0% found this document useful (0 votes)
27 views21 pages

BDF-40V268'362 - 40°C Freezer BIOBASE

The user manual for the BIOBASE BDF-40V268/362 -40℃ Freezer outlines essential safety instructions, operational guidelines, and maintenance procedures to ensure safe and effective use. It emphasizes the importance of using protective gear, following installation and usage protocols, and maintaining proper environmental conditions for optimal performance. Users are advised to consult authorized personnel for repairs and to avoid storing inappropriate items within the freezer to prevent damage and safety hazards.

Uploaded by

soporte03
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views21 pages

BDF-40V268'362 - 40°C Freezer BIOBASE

The user manual for the BIOBASE BDF-40V268/362 -40℃ Freezer outlines essential safety instructions, operational guidelines, and maintenance procedures to ensure safe and effective use. It emphasizes the importance of using protective gear, following installation and usage protocols, and maintaining proper environmental conditions for optimal performance. Users are advised to consult authorized personnel for repairs and to avoid storing inappropriate items within the freezer to prevent damage and safety hazards.

Uploaded by

soporte03
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 21

-40℃ Freezer

BDF-40V268/362
User Manual

BIOBASE GROUP
Version 2022.03
Statement
Thank you for choosing and using the product of BIOBASE. For your safe and convenient use and
reasonable maintenance of the product, please read the operation instruction carefully and keep it
properly for reference.
For damages of any instrument due to the fact that the user does not use the product according to the
instrument operating environment declared in the handbook or injuries due to the fact that
individual does not operate the product according to safety instructions,BIOBASE has no
obligations and responsibilities to be in charge of them.
The user must accomplish the following three points when using the product:
1. Always use protective devices correctly (including clothes, gloves, goggles, etc.);
2. Always adopt good health habits and operate strictly according to the product instruction;
3. Everyone is obliged to be in charge of one’ own safety.
Due to the fast product update of BIOBASE, there may be differences between function of the
product you bought and the function mentioned in the instruction, please in kind prevail.

Safety Instruction:
·Please read the handbook carefully when using the machine for the first time.
·The Freezer can only be operated by trained and authorized personnel.
·The maintenance of the equipment can only be accomplished by BIOBASE or agents authorized by
BIOBASE.
·if operator runs into conditions not mentioned in the instruction, please contact BIOBASE or
agents authorized by BIOBASE for inquirying correct processing method.
·please use accessories provided by BIOBASE. if user uses other accessories, BIOBASE will not
take charge ofgenerated negtive effects. however, the user can apply to BIOBASE to test and verify
that whether the accesories accord with the requirements of BIOBASE.
·It is necessary to inspect and maintain the Freezer at specified time intervals.
·The Freezer is strictly prohibited to store living things or other goods which have strict temperature
requirement and are unsuited for storage at constant temperature.
·The Freezer realizes refrigeration through the heat dissipation of the back surface (condenser). In
order to ensure normal operation and ventilation and heat dissipation, the back and the left and right
sides of the refrigerator body should be at least 30cm away from the wall and no barriers are
allowed to block the air inlet and the air outlet.
·In case of machine fault or power failure, the temperature in the Freezer will rise. If the machine
cannot be repaired in short period, please take out the stored goods and trannsfer them to other place
where accords with the storing temperature to avoid damages.

