Kollmorgen offers a range of explosion-proof motors certified to UL, ATEX, and IECEx standards for use in hazardous locations, ensuring safety in environments with potential explosive atmospheres. The motors include various series such as EB, EBH, PMDC, AC Synchronous, and Stepper MX, designed for different applications and operational requirements. Key features include robust construction, dynamic performance capabilities, and compliance with international safety regulations.

Uploaded by

juan.14f1999
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views

Explosion Proof_Brochure_Final

Kollmorgen offers a range of explosion-proof motors certified to UL, ATEX, and IECEx standards for use in hazardous locations, ensuring safety in environments with potential explosive atmospheres. The motors include various series such as EB, EBH, PMDC, AC Synchronous, and Stepper MX, designed for different applications and operational requirements. Key features include robust construction, dynamic performance capabilities, and compliance with international safety regulations.

Uploaded by

juan.14f1999
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Hazardous Location Performance

Explosion Proof Motors


UL, ATEX and IECEx Certified
Explosion Proof Motors

The Certifications
You Need.
The Performance
You Demand.
EB & EBH Series PMDC Series
Variable speed, dynamic load, brushless servo motors, Fixed speed, constant load, brushed permanent
230 and 480 Vac magnet DC motors, up to 180 Vdc

Motors for use in hazardous locations must be engineered to prevent the


ignition of potentially explosive atmospheres and must be certified by the
responsible governing body in each region where the motor is used.

Kollmorgen offers motors certified to UL, ATEX and IECEx All explosion proof motors are designed and built to
explosion proof standards, meeting regulatory requirements Kollmorgen’s uncompromising quality standards to ensure
in countries around the world. Typical applications include years of reliable operation in harsh and rugged industrial
mining, oil and natural gas refining, flour mills, grain environments.
elevators, textile mills, industrial paint booths and other
environments subject to hazardous atmospheres where For complete details and specifications, and to order, visit
ignitable gases, dusts, fibers or flyings may be present. www.kollmorgen.com/en-us/products/motors/explosion-proof

AC Synchronous Series Stepper MX Series


Key safety features include motor enclosures capable of
withstanding an internal explosion, flame paths that prevent Fixed speed, constant load, brushless AC synchronous Variable speed, constant load, brushless stepper
any internal flame or spark from reaching the outside motors, 120 & 240 Vac, 50/60 Hz motors, up to 240 Vac
environment, and surface temperatures that never become
hot enough to ignite hazardous materials, even when the
motor is in an overload condition or when it is covered by a
layer of hazardous dust.

2 www.kollmorgen.com 3
Explosion Proof Motors

EB & EBH Series PMDC EP Series


Brushless Servo Motors Brush Permanent Magnet DC Motors
UL, File E120721 ATEX, File ITS12ATEX17548X UL, File E56538
Class I, Divisions 1 & 2, (EB-80x excluded) Class I, Divisions 1 & 2, Groups C & D
Groups C & D Ex II 2 G Ex d IIB T3 Gb –40°C ≤ Ta ≤ +40°C Class II, Division 1 & 2, Groups F & G
IECEx ETL 12.0006X Class III, Divisions 1 & 2

EB and EBH servo motors offer EB Series PMDC EP (explosion proof) motors are brushed, permanent Anti-cog magnets allow for smooth low-speed operation,
superior torque density and high magnet DC motors for use in fixed-speed, constant load and these motors feature high overcurrent capacity and
Frame Size EB10x EB20x EB40x EB60x EB80x
maximum speeds. The EB Series is applications. They are available in a NEMA 56C frame size dynamic braking capabilities. A long, reliable operational life is
Stack length 2,4,6 2,4,6 2,4,6 2,4,6 2,4,6
available with a voltage range up to with a TENV (totally enclosed, non-ventilated) configuration ensured through Class H insulation; a polyester-impregnated
Windings A,B A,B,C,D A,B,C,D A,B,C,D A,B,C and are capable of power ranges from 1/4 to 3/4 hp. armature; rugged, fused commutator; large sealed bearings;
230 Vac, while the EBH Series has a
higher voltage range up to 480 Vac. Rated voltage (Vrms) 230 230 230 230 230 and long-life, constant-force brush springs with field-
Both series are available in speeds Max cont. stall torque (Nm)* 2.22 6.44 18.6 44.8 108.5 replaceable brushes.
up to 7,500 rpm. Max peak torque (Nm)* 6.36 19.96 49.5 131.9 362

Max rated speed (rpm) 7500 7000 5000 4300 3000


These motors include rugged PMDC EP Series Parameters
Max rated power (hp) 2 4.53 9.6 14.2 21.2
resolver feedback, a built-in

