Leroy Somer FLSLB
Leroy Somer FLSLB
General information
Totally enclosed slip ring, wound rotor to start. A rheostat is used in order to start a
three-phase asynchronous motors. motor.
Power from 7.5 to 300 kW for the frame sizes
taking values from 160 to 355 mm. Leroy-Somer recommends the liquid
Voltage: 230 V Δ / 400 V Υ, 50 Hz (other resistance rheostat known as the Polystart
voltages and frequencies on request). electrolytic starter.
Insulation class F, overheating B. This type of starter inserts a resistance into
Standard version IP 55. the rotor circuit, which gradually reduces until
it disappears completely by a short-circuit at
Performances the end of the starting period.
Thanks to the insertion of an appropriate The technical description «Transient
rheostat in the rotor circuit, the slip ring, operation - Starters».
wound rotor motor offers the following Caution, the Polystart is not suitable for
possibilities: hoisting applications.
- adapting the motor torque to that of the
driven machine; Use conditions
- tolerant of long starts; In the selection grids the following values are
- limits the starting current; indicated:
- sets the speed of rotation with the aid of a - for a general use in service S3 (series
permanent slip rheostat (consult our technical FLSB);
department for this application). - for a hoisting and handling S4/S5 (series
Starting FLSLB).
The slip ring, wound rotor motor does not
depend on the stator being connected in order
Wound rotor - winding enamel covered wire, shrunk fibreglass on steel ring
- dynamically balanced rotor, class A - 1/2 key
Labyrinth seals Steel or synthetic rubber - front and rear lipseal for frame sizes from 160 to 200 included
Lipseals - front and rear decompression grooves from 225 to 250
- front and rear labyrinth seals for frame sizes ≥ 280
Fan Composite material up to 200 included, - 2 directions of rotation: straight blades
metal thereafter
Fan cover Hardened pressed steel up to 250 inclusive, - on request, fitted with a drip cover for operation in vertical position, shaft facing down
in cast iron thereafter
Stator terminal box Cast iron - IP 55
- fitted with a 6 or 9 terminals board
- from 160 to 355, closing plate fitted with brass cable glands
- 1 earth terminal in all terminal boxes
Rotor terminal box Cast iron from 280 only Connection to slip ring provided:
- for types 160: directly on a commutator bearing via a supplied cable gland (1 PG 21
brass)
- for types 180 to 200: directly on a commutator bearing via a supplied cable gland (1 PG 29
brass)
- for types 225 to 250: directly on the brush holders via a supplied cable gland (1 CM 30 L)
- for types 280 to 355: in an additional terminal box located on the rear bearing
housing
A7.1
FLSB - FLSLB slip ring
totally enclosed three-phase asynchronous motors
Mounting positions
Foot mounted motors
IM 1001 (IM B3 IM 1051 (IM B6) IM 1061 (IM B7) IM 1071 (IM B8) IM 1011 (IM V5) IM 1031 (IM V6)
IM 3001 (IM B5) IM 3011 (IM V1) IM 3031 (IM V3) IM 2001 (IM B35) IM 2011 (IM V15) IM 2031 (IM V36)
4
3 1
2*
A : standard 1 : standard
* Position 2 not recommended and not feasible
on plain hole standard flange motor (FF)
Code II IM 1001 IM 3001 IM 1051 IM 1061 IM 1071 IM 2001 IM 3011 IM 3031 IM 1011 IM 1031 IM 2011 IM 2031
Frame
size
160 l l l l l l l l l l l l
180 l l l l l l l l l l l l
200 l l l l l l l l l l l l
225 l o m m m l l l m m m m
250 l o m m m l l l m m m m
280 l o m m m l l l m m m m
315 l o m m m l l m m m m m
355 l o m m m l l m m m m m
l : Possible positions
o : Non possible positions
m : Consult us, specifying the connection method and the possible radial and axial loads
A7.2
FLSB - FLSLB slip ring
totally enclosed three-phase asynchronous motors
Adaptation possibilities
Leroy-Somer offers, in association with the FLSB-FLSLB slip ring motors, many options described
above in the chapter relating to the transient system.
For other variants or all special adaptation, consult the technical specialists at Leroy-Somer.
Electrolytic starter
(FF) plain holes POLYSTART
flange mounted motor
thermal protections:
PTO
PTF
Designation / Codification
4P IM 1001 230 /
FLSB 200 L 22 kW 50 Hz IP 55
1500 min-1 (IM B3) 400 V
+ Codification example:
Slip ring motor FLSB 1500 min-1, 22 kW
IM 1001 (IM B3), 230/400 V The table above is an example.
Designation Code It allows the creation of the designation for the required product.