1
Content
Statement ............................................................................................................................................... 1
Content ...................................................................................................................................................2
1. Product Features ................................................................................................................................ 3
2. Diagram and Introduction of Product ................................................................................................ 4
3. Cautions on Safety ............................................................................................................................. 5
4. Cautions on Transporting ...................................................................................................................8
5. Cautions on Use ................................................................................................................................. 8
6. Cautions on Installation ..................................................................................................................... 9
6.1 Installation Environment ...............................................................................................9
6.2 Cautions ........................................................................................................................ 9
6.3 Installation Site ............................................................................................................. 9
7. Use ................................................................................................................................................... 10
7.1 Installation ...................................................................................................................10
7.2 Grounding ................................................................................................................... 10
7.3 Adjustment ..................................................................................................................10
7.4 Cautions ...................................................................................................................... 11
7.5 Forbidden .................................................................................................................... 11
8. Temperature regulation ....................................................................................................................12
8.1 Key function ................................................................................................................12
9. Parameter setting method .................................................................................................................13
9.2 Error display ................................................................................................................13
10. Routine Maintenance ..................................................................................................................... 15
10.1 Clean of incubator .....................................................................................................15
10.2 Defrost .......................................................................................................................15
11. Clearing of Fault and Maintenance Service ...................................................................................16
12. Main Performance Index ............................................................................................................... 17
12.1 Main technical parameters ........................................................................................ 17
12.2 Wiring Diagram ........................................................................................................ 17
13. Packing list .....................................................................................................................................18
14. Warranty ........................................................................................................................................ 19

2
1. Product Features
 Microcomputer digital thermostat, temperature is adjustable ranging -15℃~-40℃.
 Diversified protection functions (compressor time delay protection, compressor high
temperature protection) .
 The product is mainly used for storing blood plasma, biological materials, vaccine, electronic
devices and low temperature test for special materials etc.
 It is applicable for the laboratory of blood bank, hospital, quarantine station, university,
scientific research institute, electronic chemicals etc.
 Convenient for storing and taking with multi-layer and independent closed storage space.

It is possible that there’s difference between the mentioned functions in the User’s
Manual and the product you have purchased since the product updates fast, please
refer to the functions of your product if there’s any difference. Technical data is
subject to update without prior notice.

 Please see the real product for the appearance, color or pattern of the storage cabinet
 It is not allowed to use this storage cabinet for storing live animals and fresh flowers which
have strict requirements on temperature

3
2. Diagram and Introduction of Product

DiagramⅠ: Structural diagram

1-Top cover plate 2- USB 3- Thermostat 4-Upper panel

5-The probe box 6-Test hole 7- Shelf 8-Outer door

9-Inner door 10- Lock 11- Bottom panel 12- Universal casters

13- Caster

4
3. Cautions on Safety
This User’s Manual lists out the important safety regulations, please follow the safety regulations,
otherwise, the consequences shall be undertaken by you.
Please follow the cautions and regulations listed in this User’s Manual for avoiding possible injury
for the operator and any other.
“Caution”, “Forbidden” and “Warning” are shown as below:

Items marked with “Warning” are related with the safety of the product and operator, and
should be strictly followed.

Items marked with “Forbidden” must absolutely be forbidden, otherwise, it may possible cause
damage for the storage cabinet or physical safety for the operator.

This mark is marked on the cover of high voltage electric appliance for avoiding electric shock,
and this cover should be removed by qualified engineer or repair technician.

Please adopt the special power supply (AC 220V/50Hz) listed on the name plate of the
equipment. If the voltage is lower than 187V or higher than 242V, please install the 4000W or
higher automatic voltage stabilizer for the product. If the power cord should be extended, the
sectional area of the extended wire shall not be less than 2mm², and the length should not be longer
than 3m. It may possibly cause fore or electric shock if power supply of different voltage or
frequency which are not marked on the name plate is used.

The power cord of the storage cabinet has 3-line (grounding) plug, and standard 3-line
(grounding) socket. Please do not cut or remove the grounding pin of the power cord under any
condition. Please ensure that the plug of power cord tightly inserts into the socket with tight contact,
otherwise, it may possibly cause fire.

Please use power socket which is connected with grounding wire for avoiding electric shock.
If the power socket is not connected with the ground, please ask the qualified technician to install
grounding wire.

It requires installing independent overload and leakage protector at the power supply terminal
of this storage cabinet.

Do not drill on the surface of the storage cabinet, otherwise, it will seriously influence the
cooling performance of the storage cabinet.

Do not connect this equipment with the ground through gas pipe, water pipe, telephone wire or
lightning rod because above mentioned grounding will cause electric shock or other dangers.

Do not use the equipment in the open air. It may possibly cause electric leakage or electric
shock if the storage cabinet is wet with rain.

