The Draeger-Tube® System is a trusted gas detection technology that uses glass vials filled with chemical reagents to identify specific chemicals in the air. With over 200 different tubes available for measuring more than 500 gases and vapors, it offers accurate, easy-to-read, and maintenance-free operation. The system is designed for one-handed use with the Draeger accuro® pump, making it a flexible and fast solution for gas detection in industrial workplaces.

Uploaded by

boba17121988
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views6 pages

Drager Tubes

The Draeger-Tube® System is a trusted gas detection technology that uses glass vials filled with chemical reagents to identify specific chemicals in the air. With over 200 different tubes available for measuring more than 500 gases and vapors, it offers accurate, easy-to-read, and maintenance-free operation. The system is designed for one-handed use with the Draeger accuro® pump, making it a flexible and fast solution for gas detection in industrial workplaces.

Uploaded by

boba17121988
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Draeger-Tubes ®

and accuro Pump ®

Trusted Technology that’s


ahead of its time

Accurate

Easy to read

Flexible

Fast

Specific

Easy to use

Maintenance free

Multi-Gas Detector
accuro pump ®

One handed operation

What is the Draeger-Tube®


System?
Most Trusted
Draeger-Tubes® have been leading the
Draeger-Tubes® are glass vials filled way in gas detection for over 60 years.
with a chemical reagent that reacts to a
specific chemical or family of chemi-
cals. A calibrated 100 ml sample of air
is drawn through the tube with the
Draeger accuro® bellows pump. If
the targeted chemical(s) is present the
reagent in the tube changes color and
the length of the color change typically
indicates the measured concentration.
The Draeger-Tube® System is the
world’s most popular form of gas

Widest Range
detection.

Draeger: Over 200 different Draeger-Tubes®


Leading Detection are available for measuring over 500
Ever since 1937 when we introduced gases and vapors.
our first detector tube, Draeger has
been the world leader in the analysis of
gases and vapors in the industrial
workplace. Over the years we have
developed more tubes and detection
devices for more applications than
anyone else!
Our leading edge technology
has kept us on the forefront
of colorimetric detector
tubes thus providing
the most accurate
and specific results Hassle-Free
available.
Operation
No calibration, no lubrication, no special
maintenance. Always ready to go.
Draeger Short-term Detection Tubes
Description Measuring Range Order Code Description Measuring Range Order Code

