0% found this document useful (0 votes)
73 views4 pages

Ups Pinnacle Plus

The Alpha Pinnacle Plus UPS offers reliable power protection for critical applications with models ranging from 1000VA to 12000VA. It features true online, double conversion operation, hot-swappable batteries, and advanced digital signal processing for real-time monitoring. Additional capabilities include automatic frequency synchronization, optional Ethernet SNMP communications, and a user-friendly LCD display for monitoring UPS status.

Uploaded by

erickalanperez3
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
73 views4 pages

Ups Pinnacle Plus

The Alpha Pinnacle Plus UPS offers reliable power protection for critical applications with models ranging from 1000VA to 12000VA. It features true online, double conversion operation, hot-swappable batteries, and advanced digital signal processing for real-time monitoring. Additional capabilities include automatic frequency synchronization, optional Ethernet SNMP communications, and a user-friendly LCD display for monitoring UPS status.

Uploaded by

erickalanperez3
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Alpha Pinnacle Plus

1000VA to 12kAV models

True online, double conversion operation (zero transfer time)

Internal Static Bypass

Automatic Frequency Synchronization

Power factor correction

Optional Ethernet SNMP communications interface

Hot swappable batteries

The Alpha Pinnacle Plus Uninterruptible Power Supply (UPS), in tower or rack mount configurations
provides safe, clean, reliable power protection to data and voice networking equipment, telecommunication
systems, servers and other mission-critical applications. The Pinnacle Plus offers and advanced fully
digitized microprocessor controlled technology can quickly react to varying output conditions and continually
offer pure sine wave power to cricital equipment with zero transfer time. The advanced, scalable battery
charger shortens the battery recharge time while prolonging the life of the battery. With true RS-232
two-way communication that sends signals to both the network and computer, the Pinnacle Plus can
be monitored, shut down, or programmed with an on/off date, using its own software. Simplified control
circuits make it light, easier to control, and more reliable due to the reduction of internal components.
Alpha Pinnacle Plus

Nominal Specifications
Model

Tower Part Number: PIN 1000TXL 017-751-10 PIN 1500TXL 017-751-15 PIN 2000TXL 017-751-20 PIN 3000TXL 017-751-30
Rack Mount 2U Part Number: PIN 1000RMXL 017-751-122 PIN 1500RMXL 017-751-17 PIN 2000RMXL 017-751-22 PIN 3000RMXL 017-751-32
Capacity (VA/W): 1000VA/700W 1500VA/1050W 2000VA/1400W 3000VA/2100W
Input Plug: NEMA 5-15P NEMA 5-15P NEMA L5-20P NEMA L5-30P
Input Protection: Circuit Breaker Circuit Breaker Circuit Breaker Circuit Breaker
Receptacles

Tower: 6 NEMA 5-15R 6 NEMA 5-15R 10 NEMA 5-20R 10 NEMA 5-15R


1 NEMA L5-20R 1 NEMA L5-30R
Rack Mount: 6 NEMA 5-15R 4 NEMA 5-15R 2 NEMA 5-20R 2 NEMA 5-15R
1 NEMA L5-20R 1 NEMA L5-30R
Battery

DC Voltage: 36V 36V 72V 72V


Mechanical

Tower Dimensions (in): 6W x 16.5D x 9.4H 6W x 16.5D x 9.4H 8.9W x 16.7D x 14.2H 8.9W x 16.7D x 14.2H
Tower Dimensions (mm): 152.4W x 419.1D x 238.8H 152.4W x 419.1D x 238.8H 226.1W x 424.2D x 360.7H 226.1W x 424.2D x 360.7H
Tower Net Weight (lb/kg): 35.3/16 37.5/17 68.3/31 72.8/33
Tower Approx. Ship Weight (lb/kg): 40/18.2 41.8/19 73.9/33.3 78.1/35.5
Rack Mount Dimensions (in): 16.9W x 16.7D x 3.3H 16.9W x 16.7D x 3.3H 16.9W x 25D x 3.3H 16.9W x 25D x 3.3H
Rack Mount Dimensions (mm): 429.3W x 424.2D x 83.8H 429.3W x 424.2D x 83.8H 429.3W x 609.6D x 83.8H 429.3W x 609.6D x 83.8H
Rack Mount Net Weight (lb/kg): 37.5/17 39.7/18 70.6/32 72.8/33
Rack Mnt Approx. Ship Weight (lb/kg): 42.5/19.3 44.2/20.1 74.4/33.8 78.5/35.7
Battery Runtimes*

