0% found this document useful (0 votes)
23 views4 pages

Comen M300 V Specifications

The M300-V syringe pump by Shenzhen Comen Medical Instruments offers multiple working modes including Rate, Time, Weight, and Interval modes, with a flow rate range of 0.10ml/h to 2200.00ml/h depending on syringe size. It features a 4.3” touch screen, rechargeable lithium-ion battery, and operates in a temperature range of 5~40℃ with a humidity of 15~95%. The device includes various safety alarms, a dual-channel system, and supports USB software updates.

Uploaded by

ventas.seemid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views4 pages

Comen M300 V Specifications

The M300-V syringe pump by Shenzhen Comen Medical Instruments offers multiple working modes including Rate, Time, Weight, and Interval modes, with a flow rate range of 0.10ml/h to 2200.00ml/h depending on syringe size. It features a 4.3” touch screen, rechargeable lithium-ion battery, and operates in a temperature range of 5~40℃ with a humidity of 15~95%. The device includes various safety alarms, a dual-channel system, and supports USB software updates.

Uploaded by

ventas.seemid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Specifications: M300-V

SHENZHEN COMEN MEDICAL INSTRUMENTS CO.,LTD


Floor 10, Floor 11 and Section C of Floor 12 of Building 1A &
Floor 1 to Floor 5 of Building 2, FIYTA Timepiece Building, Nanhuan
Avenue, Matian Sub-district, Guangming District, Shenzhen,
Guangdong, 518106,P.R. China
Tel: +86-755-26408879
Fax: +86-755-26431232
Email: [email protected]
Web: www.comen.com

