ALL COLUMN FOOTINGS AND TIE BEAMS SHALL REST ON 50mm THK. WELL COMPACTED GRAVEL BASE COURSE.
1. STANDARDS AND REFERENCES 3.3. BACK FILL SHALL BE PLACED IN LAYER AND EACH LAYER SHALL BE 200mm THK. AND SHALL BE
50 mm TOOLED
THE FOLLOWING SHALL GOVERN THE DESIGN, FABRICATION AND CONSTRUCTION OF THE PROJECT. COMPACTED TO 95% MAXIMUM DRY DENSITY. EDGES
1.1. NATIONAL STRUCTURAL CODE OF THE PHILIPPINES ( NSCP ) VOL. 1, 7TH EDITION. 2015. 3.4. WHERE LOOSE / SOFT MATERIAL ID ENCOUNTERED AT DEPTH OF EMBEDMENT INDICATED,
T
PLUS 12 DEPTH OF SOFT MATERIAL ON ALL SIDES WITH SELECT GRANULAR BACKFILL. COMPACT
2. DESIGN CRITERIA
SELECT GRANULAR BACKFILL TO 95% OF MAXIMUM DRY DENSITY.
2.1. LOADINGS
A. DEAD LOAD CONSTRUCTION
CONCRETE - 24.0 KN/M³ 4. MATERIALS JOINT
STEEL - 77.0 KN/M³ 4.1. CONCRETE 3 mm SAWED JOINT W/
150MM THK. CHB WALL - 2.97 KPA SEALANT
4.1.1. CONCRETE COVER OVER REINFORCING BARS SHALL BE AS FOLLOWS
100MM THK. CHB WALL - 2.84 KPA A. FOOTINGS, FOOTING-TIE BEAMS ( CAST AGAINST EARTH ) 75mm
T/2
B. LIVE LOAD B. BEAMS AND COLUMNS ( TO STIRRUPS AND TIES ) 40mm
T
ROOF - 1.00 kPa C. WALLS, SIDE OF FOOTING-TIE BEAMS ( CAST AGAINST FORMS ) 40mm
STALLS,TOILETS, FUNCTION HALL - 2.40 kPA D. SUSPENDED SLAB 20mm
CORRIDORS ABOVE, STAIRS - 3.80 KPA 4.1.2. BEFORE CONCRETE IS POURED, CHECK WITH ALL TRADES TO ENSURE PROPER PLACEMENT OF ALL WEAKEND PLANE
CORRIDORS ON GROUND, EXIT FACILITIES - 4.80 KPA OPENINGS, SLEEVES, CURBS, CONDUITS, ETC. RELATING TO THE WORK NOTE : JOINT
C. WIND LOAD (NSCP 2015) 4.2. REINFORCING BARS CONTROL JOINT CAN BE EITHER
CONSTRUCTION JOINT OR WEAKENED
BASIC WIND VELOCITY, V = 280 KPH 4.2.1. ALL REINFORCING BARS SHALL BE CLEAN OR RUST, GREASE OR OTHER MATERIALS THAT WILL IMPAIR PLANE JOINT.
P = qh [ (GCpf) - (GCpi) ] ( DESIGN WIND PRESSURE ) BOND.
WHERE :qh = VELOCITY PRESSURE, kPa 4.2.2. ALL REINFORCING BARS SHALL BE ACCURATELY AND SECURELY PLACED BEFORE POURING CONCRETE
GCpf = EXTERNAL PRESSURE COEFFICIENT
GCpi = INTERNAL PRESSURE COEFFICIENT
OR APPLYING MORTAR OR GROUT.
4.2.3. LAPPED SPLICES SHALL BE STAGGERED WHERE POSSIBLE.
CONSTRUCTION JOINT FOR SLAB
D. SEISMIC LOAD (NSCP 2010)
V = ( CVL / RT ) W ( DESIGN BASE SHEAR )
4.2.4. UNLESS OTHERWISE INDICATED. SPLICING OF REINFORCEMENT SHALL BE IN ACCORDANCE WITH
ACI-318M. EXCEPT THAT THE MINIMUM LAP SPLICE SHALL BE 40 BAR DIAMETER BUT NOT LESS THAN 600mm.
ON-FILL
d
VMAX = ( 2.50 CAL / R ) W VMIN = 0.11 CALW 4.2.5. UNLESS SHOWN OTHERWISE ON PLANS, SPLICES SHALL BE AS FOLLOWS:
12d
VMIN = (0.80 ZNVL / R) W (ZONE 4) A. INTERMEDIATE BEAMS; TOP BARS SHALL BE SPLICED AT MID-SPAN, AND BOTTOM BARS AT THE SUPPORT. 4d - 60mm Min.