5
This equipment should only be installed by qualified technician, it may possibly cause electric
shock or fire if it is installed by disqualified technician.

Please install the equipment on the solid floor, if the floor is not solid or the installation place
is unsuitable, it may possible cause equipment overturn or physical injury.

Do not install the equipment in the damp site or place where may easily suffer from water,
otherwise, it may cause electric leakage or electric shock since the insulating quality will be
dropped.

Do not store flammable, explosive and dangerous products or volatile materials in the
equipment, do not use flammable mist near the equipment, otherwise, it may possibly cause
explosion or fire.

Do not store acid, alkali and corrosive materials in this equipment, otherwise, it may possibly
damage the internal components or electric parts of the equipment.

Do not insert metal products such as iron nail or wire into any hole and clearance of this
equipment or any outlet for internal air circulation, otherwise, it may possibly cause electric shock
or physical injury since the above objects may contact with the moving parts.

Please use this equipment in the safe area when it is used for toxic, harmful or radioactive
materials since incorrect use may possibly cause harm to human health the environment.

When there’s flammable gas leakage, please turn off the gas valve, open the doors and
windows for ventilation, please do not unplug or insert the power plug of the storage cabinet.

Please cut off power supply before equipment repair or maintenance for avoiding electric
shock or physical injury.

Ensure that the repair technician won’t inhale medicine or suspended particles in or
surrounding this equipment, otherwise, it may possibly cause harm to human health.

Do not directly pour water on the equipment, otherwise, it may cause electric shock or short
circuit.

Please do not disassemble, repair or refit this equipment by yourself. Any above work which is
not operated by the authorized technician may possibly cause fore or physical injury.

If the equipment doesn’t work normally, please cut off power supply. It may possibly cause
electric shock or fire if it keeps working under abnormal state.

If the equipment is kept in the open area for a long period, please ensure that children won’t

6
approach the equipment, and the cabinet door should not be closed completely.

Please do not supply power within 5 minutes if the power supply of the storage cabinet is cut
off, otherwise, it may possibly damage the compressor or system, please unplug the power plug
before repairing the equipment. Please do not roll, press or damage the power cord.

The abandoned equipment shall be handled by corresponding technician. Remove the cabinet
doors for avoiding accident such as suffocation.

Please hold the power plug instead of pulling the wire of plug when removing the plug from
the power socket, otherwise, it may possibly cause electric shock or fire caused by short circuit.

Please do not contact any electric part or switch such as power plug with wet hand, otherwise,
it may possibly cause electric shock.

When restart the equipment after power failure or cutting off power supply, please check the
settings of the equipment because the change of settings may possibly damage the stored materials.

Please do not put the container with water or heavy object on the equipment, otherwise, it may
possibly cause physical injury if the object falls down, and the water may drop the insulation quality
and result in electric leakage or electric shock.

Please do not climb on the equipment or put other objects on the equipment, otherwise, it may
possible cause physical injury or equipment damage if the equipment turns over.

Please do not store the glass bottle or filling container in the cabinet, otherwise, it may possibly
cause physical injury if the container is broken under low temperature.

Please do not directly contact the stored materials with hand, otherwise, it may possibly cause
frostbite if hand contacts the frozen material or internal wall of the equipment.

Please wear gloves when repairing the equipment for avoiding injury caused by the sharp edge
or corner.

If the equipment won’t be used for a long period, please unplug the power plug for avoiding
electric shock, electric leakage or fire caused by ageing power cord.

Keep plastic bag out of reach of children because plastic bag may possibly cause suffocation.

