Ups Pinnacle Plus
Ups Pinnacle Plus
The Alpha Pinnacle Plus Uninterruptible Power Supply (UPS), in tower or rack mount configurations
provides safe, clean, reliable power protection to data and voice networking equipment, telecommunication
systems, servers and other mission-critical applications. The Pinnacle Plus offers and advanced fully
digitized microprocessor controlled technology can quickly react to varying output conditions and continually
offer pure sine wave power to cricital equipment with zero transfer time. The advanced, scalable battery
charger shortens the battery recharge time while prolonging the life of the battery. With true RS-232
two-way communication that sends signals to both the network and computer, the Pinnacle Plus can
be monitored, shut down, or programmed with an on/off date, using its own software. Simplified control
circuits make it light, easier to control, and more reliable due to the reduction of internal components.
Alpha Pinnacle Plus
Nominal Specifications
Model
Tower Part Number: PIN 1000TXL 017-751-10 PIN 1500TXL 017-751-15 PIN 2000TXL 017-751-20 PIN 3000TXL 017-751-30
Rack Mount 2U Part Number: PIN 1000RMXL 017-751-122 PIN 1500RMXL 017-751-17 PIN 2000RMXL 017-751-22 PIN 3000RMXL 017-751-32
Capacity (VA/W): 1000VA/700W 1500VA/1050W 2000VA/1400W 3000VA/2100W
Input Plug: NEMA 5-15P NEMA 5-15P NEMA L5-20P NEMA L5-30P
Input Protection: Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker
Receptacles
Tower Dimensions (in): 6W x 16.5D x 9.4H 6W x 16.5D x 9.4H 8.9W x 16.7D x 14.2H 8.9W x 16.7D x 14.2H
Tower Dimensions (mm): 152.4W x 419.1D x 238.8H 152.4W x 419.1D x 238.8H 226.1W x 424.2D x 360.7H 226.1W x 424.2D x 360.7H
Tower Net Weight (lb/kg): 35.3/16 37.5/17 68.3/31 72.8/33
Tower Approx. Ship Weight (lb/kg): 40/18.2 41.8/19 73.9/33.3 78.1/35.5
Rack Mount Dimensions (in): 16.9W x 16.7D x 3.3H 16.9W x 16.7D x 3.3H 16.9W x 25D x 3.3H 16.9W x 25D x 3.3H
Rack Mount Dimensions (mm): 429.3W x 424.2D x 83.8H 429.3W x 424.2D x 83.8H 429.3W x 609.6D x 83.8H 429.3W x 609.6D x 83.8H
Rack Mount Net Weight (lb/kg): 37.5/17 39.7/18 70.6/32 72.8/33
Rack Mnt Approx. Ship Weight (lb/kg): 42.5/19.3 44.2/20.1 74.4/33.8 78.5/35.7
Battery Runtimes*
Nominal Specifications
Model
Tower Part Number: PIN 6000TXL 017-751-400 PIN 10000TXL 017-757-300 PIN 12000TXL 017-751-15
Capacity (VA/W): 6000VA/4200W 10000VA/7000W 12000VA/8400W
Input Plug: Terminal Block Terminal Block Terminal Block
Input Protection: Circuit Breaker Circuit Breaker Circuit Breaker
Receptacles
Tower Dimensions (in): 10.1W x 23.2D x 22.4H 10.1W x 27.2D x 28.2H 13.5W x 27.2D x 34.6H
Tower Dimensions (mm): 257W x 590D x 570H 257W x 690D x 715H 342W x 690D x 878H
Tower Net Weight (lb/kg): Consult Factory Consult Factory Consult Factory
Tower Approx. Ship Weight (lb/kg): Consult Factory Consult Factory Consult Factory
Battery Runtimes*
General Specifications
AC Input Interface
Voltage (Selectable): 100/110/115/120/127V (PIN 700 to 3K) Front Panel Indicators: LCD display/input/output volts, frequency, load
200/208/220/230/240 (PIN 6 to 12K) level, battery capacity, online/eco mode
Voltage Range: 80 to 144V at full load, 60 to 144V at Audible Alarm: On Battery – 5 second interval, UPS
40% load (120V Units) fault – continuous
Frequency: 50/60Hz ±5% (auto sensing) Communications: RS-232, communications expansion slot, USB
standard (Options: AS400 Card,
AC Output UPS LAN Card)
Voltage: 100/110/115/120/127V (PIN 700 to 3K)
Environment
200/208/220/230/240 (PIN 6 to 12K)
Frequency: 50 or 60Hz ±0.5% when on battery Operating Temperature: 0 to 40°C
Receptacle Segments: 2 – software controllable Storage Temperature: -20 to 50°C
Voltage THD, Linear Load: <3% Altitude: 3500m above sea level
Crest Factor: 3:1 Humidity: 0 to 95%, non-condensing
Overload Capacity: 125% for 1min, 150% for 10sec Audible Noise: <40dBA at 1m
Transfer Time: 0ms Safety: UL, CSA
Extended Battery EMC (EMS/EMI): IEC 61000-4. FCC Part 15, CISPR22
Recharge Time: <4hrs to 90% recharge on internal battery High Efficiency Mode: >95% efficient when selected
Type: Valve Regulated Lead Acid (VRLA)
Extended battery connection included.
Extended battery packs available
BATTERY CHARGER
BATTERY CHARGER
BATTERY
BATTERY
Alpha Pinnacle Plus
Self-Diagnostic Function
Once the UPS is powered on, the unit automatically monitors for fault conditions, protects itself and
the load from any of the these conditions and displays a comprehensive error code.
Alpha Technologies Toll free: 1 800 667 8743 Direct: 604 430 1476 #049-032-10-007 (03/09)
Due to continuous product improvement and modifications, Alpha Technologies reserves the right to make changes to the products and information contained in this
document without notice. Copyright © 2009 Alpha Technologies. All Rights Reserved. Alpha® is a registered trademark of Alpha Technologies. Member of The Alpha
Group™ is a trademark of Alpha Technologies.