br-ups-vfi-rt+

The VFI-RT+ UPS offers advanced power protection with true online double conversion technology, available in 1.5KVA and 3KVA capacities. It features a compact design suitable for rack or tower mounting, adjustable output voltage, and high efficiency, reducing operational costs. Additional battery packs can be added for extended runtime, and it includes comprehensive communication options, including SNMP and USB interfaces.

Uploaded by

Ford Prefect
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
31 views4 pages

br-ups-vfi-rt+

The VFI-RT+ UPS offers advanced power protection with true online double conversion technology, available in 1.5KVA and 3KVA capacities. It features a compact design suitable for rack or tower mounting, adjustable output voltage, and high efficiency, reducing operational costs. Additional battery packs can be added for extended runtime, and it includes comprehensive communication options, including SNMP and USB interfaces.

Uploaded by

Ford Prefect
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

VFI-RT+ UPS

Extra Features
Rack / Tower
Online Double Conversion

■ Available 1.5 & 3KVA The VFI-RT+ Uninterruptible Power Supplies are the benchmark in power
protection performance. True online double conversion technology
■ VFI Technology provides the highest degrees of power protection making the UPS
suitable for a wide variety of mission critical equipment and infrastructure.
■ Matching Battery Cabs
The VFI-RT+ can be mounted in a 19” rack installation and occupies only
■ High Capacity Charger 2U of rackspace. Alternatively, the unit can be vertically mounted with the
supplied support brackets.
■ Adjustable Charge Current
The high output power factor of 0.9 removes the risk of overload on
■ Adjustable Output Voltage power factor corrected loads. The high efficiency of the VFI-RT+ reduces
the need for additional cooling requirements, reducing operating costs
■ Frequency Conversion
and can be set into even higher efficiency ECO mode operation if
Mode required.

■ Intelligent
Port for SNMP / Additional battery packs can be added to extend runtime with the added
Relay Options benefit of built-in high capacity chargers, allowing large battery strings to
be recharged in a timely fashion. These can be added at a later date as
■ Rack/Tower Format and when required. Internal UPS batteries and those of matching cabinets
can be hot-swapped during the UPS life for ease of maintenance.
■ Programmable Outlets
To improve reliability and protect against environmental contaminants
■ Hot Swap Battery such as moisture and dust, the PCB boards have been conformally coated.

■ HID USB Interface Full HID Compliant USB interface for connection directly to operating
system power management, with capability of SNMP / Relay for added
■ Conformally Coated PCB communication options.
Online Double Conversion Topology Protects Against the 9 Recognised Power Quality Problems
 Blackouts  Sags  Spikes  Under Volts  Over Volts  Noise  Frequency  Transients  Harmonics

Rear Panel Configuration & Description

❶ Programmable Outlets. Can be


configured to shut off when on battery after
set time.
❷ Output Receptacles. Non Programmable.
❸ Input Receptacle
❹ Network Surge Protection
❺ HID Compliant USB Port
❻ RS232 Interface
❼ Intelligent Slot for Relay/SNMP
❽ Emergency Power Off (EPO) Connector
❾ External Battery Connection Port

UPS LCD and Parameter Settings

The comprehensive LCD provides at a


glance battery and load level bars. The
UPS status is provided in a easy to read
graphical display.

The UPS can be interrogated to show


input voltage and frequency, output volt-
age and frequency, battery voltage and
charge percentage. In battery mode the
remaining battery time or on battery
time is displayed.

The LCD can be rotated depending upon


rack or tower use and is also used for
setting UPS parameters:

■ Output voltage to 208/220/230 or 240V. ■ Setting the total attached battery capacity, the UPS
■ Frequency Converter Mode and Output Frequency of charge current and boost and float voltages if
50 or 60Hz. required.
■ ECO mode enable / disable and adjustable revert to
■ EPO polarity input. Activate emergency power off
online voltage points.
on normally closed (default) or normally open
■ Bypass enable / disable and adjustable voltage and contact.
frequency levels.
■ Set for output isolation transformer which will alter
■ Programmable outlets and setting time from 0-999 UPS output dependent on load to account for
minutes after battery operation when outlets will shut transformer regulation.
off.
■ Setting the display to show estimated time
■ Autonomy time management. None, or limit to a set remaining on battery, or time on battery.
value to prevent a deep discharge or preserve battery
■ Adjusting input voltage parameters before UPS
status.
reverts to battery operation.
Batteries and External Battery Cabs

The VFI-RT+ contains an internal battery tray and an adjustable, high capacity charger. This allows the unit to be used in
standard runtime configurations, but also allows the addition of further battery packs without the need to either specify
an extended run UPS in the first instance, or provide additional chargers. Each cab is matching in appearance, 2U
rackmount or vertical standing, and can be hot-swapped.

Adjustable charging currents from


1A to 12A on the 1500VA and 1A
to 8A on the 3KVA are standard.

