0% found this document useful (0 votes)
14 views24 pages

S5391 - Relay Selection Guide 15-10-10

The Relay Selection Guide provides an overview of various numerical protection relays for power systems, detailing their specifications and applications. It includes models for feeder, motor, and transformer protection, highlighting features such as communication interfaces, data storage, and monitoring functions. The guide serves as a comprehensive resource for selecting appropriate relays to enhance protection and efficiency in electrical networks.

Uploaded by

satyajit_naib
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views24 pages

S5391 - Relay Selection Guide 15-10-10

The Relay Selection Guide provides an overview of various numerical protection relays for power systems, detailing their specifications and applications. It includes models for feeder, motor, and transformer protection, highlighting features such as communication interfaces, data storage, and monitoring functions. The guide serves as a comprehensive resource for selecting appropriate relays to enhance protection and efficiency in electrical networks.

Uploaded by

satyajit_naib
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

Better protection and more efficiency

for your power system

Relay Selection Guide


Version 1.0

Answers for energy. s


Siemens Ltd. MRP Eff. April 02, 2010.   1
Relay Selection Guide - Version 1.0

INDEX

S.NO. MAIN PROTECTION MODEL PAGE

01 Numerical Feeder Protection


NON DIRECTIONAL 2 STAGE OVERCURRENT AND EARTH FAULT RELAY 7SJ45, 7SJ46 3

COMPACT NON DIRECTIONAL OVERCURRENT AND EARTH FAULT PROTECTION RELAY 7SR11 - Type A 4

NON DIRECTIONAL OVERCURRENT, MOTOR AND OVERLOAD PROTECTION RELAY 7SJ600 5

COMPACT NON DIRECTIONAL OVERCURRENT AND EARTH FAULT PROTECTION RELAY 7SR11 6

NON DIRECTIONAL OVERCURRENT, MOTOR AND OVERLOAD PROTECTION RELAY 7SJ602 7

COMPACT DIRECTIONAL OVERCURRENT AND EARTH FAULT PROTECTION RELAY 7SR12 8

MULTIFUNCTION NON DIRECTIONAL OVERCURRENT RELAY 7SJ61 9

MULTIFUNCTION NON DIRECTIONAL OVERCURRENT RELAY 7SR21 10

MULTIFUNCTION DIRECTIONAL OVERCURRENT RELAY 7SR22 11

COMPACT MULTIFUNCTION NON DIRECTIONAL/ DIRECTIONAL OVERCURRENT RELAY 7SJ80 12

MULTIFUNCTION DIRECTIONAL OVERCURRENT RELAY 7SJ62 13

MULTIFUNCTION DIRECTIONAL OVERCURRENT RELAY 7SJ63 14

02 Numerical Motor Protection


NON DIRECTIONAL OVERCURRENT, MOTOR AND OVERLOAD PROTECTION RELAY 7SJ600 15

NON DIRECTIONAL OVERCURRENT, MOTOR AND OVERLOAD PROTECTION RELAY 7SJ602 16

COMPREHENSIVE MOTOR PROTECTION RELAY 7SG17 17

MULTIFUNCTION MOTOR PROTECTION RELAY 7SK80 18

MULTIFUNCTION MOTOR PROTECTION RELAY 7SJ61, 7SJ62, 9, 13,


7SJ63 14

03 Numerical Transformer Protection


MULTIFUNCTION TRANSFORMER PROTECTION RELAY 7SR242 19

MULTIFUNCTION INTEGRATED TRANSFORMER PROTECTION RELAY 7UT612 20

MULTIFUNCTION TRANSFORMER PROTECTION RELAY 7SG14 21

MULTIFUNCTION INTEGRATED TRANSFORMER PROTECTION RELAY 7UT613 22

2
Relay Selection Guide - Version 1.0

Numerical Feeder Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

50/51, 50N/51N The 7SJ45 is a numerical overcurrent protection relay which is 7SJ45
primarily intended as a radial feeder or transformer protection
(backup) in electrical networks. It provides definite-time and inverse-
time overcurrent protection according to IEC and ANSI standards. The
7SJ45 relay does not require auxiliary voltage supply. It imports its
power supply from the current transformers.

- 2-stage O/C protection with DT or IDMT (IEC/ANSI) tripping


characteristic

- Operation w/o auxiliary voltage via integrated CT powered power


supply

- Standard CT inputs (1 A / 5 A)

- Low power CT required only (ca. 1,4 VA at IN)

- Tripping with impulse output (24 V DC / 0,1 Ws) or conventional


tripping relay (changeover contact) and auxiliary tripping CT

- Trip impulse repetition for CB failure conditions (for devices with


impulse output)

- Integrated mechanical trip indication optionally

50/51, 50N/51N The 7SJ46 is a numerical overcurrent protection relay which is 7SJ46
primarily intended as a radial feeder or transformer protection
(backup) in electrical networks. It provides definite-time and inverse-
time overcurrent protection according to IEC and ANSI standards.
The 7SJ46 relay has an AC and DC auxiliary power supply with a wide
range allowing a high degree of flexibility in its application

- 2-stage O/C protection with DT or IDMT (IEC/ANSI) tripping


characteristic

- Universal application due to integrated wide range AC/DC power


supply.

