ProTran2 Loadside Installation and Operating Instructions
ProTran2 Loadside Installation and Operating Instructions
INSTRUCTIONS
0
Residential Wattage Requirements
1
Warnings • Cautions
1
Reliance Installation and Operating Instructions
Key Components of the Reliance Transfer Switch
Figure 1
Circuit breakers. Each transfer switch circuit has a 1-in interchangeable circuit breaker
that protects the branch circuit when the circuit selector switch is in the GEN position. In
the LINE position, each branch circuit is protected by the breaker in the load center.
Circuit selector switches. These switches allow you to select either GEN (generator) or
LINE (utility) as the power source for the branch circuits that have been wired through the
transfer switch. The OFF position is generally not used, as a switch in the OFF position
removes that branch circuit from both utility and generator power.
Handle ties. Handle ties are used for 240-volt circuits or multi-wire branch circuits. They
may be removed for 120-volt circuits. See page 6 for instructions on removing and adding
handle ties.
Power inlet filler plate. This can be replaced with a power inlet that is included in the
suffix A and B models (see page 7 for installation instructions). The power cord from the
generator is plugged into this inlet. The inlet is supplied separately for indoor models to
encourage the use of a remote connection outdoors reducing the likelihood of running the
generator indoors which is extremely dangerous. If this indoor model is installed outdoors,
make sure it is installed in a dry location.
Circuit Breaker Compartment Cover. Remove to change circuit breakers. Also includes
a wiring space that can be used to hard-wire the unit to a remote power inlet box.
Analog wattmeters (suffix A and C models). These meters indicate the total load, in
watts, on each side of the generator when the generator is supplying power as follows:
The left meter measures the load on The right meter measures the load on
A, C, and E 6-circuit B, D and F 6-circuit
A,C,E, and G 8-circuit B,D,F and H 8-circuit
A, C, E, G and I 10-circuit B, D, F, H and J 10-circuit
Note: The watt meters will register only if power is being used from the generator.
2
Installation Instructions
Preparing for You will need the following items:
Installation Electric drill
Screwdriver
Wire cutters/stripper
Hammer
Four anchors and screws
6 or 10 yellow wire connectors (depending on the model)
4 red wire connectors for the 20A and 30A hard-wire models
The following five steps generally apply to all transfer switch installations. The transfer
switch may be installed on either side of the load center.
1. Turn off the main circuit breaker in the load center to ensure your
safety.
3
Warning: Failure to properly install a multi-wire branch circuit could result in
overloading the neutral wire.
The maximum number of circuits available and those that can be used for multi-wire
branch circuits depends on the model of the transfer switch as follows:
Model Max Available for multi-wire branch circuits
A304 Circ
4 Any two adjacent circuits.
A306, A506 6 Any two adjacent circuits.
A308 8 Any two adjacent circuits.
A310, A510 10 Any two adjacent circuits.
Figure 3
4
Installing 120-volt Circuits
Warning: Transfer switch circuits with 20 amp breakers must be installed on only
those branch circuits with 20 amp branch circuit breakers. Transfer switch circuits
with 15 amp breakers can be installed on 15 or 20 amp branch circuits. Do not
install any transfer switch circuit on branch circuits greater than 20 amps,
except in position A and B which maybe 30 amps.
Wire the most critical circuits first, starting with any circuit position on the transfer switch.
Let's assume that Switch C will be designated to supply power to the refrigerator.
1. Turn off the refrigerator circuit breaker. Loosen the screw that secures the wire to the
circuit breaker. Disconnect the wire from the circuit breaker.
2. On the transfer switch, find the black and red wires marked C.
3. Feed the red wire to the selected breaker, in this case the refrigerator breaker.
4. Cut the red wire C to a convenient length. Strip approximately 5/8" from the end of the
wire. Connect the red wire to the refrigerator circuit breaker and retighten the screw.
5. Cut the black wire C to a convenient length for aligning with the wire removed from the
refrigerator circuit breaker in step 1. Strip approximately 5/8" from the end of the wire.
6. Insert both wires (the wire removed from the circuit breaker in step 1 and the black
wire) into a yellow wire connector. Twist the connector tightly and push the wires back
into the wiring compartment of the load center.
