0% found this document useful (0 votes)
28 views114 pages

Touchwin TG Manual

The document provides a comprehensive manual for the TP series touch screen, detailing hardware specifications, installation instructions, and software functionalities. It emphasizes the advantages of using a Human Machine Interface (HMI) for improved operational efficiency and ease of use in industrial settings. Additionally, it includes safety precautions and guidelines for connecting the device to programmable logic controllers (PLCs).

Uploaded by

MiguelAlvarez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views114 pages

Touchwin TG Manual

The document provides a comprehensive manual for the TP series touch screen, detailing hardware specifications, installation instructions, and software functionalities. It emphasizes the advantages of using a Human Machine Interface (HMI) for improved operational efficiency and ease of use in industrial settings. Additionally, it includes safety precautions and guidelines for connecting the device to programmable logic controllers (PLCs).

Uploaded by

MiguelAlvarez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 114

Human Machine Interface

PREFACE
TP SERIES TABLE OF CONTENTS
TOUCH SCREEN

HARDWARE PARTS
1 SUMMARY OF THE PRODUCTS
2 EXTERIOR SIZE
3 INSTRUCTIONS OF INSTALLATION

OPERATE SOFTWARE PARTS


MANUAL 1 ABOUT GRAPHICS SOFTWARE
2 INSTRUCTIONS YOU SHOULD KNOW
3 COMPONENTS
4 SYSTEM PARAMETERS
5 SAVE AND DOWNLOAD

APPLICATION PARTS
WAYS FOR TP SERIES OPERATION

APPENDIX
1 WAYS TO CONNENT WITH PLC

THE FIRST EDITION

113
TouchWin 使用手册

● ITEMS YOU MUST NOTE TO KEEP SAFE ●

Please read the relative manual carefully and pay attention when
design the system. Moreover, please note the following points in order to
operate the device correctly.

◎ ITEMS YOU MUST NOTE IN PRACTICE ◎

CAUTION

● When practicing, please follow you instructor or the instructions 。


● Please don’t refit parts of the machine at your will or change the layout。Or else
there will be some trouble、wrong actions、losses、even fire。
● When the practice machine gives off special smell or noise,please cut off the
power。

HAZARDOUS

● Please don’t touch the interface point,or you will get electric shock。
● Please not open the hood。

2
TouchWin 使用手册

PREFACE
PLC is usually called programmable logical controller (hereinafter
refer to as “this product”), It is a generally used industry
automatic control device which based on microprocessor, and multiply
computer technology, auto control technology and communication
technology. As the product has the advantages of small volume, large
capacity, simple to program, easy to maintain etc, especially, with
the ability to adapt bad industry environments and good performance,
its usage is more and more wide .so, it has been called one of the three
backbones (PLC,robot and CAD/CAM)in today’s industry.
The human machine interface (HMI) is the bridge of
intercommunication for the operator and the machine .The user can
combine the characters, buttons, graphics data freely to process or
monitor and manage the multi-function display screen on which the
information could be different at any moment. With the fast development
of mechanic device ,the operate interface before need to be
operated by skilled operator ,and it is hard to operate. So, it is
impossible to improve the work efficiency. But the HMI can clearly
identify and tell the operator the device’s present state, which make
the operation easy and lively and also reduce the mistakes made in the
operation. Even the new operator can operate the machine easily. Using
the HMI can also make the machine’s layout standardized, simplified
and decrease the I/O points needed by PLC monitor. This will reduce
the production cost, At the same time, with the panel control
miniaturized and high-powered, it promote the whole equipment’s
additional value relatively.

3
TouchWin 使用手册

TABLE OF CONTENTS
PREFACE................................................................................................................................. 3
TABLE OF CONTENTS ......................................................................................................... 4
HARDWARE PARTS .............................................................................................................. 6
1 SUMMARY OF THE PRUDUCTS ...................................................................................................... 6
1-1 FUNCTIONS ............................................................................................................................ 7
1-2 General Size ................................................................................................................................... 8
1-3 Each parts name ........................................................................................................................... 10
2-1 TP460-Lsize ................................................................................................................................. 14
2-2 TP560-L/TP560-T size................................................................................................................. 14
2-3 TPA60-L/TPA60-T size................................................................................................................ 15
3 FIX MEASURES ...................................................................................................................................... 16
SOFTWARE PARTS.............................................................................................................. 17
1 ABOUT GRAPHICS SOFTWARE ............................................................................................................... 17
1-1 Installation of the software........................................................................................................... 17
1-2 The components of software screen ............................................................................................. 18
2 INSTRUCTIONS YOU HAVE TO KNOW..................................................................................................... 22
2-1 New .............................................................................................................................................. 22
2-1-1 Creating new screens or windows......................................................................................... 24
2-2 Title setting for a screen or a window .......................................................................................... 26
2-3 How to make a graph ................................................................................................................... 29
2-3-1 Draw a line, a rectangle or a circuit/oval .............................................................................. 29
2-3-2 Draw a polygon, a fold line................................................................................................... 30
2-3-3 Draw an arc........................................................................................................................... 30
2-3-4 Change the size ..................................................................................................................... 30
2-3-5 Move of the selected objected............................................................................................... 31
2-3-6 Cut , copy and paste of the selected object ........................................................................... 32
2-3-7 Public unit and private unit ................................................................................................ 33
3 COMPONENTS ................................................................................................................................. 35
3-1 Text setting ................................................................................................................................ 35
3-2 Dynamic text ............................................................................................................................. 37
3-3 Lamp ......................................................................................................................................... 39
3-4 Bit switch .................................................................................................................................. 41
3-5 Lamp button .............................................................................................................................. 43
3-6 Image conversion ...................................................................................................................... 45
3-7 Data display............................................................................................................................... 46
3-8 Alarm data display .................................................................................................................... 48
3-9 Text display ............................................................................................................................... 49
3-10 Data input ................................................................................................................................ 49
3-11 Text input................................................................................................................................. 50
3-12 Chinese input........................................................................................................................... 51
3-13 Digital keyboard...................................................................................................................... 52
3-14 ASCⅡ keyboard .................................................................................................................... 53
3-15 Data setting.............................................................................................................................. 53
3-16 User input ................................................................................................................................ 54
3-17 Transfer the window................................................................................................................ 55
3-18 Vertical bar .............................................................................................................................. 56
3-19 Horizon bar............................................................................................................................ 58

4
TouchWin 使用手册

3-20 Dynamic image ..................................................................................................................... 60


3-21 Window button ........................................................................................................................ 62
3-22 Function button ....................................................................................................................... 63
3-23 Function field ........................................................................................................................ 65
3-24 Real time graph ....................................................................................................................... 67
3-25 Scatter column graph............................................................................................................. 70
3-26 Continue column graph ......................................................................................................... 71
3-27 Data collect and save.................................................................................................................. 73
3-28Profile table ................................................................................................................................. 75
4 ALARM WINDOW ............................................................................................................................. 78
5 PRINT WINDOW ............................................................................................................................... 80
5-1 Create a new print window........................................................................................................... 80
5-2 Connection of the printer.............................................................................................................. 81
6 SYSTEM PARAMETER ............................................................................................................................ 82
6-1 System setting .............................................................................................................................. 82
6-1-1 Start up the screen and set up the background ...................................................................... 82
6-1-2 Order setting ......................................................................................................................... 82
6-1-3 Screen protecting .................................................................................................................. 82
6-2 Control in turn .............................................................................................................................. 83
6-3 PLC type choosing ....................................................................................................................... 83
7 SAVE AND DOWNLOAD ......................................................................................................................... 84
7-1 Save the project ............................................................................................................................ 84
7-2 Download ..................................................................................................................................... 84
8 SPECIAL FUNCTIONS ............................................................................................................................. 86
APPLICATION ...................................................................................................................... 92
1 TP SERIES OPERATE METHODS ............................................................................................................. 92
1-1 TP series online communication .................................................................................................. 92
1-2 TP series touch screen orders ....................................................................................................... 92
APPENDIX ............................................................................................................................ 95
1 PLC CONNECTION METHODS.................................................................................................... 95
1-1 Xinje FC series............................................................................................................................. 95
1-2 mitsubishi FX series..................................................................................................................... 97
1-3 SIEMENS S7-200 series ............................................................................................................ 100
1-4 OMROM C series ...................................................................................................................... 101
1-5 Koyo S series.............................................................................................................................. 103
1-6 Delta DVP series ..................................................................................................................... 106
1-7 LG Master-k series PLC............................................................................................................. 108
1-8 Panasonic FP series PLC......................................................................................................... 110
1-9 Schneider Electric PLC .............................................................................................................. 114

5
TouchWin 使用手册

HARDWARE PARTS

1 SUMMARY OF THE PRUDUCTS

TP series touch screen is a new break to replace control panel and keyboard, It is a new feature of the
machine. With direct image, good compatibility, high performance-price ratio, they have been the first choice
of middle size and small size control.

