Schneider Electric - Acti9-AFDD - A9T26620

The document provides specifications for the Acti9 iDPN N VigiARC C 20A Arc Fault Detection Circuit Breaker, detailing its features, compliance standards, and technical specifications. It includes information on electrical ratings, physical dimensions, environmental conditions, and packaging. Additionally, it outlines the manufacturer's commitment to sustainability and environmental compliance.

Uploaded by

mksaudiaid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views4 pages

Schneider Electric - Acti9-AFDD - A9T26620

The document provides specifications for the Acti9 iDPN N VigiARC C 20A Arc Fault Detection Circuit Breaker, detailing its features, compliance standards, and technical specifications. It includes information on electrical ratings, physical dimensions, environmental conditions, and packaging. Additionally, it outlines the manufacturer's commitment to sustainability and environmental compliance.

Uploaded by

mksaudiaid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Product data sheet

Specifications

Arc Fault Detection Circuit Breaker,


Acti9, iDPN N VigiARC C 20A
6000A 30mA Type A 20A
A9T26620

Main
Range Acti9

product name Acti9 iDPN N VigiARC

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product or component type Arc fault detection RCBO

Product specific application Arc fault detection

Standards EN/IEC 62606


AS/NZS 61009.1

Device short name iDPN N VigiARC

Poles description 1P + N

Number of protected poles 1

Curve code C

Breaking capacity 6000 A at 240 V AC 50 Hz conforming to AS/NZS 61009.1

Rated breaking and making Idm 500 A at 240 V AC 50 Hz conforming to AS/NZS 61009.1
capacity
Neutral position Left

network type AC

Earth-leakage protection time Instantaneous


delay
Earth-leakage protection class Class A

Suitability for isolation Yes

Residual current tripping Voltage dependent


technology
Trip unit technology Thermal-magnetic

Earth-leakage protection Integrated

Complementary
[In] rated current 20 A

Network frequency 50 Hz

[Ue] rated operational voltage 230/240 V AC 50 Hz conforming to AS/NZS 61009.1


230/240 V AC 50 Hz conforming to IEC 62606

Device location in system Outgoer

Magnetic tripping limit 5...10 x In

Limitation class 3 conforming to AS/NZS 61009.1

[Ui] rated insulation voltage 250 V AC 50 Hz between phase and neutral


400 V AC 50 Hz between phases

Threshold tripping voltage 275 V for +/- 5 V

11/02/2025 1
[Uimp] rated impulse withstand 4 kV conforming to AS/NZS 61009.1
voltage
Contact position indicator Yes

Control type Toggle

Local signalling ON, OFF, fault trip

Mounting mode Clip-on

Mounting support DIN rail

Colour White

Mechanical durability 20000 cycles

Electrical durability 20000 cycles 240 V AC 50 Hz conforming to AS/NZS 61009.1

overvoltage category III

Locking options description Padlocking device

cable entry Top and bottom

Connections - terminals Tunnel type terminal for 2 cable(s) 2.5 mm² rigid
Tunnel type terminal for 1 cable(s) 16 mm² rigid
Tunnel type terminal for 2 cable(s) 2.5 mm² flexible
Tunnel type terminal for 1 cable(s) 10 mm² flexible

Wire stripping length 14 mm

Tightening torque 2 N.m

Comb busbar and distribution YES


block compatibility
9 mm pitches 4

Height 91 mm

Width 36 mm

Depth 75 mm

Product weight 205 g

Environment
Heat dissipation 4.62 W at 240 V - 20 A

IP degree of protection IP20 conforming to IEC 60529

Pollution degree 2 conforming to AS/NZS 61009.1


2 conforming to IEC 62606

Tropicalisation Severity B conforming to IEC 60068-2-30 for 28 d

Relative humidity 95 % at 55 °C

Operating altitude 2000 m

Ambient air temperature for -25…60 °C


operation
Ambient air temperature for -40…80 °C
storage
Quality labels RCM

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Height 7.5 cm

Package 1 Width 3.6 cm

2 11/02/2025
Package 1 Length 9.1 cm

Package 1 Weight 237.0 g

Contractual warranty
Warranty 24 months

11/02/2025 3
Environmental Data

Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.

Environmental Data explained

How we assess product sustainability

Environmental footprint

Environmental Disclosure Product Environmental Profile

Use Better

Materials and Substances

Packaging made with recycled cardboard No

Packaging without single use plastic No

EU RoHS Directive Compliant with Exemptions

SCIP Number B078722f-7853-4e1e-a05b-29638f57b0ab

REACh Regulation REACh Declaration

China RoHS Regulation China RoHS declaration

PVC free No

Use Again

Repack and remanufacture

Circularity Profile End of Life Information

Take-back No