ELEC-FINAL
ELEC-FINAL
A ARCHITECTURAL
A-1 EXTERIOR PERSPECTIVE
SITE DEVELOPMENT PLAN
LOCATION MAP District/City/Municipality
VICINITY MAP
N
ROOF FLOOR PLAN
CROSS SECTION
3294
294
LONGITUDINAL SECTION
7
S STRUCTURAL
3721 LINE & GRADE
S-1 STRUCTURAL GENERAL NOTES
S-2 TYPICAL COLUMN & BEAM DETAILS
S-3 FOUNDATION PLAN
3425 SECOND, THIRD FLOOR FRAMING PLAN
ROOF DECK FRAMING PLAN
1099
E ELECTRICAL
1038
ROAD 1231 E-1 ELECTRICAL GENERAL NOTES
5
1 GROUND, SECOND & THIRD FLOOR POWER
LAS
PINAS
TO NAGA
MONTESSORI ROAD LAYOUT
3
SCHOOL GROUND, SECOND & THIRD FLOOR LIGHTING
743
LAYOUT
8
GENERAL NOTES
LOAD SCHEDULE
LAS PINAS STRUCTURAL
RISER DIAGRAM
VERGONVILLE MONTESSORI
ELEMENTARY
SCHOOL SCHOOL
PULANG LUPA P PLUMBING & SANITARY
DOS BARANGAY
HALL
THE SITE P-1 GENERAL NOTES
GROUND, SECOND WATER SUPPLY LAYOUT
GROUND, SECOND SANITARY SUPPLY LAYOUT
ISOMETRIC WATER SUPPLY LAYOUT
ISOMETRIC SANITARY LAYOUT
9163
SEPTIC TANK, CATCH BASIN DETAILS SANITARY
FLOOR CLEANOUT DETAIL
CONCRETE CISTERN DIAGRAM
TO
ZAPOTE
ELECTRICAL
DIVINE LIGHT
VERGONVIILLE
ELEMENTARY SCHOOL
PULANG LUPA
DOS BARANGAY A101 SITE DEVELOPMENT PLAN
ACADEMY MGS HALL 1 1 : 50
CONSTRUCTION
INCORPORATED
LAS PINAS NORTH
DEPARTMENT OF NATIONAL HIGH SCHOOL
LABOR AND
EMPLOYMENT
VICINITY MAP TO
ALABANG
TO ALABANG-
ZAPOTE ROAD
LOCATION MAP MECHANICAL
DESIGNED BY: ALL DRAWINGS INCLUDING INITIAL DRAFTS ARE SUBJECT TO
PROJECT TITLE: SHEET CONTENT: PROJECT NO.:
CHANGE AS DEEMED NECESSARY. PROPOSED DRAWINGS ARE
INTELLECTUAL PROPERTIES OF eight94 studios inc. AND ARE
ALYSSA MARIZ C. INOCENTES, uap DEAN WILAN M. MALIGALIG, uap MR. GROSBIE SALVANIA & MS. FIONA SALVANIA & MR. NEFT SALVANIA INTENDED FOR PROJECT PROPOSAL PURPOSES & FOR THE EYES F
THE INTENDED RECIPIENT ONLY ANY DUPLICATION, IMITATION,
PROPOSED MULTI-DWELLING RESIDENTIAL BUILDING 2020-R1-001
eight94 studios ARCHITECT ARCHITECT OWNER
DISTRIBUTION TO UNINTENDED PERSON / ENTITIES, AS SHOWN
SHEET NO.:
Architectural Design Services
IMPLEMENTATION IN PART OR WHOLE OF THIS DRAFT, USE OF LOCATION: REFERENCE
THIS CLIENT'S REFERENCES FOR BENCH-MARKIN PURPOSES OR
A101
[email protected] PRC NO.: 40409 PTR NO.: 3883156 PRC NO.: 40410 PTR NO.: 6819009 GATHERING OF BIDS & QUOTATION FROM OTHER PART OR
WHOLE WITHOUT THE OFFICIAL CONSENT OF eight94 studios inc. VERGONVILLE, LAS PINAS MM
0906-063-6151 / 0927-129-1738 DATE ISSUED: 07 / 11 / 2017 DATE ISSUED: 01 / 07 / 2020 DATE ISSUED: 07 / 11 / 2017 DATE ISSUED: 01 / 16 / 2019 DRAWN BY: DWMM & AMCI CHECKED BY: DWMM & AMCI DESIGNED BY: DWMM & AMCI
SHALL BE SUBJECT TO CIVIL OR CRIMINAL LITIGATION SCALE: AS SHOWN
IAPOA NO.: PLACE ISSUED: BACOOR, CAVITE IAPOA NO.: 38011 PLACE ISSUED: LOS BAÑOS, LAGUNA APPROVED BY: DATE: 02 / 06 / 2020 REV. NO: 03
6
ARCHITECTURAL GENERAL NOTES
1 3'
A10
3 3
1. ALL DIMENSIONS SHALL BE VERIFIED ON SITE PRIOR
2 3
5263 4261 4261
5263 4261
5263 4261 IMPLEMENTATION.
