The Power/eNavigator is an advanced power analyser designed for efficient energy management, offering features such as true RMS measurement, data logging, and dynamic communication. It allows users to monitor and control electrical systems, track demand, and manage power quality while providing protection against electrical abnormalities. With customizable options and compliance with safety standards, it serves as a comprehensive solution for various electrical monitoring needs.

Uploaded by

G Paramasivam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views4 pages

pc_eNavigator EN8410

The Power/eNavigator is an advanced power analyser designed for efficient energy management, offering features such as true RMS measurement, data logging, and dynamic communication. It allows users to monitor and control electrical systems, track demand, and manage power quality while providing protection against electrical abnormalities. With customizable options and compliance with safety standards, it serves as a comprehensive solution for various electrical monitoring needs.

Uploaded by

G Paramasivam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

HIGH PROFILE POWER ANALYSER

Load Manager, Data Logger, Dynamic Communication

POWER NAVIGATOR eNAVIGATOR

Power/eNavigator, a sophiscated Power Analyser that enables the user to navigate the full scope of an electrical
network and empowers to manage power efficiently. The instrument offers versatile and unmatched features and
functions to monitor, profile, record events, control, data logging, protect and even check the quality of an
electrical system. Power/ eNavigator is built to be a single point solution to meet your energy management needs.

www.elmeasure.com
alog
2 An
Common Features Optional Features Upto utput
O
l True RMS measurement l Digital outputs 4 potential free contacts
l Simultaneous sampling of Volts & Amps with programmable time delay. Hysteresis 1%.
l High / low recording - V, A, Hz, W, VA, PF, VAr value storage Trip time 1 to 80 sec. Programmable
l Accuracy class 1.0 IEC 61036 / CBIP 88 (0.5 option) l Analog Output - Two independently programmable to
l User programmable Password Protection 0-20 mA (or) 4-20 mA output, configurable to any VLL, A,
l Auto-Scaling of Kilo, Mega and Giga decimal point F, W, PF, VA parameters
l Neutral Current (calculated) and RPM display
l Individual Harmonics upto 31st level for V & A
l Clearance and creepage distance meets IEC61010 safety standard
l Datalogger - 1MB / 8MB optional (refer table 1)
l Programmable starting current in % of 5A secondary. Default 0.4%
l Selectable VA measurement Vector/Arithmetic/Vector harmonics l Dual port communication
l K-Factor V & A (all three phase) l Demand updation @ 1 sec
l Programmable parameter update rate 1sec. to 5sec. (Default 1sec.) l Demand Controller with 1 Relay, 2 Relay & 4 Relay
l Programmable Auto scrolling time 1 sec. to 10 sec. (Default 5 sec.) outputs.
l Pulse output (POP) on time 50-500 mS user programmable l RTC can be adjusted using external communication
l Dynamic communication - user selectable register map upto 60A direct measurements using Hanging CT
l Programmable - Energy display counter based or resolution base
l Energy resetting @ 999999 kWh × Multiplication factor
l Reverse lock option user programmable for positive energy accumulation Added Features in Power Navigator
l Front LED pulse 5000 imp/kWh
l % of unbalance V & A for all the phases l Phase wise Voltage & Current Wave Forms
l THD for Voltage and Current (upto 31st) l LCD 7 parameter display at a time, 7 digit energy value
l Ampere hour (Ah) and PF average parameters l Wave form communication through ELAudit Software
l Upgradable to higher versions l Power save mode with Enable/Disable option
PN7700 PN7700LM PN7710 PN7710DMC
Features Parameters EN8400 EN8400LM EN8410 EN8410DMC
Features Parameters PN 7700 PN 7700 LM PN 7710 PN 7710 DMC
Basic
Line to Neutral Voltage VLN Avg,VR-N,VY-N,VB-N
Line to Line Voltage VLL Avg,VR-Y,VY-B,VB-R
Line Current A, AR, AY, AB, Avg
Neutral Current Computed AN
Frequency, RPM (Generator application) Hz, RPM
V & A Phase Angle VR, VY, VB, AR, AY, AB
Unbalance V & A % V, % A, VR, VY, VB, AR, AY, AB
Power
Active Power W Total, WR, WY, WB
Apparent Power VA Total, VAR, VAY, VAB VA Tot
Reactive Power VAr Total, VAr R, VAr Y, VAr B VAR Tot
Power Factor PF Avg, PFR, PFY, PFB
Energy / Integrated
Active Energy (Wh) Wh
Apparent Energy (VAh) VAh
Reactive Energy (Varh), Ah, PF Avg VArh-Ind, VArh-Cap, Ontime Ah, PF Avg
Load Hrs, No. of Interruption, Life Timer LH, Intr, Life count
Old (Energy, Load Hrs) Old (Wh, VAh, VArh Ind/Cap, LH)
Harmonics
Voltage THD THD% VR, VY, VB
Current THD THD% AR, AY, AB
K Factor K Factor: VR, VY, VB, AR, AY, AB
Events (High/Low)
Voltage VLL, VLN High/Low VLL, VLN
Current High/Low A
Frequency High/Low Hz
VA High/Low VA
W High/Low W
VAr High/Low VAr
Power Factor High/Low PF
Demand (Optional) Programmable to any one of the below