7
4. Cautions on Transporting
1. Please transport the storage cabinet with forklift or clip charter before unpacking.
If forklift is used, please insert from the bottom of wood support at the side of the storage cabinet
and then move the storage cabinet.
If the clip charter is used, please lift from the bottom of wood support, ensure clip the side of the
storage cabinet.
2. After unpacking, please push the storage cabinet for moving it.
Note: Please do not incline the storage cabinet by over 45° when transporting.
5. Cautions on Use
 When starting the storage cabinet for the first time or after stopping for a long period, please
test the battery, it is possible that the battery is under low power because the battery has been
safely discharged, it doesn’t mean that there’s fault. Under this condition, please fully charge
the battery, and keep the storage cabinet working continuously for about 10 hours.
 When the storage cabinet is working, the door frame of the cabinet may be hot, and it is not
fault. In order to prevent dew on the enclosure, defrosting pipes are installed around the cabinet.
 Before storing objects in the storage cabinet, please confirm that the temperature has dropped in
the cabinet, then put objects in it by batches for avoiding temperature rise.
 The temperature displayed is the temperature at the heat detector in the storing cabinet,
although it is possible that there’s difference between the displayed temperature and the actual
temperature in the middle of the storing cabinet, it will gradually reach the real temperature.
 Please clean the equipment with diluted and PH-balanced detergent (undiluted detergent may
damage the plastic parts. Please refer to the instructions of detergent for diluting it). Do not
clean the storage cabinet with brush, acid, gasoline, soap powder, polishing powder or hot
water, because above materials may possibly hurt the coating surface and plastic and rubber
parts. Please do not wipe the plastic and rubber parts with volatile solvent such as gasoline.
 After working for a period, frost may occur on the evaporator, if the frost is thick, it may
influence the cooling effect of the storage cabinet and increase electricity consumption,
therefore, please cut off power supply to remove frost when the frost is about 5mm thick.
 Before defrosting, please take out the objects from the cabinet and put the objects in the other
chamber for avoiding damaging the objects when the temperature rises.
 There’re a lot of cooling coils on the rack, please do not remove frost on the rack with sharp
tools such as knife, ice chisel or screwdriver. When removing frost, please do not scratch the
evaporating pipe, otherwise, it may cause equipment fault.
 If the storage cabinet won’t be used for a long period, please cut off power supply and turn off
the battery switch.
 In order to reach the best cooling effect, avoid frequently opening the first small door.

8
6. Cautions on Installation

6.1 Installation Environment


1. Environment temperature: 10℃~32℃, please use air conditioning system if necessary.
2. Environment humidity: <85% RH.
3. Avoid too much dust.
4. Avoid mechanical sway or vibration.
5. Input Voltage: <220V-±10%.
6.2 Cautions
1. Because low temperature equipment is relatively sensitive to the environment temperature. If the
equipment is installed in other environments and can’t work normally, please optimize the
environment.
2. It is not allowed to install the equipment in the open environment. It may possibly cause electric
leakage or electric shock if the storage cabinet is wet with rain.
6.3 Installation Site
In order to ensure normal work and obtain best performance, the site for installing the equipment
shall meet the followings:
1. Do not install it in the small and closed space, the door of the room shall not be less than this
product for avoiding difficult repair and storage objects damage when the equipment is fault.
2. Leave at least 30cm gap at four sides of the storage cabinet for ventilation.
3. The floor for installing the equipment must be smooth.
4. The site shall be well ventilated without direct sunlight.
5. Please do not share one socket with other equipment, ensure the plug and socket are connected
tightly.
6. Please do not twist or press the power cord.
7. To extend the power cord, the specification of the wire should be 230V-, 15A.
8. Please check the work voltage before use, take it into consideration to use voltage stabilizer in the
area with unstable voltage for assuring to stabilize the input voltage at 220V-±10%, the power of the
voltage stabilizer shall >3kW.
9. Ensure reliable grounding for this equipment.
10. If the power socket is installed with grounding wire, please check the grounding condition
before use.
11. If the socket is not installed with grounding wire, please install grounding wire by qualified
technician.
12. Please install the independent overload and leakage protector at the power supply terminal of the
storage cabinet.

9
7. Use

7.1 Installation
1. Remove packing materials and packing bag.
Remove all packing materials and packing bags.
2. Install the position limiting sheet metal.
Install the position limiting sheet metal at the rear side of the machine set.