According to product’s sizes, operation ways, there are models in the following table:

Display sizes Display materials TP series

4.7 Inch Black-white LCD TP-460-L

Black-white LCD TP-560-L


5.7 Inch
256 color TP-560-T

Black-white LCD TP-A60-L


10.4Inch
256 color TP-A60-T

If there are no special explain, all the models’ working voltage in the above table is DC24V.

The components of the product model

Example of the model name:

TP-5 6 0-L
L: means monochrome; T: means
l
60: means 60 series

5: means 5.7 inch; 4: means 4.7


inch
A: means 10.4 inch
\
TP: means touch screen

6
TouchWin 使用手册

1-1 FUNCTIONS

TP series touch screen is a mirror inside the machine. It can tell all the things of the machine’s action in
time, lively and correctly by displaying with images, lamps etc. Besides, it has special performances on
parameter setting, displaying, warning and memory.

Advantages Comparing to the console and simulate instruments, it has the advantages as
following:

1) Small volume, beautiful exterior, impropriate nearly no space


2) Easy to connect
3) All kinds of display are lively
4) It can memory lots of data
5) With strong function, it can read and write PLC data at your will
6) Large amount of image facture

Main function Monitor: Tell PLC’s inside state, memory data with data, fold-line, image,
dynamic image etc. So it can tell the industry control system’s flow and trend
directly.
Control: You can change PLC’s inside state bit, memory data via touch screen.
In this way you can participate in process control.
Data disposal: Real time sampling and information disposal, it can even
connected to factory’s local area net to realize data share and machine’s
long-distance control

7
TouchWin 使用手册

1-2 General Size

1、 Electric Size

Model TP-A60-T TP-A60-L TP560-T TP560-L TP460-L

Input voltage DC20-DC28V

Consume current 380mA 380mA ﹤220mA ﹤200mA ﹤180mA


Instantaneous
Less than 20ms
power cut allow

- Endure voltage AC1000V-10MA one minute(signal and time)


Insulated
DC500V-about 10MΩ(signal and time )
resistance
Communication
Support RS232/RS422/RS485
port

2、 Environment conditions

Model TP-A60-T TP-A60-L TP560-T TP560-L TP460-L

Operate temperature 0-50℃ 0-60℃

Store temperature -20-60℃

Environment humidity 20-85%(no coagulate dew)

Endure vibration 10-25HZ(X,Y,Z direction each 30 minutes 2G)

Resist interfere Voltage noise:1000Vp-p、pulse width 1us、one minute

Surrounding atmosphere No canker gas

Protect configuration Accord with IP65

8
TouchWin 使用手册

3、 Image attribute

Model TP-A60-T TP-A60-L TP-560-T TP-560-L TP-460-L


TFT 4 rank gray TFT CCFL
Type monochrome
Color LCD color Color LCD monochrome
Use life 50000 hours upwards,environment temperature 25 degrees,24 hours run
Display area 800*600 640*480 320*240 240*128
lightness Potentiostat can adjust
Word setting Brief Chinese;English
Text size Random size,random style
Touch panel Matrix type touch Matrix type touch Matrix type touch
screen 8MB 4MB 2MB
data 4MB 2KB 1KB

4、
Configuration size

Model TP-A60-T TP-A60-L TP-560-T TP-560-L TP-460-L


Cooling
Natural wind cooling
manner
Exterior 173.2*121.4
311*234*48 189.4*141.4*44.4
Configuration size *45
Panel
opening 301*224 181*133 164*112
hole size

9
TouchWin 使用手册

1-3 Each parts name

TP460-L touch screen:

Front image

Touch
area

Inverse image

Power Download Communication


outlet port port

10
TouchWin 使用手册

5.7 inch touch screen:

Front image

Inverse image

Communication
port

Download
port

Power end

11
TouchWin 使用手册

TP-A60-T/TP-A60-Ltouch screen:

Touch
area

*-
Inverse image

Power Download Communication USB1 USB2


outlet port port

12
TouchWin 使用手册

1-4 Interface definition and download cable


TP touch screen series port communication feet define number:

Feet definition Feet definition


number mark
1 TD+ 1 NC
2 RXD1 2 RXD2
3 TXD1 3 TXD2
4 A1 4 A2
5 GND 5 GND
6 TD- 6 BUSY
7 B1 7 B2
8 RDD- 8 NC
9 RDD+ 9 NC

TP communication port TP download port

TP touch screen download cable connection map:

Feet Feet
mark definition mark definition
1 NC 1
2 RXD2 2 RXD
3 TXD2 3 TXD
4 A2 4
5 GND 5 GND
6 BUSY 6
7 B2 7 RTS
8 NC 8
9 NC 9

TP download port Computer COM port

reference:On the base of hereinbefore download cable,meet the eighth foot and fifth foot in short, then
you can download TP with force.

13
TouchWin 使用手册

2 Exterior size
2-1 TP460-Lsize

TP460-L real size (unit mm) :163.2×111.4×45

fix hole size (unit mm) :165×113

2-2 TP560-L/TP560-T size

TP560-L real size(unit mm):180.4×132×44

fix hole size(unit mm):182.4×134.4

14
TouchWin 使用手册

2-3 TPA60-L/TPA60-T size

TPA60-L/TPA60-T real size(unit mm):311×234×48

fix hole size(unit mm):301×224

15
TouchWin 使用手册

3 fix measures

When you buy a TP, there will be 4 iron install frames with it. There are two square fix holes on the
display’s upside and downside. Use the frame to fix the display tightly in the control tank’s install holes.

Touch screen’s temperature will go high if it works too long. So, you’d better hold 10 cm space for the
touch screen to avid this (each side 5 cm). Then the atmosphere will change freely.

Install steps 1. Refer to hereinbefore graph’s size. Open a


square hole on the control tank’s panel.
2. Add airproof circles in the airproof trough when
installing
3. Plug the display’s bottom to the hole of control
tank
4. Set the install frame into the display’s side fix
hole and screw the screw
5. Connect the display and PLC communication
port with cables. The communication cable can
be offered by the supplier or make by yourself,
give +24V direct power to start working

16
TouchWin 使用手册

Software parts

1 About graphics software

This chapter describes TP series touch screen software’s project screen and its components , and the
components of toolbox ,template in addition .

1-1 Installation of the software

Find “setup.exe” in the touch screen software and double-click it

Click “next” or “yes” all along to enter user information dialog box

Input user name、company name and serial number。


The serial number is:11111111111111 or Xinje TouchWin(note if the letter is in
capital or not and the blank),
Then click “next”。

17
TouchWin 使用手册

Click “next” all along until finish installation and then click “finish”。

If the installation is finished ,there


will be an icon on the table as
following。

1-2 The components of software screen

TP touch screen’s interface display contents are the following image,each name and function is described
as follows:

18
TouchWin 使用手册

Graphic toolbox

Name of each tool ⑴Draw a line ⑵Draw an arc


button
⑶Draw a rectangle ⑷Draw a circuit or an oval

⑸Draw a polygon or a multi-segment line ⑹Frame

⑺Map (8)Select unit

Parts toolbox

Name of each
tool button (1)text (2)dynamic text

(3) Variational text (4)lamp

(5)bit operate button

(6)lamp button (7)screen jump

(8)digital display (9)alarm display

(10)text display (11)data input

(12)text input (13)Chinese input

(14)set data (15)digital keyboard

(16)ASCⅡ keyboard (17)user input

(18)vertical bar (19)horizon bar

(20)dynamic image (21)call window

(22)window button (23)down scheme

(24)up scheme (25)function button

(26)real trend map

(27)scatter column map (28)continue column map

19
TouchWin 使用手册

Display toolbox

Name of each
tool button ⑴date ⑵clock

⑶buzzer ⑷LCD light control

⑸valve ⑹pipe

⑺pump (8)auto wind

(9)convertor alarm information

(10)real time map (11)history data map

(12)event button (13) display real time event

(14)display history event (15)sample save

Operate toolbox

Name of each
tool button (1)public unit (2)private unit

(3)new (4)property

(5)delete (6)download

Zoom toolbox

⑴ ⑵ ⑶ ⑷

Name of each
tool button ⑴zoom out ⑵zoom ratio

⑶zoom in ⑷menu gridding

20
TouchWin 使用手册

Standard toolbox

Name of each ⑴new ⑵open


tool button
⑶save ⑷cut

⑸copy ⑹paste

⑺about

Graph adjust
toolbox

(1)align left (2)align center


Name of each (3)align right (4)align top
tool button (5)align middle (6)align bottom

21
TouchWin 使用手册

2 Instructions you have to know

Before you use the program software , you should make sure which model the touch screen is and what
kind the PLC is, all these are the precondition to decide whether the software could download in gear and
communication .