- Standard CT inputs (1 A / 5 A)

- Low power CT required

- Tripping with impulse output (24 V DC / 0,1 Ws) or conventional


tripping relay (changeover contact) and auxiliary tripping CT

- Trip impulse repetition for CB failure conditions

- Integrated mechanical trip indication

- One live contact for monitoring

3
Relay Selection Guide - Version 1.0

Numerical Feeder Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

46BC, 50, 50G/N, The Argus C Type A is a numerical overcurrent protection relay 7SR11-
50BF, 51,51G/N, intended for use on distribution and industrial networks. It provides Type A
a basic overcurrent function aimed at reducing engineering time by
64H, 60CTS,
reducing complexity. Communication access to the relay functionality
74TCS, is via a front USB port for local PC connection or rear electrical RS485
86 port for remote connection.
Features
- Four Settings Groups
- Password Protection
- User Programmable Logic
- Self Monitoring
- Circuit Breaker Trip and Maintenance Counter
- Trip Timers

User Interface
- 20 Character x 4 Line Backlit LCD
- Menu Navigation Keys
- 9 User Programmable Tri-colour LEDs
- User Language Configuration

Communication Interface
- Front USB port + Rear RS485 port
- Protocols - IEC60870-5-103, DNP3.0 or Modbus RTU (User
Selectable at site)
- Time Synchronism
- Viewing and Changing Settings

Data Storage
- 1000 events are stored and time tagged to 1ms resolution.
- Event Records User Configurable
- Last 10 fault records with time and date of trip, measured
quantities and type of fault.
- 10 waveform records of 1 second duration

Monitoring Functions
- Primary/Secondary Current Phases and Earth
- Positive Phase Sequence (PPS) Current
- Negative Phase Sequence (NPS) Current

Hardware
- 4 CT Inputs
- 3 binary inputs and 5 binary outputs
- Auxiliary Supply 80 to 250V DC or 24 to 60V DC

4
Relay Selection Guide - Version 1.0

Numerical Feeder Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

50, 50N, 51, The 7SJ600 is a numerical overcurrent relay which, in addition to its 7SJ600
51N, 46, 49, primary use in radial distribution networks and motor protection, can
also be employed as backup for feeder, transformer and generator
14/ 48, 74 TC,
differential protection
51C
Features
- DT/IDMT: I>, IE>>, I>>>; Ie>, le>> / lp>, lEp>
79M (Optional)
- Motor protection
o Overload protection
o Unbalance load protection
o Start-up monitoring
- Reverse Interlocking
- Trip circuit supervision
- Cold load pickup (e.g. for energising transformers)

User Interface
- Control via keyboard
- 6 LEDs (4 are independently programmable)
- User Friendly and keys for front operation

Communication Interface
- Serial interface with IEC-protocol / DIGSI V3
Or DIGSI 4 (≥ 4.3)
- Via RS232 – RS485 converter
- Via modem
- IEC 60870-5-103 protocol, 2 kV-isolated
- RS485 interface

Data Storage
- Fault event logging with time stamp (buffered)
- 8 oscillographic fault records

Monitoring Functions
- Primary/Secondary Current Phases and Earth

Hardware
- 2 Alarm relays (independently programmable)
- 3 Binary inputs (independently programmable)
- 2 Trip contacts with 2 making contacts each
(independently programmable)
- OPEN/CLOSE test power circuit breaker
- 3 CT Inputs : 1A or 5A (selectable via Jumper)
- Auxiliary voltage: D.C. 60 - 125V, 110 - 250 V / A.C. 115 V (via
Jumper), D.C. 24/48 V, A.C. 230 V
- 1 Live Status contact

5
Relay Selection Guide - Version 1.0

Numerical Feeder Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

37, 46BC, The 7SR11 is overcurrent protection relay developed to enhance the 7SR11
46NPS,49, 50 Argus family of products by providing a familiar product using the
latest generation of hardware technology.The 7SR11 overcurrent and
50G/N/SEF, 50BF,
earth fault relays are available in single and four pole variants.
51, 51G/N/SEF,
Features
64H, 81HBL2,
- Four Settings Groups
74TC, 60CTS, 86,
- Password Protection
51C
- User Programmable Logic
- Self Monitoring
Optional
79 - Circuit Breaker Trip and Maintenance Counter
- Trip Timers

User Interface
- 20 Character x 4 Line Backlit LCD
- Menu Navigation Keys
- 9 User Programmable Tri-colour LEDs
- User Language Configuration

Communication Interface
- Front USB port + Rear RS485 port
- Protocols - IEC60870-5-103, DNP3.0 or Modbus RTU (User
Selectable at site)
- Time Synchronism
- Viewing and Changing Settings

Data Storage
- 1000 events are stored and time tagged to 1ms resolution.
- Event Records User Configurable
- Last 10 fault records with time and date of trip, measured
quantities and type of fault.
- 10 waveform records of 1 second duration

Monitoring Functions
- Primary/Secondary Current Phases and Earth
- Positive Phase Sequence (PPS) Current
- Negative Phase Sequence (NPS) Current

Hardware
- 1 CT 3 Binary Inputs 5 Binary Outputs
- 4 CT 3 Binary Inputs 5 Binary Outputs
- 4 CT 6 Binary Inputs 8 Binary Outputs
- Auxiliary Supply 80 to 250V DC or 24 to 60V DC

6
Relay Selection Guide - Version 1.0

Numerical Feeder Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

50, 50N, 51, The 7SJ602 is a numerical overcurrent relay which, in addition to its 7SJ602
51N, 46, 49, primary use in radial distribution networks and motor protection, can
also be employed as backup for feeder, transformer and generator
74 TC, 50BF
differential protection
Features
Optional
- DT/IDMT: I>, l>>, l>>>; lE>, IE>> / lp>, IEp>, IEE>, LEE>>, IEEp>
79M, 50Ns,
- Motor protection
51Ns, 64, 67Ns,
o Overload protection
14/ 48, 37, 66/86
o Unbalance load protection
o Start-up monitoring
- Reverse Interlocking
- Trip circuit supervision
- Cold load pickup (e.g. for energising transformers)
- Displacement voltage
- Disk emulation

User Interface
- Control via keyboard
- 6 LEDs (4 are independently programmable)
- User Friendly and keys for front operation

Communication Interface
- Serial interface with IEC-protocol / DIGSI V3
Or DIGSI 4 (≥ 4.3)
- Via RS232 – RS485 converter
- Via modem
- IEC 60870-5-103 protocol, 2 kV-isolated
- RS485 interface

Data Storage
- Fault event logging with time stamp (buffered)
- 8 oscillographic fault records

Monitoring Functions
- Operational measured values I, V
- Power measurement P, Q, S, Wp, Wq
- Slave pointer
- Mean values

Hardware
- 4 current transformers or
- 3 current + 1 voltage transformers
- 3 binary inputs
- 4 output relays
- CT Inputs 1A or 5A (selectable via Jumper)
- Auxiliary voltage: D.C. 60 - 125V, 110 - 250 V / A.C. 115 V (via
Jumper), D.C. 24/48 V, A.C. 230 V
- 1 Live Status contact