Position Limiting Sheet Metal


Position Limiting Sheet Metal

7.2 Grounding
Please use power socket with grounding wire. If the socket is not installed with grounding wire,
please install grounding wire by qualified technician.
Do not connect this equipment with the ground through gas pipe, water pipe, telephone wire or
lightning rod because above mentioned grounding will cause electric shock.
After installing, the power socket must be approachable for conveniently unplug the power cord in
emergency. Do not cover the air outlet of the low temperature storage cabinet with any object.
7.3 Adjustment
Please refer to the following steps when use the equipment for the first time:
1. After installing the storage cabinet, please do not supply power within 24 hours.
2. When nothing is stored in the cabinet, connect the power cord with special socket of suitable
specification.
3. If there’s alarm sound, please press the SET button to stop alarm.
4. Set the desired storage cabinet temperature: when nothing is stored in the cabinet, supply power,
start the cabinet, observe that the storage cabinet may start and stop normally for over 24 hours,
which proves that the performance of the storage cabinet is normal.

10
5. After confirming normal performance of the storage cabinet, please store objects in the storage
cabinet.
7.4 Cautions
Please arrange full time technician to check and record the working conditions (record once every
2-4 hours), the temperature in the storage cabinet will rise if there’s fault or the cabinet is stopped,
please take out the objects if it can’t be repaired in a short period, and move the objects to the place
which meets the requirement on storage temperature for avoiding damaging the objects.
Before storing objects in the cabinet, please confirm that the desired temperature shall be accordant
with the temperature range of this product for avoiding damaging the objects and causing loss if the
temperature of the product can’t reach the requirement.
As a result of cooling inertia, there’s difference between the displayed temperature and the setting
temperature of the product (the lower the setting temperature, the lower the temperature difference),
which is normal.
7.5 Forbidden
All low temperature storage cabinets are the storage equipment, it is not allowed to put too much
and relatively hot objects into it, otherwise, it may cause constant working of compressor and bad
cooling effect, which may easily damage the compressor.
Please do not accelerate the defrosting process with any mechanical tool or other mode which is not
approved by the manufacturer.
Do not damage the cooling loop.
Do not use the electric appliance which is not approved by the manufacturer in the storage cabinet.
Operation after Cutting off Power Supply
The storage cabinet has memory function for the setting value, after power off, the equipment will
work according to the setting parameters before the last power failure.

11
8. Temperature regulation

8.1 Key function


The electric temperature controller is installed on the control panel of the Freezer. When power is
on, the digital display screen can display the actual temperature inside the refrigerator. The control
panel of the temperature controller is illustrated by the following diagram:

1-High temperature warning mark 2-Door opening warning mark


3-Battery status mark 4-Inside temperature display
5-Mute 6-Set 7-Up-regulation
8-Down-regulation 9-Defrost 10-On-off key of light
It is recommended not to adjust the setting temperature at random when it is in normal use.
Otherwise, the high temperature (AH) alarm or the constant temperature (AL) alarm will be
stimulated, during which, please adjust the high, constant temperature alarm (AH, AL) values at the
same time.
Mute key: when the alarm sound prompt needs to be canceled, we can cancel the voice prompt by
pressing the mute key, but the alarm indicator and the alarm code will always show until the alarm
state is released.
USB:Insert the USB flash drive, the uP symbol on the display is lit, indicating that the data starts to
be stored; when the End symbol on the display is lit, indicating that the data storage is completed,
and the USB flash drive can be taken out.The format for the file exported is csv, which can be read
by Excel.The data storage capacity is 8000 pieces/month, and the data will be rolled over after the
limit is exceeded, and the data can be stored for up to 10 years (120 months).