Acetaldehyde 100/a 100-1,000 ppm 67 26 665 Chlorine 0.3/b 0.3-10 ppm 67 28 411
Acetic Acid 5/a 5-80 ppm 67 22 101 Chlorine 50/a 50-500 ppm CH 20701
Acetone 100/b 100-12,000 ppm CH 22901 Chlorobenzene 5/a (5) 5-200 ppm 67 28 761
Acid Test Qualitative 81 01 121 Chloroform 2/a (5) 2-10 ppm 67 28 861
Acrylonitrile 0.5/a (5) 0.5-20 ppm 67 28 591 Chloroformates 0.2/b 0.2-10 ppm 67 18 601
Air Current Tube Kit 4054388S Chloroprene 5/a 5-60 ppm 67 18 901
Air Current Tubes CH 25301 Chromic Acid 0.1/a (9) 0.1-0.5 mg/m3 67 28 681
Alcohol 25/a 50-4,000 ppm Isopropanol 81 01 631 Cyanide 2/a 2-15 mg/m3 67 28 791
25-5,000 ppm Methanol Cyanogen Chloride 0.25/a 0.25-5 ppm CH 19801
Alcohol 100/a 100-3,000 ppm CH 29701 Cyclohexane 100/a 100-1,500 ppm 67 25 201
Amine Test Qualitative 81 01 061 Cyclohexylamine 2/a 2-30 ppm 67 28 931
Ammonia 0.25/a 0.25-3 ppm 81 01 711 Diethyl Ether 100/a 100-4,000 ppm 67 30 501
Ammonia 2/a 2-30 ppm 67 33 231 Dimethyl Formamide 10/b 10-40 ppm 67 18 501
Ammonia 5/b 2.5-100 ppm 81 01 941 Dimethyl Sulfate 0.005/c (9) 0.005-0.05 ppm 67 18 701
Ammonia 5/a 5-700 ppm CH 20501 Dimethyl Sulfide 1/a (5) 1-15 ppm 67 28 451
Ammonia 0.5%/a 0.05-10 Vol.% CH 31901 Epichlorohydrin 5/b 5-50 ppm 67 28 111
Aniline 0.5/a 0.5-10 ppm 67 33 171 Ethyl Acetate 200/a 200-3,000 ppm CH 20201
Aniline 5/a 1-20 ppm CH 20401 Ethyl Benzene 30/a 30-600 ppm 67 28 381
Arsenic Trioxide 0.2/a 0.2 mg/m3 67 28 951 Ethylene 0.1/a (5) 0.2-5 ppm 81 01 331
Arsine 0.05/a 0.05-60 ppm CH 25001 Ethylene 50/a 50-2,500 ppm 67 28 051
Benzene 0.5/a 0.5-10 ppm 67 28 561 Ethylene Glycol 10 (5) 10-180 mg/m3 81 01 351
Benzene 0.5/c (5) specific 0.5-10 ppm 81 01 841 Ethylene Oxide 1/a (5) 1-15 ppm 67 28 961
Benzene 2/a (5) 2-60 ppm 81 01 231 Ethylene Oxide 25/a 25-500 ppm 67 28 241
Benzene 5/b 5-50 ppm 67 28 071 Ethyl Glycol Acetate 50/a 50-700 ppm 67 26 801
Benzene 15/a 15-420 ppm 81 01 741 Fluorine 0.1/a 0.1-2 ppm 81 01 491
Carbon Dioxide 100/a 100-3,000 ppm 81 01 811 Formaldehyde 0.2/a 0.2-5 ppm 67 33 081
Carbon Dioxide 0.1%/a 0.1-6 Vol.% CH 23501 Formaldehyde Activation extend to 0.04 ppm 81 01 141
tube (for use only in
Carbon Dioxide 0.5%/a 0.5-10 Vol.% CH 31401 conjunction with 0.2/a tube)
Carbon Dioxide 1%/a 1-20 Vol.% CH 25101 Formaldehyde 2/a 2-40 ppm 81 01 751
Carbon Dioxide 5%/A 5-60 Vol.% CH 20301 Formic Acid 1/a 1-15 ppm 67 22 701
Carbon Disulfide 3/a 3-95 ppm 81 01 891 Halogenated Hydrocarbons 100/a 100-2,800 ppm 81 01 601
Carbon Disulfide 30/a 32-3,200 ppm CH 23201 Hexane 100/a 50-3,000 ppm 67 28 391
Carbon Monoxide 2/a 2-300 ppm 67 33 051 Hydrazine 0.2/a 0.2-10 ppm 67 33 121
Carbon Monoxide 5/c 5-700 ppm CH 25601 Hydrazine 0.25/a 0.1-10 ppm CH 31801
Carbon Monoxide 8/a (only for CO in H2) 8-150 ppm CH 19701 Hydrocarbons 0.1%/b 0.1-1.3 Vol. % CH 26101
Carbon Monoxide 10/b 10-3,000 ppm CH 20601 Hydrocarbons 2 3-23 mg/l CH 25401
Carbon Monoxide 0.3%/b 0.3-7 Vol.% CH 29901 Hydrochloric Acid 1/a 1-10 ppm CH 29501
Carbon Monoxide 200/a + 200-2,500 ppm CO 67 18 301 Hydrochloric Acid 50/a 50-5,000 ppm 67 28 181
Carbon Dioxide 2%/a 2-12 Vol. % CO2
Hydrochloric Acid/Nitric Acid 1/a 1-10 ppm (HCL) 81 01 681
Carbon Pretubes CH 24101 1-15 ppm (HNO3)
Carbon Tetrachloride 0.2/b 0.2-70 ppm 81 01 791 Hydrocyanic Acid 2/a 2-150 ppm CH 25701
Carbon Tetrachloride 1/a (5) 1-15 ppm 81 01 021 Hydrogen 0.2%/a 0.2-2 Vol. % 81 01 511
Carbon Tetrachloride 5/c 5-50 ppm CH 27401 Hydrogen Fluoride 0.5/a 0.5-90 ppm 81 03 251
Chlorine 0.2/a 0.2-30 ppm CH 24301 Hydrogen Peroxide 0.1/a 0.1-3 ppm 81 01 041

