The MINT I/O series by Masibus offers a range of cost-effective field interface modules for smart systems, including digital and analog input/output options. These modules support high-speed communication through Modbus RTU and Ethernet, making them suitable for various applications such as SCADA, building automation, and environmental monitoring. The MINT CP communication processor connects these I/Os to a Modnet Ethernet network, enhancing system monitoring and control capabilities.

Uploaded by

Naman Vachhani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views4 pages

MINT Intelligent IOs Communication Processor R5F - 0823

The MINT I/O series by Masibus offers a range of cost-effective field interface modules for smart systems, including digital and analog input/output options. These modules support high-speed communication through Modbus RTU and Ethernet, making them suitable for various applications such as SCADA, building automation, and environmental monitoring. The MINT CP communication processor connects these I/Os to a Modnet Ethernet network, enhancing system monitoring and control capabilities.

Uploaded by

Naman Vachhani
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

MINT Intelligent I/Os &

Communication Processor
DI-16 16-Channel Digital Input Module
DO-16 16-Channel Digital Output Module
AI-08 8-Channel Analog Input Module
AO-08 8-Channel Analog Output Module
MINT CP - Communication Processor
MINT IO Pair

Features
Masibus' MINT I/O series is the most cost effective field interface MINT I/O
module for smart systems whether it is DAS, SCADA, PLC or DCS. 2 Modbus serial ports RS-485
The MINT I/Os are available in universal 8 channel analog Input, 8 1 RS-485 + 1 Modbus over TCP/IP port - Modnet (Optional)
channel analog output, 16 channel digital input and 16 channel 2 masters can be connected at a time in MINT with 2 RS-485
digital output.
port option
Compact DIN-Rail enclosure
Using MINT I/Os supervisory system one can read remote process
values and events as well as communicate for process control. High-speed communication
These I/Os consist of powerful processors suited for high-speed Supports up to 15 clients on TCP/IP
communication and enhanced hardware features. LEDs for fault, communication and power

The MINT I/O family has Modbus RTU & Ethernet-Modnet port that MINT CP
integrates with same type of existing network in plant.
No. of Modbus serial slave devices supports on RS-485 - 15 max.
Modbus over Ethernet (Modnet) - 10/100Mbps- auto-detecting
MINT DI module has unique filter time selection feature for input
noise cancellation and debounce time feature to prevent extra Serial RS-485 (Protocol supported: Modbus RTU master)
events from a single contact closure. MINT DI can also store counter
input of frequency up to 1KHz. Free mINTPLUS Configuration Software
Configuration and diagnostics
MINT CP is a communication processor which connects MINT I/Os Online excel sheet logging
and any make of serial Modbus-RTU devices to a Modnet Ethernet
network.
Applications
mINT PLUS configuration software configures all communicating Pulse totalizing - Utility accounting
parameters in MINT series. Cost effective field interface to PLC/DCS
Remote I/Os for monitoring and control
The MINT series is best suited for processes that require reliable and SCADA
efficient control with high speed connectivity for system monitoring Security systems
and information exchange up to the corporate network.
Solar string monitoring
Building automation
Gas detection systems
Pipeline monitoring
Environmental monitoring
Infrastructure monitoring
Asset management

