Product data sheet XPSMCMRO0004
Characteristics expansion module, Modicon MCM, 4 safety
relay outputs, with backplane connection,
screw
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Main
Range of product Preventa Safety automation
Product or component type Safe relay output module
Device short name XPSMCM
Electrical connection Screw terminal
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
[Us] rated supply voltage 24 V - 20...20 % DC
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
Number of outputs 4 relay
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Discrete output number 8 solid state at 125 mA (diagnostics)
Function of module Monitoring safety actuators for relay output
Complementary
Maximum power dissipation in W 3W
Integrated connection type Backplane expansion bus
Switching voltage 10 V DC
Associated fuse rating 3.5 A, slow-blow
Safety level Can reach category 4 conforming to EN/ISO 13849-1
Can reach PL = e conforming to EN/ISO 13849-1
Can reach SIL 3 conforming to EN/IEC 61508
SILCL 3 conforming to IEC 62061
Quality labels CE
Output type Relay, 4 NO circuit(s), volt-free
Quantity per set 1
Switching time 12 ms
Maximum switching voltage 400 V AC
250 V DC
Minimum switching current 20 MA
Maximum switching current 6A
Number of terminal blocks 4
Local signalling 1 LED green with PWR marking for power ON
1 LED green with RUN marking for RUN (status)
1 LED red with E IN marking for internal error
1 LED red with E EX marking for external error
2 LEDs orange with ADDR marking for node address
4 LEDs green/red with RELAY K1...K4 marking for relay contact
4 LEDs yellow with RST marking for reset
Connections - terminals 2 captive screw clamp terminals, removable terminal block
1 captive screw clamp terminals, removable terminal block
Jul 27, 2023
1
Cable cross section 0.2…1.5 Mm² - AWG 24...AWG 16 flexible cablewithout cable end
0.2…2.5 Mm² - AWG 24...AWG 14 flexible cablewithout cable end
0.25…1 Mm² - AWG 23...AWG 18 flexible cablewith cable end, without bezel
0.25…2.5 Mm² - AWG 23...AWG 14 flexible cablewith cable end, with bezel
0.25…2.5 Mm² - AWG 23...AWG 14 flexible cablewith cable end, without bezel
0.5…1.5 Mm² - AWG 20...AWG 16 flexible cablewith cable end, with double bezel
0.2…1 Mm² - AWG 24...AWG 18 solid cablewithout cable end
0.2…2.5 Mm² - AWG 24...AWG 14 solid cablewithout cable end
Mounting support Omega 35 mm DIN rail conforming to EN 50022
Width 22.5 Mm
Height 99 Mm
Depth 114.5 Mm
Product weight 0.3 Kg
Environment
Standards IEC 62061
EN/ISO 13849-1
EN/IEC 61800-5-1
EN/IEC 61508
Product certifications TÜV
RCM
cULus
IP degree of protection IP20
Ambient air temperature for operation -10…55 °C
Ambient air temperature for storage -20…85 °C
Relative humidity 10…95 %
Pollution degree 2
[Uimp] rated impulse withstand voltage 4 KV conforming to EN/IEC 61800-5-1
Safety reliability data B10d = 300000 utilisation category AC-15 230 V, , <3 A conforming-
to EN/ISO 13849-1
B10d = 750000 utilisation category AC-15 230 V, , <1 A conforming-
to EN/ISO 13849-1
B10d = 10000000 utilisation category DC-13 24 V, , <2 A conforming-
to EN/ISO 13849-1
Insulation 250 V AC between power supply and housing conforming to EN/IEC 61800-5-1
Overvoltage category II
Electromagnetic compatibility Electrostatic discharge immunity test - test level: 6 kV (on contact) conforming-
to EN/IEC 61000-4-2
Electrostatic discharge immunity test - test level: 20 kV (on air) conforming-
to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) con-
forming to EN/IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) con-
forming to EN/IEC 61000-4-3
Vibration resistance +/-0.35 mm (f= 10…55 Hz) conforming to EN/IEC 61496-1
Shock resistance 10 gn for 16 ms (1000 shocks on each axis) conforming to EN/IEC 61496-1
Electrical durability 20000000 Cycles
Mechanical durability 20000000 Cycles
Service life 20 Year(S)
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 4.2 Cm
Package 1 Width 12.5 Cm
Package 1 Length 16.1 Cm
Package 1 Weight 294.0 G
Unit Type of Package 2 S01
Number of Units in Package 2 6
Package 2 Height 15.0 Cm
Package 2 Width 15.0 Cm
Package 2 Length 40.0 Cm
Package 2 Weight 1.991 Kg
2
Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
REACh free of SVHC Yes
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Decla-
ration
Mercury free Yes
China RoHS Regulation
China RoHS Declaration
RoHS exemption information
Yes
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End Of Life Information
WEEE The product must be disposed on European Union markets following speci-
fic waste collection and never end up in rubbish bins
PVC free Yes
California proposition 65 WARNING: This product can expose you to chemicals including: Lead and-
lead compounds, which is known to the State of California to cause can-
cer and birth defects or other reproductive harm. For more information go-
to www.P65Warnings.ca.gov
Product Life Status : Commercialised