Number in parenthesis indicates tests per box. Consult the VOICE® software or local Draeger representative for Extension of Range for tubes.
Bold/Italic font indicates SEI Certification
Description Measuring Range Order Code Description Measuring Range Order Code

Hydrogen Sulfide 0.2/a 0.2-5 ppm 81 01 461 Perchloroethylene 10/b 10-500 ppm CH 30701
Hydrogen Sulfide 0.2/b 0.2-6 ppm 81 01 991 Perchloroethylene 50/A 50-10,000 ppm 81 01 851
Hydrogen Sulfide 0.5/a 0.5-15 ppm 67 28 041 Petroleum Hydrocarbons 10/a 10-300 ppm (n-Octane) 81 01 691
Hydrogen Sulfide 1/d 1-200 ppm 81 01 831 Petroleum Hydrocarbons 100/a 100-2,500 ppm (n-Octane) 67 30 201
Hydrogen Sulfide 2/a 2-200 ppm 67 28 821 Phenol 1/b 1-20 ppm 81 01 641
Hydrogen Sulfide 2/b 1-60 ppm 81 01 961 Phosgene 0.02/a 0.02-1 ppm 81 01 521

Hydrogen Sulfide 5/b 5-600 ppm CH 29801 Phosgene 0.25/c 0.25-15 ppm CH 28301

Hydrogen Sulfide 100/a 100-2,000 ppm CH 29101 Phosphine 0.01/a 0.01-1 ppm 8101 611
Phosphine 0.1/a 0.1-4 ppm CH 31101
Hydrogen Sulfide 0.2%/A 0.2-7 Vol.% CH 28101
Phosphine 1/a 1-100 ppm 81 01 801
Hydrogen Sulfide 2%/a 2-40 Vol.% 81 01 211
Phosphine 25/a 25-10,000 ppm 81 01 621
Hydrogen Sulfide +
Sulfur Dioxide 0.2%/A 0.02-7 Vol.% CH 28201 Phosphine 50/a 15-1,000 ppm CH 21201
Mercaptan 0.1/a 0.1-2.5 ppm 81 03 281 Phosphoric Acid Esters 0.05/a 0.05 ppm 67 28 461
(Dimethyldichlorovinylphosphate)
Mercaptan 0.5/a 0.5-5 ppm 67 28 981
Polytest Qualitative CH 28401
Mercaptan 20/a 20-100 ppm 81 01 871
Pyridine 5/A 5 ppm 67 28 651
Mercury Vapor 0.1/b 0.05-2 mg/m3 CH 23101
Styrene 10/a 10-200 ppm 67 23 301
Methyl Acrylate 5/a 5-200 ppm 67 28 161
Styrene 10/b 10-250 ppm 67 33 141
Methyl Bromide 0.5/a 0.5-30 ppm 81 01 671
Styrene 50/a 50-400 ppm CH 27601
Methyl Bromide 3/a 3-100 ppm 67 28 211
Sulfur Dioxide 0.1/a 0.1-3 ppm 67 27 101
Methyl Bromide 5/b 5-50 ppm CH 27301
Sulfur Dioxide 0.5/a 0.5-25 ppm 67 28 491