5263
FIRE EXIT (DETAILS TO BE
PROVIDED BY SUPPLIER)
952 2863 3800 2861 9525 2. ALL CORRECTIONS AND/OR ADJUSTMENTS AS PER
A
SITE SITUATION SHALL BE APPROVED BY THE CLIENT
A A A
700
FIRE EXIT AND ARCHITECT PRIOR IMPLEMENTAION
836
1000
DROP
1000
1000
1000
FIRE EXIT
B B B B
W3 W3 W3 W3
W2 W2 W2 3. CONTRACTORS/SUB-CONTRACTORS SHALL SUBMIT
DETAILED SHOP DRAWINGS TO THE ARCHITECT FOR
2382
SERVICE AREA 9163
2613 2275 1375
STOCKROOM WATER
APPROVAL.
3 m²
417
TANK
BEDROO
5
BEDROOM 1 M2
4. MOUNTING LOCATION OF INDOOR AIRCON UNITS
MASTER BEDROO
3025
3025
3025
3025
2825
BEDROOM 6 m² M1 MASTER 7 m² AS WELL AS OUTDOOR CONDENSER UNITS SHALL BE
BEDROOM
SERVICE
8 m² 5 m² AREA VERIFIED ON SITE AND APPROVED BY THE ARCHITECT.
BEDROOM 1
W2
10 m²
622
5
6 m² W2
C C C C
2050 2298
D2 D2 D2 D2 D12
D3 D3 D13 D15
T
T&
&B
5
200
5
B
1400
KITCHEN
T&B
0
D18
3 m² 3 m²
3
DINING
4 m²
AREA
A103 DINING HALL
1700
AREA
EXTERIOR FINISH LEGEND
5257
UNIT UNIT B
D'
1255
1140
21 m²
5257
5257
5257
1
21 m²
4
W3
318
298
KITCHEN LIVING
2
A102 AREA LIVING LIVING DINING
A102 AREA AREA D17
AREA
WALL PAINT IN DARK GREY FINISH
2
A103
D D D
TO BE SELECTED BY THE CLIENT
D
D1 D1
D1
UP W1 UP W6 W5
W1 FUTURE
FUTURE
5 FUTURE
3
LIFT
LIFT
ALUMINUM WINDOW GLAZING
1703
1703
1703
177
177
LIFT
1703
PATHWAY PATHWAY
0
0
DN DN
A104
E E E E
377
FLOOR FINISH LEGEND
112
3
FAIR FACED CONCRETE IN
BI-FOLDING & MOVABLE PRIVACY BI-FOLDING & MOVABLE PRIVACY 1 NON-SKID FLOOR HARDENER
WITH CONSTRUCTION JOINTS
CLADDING, WITH RAILING CLADDING, WITH RAILING
7 6 7 6
A10
3
A103 A10
3
A10
3 2 NATURAL GRASS
PLAN A102 SECOND FLOOR A102 THIRD FLOOR A102 UPPER ROOF 3 TO
BE DISCUSSED
2 3' 3 1 2
TILES TO BE SELECTED BY
3'
THE CLIENT
2533
A
2432 2457 3325
B
WALL & COLUMN FINISH LEGEND
1 2
DRYWALL PARTITION
PARTITION DESIGN TO BE DISCUSS 200MM THICK PLASTERED CHB
B B
1249
DOUBLE SIZE BED STOCKROOM WATER TANK 150MM THICK PLASTERED CHB
QUEEN SIZE BED
100MM THICK PLASTERED CHB
2613 600 710 965 1375
NEW REINFORCED COLUMN -
2825
SERVICE AREA/LAUNDRY AREA
WALL MOUNTED TV
FAIR-FACED FINISH
1350
PC
1425
1450
3922
SINGLE SIZE BED
606
2825
600
BUILT-IN CLOSET
CEILING LEGEND
2476
675
C
CEILING LEVEL
BUILT-IN CLOSET
1475
1400
1375
600
775
920
C
1250 700 100 100 700 1498
2950MM FROM FIN. FLR LINE
2100
T&B
975
700
3188
