0% found this document useful (0 votes)
7 views

Slab_Changeable - Sheet1

The document provides detailed design data for a two-way slab, including dimensions, material grades, load calculations, and reinforcement requirements. It outlines the bending moment coefficients, shear checks, and deflection checks, confirming the slab's safety under specified conditions. The final recommendation is to use a 120 mm thick slab with Ø10 mm rebar at specified spacings for reinforcement.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views

Slab_Changeable - Sheet1

The document provides detailed design data for a two-way slab, including dimensions, material grades, load calculations, and reinforcement requirements. It outlines the bending moment coefficients, shear checks, and deflection checks, confirming the slab's safety under specified conditions. The final recommendation is to use a 120 mm thick slab with Ø10 mm rebar at specified spacings for reinforcement.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Two Way Slab

1. DESIGN DATA

Longer span of the critical Slab (Ly) 4.15 m


Shorter span of the critical Slab (Lx) 3.62 m
Grade of concrete (fck) 45 N/mm2
Width of slab (b) 1000 mm
Grade of steel (fy) 415 N/mm2
Unit weight of marble 27 kN/m3
Unit weight of screed 20 kN/m3
Unit weight of plaster 20 kN/m3
Thickness of screed 25 mm
Thickness of plaster 12.5 mm
Assume thickness of slab (D) 120 mm
Effective depth of slab (d) 85 mm

2. BENDING MOMENT COEFFICIENT

Type of Slab Panel = 2 Adjacent Edges Discontinous


Aspect Ratio of the slab Considered Ly/Lx = 1.118

Bending Moment Coefficient For 1.1 For 1.2 For 1.118


Coeff for -ve moment, ẞx = 0.053 0.06 0.0506
Coeff for +ve moment, ẞx = 0.04 0.045 0.048
Coeff for -ve moment, ẞy= - - 0.047
Coeff for +ve moment, ẞy= - - 0.035

3. LOAD CALCULATION

Dead load of slab 3 kN/m^2


Dead load due to floor finish 1.5 kN/m2
Live load at slab 2 kN/m2
Total load 6.5 kN/m2
Factored design load 9.75 kN/m2
Factored design load per meter 9.75 kN/m2

4. MOMENT CALCULATION

Design -ve moment for short span, M_{x} = 9.857 KN - m


Design +ve moment for short span, M_{x} = 10.338 KN - m
Design -ve moment for long span, M_{y} = 11.456 KN - m
Design +ve moment for long span, M_{y} = 8.53 KN - m

5. CALCULATION OF REINFORCEMENT

Design for -ve reinforcement :


Along short span = 333.408 mm2
Along long span = 389.977 mm2
Design for +ve reinforcement :
Along short span = 350.346 mm2
Along long span = 287.024 mm2
Minimum reinforcement required= 288 mm2

Directions Bar Dia Provided (mm) Area Requires (mm2) Spacing Required (mm) Spacing Provided (mm) Area Provided (mm2)
Shorter Support 10 333.408 mm2 235.56 150 471.234
Shorter Mid 10 350.346 mm2 224.17 150 471.234
Longer Support 10 389.977 mm2 201.39 150 471.234
Longer Mid 10 288 mm2 272.7 150 471.234

6. CHECK FOR SHEAR

Shear coefficient = 1.00


Design shear force (Vu) = 21.79 KN
Nominal shear stress (Tv) = 0.18 N/mm²
Percent tension steel (Pt) = 0.4%
Shear strength of M25 concrete and 0.4% steel (Tc) = 0.45 N/mm²
Shear strength coefficient for(d<=150) ks = 1.30
Shear strength in slab (Tc) = 0.59 N/mm²
Maximum shear stress for M45 grade concrete Tc, max = 2.80 N/mm²
Safe in shear

7. CHECK FOR DEFLECTION:

Required tension reinforcement % for short span (Pt) = 0.18 %


Provided tension reinforcement % for short span (Pt) = 0.40 %
Basic value of span to effective depth (L/d)) ratio (a) = 20
Modification factor for span > 10m (β) = 1
Mu/bd²= 1.585
Steel stress of service (fs)= 172.44 N/mm²
Required modification factor for tension reinforcement = 1.85
Actual modification factor for tension reinforcement (y) = 2.00
Allowable short span to effective depth ratio (Lx/d) = 40.00
Calculated short span to effective depth ratio (Lx/d) = 36.92
Safe in deflection

8. SUMMARY

Grade of concrete = 45 MPa


Grade Of Steel = 415 MPa
Provide 120 mm thick slab with Ø10 mm rebar @ 150 mm c/c & Ø10 mm distribution rebar @ 150 mm c/c bar