2-1 New

1 Click “new” icon in the standard tool column .

“new” icon

2 When you set up a new project, there will come out a dialog box as the following left map, you could
choose the touch screen’s model , and then click “next” .

3 In the upward map you could choose the PLC’s type, click “setting” to enter communicate parameter
setting dialog box.

22
TouchWin 使用手册

4 When the touch screen communicate with different kinds of PLC, the communicate parameter will be
different .The default value is auto set when you choose the PLC model. If there is no special change, please
don’t change it at your will to avoid communication mistakes. If you finish setting, click “OK” and there will
pop out a new project.

23
TouchWin 使用手册

2-1-1 Creating new screens or windows

2-1-1-1 Creating new screens

1:There are two ways to create a new screen:

A:①Click “screen” in the project manage area with the mouse’s left key to make it the opposite color;
②Click “new” in the operate toolbox。(the detail operation is as the following map)

B: Insert a new screen in the console 。(the detail operation is as the following map)

Click “screen” with the mouse’s left key in the project manage area to make it the opposite color, then
click the mouse’s right key , click “insert” in the pop menu .

24
TouchWin 使用手册

2 There will pop out a new screen dialog box. Input screen’s ID and screen name , finally click “OK” and
you will finish creating a new screen .

2-1-1-2 Creating new windows

1 There are also two ways in creating windows:

A:①Click “window” with your left key in the manage toolbox to make it opposite color②Click “new” in
the operate toolbox

25
TouchWin 使用手册

B: Insert a window in the console(the detail operation is as the following map)

Click “window” in the project manage area with the mouse’s left key to make it the opposite color,Click
your right key , in the pop out menu just choose “Insert”

2 There will pop out a new window dialog box, set the window ID and its name, size. Finally click “OK”
and you will finish creating a new window.

2-2 Title setting for a screen or a window


1 When creating a project screen (window), We often give each screen (window) a different name to
identify the screen (window).There are two ways to modify their name.

WAY 1

Click a certain “screen” or “window” in the console with the mouse’s right key, then choose “property” in
the pull down menu

26
TouchWin 使用手册

WAY 2

Click in the operate toolbox directly

27
TouchWin 使用手册

2 A setting map will pop out(as the following map)

3 Input the user-name in the “name” bar

If you click the window property, you can also set its size in the pop out dialog box

28
TouchWin 使用手册

2-3 How to make a graph

Graphics toolbox

2-3-1 Draw a line, a rectangle or a circuit/oval

The following describes how to draw a line, a rectangle or a circuit/oval

Here we take drawing a line as an example

1 Click in the graphics bar。


Draw a rectangle :click ;
Draw a circuit/oval:click 。
2 Click your left key at the start dot
3 Drag the cursor to the end dot
4 Let the mouse’s left key go to finish drawing a line
5 Set the property

Procedure of setting the property


I If the object is in the state of been
selected, double click the mouse’s left key
or click in the operate toolbox, then
there will pop out a property dialog box

Choose of the line’s thickness(input value is an integer


between 0~255)。

Ⅱ There are two options for the line’s color


(At present the touch screen is monochrome,
so, “more” button is useless)

29
TouchWin 使用手册

III Input the start position in the position area , in the


size area , width stands for the horizontal length and
height stands for vertical length

IV When you choose lock , the line’s position is


fixed in the screen and couldn’t carry out any
operation .(except for property choose and delete)。
V Click “OK” to save your setting when you finish it

2-3-2 Draw a polygon, a fold line

The following describes how to draw a polygon, a fold line

Here we will take drawing a polygon as an example

1. Click in the toolbox


2. At the start dot of the polygon, press down your left key
3. Drag the cursor to the second acme’s position
4. Let the left key go to fix the second acme’s position
5. If you increase the acme number, please repeat doing this
6. Double click at the end acme and you will finish drawing
a polygon
7. The property setting(the same as before)

When setting property ,you may refer to line’s property setting

2-3-3 Draw an arc

The following describes how to draw an arc

1. Click in the toolbox


2. At the start dot of the arc, press down
your left key
3. Drag the cursor to the end, then let it
go
4. Property setting

2-3-4 Change the size

The following describes how to change the graph and the object’s size

Graph and object’s size show how to extend or shrink

30
TouchWin 使用手册

WAY 1:

I Choose one that you want to extend or shrink

II On the ,press your mouse and drag when it becomes 。

III Let the mouse’s left key go to finish changing the size.

WAY 2:
Choose “position” in the property dialog box,
input the object’s horizontal width and vertical
height in the “width” and “height”, then click “OK”.

2-3-5 Move of the selected objected

The following describes how to move the maps and the objects

WAY 1:

I Choose the map or object you want to move

31
TouchWin 使用手册

II Move the cursor to the map, object, the cursor will become

III Press your left key and drag it the place you want

IV Let the key go to fix the position

WAY 2:
Choose “position” in the property dialog box,
choose the coordinates you want(the coordinates’
norm is in the up-left)。

2-3-6 Cut , copy and paste of the selected object

The following describes how to cut ,copy and paste a graphics or an object

1. Choose one that needs to be cut


2. Click the toolbox:cut ,copy 。
3. Click in the toolbox

● When choosing one that needs to be cut ,


copy or paste ,the following key will realize
the same operation

cut:Ctrl+X

copy:Ctrl+C

paste:Ctrl+V

32
TouchWin 使用手册

2-3-7 Public unit and private unit


In order to improve work efficiency, we offer public unit and private unit operation. Public unit can make
the current screen’s one or more units be used by all the screens;private unit is the opposite of public unit, it
can only be used by the current screen.

For example:
We create 3 screens in all。In the first
screen ,we add a rectangle(other units and
components can be used ,too)and choose it,
just as the following map。

Then we click the public unit button


,we will find in the second and third
screen’s same place, it auto adds a
rectangle。

If we only want to keep the rectangle in the


third screen, we will use private unit. Choose the
rectangle in the third screen。

33
TouchWin 使用手册

Then click private unit button ,we will find


that only screen 3 has a rectangle. The rectangle
will disappear in screen 2 and screen 1.

34
TouchWin 使用手册

3 COMPONENTS

Components
toolbox

3-1 Text setting

1. Click “ ”icon in the components toolbox


2. Drag cursor into the screen , click the mouse’s left key to place the text(click the right key or press
the ESC key to cancel your place)。

3. Double click the left key or choose icon , there will pop out a text setting dialog box.

I Display the setting:


①This contains content , frame and align mode

35
TouchWin 使用手册

②Click , There will come out a


“file select” map , you can choose text frame here

II Font choose

①We offer different font in TP series touch screen ,


choose in the font

②There will come out a font setting dialog box

4 click ,and you will finish setting the text

36
TouchWin 使用手册

3-2 Dynamic text


In the industry control process, the machine’s state may be more. By these dynamic text the machine can
display these different states. This make the operator much convenient and improve the work efficiency. So
dynamic text is your ideal choice.

1. Click “ ”icon in the components toolbox


2. Move cursor into the screen, click your left key to place it in the screen area(click your right
key or press ESC key, to cancel place)。

3. When the text is been selected, you could choose property.

I Choose the dynamic text’s object type.