Continuous Current

Continuous Torque
thermostat and Class F* insulation. * @ 40°C ambient

Inductance (mH)
Torque Constant
Peak Current (A)

Inertia (lb1-in/A)
Resistance (Ω)
Product Code
They are ideally suited for use in

Enclosure

(lb1-in/A)
(lb1-in)
NEMA
HP Model Number

(A)
applications that require highly
EBH Series
dynamic motion, including variable
speeds and varying loads, and in Frame Size EBH12x EBH22x EBH42x EBH62x

locations where flammable vapors Stack length 2,4,6 2,4,6 2,4,6 2,4,6
1/4 EP3624-1434-7-56BC-CU FGE0212 56C TENV 2.6 9.0 52.0 4.07 2.63 4.0 10.5
or gases create a potentially Windings A, B A, B, C, D, E A, B, C, D A, B, C, D, E
1/3 EP3632-1435-7-56BC-CU FGE0242 56C TENV 3.5 12.0 71.0 3.94 1.76 5.0 6.6
hazardous environment.

90V
Rated voltage (Vrms) 480 480 480 480
1/2 EP3640-1436-7-56BC-CU FGE0213 56C TENV 4.7 18.0 87.0 4.24 1.03 6.4 5.1
Max cont. stall torque (Nm)* 1.89 5.59 15.80 36.7
3/4 EP3758-5151-7-56BC-CU FGE0248 56C TENV 7.0 27.0 113.0 4.15 0.74 8.0 3.8
Max peak torque (Nm)* 6.35 20.2 49.5 126.0

Max rated speed (rpm) 7500 7000 5000 4500


1/4 EP3624-5269-7-56BC-CU FGE0261 56C TENV 1.3 9.0 26.0 8.10 10.50 4.0 51.80
Max rated power (hp) 1.57 4.0 7.89 11.56

180V
1/2 EP3644-5214-7-56BC-CU FGE0262 56C TENV 2.3 18.0 34.0 8.10 4.00 6.7 24.20
* @ 40°C ambient
3/4 EP3752-5215-7-56BC-CU FGE0263 56C TENV 3.3 27.0 38.0 8.10 3.10 11.4 17.40

EB motors can be ordered in either cULus or ATEX/IECEx + cETLus configurations.

12V
EBH motors can only be ordered with ATEX/IECEx configurations. These configurations, and 1/3 EP3620-1954-7-56BC-CU FGE0243 56C TENV 28.0 12.0 n/a 0.52 0.04 3.5 0.18
their corresponding certifications, are mutually exclusive. UL configurations do not have ATEX/
IECEx. ATEX/IECEx+cETLus have the ETL listed mark instead of the UL listed mark,
using equivalent UL and CSA standards.

ATEX/IECEx certification is not available for EB80x sizes. 1/3 EP3624-2757-7-56BC-CU FGE0245 56C TENV 13.4 12.0 n/a 1.02 0.16 4.0 0.66
24V

3/4 EP3648-4952-7-56BC-CU FGE0244 56C TENV 28.2 27.0 n/a 1.02 0.06 7.1 0.22

4 www.kollmorgen.com 5
Explosion Proof Motors

AC Synchronous Motors Stepper MX Series


UL, File E32246 UL, File E32246 (MX9) and E120721 (MX11)
Class I, Divisions 1 & 2, Group D Class I, Divisions 1 & 2, Group D

These hazardous-duty synchronous motors provide torque Explosion proof MX Series stepper motors are available in MX Series steppers are available with bipolar windings and a
up to 1,500 oz-in (1059 N-cm) and are available in NEMA 42 NEMA 34 and 42 frame sizes (90 and 110 mm). They move in choice of stack lengths, providing speeds up to 3,000 rpm to
and 66 frame sizes (110 mm and 170 mm). They run at 72 rpm 200 steps per revolution (1.8° step angle) and provide minimum meet the velocity demands of most high-torque applications.
with a 120 Vac or 240 Vac, 60 Hz power supply, or 60 rpm with holding torques from 1.27 to 9.82 N-m (180 to 1,390 oz-in).
a 240 Vac, 50 Hz power supply.