7
Relay Selection Guide - Version 1.0

Numerical Feeder Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

37, 46BC, The 7SR12 is overcurrent protection relay developed to enhance the 7SR12
46NPS,49, 50 Argus family of products by providing a familiar product using the
latest generation of hardware technology.The 7SR12 overcurrent
50G/N/SEF, 50BF,
and earth fault directional relays are available in single and four pole
51, 51G/N/SEF, variants.
64H, 81HBL2,
Features
74TC, 60CTS,
- Four Settings Groups
86, 27/59, 47,
- Password Protection
51V, 59N, 67/50,
- User Programmable Logic
67/50G/N, 67/51,
- Self Monitoring
67/51G/N, 51C,
- Circuit Breaker Trip and Maintenance Counter
60VTS
- Trip Timers

Optional User Interface


79 - 20 Character x 4 Line Backlit LCD
- Menu Navigation Keys
- 9 User Programmable Tri-colour LEDs
- User Language Configuration

Communication Interface
- Front USB port + Rear RS485 port
- Protocols - IEC60870-5-103, DNP3.0 or Modbus RTU (User
Selectable at site)
- Time Synchronism
- Viewing and Changing Settings

Data Storage
- 1000 events are stored and time tagged to 1ms resolution.
- Event Records User Configurable
- Last 10 fault records with time and date of trip, measured
quantities and type of fault.
- 10 waveform records of 1 second duration

Monitoring Functions
- Primary/Secondary Current Phases and Earth
- Direction
- Primary/Secondary Line and Phase Voltages
- Apparent Power and Power Factor
- Real and Reactive Power
- W Hr & VAr Hr Forward and Reverse
- Historical Demand Record
- Positive Phase Sequence (PPS) Voltage & Current
- Negative Phase Sequence (NPS) Voltage & Current
- Zero Phase Sequence (ZPS) Voltage

Hardware
- 1 CT 3 VT 3 Binary Inputs 5 Binary Outputs
- 4 CT 3 VT 3 Binary Inputs 5 Binary Outputs
- 4 CT 3 VT 6 Binary Inputs 8 Binary Outputs
- Auxiliary Supply 80 to 250V DC or 24 to 60V DC

8
Relay Selection Guide - Version 1.0

Numerical Feeder Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

50, 50N, 51, The 7SJ61 relay can be used for line protection of high and medium 7SJ61
51N, 46, 49, voltage networks.When protecting motors, the 7SJ61 is suitable for
asynchronous machines of all sizes. The relay performs all functions
74 TC, 50BF, 37,
of backup protection supplementary to transformer differential
86 protection.
Features
Optional
- DT/IDMT: l>,I>>, l>>>; IE>, lE>>, lE>>> / lp>, lEp>; IEE>, IEE>>,
79M, 50Ns, IEEp>
51Ns, 64, 67Ns, - Motor protection
14/ 48, 64H/87N, o Overload protection
66/86, 51M o Unbalance load protection
o Start-up monitoring
- Reverse Interlocking
- Trip circuit supervision
- Cold load pickup (e.g. for energising transformers)
- Disk emulation
- Commands for control of a circuit-breaker and of isolators
- Control via keyboard, binary inputs,
- DIGSI 4 or SCADA system
- User-defined logic with CFC (e.g. interlocking)

User Interface
- Control via keyboard
- 8 LEDs (6 are independently programmable)
- User Friendly and keys for front operation

Communication Interface
- System interface
o IEC 60870-5-103, IEC 61850
o PROFIBUS-FMS/-DP
o DNP 3.0/MODBUS RTU
- Service interface for DIGSI 4 (modem)
- Front interface for DIGSI 4
- Time synchronization via IRIG B/DCF77

Data Storage
- Fault event logging with time stamp (buffered)
- 8 oscillographic fault records

Monitoring Functions
- Operational measured values I
- Circuit-breaker wear monitoring
- Slave pointer
- Time metering of operating hours
- Motor statistics

Hardware
- 4 current transformers
- 3/8/11 binary inputs
- 4/8/6 output relays
- CT Inputs 1A or 5A (selectable via Jumper)
- Auxiliary voltage: 60 - 125V DC, 110 - 250 V A.C. 110-220V DC,
24/48 V DC, 230 V AC
- 1 Live Status contact

9
Relay Selection Guide - Version 1.0

Numerical Feeder Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

37, 46BC, The 7SR210 is a new generation of non-directional and directional 7SR21
46NPS, 49, 50, overcurrent protection relays, built on years of numeric relay
protection experience with the Argus family of products. Housed in
50G/N, 50BF, 51,
4U high, size E6 or E8 cases, these relays provide protection, control,
51G/N /SEF monitoring, instrumentation and metering with integrated input and
64H, 74TC, output logic, data logging & fault reports.
81HBL2 Features
- 8 Settings Groups
Optional - Password Protection – 2 levels
79M - User Programmable Logic
- Self Monitoring
- Reverse Interlocking
- Trip circuit supervision
User Interface
- Control via keyboard
- 8 or 16 Programmable Tri-colour LEDs (Option)
- Menu navigation and User Friendly keys for front operation
- 6 Programmable Function Keys each with Tri-colour LED (Option)
Communication Interface
- 2 Rear ST fibre optic ports (2 x Tx/Rx) + IRIG-B port
- 1 Rear RS485 + IRIG-B port
- 1 Rear RS232 + IRIG-B port
- 2 Rear RS485 Port + IRIG-B
- 2 Rear RS232 Port +IRIG-B
- IEC60870-5-103, Modbus RTU and optional DNP 3.0 protocols –
User selectable with programmable data points
Data Storage
- Fault event logging with time stamp (buffered)
- 10 oscillographic fault records
- 5000 events time tagged to 1 ms resolution
- Waveform storage is selectable from either 10 records of 1
second, 5 records of 2 seconds, 2 records of 5 seconds or 1 record
of 10 seconds duration.
Monitoring Functions
- Primary current phases and earth
- Secondary current phases and earth
- Positive Phase Sequence (PPS) Current
- Negative Phase Sequence (NPS) Current
- Zero Phase Sequence (ZPS) Current
- Binary Input/Output status
- Trip circuit healthy/failure
- Time and date
- Starters
- Fault records
- Event records
- Frequency
- Waveform records
- Circuit breaker trip counters
- I2t summation for contact wear
- Demand metering
Hardware
- 4 CT, 9 Binary Inputs / 8 Binary Outputs
- 4 CT, 19 Binary Inputs / 16 Binary Outputs
- 4 CT, 19 Binary Inputs / 16 Binary Outputs
- 1A or 5A (selectable )
- Auxiliary voltage: 30 to 220V DC