PLC Register’s define ID correspond to


the display

Different model of PLC, its object and area are different. You may refer to appendix to know
more

37
TouchWin 使用手册

II Each register correspond to 16 states , each part’s


corresponding value is 0~15, when the register value is 0,
the dynamic text will display the content of text 0.Others
are the same. You can also choose align type and text
frame.

III Choose of font and size

IV Choose of text’s position and size


V Click “OK” and you will finish property
operation

38
TouchWin 使用手册

3-3 Lamp
In the operation process, in order to display clearly what operation is been take or what state is the
machine, we offer fast way for the operation and monitor.

1. Click “ ”icon in the components toolbox


2. Move cursor into the screen, click your left key to finish placing the lamp(Click your right key
or press ESC key to cancel placing)。

3. Click property and there will come out a lamp dialog box。

Ⅰ Set station number to “1”。

Ⅱ Object type setting


PLC relay bound correspond to the
display

39
TouchWin 使用手册

Ⅲ Lamp map choosing。

You could choose the relay ON or OFF map

Ⅳ Click to change the lamp


map

40
TouchWin 使用手册

3-4 Bit switch

1. Click icon
2. Move cursor into the screen, click your left key to finish placing bit switch button (click your
right key or press ESC to cancel placing)
3. Click property and there will pop out bit switch button dialog box

I Choose bit switch button in the object


type

II There are four states for bit switch button, at


the same time you could choose key-press content
and align mode

Ⅲ Press “OK” to finish property setting

SET ON

When the button is pressed down ,the selected middle relay will be set ON。

SET OFF

When the button is pressed down ,the selected middle relay will be set
OFF。

41
TouchWin 使用手册

REVERSE

When the button is pressed down, the selected middle relay will be set the
opposite logic

MOMENTARY

When the button is pressed down ,the selected middle relay will be set
ON ;when the button gets up ,the selected middle relay will be set OFF。

42
TouchWin 使用手册

3-5 Lamp button

The lamp button has the function of lamp and button, but the lamp and the button could also be used
separately for different relays.

1 Place the lamp button in the screen。

2 Lamp button property setting(when not choosing the monitor object, the lamp button will be only used as
button)。

Operate object

It shows that the lamp button has the key-press function to some middle
relay

43
TouchWin 使用手册

Watch object

It shows that the lamp button display some middle relay’s state (ON or
OFF)

3 Operate setting

Button operation

There are four states for the button operation

Map

As a button , it has two states:“button on”、“button off”

As a lamp , it has two states:“state ON”、“state OFF”

Change the graph of the lamp button

Press“Changing”,in the pop out “file select” dialog box, you could choose
your map and click to finish .

44
TouchWin 使用手册

【NOTE】Operate object and watch object couldn’t set the same。

3-6 Image conversion

Image conversion is used to convert different images of the touch screen


Setting of image conversion:

4. 1 Click and place it in the screen(click your right key or press ESC to cancel placing)

45
TouchWin 使用手册

2 Set the property of image conversion

Image conversion

When trigger the image conversion button ,the image will convert to the
object image。

3-7 Data display


In the industry control process, the machine run parameter could tell if it is ok or not. So, it is display’s
another advantage to display the machine’s action in figure. This function is the contribution of data display.

1. Click icon
2. Move cursor into the screen to place it in the screen(click your right key or press ESC to cancel
placing)

46
TouchWin 使用手册

3. Click property and there will pop out a data display dialog box

I Choose object type(register type, ID


and if the data is single word or
double)。

II In the “display” you could set data type,


length ,align type and character’s frame, color
and position。

Bit length

Display or set the max number

Decimal fraction

Keep the efficient bits after the decimal。

Decimalization

Display the register’s data in the form of algorism(We suggest that


mitsubishi and OMRON’s PLC use this form)

Float number

Display the register’s data in the form of float

47
TouchWin 使用手册

Unsigned number

The highest bit of register is 1,it is not a sign bit. For example:FFFF means
65535。

Hex /BCD

Display the data in the form of hex/BCD。

3-8 Alarm data display

In order to protect the operation, some data must have certain restrict. Data alarm display will glitter when
the data exceed the restriction .This will awoke the operator to take action。

1. Click icon in the components toolbox


2. Move cursor into the screen , place it in the screen(click your right key or press ESC to cancel
placing)
3. Click property,there will pop out alarm display dialog box。

I You could refer to data display on setting


of object and display type

II According to practice demand, you could


set the max value and min value .If the data goes
beyond the bound, the data and the frame will
glitter at the same time.

III You could refer to dynamic text in


displaying font, color and position.

IV Click “OK” to finish。

4. When the data goes beyond the bound of alarm display, the alarm data will continue to glitter, this
awoke the operator。

48
TouchWin 使用手册

3-9 Text display

Text display is used to display the register data in the form of text in the touch screen.

You could refer to data display for detail。

3-10 Data input

Data input is used to modify every parameter which is run by the machine freely by touch screen .It is
another way for human machine connection.

But when inputting data there must be a digital keyboard .So data input must be used with keyboard.

The following is the data input steps:

1 First, place “data input” component in the screen, if the modify data is more, you could put more data
input components as the following:

You could refer to “data display” setting in


setting data input。

2 Click “data input” component to make it the opposite color .(If the data has a protect password,
you should input the password before modifying the data)。

3 When the data input frame turns to the opposite color, there will come out a small digital keyboard
as the following:

49
TouchWin 使用手册

3 After input the number press“ENT”on the keyboard to finish data input .The small keyboard will
disappear at the same time.

4 When data input is more, just repeat step 1~3。

3-11 Text input


Just like data input, when input text there must be a small text keyboard, too.
The following tells the text input steps:

1 First, place text input component in the screen , if the modify text is more ,you could put more text input
components as the following:

You could refer to text display setting


in setting of text input。

2 Click text input component to make it in the opposite color .(If the text has a protect password,
you should input the password before modifying the text)。

3 When the text input frame turns to the opposite color, there will pop out a small text keyboard as
the following:

50
TouchWin 使用手册

4 After input the text, press“ENT”on the keyboard to finish text input .The small keyboard will
disappear at the same time.

5 When data input is more, just repeat step 1~4。

3-12 Chinese input


“Chinese input” is used to input Chinese into register unit by touch screen. When inputting Chinese a
small keyboard and a character spell window is needed.
The following tells the character input steps:
1 First, place “Chinese input” component in the screen, if the modify Chinese is more, you could put
more Chinese input components as the following:

2 . Click text input component to make it the opposite color .(If the text has a protect password, you
should input the password before modifying the text)。

3 When the Chinese input frame turns to the opposite color, there will come out a small text keyboard
as the following:

51
TouchWin 使用手册

Chinese search upward


or downward

Chinese input
cushion area
Area to choose
Chinese

Input the
spelling

4 First, spell the character you want and input them on the keyboard. In the Chinese choosen area it will
display five homophone. You can press “up” or “down” button to find the character. After choosing it,
press “ENT” to finish. The keyboard will disappear at the same time. When you want to modify, just
press “<-”。
5 When Chinese input is more ,just repeat step 1~4。

3-13 Digital keyboard

1. In the process of input and modify the data, keyboard plays an important role to link people and
machine. As it is simple and convenient, the current operator is more likely to use it.
2. You can refer to others to place the small digital keyboard.
3. Small digital keyboard must be used with data input.

In the “data input” we have introduced before, we adopt the keyboard’s use mode as the default state,
this is pop out mode. But we can modify data input and character input property at the same time. Such
as the following map:

In the input choice of data input property setting,


throw off the tick in the “pop keyboard”, then the
keyboard will not pop out any more. So we need to add a
digital keyboard or a text keyboard in the screen when
we add data input components or text input components.

52
TouchWin 使用手册

3-14 ASCⅡ keyboard


Just similar to digital keyboard , ASCⅡ keyboard must be used with text input .You could refer to digital
keyboard.

3-15 Data setting

1. Click icon
2. Move cursor into the screen. Click the left key to finish placing data setting button (click your right key or
press ESC button to cancel placing)
3. Click property and there will come out data setting dialog box.

I Choose register’s type and ID in the


object. Choose data type at the same time.

