ISSUED ON: CHECKED BY 4
THIS DRAWING, ACTING AS INSTRUMENT
OF SERVICE, IS THE PROPERTY OF 3
RECIO+CASAS,INC.. & CANNOT BE
PRODUCED WITHOUT THEIR WRITTEN CONSENT.
DATE DRAWN 2
ISSUED AT: SCALE AS SHOWN
ADDRESS : Brgy. Concepcion, Baliuag, Bulacan ADDRESS : Brgy. San Roque, San Rafael, Bulacan DATE PRINTED - REPUBLIC ACT No. 545 1
1 2 3 4 1 2 3 4
11.72m 11.72m

3.62m 3.50m 4.60m 3.62m 3.50m 4.60m

FD
E
1.98m WC
F

D RISER
D Lav
Lav
SH CO
PPR Pipe 1/2
4.10m 4.10m PVC Pipe 4"

CO

Mirror
S

Lav Lav TO SEWER LINE


F
F
Lav
C C SH
13.08m RISER

Lav Downstair
16
WC
11.10m HB
15

14

13
14

13
FD
4.60m 4.60m
12 12

11 11
Open ST
10 10

9 9
Below
8 8

7 7

6 6

B B Balcony
PVC Pipe 4" Lav
5 5

3 2 1 4 3 2 1

2.40m Entry 2.40m

S
TAPPED TO NEAREST WATERLINE

A A
PVC Pipe 4"

GROUND FLOOR SECOND FLOOR


P COLD WATER LAYOUT
SCALE 1:100mts
P COLD WATER LAYOUT
SCALE 1:100mts
ISOMETRIC VIEW CO

100mm DIA. PVC


DRAINAGE PIPE

1 2 3 4 1 2 3 4 GENERAL NOTES
TO SEWER LINE

11.72m 11.72m
1. ALL SANITARY WORKS SHALL CONFORM WITH THE PREVAILING REQUIREMENTS OF THE CONCRETE COVER
LOCAL ORDINANCES AND NATIONAL LAWS.
3.62m 3.50m 4.60m 3.62m 3.50m 4.60m
2. READ THE DRAWING IN CONNECTION WITH OTHER RELATED DRAWINGS AND SPECIFICATION
LEGEND THE ARCHITECT OR ENGINNEER SHALL BE NOTIFIED IF ANY DISCREPANCIES FOUND THEREIN.
4" THICK CONC.

E 3. THE CONTRACTOR SHALL DETERMINE THE ACTUAL LOCATION, DEPTH AND INVERT
ELEVATION OF EXISTING PIPES AND STRUCTURES TO CONFORME WITH THE
HOLLOW BLOCKS
TO MAIN CANAL

WC
WATER CLOSET CONCRETE COVER
ST PROPOSED SANITARY FACILITIES. PLAN
1.98m
LAV
LAVATORY 4. THE CONTRATOR SHALL BE RESPONSIBLE FOR ALLTHE WALL AND WINDOW OPENINGS.

CB CB CB FD
FLOOR DRAIN 5. ALL PIPES SHALL BE INSTALLED AS INDICATED. ANY RELOCATION REQUIRED FOR PROPER
D D KS
KITCHEN SINK
EXECUTION OF OTHER TRADES SHALL BE WITH PROPER APPROVAL OF THE ARCHITECT
OR ENGINEER. 100mm DIA. PVC
RISER DRAINAGE PIPE

FD CO
CLEAN OUT 6. ALL SLOPES FOR HORIZONTAL PIPES SHALL MAINTAIN 1% AS MIN. UNLESS OTHERWISE NOTED.

VSTR VENT STACK THRU ROOF 7. ALL FIXTURES SHALL BE VENTED UNLESS OTHERWISE NOTED.
4" THICK CONC.
WC S
STACK PIPE HOLLOW BLOCKS
4.10m 4.10m 8. REFER TO TECHNICAL SPECIFICATION FOR DETAILS AND EQUIPMENT SPECIFICATION. 2" THICK CONC.
SLAB

SECTION

Mirror
S CO
Lav Lav CATCH BASIN DETAILS
1SCALE
: 10 MM

C CO
C
13.08m RISER CO

Lav Downstair
FD WC 16
11.10m
15

14 14

13 13
4.60m 4.60m
12 12
LEACHING 1 FIN. GRADE LINE
11 11 3000
Open
10 10
Below 2000 1000

100
9 9

350
AIR SPACE
8 8 INLET
7 7
100mm PVC OUTLET
6 6 SANITARY TEE

750
B B Balcony 100mm PVC
SANITARY TEE
MANHOLE MANHOLE
5" THICK CONC.
HOLLOW BLOCKS
5 5

1500

1900
3 2 1 4 3 2 1 DIGESTION LEACHING
INLET

1250
CHAMBER CHAMBER
2.40m Entry 2.40m

750
MANHOLE 10mm HOR. BARS
PLASTER CEMENT FINISH
SPACED EVERY 2 LAYERS
OUTLET CONC. SLAB WITH 1Omm
CB REBARS AS SHOWN

200
A A LEACHING 2
10mm VERT. BARS
SPACED EVERY 0.80 M
4" THICK CONC. 10mm REBARS
HOLLOW BLOCKS SPACED AS SHOWN

LONGITUDINAL SECTION
SEPTIC VAULT PLAN 1
SCALE
: 30 MM

GROUND FLOOR SECOND FLOOR 1SCALE


: 30 MTS.

P SANITARY LAYOUT P SANITARY LAYOUT


SCALE 1:100mts SCALE 1:100mts

PROJECT TITLE : OWNER : DESIGN BY SHEET CONTENTS


CONTRACTOR: REG. NO.: REVISIONS SHEET NO:
ALL MEASUREMENTS ARE TO BE VERIFIED ON SITE
DRAWN BY BY
TIN NO.: CONTRACTOR. ALL DISCREPANCIES
ARE TO BE IMMEDIATELY NO: DESCRIPTION DATE:
REPORTED TO ARCHITECTS &
7

P
PROJECT MANAGERS.

P.T.R. PROPOSED TWO STOREY CAD BY


CONTRACTOR ARE TO BE PREPARED & SUBMIT SHOP
6

SANITARY ENGR./MASTER PUMBER


RESIDENTIAL UNIT AS SHOWN DRAWING TO ARCHITECTS PRIOR TO COMMENCEMENT
OF WORKS. 5

11
ISSUED ON: CHECKED BY 4
THIS DRAWING, ACTING AS INSTRUMENT
OF SERVICE, IS THE PROPERTY OF 3
RECIO+CASAS,INC.. & CANNOT BE
PRODUCED WITHOUT THEIR WRITTEN CONSENT.
DATE DRAWN 2
ISSUED AT: SCALE AS SHOWN
ADDRESS : Brgy. Concepcion, Baliuag, Bulacan ADDRESS : Brgy. San Roque, San Rafael, Bulacan DATE PRINTED - REPUBLIC ACT No. 545 1

You might also like