0% found this document useful (0 votes)
51 views4 pages

High Current Test Sets

Phenix Technologies offers high current/circuit breaker test sets with output ranging from 8,000 to 75,000 amps, designed for testing low voltage circuit breakers, current transformers, and motor overload relays. The models available include HC-8C, HC-12C, HC-20C, HC-40C, and HC-75C, featuring fully automated testing, programmable phase angle firing, and various testing modes. Safety features and user-friendly software enhance the testing process, ensuring precise and repeatable results.

Uploaded by

kimalelone
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
51 views4 pages

High Current Test Sets

Phenix Technologies offers high current/circuit breaker test sets with output ranging from 8,000 to 75,000 amps, designed for testing low voltage circuit breakers, current transformers, and motor overload relays. The models available include HC-8C, HC-12C, HC-20C, HC-40C, and HC-75C, featuring fully automated testing, programmable phase angle firing, and various testing modes. Safety features and user-friendly software enhance the testing process, ensuring precise and repeatable results.

Uploaded by

kimalelone
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

R

High Current/Circuit Breaker Test Sets


8,000 – 75,000 Amp Output PHENIX
TECHNOLOGIES

Testing Applications Models Available


• Test virtually any low voltage, molded case, or metal • HC-8C • HC- 40C
clad direct acting AC circuit breaker by simulating • HC-12C • HC-75C
overload and fault conditions • HC-20C
• Test current transformers and thermal or magnetic
motor overload relays
➤ Fully automated testing
• Configured in a series, can be used for substation
maintenance, primary injection testing on high ➤ Precise, repeatable current pulses with
voltage circuit breakers and protective relays minimal distortion
➤ Current wave form display
➤ ISO17025 calibration upon request

Model HC-8C

Model Model
HC-20C HC-75C
CIRCUIT BREAKER PORTABLE

VACUUM
INTERRUPTER

Specifications are subject to change without notice. Brochure No. 30208


Safety and Design Features Computer-Control via WIN HC Software
• Circuit breaker protection User-friendly, menu-driven commands provide advanced
• Control power switch with indicator and Output database and report capabilities for test duplication
On indicator and recall, report generation, and current wave shape
display.
• Interlock open indicator
• Emergency Off pushbutton
• Highly reliable SCR’s combined with programmable Testing Modes
phase angle firing system
• Continuously variable output over entire test range • Normal – the operator manually controls all functions
utilizing a motorized vernier and programmable tap of the test set.
selector allowing for both auto-jog and current-hold • Jog-to-Hold – the test set jogs the output on at “Jog
capabilities on Cycles” and off for “Jog off Secs” and raises the
• Sensing circuit selectable between current or contacts output until the “Hold Amps” is reached.
• Digital AC voltmeter for monitoring input, output, • Jog-to-Trip – the test set jogs the output on at “Jog
and external voltage up to 600 VAC on Cycles” and off for “Jog off Secs” until the circuit
breaker under test trips.
• Currentmeter accuracy 0.8% of reading +0.3%
• Current Hold – the output is held to within 1% of
of range
the “Hold Amps”.
• Meters calibrated with standards certified by NIST
• Memory – used for testing the sensitivity pickup of
• Standard HCSS1 and HCSS2 stab sets supplied with electronic controllers (when the stop button is
optional stab sets available (for models HC12C, pressed, the current level is recalled).
HC20C, HC40C and HC75C only)
• Operation/maintenance manual
Programmable Phase Angle Firing
This feature assures precisely repeatable current pulses
with minimal distortion and DC offset. This is achieved
by combining the use of highly reliable SCR’s and
computer-controlled firing system.

Wave Form Display


This feature allows for viewing of the current wave form
injected through the breaker. Detection of DC offset
or contact bounce can be seen. With the use of the
programmable phase angle firing circuit, DC offset may
be corrected by varying the firing phase angle.

www.phenixtech.com
MODEL HC8C HC12C HC20C HC40C HC75C
220-240 V, 100 A, 50/60 Hz 240 V, 60 A, 60 Hz 240 V, 150 A, 60 Hz 240 V, 320 A, 60 Hz 480 V, 400 A, 60 Hz
INPUT
480 V, 50 A, 60 Hz 480 V, 30 A, 60 Hz 480 V, 75 A, 60 Hz 480 V, 160 A, 60 Hz 400 V, 400 A, 50 Hz
(50 Hz or 60 Hz
400 V, 50 A, 60 Hz 400 V, 30 A, 50 Hz 400 V, 75 A, 50 Hz 400 V, 160 A, 50 Hz  
must be specified)
Input currents based on 30 minute output ratings. Other input voltages are available, for example; 380 V, 50 Hz or 600 V, 60 Hz

NUMBER of TAPS 3 3 4 6 8

OPEN CIRCUIT VOLTAGES



OUTPUT VOLTAGE 8 / 16 / 32 V @ 240/480 V, 60 Hz Parallel Series Parallel Series Parallel Series Parallel Series
7.7 / 15.3 / 30.7 V @ 230 V, 50 Hz 6.25 V, 50 Hz 12.5 V, 50 Hz 8.3 V, 50 Hz 16.6 V, 50 Hz 10 V, 50 Hz 20 V, 50 Hz 13.3 V, 50 Hz 26.6 V, 50 Hz
6.7 / 13.3 / 26.7 V @ 400 V,50 Hz 7.5 V, 60 Hz 15 V, 60 Hz 10 V, 60 Hz 20 V, 60 Hz 12 V, 60 Hz 24 V, 60 Hz 16 V, 60 Hz 32 V, 60 Hz