II In the operate option, if you choose arithmetic,


that means do arithmetic with the data in the set
register. The example in the map is that after the
operation add 10 to the register’s data.

53
TouchWin 使用手册

Ⅲ If you choose set constant, it means give a


value to a correspond register. In the following
example, it shows that after the operation, the
correspond register will be evaluated 10. The former
value in the register will be covered.

Press “OK” to finish.

3-16 User input

User input key is the base to compose each figure input key in the small keyboard. You can input letters at
the same time. But the letters are inputted in the format of ASC.

You can refer to upwards setting for the other settings.

54
TouchWin 使用手册

3-17 Transfer the window

The following describes the way to transfer the window.

I Create a new window to be transferred .Set


the window’s size, name and other
information .

II Click in the components toolbox,then


place it in the screen。

III Click property button. Set the relay’s type and


address in the object. When the middle relay is in
the state of ON, the window to be transferred will
pop out. When it is OFF, the window will be close.

55
TouchWin 使用手册

IV Set the window’s ID.

V Set the window’s position.

【NOTE】:Transfer the small key is the same to transfer the window. Just put the small keyboard in the
transferred window.

3-18 Vertical bar

Bar graphics is another format to display data.


Vertical bar graph is used to vertical display analog parameters such as temperature, pressure, flux and so
on . It displays data in the form of percent based on the max value and min value set in the property .The
height and width could be set at your will.

1 Click ,drag cursor into the screen , then click your left key just as the following .

2 Double click the bar graphics or click property, there will come out a property dialog box.

56
TouchWin 使用手册

Object type
Register’s ID in the PLC.

Direction

Direction when the bar increase.

Format

The type when the bar changing.

Max and min

The max value and min value that the bar map shows

Color

You can set the bar map’s bar color and frame color .

57
TouchWin 使用手册

Position

You can set the position in the screen.

3-19 Horizon bar

1 Click ,drag cursor into the screen , then click your left key just as the following .

2 Double click the bar graphics or click property, there will come out a property dialog box .

Object type
Register’s ID in the PLC.

58
TouchWin 使用手册

Direction

Direction when the bar increase .

Format

The type when the bar changing .

Max and min

The max value and min value that the bar graphics show

Color

You can set the bar graphics ‘s bar color and frame color .

Position

You can set the position in the screen .

59
TouchWin 使用手册

3-20 Dynamic image

Setting dynamic image is the same as dynamic text. If the register’s value is different, they will all display
different text (or image). The register value range from 0 to 15 (16 states). As the register value (0-15) different,
it will display different image.

1 Click , place it in the screen 。

2 Set dynamic image’s property 。

Station number

We default Station number 1。

Object type

Register’s ID of PLC 。

60
TouchWin 使用手册

3 Set dynamic map

Map 0~map15

In the “object”, register’s value 0-15 correspond map 0—map 15 。

Changing

User’s self-defined map

4 Click ,there will come out a dialog box ,you could choose your map 。

NOTE:map format must be *bmp format 。

61
TouchWin 使用手册

3-21 Window button


We have introduced transferring the window before. But in the process of transferring the window, we
may discover that we need a relay. This is so trivial, and when we open the window, we couldn’t close it in the
current window . Window button will solve all these problems 。
The following ,we will tell you how to use the window button 。
ⅠCreate a new window 。

II Click button in the components


toolbox and place it in the screen 。

III open the property setting dialog box, click


“Operate” and fill the window’s ID which you want to
operate. If you want to operate the current window, just
choose “current window”. Then, the window ID color
will turn to gray .In the “Act” column, you could set act
mode :open, close, hold .You could also set the window
hide or show .

IV In the “display” column, we could modify the text


content which will display on the button .If you want to
close a window by this button ,you can change it to
“close” .
Click “OK” to finish setting the button 。

62
TouchWin 使用手册

3-22 Function button


Function button gathers the function of all buttons .It can choose function for the button, this can make the
button carry out different function.

1. Place in the screen 。

2. Double click the function button or click property, there will pop out a dialog box.

63
TouchWin 使用手册

Function
The function button has four types. they each stands for four states : released ,pressed ,releasing ,pressing .
We could add different function for the four states at one time.

Option
It shows that the button’s certain state can add the following function operation: set coil, reset coil, reverse
coil, copy coil , screen jump , set data , copy register ,user input ,open window , close window ,down
scheme ,p scheme ,data block transmit ,arithmetic .
After finish adding the function, you can carry out modify operation to obtain your user’s require.
Set coil
Set“1”to certain relay or bit
Reset coil
Set“0”to certain relay or bit
Reverse coil
Reverse certain relay or bit
Copy coil
Copy the source coil’s data to the aim coil
Screen jump
Make the screen jump to the appoint screen
Set data
Set the appoint value to the appoint object
Copy register
Copy the register’s value to the aim register
User input
Input button codes, the codes are in the form of ASC
Open window
Open the appoint window by the window ID
Close window
Close the appoint window by the window ID
Down scheme
Download the scheme data (touch screen) to the device data (PLC)
Up scheme
Upload the device data (PLC) to the scheme data.
Data block transmit
Transfer the appoint source ID register’s data to the correspond aim ID register
Arithmetic
Do an arithmetic with the set register’s data, then save the final value in the appoint register

64
TouchWin 使用手册

3. Property setting

Maps
There are two states as a button:“Pressed”、“Released”。
Changing
Press“Changing”,there will pop out a “File select” dialog box of the map .You could choose any map you
need.

3-23 Function field


Function field’s usage is similar to function button, but they are not the same. The difference is on the
function’s trigger action. Function button can set different operation to the four trigger action. But the function
field has only one trigger action, and must be touched off outside.

1. Place in the screen.

65
TouchWin 使用手册

2. Setting of function field property

Act mode (User can only choose one trigger action)


Start screen
When the screen in which is the function field is transferred, the function field’s ever has function will be
carried out.
Coil spring
When the appoint coil jump from 0 to1, the function field’s ever has function will be carried out.
Time (sec.)
When the screen in which is the function field is transferred, the function field’s ever has function will be
carried out. These function will be carried again in a certain time (can be set)
Continue
When the screen in which is the function field is transferred, carry out the ever has function in the function
field continually.

3. Option card

The option card’s function is the same to function button’s. Just add them in the function

66
TouchWin 使用手册

3-24 Real time graph


Real time graph can show the appoint register’s value change to the user directly in the form of graph. The
trend graph will sample the PLC register and display its state timely. When each sample cycle is over, new
data will be read and displayed in the right of the trend graph. The display has the property of real time.

1. Place in the screen.

2. Real time graph property setting

Add
You can add many appoint register, appoint many object.
Modify
Modify the trend graph property of the appoint object.

67
TouchWin 使用手册

3 press the “modify” button to enter the appoint trend map property.

In the object type we can find that there is an indirect appoint choice frame. This is a new function. In fact,
the indirect appoint is to add indirect appoint value’s ID to current ID (W0).
Choose indirect appoint choice frame, there are two choice card in the indirect appoint object. They are
object and data.
Set object as PSW270。Set data’s multiply ratio as 3。So, here our object is W(0+PSW270’s value *3)。

68
TouchWin 使用手册

4 Trend property setting。

Data
Count
Show the number real time graph can display。
Pick period
Show time space when real time graph pick data each time. It must be an integer.
Range
Show the range of real time graph’s vertical change. The user can pre-set.
Map mode
The graph’s display mode is fold, dot or column
Display mode

5 Save

Object type:appoint the original ID after data sample is over and need to save.

69
TouchWin 使用手册

As the data should save in the in the table, the first four bytes are used to save the table’s head
address and tail address. So, the data’s real address is the appoint object’s address plus 4. We default it as
PSW(256+4)

3-25 Scatter column graph


Scatter column graph’s horizon axis take scatter register as foldline object, and present each register’s
value with graph.

Place scatter column graph in the screen。

1. Set the scatter column graph’s property。

Display object table


Display each appoint register object, you can add, modify or delete the display object. The system default three
display objects.

70
TouchWin 使用手册

2. Set the display property。

Degree
Show the real time graph’s vertical change area, the user can pre-set
Format
In which form. does Scatter column graph change
Pattern
Scatter column graph’s display pattern, there are three choices: fold, dot, column

3-26 Continue column graph


Continue column graph’s horizontal axis take continue register as its object. Display each register’s value
in the form of graph.