www.masibus.com [email protected]
TECHNICAL SPECIFICATIONS: MINT I/O RS485 - ETHERNET
AI-08 Module DO-16 Module
Input Specifications Output Specifications
No. of Channels 8 Open collector (External 24V DC required)
Output Type
E -200 °C to 1000 °C (Source or sink - factory set)
J -200 °C to 1200 °C Default/Pre-defined Value ON/ OFF
K -200 °C to 1350 °C Pulse Width 10msec.
T -200 °C to 400 °C 100mA per output
Thermocouple
B 450 °C to 1800 °C Maximum Current (Total current for output No.1 to 8 <500mA )
R 0 °C to 1750 °C (Total current for output No.9 to 16 <500mA )
S 0 °C to 1750 °C Vce ON 1.1V max.
N -200 °C to 1300 °C Status Indication
Pt100 (3 wire) -200 °C to 850 °C Power, module status, communication,
RTD Cu-53 -210 °C to 210 °C LEDs
Input channel status
NI-120 -80 °C to 210 °C Configuration Software
Types
Resistor Input Upto 2k Ω 0-2000
Configuration and diagnostics
mINT PLUS Software Online excel sheet logging
0/4 -20mA
Current -2000 to +20000 Logging time selectable : 1 to 65535 msec.
(Ext. 50Ω resistor)
Communication
0 to +10V -2000 to +20000 RS-485 Serial Port
0 to +100mV -2000 to +20000 Protocol Modbus-RTU slave
Voltage -10mV to +50mV -2000 to +20000 No. of Port 2 (1 optional)
0 to +250mV -2000 to +20000 Communication Speed (Baud
9600, 19200, 38400, 57600,115200 bps
0 to +5V -2000 to +20000 Rate)
Accuracy 0.1% of FS Parity ODD, EVEN ,NONE
T/C & voltage/current: 50mSec./channel Data Bits 8
Scan Rate Stop Bit 1, 2
RTD: 100mSec./channel
ADC Resolution 16 bit Default Settings 9600, 8 data bits, 1 stop bit, no parity
NMRR >60dB Connector Plug-in screw terminals, 1.5mm2 cable size
CMRR >120dB Recommended Cable Shielded, twisted pair, size: 0.14mm2
Temp-Co 100 ppm/°C Ethernet Port (Optional)
CJC Error ±2°C (0 to 55°C) Protocol Modbus TCP/IP (Modnet)
Input Impedance V, mV, TC >1 MΩ No. of Port 1
Sensor Burnout Current 0.5µA Speed 10/100 Mbps (auto-detecting)
RTD Excitation Current 250µA Maximum No. of Read Registers 1024
Max Voltage 20V DC Maximum No. of Write Registers 1024
Range Scaling Current/voltage inputs only Connector RJ45 (auto-crossover)
DI-16 Module No. of Clients Supported Up to 15
Input Specifications Power Supply
No of Channels 16 Power Supply 18 - 32VDC ±10%
Counter Frequency 1 KHz max. Power Consumption For I/O with only RS-485 < 3W
Counter Resolution 32 bit For I/O with ethernet < 5W
Counter Mode Up/Down Isolation
Pulse Width 500µSec. Supply to field: 1500VAC RMS
Filter Time (ms) 0 to 65535 msec. Supply to RS-485: 1500VAC RMS
De-bounce Time (ms) 0 to 65535 msec. Supply to ethernet: 1000VAC RMS
Chatter Filter Time 0 to 65535 msec. Physical
Chatter Filter Counts 1 to 250 events 101(H) x 22.5(W) x 120(D)
Input Impedance 2200 Ω for I/O with only RS-485
AO-08 Module Dimensions (in mm)
Output Specifications 101(H) x 48.5(W) x 120(D)
No. of Channels 8 for I/O with Ethernet
0-20mA/ 4-20mA @ 750 Ω max. Mounting DIN-Rail (35 mm)
Current (external 24V DC required) 160 gms approx. – For I/O with only RS-485
Output Weight
Types 0.05 -10/ 2-10 VDC @ 2KΩ min. 250 gms approx. – For I/O with Ethernet
Voltage
(external 24V DC required) Enclosure Material Molded ABS
DAC Resolution 16 bit Color Black
Accuracy 0.05% of FS Environmental
Temp-Co 100 ppm/°C Operating Temperature 0 to 55 °C
Storage Temperature -10 to 70 °C
Humidity 30 to 95 %RH non-condensing

