0% found this document useful (0 votes)
2 views

SDI-ISDB-T-User-Manual

The DVB-T Digital Encoder Modulator is designed for efficient HD signal processing from various sources, enabling long-distance transmission of multiple RF signals through a single coaxial cable. It features an LCD control panel for configuration and can be managed via a web interface. The device is suitable for use in hotels, stadiums, and broadcast environments, and includes safety instructions for proper installation and maintenance.

Uploaded by

Aquiles Vaesta
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2 views

SDI-ISDB-T-User-Manual

The DVB-T Digital Encoder Modulator is designed for efficient HD signal processing from various sources, enabling long-distance transmission of multiple RF signals through a single coaxial cable. It features an LCD control panel for configuration and can be managed via a web interface. The device is suitable for use in hotels, stadiums, and broadcast environments, and includes safety instructions for proper installation and maintenance.

Uploaded by

Aquiles Vaesta
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

DVB-T DIGITAL ENCODER MODULATOR

USER MANUAL

PLEASE READ THE MANUAL COMPLETELY BEFORE USE


l
ua
an
rM
se
U

GENERAL DESCRIPTION

The device is designed to make your HD device use more convenient, productive and cost efficient.
The Video-Audio devices can be from surveillance cameras, Blue-ray DVD, media-players, satellite
and terrestrial receivers or computers.

The device can do digital coding processing for HD-SDI/HDMI/CVBS signal with DTV technology.
The product adopts RF modulation technology characteristic to transmit the multiple RF signal through
one common coaxial cable for long distance transmission without amplification. The device can
distribute your HD source to HD resolution to an unlimited number of displays over almost any
distance. By adding DTV network mixer at the RF cable, you can easily achieve a large number
of displays or DTVs.

The device offer solution for such as hotels, stadiums, entertainment facilities, or broadcast
environments.

APPEARANCE INTRODUCE

Status & Power LED


Ethernet(NMS Control)
Directional keys
(up,down,left,right)

Enter Key

LCD Screen
ESC(Cancel/Return)

RF input
Power input

HDMI input

CVBS input 3G-SDI INPUT

RF output

1
l
ua
an
rM
se
U

LCD OPERATION INSTRUCTION

For setting configurations you can use the LCD control panel. The device will initialize to the main
interface after power on, and press “Enter” into the main menu.

Basic Setting

▲ ▲
Source Press key to select HDMI/SDI/CVBS
Standard DTV standard DVB-T

Freq(Frequency) Press ▲ ▲ ▲ key to move cursor and press
▲ ▲ ▲ ▲ to change numbers
Bandwidth Press key to select 6(default),7,8 MHZ
LCN Press key to edit
Service Name Shown service ID, Enter and set up to 15 alphanumeric characters
key to select MPEG-1 Layer2/AAC
▲ ▲

Audio Format Press


Network Enter to set the IP Address/Subnet Mask/ Default Gateway
Advanced Enter to set more TS setting
Theme Change the LCD background theme

Advance Setting
Press the “ENTER” to enter Advance menu. Then press the key to move the cursor edit bellow:

Service Provider Up to 15 alphanumeric characters


TSID 0000-65535
ONID 0000-65535
Network ID 0000-65535
Service ID 0000-65535

Use ▲ key to edit, 2-20 Mbps
▲ ▲

Bit rate
1080P conv. Output Config, select Auto or Interlace output
RF attenuation 0-30 attenuation selection
DVB-T ModeSet Set parameter Mode, FFT, GI, CR
PMT PID 32-8190
Video PID 32-8190
PCR PID 32-8190
Audio PID 32-8190
Default Reset to factory setting

Remark
● LCD turn off:10 seconds no using, LCD turn off automatically.
● Reset:Press ESC key 3 seconds to Restore factory settings.

2
l
ua
an
rM
se
U

WEB OPERATION INSTRUCTION

For setting configurations, you can use the LCD control panel and set by connecting the device
to a computer’s RJ45 Port. The default IP of device is 192 . 168 . 0 . 168 . Your computer will require
a static IP address in the range 192 . 168 . 0 . xxx except device’s; otherwise, it would cause an
IP conflict.

1. Computer static IP address Setting

2. Device set up and Log in


1、Connect the PC to the Ethernet port of the Device.
2、Launch the web browser and delete browsing history.
3、When log in to the IP (192.168.0.168), you will see the log in page.
The factory password is “admin”. Enter the password and click button “Apply”.

Also,user can changed the Username and Password by click “Change”, details display as following page.

3
l
ua
an
rM
se
U

3. General Section
In General section, you can change the settings as section “LCD OPERATION INSTRUCTION” description.

473000 6

4. Stream Section
In Stream section, you can change TS setting as section “LCD OPERATION INSTRUCTION” description.

473

4
l
ua
an
rM
se
U

5. Network Section
The default IP is 192.168.0.168. Allow user manual change in this page.

6. Update Section
Click “Update” on the left side of the homepage to display the following page.

Remark:
1、Make sure the network is stable before operation.
2、Avoid opening two pages with the same URL.
3、Avoid updating the FW & Main MCU through the router, which may cause the update to fail.
4、Ensures the route and power supply are not separated in the update process.
5、After the update, it takes a while for the device to automatically restart. And never turn off the
power supply during this period.
6、After the update, if the page does not automatically response, please do not power off, and
try to reload page, or use another browser to open again.
7、If the update doesn’t work properly, hold the reset button for 5 seconds before reloading the
web page.

6.1. Update LCD Module


1、Click “Update Modulator Firmware” button and pop up a dialog box.
2、Choose the file[xxx.bin] to be uploaded.
3、After the update is completed, it will automatically return to the settings page.

5
l
ua
an
rM
se
U

6.2. Update Modulator Firmware


1、Click “Update Modulator Firmware” button and pop up a dialog box.
2、Choose the file[xxx.v2img] to be uploaded.
3、After the update is completed, it will automatically return to the settings page.

6.3. Update Main MCU


1、Click “ Start Update Main MCU ” button, it will jump to another page as below picture.
2、Choose the file [xxx.bin] to upload then click “ Update ” button.
3、When update finished, will automatically return to homepage.

6
l
ua
an
rM
se
U

7. System Info Section


User can check the software version and Video sources information here.

7
l
ua
an
rM
se
U

SAFETY INSTRUCTIONS

CONNECTING TO THE MAINS SUPPLY


This product has to be connected to the mains supply.
Before carrying out maintenance operation or modification of the installation, the Device has to
be disconnected.
OVERVOLTAGE
An over-voltage cause short-circuits or fire. Never overload the power lines. Always use the 12VDC
power supply provided for single channel series.
LIQUIDS
should be protected from splashes;
Do not place objects filled with liquids on it;
If any liquid should accidentally fall into the cabinet, disconnect the power plug.
CLEANING
Disconnect the module before cleaning. Use only a humid cloth without solvent.
VENTILATION
the ventilation holes should not be obstructed;
not be installed in a hermetically sealed environment;
Other electronic products or heat producing items keep a minimum distance of 15 cm around the
apparatus for sufficient ventilation;
ACCESSORIES
Only use the supplied power adaptor;
The use of accessories not manufactured by the manufacturer can cause damage to the module.
INSTALLATION OF THE MODULE
Do not expose the unit to rain or moisture;
Do not installed in direct sunlight or in humid place;
Respect the minimum and maximum temperature specifications

PACKAGE CONTENT

Device 1pc
Power Adapter 1pc
User Manual 1pc

8
Ultra-High Definition
Digital Encoder Modulator

You might also like