CEILING LEVEL
HALL KITCHEN 3000MM FROM FIN. FLR LINE
857
1185
600
1900
2000
2100
ELECTRICAL LEGEND
600
1654
1849 1200
TV WALL
1249
10W COVE
915
1360
CL LIGHT
1700 772
1634
D'
15W FLUORESCENT
600 825 600
FL LIGHT
5057
2857
LIVING AREA
2700
1903
(FIXED)
3600
(DIRECTIONAL) LIGHT
835 2581 319 900 1228 1000 678
D
SL 6W SPOT LIGHT CH 50W
(SURFACE
1357
CHANDELIER
MOUNT)
885 900 500 2400 303 900 400 2600 351
775
6W TRACK CEILING
D D TL LIGHT FAN SMALL
ELECTRICAL
A102 UNIT A DETAILED FLOOR UNIT B DETAILED FLOOR A102 UNIT C DETAILED PLAN ELP
LIGHT POINTS CF 3 WING
A102 CEILING FAN
LAYOUT LAYOUT LAYOUT
5 1 : 50
6 1 : 50 7 1 : 50 W S 15W WALL
SCONCE
AS SHOWN
INTELLECTUAL PROPERTIES OF eight94 studios inc. AND ARE
ALYSSA MARIZ C. INOCENTES, uap DEAN WILAN M. MALIGALIG, uap MR. GROSBIE SALVANIA & MS. FIONA SALVANIA & MR. NEFT SALVANIA
INTENDED FOR PROJECT PROPOSAL PURPOSES & FOR THE EYES F PROPOSED MULTI-DWELLING RESIDENTIAL BUILDING 2020-R1-001
eight94 studios
Architectural Design
THE INTENDED RECIPIENT ONLY ANY DUPLICATION, IMITATION,
ARCHITECT ARCHITECT OWNER DISTRIBUTION TO UNINTENDED PERSON / ENTITIES,
Services
IMPLEMENTATION IN PART OR WHOLE OF THIS DRAFT, USE OF LOCATION: REFERENCE SHEET NO.:
eight94studios@gmail.
THIS CLIENT'S REFERENCES FOR BENCH-MARKIN PURPOSES OR
40409 PTR NO.: 3883156 PRC NO.: 40410 PTR NO.: 8116641
A102
PRC NO.: GATHERING OF BIDS & QUOTATION FROM OTHER PART OR
com
WHOLE WITHOUT THE OFFICIAL CONSENT OF eight94 studios inc.
DATE ISSUED: 07 / 11 / 2017 DATE ISSUED: 01 / 07 / 2020 DATE ISSUED: 07 / 11 / 2017 DATE ISSUED: 01 / 02 / 2020 CAD BY: DWMM & AMCI CHECKED BY: DWMM & AMCI DESIGNED BY: DWMM & VERGONVILLE, LAS PINAS MM
0906-063-6151 / 0927-129-
SHALL BE SUBJECT TO CIVIL OR CRIMINAL LITIGATION SCALE: AS SHOWN
IAPOA NO.: PLACE ISSUED: BACOOR, CAVITE IAPOA NO.: 38011 PLACE ISSUED: LOS BAÑOS, APPROVED BY: DATE: 02 / 06 / 2020 AMCI REV. NO: 03
1738
LAGUNA
GENERAL NOTES:
1. ALL ELECTRICAL WORKS SHALL BE DONE IN ACCORDANCE WITH THE PROVISION OF THE LATEST
EDITION OF THE PHILIPPINE ELECTRICAL CODE (PEC) EXISTING APPLICABLE ORDINANCES, RULES AND
REGULATION OF THE LOCAL GOVERNMENT AND WITH THE REQUIREMENT OF THE LOCAL POWER
COMPANY
B-02 2. SERVICE POWER SHALL BE SINGLE PHASE, 2WIRE, 230VOLTS, 60HZ, AC.