4P FLSB 200 L 22 kW This designation corresponds to a product code.
IM 1001 (IM B3) MA4 22 307 The product codes that are present in the selection grids can be used directly.
230/400 V - 50 Hz They simplify the ordering process.
The codification table is incorporated in the price list with the designations list.
A7.3
FLSB - FLSLB slip ring
totally enclosed three-phase asynchronous motors
Selection
Hoisting and handling use - S4 or S5 duty
pole
6 IP 55 - 50 Hz - Class F - 230 V Δ / 400 V Υ
1000 s
min -1
A7.12
FLSB - FLSLB slip ring
totally enclosed three-phase asynchronous motors
Dimensions
Dimensions of the FLSB-FLSLB totally enclosed three-phase asynchronous motors - IP 55
Slip ring -wound rotor
Dimensions in millimetres
– bout
shaftd’arbre
end
EA E
M.OA x pA M.O x p
FA
F
DA
D
GF GB GD G
Shaft ends
4 and more poles
F GD D G E O p
Type FA GF DA GB EA OA pA
FLSB-FLSLB 160 M/L 12 8 42 k6 37 110 h13 16 40
FLSB-FLSLB 180 M/L 14 9 48 k6 42.5 110 h13 16 40
FLSB-FLSLB 200 L 16 10 55 m6 49 110 h13 20 42
FLSB-FLSLB 225 S/M 18 11 60 m6 53 140 h13 20 42
FLSB-FLSLB 250 M 18 11 65 m6 58 140 h13 20 42
FLSB-FLSLB 280 S/M 20 12 75 m6 67.5 140 h13 20 42
FLSB-FLSLB 315 S/M 22 14 80 m6 71 170 h13 20 42
FLSB-FLSLB 315 L 25 14 90 m6 81 170 h13 24 50
FLSB-FLSLB 355 L 28 16 100 m6 90 210 h13 24 50
IMPORTANT NOTE: in standard, the hoisting type motors (FLSLB) have a mechanical conception
identical to the general use type motors. Conformity to the standard NF C 51-157.
A7.16
FLSB - FLSLB slip ring
totally enclosed three-phase asynchronous motors
Dimensions
Dimensions of the FLSB-FLSLB totally enclosed three-phase asynchronous motors - IP 55
Slip ring -wound rotor
Dimensions in millimetres
– foot mounted LB
Z
Ø AC
I II Q J LJ
HD
HA
H
AA x
4ØK CA B C
A
AB BB
Main dimensions
Type A AB B BB C x AA K HA H AC HD LB LJ J I II Z Q CA
FLSB-FLSLB 160 M 254 328 210 248 108 20 79 14 24 160 316 418 613 111 148 79 90 - - 301
FLSB-FLSLB 160 L 254 328 254 292 108 20 79 14 24 160 316 418 657 111 148 79 90 - - 301
FLSB-FLSLB 180 M 279 331 241 319 121 20 60 14 20 180 352 472 693 74 222 115 155 - - 336
FLSB-FLSLB 180 L 279 331 279 319 121 20 60 14 20 180 352 472 693 74 222 115 155 - - 298
FLSB-FLSLB 200 L 318 370 305 355 133 25 66 18 20 200 392 509 746 77 222 115 155 - - 312
FLSB-FLSLB 225 M 356 426 311 375 149 32 80 18 27 225 540 659 930 70 352 173 210 - - 480
FLSB-FLSLB 250 M 406 476 349 413 168 32 80 22 27 250 540 681 1010 70 352 173 210 - - 503
FLSB-FLSLB 280 S 457 537 368 499 190 40 80 22 40 280 556 730 1280 68 352 173 210 787 230 725
FLSB-FLSLB 280 M 457 537 419 499 190 40 80 22 40 280 556 730 1280 68 352 173 210 787 230 674
FLSB-FLSLB 315 S 508 600 406 598 216 45 100 27 40 315 624 833 1420 68 352 173 210 878 230 804
FLSB-FLSLB 315 M 508 600 457 598 216 45 100 27 40 315 624 835 1420 70 452 217 269 878 230 753
FLSB-FLSLB 315 L 508 600 508 598 216 45 100 27 40 315 624 835 1420 70 452 217 269 878 230 702
FLSB-FLSLB 355 L 610 710 630 710 254 40 110 27 35 355 700 910 1560 61 452 217 269 1093 230 678
FLSB-FLSLB 355 L1 610 710 630 710 254 40 110 27 35 355 700 910 1685 61 452 217 269 1218 230 803
1. 4 poles motors from 250 kW at catalogue rotor voltages and 6 and 8 poles from 160 kW at catalogue rotor voltages.
A7.17