This completes the installation of the transfer switch for your refrigerator.
Repeat steps 1-6 for each of the remaining considering the following:
• See the following section for 240-volt circuits and the removal of handle ties if 240-
volt circuits are not required.
• Remember to "balance the load"—dividing the appliances requiring higher
wattage between the left and right sides of the transfer switch.
Figure 4
5
Installing 240-volt Circuits
Any two adjacent circuit selector switches may be used for a double-pole 240-volt circuit.
Use a handle tie to connect the two circuit selector switches.
*Note: Circuits used for multi-wire branch circuits are not available for 240-volt
circuits
Removing handle tie(s). If there are no 240-volt or multi-wire circuits in the transfer
switch installation, handle-ties on the switches are not needed. To remove a handle tie,
place the handle-tied switches in a position opposite of the other switches. Rotate the
cylindrical spacer between the switches upward repeatedly until the threaded shaft is
exposed on the right switch. Grab the threaded shaft and continue to rotate the spacer
upward until the spacer is free, being carefully not to drop the spacer when it becomes
free. Remove the shaft from the switch. If the shaft is not exposed after several revolution
of the spacer, insert a small slot screwdriver in the hole in the right switch and continue
rotating the spacer upward while the screw driver prevents the shaft from rotating.
Adding handle ties. If additional ties are needed to accommodate additional 240-volt
or multi-wire circuits, they can be added to adjacent pairs of switches.
Warning: Transfer switch circuits with 20 amp breakers must be installed on only
those branch circuits with 20 amp branch circuit breakers. Transfer switch circuits
with 15 amp breakers can be installed on 15 or 20 amp branch circuits. Do not
install any transfer switch circuit on branch circuits greater than 20 amps,
except in position A and B which must be 30 amps.
6
Hard-wire Installation
"Hard-wire" installation to a power inlet box located remotely from the transfer switch (Figure
5) requires additional steps to complete the installation. The wire connections to the wires
from power inlet box are made in the circuit breaker compartment of the transfer switch.
Access the circuit breaker compartment by removing the two screws located on the sides of
the lower circuit breaker
compartment cover. Replace when
installation is complete.
When you have wired all the load circuits in the transfer switch, only the white neutral wire
and the green ground wire remain.
1. Insert the white neutral wire into an unused opening in the neutral bar in the load
center and tighten the screw (Figure 4).
2. Insert the green ground wire into an unused opening in the ground bar, if existing, and
tighten the screw. If no ground bar exists, insert the green wire into an unused hole in
the neutral bar and tighten the screw.
3. Replace the cover to the load center.
4 Fill in the chart on the transfer switch to identify your emergency circuits and
corresponding circuit numbers in the load center.
5 Return all load center branch circuit and main breakers to the "ON" position.
6 Move all circuit selector switches on the transfer switch to the
"LINE" position.
Installation is now complete.
7
Operating Instructions
Using your Reliance Transfer Switch and Your Portable Generator
8
Transferring from Generator Power to Utility Power
1. Return all circuit selector switches to the LINE position.
2. Follow the procedures in the generator owner's manual to turn off the generator.
3. Unplug the power cord.
Optional Power Inlet Catalog # PB30 PB30 PB50 PB30 PB30 PB50
*National Electrical
Manufacturer's Association
9
Transfer Switch Parts List
3
Warranty
Each Reliance transfer switch or accessory is
guaranteed against mechanical or electrical failure due
to manufacturing defects for a period of 60 months
following shipment from the factory. The
manufacturer's responsibility during this warranty
period is limited to repair or replacement, free of
charge, of products proving defective under normal use
or service when returned to the factory, transportation
charges prepaid. Guarantee is void on products that
have been subjected to improper installation, misuse,
alteration, abuse or unauthorized repair. The
manufacturer makes no warranty with respect to the
fitness of any goods for a user's particular application
and assumes no responsibility for proper selection and
installation of its products. This warranty is in lieu of all
other warranties, expressed or implied, and limits the
manufacturer's liability for damages to the cost of the
product. This warranty gives you specific legal rights,
and you may have other rights, which vary from state
to state.
10