0% found this document useful (0 votes)
19 views2 pages

19 - Dse 9461

The DSE9460/9461 series are enclosed intelligent battery chargers available in 5 AMP and 10 AMP options for 12V and 24V systems, designed for safety and optimized battery performance. They feature advanced charging profiles, configurable settings, and can be integrated into external systems via MODBUS RTU. The chargers include various protections and can operate in a wide temperature range, making them suitable for diverse applications.

Uploaded by

Rocket12 Bungie
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
19 views2 pages

19 - Dse 9461

The DSE9460/9461 series are enclosed intelligent battery chargers available in 5 AMP and 10 AMP options for 12V and 24V systems, designed for safety and optimized battery performance. They feature advanced charging profiles, configurable settings, and can be integrated into external systems via MODBUS RTU. The chargers include various protections and can operate in a wide temperature range, making them suitable for diverse applications.

Uploaded by

Rocket12 Bungie
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

®

DSEPower

DSE9460/9461 ENVIRONMENTAL TESTING STANDARDS

ELECTRO-MAGNETIC COMPATIBILITY

ENCLOSED INTELLIGENT BATTERY CHARGER BS EN 61000-6-2


EMC Generic Immunity Standard for
5 AMP & 10 AMP, 12 VOLT & 24 VOLT OPTIONS the Industrial Environment
BS EN 61000-6-4
EMC Generic Emission Standard for
the Industrial Environment
FEATURES TEMPERATURE
BS EN 60068-2-1
Ab/Ae Cold Test -30 oC
BS EN 60068-2-2
The DSE94xx series of metal A comprehensive range of input and AVAILABLE 5 AMP VERSIONS
Bb/Be Dry Heat +80 oC
* Refer to de-rating curve in the DSE9000
enclosed intelligent battery chargers output protections ensures a
12v 5A (LCD)
Operator Manual

12v 5A (LCD & Meters)


have been developed with safety, continued safe charging 9460-01

24v 5A (LCD)
9460-02 VIBRATION
usability, optimised battery environment also enabling the use of
24v 5A (LCD & Meters)
9460-11 BS EN 60068-2-6
performance and maximum battery the charger as a power supply. 9460-12 Ten sweeps in each of three
lifetimes in mind. Higher charging / power supply major axes
5 Hz to 8 Hz at +/-7.5 mm,
currents can be achieved by linking 8 Hz to 500 Hz at 2 gn
The DSE94xx series can be used together multiple chargers from this
directly from the box, relying on a series. HUMIDITY
BS EN 60068-2-30
preconfigured lead/acid charging Db Damp Heat Cyclic 20/55 oC
AVAILABLE 10 AMP VERSIONS
curve and selected manually for The chargers can be integrated into at 95% RH 48 Hours
12v 10A (LCD)
either 12V or 24V operation an external system through modbus BS EN 60068-2-78
12v 10A (LCD & Meters)
9461-01
Cab Damp Heat Static 40 oC
24v 10A (LCD)
(including a voltage trimming RTU using RS485 as well as an 9461-02
at 93% RH 48 Hours
24v 10A (LCD & Meters)
9461-11
potentiometer function). Alternatively optional external remote LCD 9461-12 SHOCK
they can be connected via a USB to display being available. BS EN 60068-2-27
a PC (using the free DSE PC Three shocks in each of three major axes
configuration suite software) and can 15 gn in 11 mS
be configured with pre set charging
curves for different battery types.
The user also has the option of
configuring their own bespoke
charging curve for advanced battery
applications.

COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF


BATTERY CHARGER APPLICATIONS
PC MODBUS/DSE2541 DISPLAY DSE2541

1ph
12V
N

CHARGE OUTPUT USB PORT RS485 AUXILIARY DC OUTPUT AC POWER SUPPLY

DSE9460/DSE9461
7

OTHER

TEMPERATURE SENSOR CHANGE OVER VOLTS FREE FAULT CONFIGURABLE INPUT


RELAY

PT1000 ONLY

1 1

NFPA 20 NFPA 110


(QWIR) ISSUE 1
®

DSEPower

DSE9460/9461 SPECIFICATION

AC SUPPLY

ENCLOSED INTELLIGENT BATTERY CHARGER VOLTAGE RANGE


90 V to 305 V (L-N)
5 AMP & 10 AMP, 12 VOLT & 24 VOLT OPTIONS FREQUENCY RANGE
48 Hz to 64 Hz (L-N)

DC OUTPUT RATING
DSE9460 OUTPUT
FEATURES 5 A DC at 12 V & 24 V DC

DSE9461 OUTPUT
10 A DC at 12 V & 24 V DC

RIPPLE AND NOISE


<1%

EFFICIENCY
ADVANCED FEATURES >86%
• Intelligent two, three and four stage charging
profiles AUXILIARY OUTPUT
100 mA DC at 12 V
• Configurable to suit most battery types
(12V/24V) REGULATION
• Adjustable current limit LINE
<0.5%
• Can be used as a battery charger, power supply
or both at the same time LOAD
• Automatic or Manual boost and storage charge 2%

functions to help maintain battery condition TEMPERATURE SENSOR INPUT


• Digital Microprocessor Technology PT1000
• Temperature compensation for battery charging PROTECTIONS
• Low Output Ripple and superb line regulation Short Circuit
• Available in two variants (LCD display or LCD DC Over Voltage
DC Over Current
display & analogue meters) Reverse Polarity
Full Protection Over Temperature
AC Under & Over Voltage
• AC input Under voltage Battery Charger Failure
• AC input Over voltage
• Battery charger output Over voltage CHARGE FAILURE RELAY
3 A at 30 V DC volt free relay
• Battery charger output Over current
• Battery temperature compensation with over DIMENSIONS
temperature protection OVERALL
165 mm x 305 mm x 110 mm
• Output short circuit and Inversion polarity with 6.5” x 12” x 4.3”
auto recovery
• Automatic power de-rating at high ambient WEIGHT
2.3 kg
temperatures
KEY BENEFITS
• Battery charger failure indication OPERATING TEMPERATURE RANGE
• Fully flexible to maximise the life of the battery
-22 °F to +122 °F
-30 oC to +55 oC
Automatic Boost Mode • Suitable for a wide range of battery types
• Boosts and equalises cell charge improving • Switched mode design
battery performance and life STORAGE TEMPERATURE RANGE
• Fault output
-40 °F to +185 °F
-40 oC to +85 oC
Power Save Mode • Minimum 86% efficiency throughout full
• Once the battery is fully charged the chargers operating range
switch to Eco-Power to save energy • No external intervention for boost mode
Communication • Multiple chargers can be linked together to
• Can be integrated into external systems through provide larger current output
MODBUS RTU using RS485 • Can be permanently connected to battery and
• Fully configurable via DSE Configuration Suite mains (utility) supply. No need to disconnect
PC Software through high load conditions.
• External remote LCD option

RELATED MATERIALS
TITLE PART NO’S
DSE9000 Configuration Suite PC Software Manual 057-159
DSE Configuration Suite Installation & Operator Manual 057-151
DSE9460/DSE9461 Series Installation Instructions 053-148
DSE9460/DSE9461 Series Operator Manual 057-176
DSE2541 Data Sheet 055-160
DSE2541 Installation Instructions 053-154

DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA


Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL [email protected] WEBSITE www.deepseaplc.com EMAIL [email protected] WEBSITE www.deepseausa.com

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649 055-153/11/12 (4)
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457