Pressure transmitter
CP 300
New
• Ranges from 0/+10 Pa to -10 000/+10 000 Pa (according to model)
• Transmitter resolution at 0.1 Pa on CP 301 (optional)
• Configurable intermediate and centre zero ranges
• Air velocity and airflow functions (optional)
• Interchangeable measuring sensor (SPI technology)
• Simultaneous display of 1 to 4 parameters
• External transmitter inputs (KIMO Class 200 and 300) and thermocouple K
• 2 outputs 4-20 mA (4 wires) or 0-10V, RS 232, 2 RCR relays 6 A/230 Vac
• 2 visual (dual color LED) and audible (buzzer - 80 dB) alarms
• Output diagnostics
• MODBUS network RS 485 system (optional)
• ABS or ALU IP 65 housing, with or without backlit graphic display
• Quick and easy mounting using “1/4 turn” system with wall-mounting plate
Protection ...............................IP65
Display ....................................graphic from 1 to 4-line, 70 mm x 38 mm
.....................................................backlit, protection screen made of PMMA
Fittings....................................barbed fittings Ø 6,2 mm
100 mm
Self calibration
Thanks to the temperature compensation of the gain (from 0 to 50°C) and to the self
calibration system, Class 300 transmitters guarantee an excellent long-term
stability, along with a great measurement accuracy.
Air velocity calculation function : Self calibration principle : the microprocessor drives an electro-valve that
compensates for any long-term drift of the sensitive element.
Air velocity (m/s) = CM x CC x CT x D
pressure Pa) Compensation is made by regular automatic adjustment of the zero. True differential
pressure measurement is then made regardless of the environmental conditions of
CM : cœfficient of the differential probe the transmitter.
CC : coefficient to adapt the measuring system to the specifications of
your air movement conditions . Electro-valve lifetime .....................100-million cycles
CT : temperature compensation coefficient, with the formula below :
Benefit..............................................no zero drift
CT =
574,2 x temp. (°C) + 156842,77 Self calibration frequency .............can be disabled or set between 1 and 60 min
101325
Power supply
a terminal block
i 24 Vdc / ac
230 Vac
115 Vac
The ticked box shows
the power supply type
of the transmitter.
e
RS 232 connector Pressure f
connections Thermocouple K
input
d c b g Connection fittings
{
{
Analogue output 1 Analogue output 2
RS485
(Modbus) Relay 1 Relay 2 a or a or a
ge ag
e B A For 24 Vdc For 24 Vac For 230 Vac 115 Vac
o lta nd olt und - + power supply models power supply models power supply models
. . v ou t . v
... r n ... ro nt
. . ... .....g urre . . ... ...g rre
en n
. ... ..c . . .. u pe
... ... ... ..c op yo
V ...... ...... V ...... ...... all
y
ed all _
10 .. ... 10 .. .. ed
m + ~ ~
0- D . A 0- D . A .
m
or mon clos n or mon clos
N m N m .. .n
ly .. . m ly
G 20 G 20 ... ..co mal
m ... ..co mal phase
4- 4- NO M. nor NO M. nor security earth
.. ..
CO .... CO .... neutral
NC NC
- 1 NC *
24 Vdc 2 NC *
power supply
3 NC *
+
4 B- (RS 485)
• For 24 Vac power supply models :
Output connection : 5 A+ (RS 485)
Vac Vac
• 4-20mA current output : 6 NC *
Power supply ~ ~ N L
0-10 V GND 4-20 mA
terminal block
7 NC *
OR -
Output 8 NC *
+
terminal block
Pe
9 RX (RS 232)
N ~ Pe 10 NC *
230 Vac 24 Vac
L
N N Regulator display - 11 TX (RS 232)
~ 230 Vac 24 Vac
or PLC/BMS
L Ph +
power supply
passive type 12 NC *
Class II power supply
13 NC *
• For 115 or 230 Vac power supply models : • 0-10 V voltage output : 14 NC *
ground Phase 0-10 V GND 4-20 mA
Neutral 15 GND (RS 232)
Output -
+
terminal block
Power supply ! CAUTION ! :
terminal block NC * = DO NOT CONNECT
Regulator display +
or PLC/BMS
115 / 230 Vac
passive type -
power supply
Ref. FT ang - CP 300 - 16/08/11 - RCS (24) Périgueux 349 282 095 Non-contractual document - We reserve the right to modify the characteristics of our products without prior notice.
