PGT25+G5/LM2500+G5
Highest efficiency and power in the 20–40 MW class,
with high-speed and low-speed power turbine options
Copyright 2021 Baker Hughes Company. All rights reserved. The information contained in this document is company confidential and proprietary
property of Baker Hughes and its affiliates. It is to be used only for the benefit of Baker Hughes and may not be distributed, transmitted,
reproduced, altered, or used for any purpose without the express written consent of Baker Hughes.
Industry leader in gas turbine technology
kW
Frame 9
Frame 7EA
Frame 6
Frame 5/2D
Frame 5/2E
Frame 5/2C Frame
Frame 5/1PA Aeroderivative
LMS100-PB+
Industrial
LMS100-PB
LM9000
LM6000 PF+
LM6000 PG
LM6000 PC
LM6000 PF
LM2500/PGT25+G5
LM2500/PGT25+G4
LM2500+/PGT25+
LM2500+/PGT25+ Xtend 9ppm
LM2500/PGT25
NovaLT16-2
NovaLT12
NovaLT5-1
- 20,000 40,000 60,000 80,000 100,000 120,000 140,000
2 Copyright 2021 Baker Hughes Company. All rights reserved.
PGT25+G5/LM2500+G5
Highest efficiency and power in the 20–40 MW class,
with high-speed and low-speed power turbine options
G5 is the latest technology generation of our PGT25/LM2500
aeroderivative gas turbine family that includes over 2,500 engines
with over 100 million combined operating hours in applications
around the world.
It’s available in two optimized options:
• Max power: 38.3 MW and 41% efficiency
• Xtend: low-emissions (best-in-class NOx emissions <15 ppm)
with extended maintenance (up to 36,000-hour inspection
interval and 72,000-hour overhaul)
Key design features
• High-pressure compressor inherited from G4 with
redesign for enhanced durability
• Combustor leverages latest DLE technologies and
capabilities from the LM6000
• Gas generator leverages GE Aviation technologies;
high-speed power turbine includes aerodynamic and
thermal modifications
3 Copyright 2021 Baker Hughes Company. All rights reserved.
Package
Simplified and flexible solution
• Designed for wide-ranging ambient
conditions
• Fully integrated solutions: single-lift Standard • Footprint: 16 x 3.4 m Standard • Footprint: 18.9 x 4.2 m
GTG/MLO system on CC skid
offshore • Weight: 135 tons pipeline • Weight: 225 tons (PCL600),
• Maximized on-board GT auxiliaries 249 tons (PCL800)
power • High power density: GTC
• Compact BoP solution up to 3 or 4 units in • Alternative packages
generation a single module solutions available
• Pre-assembled unit (PAU) available
as an option
Optimized transportation and Applications Key design features
shipping • Onshore and • Plug and play: only 4 skids to ship for offshore GTG, 6 skids to
• Boxes and packing optimization, main offshore ship for pipeline GTC
items modularized, reduced loose items • LNG, pipeline, gas • Fast Installation and commissioning: package can be shipped
• Easier transportation: total weight and processing including engine, flushed and with loop-check complete
footprint reduced • Power generation: • Quick to first oil: target 12 months delivery time
• Designed for installation: maximized 50/60 Hz with no • Extended maintenance intervals: 10-30-60k hours
on-skid auxiliaries for plug-and-play need of a gearbox
experience • Fast engine swap: 48 hours, digital connected for AM&D
4 Copyright 2021 Baker Hughes Company. All rights reserved.
Datasheet LM2500+G5
PGT25+G5
Two optimized options Xtend 15 ppm Max power Other capabilities
available:
highlights
Power generation—LM2500+G5 50 Hz Power generation—LM2500+G5 50 Hz
Max power: 38.3 MW and • Single annular
Power MWe 32.9 Power MWe 36.8
41% efficiency combustor technology
Efficency % 39.4 Efficency % 40
• MWI fuel flexibility:
Xtend: low-emissions Nox ppm 15 Nox ppm 25
25-63 BTU/scf r^0.5
(best-in-class NOx Exhaust °C 535 Exhaust °C 560
emissions as low as 15 to • Up to 5% vol H2
Speed rpm 1,500 to 3,150 Speed rpm 1,500 to 3,150
25 ppm) with extended
maintenance (up to
36,000-hour inspection Mechanical drive—PGT25+G5 Mechanical drive—PGT25+G5
interval and 72,000-hour Power MW 34 Power MW 38.3
overhaul)
Efficency % 40 Efficency % 41
Nox ppm 15 Nox ppm 25 Package—power generation
Exhaust °C 512 Exhaust °C 540 Footprint m 16 x 3.4 (LxW)
Speed rpm 3,050 to 6,450 Speed rpm 3,050 to 6,450
Package—mechanical drive
Main inspections Main inspections Footprint m 18.9 x 4.2 (LxW)
Hot gas path hours 36,000 Hot gas path hours 25,000
Major insp. hours 72,000 Major insp. hours 50,000
ISO conditions with natural gas fuel, ambient temperature 15ºC,
5 Copyright 2021 Baker Hughes Company. All rights reserved. no inlet or exhaust losses, sea level, 60% relative humidity.
Maintenance intervals adjustable on conditions.
Product line overview
Other LM2500/PGT25 family solutions
+G4 Plus Base Two-shaft turbines with well-known
technology for high efficiency, reliability,
Power generation LM2500+G4 50 Hz LM2500+ 50 Hz LM2500 base 50 Hz availability, and low environmental
impact
Power MWe 32.5 30.5 22.6
Efficency % 37 37.3 35
Other capabilities highlights
Nox ppm 25 15 15
• Single annular combustor technology
Exhaust °C 543 528 540
• Available with both SAC and DLE
Speed rpm 1,500 to 3,150 1,500 to 3,150 1,500 to 3,150
combustors
Mechanical drive PGT25+G4 PGT25+ PGT25 base • Maximized fuel flexibility: can operate
on a wide range of liquid and gas fuels
Power MWe 33.7 31.1 23.3
Efficency % 40.5 40.5 36.1
• Up to 75% vol H2 in SAC configuration
Nox ppm 25 15 15 • Up to 5% vol H2 in DLE configuration
Exhaust °C 510 500 530 • Modular exchange philosophy and
easy maintenance deliver best-in-
Speed rpm 3,050 to 6,405 3,050 to 6,405 3,050 to 6,405
class availability and reliability
Main inspections
Hot gas path hours 25,000 25,000 25,000
Major insp. hours 50,000 50,000 50,000
ISO conditions with natural gas fuel, ambient temperature 15ºC,
6 Copyright 2021 Baker Hughes Company. All rights reserved. no inlet or exhaust losses, sea level, 60% relative humidity.
Maintenance intervals adjustable on conditions.