Introduction
A DC generator, whose schematic equivalent circuit is shown in figure 1, is an electrical machine that
converts the mechanical energy of a prime mover (e.g. DC motor, AC induction motor or a turbine)
into direct electrical energy. The generator shown in figure 1 is self-exciting. It uses the voltage Ea
generated by the machine to establish the field current If, which in turn gives rise to the magnetic-
field flux Φ. When the armature winding rotates in this magnetic field to cut the flux, the voltage Ea
is induced in the armature. This voltage is commonly referred to as the armature electromotive force
or EMF. The induced EMF is proportional to the rate of cutting the flux and is given by emf formula.
where,
Φ = flux in webers
n = armature speed in rpm
Z = total number of armature conductors
p = number of poles
a = number of parallel paths
In the case of a compound generator, the series and shunt fields may be connected so as to aid each
other, i.e., the fluxes set up by each will add up.
An increase in the total flux will generate a greater EMF. Such a connection is known as cumulative.
If, however, the shunt and series windings are so connected that the flux set up by one opposes the
other, then the induced EMF will be smaller. This type of connection is called differential.
It is that value of the field resistance at which the D.C. Shunt Generator will fail to excite. It is that
speed for which the given shunt field resistance becomes the critical field resistance. Critical field
resistance is obtained by plotting the OCC as in fig.2 and determining the slope of the tangent to the
linear position of the curve from the origin. While drawing the tangent, the initial position of the
O.C.C is neglected.
Due to residual magnetism in the poles, a small amount of EMF is generated even when If = 0. Hence,
the curve starts a little way up. The slight curvature at the lower end is due to magnetic inertia. It has
seen that the first part of the curve is practically straight. Hence the flux and consequently generated
EMF is directly proportional to the exciting current. However at the higher flux densities where it is
small iron path reluctance becomes appreciable and straight. Field windings are connected parallel to
the armature, so it is called DC Shunt Generator. Due to residual magnetism some initial emf and
hence some current will be generated. This current while passing into the field coils will strengthen
the magnetism of poles. This will increase pole flux which will further increase the generated emf.
Increased emf and flux proceeds till equilibrium reached. This reinforcement of emf and flux
proceeds till equilibrium reached at some point in the graph between If and Eg*