10
Relay Selection Guide - Version 1.0

Numerical Feeder Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

37, 46BC, The 7SR220 is a new generation of non-directional and directional 7SR22
46NPS, 49, 50, overcurrent protection relays, built on years of numeric relay
protection experience with the Argus family of products. Housed in
50G/N, 50BF, 51,
4U high, size E6 or E8 cases, these relays provide protection, control,
51G/N /SEF monitoring, instrumentation and metering with integrated input and
60CTS, 64H, output logic, data logging & fault reports
74TC, 81HBL2, Features
27, 59, 37G, - 8 Settings Groups
37SEF, 47, 51V, - Password Protection – 2 levels
- User Programmable Logic
59N, 60VTS,
- Self Monitoring
67/50, 67/50G, - Reverse Interlocking
67/50N, 67/51, - Trip circuit supervision
67/51G, 67/51N, - Cold Load Pickup
81U/O User Interface
- Control via keyboard
- 8 or 16 Programmable Tri-colour LEDs (Option)
Optional
- Menu navigation and User Friendly keys for front operation
79M - 6 Programmable Function Keys each with Tri-colour LED (Option)
Communication Interface
- 2 Rear ST fibre optic ports (2 x Tx/Rx) + IRIG-B port
- 1 Rear RS485 + IRIG-B port
- 1 Rear RS232 + IRIG-B port
- 2 Rear RS485 Port + IRIG-B
- 2 Rear RS232 Port +IRIG-B
- IEC60870-5-103, Modbus RTU and optional DNP 3.0 protocols –
User selectable with programmable data points
Data Storage
- Fault event logging with time stamp (buffered)
- 10 oscillographic fault records
- 5000 events time tagged to 1 ms resolution
- Waveform storage is selectable from either 10 records of 1
second, 5 records of 2 seconds, 2 records of 5 seconds or 1 record
of 10 seconds duration.
Monitoring Functions
- Primary current phases and earth
- Secondary current phases and earth
- Positive Phase Sequence (PPS) Current
- Negative Phase Sequence (NPS) Current
- Zero Phase Sequence (ZPS) Current
- Binary Input/Output status
- Trip circuit healthy/failure
- Time and date
- Starters
- Fault records
- Event records
- Frequency
- Waveform records
- Circuit breaker trip counters
- I2t summation for contact wear
- Demand metering
Hardware
- 5 CT, 4 VT, 3 Binary Inputs / 6 Binary Outputs
- 5 CT, 4 VT, 13 Binary Inputs / 14 Binary Outputs
- 5 CT, 4 VT, 13 Binary Inputs / 14 Binary Outputs
- 1A or 5A (selectable )
- 63.5/ 110V, 50/60 Hz
- Auxiliary voltage: 30 to 220V DC

11
Relay Selection Guide - Version 1.0

Numerical Feeder Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

50, 50N, 51, The 7SJ80 relays with removable current and voltage terminals, 7SJ80
51N, 46, 49, can be used for line/feeder protection of high and medium voltage
networks.The relays have all the required functions to be applied as a
50Ns, 51Ns, 74
backup relay to a transformer differential relay.
TC, 50BF, 37, 86,
Features
64R/87N
- DT/IDMT: I>, l>>, l>>>; IE>, lE>>, lE>>> / lp>, lEp>; lEE>, lEE>>,
lEEp>>; ldir>, ldir>>, lpdir; lEdir>, lEdir>>, lEpdir>
Optional - Motor protection
79M, 67Ns, o Overload protection
27/59, 59N, o Unbalance load protection
81U/O, 81R, 67, o Start-up monitoring
67N, 67Ns, 25, - Reverse Interlocking
21FL, 47 - Trip circuit supervision
- Fault Locator
- Sync Check
- Cold load pickup (e.g. for energising transformers)
- Displacement voltage
- Control via keyboard, binary inputs,
- DIGSI 4 or SCADA system
- User-defined logic with CFC (e.g. interlocking)
- Pluggable current and voltage terminals

User Interface
- Control via keyboard
- 10 LEDs (8 are independently programmable)
- User Friendly and keys for front operation
- User-defined PLC logic with CFC

Communication Interface
- System interface
o IEC 60870-5-103, IEC 61850
o PROFIBUS-FMS/-DP
o DNP 3.0/MODBUS RTU
- Ethernet interface for DIGSI 4
- USB front interface for DIGSI 4

Data Storage
- Fault event logging with time stamp (buffered)
- 8 oscillographic fault records

Monitoring Functions
- Operational measured values V, I, f
- Energy metering values Wp, Wq
- Circuit-breaker wear monitoring
- Slave pointer
- Fuse failure monitor
- Motor statistics

Hardware
- 4 current transformers
- 0 / 3 voltage transformers
- 3 / 7 binary inputs
- 5 / 8 output relays
- CT Inputs 1A or 5A (selectable)
- Auxiliary voltage: 60 - 125V DC, 110 - 250 V A.C. 110-220V DC,
24/48 V DC, 230 V AC
- 1 Live Status contact

