Maytas Infra Limited The following should be read : 1) ACSR Moose Conductor is used for all connections. 2) Twin Moose Buses - 3 Nos(220KV - 1 No; 132KV- 2 Nos) 3) Twin Bus Spacing is with 400 mm;All sapcer calmps must be of 400mm spacing. S.No 1 2 3 4 5 Description of Material 5-Bolted type- Tension Hardware for Twin Moose Conductor with 400mm Spacing for 220KV/132KV BUS Spacer Clamps suitable for Moose Conductor with 400mm Spacing for 220KV/132KV Spacer T-Clamps suitable for Moose Conductor with 400mm Spacing for 220KV/132KV Supsension Clamps suitable for Twin Moose Conductor for single 70KN Disc String 5-Bolted Tension Hardware for Single Moose conductor for 132KV BUS - I & BUS -II Required Quanitity 24 60 27 9 12 7 2 36 76 30 6 18 45
6 Post Type Insulator support clamps for Single Moose Conductor 7 Post Type Insulator support clamps for Twin Moose Conductor 8 3-Bolted Earthwire Tension Clamp for 7/3.15mm wire( Total 26 Connections , 18 x 2 = 36 Nos)
9 T-Clamps Suitable for ACSR Moose 3-Ways 10 PG Clamps Suitable for ACSR Moose in both grooves 11 Supsension Clamp for Single ACSR Moose Conductor 12 Pad Clamps Suitable for Twin Moose( Breaker) 13 Supply of U-Bolts 16mm
2 Spacer Clamps suitable for Moose Conductor with 400mm Spacing for 220KV/132KV Buses Phases Nos/Bus Total 2 3 6 36 For 220KV BUS-I& BUS-II 2 3 4 24 For 132KV BUS-I&BUSII 60 3 Spacer T-Clamps suitable for Moose Conductor with 400mm Spacing for 220KV/132KV For 220KV BUS Isolators For 132KV PTR BUS Isolators Nos 7 2 Phases 3 3 Sides 1 1 Total 21 6 27 Total 3 6 9
4 Supsension Clamps suitable for Twin Moose Conductor Nos Phases 1 3 For 220KV BUS-I& BUS-II Jumpers 2 3 For 132KV BUS-I&BUSII Jumpers
Sides 1 1
5 5-Bolted Tension Hardware for Single Moose conductor for 220KV/132KV For 132KV Auxillary Bus Buses 2 Phases 3 Sides 2 12
6 Post Type Insulator support clamps for Single Moose Conductor For 220KV Bus Isolators Nos 7 Phases 1 Sides 1 7
7 Post Type Insulator support clamps for Twin Moose Conductor For 132KV Bus Jumpers Nos 2 Phases 1 Sides 1 2
8 3-Bolted Earthwire Tension Clamp - 26 Nos; 18 x 2 Sides = 36 Nos 9 T-Clamps Suitable for ACSR Moose 3-Ways Bays For 220KV LA's For 220KV CVT's For Wave Traps 220KV From Wave Trap to Isolator For 220KV BUS-I to BUS-II Jumpers From 132KV PTR Aux Bus to 132KV Bushings From 132KV PTR Aux Bus to 132KV LA's For 132KV BUS-I to BUS-II Jumpers For Bye Pass Jumpers 132KV PTR BUS 2 2 2 2 2 2 2 2 2 Phases 3 3 1 1 3 3 3 3 3 Sides 1 1 1 1 2 1 1 4 2
6 6 2 2 12 6 6 24 12 76
10 PG Clamps Suitable for ACSR Moose in both grooves- 2x3x3 Nos = 18Nos 11 Supsension Clamp for Single ACSR Moose Conductor For 132KV PTR Aux Bus Jumpers to LAS's 12 Pad Clamps Suitable for Twin Moose For 220KV Breakers Bays 3 Phases 3 Sides 2 18 Bays 2 Phases 3 Sides 1 6