CATALOUGE
CATALOUGE
Gauges
MODEL : SFBSPG (Dry Case)
LSBSPG (Liquid Filled Case)
Features
n Safety pattern
n All SS construction
n Theses Pressure Gauges are well suited for the Process
Industries such as Chemicals, Petro-chemicals, Energy or
Gas industry, Food processing, Nuclear etc.
n These Gauges have been provided with a solid baffle wall
and blow out back which immediately releases the pressure
in the enclosure in the event of an accidental rupture of the
sensing element.
Specifications Ranges
Ref. standard EN 837 Gauge bar, kg/cm2 Least count
Dial 100 mm /150 mm, Aluminium, white background, Vacuum (-)1 to 0 0.02
black markings -760 to 0mmHg 20
Case SS304 / SS316 with bayonet bezel
Protection Weatherproof to IP-68 (IS:13947 part I / IEC:60529) Compound (-)1 to 0.6 0.05
Window Safety glass (Shatter proof / Toughened glass) (-)1 to 1.5 0.05
Bourdon SS316, SS316 Ti, SS316L, Monel (-)1 to 3 0.10
Socket 22 mm Square in SS 316, SS316L, SS316 Ti, Monel (-) 1 to 5 0.10
Movement SS304, SS316 (-)1 to 9 0.20
Range As per EN 837 (refer table) minimum span (-)1 to 15 0.50
0.6 kg/cm2, maximum 1600 kg/cm2g (-)1 to 24 0.50
Connection 1/2" NPT (M) as standard* (other optional**) (-)1 to 39 1.0
Accuracy ±1% FSD (0.5% on request)
Pressure 0 to 0.6 0.01
Over range As per EN 837
Zero adjustment Micrometer Pointer Gauge 0 to 1 0.02
Blow out disc Provided at back of Case (‘C’ shaped 0 to 1.6 0.05
Temperature suitability Ambient (-)20°C to 60°C, Media 200°C Bourdon) 0 to 2.5 0.05
Temperature Effect Within ±0.4% FSD/10°C, when temperature changes from 0 to 4 0.10
reference temperature of 20°C (as per EN-837 standard) 0 to 6 0.10
Optional NACE compliance 0 to 10 0.20
Liquid filled case 0 to 16 0.50
External Knob for zero setting 0 to 25 0.50
IBR Certification 0 to 40 1.0
Vacuum Protection 0 to 60 1.0
CE
Pressure 0 to 100 2.0
Atex
Gauge 0 to 160 5.0
* For ranges above 1000 bar, connection shall be 1/2"BSP(M) Coil type 0 to 250 5.0
with Bottom Entry only Bourdon 0 to 400 10.0
0 to 600 10.0
** Autoclave connection available on request
0 to 800 20.0
0 to 1000 20.0
0 to 1600 50.0
0 to 2000 50.0
0 to 2500 50.0
For range other than above please contact our design dept.
The parameters mentioned here are the standard specifications / values generally used for most of the process applications. Any other specification not
appearing here also can be provided as per customer requirement. For higher temperature services above 100°C,
we recommend to provide suitable cooling arrangement (Syphon, Cooling Tower, Impulse Tubing, Diaphragm Seal etc.)
10/17 REV.: 00
MODEL
OPTION
BASIC MODEL CODE A05 Accuracy ±0.5%FSD
SFBSPG Dry Case ATX Atex
LSBSPG Liquid Filled Case BGS Built In Gauge Saver
BSN Built In Snubber
MOUNTING CLB Colour Band
V Bottom Entry, Local Mounting CEM CE marking
S Bottom Entry, Surface Mounting DC2 Silicone Oil filled Case
Y Bottom Entry, 2" Pipe Mounting DUS Dual Scale
C Back Entry, Local Mounting EXZ External Knob for Zero Adjustment
P Back Entry, Flush Panel Mounting FLG Flanged Process Conn
GLY Glycerine filled Case
DIAL SIZE IBR IBR
100 100 mm 150 150 mm MXP Maxima pointer with Acrylic Window
NAC NACE
CASE OXY O2 Cleaning
S4S SS 304 OR5 150% FSD Over range
S6S SS 316 PHD Phenolic / Plastic Dial
S4D SS DIAL (SS304)
S6D SS DIAL (SS316)
BOURDON VCP Vacuum Protection
S6S SS 316 L Nil
S6L SS 316L CSU Chemical Seal
S6T SS 316Ti ACC Accessory
MN4 Monel XXX Other
SOCKET UNIT
S6S SS 316 KSC kg/cm2(g)
S6L SS 316L BAR bar(g)
S6T SS 316Ti PSI psi(g)
MN4 Monel
KPA kPa(g)
MPA MPa(g)
MOVEMENT MBR mbar(g)
S4S SS 304
MMW mm WC(g)
S6S SS 316
CMW cm WC(g)
CONNECTION* MWC m WC(g)
INW inch WC(g)
Conn Code Size Code Type Code Male/ Female Code
MMH mm Hg(g)
Thread T 1/4” 06 NPS NS Male M
CMH cm Hg(g)
3/8” 10 NPT NT Female F
INH inch Hg(g)
1/2” 15 BSP BP
XXX Other (Please specify)
3/4” 20 BSPT BT
1” 25 JIS-PF PF RANGE
M20 M20 JIS-PT PT Please select from Table
Gas GS
R RR FLG - FLANGE
Rp RP Conn Code Size Code Rating# Code Facing Code
Pitch 1.5 C Flange F 1/2” 15 150 A RF RF