D
WHERE : B. BEAMS FRAMING TO COLUMNS; TOP BARS SHALL BE SPLICED AT MID-SPAN AND BOTTOM BARS SHALL NOT
W = TOTAL DEAD LOAD BE SPLICED W/IN A DISTANCE OF TWICE THE MEMBER DEPTH FROM THE FACE OF THE COLUMN. THE
D
T = NATURAL PERIOD = CT ( HN ) 34 ; SPLICED LENGTH SHALL NOT BE LESS THAN 1.4 TIMES THE DEVELOPMENT LENGTH ( Ld ) IN 4.2.8 BELOW BUT 6
1
WHERE : NOT LESS THAN 600mm.
C = NUMERICAL COEFFICEINT C. COLUMNS; LAP SPLICES SHALL BE MADE WITHIN THE CENTER HALF OF HEIGHT AND THE SPLICE SHALL NOT 10d Min.
H = BUILDING HEIGHT BE LESS THAN 30 BAR DIAMETER. WELDING OR THE USE OF APPROVED MECHANICAL DEVICES MAY BE d d OFFSET
PERMITTED PROVIDED NOT MORE THAN ALTERNATE BARS ARE WELDED OR SPLICED AT ANY LEVEL AND THE
I = IMPORTANCE FACTOR = 1.00 MINIMUM VERTICAL DISTANCE BETWEEN TWO ADJACENT BAR SPLICES SHALL BE 600mm. 90 ° HOOK 180 ° HOOK
R = NUMERICAL FACTOR = 8.50 D. CHB WALLS; VERTICAL BARS SHALL BE SPLICED AT THE TOP OF WALL FOOTINGS OR FOOTING-TIE BEAMS
SEISMIC COEFFICIENT CV = 0.44Na AND AT THE BOTTOM OF REINFORCED CONCRETE LINTEL BEAMS OR BEAMS.
WIRE TIGHTLY TOGETHER
CA = 0.64NV 4.0.1. UNLESS OTHERWISE INDICATED: ALL BEAMS TERMINATING AT A COLUMN SHALL HAVE TOP AND BOTTOM TIE HOOK
4d - 600mm Minimum
NEAR SOURCE FACTOR ( 2.90 KM ) NV = 1.88 BARS EXTENDING TO THE FAR FACE OF THE COLUMN. TERMINATING IN A STANDARD 90 HOOK LENGTH OF
NA = 1.41 ANCHORAGE SHALL NOT BE LESS THAN 600mm.
Z = SEISMIC ZONE = 0.40 ( ZONE 4 ) 4.0.2. SHOP DRAWING FOR REINFORCEMENT SHALL BE SUBMITTED FOR APPROVAL OF THE ENGINEER PRIOR d
S = SOIL TYPE = D TO FABRICATION & INSTALLATION. NOTE :
4.0.3. DEVELOPMENT LEGTH ( Ld ) OF REINFORCING BARS SHALL BE AS FOLLOWS: 1. ALL BENDS SHOWN IN DETAILS / SCHEDULES SHALL LAP
BE SPLICE
2.1. DESIGN STRESSES SIZE OF REBARS DEVELOPMENT LENGTH
STANDARD HOOK OTHERWISE NOTED.
A. CONCRETE 10 mm 170 mm
COMPRESSIVE STRENGTH @ 28 DAYS fc' = 20.7 MPa ( 3,000 psi ) 12 mm 220 mm 2. 180° HOOKS MAY BE SUBSTITUTED FOR 90° HOOKS.
H/3
F. WELDS-USED E-60xx ELECTRODE 4.1.4. SHOP AND FIELD WELDING SHALL BE IN ACCORDANCE WITH AWS D1.1 AND PERFORMED BY QUALIFIED
G. STRUCTURAL BOLTS, ASTM-A307 4.1.5. UNLESS OTHERWISE INDICATED, WELDING ELECTRODES SHALL BE E60.
a. Ft = 96.60 MPa ( 14,000 psi ) b. Fv = 69 MPa ( 10,000 psi ) 4.1.6. NO STEEL SHALL BE FABRICATED OR ERECTED UNTIL SHOP DRAWINGS HAVE BEEN APPROVED BY THE
STRUCTURAL ENGINEER.