12
9. Parameter setting method
9.1 When the power of the Freezer is on, the display screen displays the inside current temperature
value. If the set temperature has to be readjusted, for example, the original set temperature is -40℃
which now has be to be adjusted to -30℃, please operates according to the following steps:
Serial No. Keys Operation Display
1 Displays the inside temperature
2 Displays that the initial set value is -40℃ and
twinkles
Press the Set key for 3
seconds

3 Figure increases
Press the Up-regulation key
4 Press the Down-regulation Figure decreases

key
5 Figure is -30℃
6 Saves the user settings and displays the inside
temperature
Press the Set key for 3
seconds
Notes: If there is indeed parameter change requirement, please contact the after-sale and distributors
of BIOBASE for setting.
Notes: When working normally,simultaneously press the down-regulation key and Defrost key for 5
seconds, enter the page of setting time parameter value, the default page displays t (min).The
corresponding parameters of H (hour), D (day), M (month), and Y (year) were displayed
respectively after press the up-regulation key.Select the parameters that needed to be adjusted, press
the set key and the digital tube flickers, adjust the parameters by pressing the up-regulation key or
down-regulation key, then press the set key to save the current parameter value. In the process, if
the down-regulation key and Defrost key are pressed at the same time, the temperature display
interface is restored.
9.2 Error display
When faults of the refrigerator temperature display probe including short circuit, open circuit,
malfunction and incorrect connection appear, “E0” is displayed. When faults of the refrigerator
temperature control probe including short circuit, open circuit, malfunction and incorrect connection
appear, “E1” is displayed. At the same time, the buzzer of the temperature controller will give out
alarm and the display screen displays corresponding alarm parameters (E0、E1).
After the power is switched off, the control function of the controller fails and the back-up source is
used for displaying. If the back-up source is charged for more than 10 hours, the power failure
symbol “Pd”, the current inside temperature and the alarm display alternatively for one time and
then display again after 30 seconds’ stop for cycle operation. After 8 hours, the nixie tube stops
displaying. The high temperature alarm mark light will twinkle continuously until the electric
quantity of the back-up source is used up. The inside temperature can be continuously displayed
during the power failure. Please pay attention to this and take relevant measures to avoid damages.
Suggest: If you judge that the temperature sensing probe goes wrong, you should cut off the power
and first check whether the connecting wire of the temperature sensing probe is loose. Please

13
contact professional after-sale personnel or distributor of BIOBASE for processing.
Tips: if internal code appears when user regulates the temperature controller, the user should wait
for 1 minute and then operate it till the inside temperature is displayed to avoid fault of the Freezer
caused by the change of the control parameter.
When the Freezer stalls temporarily due to power failure or other faults, the inside temperature of
the Freezer will rise from 5℃to 15℃ within 1 hour. If power cannot be supplied in short time, the
user should consider taking out the stored goods and putting them into other normal Freezers for
storing to avoid losses caused by the damages of the stored goods.
Before putting goods into the Freezer to be stored, the user should confirm in advance that whether
inside temperature of the Freezer is in accordance with the set temperature for storing to avoid
losses caused by goods damages due to the improper temperature.
Due to the refrigeration inertia, the Freezer cannot be kept at constant temperature. And there is
certain up and down difference between the inside temperature and the set temperature. The inside
temperature varies with the change of the service environment and the set temperature. It belongs to
normal phenomenon.

14
10. Routine Maintenance
In routine maintenance, in order to prevent electric shock or personnel injuries, be sure to cut off the
power before repairing or maintaining the equipment and do not inhale drugs or particulate matters
surrounding the equipment when maintaining the equipment. It is necessary to dry wet gloves to
protect your hands. Otherwise, your hands may be cut by edges or corners of the refrigerator body.
10.1 Clean of incubator
·The Freezer should be cleaned once every month. Regular cleaning may keep the appearance of the
incubator new;
·Use dry cloth to wipe off a small amount of dust on the housing, the inner chamber and all
accessories of the Freezer. If the Freezer is very dirty, it is advised to use neutral detergent for
cleaning;
·After cleaning, use cloth which has been soaked in clean water to wipe off the detergent;
·Do not pour water on the housing or in the preserve room of the Freezer. Otherwise, the electrical
insulation may be damaged, thereby causing faults.
10.2 Defrost
Frost is generally in the box partition and inside the box wall, frost may cause gaps between the box
body and the door seal, causing poor refrigeration effect, should be cut off for defrost, the following
steps is by removing the empty box body defrost method.
Note: Please use the defrosting shovel in the attachment for manual defrosting. Do not use knives or
screwdrivers with sharp corners to defrost, so as not to damage the box.
1. Take out the contents of the box and transfer them to another storage box, or put them in a
container with frozen liquid carbon dioxide.
2. Turn off the power switch.
3. If there is a small door, please open the small door and leave the outer door of the refrigerator
open for a period of time so as to melt the frost.
4. Dry the water from the bottom of the box with a dry cloth.
5. After cleaning the box, restart the equipment.
6. Put the item back into the cooled box.