c
A-02 B-k
PLF PLF
f g c C-u C-u
A-l S-o PLF PLF HL PLF B-j C-s C-s
FL FL A-m PLD
WS
S-m
CF
PLF A-o B- S-
k
B-m
C-q CF
PLF
S-s
PLF 3. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SERVICE ENTRANCE FOR
l
A-m A-l A- B-j C-p CONNECTION TO POWER COMPANY SERVICE POINT.
p B-
l
f g HL P PLF PLF PLF PLF C-t CF C-03
C-
o S-l S-l C-u C-u
LF
A-j S-jk
PLD HL PLD PLF PLF C-m C- C-
A-i HL HL B- S-n k
m C-g
WS
PLF B-g i
5. UNLESS OTHERWISE INDICATED IN THE PLAN, ALL WIRINGS SHALL BE INSTALLED IN
PLD
d e
PLD
HL A-h HL
PLD
PLD
A-c PLF C- C-j
HL HL
B-f m C-m S-m
C-
HL STANDARD FLEXIBLE CONDUIT RUN EMBEDDED INSIDE CONCRETE AND HOLLOW BLOCKS STRUCTURES
k
COLUMNS
c FL FL A-f A-f B-e PLF
c PLF A-d HL PLF PLF PLF
B-c
C-b
PLF
C-
PLF
C-b WALL PARTITION SLABS AND OR RUN CONCEALED WALL WOODEN PARTITIONS AMD INSIDE THE
c
WS
Sabc
Sdef HL A-g B-e C-f CF CH C-e C-j WS
Sg PLF
A-c B-f B-
c C-b C-b
CEILING SPACES WHERE THE CONDUIT WIRING IS IMPRACTICABLE, SURFACE METAL MOULDING
d e HL
CF
A-e B-
PLF
C-d
PLF HL HL S-t WIRING MAY BE USED.
FL FL d
a
b
S-def S-def B-01 C2-01 SHALL BE INSTALLED AT
A-01 CONVENIENT AND INCONSPICUOUS LOCATIONS ALTHOUGH SUCH BOXES ARE SHOWN ON THE PLANS
C1-01
OR MENTIONED IN THE SPECIFICATIONS
7. ALL LIGHTING CIRCUIT HOMERNS AND CONVENIENCE OUTLETS SHALL BE WIRE WITH STD.
E101 GROUND LIGHTING SECOND LIGHTING THIRD LIGHTING UPPER ROOF LIGHTING THWN OR TW LIKEWISE ALL ELECTRICAL WIRES SHALL BE COLOR CODED.
E101 E101 E101
LAYOUT LAYOUT LAYOUT LAYOUT
1 1: 2 1: 3 1: 4 1: 8.ALL PINLIGHTS TO BE USED SHALL BE LED.
100 100 100 100
9.ALL NON-CURRENT CARRYING METAL PART O ELECTRICAL EQUIPMENT SHALL BE PROPERLY
B-06
GROUNDED IN ACCORDANCE WTH ARTICLE 2 50 PEC PART 1, 2009 EDITION.
W.P
A-06 D.P 10. ALL OUTLETS INSTALLED OUTSIDE THE BUILDING OR EXPOSED TO LIQUID (H2O) SHALL BE
D.P
B-07 WACU WACU
D.P WACU PROVIDED WITH GROUND FAULT CIRCUIT INTERUPTER (GFCI) IN COMPLIANT TO THE REQUIREMENTS.