1. Place continue column graph in the screen。

2. Set the continue column graph’s property.

71
TouchWin 使用手册

Choose object type(Register’s type, address and single word or double)


Display property setting.

Number
Show the number to display. The data address is from the appoint one. Here we default it 5.
Format
`In which format is the continue column graph change.
Pattern
Continue column graph’s display pattern: fold, dot or column.

72
TouchWin 使用手册

3-27 Data collect and save


“Data collect and save” can collect data in a certain cycle and save it in the register unit whose start ID has
appointed.

1 Place in the screen

2 Set data collect and save property.

Display object table


Display each register’s object, you can add, modify, delete, move up or move down the display object.
6 Collect setting

73
TouchWin 使用手册

a) Count
Total number of data to collect.
b) Period
Collect data in a certain time.
c) Manner
If collecting data and time is at the same time.

7 Save the settings

a) Object
The start address for the data when they are collected over.

74
TouchWin 使用手册

3-28Profile table
The profile table is used to display real time alarm notes and history alarm notes. It controls event’s
information and trigger time’s display with a bit. Meantime, history notes are saved in TP series touch screen’s
continue register inside. The start address and number can be set by the user freely.

Profile table divides into history event display and real time event display. is event
control button. The user can choose it to use freely. The difference is : history event display save the trigger
event in order in the user-appoint register, user can look them over and affirm or delete; real time event
display can only display the spring event real time, when the event triggers no more, the information will
keep no more, when there are many events trigger at the same time, display all of them.
The following, we will take history event as the example to describe:
1. Add in the screen, just as the following map:

2. Set the property


The appearance option card is the first:

75
TouchWin 使用手册

Column:You can separately adjust three column’s title, align mode and column width.
You can appoint row’s height and row number of each page.

If choose ,the event’s spring time will display as


FFFF year FF month FF day FF hour FF minute FF second.
Event capacity show the max number of history notes.
Event option card:

Click “add” button to add events. The serial number will in order.
Click “modify” button, modify the coil correspond to column,display
instead of appointed. For example: the serial number is 1:when M0 coil’s rise border
comes, it will promote “temperature high”.
Click “delete” button to delete the event chosen at present.
Save the option card:

76
TouchWin 使用手册

In the object type column choose the register’s type. Fix the address yourself.
NOTE:The first four word’s save information is the first address and end address of history event. The
real notes start from the set address plus 4.
The other option cards are: font, color and position etc. The user can refer to other control’s description.

3. Add button and set its relative property, just as the following:

Choose the correspond action in the key option. The following are the details:
Previous page The profile table display previous page’s history notes.
Next page The profile table display the next page’s notes.
Previous item Move to the up line from the current position.
Next item Move to the down line from the current position.
Clear Clear all the history notes in the profile table.
Affirm Affirm of the current position’s event.
4. The example is the following :

77
TouchWin 使用手册

4 Alarm window
Alarm window is used to display alarm message when triggering. It controls message display by a bit
address of PLC.

1 Create a new alarm window. It is similar to create a new window. So, it has two ways.
A:①Click “Alarm” in the manage column with your left key to make it in the opposite
color.

B:Insert a window in the console. (The detail operation as the following)


Click the window of the project manage area with your left key to make it the opposite color. Click your
right key, choose “Insert” in the come out menu.

2 There will come out a new alarm window dialog box. Set the window’s name, width, height. Set the
object type and pop period. “no repeat pop” means when the alarm window pop one time ,it will not alarm
again. “5 sec”means pop in the alarm window. Press “OK” to cancel. The alarm window will appear every
five seconds. “10sec”,“30sec”,“1min”,“5min”,“10min”,“30min” is the same as “5 sec”。
Press “OK” to finish setting。

78
TouchWin 使用手册

1. Place a “text” in the correspond position of the alarm window. The content is the
relative alarm message. Such as “temperature too high”.

The operator can take effective measures at once to solve the problem. Press “OK” to close the alarm
window.

79
TouchWin 使用手册

5 Print window

5-1 Create a new print window


It is a bit address message of PLC to control the pop of print window and trigger print action. The
window’s content is the print content.
1. Create a new window. It is similar to create a new window. So, it has two ways.
A:①Click “Print” in the manage textbox with your left key to make it in opposite color. ②Click
“new” in the operate toolbox.

B : Insert a window in the


console. (The following are the
details)
Click the window in the
project manage area with your left
key to make it opposite color.
Click the right key, choose “Insert”
in the pop menu.

2 There will pop out a new print window dialog box. Set its name, width, height. Set its trigger object (a
register bit of PLC. Take M0 for example, when M0=1, the print window pops, at the same time print the
window’s content. When you don’t want to print them, trigger object’s value will be set 0. ) You can also set
the print direction from left to right or from right to left.
Press “OK” to finish setting.

80
TouchWin 使用手册

1. Add the print content you want in the print window’s correspond position and you will
finish print window’s setting.

5-2 Connection of the printer


Printer side TP series touch screen side
9 pin D shape mother seat
Busy 2 RXD

Data 3 TXD

GND 5 GND

6 DSR

NOTE:The printer model Our company use to test is BRIGHTEK WH164Q0108A5,you can refer to
its user manual for its printer.

81
TouchWin 使用手册

6 System parameter

6-1 System setting


Choose system parameter in the file menu. There will pop out a system setting dialog box.

6-1-1 Start up the screen and set up the background

The first screen TP560 displays when give it power. Usually we set the screen with main menu screen or
the screen that will be used most often.

Press set button and you can set the screen’s background color (It can be set white or black.).

6-1-2 Order setting

In a project, all the screen use a common order. If the “password” property of “data setting”, “function
button” etc is effective, only when the system order is undo can the units work. With this function, we can
realize screen hidden and set data password.

6-1-3 Screen protecting

When there is no manpower for the screen, you can choose display certain screen and close background
light. Background light keep time default as 3 minutes, or you can set it freely. When it is set to “no screen
protection”, it means the background light lights all along.

82
TouchWin 使用手册

6-2 Control in turn

Usually, screen switch is fulfilled by button. Except for this, PLC can switch the screen by modifying the
register’s value. If the property is effective, write value n to register D300(example),TP560 will auto
switch the display to the screen n . Then value in D300 will be clear.

TP560 write the current screen number’s data to D301,so the PLC will know the display’s state.

NOTE:The designer can define the multi-control register’s number freely.

6-3 PLC type choosing

According to the display’s communication object, choose PLC model. When TP560 is downing the screen,
transfer the screen’s data along with PLC’s communication protocol which is appointed. So when the
display works, it will pass the protocol to communicate with PLC.

83
TouchWin 使用手册

7 Save and download

7-1 Save the project

After finishing the screen edit, you could save the project file and down the screen project
to TP series touch screen. It will be ready to debug online.

Click button,the screen will pop out a save screen dialog box.

Choose a right route and name to save it .

The file’s extend name will auto defined as *.twp

Input file name, choose a right route, then click “save” to save the screen.

7-2 Download

Connect the computer’s 9 pin RS232 series port and TP series’s download 9 pin series port with download
cables. Make sure that TP series has connected to DC24V. Click button to download data. There will pop
out a download screen data prompt window to prompt data plan.

NOTE:In the process of download screen data, make sure the TP series touch
screen’s power not cut!

After the screen transfer is over, there will pop out a dialog box. It tells that all project screen has
transferred.

84
TouchWin 使用手册

Cut the display’s power off. Pull the screen transfer cable TP-SYS-CAB0 out,connect the PLC’s port of
TP and PLC with PLC communicate cable.
Give power to PLC and display. If communication is normal, they will carry out data monitor and other
operation. If communication failed because of wrong parameter or wrong cable connection, there will be a
“communicating” text in the middle of the display. That means TP and PLC is setting up communication. If
display and PLC can’t communicate normally all along,please check the following:
1、If the PLC model that project choose match with that connected in fact.
2、If they have connected with communication cable
3、If the communication cable is connected right.
4、If PLC’s communication parameter setting is right
5、If you have give PLC and display the power
6、If you have not found the problem, please contact with your supplier.