3/4” 20 300 B FF FF
e.g. For 1/2"NPT(M), Code: T15NTM
For M20x1.5 (F), Code: TM20CF 1” 25 600 C RTJ RJ
1-1/2” 40 900 D LT LT
* For Autoclave connection, please contact our design department 2” 50 1500 E LG LG
3” 80 2500 F
e.g. For 40 NB 300# RF flange, Model Code: F40BRF
10/17 REV.: 00
www.generalinstruments.co.in 10 www.general-gauges.com
Accessories
MODEL : ACC
Snubber (Pulsation Dampener) Syphons are used to protect pressure instruments from high temperature of the process
protects the pressure instruments from fluid. It helps to reduce the service temperature so that the pressure instrument is
pressure pulsations / rapid pressure exposed to lower temperature. Generally offered in 1/2” sch, 40 or 80 size (other sizes
fluctuation. Ideal for instruments which also can be offered on request). Standard connection is ½” NPT(F) x 1/2” NPT(M). Plain
undergo severe pressure pulsations end suitable for Butt welding can also be offered. Available in material like CS (A106),
like those located at pump discharge. SS304, SS316, P11 etc. IBR Certification can be offered as per customer requirement.
Available in materials like CS, SS304,
SS316, Monel etc.
Standard connection is 1/2” NPT(F) x
1/2” NPT(M) (other connection can be
offered as per customer requirement)
Gauge Saver (Pressure Limit Valve) Gauge Adaptors are used for Universal Adaptor (Swivel Adaptor)
is used where the process pressure connecting instruments and facilitates the positioning of the
exceeds the over range limit of the accessories having different type of Instrument during installation. Generally
pressure instrument. When the threads. Conversion from male to offered in material like SS304, SS316,
process pressure exceeds the pre- female threads and vice versa is Monel etc.
set pressure, Gauge Saver shuts off possible by selecting suitable adaptors. (Other material on request). Standard
the pressure to the instrument and Generally offered in material like SS304, connection is 1/2” NPT(F) x 1/2”
thereby prevents damage of the SS316, Monel etc. (Other material on NPT(M) (other connection on request)
sensing element and protects the request).
calibration. Generally minimum
setting offered is 1 kg/cm2g (lower
setting on request). Normally
offered in SS316 & Monel with
standard connection of 1/2” NPT(F)
x 1/2” NPT(M) (other material /
10/17 REV.: 00
connection on request)
MODEL
ACC-
ITEM DESCRIPTION
SNB Snubber OPTION
SYP Pig Tail Syphon IBR IBR*
SYU "U" Syphon NAC NACE
GSV Gauge Saver OXY O2 Cleaning
GAD Gauge Adaptor L Nil
SWA Swivel Adaptor XXX Other (Please specify)
Note: This catalogue indicates the general specifications used for most of the process applications.
Any other specification not appearing here also can be provided as per customer requirement.
10/17 REV.: 00
Features
Process fluids which are highly viscous or containing solid particles could plug or clog the Diaphragm Seal cavity on the process side of the
diaphragm. In order to overcome this difficulty, Flush Diaphragm Seal are used. In this design, since the Diaphragm is directly welded on the
Flange Face, there are no cavities or hidden ports where the process fluid can enter and clog the system.
Optionally, Flushing Ring (Spacer Ring) with 1/4” NPT(F) or 1/2” NPT(F) connection can be provided as per the requirement. Flushing
Connection enables the user to purge / flush out / clean the area below the diaphragm without removing the Seal from the process line.
Optional Feature
n Cooling Tower
n Capillary for Remote mounting of the Pressure Instrument
n Flushing Ring (Spacer Ring) for purging / cleaning the area below the diaphragm without removing the Seal from the process line.
n Stud / Nut & Gasket, for assembling the Diaphragm Seal with Process Flange.
Note: This catalogue indicates the general specifications used for most of the process applications.
Any other specification not appearing here also can be provided as per customer requirement.
10/17 REV.: 00
MODEL: CSU-
www.generalinstruments.co.in 79 www.general-gauges.com