MX9 Series Stepper Motors, NEMA 34


120 Volt, 60 Hz, Single Phase, 72 rpm Phase Shifting Shaft Loading
Rated
Holding Torque (2 Phase Phase Detent Thermal Rotor
Torque (min) Load Inertia* Amps Wiring Resistor Capacitor (330VAC) Config. Current/ Weight Radial Axial
phases on) Resistance Inductance Torque Resistance Inertia
Model Diagram Phase Force Force
Motor Model
oz-in N-cm lb-in2 kg-cm2 Kit Number Ohms Watts Kit Number µF Number

Unipolar
oz-in-s2

Parallel

Series
X250 250 177 3 8.8 0.6 RC 201052-013 150 50 201053-010 6.5 oz-in mH oz-in Mounted lb
Amps DC Ohms +/-10% (kg-m2 lb (N) lb (N)
(Nm) +/-10% Typical (Nm) °C/Watt (kg)
x 103)
X700 700 494 10 30 1.1 RC 201052-027 150 100 201053-032 12.5
MX91-FF-206U • 3.0 1.0 10
X1100 1,100 777 9 26 3 RC 201052-025 100 160 201053-026 17.5 180 0.0095 6.0 25 50
MX91-FF-402U • 4.0 0.72 6.0 2.0 2.9
(1.27) (0.067) (2.7) (111) (222)
X1500 1,500 1,059 12 35 3 RC 201052-020 55 375 201053-014 30 MX91-FF-403U • 6.0 0.18 1.5
MX92-FF-206U • 370 4.0 1.0 11 0.0174 9.0 25 50
4.0 1.7
MX92-FF-401U • (2.61) 7.0 0.28 2.8 (0.123) (4.1) (111) (222)
240 Volt, 60 Hz, Single Phase, 72 rpm Phase Shifting MX93-FF-206U • 4.0 0.90 13
MX93-FF-401U • 550 5.0 0.65 8.0 0.0265 11 25 50
7.0 2.1
Torque (min) Load Inertia* Amps Wiring Resistor Capacitor (330VAC) (3.88) (0.187) (5.0) (111) (222)
MX93-FF-402U • 7.0 0.16 2.0
Model Diagram
oz-in N-cm lb-in2 kg-cm2 Kit Number Ohms Watts Kit Number µF

X252 250 177 3 8.8 0.4 RC 201052-015 500 50 201053-012 1.75


MX11 Series Stepper Motors, NEMA 42
X1102 1,100 777 9 26 1.5 RC 201052-026 400 160 201053-028 4
Shaft Loading
Rated
X1502 1,500 1,059 12 35 1.5 RC 201052-018 250 200 201053-016 8 Holding Torque (2 Phase Phase Detent Thermal Rotor
Config. Current/ Weight Radial Axial
phases on) Resistance Inductance Torque Resistance Inertia
Phase Force Force
X1500 1,500 1,059 12 35 3 RC 201052-020 55 375 201053-014 30 Motor Model
Number

Unipolar
oz-in-s2

Parallel

Series
oz-in mH oz-in Mounted lb
Amps DC Ohms +/-10% (kg-m2 lb (N) lb (N)
240 Volt, 60 Hz, Single Phase, 60 rpm Phase Shifting (Nm) +/-10% Typical (Nm) °C/Watt (kg)
x 103)

Torque (min) Load Inertia* Amps Wiring Resistor Capacitor (330VAC) 6.0 0.55 10 25 50
Model Diagram MX111 • 850 (6.0) 1.1 3.6 16 7.4
(4.24) (393) (4.5) (111) (222)
oz-in N-cm lb-in 2
kg-cm 2
Kit Number Ohms Watts Kit Number µF
12 0.114 18 25 50
X252 250 177 3 8.8 0.4 RC 201052-015 500 50 201053-012 1.75 MX112 • 1390 (9.82) 2.7 2.5 2.5 1.8
(8.47) (806) (8.2) (111) (222)
X1102 1,100 777 9 26 1.5 RC 201052-026 400 160 201053-029 6

X1502 1,500 1,059 12 35 1.5 RC 201052-018 250 200 201053-019 9

X1500 1,500 1,059 12 35 3 RC 201052-020 55 375 201053-014 30

*This is the maximum rigidly attached load inertia the motor will reliably start.
If the load is attached to the motor with a coupling that has a 5º flex, the
motor can start loads up to seven times listed.

6 www.kollmorgen.com 7
About Kollmorgen
Kollmorgen, a Regal Rexnord brand, has more
than 100 years of motion experience, proven
in the industry’s highest-performing, most
reliable motors, drives, linear actuators, AGV
control solutions and automation platforms.
We deliver breakthrough solutions that are
unmatched in performance, reliability and ease
of use, giving machine builders an irrefutable
marketplace advantage.

www.kollmorgen.com

Specifications are subject to change without notice. It is the


responsibility of the product user to determine the suitability of this
product for a specific application. All trademarks are the property of KM_BR_000412_RevA_EN
their respective owners. ©2023 Kollmorgen Corporation. All rights reserved

You might also like