85
TouchWin 使用手册

8 Special functions
TP series touch screen not only has a terminal display function, it has its own memory area. In the
different area it has different definition and function.

Identifier Definition Definition number Function

PSB bit 0 always ON


1 always OFF
2 the first scan time is ON
3 0.1 sec plus
4 1sec plus
5 1 min plus
PSW byte 1 Start screen’s ID
2 Current screen’s ID

TP series touch screen add a new function to communicate with inverter on the base of original function.
The following we will take mitsubishi FR series transducer for example to describe.
First, open TouchWin edit tool,create a new project:

1. Choose a correspond display, click “next”:

86
TouchWin 使用手册

2. Choose mitsubishi FR series inverter in the table, take “setting” as system default. Click “next”:

3. Input name, author, remark etc, press “OK” to enter edit screen.

87
TouchWin 使用手册

Here we will change the inverter’s inside parameter and input frequency mainly by the touch screen to
control the electric machine roll forth, roll back, stop. At the same time display the transducer’s states of
alarm code, output frequency output voltage and output circuit etc by the touch screen. The following will
give a detail presentation for the unit.
①.Place digital display unit in the screen, open the property dialog box, default it as object
option card. Choose the pull down menu of object:

Alarm codes Correspond to the alarm codes inside the inverter. You can use Chinese to
display the alarm message.
Set frequency Correspond to the set of inverter’s frequency.

88
TouchWin 使用手册

Output frequency Correspond to the output frequency of the inverter.


Output current Correspond to the output current of the inverter
Output voltage Correspond to the output voltage of the inverter
Parameter Correspond to the different parameter inside the inverter, the user can appoint
a certain parameter in the inverter and display it on the touch screen.
Order codes Correspond to the different order codes inside the inverter, the user can
appoint a certain order code to control the frequency and make it do the correspond action.

Click display option card, set it yourself according to the screen’s clue and product demand, just as
the following map:

②.Place Transducer Alarm Information in the screen. Just as the following:

Inverter Alarm information unit’s object option card is the same to Digital display. Here we mainly
introduce display option card’s relative parameter.
Just as the following map:

89
TouchWin 使用手册

Description presentation:
16 Over-circuit is cut off when speeding up
17 Over-circuit is cut off when speed be determined
18 Over-circuit is cut off when speeding down
32 Rebirth over-voltage is cut off when speeding up
33 Rebirth over-voltage is cut off when speed be determined
34 Rebirth over-voltage is cut off when speeding down or stop
48 Inverter over-load open circuit
49 Electric machine over-load open circuit
64 Radiator is over the temperature
96 Loss speed precaution
112 Control-action transistor alarm
128 Output side connect to the ground over-circuit protection
129 Output wrap the phase protect
144 Outside hot relay act
160 Choose unit abnormal
176 Parameter memory abnormal
177 Parameter unit 脱落
178 Retry times exceed
243 Choose unit abnormal
246 CPU error
247 CPU error
0 No alarm information

③.Place button unit in the screen, open the property dialog box as the following map:
Here we will mainly present object option card’s object type, you can refer to other unit’s presentation
for its option card:
Roll forth/Stop Correspond to the transducer’s roll forth or stop state. ON is rolling forth,
OFF is stop.
Roll back/Stop Correspond to the transducer’s output roll back or stop state. ON is rolling
back, OFF is stop.
Rolling state Correspond to the transducer’s output roll state. ON is rolling, OFF is not.
Roll forth and back state Correspond to the transducer’s output roll forth and back state.

90
TouchWin 使用手册

ON means roll forth, OFF means roll back


Alarm Correspond to the transducer’s current inside alarm code
④.You can refer to introduction before for other units’ relative property, here we will not say any
more.

91
TouchWin 使用手册

APPLICATION
1 TP series operate methods

1-1 TP series online communication

After the screen’s data download is over, cut the power off, pull the screen transfer cable OP-SYS-CAB0
out。Connect TP series DOWNLOAD port and PLC communication port with PLC communication cable.
Check if the PLC’s communication parameter is right. Meanwhile, give PLC and TP the power(TP series use
DC 24V power),the display will enter the state of run at once.

NOTE:No matter that PLC is in the state of running or programming, TP series touch screen can
work regularly.

1-2 TP series touch screen orders


In order to improve the machine’s safety, the data in the touch screen must be modified by the
professional people. So, this demands that the touch screen must have the function of data protection. The
following we will introduce the touch screen’s order setting.
1 First, set the system’s parameter.
Choose “file”, then choose “setting” in the pull down menu.

2 There will pop out a system setting dialog box, input the password in order, press “OK” after you finish.
The order has three grades: regular
advance
system
Regular order can only carry out order protection function of normal grade. Advance grade order can
carry out order protection function of high grade and regular grade. When input system order, you can carry
out all the order operation.

92
TouchWin 使用手册

3 Creating of project system. first, set “screen jump” button to make it jump to order page.

4 Press “user input” button to switch to order screen.

93
TouchWin 使用手册

5 Press “open order button” to enter order input screen.

6 Press after inputting the order. If the order is right, there will pop out 1,or else there will pop out
2。

7 Press “Close order”,jump out close order dialog box, but the operation that has order protection cannot
be carried out.

8 Press “back” button to return to the original screen.

94
TouchWin 使用手册

APPENDIX

1 PLC CONNECTION METHODS

1-1 Xinje FC series

TP software setting

Parameter items Recommend setting

PLC model Xinje FC series

Communication port type RS232

Data bit 8

Stop bit 1

Checkout bit Odd check

Baud rate 9600

Bureau ID 1

Address for operation

PLC ID type Operation bound Format Presentation

M 0~383 DDD Assistant point inside

W 0~2047 DDDD Data memory

D means algorism data

95
TouchWin 使用手册

TP-FC- CAB0 connection map

TP series touch screen side FC series PLC side


9 pin D shape mother seat 8 pin round father seat

2 RXD 4 RXD

3 TXD 5 TXD

5 GND 8 GND

8 pin DIN round father seat


pin column

96
TouchWin 使用手册

1-2 mitsubishi FX series

TP software setting

Parameter items Recommend setting

PLC model mitsubishi FX series

Data bit 7

Stop bit 1

Checkout Even check

Baud rate 9600

Bureau ID 0

Address for operation

PLC address bound Operation bound Format Presentation

X① 0~267 O Outside input point

Y① 0~177 O Outside output point

M① 0~1023 D Inside assistant point

S① 0~999 D Special assistant point

T(as states) 0~255 D Timer state

C 0~255 D Counter point

C16 0~199 D 16 bits count

(C32) 200~255 32 bits count

D 0~8255 D Data memory

T(as registers) 0~255 Current value

①X、Y、M、S all can extend as register.

97
TouchWin 使用手册

TP-FX-CAB0 connection map

1 CPU Unit

TP series touch screen side FC series CPU RS422 port


9 pin D shape mother seat 8 pin round shape mother seat

1 TD+ 2 RD-

6 TD- 1 RD+

8 RD- 4 TD-

9 RD+ 7 TD+

5 GND 3 GND

2 Communication unit RS232BD

TP series touch screen side FX series PLC side


9 pin D shape mother seat 8 pin D shape mother seat

2 TX 2 SD

3 RX 3 RD

5 GND 5 GND

98
TouchWin 使用手册

3 Communication unit RS485BD

FX series RS485BD unit


TP series touch screen side RS485 port
9 pin D shape father seat 5 point connect port

RDA

4 A SDA

5 GND SG
7 B RDB

SDB

99
TouchWin 使用手册

1-3 SIEMENS S7-200 series


Software setting

Parameter items Recommend setting

PLC model S7-200

Communication port type RS485

Data bit 8

Stop bit 1

Checkout Even check

Baud rate 9600

Bureau ID 2

Address for operation

PLC address type Operation bound Format Presentation

VB 0~4095 DDDD Byte data register

VW 0~4095 DDDD Word data register

M 0~255.7 DDD.O Inside assistant point

VD 0~4095 DDDD Double word data register


NOTE:D means algorism data

TP-S7-CAB0 connection map


CPU unit

TP series touch screen side S7-200 series PLC side


9 pin D shape mother seat 9 pin round shape mother seat

4 A 3 A

7 B 8 B

100
TouchWin 使用手册

1-4 OMROM C series


Software setting

Parameter items Recommend setting

PLC model OMRON

Communication port type RS232

Data bit 7

Stop bit 2

Checkout Even check

Baud rate 9600

Bureau ID 0

Operation address

PLC address type Operation type Format Presentation

IR 00000~24315 DDD(BB) As points and register

SR 24400~25515 DDD(BB) As points and register

HR 0000~9915 DD(BB) As points and register

AR 0000~2715 DD(BB) As points and register

LR 0000~6315 DD(BB) As points and register

TC 0~512 DDD Timer /counter register’s value

DM 0~6655 DDDD Data register

PV 0~512 DDD Time or counter’s current value

101
TouchWin 使用手册

TP-CQM-CAB0 connection map

TP series touch screen side OMROM PLC side


9 pin D shape mother seat 9 pin D shape father seat

2 RXD 3 RXD

3 TXD 2 TXD

5 GND 9 GND

Presentation:If OMROM PLC can only monitor but modify data, change data in DM6600 as H0201,
give it power again will do.

