0% found this document useful (0 votes)
62 views

neofleX TOF TOF_Spec Sheet_06-2024

The neofleX MALDI-TOF/TOF MS System is a benchtop mass spectrometer featuring ultrafast scanning and advanced imaging capabilities. It includes a BRUKER smartbeam™ 3D laser, a mass range of up to 500,000 m/z, and high mass accuracy and resolution for both linear and reflector modes. Designed for research use only, the system is equipped with a robust vacuum system and offers significant sensitivity for various applications.

Uploaded by

business orders
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
62 views

neofleX TOF TOF_Spec Sheet_06-2024

The neofleX MALDI-TOF/TOF MS System is a benchtop mass spectrometer featuring ultrafast scanning and advanced imaging capabilities. It includes a BRUKER smartbeam™ 3D laser, a mass range of up to 500,000 m/z, and high mass accuracy and resolution for both linear and reflector modes. Designed for research use only, the system is equipped with a robust vacuum system and offers significant sensitivity for various applications.

Uploaded by

business orders
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

AXIAL-TOF MS

neofleX MALDI-TOF/TOF MS System


Technical Specifications
Benchtop MALDI TOF/TOF Mass Spectrometer System with ultrafast scanning
Smartbeam 3D™ laser with up to 20 pixels per second at 20 µm, enhanced imaging
detectors in linear and reflector mode for imaging of MALDI HiPLEX-IHC and general
high-end MALDI applications.

Part Number 1907227

Technical Data
Size (L×W×H) Bench top:
▪ 157 cm × 71 cm × 73cm
▪ 62 in × 28 in × 29 in

Weight ▪ 270 kg / 595 lb

Vacuum System ▪ Turbomolecular pump with oil free pre-vacuum pump

MALDI Ion Source ▪ scoutMTP – microtiter plate format


▪ Self-aligning lens-pack for maximum uptime and easy maintenance
▪ Wrench-free source cleaning
▪ Ion acceleration up to ±20 kV

Laser ▪ BRUKER scanning smartbeam™ 3D laser, 355 nm wavelength


▪ Enabling True Pixel MALDI Imaging
▪ Minimum number of 1.0∙1010 laser shots
▪ Repetition rate up to 10 kHz

Ionization mode ▪ Positive and Negative Ion Modes

Ion Optics Effective Flight Length


▪ 124 cm Linear Mode
▪ 260 cm Reflector Mode

Acquisition Workstation hp Z4 / Win10 / FlexCompass 2025

System Certification CE, ETL


Level
Analytical Performance
Mass Range Up to 500,000 m/z

Mass Accuracy Linear Mode Reflector Mode


≤ 50 ppm with external calibrant ≤ 6 ppm with external calibrant
≤ 60 ppm with internal calibrant ≤ 1.5 ppm with internal calibrant

Resolving Power Linear Mode (Positive) Reflector Mode (Positive)


(FWHM) ≥ 5,000 @ m/z 2,465 (ACTH_clip [1-24]) ≥ 30,000 @ m/z 3,147 (Somatostatin)
Linear Mode (Negative) Reflector Mode (Negative)
≥ 4,000 @ m/z 2,465 (ACTH_clip [1-24]) ≥ 15,000 @ m/z 1,568 (Glu-Fib)

Mass Resolution* Linear Mode (Protein*) Reflector Mode (Peptide*)


(Protein/Peptide) ≥ 700 for Insulin (m/z 5,734) ≥ 12,000 for Bradykinin [2-9] (m/z 904)
≥ 1,000 for Myoglobin M2+ (m/z 8,476) ≥ 14,000 for ACTH_clip [1-17] (m/z 2,093)
≥ 1,200 for Cytochrome C (m/z 12,361) ≥ 20,000 for ACTH_clip [1-24]) (m/z 2,932)
≥ 1,100 for Myoglobin (m/z 16,952) ≥ 25,000 for ACTH_clip [7-38]) (m/z 3,657)
≥ 25,000 for ACTH_clip [1-39] (m/z 4,539)

Sensitivity Linear Mode Reflector Mode


▪ BSA (m/z 66,431) @ S/N ≥ 100:1 for ▪ [Glu1]-Fibrinopeptide B (m/z 1,570) @
< 500 fmol shown with 1,000 laser shots S/N ≥ 200:1 for 250 amol shown on
Bruker AnchorChip™ target with 2,000
laser shots

Imaging Up to 20 px/s at 20µm spatial resolution with enhanced imaging detectors.

TOF/TOF Acquisition
Max. usable laser speed 5000 Hz

MS/MS Sensitivity [Glu1]-Fib fragment (m/z 1,056) @ S/N ≥ 40:1 for 250 amol shown on Bruker
AnchorChip™ target with 2,000 laser shots

MS/MS Mass Accuracy Average Mass Error ≤ 0.025 Da for relevant fragments of [Glu1]-Fibrinopeptide B (m/z
1,570)

MS/MS fragment ≥ 1,500 for [Glu1]-Fib fragment m/z 175


resolution ≥ 3,000 for [Glu1]-Fib fragment m/z 684
≥ 5,000 for [Glu1]-Fib fragment m/z 1,056
≥ 7,000 for [Glu1]-Fib fragment m/z 1,441

Pre Cursor Ion Selector Precursor ion selection has a resolution of ≥ 500 FWHM
Resolution

High-energy CID-Method The following d-ions will appear in 1 pmol Substance P (m/z 1,347) spectra

Fragment d3(K) d5(Q) d6(Q) d10(L)

Mass 297.3 Da 522.4 Da 650.4 Da 1,129.6 Da

S/N of d6-fragment ≥ 30:1

* Mass resolution over broad mass range measured simultaneously with PAN™ technology.

RUO: For Research Use Only. Not for use in clinical diagnostic procedures.
We are continually improving products and reserve the right to change specifications without notice.
© Bruker Daltonics GmbH & Co. KG 06–2024

Bruker Daltonics GmbH & Co. KG Bruker Scientific LLC Online information
Bremen · Germany Billerica, MA · USA bruker.com
Phone +49 (0) 421-2205-0 Phone +1 (978) 663-3660

[email protected] – www.bruker.com

You might also like