12
Relay Selection Guide - Version 1.0

Numerical Feeder Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

50, 50N, 51, The 7SJ62 relays can be used for line protection of high and 7SJ62
51N, 46, 49, medium voltage networks with earthed (grounded), low-resistance
earthed, isolated or compensated neutral point. With regard to
74 TC, 50BF, 37,
motor protection, the 7SJ62 is suitable for asynchronous machines
51V, 86, of all sizes. The relay performs all functions of backup protection
59N, 47 supplementary to transformer differential protection.
Features
Optional - DT/IDMT: l>, I>>, l>>>; lE>, IE>>, lE>>> / lp>, lEp>; lEE>, IEE>>,
79M, 50Ns, lEEp> / ldir>, ldir>>, Ipdir>; IEdir>, lEdir>>, lEpdir>
51Ns, 64, 67Ns, - Motor protection
o Overload protection
27/59, 81U/O,
o Unbalance load protection
81R, 67, 67N, o Start-up monitoring
67Ns, 87N/64R, - Reverse Interlocking
14/ 48, 64H/87N, - Trip circuit supervision
66/86, 51M, 25, - Fault Locator
- Sync Check
21FL
- Cold load pickup (e.g. for energising transformers)
- Displacement voltage
- Disk emulation
- Commands for control of a circuit-breaker and of isolators
- Control via keyboard, binary inputs,
- DIGSI 4 or SCADA system
- User-defined logic with CFC (e.g. interlocking)
User Interface
- Control via keyboard
- 8 LEDs (6 are independently programmable)
- User Friendly and keys for front operation
- 4 Freely assignable Function keys
Communication Interface
- System interface
o IEC 60870-5-103, IEC 61850
o PROFIBUS-FMS/-DP
o DNP 3.0/MODBUS RTU
- Service interface for DIGSI 4 (modem)
- Front interface for DIGSI 4
- Time synchronization via IRIG B/DCF77
Data Storage
- Fault event logging with time stamp (buffered)
- 8 oscillographic fault records
Monitoring Functions
- Operational measured values V, I, f
- Energy metering values Wp, Wq
- Circuit-breaker wear monitoring
- Slave pointer
- Fuse failure monitor
- Motor statistics
Hardware
- 4 current transformers
- 3 / 4 voltage transformers
- 8 /11 binary inputs
- 8 / 6 output relays
- CT Inputs 1A or 5A (selectable via Jumper)
- Auxiliary voltage: 60 - 125V DC, 110 - 250 V A.C. 110-220V DC,
24/48 V DC, 230 V AC
- 1 Live Status Contact

13
Relay Selection Guide - Version 1.0

Numerical Feeder Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

50, 50N, 51, The 7SJ63 can be used as a protective control and monitoring 7SJ63
51N, 46, 49, 74 relay for distribution feeders and transmission lines of any voltage
TC, 50BF, 37, in networks that are earthed (grounded), low-resistance earthed,
51V, 86, 59N, 47 unearthed, or of a compensated neutral point structure. The relay is
suited for networks that are radial or looped, and for lines with single
Optional or multi-terminal feeds. The 7SJ63 is equipped with motor protection
applicable for asynchronous machines of all sizes. Motor protection
79M, 50Ns, comprises undercurrent monitoring, starting time supervision, restart
51Ns, 64, 67Ns, inhibit, locked rotor
27/59, 81U/O, Features
81R, 67, 67N, - DT/IDMT: l>, I>>; lE>, IE>>, / lp>, lEp>; lEE>, IEE>>, lEEp> ; ldir>,
67Ns, 87N/64R, ldir>>, Ipdir>; IEdir>, lEdir>>, lEpdir>
14/ 48, 64H/87N, - Motor protection
66/86, 51M, 25, o Overload protection
21FL o Unbalance load protection
o Start-up monitoring
- Reverse Interlocking
- Trip circuit supervision
- Fault Locator
- Sync Check
- Cold load pickup (e.g. for energising transformers)
- Displacement voltage
- Commands for control of a circuit-breaker and of isolators
- Control via keyboard, binary inputs,
- DIGSI 4 or SCADA system
- User-defined logic with CFC (e.g. interlocking)
User Interface
- Control via keyboard
- 16 LEDs (14 are independently programmable)
- User Friendly and keys for front operation
- 4 Freely assignable Function keys
- Flexible number of switching devices
- Position of switching elements is shown on the graphic display
- Local/remote switching via key operated switch
Communication Interface
- System interface
o IEC 60870-5-103, IEC 61850
o PROFIBUS-FMS/-DP
o DNP 3.0/MODBUS RTU
- Service interface for DIGSI 4 (modem)
- Front interface for DIGSI 4
- Time synchronization via IRIG B/DCF77
Data Storage
- Fault event logging with time stamp (buffered)
- 8 oscillographic fault records
Monitoring Functions
- Operational measured values V, I, f
- Energy metering values Wp, Wq
- Circuit-breaker wear monitoring
- Slave pointer
- Fuse failure monitor
- Motor statistics
Hardware
- 4 current transformers
- 3 / 4 voltage transformers
- 11/ 24/ 20/ 37/ 33 Binary Inputs
- 2 measuring Transducer Inputs (Optional)
- 8 / 11 output relays
- CT Inputs 1A or 5A (selectable via Jumper)
- Auxiliary voltage: 60 - 125V DC, 110 - 250 V A.C. 110-220V DC,
24/48 V DC, 230 V AC
- 1 Live Status Contact
14
Relay Selection Guide - Version 1.0

Numerical Motor Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

50, 50N, 51, The 7SJ600 is a numerical overcurrent relay which, in addition to its 7SJ600
51N, 46, 49, 51C primary use in radial distribution networks and motor protection, can
also be employed as backup for feeder, transformer and generator
14/ 48, 74 TC,
differential protection
Features
79M (Optional)
- DT/IDMT: l>, I>>, l>>>; lE>, IE>> / Ip>, IEp>
- Motor protection
o Overload protection
o Unbalance load protection
o Start-up monitoring
- Reverse Interlocking
- Trip circuit supervision
- Cold load pickup (e.g. for energising transformers)

User Interface
- Control via keyboard
- 6 LEDs (4 are independently programmable)
- User Friendly and keys for front operation

Communication Interface
- Serial interface with IEC-protocol / DIGSI V3 Or DIGSI 4 (≥ 4.3)
- Via RS232 – RS485 converter
- Via modem
- IEC 60870-5-103 protocol, 2 kV-isolated
- RS485 interface

Data Storage
- Fault event logging with time stamp (buffered)
- 8 oscillographic fault records