Methylene Chloride 100/a 100-2,000 ppm 67 24 601
Sulfur Dioxide 1/a 1-25 ppm CH 31701
Natural Gas Test (Methane)(5) Qualitative CH 20001 Sulfur Dioxide 20/a 20-2,000 ppm CH 24201
Nickel Tetracarbonyl 0.1/a (9) 0.1-1 ppm CH 19501 Sulfur Dioxide 50/b 50-8,000 ppm 81 01 531
Nitric Acid 1/a 1-50 ppm 67 28 311 Sulfuric Acid 1/a (9) 1-5 mg/m3 67 28 781
Nitrogen Dioxide 0.5/c 0.5-25 ppm CH 30001 Tetrahydrothiophene 1/b (5) 1-10 ppm 8101 341
Nitrogen Dioxide 2/c 2-100 ppm 67 19 101 Thioether 1 mg/m3 CH 25803
Nitroglycol 0.25/a 0.25 ppm 67 18 201 Toluene 5/b 5-300 ppm 81 01 661
Nitrous Fumes 0.5/a 0.5-10 ppm CH 29401 Toluene 50a 50-400 ppm 81 01 701
Nitrous Fumes 2/a 2-100 ppm CH 31001 Toluene 100/a 100-1,800 ppm 81 01 731
Nitrous Fumes 20/a 20-500 ppm 67 24 001 Toluene Diisocyanate 0.02/A (9) 0.02-0.2 ppm 67 24 501
Nitrous Fumes 50/a 50-2,000 ppm 81 01 921 o-Toluidine 1/a 1-30 ppm 67 28 991
Nitrous Fumes 100/c 100-5,000 ppm CH 27701 Trichloroethane 50/d (5) 50-600 ppm CH 21101
Oil Mist 1/a 1-10 mg/m3 67 33 031 Trichloroethylene 2/a 2-250 ppm 67 28 541
Olefins 0.05%/a 0.06-3.2 Vol.% Propylene CH 31201 Trichloroethylene 10/a 50-2,000 ppm CH 24401
0.04-2.4 Vol.% Butylene Triethylamine 5/a 5-60 ppm 67 18 401
Organic Arsenic Compounds Vinyl Chloride 0.5/b 0.5-30 ppm 81 01 721
and Arsine 3 mg org. arsenic/m3 CH 26303
Vinyl Chloride 1/a 1-50 ppm 67 28 031
Organic Basic Nitrogen Compounds 1 mg/m3 CH 25903
Vinyl Chloride 100/a 100-3,000 ppm CH 19601
Oxygen 5%/C 5-23 Vol.% 81 03 261 Water Vapor 0.1/a 0.05-1 mg/L 81 01 321
Ozone 0.05/b 0.05-1.4 ppm 67 33 181 Water Vapor 1/a 0.5-18 mg/L 81 01 081
Ozone 10/a 10-300 ppm CH 21001 Water Vapor 1/b 1-40 mg/L 81 01 781
Pentane 100/a 100-1,500 ppm 67 24 701 Water Vapor 3/a 3-60 lbs/mmcf 81 03 031
Perchloroethylene 0.1/a 0.1-4 ppm 81 01 551 Water Vapor 50/a 50-1,000 lbs/mmcf 81 03 021
Perchloroethylene 2/a 2-300 ppm 81 01 501 Xylene 10/a 10-400 ppm 67 33 161