D.P
WACU D.P C2-07
D.P
D.P
D.P D.P
W.P
W.P
D.P D.P
D.P
D.P
C2-02
W.P
RANGE 1.1
A-05
B-05 12. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE SUPERVISION
1.1
D.P
D.P
D.P
D.P
RANGE D.P
DATA & PH
DATA & PH
D.P
D.P
D.P
D.P
D.P
D.P
W.P
MDP MDP B-04
UP UP CL 10W COVE LIGHT PB PANEL BOX
LIFT W.P W.P W.P
A-03 B-03DN C2-01 15W FLUORESCENT LIGHT
DN FL DP DUPLEX CONVENIENCE OUTLET
C1-04 CATV BOX
TEL BOX
PLF 6W PIN LIGHT (FIXED)
UNIT A
PLD 5W DPU DUPLEX CONVENIENCE
PIN LIGHT (DIRECTIONAL)
CATV WITH USB OUTLET
TEL SL 6W SPOT LIGHT (SURFACE MOUNT) WEATHERPROOF DUPLEX
WP
INCOMING 230V, 1
6W TRACK LIGHT CONVENIENCE OUTLET
CONCRETE PEDESTAL 2W+G, 60HZ SYSTEM
FOR POWER &
AUXILIARY SERVICE
TL
ENTRANCE
ELECTRICAL LIGHT POINTS WH WATER HEATER
GROUND POWER & AUXILLIARY E101 THIRD POWER & AUXILLIARY
CONVENIENCE OUTLET
E101 E101 SECOND POWER & AUXILLIARY ELP
E101
GATHERING OF BIDS & QUOTATION FROM OTHER PART OR
0906-063-6151 / 0927-129-1738 WHOLE WITHOUT THE OFFICIAL CONSENT OF eight94 studios inc.
PTR NO.: DATE ISSUED: CAD BY: DWMM & AMCI CHECKED BY: DESIGNED BY:
SHALL BE SUBJECT TO CIVIL OR CRIMINAL LITIGATION VERGONVILLE, LAS PINAS MM SCALE: AS SHOWN
TIN NO.: PLACE ISSUED: APPROVED BY: DATE: 02 / 06 / 2020 REV. NO: 01
UNIT A - LOCATED @ KITCHEN UNIT B - LOCATED @ KITCHEN
CKT QUANTITY PROTECTION SIZE OF CIRCUIT HOMERUN CKT QUANTITY PROTECTION SIZE OF CIRCUIT HOMERUN
LOAD DESCRIPTION VA VOLTS AMPS LOAD DESCRIPTION VA VOLTS AMPS
NO. LO SW CO AT AF P KAIC (WIRES IN CONDUIT) NO. LO SW CO AT AF P KAIC (WIRES IN CONDUIT)
01 L.OUTLETS @ LIVING, KITCHEN, DINING, PATHWAY 11 4 - 1100 230V 4.78 15 100 2 10 2-2.0mm² TH in 15mm ∅ PVC 01 L.OUTLETS @ LIVING, KITCHEN, DINING, PATHWAY 10 4 - 1000 230V 4.34 15 100 2 10 2-2.0mm² TH in 15mm ∅ PVC
02 L.OUTLETS @ MASTER BEDROOM, BEDROOM 1 8 4 - 800 230V 3.48 02 L.OUTLETS @ MASTER BEDROOM, BEDROOM 1 7 3 - 700 230V 3.04
03 C.OUTLETS @ UNIT A - - 12 2160 230V 9.39 03 C.OUTLETS @ UNIT B - - 11 1980 230V 8.61
2-5.5mm2 THHN + 2.0mm2 2-5.5mm2 THHN + 2.0mm2
04 REFRIGERATOR @ KITCHEN - - 1 1500 230V 6.52 GROUNDING in 15mm ø PVC 04 REFRIGERATOR @ KITCHEN - - 1 1500 230V 6.52 GROUNDING in 15mm ø PVC
05 RANGE @ KITCHEN - - 1 3500 230V 15.22 05 RANGE @ KITCHEN - - 1 3500 230V 15.22