Monitoring Functions
- Primary/Secondary Current Phases and Earth

Hardware
- 2 Alarm relays (independently programmable)
- 3 Binary inputs (independently programmable)
- 2 Trip contacts with 2 making contacts each (independently
programmable)
- OPEN/CLOSE test power circuit breaker
- 3 CT Inputs : 1A or 5A (selectable via Jumper)
- Auxiliary voltage: D.C. 60 - 125V, 110 - 250 V / A.C. 115 V (via
Jumper), D.C. 24/48 V, A.C. 230 V
- 1 Live Status contact

15
Relay Selection Guide - Version 1.0

Numerical Motor Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

50, 50N, 51, The 7SJ602 is a numerical overcurrent relay which, in addition to its 7SJ602
51N, 46, 49, 51C primary use in radial distribution networks and motor protection, can
also be employed as backup for feeder, transformer and generator
74 TC, 50BF
differential protection
Features
Optional
79M, 50Ns, - DT/IDMT: l>, I>>, l>>>; lE>, IE>>, / lp>, lEp>; lEE>, IEE>>, IEp>
51Ns, 64, 67Ns, - Motor protection
14/ 48, 37, 66/86 o Overload protection
o Unbalance load protection
o Start-up monitoring
- Reverse Interlocking
- Trip circuit supervision
- Cold load pickup (e.g. for energising transformers)
- Displacement voltage
- Disk emulation

User Interface
- Control via keyboard
- 6 LEDs (4 are independently programmable)
- User Friendly and keys for front operation

Communication Interface
- Serial interface with IEC-protocol / DIGSI V3 Or DIGSI 4 (≥ 4.3)
- Via RS232 – RS485 converter
- Via modem
- IEC 60870-5-103 protocol, 2 kV-isolated
- RS485 interface

Data Storage
- Fault event logging with time stamp (buffered)
- 8 oscillographic fault records

Monitoring Functions
- Operational measured values I, V
- Power measurement P, Q, S, Wp, Wq
- Slave pointer
- Mean values

Hardware
- 4 current transformers or
- 3 current + 1 voltage transformers
- 3 binary inputs
- 4 output relays
- CT Inputs 1A or 5A (selectable via Jumper)
- Auxiliary voltage: D.C. 60 - 125V, 110 - 250 V / A.C. 115 V (via
Jumper), D.C. 24/48 V, A.C. 230 V
- 1 Live Status contact

16
Relay Selection Guide - Version 1.0

Numerical Motor Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

50, 50N, 51, The 7SG17 Rho 3 is a multi-function numerical Motor Protection relay 7SG17
51N, 46NPS, 49, suitable for all types of a.c. induction motors up to the highest ratings
available.The relay can be set to accurately mimic both the heating and
74 TC, 50BF,
cooling characteristics of the protected motor and consequently ensure
60CTS, 50Ns, that the thermal withstand of the machine is not exceeded, The 7SG17
37, 86, 14/48 Rho 3 is a multi-function numerical Motor Protection relay suitable for all
types of a.c. induction motors up to the highest ratings available
Features
- Advanced motor protection - for medium voltage motors
- Easily programmable settings and user interface
- CT supervision
- 4 Settings Groups
- Self Monitoring
- Trip circuit supervision
- Hot/ Cold Ratio Monitoring
- Motor Statistics
User Interface
- 16 character x 2 line backlit LCD
- Menu navigation keys
- LEDs for TRIP, MOTOR STARTING, MOTOR RUNNING, STARTER and
PROTECTION HEALTHY status.
- Menu navigation and User Friendly keys for front operation
Communication Interface
- IEC60870-5-103, Modbus RTU and optional DNP 3.0 protocols –
User selectable with programmable data points
- FO communications port is provided on the rear of the relay
Data Storage
- Fault event logging with time stamp (buffered)
- 5 oscillographic fault records
- 500 events time tagged to 1 ms resolution
- Waveform storage is selectable from either 10 records of 1
second, 5 records of 2 seconds, 2 records of 5 seconds or 1 record
of 10 seconds duration.
Monitoring Functions
- Primary/secondary currents
- Motor full load current
- PPS & NPS currents
- Thermal equivalent current
- Phase difference current
- Motor status (Stopped, running)
- Time to trip
- Time to start
- Thermal capacity used
- Total starts
- Last start time
- Last start current
- Motor run time
- Total run time
- Maximum demand/time
- Output relay status
- Status inputs
- Trip circuit healthy/failure
- Trip counters
- I2 summation
- Number of waveform and event records stored
- Time and Date
Hardware
- 4 CT, 1 Binary Inputs / 7 Binary Outputs
- 4 CT, 9 Binary Inputs / 7 Binary Outputs
- 1A or 5A (selectable )
- Optional 8 thermistor or resistance temperature detector (RTD) inputs
- Auxiliary voltage: 24/30/48 V DC, 110/220 V DC
17
Relay Selection Guide - Version 1.0

Numerical Motor Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

50, 50N, 51, The 7SK80 is a multifunctional motor protection relay. It is designed 7SK80
51N, 46NPS, for asynchronous induction-type motors of all sizes. The relays have
49, 50Ns, 51Ns, all the functionality to be applied as a backup relay to a transformer
74TC, 50BF, 37, differential relay.
86, 14/48, 66/86,
Features
51M
- DT/IDMT: I>, l>>; lE>, IE>>; Ip>, IEp>; IEE>, lEE>>, lEEp;
Optional ldir>, ldir>>, lpdir>; lEdir>, lEdir>>, lEpdir>
67Ns, 27/59, - Motor protection
59N, 67, 67N, o Overload protection
81U/O, 81R, 47, o Unbalance load protection
32 o Start-up monitoring
- Reverse Interlocking
- Trip circuit supervision
- Inrush Restraint
- Cold load pickup (e.g. for energising transformers)
- Displacement voltage
- Control via keyboard, binary inputs,
- DIGSI 4 or SCADA system
- User-defined logic with CFC (e.g. interlocking)
- Pluggable current and voltage terminals
User Interface
- Control via keyboard
- 10 LEDs (8 are independently programmable)
- User Friendly and keys for front operation
- User-defined PLC logic with CFC
Communication Interface
- System interface
o IEC 60870-5-103, IEC 61850
o PROFIBUS-FMS/-DP
o DNP 3.0/MODBUS RTU
- Ethernet interface for DIGSI 4
- USB front interface for DIGSI 4
Data Storage
- Fault event logging with time stamp (buffered)
- 8 oscillographic fault records
Monitoring Functions
- Operational measured values V, I, f
- Energy metering values Wp, Wq
- Circuit-breaker wear monitoring
- Slave pointer
- Fuse failure monitor
- Motor statistics
Hardware
- 4 current transformers
- 0 / 3 voltage transformers
- 3 / 7 binary inputs
- 5 / 8 output relays
- 5 RTD Inputs (Optional)
- CT Inputs 1A or 5A (selectable)
- Auxiliary voltage: 60 - 125V DC, 110 - 250 V A.C. 110-220V DC,
24/48 V DC, 230 V AC
- 1 Live Status contact