• Class 300 transmitters can be linked Calibration certificates are offered as an option.
RS 232
in one network, on a RS 485 home • The SPI sensitive elements (interchangeable pressure probes)
bus. They can also are supplied with adjusting certificates.
be integrated into
an existing
network. RS 485 Mounting
To install the transmitter on a wall : fix the stainless steel plate to the
RS 232 wall (this plate is supplied with the transmitter). Drilling : 8 mm (with
the screws and wall-plugs supplied with
• When a Class 200 or 300 transmitter the transmitter). Insert the transmitter on
is connected to a CP 300 (with RS 232 the plate (see A on the drawing shown
connection), all the measurements can be given to the PLC/BMS via the beside) by aligning it at 30°. Rotate its
RS 485, with only one address for the 2 transmitters. housing in clockwise direction until you
hear a “click” which confirms that the
transmitter is correctly installed. Then,
• The RS 485 digital communication is a 2-wire network, on which the open the housing, lock the clamping
transmitters are connected in parallel. They are connected to a PLC/BMS via the system of the housing on the plate, with the screw as shown. (to
RTU Modbus communication system. Since the CP 300 can be configured with remove the transmitter from the plate, remember to remove the
the keypad, the MODBUS enables remote configuration, to measure 1 or 2 screw first). 120 mm
parameters or to see the status of the alarms...
Stainless
steel A
65 mm
98 mm
plate
Configuration A
You can configure all the parameters of the transmitter : units, measuring
65 mm Ø 5,4 mm
ranges, alarms, outputs, channels, calculation formula.... via the different
methods shown below. ! CAUTION !
Via keypad : only on models with display When the transmitter is installed and powered on, it will
automatically perform an autozero procedure. This guarantees
A code-locking system for keypad guarantees the security of the that the transmitter works properly, whatever its position.
installation. See configuration manual.
Via remote control (optional) only on models with display.
This is convenient to configure the transmitters located in hard to reach Maintenance
positions. Same method as with a keypad. Avoid aggressive solvents.
Via software (optional) : on all models. Protect the transmitter and probes from any cleaning product
Simple and user-friendly configuration. See LCC-300 user manual. containing formol, which may be used for cleaning rooms or
Via MODBUS (optional) : on all models. ducts.
Configuration of all parameters from your PC, via the supervision or data Options
acquisition software.
SQR/2 (square root extraction) function for
Configurable analogue outputs the calculation of air velocity and airflow
Configure the range according to your needs : outputs are automatically adjusted Digital output for Modbus network (RS 485 system)
to the new measuring ranges. LCC-300 configuration software with RS 232 cable
Range +100
-100 0 (Pa, mmH2O...)
Infrared remote control for configuration (only for models
Range with centre zero (-50/0/+50 Pa), with display)
with offset zero (-30/0/+70Pa) or Calibration certificate.
standard range (0 /+100 Pa) => you can 0V 10V
20 mA
Transmitter resolution at 0.1 Pa (CP 301)
4 mA
configure your own intermediate ranges
according to your needs, between 10% New range Optional accessories
+100
and 100% of the full scale. The minimum -100 0 50 (Pa, mmH2O...) Pitot tubes Sliding fittings
configurable range is 10% of the full Debimo measuring blades Connection gland
scale. Thermocouple K probes Clear tube
0V 10V Mounting brackets Through-connections
4 mA 20 mA
Pressure connections