Each battery cabinet can be daisy chained to the next cab to provide extendable runtime. The provided cable in each
cab connects to the UPS or the next cabinet. Each cab is complete with a circuit breaker for protection and isolation.

The UPS internal batteries as well


as the cabinet batteries are
contained within self contained
trays and are fully hot-swappable.

Each cab contains 2 trays


consisting of 9Ah blocks meaning
each cab adds 18Ah to the
battery capacity.

The cab comes with vertical


support extenders that mate with
the UPS brackets to allow for
vertical configuration.

Communications

The USB port provides full serial communications to an


attached computer. Being HID compliant the unit will
“talk” to the operating system directly (effectively
making a desktop like a laptop in terms of power
operation). Alternatively, shutdown software can be
downloaded and installed.

Legacy RS232 is also available.

The rear panel includes an


“intelligent slot” for the
addition of either an SNMP or
an AS400 relay card. SNMP
allows monitoring of the UPS
over a network connection. The
advanced card also contains an
event log. The relay card allows
connection to AS400 servers or
any other remote alarm or
Building Management Systems.
SPECIFICATIONS
MODEL VFI1500RT+ VFI3000RT+
INPUT
Capacity 1500 VA /1350 W 3000 VA / 2700 W
160 VAC / 140 VAC / 120 VAC / 110 VAC ± 3 % (80Vac/70Vac/60Vac/55Vac ± 3%)
Low Line Transfer
based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0
Voltage Range Low Line Comeback 175 VAC / 155 VAC / 135 VAC / 125 VAC ± 3 %
High Line Transfer 300 VAC ± 3%
High Line Comeback 290 VAC ± 3%

Frequency Range 40Hz ~ 70Hz

Phase Single phase with ground


Power Factor ≧ 0.99
THDi ≦5%
OUTPUT
Voltage 200*/208*/220/230/240 VAC
Voltage Regulation ± 1%
Frequency Range (Synchronized Range) 50Hz system: 47 ~ 53 Hz (60Hz system:57~63Hz)
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz (60Hz ± 0.1 Hz)
Current Crest Ratio 3:1
≦ 2 % THD (Linear Load)
Harmonic Distortion
≦ 4 % THD (Non-linear Load)
AC to DC Zero
Transfer Time Inverter to Bypass 4 ms (Typical)
ECO to Battery mode 8 ms (Typical), 10 ms(max)
Waveform (Batt. Mode) Pure Sinewave

100% < Load < 110% Overload warning only


110% < Load < 130% (-0%/+10%) 5min (+/- 4sec) @ Ambient temperature < 40°C or 2.5min(+/- 4sec) @
On-line Mode Ambient temperature >= 40°C.
130% < Load < 140% (-0%/+10%) 30sec (+/- 1sec)
140% < Load (-0%/+10%) 1.5sec (+/- 0.5sec).
Over Load
Capacity
100% < Load < 110% Overload warning only
110% < Load < 130% (-0%/+10%) 2min (+/- 4sec) @ Ambient temperature < 40°C or 1min(+/- 4sec) @
Inverter(Battery) Mode Ambient temperature >= 40°C.
130% < Load < 140% (-0%/+10%) 10sec (+/- 1sec)
140% < Load (-0%/+10%) 1.5sec (+/- 0.5sec).

EFFICIENCY
ECO mode ≧96% @ full charged battery
AC Mode ≧89% @ full charged battery ≧91% @ full charged battery
Battery Mode ≧88% @ full load ≧90% @ full load
BATTERY
Battery Type 12 V / 9 AH 12 V / 9 AH
Numbers 3 6
Typical Recharge Time 2.5 hours recover to 95% capacity of battery(if 3A chargering current)
Charging Current (CC) 1/2/3/4/6/8/10/12A Selectable 1/2/3/4/6/8A Selectable
Charging Voltage(FV) 41.1VDC ± 1% 82.2VDC ± 1%
INDICATORS

Status Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicator Via LCD

ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continously sounding
PHYSICAL
Dimension, D X W X H (mm) 410 x 438 x 88 630 x 438 x 88
Net Weight (kgs) 15.5 27.5
ENVIRONMENT
Humidity 20-95 % RH @ 0- 45°C (non-condensing)
Noise Level Less than 50dBA @ 1 Meter with Fan speed control
MANAGEMENT
Smart RS-232 Supports Windows 98 SE/ME/NT 4.x/2000/2003/XP/Vista/2008/7/8/10, Linux, MAC.
USB HID Compliant USB

Optional external Slot (for SNMP, Dry contact, …) Power management from SNMP manager and web browser

*Derate capacity to 80% when the output voltage is adjusted to 200VAC/208VAC.

Power Inspired Ltd. Unit 122 Churchill Road, Bicester, Oxfordshire, OX26 4XD, UK.
T: +44 1869 814055; W: www.powerinspired.com; E: [email protected]
Although every effort is made to ensure accuracy of this document, information is provided for guidance only and does not form part of any contract.
Specifications are subject to change without notice.