0% found this document useful (0 votes)
64 views11 pages

ScanFish Tropheus_EdgeTech 4205 setup and mobilisation

This document provides a comprehensive guide for the setup and mobilization of the ScanFish Tropheus with the EdgeTech 4205 sidescan sonar. It includes detailed instructions for hardware installation, such as the integration of a DC2DC converter junction box and the attachment of the sonar, as well as software integration steps for network configuration. Users are advised to refer to the respective manuals for operating details of the ScanFish and EdgeTech systems.

Uploaded by

adel202161
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
64 views11 pages

ScanFish Tropheus_EdgeTech 4205 setup and mobilisation

This document provides a comprehensive guide for the setup and mobilization of the ScanFish Tropheus with the EdgeTech 4205 sidescan sonar. It includes detailed instructions for hardware installation, such as the integration of a DC2DC converter junction box and the attachment of the sonar, as well as software integration steps for network configuration. Users are advised to refer to the respective manuals for operating details of the ScanFish and EdgeTech systems.

Uploaded by

adel202161
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

SCANFISH TROPHEUS

EDGETECH 4205 SETUP AND MOBILISATION

Last update: 31/01/2023


Version: 1.0
Contents

1 Introduction ..................................................................................................................... 3

2 Hardware installation ..................................................................................................... 3

3 Software integration ....................................................................................................... 9

ScanFish Tropheus_EdgeTech 4205 setup and mobilisation


Page 2 of 11
Last update: 31/1/2023
1 Introduction
This document guides the user through the setup and mobilisation of a ScanFish Tropheus
with an EdgeTech 4205 sidescan sonar. If the user needs details on how to operate the
ScanFish or details related to the EdgeTech configurations, we advise you to refer to their
respective manuals accordingly.

2 Hardware installation
To use a ScanFish with an EdgeTech 4205, a DC2DC converter junction box needs to be
installed in the ScanFish.

Figure 1 ScanFish Tropheus DC2DC junction box

The DC2DC junction box should replace the MUX, if you have this installed, otherwise it can
simply be installed in the top of the starboard side of the ScanFish. To install the box, first
remove the two locknuts labelled on the picture below. These are located on the starboard
side of the controller.

ScanFish Tropheus_EdgeTech 4205 setup and mobilisation


Page 3 of 11
Last update: 31/1/2023
Figure 2 The top shelf of the ScanFish skeleton seen from the underside on the starboard
side just next to where the controller is installed

Take the bolts out and put them into the same two holes from the opposite side and align
them with the two threaded holes from the underside of the DC2DC junction box as the
picture illustrates below. The bolts should be tight.

ScanFish Tropheus_EdgeTech 4205 setup and mobilisation


Page 4 of 11
Last update: 31/1/2023
Figure 3 The underside of the DC2DC junction box with two threaded holes for the mounting

The DC2DC serves the purpose of converting the 300 V DC output from bulkhead
connector number 8 on the port side of the ScanFish controller to a 24 V DC output for the
EdgeTech 4205 sidescan sonar.

Figure 4 Overview of ScanFish Tropheus controller with bulkhead connectors

ScanFish Tropheus_EdgeTech 4205 setup and mobilisation


Page 5 of 11
Last update: 31/1/2023
The Edgetech 4205 is attached to the ScanFish by an EdgeTech tow arm. The tow arm is
connected to the ScanFish tow point on the outside of the winch termination. No washers
are needed.

Figure 5 ScanFish tow point with winch cable termination and EdgeTech tow arm

Connect the tow arm with the Edgetech 4205 by a M12 shackle in the tow point.

ScanFish Tropheus_EdgeTech 4205 setup and mobilisation


Page 6 of 11
Last update: 31/1/2023
Figure 6 M12 shackle in the link between tow arm and EdgeTech tow point – Secure the
shackle pin with a tie wrap

The tow cable should be secured to the tow arm by tie wraps but remember to leave
enough slack so the moveable junctions of the tow arm can move freely.

ScanFish Tropheus_EdgeTech 4205 setup and mobilisation


Page 7 of 11
Last update: 31/1/2023
Figure 7 ScanFish Tropheus setup

In the case of a collision and breakage of the shear pin, the force will be transferred to the
safety cable, and to avoid the tow cable from snagging, the tow cable should be secured to
the safety cable and not directly to the tow cable connector via the tow point.

ScanFish Tropheus_EdgeTech 4205 setup and mobilisation


Page 8 of 11
Last update: 31/1/2023
Figure 8 A safe way of securing the tow cable

3 Software integration
On the ScanFish topside, the UHF connector should be connected with a deck cable to the
slip ring in the towing winch. The RJ-45 connector should be connected to the
ScanFish/EdgeTech control computer.

ScanFish Tropheus_EdgeTech 4205 setup and mobilisation


Page 9 of 11
Last update: 31/1/2023
Figure 9 Backside of the ScanFish topside. 1: AC power connector. 2: UHF connector with
cable to winch slip ring. 3: RJ-45 connector with LAN cable to ScanFish/Edgetech controller
computer

On the ScanFish/EdgeTech control computer, the IP addresses for the network connection
to the ScanFish and the EdgeTech 4205 should be configured. Do this by right clicking the
network connection, then clicking Properties > Internet Protocol Version 4 (TCP/IPv4) >
Properties as shown below. Type in an appropriate scope IP address for the ScanFish
under ’IP address:’ (eg 10.10.103.99) and click Advanced… > Add… and enter an
appropriate scope TCP/IP address under ’IP address:’ (eg 192.9.0.98) as shown below.

ScanFish Tropheus_EdgeTech 4205 setup and mobilisation


Page 10 of 11
Last update: 31/1/2023
Figure 10 Network connection setup steps

Turn the ScanFish topside on and under Settings > Options > Fish, type in the IP address
(10.10.103.XX, with XX being the last two digits on your ScanFish controller). A connection
can now be established and the EdgeTech Discover software can be launched.