Top Bar Extra Bar Top Bar Top Bar Extra Bar Extra Bar: B A B A D C C/D

The document outlines structural details for a proposed residential building, including specifications for beams, columns, and reinforcement bars. It emphasizes the importance of adhering to dimensions, material grades, and construction practices. General notes provide guidelines for construction and design considerations, ensuring compliance with engineering standards.

Uploaded by

sathish
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
5 views1 page

Top Bar Extra Bar Top Bar Top Bar Extra Bar Extra Bar: B A B A D C C/D

The document outlines structural details for a proposed residential building, including specifications for beams, columns, and reinforcement bars. It emphasizes the importance of adhering to dimensions, material grades, and construction practices. General notes provide guidelines for construction and design considerations, ensuring compliance with engineering standards.

Uploaded by

sathish
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

L L L

EXTRA BAR TOP BAR EXTRA BAR TOP BAR EXTRA BAR TOP BAR

D Ld Ld
d d

<50mm BOTTOM BAR <50mm <50mm BOTTOM BAR <50mm <50mm BOTTOM BAR

STIRRUPS NEAR STIRRUPS AT STIRRUPS NEAR STIRRUPS NEAR STIRRUPS AT STIRRUPS NEAR STIRRUPS NEAR STIRRUPS AT
SUPPORT MID SPAN SUPPORT SUPPORT MID SPAN SUPPORT SUPPORT MID SPAN

L/4 L/2 L/4 L/4 L/2 L/4 L/4 L/2

TYPICAL LONGITUDINAL SECTION OF BEAM

8d (≥ 75mm)

GRADE BEAM MAIN BEAM


SECONDARY BEAM

BEAM
Ld 4" 4"
1' 1'
1:5:10 P.C.C 4"
THK
4"
Ld COLUMN
TYPICAL PCC DETAIL FOR HANGER BARS TYPICAL DETAIL OF
FACE TYPICAL HANGER BAR DETAIL
GRADE / PLINTH BEAM 2-Y16 TRANSVERSE REINFORCEMENTS
(WHEN SECONDARY BEAM
TYPICAL BEAM-COLUMN CONNECTING TO MAIN BEAM)
CONNECTION DETAIL

DISTRIBUTION BARS AT TOP


0.3 L1 0.3 L2
CLOSER SPACING OF 0.1 L1 (MINIMUM TWO BARS)
STIRRUPS AT LAPPING 0.15 L1 0.15 L2
> Ld ZONE
0.5AS1 0.5AS2 AS2
c a
b c/d
a b d
P AS1 0 . 5 A S1
<P/2

0.15L1 0.25 L1 0.25 L2


Ld
L1 L2
≤ 4" INTERMEDIATE
EDGE CURTAILMENT OF SLAB REINFORCEMENT BEAM
LAP LENGTH AT LOCATIONS OF SPLICING OF
BEAM (BENT-UP BARS) M25
LONGITUDINAL BARS IN BEAM
FE500
GENERAL NOTES STRUCTURAL CONSULTANT: TITLE OF THE DRAWING:
1. ALL DIMENSIONS ARE IN FEET AND INCHES ONLY,UNLESS OTHERWISE MENTIONED. GENERAL NOTES DRAWING
2. DO NOT SCALE THE DRAWING, FOLLOW FIGURED DIMENSIONS ONLY. M.YUVARAJ, M.E.(Struct), AMIE, CEng (I),
3. THE STRUCTURE IS DESIGNED FOR GROUND+1 FLOOR AND DETAILED FOR GROUND
Y
Structural Engineer, NAME OF THE PROJECT:
FLOOR ONLY.
No.38, Prakasam Street, PROPOSED RESIDENTIAL BUILDING AT
4. BEFORE LAYING OF PCC (1:5:10, 4" THICK), LOOSE MATERIAL ON THE SURFACE TO BE
T.Nagar, Chennai - 600 017. SANKARI, SALEM
REMOVED.
Email ID: [email protected] DRG. NO.:
5. BASE OF EXCAVATED SURFACE SHALL BE COMPACTED THOROUGHLY AFTER WATERING.
CONTRACTOR: 2025/YSS/P60/GN
6. GRADE OF STEEL SHALL BE FE500 AND GRADE OF CONCRETE SHALL BE M25
7. LAP LENGTH SHALL BE 50 TIMES DIAMETER OF BAR SST BUILDING CONSTRUCTION & ROAD CONTRACTOR DATE 12.03.2025
8. CLEAR COVER FOR SHEET
Er. S.PRATHIP, BE (Civil), MBA A3
FOOTING : 50MM GRADE BEAM : 30MM DESIGN M.Y
Mobile : 99650 61000
COLUMN : 40MM FLOOR BEAM : 25MM DRAWN
Sankari, Salem I.P.K
FLOOR SLAB : 20MM REV. NO.
CLIENT: Gayathri Departmental Store APPROVED M.Y R0