H/3
H
4.1.7. WELDS / ( CONFORM WITH AMERICAN WELDING STANDARDS ) USING E 60xx ELECTRODES. Fy = 93.77 MPa.
4.1.8. ANCHOR BOLTS ( CONFORM WITH ASTM A - 307 ) ft. = 96.60 MPa. fv = 69 MPa.
3. FOUNDATION 4.2. CONCRETE HOLLOW BLOCKS ( CHB ):
3.1. ASSUMED SOIL BEARING CAPACITY SHALL BE 96 kPa ( 2000 PSF )
4.2.1. UNLESS OTHERWISE INDICATED, CHB USED IN THIS WORK SHALL HAVE A MINIMUM ULTIMATE
3.1.1. IN CASE THERE ARE CHANGES ON THE LOCATION OF THE STRUCTURE AND THE ASSUMED DISTANCE
H/3
COMPRESSIVE STRENGTH f' m = 3.45 MPa ( 500 psi )
FROM THE SEISMIC SOURCE OF 2.90 KM NOTIFY THE ASSIGNED DISTRICT PROJECT ENGINEER AND THE PLANNING
4.2.2. ALL CHB CELL SHALL BE FILLED SOLIDLY WITH GROUT.
AND DESIGN UNIT FOR THE PROPER REVISION OF THE DESIGN. REFER TO THE SEISMIC SOURCE MAP PROVIDED IN
THE NATIONAL STRUCTURAL CODE OF THE PHILIPPINES OR PHIL.VOLCS. SEISMIC SOURCE MAP.
3.1.2. SOIL TEST SHALL BE CONDUCTED PRIOR TO START OF CONSTRUCTION.
5. CONSTRUCTION JOINT BEAM 75mm
REINFORCEMENT 3 EXTRA STIRRUPS @ 75mm ON
5.1. CONSTRUCTION JOINT NOT INDICATED ON THE PLANS SHALL BE MADE SO AS TO LEAST IMPAIR THE STRENGTH OF THE 75mm 75mm
3.1.3. IN CASE THE ACTUAL SOIL BEARING CAPACITY IS FOUND LESS THAN THE ASSUMED, 96 kPa; NOTIFY THE DO NOT INTERRUPT CENTER
STRUCTURE AND SHALL BE SUBJECT TO THE APPROVAL OF THE ENGINEER EXCEPT SLAB ON GRADE. 50mm
ASSIGNED DISTRICT PROJECT ENGINEER AND THE PLANNING AND DESIGN UNIT FOR THE PROPER REVISION OF THE 3 EXTRA STIRRUPS @ 75mm ON 75mm
DESIGN. 5.2. UNLESS SHOWN OTHERWISE, SLAB ON GRADE SHALL HAVE CONTROL JOINTS SPACED AT 600mm MAXIMUM CENTER TO CENTER 50mm
3.1.5. BOTTOM OF FOOTING SHALL BE AT LEAST 1.00m. BELOW NATURAL GRADE LINE. 5.3. BEAMS CONSTRUCTION JOINTS SHALL BE LOCATED WITH IN THE MIDDLE THIRD OF THE SPAN, IT SHALL BE PROVIDED
WITH 3 EXTRA STIRRUPS @ 75mm O.C. ON EACH SIDE OF THE JOINT.
3.1.6. SOIL BEARING CAPACITY SHALL BE INCREASED BY 33% WHEN IN COMBINATION WITH SEISMIC OR WIND
PREPARED: PRC. REG No.: 0048230 R.A. 9266 , SECTION 33 0126070 SHEET. NO.
PROJECT NAME AND LOCATION: SHEET CONTENTS: SUBMITTED: PRC No.:
INTELLECTUAL
IAOPOA No.: 45542
PROPERTY ACT 1892031
PTR No.: 2810827 All designs, drawings & specification PTR No.:
ABDUL MUHAYMEEN IMAM
prepared & furnished by the architect, are
instruments of the professional service,
and they are property of: Architect
CONSTRUCTION OF THREE (3) STOREY MIX-USE BUILDING CIVIL / STRUCTURAL ENGINEER S
DATE ISSUED: 03/08/2023
Whether the work for which they are made
maybe executed or not, are not to be
ALONG DIVERSION ROAD, BRGY. CASISANG, MALAYBALAY CITY, BUKIDNON
"AS SHOWN"
MRS. JOY S. CARALDE TIN No.:
703-212-270
1
TIN No.: 457-120-242 produced, copied or used on other works PROPONENT / CLIENT
except by written agreement by the
STRUCTURAL ENGINEER PLACE: MALAYBALAY CITY
ARCHITECT PLACE: MALAYBALAY CITY Architect & Engineer.