0% found this document useful (0 votes)
14 views3 pages

Quiz 3 09.11.24

The document outlines a course assessment for Power System Protection at Daffodil International University, focusing on the Merz-Price circulating current scheme for alternator protection. It includes questions on the protection of alternator windings, calculations for earth fault protection, and explanations of unbalance loading faults. Additionally, it requires illustrations of protection mechanisms and differentiations between various fault types.

Uploaded by

Mahmudul Islam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views3 pages

Quiz 3 09.11.24

The document outlines a course assessment for Power System Protection at Daffodil International University, focusing on the Merz-Price circulating current scheme for alternator protection. It includes questions on the protection of alternator windings, calculations for earth fault protection, and explanations of unbalance loading faults. Additionally, it requires illustrations of protection mechanisms and differentiations between various fault types.

Uploaded by

Mahmudul Islam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Daffodil International University

Department of Electrical & Electronic Engineering


Course Name: Power System protection
Course Code: EEE-327
Time: 20 min CT-3 (SET-A) Mark: 2+6+7

1. What is meant by “protecting 85% of alternator winding” in case of the Merz-Price circulating
current scheme protection?
2. A star-connected, 3-phase, 1B-MVA, 3D kV alternator is protected by Merz-Price circulating-current
principle with an earth resistance {r} ohm which is set to operate for fault currents not less than ABC
A. Calculate the percentage of the protected stator winding against earth fault.
Here, ABCD= Last 4 digit of your student ID.
3. What is unbalance loading fault? Illustrate the operation of Modified form of Merz-Price circulating
current protection for the protection of a 3-phase alternator with necessary diagram.

Daffodil International University


Department of Electrical & Electronic Engineering
Course Name: Power System protection
Course Code: EEE-327
Time: 20 min CT-3 (SET-A) Mark: 2+6+7

4. What is meant by “protecting 85% of alternator winding” in case of the Merz-Price circulating
current scheme protection?
5. A star-connected, 3-phase, 1B-MVA, 3D kV alternator is protected by Merz-Price circulating-current
principle with an earth resistance 1.D ohm which is set to operate for fault currents not less than
ABC A. Calculate the percentage of the protected stator winding against earth fault.
Here, ABCD= Last 4 digit of your student ID.
6. What is stator winding fault? Illustrate the operation of Modified form of Merz-Price circulating
current protection for the protection of a 3-phase alternator with necessary diagram.
Daffodil International University
Department of Electrical & Electronic Engineering
Course Name: Power System protection
Course Code: EEE-327
Time: 20 min CT-3 (SET-B) Mark: 2+6+7

1. What is function of in case of the Merz-Price circulating current scheme protection?


2. A star-connected, 3-phase, 1N-MVA, 3P kV alternator is protected by Merz-Price circulating-current
principle with an earth resistance 2.P ohm, is set to operate for fault currents which is 1N% of full
load current. Calculate the percentage of the protected stator winding against earth fault.
Here, MNOP= Last 4 digit of your student ID.
3. What is unbalance loading fault? Differentiate the protection set up for unbalance loading fault and
balance earth fault for small 3-phase alternator using necessary diagram.

Daffodil International University


Department of Electrical & Electronic Engineering
Course Name: Power System protection
Course Code: EEE-327
Time: 20 min CT-3 (SET-B) Mark: 2+6+7

1. What is function of in case of the Merz-Price circulating current scheme protection?


2. A star-connected, 3-phase, 1N-MVA, 3P kV alternator is protected by Merz-Price circulating-current
principle with an earth resistance 2.P ohm, is set to operate for fault currents which is 1N% of full
load current of the alternator. Calculate the percentage of the protected stator winding against earth
fault.
Here, MNOP= Last 4 digit of your student ID.
4. What is unbalance loading fault? Differentiate the protection set up for unbalance loading fault and
balance earth fault for small 3-phase alternator using necessary diagram.

You might also like