www.masibus.com [email protected]
MINT CP MODULE
Performance Ethernet Port
Processor 32-bit CPU ARM core Protocol Modbus TCP/IP (Modnet)
Maximum No. of Read No. of Port 1
1024
Registers Speed 10/100 Mbps (auto-detecting)
Maximum No. of Write Connector RJ45 (auto-crossover)
1024
Registers Power Supply
Maximum No. of Modbus Logic Supply Voltage 18 - 32V DC
Commands Supported 100
Logic Supply Current 100mA max. @ 24VDC
No. of Slave Devices Power Consumption < 2.5W
No. of Modbus devices supports on serial port - 15
Supported per Serial Port Supply to RS-485: 1500V AC RMS
No. of Clients Supported Isolation Supply to Ethernet: 1000V AC RMS
Up to 15
on TCP/IP Physical
Configuration Software
Enclosure Material ABS plastic
mINT PLUS Software Configuration and diagnostics Mounting DIN-Rail (35 mm)
Communication Dimension (H x W x D) 101 mm x 22.5 mm x 120 mm
RS-485 Serial Port Color Black
Protocol Modbus-RTU slave Weight 160 g
No. of Port 2 Environmental
Communication Speed Operating Temperature
9600, 19200, 38400, 57600,115200 bps 0 ˚C to 55 ˚C
(Baud Rate)
Storage Temperature -10 ˚C to 70 ˚C
Parity ODD, EVEN, NONE
Humidity 30 to 95% RH non-condensing
Data Bits 8
Stop Bit 1, 2
Default Settings 9600, 8 data bits, 1 stop bit, no. parity
Connector Plug-in screw terminals, 1.5mm2 cable size
Recommended Cable Shielded, twisted pair, size: 0.14mm2
Ordering Code
MINT I/O
Model I/O Type AI Channel Type DO Type AO Type Communication
MINT XX X X X Port 1 Port 2
AI 8 channel analog input N None N None N None SS RS-485 RS-485
DI 16 channel digital input 8 Channel 0 Sink type I Current O/P SE RS-485 Ethernet
0
AO 8 channel analog output universal 1 Source type V Voltage O/P S0 RS-485 NA
DO 16 channel digital output 1 4 Channel Fix*
2 8 Channel Fix*
Note: *Fix - Current & Voltage

Model
MINT CP
Application

CONTROL ROOM

SCADA mINTPLUS

Ethernet Link
Serial RS232 Bus Ethernet Link

Ethernet Switch
PLC
Controller
RS-485/RS232
Converter

RS-485 Bus - 2
RS-485 Bus - 2

Ethernet Link
Ethernet Link

Com2-
RS-485

MINT CP MINT I/O WITH ETHERNET PORT

MINT I/O WITH RS485

www.masibus.com [email protected]
MINT IO PAIR
MINT IO Pair / Long Distance Signals for PLC/DCS System

Reproduces your Analog/Digital inputs from remote end to central PLC/DCS end upto 1200 meters apart
MINT pair solution cost will be 1/4 of the without pair solution
RS-485 MINT IO has two separate serial ports provides redundancy
Plug n play solution works with existing infrastructure on RS-485 link to save the field wiring cost

I/O Pair for Digital Input


Digital Input from field

Digital Input to PLC /


RS-485 RS-485

DCS Cards
Port -1 Port-1
Communication Redundancy Signal
Reproduced
RS-485 RS-485
Port-2 Port-2
2 wire cable
Upto 1200 meter

Digital Input 16 Channel Digital


Slave Pair Card Input Master Card

I/O Pair for Analog Input


Analog Input from field

Analog Input to PLC /


RS-485 RS-485

DCS Cards
Port-1 Port-1
Communication Redundancy Signal
Reproduced
RS-485 RS-485
Port-2 Port-2
2 wire cable
Upto 1200 meter

Analog Input 8 Channel Analog Input


Slave Pair Card Master Card

Ordering Code
MINT - Analog Input / Output - Master/Slave (RS-485)
Model AO Type
MINT AI/AO-MS X
I Current O/P
V Voltage O/P

MINT - Digital Input / Output - Master/Slave (RS-485)


Model DO Type
MINT DI/DO-MS X
0 Sink Type
1 Source Type

Head Office: Masibus Automation And Instrumentation Pvt. Ltd.


All specifications are subject to change without notice
B-30, GIDC Electronics Estate, Sector-25, Gandhinagar-382024, Gujarat, India.
due to continuous improvements.
Tel: +91 79 23287275-77, Fax: +91 79 23287281.
Doc. Ref. MINT I/Os - MINT CP/ R5F/0823
E-mail: [email protected], Web: www.masibus.com

You might also like