15
11. Clearing of Fault and Maintenance Service
Some abnormal conditions of the Freezer are caused by misuse. Before you commit maintenance,
please compare with the following table for self inspection and exclusion.
Problems Reasons and Solving Measures

·If the power socket has electricity?


·If the power socket is plugged or loosened?
Freezer does not work
·If the power fuse is disconnected?
·If the supply voltage is too low or too high?

Compressor breaks down ·If the temperature setting is right?

Temperature goes on decreasing


·If the temperature setting is right?
after reaching to the set value

·If the fan stops running?


·If the door is not closed tight or opened too frequently?
Temperature cannot reach the set
·If too many goods are put in at one time and if the air
value
channel is blocked off?
·If the environment temperature is too high?

·If the refrigerator body is placed at the flat ground?


·If the refrigerator body touches the wall?
Too much noise
·If the incubator immediately enters operating state after
being started?
If you cannot judge the fault cause or debug, please contact the local or nearby appointed service
center according to the instruction of the warranty certificate (standard accessory) and tell use your
name, address, phone number, type of the Freezer, purchase time, fault phenomenon, etc.
Professional engineer will offer warmhearted service to you.

16
12. Main Performance Index

12.1 Main technical parameters

Model BDF-40V268 BDF-40V362

Climate type N/SN N/SN

Temp(℃) -15~-40 -15~-40

Volume(L) 268 362

Power supply 220V~50Hz 220V~50Hz

Refrigerant R290 R290

Dimension(mm) 690×744×1631 690×744×1885

12.2 Wiring Diagram

FM= Condenser Fan CM=Compressor SR= Starting Relay


EC= Thermostat DS= Door Switch TS=Temperature Probe

17
13. Packing list

Model BDF-40V268 BDF-40V362

User Instruction 1 1

Key 2 2

Position Limiting Sheet Metal 2 2

Shelf 3 4

Bolt 4 4

Fuse(10A) 2 2

Power Cord 1 1

18
14. Warranty
 If the instrument and equipment during the warranty period fails or damages due to improper
use by the user, our company shall not bear the warranty obligation.
 After the warranty period, our company is also responsible for the maintenance, but the
corresponding maintenance fee will be charged.
 For the production date, please refer to the product label.
 We can provide the drawings and some necessary technical data for the maintenance units and
maintenance personnel trained and approved by our company.
1. From the date of purchase, the user can enjoy one-year free warranty for the whole machine and
three-years warranty for the compressor (man-made damage is not within the scope of warranty),
and the purchase time is subject to the valid purchase documents.
2. The following situations are not within the scope of warranty, only maintenance services are
provided, but corresponding cost are charged.
(1) All damages caused by human factors, including damages caused by using in abnormal working
environment, not following the user manual and improper operation, etc.
(2) If the user disassembles, repairs or refits the machine without permission, or the device is not
repaired by the authorized unit of our company, or there is no warranty card or valid document.
(3) Damage caused by improper transportation or other irresistible factors (such as flood, fire,
lightning, earthquake, etc.) after purchase.

19
JINAN BIOBASE BIOTECH CO., LTD.

ADDRESS: North Side of Jiwang Road, Mingshui Economic DevelopmentDistrict, Zhangqiu, Jinan
City

Tel: +86-531-81307661

Inquiry: [email protected]

Complaints: [email protected]

After-sales service: [email protected]; [email protected]

Web:www.biobase.cc/www.meihuatrade.com/www.biobase.com