Bold/Italic font indicates SEI Certification


Draeger-Tubes ®

Leading detection

Accurate Fast Specific


Not all detector tubes are created One stroke tubes are not always Reagents used in Draeger-Tubes® are
equal! Draeger-Tubes® with the accuro faster! Though many Draeger-Tubes® chosen to provide not only the most
pump deliver the most accurate results. require more than one stroke, they accurate, but also the most specific
Many Draeger tubes offer a +/- 10% often provide measurement results results possible. Our use of prelayers
standard deviation on the results. This in less time. Not only do you get the on many tubes (like benzene) remove
is a result of our 60+ years of manufac- benefit of a quicker analysis; the other potential interfering gases (e.g.
turing colorimetric tubes and the con- larger sample volume provides better aromatic hydrocarbons) so you measure
sistent volume delivered by the bellows statistical accuracy. only the targeted chemical, getting only
pump design. Quality assurance is the results you want. This design
accomplished by individually calibrating Flexible enables you to measure specific gases
each batch of Draeger-Tubes®. Then Draeger-Tubes® simply deliver more! in a complex ambient background
every batch is tested at regular intervals, More gases and more measuring found in the measurement area.
throughout the two year shelf life, to ranges than any other manufacturer.
guarantee accuracy over the entire life Draeger offers over 200 tubes for Draeger-Tubes on Time
of the tubes. accurately measuring over 500 differ- We can deliver to most locations in
ent gases. You can measure ambient continental North America within
Easy to Read air for health and safety levels, optional 24 hours.
See the difference for yourself! The equipment allows you to measure
wider diameter of the Draeger-Tubes® stack gases, motor vehicle exhaust
makes it easier to read. Well-spaced components, pressurized gas line
graduation marks enable distinct and samples, compressed air contaminants,
decisive measurement results. Color and solvents in water samples. Other
changes to the reagents are well specialized tubes measure over a
defined over the entire length of period of hours or a complete work
the stain. Many Tubes offer a dual shift to indicate daily exposure levels.
calibrated scale so that you can
interpret the results without using
multiplication factors.
accuro pump kits
Trusted Technology

Hard-Side Kit Soft-Side Kit


Hard-Side Kit...................................................4056443 Soft-Side Kit ....................................................4053473 Maintenance Free
Draeger has made gas detection easy.
Unlike a piston pump, the accuro pump
requires no lubrication. The accuro® is
constructed of non-metallic, corrosion
resistant materials. It can’t be bent by
rough treatment and it withstands harsh
chemical environments. Draeger-Tubes®
are pre-calibrated for two years. The only
requisite on Draeger-Tubes® is that they
are stored out of direct sunlight and at a
Quantimeter 1000 temperature of less than 25°C (77°F).
Quantimeter 1000 ..........................................4500231 Any temperature-controlled office meets
Universal Charger ..........................................6806430
these conditions.
accuro 2000
accuro 2000 Kit ...............................................4500200
Draeger Safety, Inc
101 Technology Drive
Pittsburgh, PA 15275-1057
1-412-787-8383
Fax: 1-412-787-2207
Customer Service: 1-800-858-1737
Fax: 1-800-922-5519
Technical Support: 1-888-794-3806
Simultaneous Test Set Fax: 1-888-794-3807
Simultaneous Test Set I (inorganic) ............8101735 www.draeger.com
Simultaneous Test Set II (inorganic) ...........8101736
Simultaneous Test Set III (organic) .............8101770
HazMat Simultest Kit Draeger Canada Ltd.
HazMat Simultest Kit .....................................4056098 7555 Danbro Crescent
HazMat Simultest Kit (w/o pump)...............4056447 Mississauga, ON L5N 6P9
2 1-905-821-8988
Fax: 1-905-821-2565
Customer Service: 1-877-372-4371
1 Fax: 1-800-Fax-Tube

3
Draeger Safety S.A. de C.V.
4
Av. Peñuelas No. 5
Bodega No. 37
Accessories Fraccionamiento Industrial San Pedrito
(1) Deluxe Tube Opener................................6400010 Queretaro, Qro. C.P. 76148
(2) Motor Vehicle Probe...............................CH00214 Mexico
(3) Hot Air Probe...........................................CH00213 Tel: (52) 442-246-1113
(4) Extension Hose 3m..................................6400077
Civil Defense Simultest 10m.....................................6400078 Fax: (52) 442-246-1114

(CDS) Kit 15m ....................................6400079


Represented By:
CDS Kit..........................................................6400565S
CDS/HazMat Kit.............................................4056665
CDS Kit with Quantimeter & Charger .......4056570
CDS/HazMat Kit with ...................................4056528
Quantimeter & Charger

You might also like