OUTPUT CURRENT   Parallel Series Parallel Series Parallel Series Parallel Series
Continuous Duty 2000 / 1000 / 500 A 1200 A 600 A 2000 A 1000 A 4000 A 2000 A 7500 A 3750 A
30 min ON / 30 min OFF 2800 / 1400 / 700 A 1700 A 850 A 3000 A 1500 A 6000 A 3000 A 10,000 A 5000 A
1 min ON / 10 min OFF 4000 / 2000 / 1000 A 2500 A 1250 A 4500 A 2250 A 9000 A 4500 A 15,000 A 7500 A
1 sec ON / 2 min OFF 8000 / 4000 / 2000 A 12,000 A 6000 A 20,000 A 10,000 A 40,000 A 20,000 A 75,000 A 37,500 A

DIMENSIONS / WEIGHT
(approx)              
Regulator          
Length 21” (533 mm)  27 3/8” (695 mm) 29 3/8” (746 mm)       
Width 28 1/8” (714 mm) 25 3/4” (654 mm) 25 3/4” (654 mm) Regulator & Transformer
Height 48 1/2” (1232 mm) 17 7/8” (454 mm) 19 3/8” (492 mm) are enclosed in 1 cabinet
Weight 325 lbs. (147 kgs) 165 lbs (75 kgs) 200 lbs (91 kgs)
Transformer            
Length 20” (508 mm) 28 1/4” (718 mm)  30 1/4” (768 mm)       
Regulator & Transformer
Width 28 1/8” (714 mm) 26 5/8” (676 mm)  26 5/8” (676 mm)       
are enclosed in 1 cabinet
  Height 48 1/2” (1232 mm) 27” (686 mm) 27” (686 mm)       
  Weight 375 lbs. (170 kgs) 300 lbs. (196 kgs)   350 lbs. (159 kgs)      
     
Total Unit
           
(Regulator Length 28 1/4” (718 mm) 30 1/4” (768 mm)  45” (1143 mm)  45” (1143 mm) 
and Trans- Regulator & Transformer
   
former) Width 26 5/8” (676 mm) 26 5/8” (676 mm)  27” (686 mm)  27” (686 mm) 
are 2 stand-alone cabinets
     Height 44 1/4” (1124 mm) 45 1/4” (1149 mm) 46” (1168 mm)  46” (1168 mm) 
     Weight 465 lbs. (211 kgs) 550 lbs. (249 kgs)   1125 lbs. (512 kgs) 1300 lbs. (590 kgs) 
     
SHIPPING SIZE            
Length 51” (1295 mm) 41” (1041 mm)  41” (1041 mm)  59” (1499 mm)  59” (1499 mm) 
   Width 36” (914 mm)  33” (838 mm)  33” (838 mm) 36” (914 mm)  36” (914 mm) 
  Height 57” (1448 mm) 68” (1727 mm) 68” (1727 mm)   70” (1778 mm) 70” (1778 mm) 
  Weight 1030 lbs. (467 kgs)  780 lbs (354 kgs)  840 lbs (381 kgs)  1400 lbs (635 kgs) 1620 lbs (735 kgs) 
     
CABLES INCLUDED    
Output Leads

4/0 (107 m m2) 5’ (1.5 m) (8) 5’ (1.5 m) (8) 5’ (1.5 m) (8) n/a n/a

Continuity Sense/

Auxiliary Contact Leads 5’ (1.5 m) (2) 5’ (1.5 m) (2) 5’ (1.5 m) (2) 5’ (1.5 m) (2) 5’ (1.5 m) (2)

+1.301.746.8118
Output Stabs for connection to the circuit breaker under test
(for models HC12C, HC20C, HC40C, HC75C only)

HCSS1 HCSS2 HCSS3 HCSS4

HCSS5 HCSS6 HCSS8

HCSS7

Model # Connection to Circuit Breaker

Options
INCLUDED

HCSS1 .5” (12.7 mm) thick blade

HCSS2 .75” (19.05 mm) thick blade • Multiple-tap input Auto Transformer for 208, 240,
480, 575 operation – 480 V or 575 V units
HCSS3 3.15” (80 mm) clamp diameter • Stab Plate Adapter for Series Output Connection
HCSS4 3.5” (88.9 mm) diameter • External Printer
OPTIONAL

HCSS5 3.15” (80 mm) clamp diameter • Heavy-duty, coated-canvas, Protective Dust Cover
HCSS6 2.25” (57.15 mm) diameter (included with models HC12C and HC20C)

HCSS7
.5” (12.7 mm) thick blade • DC circuit breaker testing systems available
10.5” (266.7 mm) long
• ISO17025 calibration
HCSS8 2” (50.8 mm) diameter

PHENIX
TECHNOLOGIES
World Headquarters Branch Offices
Phenix Technologies, Inc. Phenix Systems AG
75 Speicher Drive Riehenstrasse 62A, 4058 Basel, Switzerland
Accident, MD 21520 USA Ph: +41.61.383.2770, [email protected]
Ph: +1.301.746.8118 Phenix Asia
Fx: +1.301.895.5570 Zhong Cheng Rd, Sec 1, No 177, 2F, Taipei 11148 Taiwan
[email protected] Ph: +886.2.2835.9738, Fx: +886.2.2835.9879, [email protected]

www.phenixtech.com © Copyright – Phenix Technologies, Inc. 2/2021