06 1HP WACU @ BEDROOM 1 - - 1 1840 230V 8.0 06 1HP WACU @ BEDROOM 1 - - 1 1840 230V 8.0
07 WATER HEATER 6KW - - 1 6000 230V 26.08 07 0.5HP WACU @ BEDROOM 2 - - 1 1000 230V 4.35
08 SPARE - - 1 2300 230V 10.0 08 SPARE - - 1 2300 230V 10.0
01 L.OUTLETS @ GROUND FLOOR PARKING AREA 19 3 - 258 230V 1.12 15 100 2 10 2-2.0mm² TH in 15mm ∅ PVC 01 L.OUTLETS @ LIVING, KITCHEN, DINING, PATHWAY 10 4 - 1000 230V 4.34 15 100 2 10 2-2.0mm² TH in 15mm ∅ PVC
02 C.OUTLETS @ GROUND FLOOR PARKING AREA - - 5 900 230V 3.91 2-5.5mm2 THHN + 2.0mm2 02 L.OUTLETS @ HALL, BEDRM 1, BEDRM 2, T&B 7 3 - 700 230V 3.04
GROUNDING in 15mm ø PVC
03 WASHING MACHINE - - 1 1500 230V 6.52 03 C.OUTLETS @ UNIT B - - 11 1980 230V 8.61
2-5.5mm2 THHN + 2.0mm2
04 LIFT 1.5KW - - 1 1500 230V 6.52 04 REFRIGERATOR @ KITCHEN - - 1 1500 230V 6.52 GROUNDING in 15mm ø PVC
05 1.5HP BOOSTER PUMP - - 1 3220 230V 14.0 05 RANGE @ KITCHEN - - 1 3500 230V 15.22
06 SPARE - - 1 2300 230V 10.0 06 1HP WACU @ BEDROOM 1 - - 1 1840 230V 8.0
TOTAL 25,140 230V 109.30 07 0.5HP WACU @ BEDROOM 2 - - 1 1000 230V 4.35
25,140 (0.80) 08 SPARE - - 1 2300 230V 10.0
I L @ 80% D.F = = 87.44 AMPERES USE : 2 - 30mm2 PHELPS DODGE THWN + 1 - 14mm2 TW (G) IN 25mm ø RSC
230
TOTAL 13,820 230V 60.09
13,820 (0.80)
I L @ 80% D.F = = 48.07 AMPERES USE : 2 - 30mm2 PHELPS DODGE THWN + 1 - 14mm2 TW (G) IN 25mm ø RSC
230
2 - 30mm2 PHELPS
DODGE THWN + 1 - 2 - 30mm2 PHELPS
14mm2 TW (G) IN DODGE THWN + 1 -
25mm ø RSC 14mm2 TW (G) IN
M 25mm ø RSC M
2P 2P
03 C.O 20AT 2P
03
20AT 2P
ELECTRICAL LEGENDS:
2P
30AT REF
04 C.O
2P
30AT REF
04
05 RANGE 30AT
05
30AT
2P
30AT WACU
06 RANGE
2P
30AT WACU
06 CL 10W COVE LIGHT PB PANEL BOX
20AT 20AT
07 WH
2P
07 WACU 2P 15W FLUORESCENT LIGHT
30AT SPARE
08 30AT SPARE
08 FL DP DUPLEX CONVENIENCE OUTLET
2P 2P
2P 2P
PLF 6W PIN LIGHT (FIXED)
GROUND GROUND DPU DUPLEX CONVENIENCE
PLD 5W PIN LIGHT (DIRECTIONAL)
WITH USB OUTLET
SL 6W SPOT LIGHT (SURFACE MOUNT) WEATHERPROOF DUPLEX
02 WP CONVENIENCE OUTLET
2 - 30mm2 PHELPS 2 - 30mm2 PHELPS 6W TRACK LIGHT
DODGE THWN + 1 - DODGE THWN + 1 - TL
14mm2 TW (G) IN 14mm2 TW (G) IN
ELECTRICAL LIGHT POINTS WATER HEATER
25mm ø RSC
M 25mm ø RSC
M WH
"UNIT C1 MDP" PANEL BOARD DETAIL