}
Active Power (W) Watt Sliding Sliding RTC RTC
Programmable sliding/
Apparent Power (VA) VA fixed window, demand 1 relay window Based Based
Reactive Power (VAr) VAr period, forcast/step 2 relay 4 relay
Current Average (A.Avg) A Avg demand control
Control Features (Optional) Programmable
Digital Output (Up to 4 relay) Under/over (VLL, A, Hz) Over (W, VA, Wh) Under (PF),
Tripping time (1-180 sec) Phase rev, Single Phase, Analog I/p1, Analog I/p2
Analog Output / Analog Input Up to 2
Special Features (Optional)
Data Logging with Time stamp (1MB/8MB Optional) Refer Table 1
Received/Delivered (Import/Export) Wh, VAh, VArh Ind/Cap, PF.Avg, Ah, Lh Wh, VAh
40A Direct measurement 3 Phase (Hanging CT)
Individual Harmonics V & A upto 31st Harmonics
Communication (Optional)
RS-485 or RS-232 (MODBUS) RS 232 / RS 485
Default Optional feature - no restriction on combination of options
LM : Load Manager
Restricted optional feature - Combination of all restricted options may not be possible in a single product DMC : Demand Controller

[email protected]
EN 8499 l Displays all energy (Wh, VAh or VArh Inductive, Capacitive) parameters
l Received / Delivered (Import/Export) Energy option
l Separate Load hours for received, delivered and net
l OLD register to store previously cleared energy values and load hours
l Pulse output - Programmable pulse width of 50 mS to 500 mS (Optional)
l RS 485/232 Optional
Note: This model can be customized for any parameters available in EN 8400LM

Key Unique Features


Demand Management Harmonics up to 31st level and THD
Monitoring - helps to visualise of the demand profile during a Presence of THD will urge the user to identify the polluting loads
billing cycle. Demand peaks with date & time can be identified and take necessary action to mitigate harmonics thru' an
in the meter as well as ElMeasure's ElNet software. The events appropriate harmonic filter and save energy and also to improve
can be studied and related with the production events such as plant & equipments efficiency.
starting of furnace or a large motor etc., and helps to decide on
switching/staggering of loads etc.
Control - Enables user to program the threshold values of max
demand and initiate ALARM/ CUT-OFF when the Forecast
Demand/ Present Demand/ Max Demand surpasses the
threshold values. This will help the user from exceeding the
sanctioned demand and avoid causing a trip or paying huge
penalty.
Monitors Basic, Power & Energy Parameters
Additional Load - By this feature the user shall be able to decide
to transfer the exact quantum of load from EB to DG or vice Provides the complete spectrum of Electrical system and help
versa for economic power. study of load pattern.

High Low Event Recording for V, A, Hz, VA, W, VAr, PF Process Integration
Protection of 3 phase system against single phasing, low & high Integration of process parameters such as temperature, Oil level,
voltage, over load, highly lagging and leading PF, Hz etc. Power RPM, Pressure etc. giving greater flexibility to monitor them
Navigator can trap such events for future reference. along with electrical parameters.

VLL
VA
W

Identify & record unbalance voltage and currents and helps the Control Features
user to identify the root cause. Unbalance over-burdens the 4 user defined potential free Digital Output based on threshold
electrical system and affects in the form of over loading of setting for protection relay for any of Under/Over VLL, A, Hz
cables, motors and switchgear. Over (W, VA, Wh) Under (PF), Phase reversal, Single Phase, with
PF Management programmable trip time to protect the equipments from
electrical abnormalities.
Lower the Avg PF higher the system inefficiency. So this enables
the user to maintain a healthy PF level. The Digital output Power Quality Check/Management
features can be used to initiate alarm when the Avg PF crosses Monitoring phase angle will help the user to identify the causes
the user programmed threshold values (Lead/ Lag). such as deterioration in the distribution transformers, cables &
cable termination, presence of harmonics etc.
Data Logging with Time Stamp
The information is needed in all types of businesses to Cross Verification of Electricity Billing
determine performance, quality, efficiency, cost reduction, fuel Power Navigator will help the user to cross verify with the tariff
consumption monitoring and many other critical factors. This meter and initiate suitable action if the values have a wide
feature provides important and accurate data for analysis. disparity.

