Firmware Up Gradation Procedure in Sun 3510 Storedges
Firmware Up Gradation Procedure in Sun 3510 Storedges
3) Download the latest Firmware patch file and save it in the tmp directory and
extract them.
# jar xvf 113723-18.jar
113723-18.jar hsperfdata_root ssmon.err
113723-20
META-INF
ssmon.out
ssserver.err
ssserver.out
# cd 113723-20
# ls
JBOD_upgrade.txt
LEGAL_LICENSE.TXT
patchinfo
pld1r10.s3r
README.113723-20
sesfw_3510_1103.s3r
SUN421F-3510.bin
SUN-STOREDGE-3510-MIB.txt
1) For the SES firmware upgrade, first verify the SES firmware version
sccli> show ses-devices
Ch Id Chassis Vendor/Product ID
Rev PLD WWNN
------------------------------------------------------------------------------2 12 019626 SUN StorEdge 3510F A 1080 A000 204000C0FF019626
2) Since the SSCS agent may interfere with the download of SES code, its necessary
to stop any SSCS agent:
# /etc/init.d/ssagent stop
3) Upgrade the SES firmware
sccli> download ses-firmware sesfw_3510_1103.s3r
Are you sure? y
SES Device List:
SES Device(CH-2, ID-12)
Download sesfw_3510_1103.s3r to SES Device (CH-2, ID-12)...
SES # 1: CH 2 ID 12, INQ STR: SUN
Where sesfw_3510_1102.s3r is present in the directory where the patch has been
unpacked and its name may vary with the version.
4) Verify that all the SES devices have been upgraded:
Sccli> show ses-devices
Ch Id Chassis Vendor/Product ID
Rev PLD WWNN
------------------------------------------------------------------------------2 12 019626 SUN StorEdge 3510F A 1103 A000 204000C0FF019626