102
TouchWin 使用手册

1-5 Koyo S series

Software setting

Parameter items Recommend setting

PLC model KOYO

Communication port type RS232

Data bit 8

Stop bit 1

Checkout Odd check

Baud rate 9600

Bureau ID 1

Operation address bound

PLC address bound Operation bound Format Presentation

I 0~477 OOO Outside input point

Q 0~477 OOO Outside output point 0

M 0~377 OOO Inside assistant point

T 0~177 OOO Timer point

C 0~177 OOO Counter point

S 0~777 OOO Step point

R 0~41037 OOOOO Data register

NOTE:O means octal

103
TouchWin 使用手册

TP-SZ-CAB0 connection map

1. CPU unit (DL05/DL105/DL230/DL250/DL350/DL450 RS232 Port)

Direct Logic series


TP series touch screen side
RS232 port
9 pin D shape mother seat
6 feet RJ-11 father seat
2 RXD 4 TX

3 TXD 3 RX

5 GND 1 GND

6 GND

Presentation

DL05 series port1&2、DL240’s port1&2、DL250’ port1、DL350’s port1 and DL450’s port2 are all
hardware port of RJ-11, the connection line is the up map .

RJ-11 6 foot mother seat pin feet arrange

104
TouchWin 使用手册

2. CPU unit(DL250 CPU unit Port2 RS422)

DL250 CPU unit


TP series touch screen side
RS422 port
9 pin D shape mother seat
15 port SVGA port mother seat
8 RD- 10 TX-

9 RD+ 9 TX+

5 GND 7 GND

6 TD- 6 RX-

1 TD+ 13 RX+

11 RTS+

14 CTS+

12 RTS-

15 CTS-

Presentation

DL250 unit’s Port2 combines RS232 and RS422 these two electric port, when using, please pay
attention to their type setting.

3. CPU unit(DL430/DL440/DL450 CPU unit Port1&DL350 CPU unit Port2 RS232)

DL350/405 series CPU


TP series touch screen side
RS232 port
9 pin D shape mother seat
25 pin D shape mother seat
3 TXD 2 TX

2 RXD 3 RX

5 GND 7 GND

4 RTS

5 CTS

105
TouchWin 使用手册

1-6 Delta DVP series

Software setting

Parameter items Recommend setting

PLC model Delta DVP

Communication port type RS232

Data bit 7

Stop bit 1

Checkout Even check

Baud rate 9600

Bureau ID 1

Operation address bound

PLC address type Operation bound Format Presentation

X① 0~377 OOO Outside input point

Y① 0~377 OOO Outside output point

M① 0~1279 DDDD Inside assistant relay

S① 0~1023 DDDD Step point

T 0~255 DDD Timer point

C 0~255 DDD Counter point

D 0~1279 DDDD Data register

TD 0~255 DDD Current value of timer

CD 0~255 DDD Current value of counter

Presentation:D means algorism number,O means octal number

①X、Y、M、S all could be extended as a register.

106
TouchWin 使用手册

TP-DVP-CAB0 connection map

TP series touch screen side Delta DVP series


9 pin D shape mother seat 8 pin round shape father seat

2 RXD 4 RXD

3 TXD 5 TXD

5 GND 8 GND

Presentation:

Delta DVP series PLC contain DVP-14/24/32/60ES00 and DVP-XXESO1 etc model,all can
connected with TP touch screen by program communication port on CPU unit.

107
TouchWin 使用手册

1-7 LG Master-k series PLC

Software setting

Parameter items Recommend setting

PLC model LG Master-k


PLC
PORT2 PORT1
communication port
Modbus
Protocol PRG
Slave
Data bit 8 8

Stop bit 1 1

Checkout Even check No check

Baud rate 9600 34800

Bureau ID 1 1

Operation speed bound

Operation
PLC address type Format Presentation
bound
P① 0~127F DDDH Input/output point

K① 0~31F DDH Keep relay point

M① 0~191F DDDH Inside assistant point

L① 0~63F DDH Connect relay point

F① 0~63F DDH Read only

T 0~255 DDD Timer point

C 0~255 DDD Counter point

TD② 0~255 DDD Current value of timer

CD② 0~255 DDD Current value of counter

D② 0~5119 DDDD Data register

SD② 0~100 DDD Step point


① Can be used as a register。
② Extend to use as a register。

108
TouchWin 使用手册

TP-LG-CAB0 connection map

1. PORT1

TP series touch screen side Master k series CPU


9 pin D shape mother seat 9 pin D shape mother seat

2 RXD 2 RXD

3 TXD 3 TXD

5 GND 5 GND

2. PORT2
Master k series CPU
TP series touch screen side
RS232 port
9 pin D shape mother seat
9 pin D shape mother seat
2 RXD 4 RXD

3 TXD 7 TXD

5 GND 5 GND

109
TouchWin 使用手册

1-8 Panasonic FP series PLC

Software setting

Parameter items Recommend setting

PLC model Panasonic FP


Communication
RS232
port type
Data bit 8

Stop bit 1

Checkout No

Baud rate 9600

Bureau ID 1

**Usually we default FP series PLC’s station number as 1,but FP3 has special control,the station number
must be 0. Please pay attention to communication setting of PLC when connecting.

110
TouchWin 使用手册

Operation address bound

PLC address type Operation bound Format Presentation

X 0~12F DDH Outside input point

WX 0~12 DD As a register

Y 0~12F DDH Outside output point

WY 0~12 DD As a register

R 0~62F 90~903F DDDH Inside assistant point


0~62
WR As a register
900~903
T 0~99 DD Timer point

C 100~143 DD Counter point

SV 0~143 DDD Set value of timer or counter

EV 0~143 DDD Current value of timer or counter

DT 0~9999 DDDD Data register

TP-FP-CAB0 connection map

Presentation

NAIS FP series PLC contains FP0/1/2/3/2SF/10SH etc series, all of them can connect to TP touch
screen by program port on CPU or communication port.

1. CPU unit RS232

TP series touch screen side FP0/FP2/FP2SH/FPM CPU


9 pin D shape mother seat 5 pin DIN round shape mother seat

2 RXD 3 RXD

3 TXD 2 TXD

5 GND 1 GND

111
TouchWin 使用手册

FP1/FP2/GP2SH/FP10SH CPU
TP series touch screen side
RS232 port
9 pin D shape mother seat
9 pin D shape mother seat
2 RXD 3 TXD

3 TXD 2 RXD

5 GND 5 GND

1 CD

7 RTS

8 CTS

4 DTR

6 DSR

5 pin mother seat pipe feet range

Presentation

In FP0 series only FP0-CXXCXX model has RS232 communication port.

112
1-9 Schneider Electric PLC

TP software setting

Parameter items Recommend setting

PLC model Schneider Electric


Communication
RS485
port type
Protocol MODBUS
Transfer frame’s
RTU
MODE
Data bit 8

Stop bit 1

Checkout Even check

Baud rate 9600

Bureau ID 1

Operation address bound

PLC address type Operation type Format Presentation

M 0~2047 DDDD Inside point

MW 0~2047 DDDD Register point

TP-NEZA-CAB0 connection map

TP series touch screen side Schneider Electric PLC side


9 pin D shape mother seat 8 pin D shape father seat

4 A 1 A

7 B 2 B