Energy Display programmable for counter based or Resolution based Table 1


No of No of Records
Parameters 1MB 8MB
Multiplication factor for counter based energy mode 1 121920 982080
Full Scale kW 0.4 4.01 40.1 400.1 4Mega 40 M 400 M nal 2 81280 654720
Optio able
3 V Pri LL x A Pri / 1000 to to to to to to to ram m 4 48768 392839
4.0 40 400 4,000 40 M 400 M 4000 M Prog Logging
Data 9 24384 196416
0.01 0.1 1.0 10 100 1000 10000 14 16256 130944
Multiplication Factor:
29 8128 65472
Unit of display KWH MWH GWH
1 Minute to 12 hours interval programmable. Data
interval and parameter can be selected through
Energy Reset : 999999 kWh × Multiplication Factor
RS485 communication.
www.elmeasure.com
Digital Outputs : (Up to 4 relay Outputs) Typical Applications
* 4 User defined potential free relay outputs based on threshold Automatic connection or disconnection of Gensets
setting. connected to common bus

* Protection relay for any of Under/Over VLL, A, Hz Over Protection of equipment from Under/ Over Voltage or
(W, VA, Wh) Under (PF), Phase reversal, Single Phase. Current or Frequency
* Programmable trip time 1 to 180 sec to suit different load conditions
Protection of 3 phase equipment from Single phase
* Rating of control relays: NO contact SPST. prevention, Over load etc.
250 VAC / 30 VDC @ 2 Amps resistive

18 Months
Safety and Environment Specifications Technical Specification Warranty

Safety Accuracy: Class 1 (Default) IEC 61036, IS 13779, CBIP 88


Designed to meet protection class III, pollution degree 2. Class 0.5, 0.5S (Option)
Protection against shock by double insulation. Sensing/Measurement: True RMS, 1 Sec update time.
Clearance and creepage meets UL 508 safety standard. 4 Quadrant Power & Energy (RD Option)
Finger touch proof terminals to voltage and current connections.
Input voltage: 4 Voltage inputs (VR, VY, VB, VN)
Environment Programmable 110 or 415V LL Nominal
Operating temperature -10°C to +55°C (14°F to 131°F) (Range 80 to 550V LL)
Storage temperature -25°C to +70°C (-13°F to 158°F) Primary Programmable up to 999 kV.
Humidity 5% to 95% non condensing. Burden: 0.2VA Max. per phase
Input current: Current inputs (AR, AY, AB) 50mA - 6A
Protection index IP 51 (IP 54 front option) (Field configurable 1A or 5A).
Recommended connecting wire 12 to 14 SWG with U type lug of
Primary Programmable up to 99 kA.
6.75 mm width max.
Overload: 10A max continuous, 50A max for 3 Sec
ECO Friendly Burden: 0.2VA Max. per phase.
Lead Free
Aux-Supply (Control Power)
Standards Applicable 80 - 300V AC/DC, 40-70Hz, 48V DC (optional)
Test of insulation properties IEC 60060-1 Burden: 4VA Max
Test of Accuracy requirements IEC 62052-11 Display Type:
eNavigator: 10mm height bright red LED display
Test of electrical requirements IEC 62052-11
Power Navigator: 6mm height bright LCD graphical display
Radio interference suppression CISPR 22
Display Resolution: 4 digits for instantaneous,
Fast transient burst test IEC 61000-4.4
Integrated: EN - 6 digits, PN - 7 digits
Damped oscillatory waves immunity test IEC 61000-4.12
CT PT Ratio Max: 2000 MVA Programmable
Test of immunity to electromagnetic RF fields IEC 61000-4.3
Communication:
Test of immunity to conducted disturbances, IEC 61000-4.6 RS485 serial channel connection, Industry standard
induced by radio-frequency fields
Modbus RTU protocol (RS232 optional).
Test of immunity to electrostatic discharges IEC 61000-4.2 Baud rate: 2400 bps to 19200 bps. (Preferred 9600 bps)
Surge immunity test IEC 61000-4.5 Isolation: 2000 volts AC isolation for 1 minute between
Test of the effect of the climatic environments IEC 60068-2 communication and other circuits.
Mechanical tests IEC 60068-2 Weight:
Test of protection against penetration of dust IEC 60529 Unpacked: 300 gms
and water Packed: 400 gms
Test of resistance to heat and fire IEC 60695-2
Note: Additional error of 0.05% of full scale,
for meter input current below 500mA

Mechanical Specification
Dimension Bezel : 96 x 96 mm (Depth 50mm behind Bezel)
ELECON MEASUREMENTS PVT LTD Panel Cutout : 92-2+0 x 92-2+0 mm
Empowers Yo u to Manage Power
A group of ELMEASURE INDIA PVT LTD 92 mm
HO & Unit-I # 764, 4th Phase, 707, Yelahanka New Town, Bangalore - 560 106. INDIA
PC/NAV/V1/0911

T : +91 80 2846 1777/744 F : +91 80 41272461


92 mm

CS : +91 80 3290 4489 E : [email protected]


Unit-II Goutham Garden, No. 4, Veerapandi, Coimbatore - 641019 INDIA
T : 0422 2697200. TF : 0422 2695200 E : [email protected]
Unit-III Plot No.: 323/19, Camp Road, Selaqi, Dehradun, UTTARANCHAL
C : 097600 02492, 12492 E : [email protected]

Sales Offices: BANGALORE | MUMBAI | DELHI | HYDERABAD | USA | UAE | MALAYSIA


Range of Products: EMS, Demand Controller, Multi-function Meters, Load Manager, Electronic Energy Meters, Dual Energy Meter,
Digital Panel Meters, Power Factor Controller, Intelligent Earth Leakage Relay, Power Distribution Unit,
Power & Energy Transducers, RS485 to RS232/Ethernet/Optic Fiber Converter, RF Modem and GSM Modem

You might also like