18
Relay Selection Guide - Version 1.0

Numerical Transformer Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

87T The 7SR242 is a new generation of Inregrated Transformer Protection 7SR242


(2Windings), Relay for 2 winding transformer differential protection. The relays
utilise years of numeric relay protection experience with the ‘Duobias’
87HS, 50BF,
family of products
51, 64H, 74TC,
Features
81HBL2, 81HBL5
- 8 Settings Groups
- Password Protection – 2 levels
Optional - User Programmable Logic
37,46NPS, 49, - Self Monitoring
50, 50G/N/SEF, - Inrush Restraint or Block
51G/N/SEF, 24,
User Interface
27/59, 59N, - Control via keyboard
81 U/O - 16 or 24 user programmable tri-colour LED’s (Option)
- Menu navigation and User Friendly keys for front operation
- 6 Programmable Function Keys each with Tri-colour LED (Option)
Communication Interface
- 2 Rear ST fibre optic ports (2 x Tx/Rx) + IRIG-B port
- 1 Rear RS485 + IRIG-B port
- 1 Rear RS232 + IRIG-B port
- 2 Rear RS485 Port + IRIG-B
- 2 Rear RS232 Port +IRIG-B
- IEC60870-5-103, Modbus RTU and optional DNP 3.0 protocols –
User selectable with programmable data points
Data Storage
- Fault event logging with time stamp (buffered)
- 10 oscillographic fault records
- 5000 events time tagged to 1 ms resolution
- Waveform storage is selectable from either 10 records of 1
second, 5 records of 2 seconds, 2 records of 5 seconds or 1 record
of 10 seconds duration.
Monitoring Functions
- Secondary current phases and earth
- Relay Operate and restraint currents
- Positive Phase Sequence (PPS) Current
- Negative Phase Sequence (NPS) Current
- Zero Phase Sequence (ZPS) Current
- Thermal status
- Primary Single phase voltage*
- Secondary single phase voltage*
- Data logging and Demand Metering
- Frequency & fluxing*
- Binary Input/binary output and virtual I/O status
- Trip circuit healthy/failure
- Time and date
- Fault records
- Event records
- Waveform records
- Circuit breaker trip counters
- I2t summation for contact wear
- * Optional voltage measurements from single phase VT input
Hardware
- 8 CT, 1 VT, 9 Binary Inputs / 6 Binary Outputs
- 8 CT, 1 VT, 19 Binary Inputs / 14 Binary Outputs
- 1A or 5A (selectable )
- 63.5/ 110V, 50/60 Hz
- Auxiliary voltage: 30 to 220V DC
19
Relay Selection Guide - Version 1.0

Numerical Transformer Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

87T The 7UT6 differential protection relays are used for fast and selective 7UT612
(2Windings), fault clearing of short-circuits in transformers of all voltage levels
and also in rotating electric machines like motors and generators, for
50, 51, 86, 49 ,
short lines and busbars. The protection relay can be parameterized
81HBL2 for use with three-phase and single-phase transformers.
Features
Optional
- Two Winding Differential Protection
87N/ 64H, 46,
- Trip circuit supervision
50BF, 74TC
- Sensitive measuring for low-fault currents
- Fast tripping for high-fault currents
- Restraint against inrush of transformer
- Control via keyboard, binary inputs,
- DIGSI 4 or SCADA system
- User-defined logic with CFC (e.g. interlocking)
- Selectable Binary Input Thresholds

User Interface
- Control via keyboard
- 8 LEDs (6 are independently programmable)
- User Friendly and keys for front operation
- 4 Freely assignable Function keys
- Flexible number of switching devices

Communication Interface
- System interface
o IEC 60870-5-103, IEC 61850
o PROFIBUS-FMS/-DP
o DNP 3.0/MODBUS RTU
- Service interface for DIGSI 4 (modem)
- Front interface for DIGSI 4
- Time synchronization via IRIG B/DCF77

Data Storage
- Fault event logging with time stamp (buffered)
- 8 oscillographic fault records

Monitoring Functions
- Operational measured values I
- Circuit-breaker wear monitoring
- Slave pointer

Hardware
- 8 current transformers
- 3 Binary Inputs
- 6 RTD Input Interface via. Thermo box (optional)
- 4 output relays
- CT Inputs 1A or 5A (selectable via Jumper)
- Auxiliary voltage: 60 - 125V DC, 110 - 250 V A.C. 110-220V DC,
24/48 V DC, 230 V AC
- 1 Live Status Contact

20
Relay Selection Guide - Version 1.0

Numerical Transformer Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

87BD (3 The 7SG14 Duobias-M is a transformer protection relay with biased 7SG14
Windings), 87HS differential transformer protection. It is capable of providing all
necessary protection and alarm functions for protecting a 2 or
Optional
3 winding transformer. The main protection function is current
50, 51, 50N, differential with load bias and second harmonic restraining
51N, 50G, 51G, characteristic. This is supplemented with a number of additional
86, 49 , 81HBL2, functions to provide a comprehensive transformer protection
management package.
87N/ 64H, 46,
50BF, 74TC, 27, Features
59, 81U/O, 32, - 4 Settings Groups
24 - User Programmable Logic
- Self Monitoring
- Inrush Restraint or Block
- Vector group compensation and ratio correction

User Interface
- Control via keyboard
- 16 or 32 user programmable tri-colour LED’s (Option)
- Menu navigation and User Friendly keys for front operation
- 20 character x 2 line backlit LCD
- 1 fixed LED

Communication Interface
- Communication access to relay functionality is via a front RS232
port for local PC connection.
- Two rear ST fibre optic ports (2 x Tx/Rx) and an IRIG-B are also
provided
- IEC60870-5-103, Modbus RTU protocols – User selectable with
programmable data points

Data Storage
- Fault event logging with time stamp (buffered)
- 10 oscillographic fault records
- 500 events time tagged to 1 ms resolution
- Waveform storage is selectable from either 5 records of 1 second,
1 sec of 5 records.