Tower at 50% Load


UPS: 18 min 14 min 18 min 14 min
1 EBP: 148 min 92 min 80 min 50 min
2 EBP: 310 min 205 min 150 min 93 min
Tower at 100% Load
UPS: 6 min 5 min 6 min 5 min
1EBP: 69 min 38 min 33 min 19 min
2 EBP: 150 min 80 min 69 min 40 min
Rack at 50% Load
UPS: 18 min 14 min 18 min 14 min
1 EBP: 148 min 92 min 80 min 50 min
2 EBP: 310 min 205 min 150 min 93 min
Rack at 100% Load
UPS: 6 min 5 min 6 min 5 min
1 EBP: 69 min 38 min 33 min 19 min
2 EBP: 90 min 80 min 69 min 40 min
* rounded to the nearest minute

Nominal Specifications
Model

Tower Part Number: PIN 6000TXL 017-751-400 PIN 10000TXL 017-757-300 PIN 12000TXL 017-751-15
Capacity (VA/W): 6000VA/4200W 10000VA/7000W 12000VA/8400W
Input Plug: Terminal Block Terminal Block Terminal Block
Input Protection: Circuit Breaker Circuit Breaker Circuit Breaker
Receptacles

Tower: Terminal Block Terminal Block Terminal Block


Battery

DC Voltage: 240V 240V 240V


Mechanical

Tower Dimensions (in): 10.1W x 23.2D x 22.4H 10.1W x 27.2D x 28.2H 13.5W x 27.2D x 34.6H
Tower Dimensions (mm): 257W x 590D x 570H 257W x 690D x 715H 342W x 690D x 878H
Tower Net Weight (lb/kg): Consult Factory Consult Factory Consult Factory
Tower Approx. Ship Weight (lb/kg): Consult Factory Consult Factory Consult Factory
Battery Runtimes*

Tower at 50% Load


UPS: 19 min 37 min 53 min
Tower at 100% Load
UPS: 6 min 13 min 19 min
Alpha Pinnacle Plus

General Specifications

AC Input Interface
Voltage (Selectable): 100/110/115/120/127V (PIN 700 to 3K) Front Panel Indicators: LCD display/input/output volts, frequency, load
200/208/220/230/240 (PIN 6 to 12K) level, battery capacity, online/eco mode
Voltage Range: 80 to 144V at full load, 60 to 144V at Audible Alarm: On Battery – 5 second interval, UPS
40% load (120V Units) fault – continuous
Frequency: 50/60Hz ±5% (auto sensing) Communications: RS-232, communications expansion slot, USB
standard (Options: AS400 Card,
AC Output UPS LAN Card)
Voltage: 100/110/115/120/127V (PIN 700 to 3K)
Environment
200/208/220/230/240 (PIN 6 to 12K)
Frequency: 50 or 60Hz ±0.5% when on battery Operating Temperature: 0 to 40°C
Receptacle Segments: 2 – software controllable Storage Temperature: -20 to 50°C
Voltage THD, Linear Load: <3% Altitude: 3500m above sea level
Crest Factor: 3:1 Humidity: 0 to 95%, non-condensing
Overload Capacity: 125% for 1min, 150% for 10sec Audible Noise: <40dBA at 1m
Transfer Time: 0ms Safety: UL, CSA
Extended Battery EMC (EMS/EMI): IEC 61000-4. FCC Part 15, CISPR22
Recharge Time: <4hrs to 90% recharge on internal battery High Efficiency Mode: >95% efficient when selected
Type: Valve Regulated Lead Acid (VRLA)
Extended battery connection included.
Extended battery packs available

Extended Battery Pack Specifications for Pinnacle Plus Tower

Battery Pack: PINBP700T PINBP1000/1500T PINBP1000/1500T PINBP2/3000T PINBP2/3000T PINBP6000T PINBP10000/


Alpha Part Number: 033-751-07 033-751-10 033-751-10 033-751-20 033-751-20 033-751-400 017-751-311
Dimensions (in): 8.9W x 16.7D x 14.2H 8.9W x 16.7D x 14.2H 8.9W x 16.7D x 14.2H 8.9W x 16.7D x 14.2H 8.9W x 16.7D x 14.2H TBA TBA
(mm): 226W x 424D x 360H 226W x 424D x 360H 226W x 424D x 360H 226W x 424D x 360H 226W x 424D x 360H TBA TBA
Weight (lb/kg): 70.5/32 92.6/42 92.6/42 92.6/42 92.6/42 TBA TBA
Approx. Ship Weight (lb/kg): 76.1/34.5 98.1/44.5 98.1/44.5 98.1/44.5 98.1/44.5 TBA TBA

