Inbound 1466109201020850920
Inbound 1466109201020850920
0.10
4" Ø PVC PIPE
1. ALL PLUMBING WORKS SHALL CONFORM WITH UNLESS OTHERWISE INDICATED.
15MM Ø CWL THE PROVISIONS OF RA1378, (NATIONAL PLUMBING
CODE OF THE PHILPPINES, 1999) AND THE RULES AND
370
PIPE CLAMP 50mmØ BEND VENT
`AIR CHAMBER: ALL INDIVIDUAL
REGULATIONS OF THE LOCAL HEALTH ORDINANCES.
0.40
0.60
COUNTER SUNK
BRANCHES TO FIXTURE OR GROUP OF
FLOOR CLEAN OUT WATER PROOFING I L O I L O C I T Y
MEMBRANE FIXTURES AND/OR EQUIPMENT
1OOmmØ X 5oØ-14
BEND W/ 5OmmØ
2. ALL PLUMBING PIPES & FITTINGS, WASTE SHALL BE PROVIDED WITH AIR
SIDE OPENING
PIPES MOLDEX SANIMOLD EXTRA;
0.10
CHAMBER CAPPED VERTICAL PIPE
HANGER ROD WATER SUPPLY PIPES; MOLDEX BLUE PIPES; GATE EXTENSION OF DIMENSION AS IN
VALVES & CHECK VALVES CRANE; FIXTURES & DETAIL.
0.60
100MM Ø SOIL PIPE
TO
FLOOR FLANGE
ACCESSORIES - AMERICAN STANDARD;
0.10 0.40 0.10
100mm Ø SOIL PIPE
50mm THK. CONC.
100MM Ø SOIL PIPE STACK
S E C T I O N
LEADER/DOWNSPOUT - PVC S1000 PIPES; FREE FROM `ALL SEWER LINES SHALL BE
SECTION/ELEVATION SLAB W/ 10mm Ø GRAB BAR ALL DEFECTS & DEFORMITIES. SANIMOLD EXTRA UPVC PIPE (HD)
0.05
COUNTER SUNK
FLOOR CLEAN OUT 100mm Ø SOIL PIPE 3. ALL HORIZONTAL WASTE/ DRAIN PIPES `ALL MAIN VENT STACKS SHALL BE
4"x 8"x 16" CHB WALL W/ 5OmmØ VENT
HAVING A DIAMETERS OF 100mm OR LESS SHALL UPVC PIPE SERIES 1,000
10mmØ REBARS SPACED P L U M B I N G
53O
HAVE A MINIMUM GRADE OF 2%; PIPES OF DIAMETER
0.45
@ 400mm O.C. BOTHWAYS
0.60
PLAN 15MMØ CWL LARGER THAN 110mm, A MINIMUM GRADE OF 1%. `ALL CIRCUIT VENT SHALL BE UPVC
PIPE SERIES 1,000
100mm THK. CONC. SLAB P L A N
4. ALL PLUMBING PIPES, HORIZONTAL OR STACK, P L U M B I N G
0.10
SLAB SOFFIT
APPROVAL
MH MAN HOLE
????
????
I,____________________________________
???
GV
150
THEN ATTACHED BY ME WHEN APPLYING FOR THE FOR THE CERTIFICATE OF OCCUPANCY. GATE VALVE
P L A N 150 MM THK. CHB THE UNDERSIGNED ALSO ACKNOWLEGDE TO ABIDE WITH THE PROVISION STATED IN TABLE B-1 OF
S E C T I O N THE NATIONAL PLUMBING CODE OF THE PHILIPPINES. CV CHECK VALVE
10 mm Ø RSB @ 300 MM O.C B.W.
OWNER
P-2 SCALE: 1:20 MTS
DONE BY: DESIGN BY: PROJECT TITLE: OWNER: REVISIONS: SHEET NO.:
ALL DESIGNS, DRAWINGS, SPECIFICATIONS &
COPIES PREPARED AND FURNISHED BY THE
PROPOSED 2-STOREY RESIDENTIAL BUILDING
MASTER PLUMBER
ARCHITECT IN CONNECTION WITH THE PROJECT
ARE INSTRUMENTS OF PROFESSIONAL SERVICE,
MARIA KURDAPYA
2
PRC REG. NO: PTR NO:
THEY ARE THE PROPERTY OF THE ARCHITECT,
WHETHER THEY ARE EXECUTED OR NOT, THEY ARE LOCATION: SHEET CONTENTS: P
VALIDITY: DATE ISSUED:
NOT TO BE REPRODUCED OR USE ON OTHER WORK
EXCEPT IF WRITTEN AGREEMENT WITH THE
ARCHITECT. ILOILO CITY
WATER CLOSET MOUNTING DETAIL, NOTES: FOR SOIL, VENT & WASTE SYSTEM, NOTES: FOR COLD
WATERLINE SYSTEM, PLUMBING ANALYSIS, UNDERTAKING, SEPTIC TANK DETAIL, SPECIFICATIONS,
GENERAL NOTES & PLUMBING SYMBOLS, AIR CHAMBER DTL., WATER METER DTL., CATCH BASIN
DRAWN BY: RONOROA ZORO 2
TIN: PLACE: , ILOILO CITY AND CLEAN OUT DETAIL.
RA 9266, ART 4, SEC 33