PPC WEEK NO 27th Week 2023

The test certificate for Zuari Cement Ltd's Portland Pozzolana Cement from the Solapur Grinding Unit indicates compliance with IS-1489(PART-1):2015 standards. Key results include a fineness of 328 M²/Kg, compressive strength values exceeding minimum requirements, and soundness parameters well within limits. The cement also meets chemical requirements, including a loss on ignition of 1.38% and a chloride content of 0.05%, confirming its quality and durability.

Uploaded by

vaibhavkpatil7
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
77 views1 page

PPC WEEK NO 27th Week 2023

The test certificate for Zuari Cement Ltd's Portland Pozzolana Cement from the Solapur Grinding Unit indicates compliance with IS-1489(PART-1):2015 standards. Key results include a fineness of 328 M²/Kg, compressive strength values exceeding minimum requirements, and soundness parameters well within limits. The cement also meets chemical requirements, including a loss on ignition of 1.38% and a chloride content of 0.05%, confirming its quality and durability.

Uploaded by

vaibhavkpatil7
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Zuari Cement Ltd

SOLAPUR GRINDING UNIT


SOLAPUR, MAHARASHTRA

ENGINEERED FOR DURABILITY

TEST CERTIFICATE Week No 43


PORTLAND POZZOLANA CEMENT Year 2024
SAMPLE RESULT OBTAINED REQUIREMENT
TEST TYPE FROM TEST IS-1489(PART-1):2015

PHYSICAL REQUIREMENTS
1. Fineness -Blaine(M²/Kg) 328 Not less than 300 M²/Kg
2.Soundness:

A.Autoclave Expansion (%) 0.036 Not more than 0.8 %


B.Le Chatelier Expansion (in mm) 1.00 Not more than 10 mm
3.Setting Time (in minutes)

A.Initial 155 Not less than 30 minutes


B.Final 225 Not more than 600 minutes
4.Compressive Strength (MPa)

A.72 ± 1 hr.(3 days) 25.4 Not Less than 16 MPa


B.168 ± 2 hr.(7 days) 35.0 Not Less than 22 MPa
C.672 ± 4 hr.(28 days) 53.0 Not Less than 33 MPa
5.Dry Shrinkage % UT Not more than 0.15 %
CHEMICAL REQUIREMENTS
1.Loss on Ignition (% by mass) 1.38 5 % Maximum
2.Insoluble Residue (% by mass)

A.Max 32.80 x+4(100-x)/100


B.Min x*0.6

where x is the declared % Fly ash in the given


Portland Pozzolana Cement

1.27
3.Magnesium Oxide (MgO) (% by mass) 6.0 % Maximum

2.10
4.Total Sulphur content calculated as (SO3) (% by mass) 3.5 % Maximum

5.Chlorides (% by mass) 0.05 0.10 % Maximum


6.Declared % Fly Ash 0 15.0% TO 35.0 %
35.0
0

Water required for paste of standard consistency (%)


Water required for paste of standard
29.50
30.70
consistency (%)
The above
The above cement
cement complies
compiles with
with the
the requirements
requirements of
of IS
IS 1489(PART-1)
1489(PART-1) :: 2015 For PORTLAND
PORTLAND POZZOLANA
POZZOLANA CEMENT

Computer generated Report, hence Signature is not For Zuari Cement


required Ltd
For BIS certification details see website MANAGER (QC)

You might also like