Extended Battery Pack Specifications for Pinnacle Plus Rack Mount


Battery Pack: PINBP700RM PINBP1000/1500RM PINBP1000/1500RM PINBP2/3000RM PINBP2/3000RM
Alpha Part Number: 033-751-08 033-751-12 033-751-12 033-751-22 033-751-22
Dimensions (in): 16.9W x 25D x 3.3H 16.9 x 25 x 3.3H 16.9 x 25 x 3.3H 16.9 x 25 x 3.3H 16.9 x 25 x 3.3H
(mm): 429.3W x 635D x 83.8H 429.3W x 635D x 83.8H 429.3W x 635D x 83.8H 429.3W x 635D x 83.8H 429.3W x 635D x 83.8H
Weight (lb/kg): 73.9/33.5 95.9/43.5 95.9/43.5 95.9/43.5 95.9/43.5
Approx. Ship Weight 79.4/36 101.4/46 101.4/46 101.4/46 101.4/46

Double Conversion "On-Line" vs. Line-Interactive Technology


Double Conversion
Double Conversion "On-Line"
“Online” vs. Line-Interactive
vs. Line-Interactive Technology Technology
Double Conversion is the most popular UPS for high-end equipment installations due to its high quality
Double
A Conversion
Double Conversion UPSisisthe
and reliability. mostpopular
the most popular UPS forequipment
for high-end high-end equipment
installations due installations
qualitydue
to its high quality andto its high
reliability.
and reliability.
BUCK & BOOST BYPASS
RELAY CONTACTOR
BUCK & BOOST OUTPUT BYPASS
RELAY POWER
OUTPUT
CONTACTOR
STATIC
POWER
STATIC BYPASS
BYPASS BYPASS SWITCH
FUSE
BYPASS SWITCH
EMI / SURGE FUSE
INPUT
POWER SUPPRESSION
INPUT EMI / SURGE
SUPPRESSION ANTI
POWER
ANTI
BACKFEED RECTIFIER INVERTER
CONTACTOR
BACKFEED
INPUT
RECTIFIER INVERTER
CONTACTOR OUTPUT
CIRCUIT
CIRCUIT
INPUT BREAKER
EMI / SURGE
OUTPUT BREAKER
CIRCUIT AC
SUPPRESSION CIRCUIT
BREAKERINPUT
BATTERY INVERTER EMI / SURGE
BREAKER
AC
CHARGER SUPPRESSION
BATTERY INVERTER INPUT
CHARGER

BATTERY CHARGER
BATTERY CHARGER
BATTERY
BATTERY
Alpha Pinnacle Plus

Pinnacle Plus Advantages

Advanced Digital Signal Processing Technology (DSP)


Capable of monitoring all conditions of the UPS in real time and creating a pure sine wave output with
1% regulation.

Designed for Continuous Battery Operation


Highly effective power module – Insulated gate bipolar transistor (IGBT) with greater current rating, durability and
zero transfer time to prevent any load interruption.

User Friendly Smart LCD Display


All models have an interface to clearly indicate UPS status such as normal operations of batteries, bypass,
fault, recharge, load, load size and capacity.

Unique Battery Management


Allows for the addition of battery packs to prepare for extreme power outages.

Automatic Frequency Synchronization


UPS can be selected for 1 or 3Hz to operate on back-up generator power while the power supply stabilizes
the frequency without any interruptions to the load.

Internal Static Bypass


Under special circumstances such as overload, protection or crash, the UPS will automatically switch to
main power using an internal bypass circuit.

Self-Diagnostic Function
Once the UPS is powered on, the unit automatically monitors for fault conditions, protects itself and
the load from any of the these conditions and displays a comprehensive error code.

All Pinnacle Models Include AlphaMON Shut Down Software


Software includes UPS utility monitoring, scheduled system shutdown with file saving
capability, warning notification via e-mail and pager, and user-definable warnings.

Optional Internal SNMP/Web Agent


SNMP/Web Agent has a system administrator notification, java applets, automatic
shutdown, multi-server shutdown, enhanced HTTP security, and a new Graphical
User Interface (GUI) for the systems ‘s home page and applets.

User Accessible Hot Swappable Batteries


The Pinnacle Plus series is designed with an easily accessible hot swappable
battery that eliminates sparks and ensures user safety.

For more information visit: www.alpha.com

Alpha Technologies Toll free: 1 800 667 8743 Direct: 604 430 1476 #049-032-10-007 (03/09)

Due to continuous product improvement and modifications, Alpha Technologies reserves the right to make changes to the products and information contained in this
document without notice. Copyright © 2009 Alpha Technologies. All Rights Reserved. Alpha® is a registered trademark of Alpha Technologies. Member of The Alpha
Group™ is a trademark of Alpha Technologies.

You might also like