2022V 1.2
Syringe pump
M300-V

Working modes
Rate mode, Time mode, Weight mode, Interval mode,
Step: 0.01ml/h
Ramp mode, Sequential mode, Micro mode, TIVA mode,
20ml 0.10ml/h~600.00ml/h
First dose mode
Step: 0.01ml/h
Physical Characteristics
30ml 0.10ml/h~1200.00ml/h
Size: 300mm×145mm×130mm
Step: 0.01ml/h
Weight 2 kg
50/60ml 0.10ml/h~2200.00ml/h
Screen Size: 4.3” touch screen
Step: 0.01ml/h;
resolution 480 × 272
Preset range 0.10~9999.99ml; Step: 0.01ml
Operation Environment
Time mode setting range:
Temperature: 5~40℃
Time range: 00:00:01~99:59:59(h: m: s);
Humidity: 15~95% (non-condensing)
Step: 1s
Power requirement: 100-240V~, 50/60Hz±1Hz
Preset range 0.10~9999.99ml; Step: 0.01ml
Battery Type: Rechargeable Lithium-ion
battery
When the preset unit is Drug concentration or
Battery Capacity: 2200mAh
not milliliters (dosage, liquid dosage), preset
Battery Recharging
dosage and time can be set,
Time: Maximum 4 hours for
and the rate can be
charging
automatically converted
(power off)
Time range: 00:00:01~99:59:59(h: m: s);
Battery backup: 8 hours for continuous
Step: 1s
working (at 5ml/h)
Preset range 0.10~9999.99ml; Step: 0.01ml
Indicator:
Drug concentration
Alarm indicator
setting range 0.001~999.999ml; Step:
Power indicator
0.01ml; Unit: g, mg, ug, ng, U,
Battery indicator
IU, KU
Interfacing
Medicine volume
AC power interface
setting range 0.10~9999.99ml; Step: 0.01ml
RJ45
Weight mode setting range:
Multi-functional connector Parameter The patient's weight, drug
USB concentration or (Medicine
Modes: volume, liquid drug volume),
Rate mode setting range: dose rate, preset volume can
5ml 0.10ml/h~100.00ml/h be set, and the injection rate
Step: 0.01ml/h is automatically calculated
10ml 0.10ml/h~300.00ml/h
according to the parameters Step: 0.01ml/h
set above. 50/60ml 0.10ml/h~2200.00ml/h
Weight range: 0.10~500.00kg; Step: 0.01kg Step: 0.01ml/h;
Preset range 0.10~9999.99ml; Step: 0.01ml Preset range 0.10~9999.99ml; Step: 0.01ml
Drug concentration Time (Total time, up
setting range 0.001~9999.999ml; Step: time, down time) range
0.001ml; Unit: g/ml, mg/ml, 00:00:01~99:59:59(h: m: s);
ug/ml, ng/ml, U/ml, IU/ml, Step: 1s
KU/ml
Medicine volume Sequential mode setting range:
setting range 0.001~999.999; Step: 0.001; 5ml 0.10ml/h~100.00ml/h
Unit: g, mg, ug, ng, U, IU, KU Step: 0.01ml/h
Liquid drug volume 10ml 0.10ml/h~300.00ml/h
setting range 0.10~9999.99ml; Step: Step: 0.01ml/h
0.01ml; 20ml 0.10ml/h~600.00ml/h
Dose rate setting range Step: 0.01ml/h
0.001~999.999; Step: 0.001; 30ml 0.10ml/h~1200.00ml/h
Unit: g/kg/h, mg/kg/h, Step: 0.01ml/h
ug/kg/h, g/kg/min, 50/60ml 0.10ml/h~2200.00ml/h
mg/kg/min, ug/kg/min Step: 0.01ml/h;
Interval mode setting range: Preset range 0.10~9999.99ml; Step: 0.01ml
5ml 0.10ml/h~100.00ml/h Time range 00:00:01~99:59:59(h: m: s);
Step: 0.01ml/h Step: 1s
10ml 0.10ml/h~300.00ml/h Micro mode setting range:
Step: 0.01ml/h Preset range 0.10~9999.99ml; Step: 0.01ml
20ml 0.10ml/h~600.00ml/h Speed setting range 0.10~100.00ml/h; Step:
Step: 0.01ml/h 0.01ml;
30ml 0.10ml/h~1200.00ml/h TIVA mode setting range:
Step: 0.01ml/h Parameter settings Patient weight, drug
50/60ml 0.10ml/h~2200.00ml/h concentration, drug volume,
Step: 0.01ml/h; induction parameters
Preset range 0.10~9999.99ml; Step: 0.01ml (induction volume, induction
Interval time range: 00:00:01~99:59:59(h: m: s); time), maintenance
Step: 1s parameters
Interval speed setting Weight range: 0.10~500.00kg; Step: 0.01kg
range 0.001~999.999; Step: 0.001; First dose mode setting range:
Unit: g/kg/h, mg/kg/h, 5ml 0.10ml/h~100.00ml/h
ug/kg/h, g/kg/min, Step: 0.01ml/h
mg/kg/min, ug/kg/min 10ml 0.10ml/h~300.00ml/h
Ramp mode setting range: Step: 0.01ml/h
5ml 0.10ml/h~100.00ml/h 20ml 0.10ml/h~600.00ml/h
Step: 0.01ml/h Step: 0.01ml/h
10ml 0.10ml/h~300.00ml/h 30ml 0.10ml/h~1200.00ml/h
Step: 0.01ml/h Step: 0.01ml/h
20ml 0.10ml/h~600.00ml/h 50/60ml 0.10ml/h~2200.00ml/h
Step: 0.01ml/h Step: 0.01ml/h;
30ml 0.10ml/h~1200.00ml/h Preset range 0.10~9999.99ml; Step: 0.01ml
Bolus setting range: Screen brightness 1 to 10
5ml 0.10ml/h~100.00ml/h Volume 1 to 10
Step: 0.01ml/h; Protection IP23
10ml 0.10ml/h~300.00ml/h Log reviews and trend
Step: 0.01ml/h; charts Available
20ml 0.10ml/h~600.00ml/h Anti-Bolus Available
Step: 0.01ml/h; Exhaust bubble
30ml 0.10ml/h~1200.00ml/h function Available
Step: 0.01ml/h; Nurse call Available
50/60ml 0.10ml/h~2200.00ml/h DPS Available
Step: 0.01ml/h; Buttons backlight Available
Accuracy (according to injection rate): Self-test Available
≤1.00ml/h ≤±5% Power off data storage
1.00~2200.00ml/h ≤±2% Available
Mechanical precision ≤±1% (The percentage error FTP, TCP function Available
between the specified motion Alarm:
distance and the actual Alarm level: 1 to 10
motion distance in the full Alarm volume: Max: 65db (The remaining 1
stroke of the syringe pump) ml)
Feature: Min: 45db (The remaining 1
Channel Two-channel ml)
Preset range 0.10~9999.99ml; Step: 0.01ml Blocking alarm: Range: 150~1000mmHg;
Useable syringes: Selectable within range Accuracy: ±20% or
KVO ±100mmHg,
(keep vein open): 0.10~5.00ml/h; (KVO will last whichever is greater
for 30 minutes, then alarm) default setting: 600 mmHg
Step:0.01ml/h Unit: mmHg, kPa, bar, psi
Injection volume Blocking alarm, no-operation
display range: 0.00~9999.99ml; Step: 0.01ml alarm, Will Complete alarm, emptying
Medicine volume alarm, completion alarm, syringe off
setting range 0.10~9999.99ml; Step: 0.01ml alarm, push rod error alarm, battery
Maximum injection low alarm, system error alarm, power
volume under a single line off alarm, battery exhausted
fault: 0.1ml Alarm, main motor speed abnormal
Drug type 2100 alarm, main motor direction abnormal
Syringe records 2000 sets alarm, main motor from drive
Night mode Volume and screen brightness detection direction abnormal alarm,
automatically adjust main motor slave drive detection
Bolus Manual and automatic speed abnormal alarm, slave drive 24V
Software Update Via USB port power supply abnormal alarm, slave
No operating time 0~5min(step:1min) drive communication abnormal alarm,
Lock Screen Manual and automatic KVO complete, board Communication
Bed number 0~999 error, battery not connected

*Notice: Specifications subject to changes without prior


notice. All rights reserved by Comen