Monitoring Functions
- Line currents for each winding
- Relay currents for each winding (after ratio and vector group
- compensation)
- Operate and restrain currents
- Binary inputs
- Output contacts

Hardware
- 17 CT, 0/1 VT
- 3 / 11/ 19/ 27 Binary Inputs
- 5 / 13, 21/ 29 Binary Outputs
- 1A or 5A (selectable )
- 63.5/ 110V, 50/60 Hz
- Auxiliary voltage: 30 to 220V DC

21
Relay Selection Guide - Version 1.0

Numerical Transformer Protection


PROTECTION DESCRIPTION TYPE
ANSI CODES

87T (3 The 7UT6 differential protection relays are used for fast and selective 7UT613
Windings), 50, fault clearing of short-circuits in transformers of all voltage levels
and also in rotating electric machines like motors and generators, for
51, 50N, 51N,
short lines and busbars. The protection relay can be parameterized
50G, 51G, 86, 49 for use with three-phase and single-phase transformers.
, 81HBL2
Features
Optional - Three Winding Differential Protection
87N/ 64H, 46, - Trip circuit supervision
50BF, 74TC, 27, - Sensitive measuring for low-fault currents
59, 81U/O, 32, - Fast tripping for high-fault currents
24 - Restraint against inrush of transformer
- Control via keyboard, binary inputs,
- DIGSI 4 or SCADA system
- User-defined logic with CFC (e.g. interlocking)
- Selectable Binary Input Thresholds

User Interface
- Control via keyboard
- 16 LEDs (14 are independently programmable)
- User Friendly and keys for front operation
- 4 Freely assignable Function keys
- Flexible number of switching devices

Communication Interface
- - System interface
o IEC 60870-5-103, IEC 61850
o PROFIBUS-FMS/-DP
o DNP 3.0/MODBUS RTU
- Service interface for DIGSI 4 (modem)
- Front interface for DIGSI 4
- Time synchronization via IRIG B/DCF77

Data Storage
- Fault event logging with time stamp (buffered)
- 8 oscillographic fault records

Monitoring Functions
- Operational measured values I
- Metering Values, Energy Metering
- Circuit-breaker wear monitoring
- Slave pointer

Hardware
- 12 current transformers
- 5 Binary Inputs
- 6 RTD Input Interface via. Thermo box (optional)
- 8 output relays
- CT Inputs 1A or 5A (selectable via Jumper)
- Auxiliary voltage: 60 - 125V DC, 110 - 250 V A.C. 110-220V DC,
24/48 V DC, 230 V AC
- 1 Live Status Contact

22
Relay Selection Guide - Version 1.0

Notes :

23
Regional Sales Offices

NORTH - Gurgaon EAST - Kolkata


Siemens Ltd. Siemens Ltd.
Energy sector Energy sector
3rd Floor, Plot 6A, Sector 18, 43, Shantipalli
Maruti Industrial Area Eastern Metropolitan Bypass
Gurgaon, Haryana - 122015 R B connector, Kolkatta
India West Bengal - 700042
Contact Person: Mr. I.K. Rai India
Tel. (Dir.): +91 124 4697376 Contact Person : Mr. Ashoke Roy
Mobile: +91 9818018701 Tel. (Dir.): +91 33 24449000
E-mail: [email protected] Mobile: +91 9830006653
E-mail: [email protected]
WEST - Mumbai
Siemens Ltd. SOUTH - Chennai
Energy sector Siemens Ltd.
3rd Floor, R&D Tech Centre, Energy sector
Thane Belapur Road, Thane - 400601 144, Mahatma Gandhi Road
India Chennai (Madras)
Contact Person: Mr. Sachin Jaguste / Mr. Neenad Wilankar Tamil Nadu- 600034
Tel. (Dir.): +91 22 27645221 India
Mobile: +91 9819155056 Contact Person: Mr. Muralidharan Krishnan
E-mail: [email protected] Tel. (Dir.): +91 44 28334608
Mobile: +91 9867665588 Mobile: +91 9962592826
E-mail: [email protected] E-mail: [email protected]

WEST - Baroda
Siemens Ltd.
Energy sector
3rd Floor, Ohm Business Park
Opp. Balaji Hospital, Ellora Park
Subhanpura, Vadodara - 23
Gujarat, India
Contact Person: Mr. Mandar Pagedar
Tel. (Dir.): +91 265 6692131
Mobile: +91 9925004384
E-mail: [email protected]

For any Technical Documentation, pls visit the below URL


http://www.energy.siemens.com/hq/en/automation/power-transmission-
distribution/protection/
For any general queries and technical support, pls write to us at
[email protected]

Siemens Ltd. ENE-03-152-002 Contact Person: Mr. Kuldeep Tickoo / Mr. Aditya Dubey
Energy Sector E-mail: [email protected],
Plot No. 6A, Sector 18, Maruti Industrial Area [email protected]
Huda, Gurgaon - 122 015, India.
Tel.: +91 124 2846000, 2846248, 4697362
Fax: +91 124 2846261
Customer Care Toll free no. 1800 419 7477
www.siemens.co.in Email: [email protected] Product upgradation is a continuous process. Hence, data in
this brochure is subject to change without prior notice. For the
latest information, please get in touch with our Sales Offices.

You might also like