Design Examples of RC Beams
Design Examples of RC Beams
Load Combination:
Design load w:
𝑤 = 1.35𝑔 + 1.5𝑞 = 1.35𝑥7 + 1.5𝑥5 = 16.95 𝑘𝑁/𝑚
Analysis:
Design moment 𝑀 at mid-span:
𝑤𝑙 16.95𝑥8
𝑀 = = = 135.6 𝑘𝑁𝑚
8 8
Shear Force 𝑉 at support:
𝑤𝑙 16.95𝑥8
𝑉= = = 67.8 𝑘𝑁
2 2
Flexural Design:
Minimum effective depth to avoid any compression steel (singly reinforced) is given by:
𝑀
<𝐾 = 0.295
𝑓 𝑏𝑑
𝑀
𝑑 ≥
0.295𝑥𝑏𝑥𝑓
135.6𝑥10
=
0.295𝑥250𝑥14.167
= 360.255 𝑚𝑚
Page 1
Reinforced Concrete Structures I
Assuming 30 mm cover, 20 mm diameter bars and 8 mm link diameter, the overall depth D of the
beam is:
20
𝐷 = 360.255 + 30 + 8 + = 408.255 𝑚𝑚
2
Use 𝐷 = 450 𝑚𝑚
20
→ 𝑑 = 450 − 30 − 8 − = 402 𝑚𝑚
2
Check the depth to avoid any compression steel:
Ultimate moment of resistance 𝑀 :
2
𝑀 = 0.295𝑓𝑐𝑑𝑏𝑑 = 0.295𝑥14.167𝑥250𝑥4022 = 168.846 𝑘𝑁𝑚
Since 𝑀 < 𝑀 design as a singly reinforced beam.
𝑀 135.6𝑥106
𝐾= = = 0.237
250𝑥4022 𝑥14.167
𝑏𝑑 𝑓
𝑑 402
𝑧 = 1 + √1 − 2𝐾 = [1 + 1 − 2𝑥0.237] ≤ 0.95𝑑
2 2
= 346.801 𝑚𝑚
𝑀 135.6𝑥10
𝐴 = =
𝑓 𝑧 434.78𝑥346.801
𝐴 = 899.311 𝑚𝑚
899.311
𝑁𝑢𝑚𝑏𝑒𝑟 𝑜𝑓 𝜙20𝑚𝑚 𝑏𝑎𝑟 = = 2.86
314.159
⇨ 𝑼𝒔𝒆 𝟑𝝓𝟐𝟎 𝒎𝒎 𝒃𝒂𝒓𝒔 (𝑨𝒔 = 𝟗𝟒𝟐. 𝟒𝟖 𝒎𝒎𝟐 )
Shear Design:
Design Shear Force, 𝑉 :
This should be determined at distance d from the face of the support but for simplicity has been
calculated at the centre of supports.
𝑉 = 67.8 − 16.95𝑑 = 67.8 − 16.95𝑥0.402 = 60.99 𝑘𝑁
Shear Resistance of Concrete (𝑉 , ):
. .
𝐶 , = = = 0.12 𝑁/𝑚𝑚
.
Page 2
Reinforced Concrete Structures I
Assuming all the tension reinforcement is taken onto supports and anchored:
.
ρ = = = 0.0094 < 0.02 𝑂𝑘
𝜎 =0
/ / / /
𝑣 = 0.035𝑘 𝑓 = 0.035(1.71) (25) = 0.391 𝑁/𝑚𝑚
𝑉 , = [𝐶 , 𝑘(100𝜌 𝑓 ) + 𝑘 𝜎 ]𝑏 𝑑
𝜌 , = (0.08 𝑓 )/𝑓
= (0.08√25)/500 = 0.0008
𝜌 , = 𝐴 /(𝑠𝑏 sin 𝛼)
Page 3
Reinforced Concrete Structures I
⇒ =( )( )( . )
= 0.155
. .
1𝑥20 = 20𝑚𝑚
The provided clear distance = 57𝑚𝑚 > 𝑚𝑎𝑥 𝑑 + 5 𝑚𝑚
20 𝑚𝑚
Therefore, it is ok!
Page 4
Reinforced Concrete Structures I
Solution
Material Properties:
. .
For C25/30 concrete: 𝑓 = 25 𝑀𝑃𝑎 →𝑓 = = = 14.167 𝑀𝑃𝑎
.
/ /
→𝑓 = 0.3𝑓 = 0.3(25) = 2.6 𝑀𝑃𝑎
Load Combination:
Design load w:
𝑤 = 1.35𝑔 + 1.5𝑞 = 1.35𝑥7 + 1.5𝑥5 = 16.95 𝑘𝑁/𝑚
Analysis
Design moment Md at mid-span:
𝑤𝑙 16.95𝑥8
𝑀 = = = 135.6 𝑘𝑁𝑚
8 8
Shear Force 𝑉 at support:
𝑤𝑙 16.95𝑥8
𝑉= = = 67.8 𝑘𝑁
2 2
Page 5
Reinforced Concrete Structures I
Flexural Design:
Effective depth:
Assume diameter of main bar (𝜙) = 24 𝑚𝑚 in one layer with concrete cover 30 mm and 8 mm
link diameter.
Effective depth (𝑑 ) = 𝐶 + 𝜙 + = 30 + 8 + = 46 𝑚𝑚
= = ( )
= 0.319 < 0.38 → Compression steel yields
. .
. ( . . )
𝐴 = = = = 312.013 𝑚𝑚
( ) ( ) . ( )
= 1174.781 𝑚𝑚
⇒ 𝑷𝒓𝒐𝒗𝒊𝒅𝒆 𝟑𝝓𝟐𝟒 (𝑨𝒔 = 𝟏𝟑𝟓𝟕. 𝟏𝟔𝟖 𝒎𝒎𝟐 )
Shear Design:
Design Shear Force, 𝑉 :
This should be determined at distance d from the face of the support but for simplicity has been
calculated at the centre of supports.
𝑉 = 67.8 − 16.95𝑑 = 67.8 − 16.95𝑥0.320 = 62.376 𝑘𝑁
Shear Resistance of Concrete (𝑉 , ):
. .
𝐶 , = = = 0.12 𝑁/𝑚𝑚
.
Page 6
Reinforced Concrete Structures I
Assuming all the tension reinforcement is taken onto supports and anchored:
.
ρ = = = 0.018 < 0.02 𝑂𝑘
𝜎 =0
/ / / /
𝑣 = 0.035𝑘 𝑓 = 0.035(1.79) (25) = 0.419 𝑁/𝑚𝑚
𝑉 , = [𝐶 , 𝑘(100𝜌 𝑓 ) + 𝑘 𝜎 ]𝑏 𝑑
𝜌 , = (0.08 𝑓 )/𝑓
= (0.08√25)/500 = 0.0008
𝜌 , = 𝐴 /(𝑠𝑏 sin 𝛼)
Page 7
Reinforced Concrete Structures I
⇒ =( )( )( . )
= 0.199
. .
1𝑥24 = 24 𝑚𝑚
The provided clear distance = 41𝑚𝑚 > 𝑚𝑎𝑥 𝑑 + 5 𝑚𝑚
20 𝑚𝑚
Therefore, it is ok!
Page 8
Reinforced Concrete Structures I
Load Combination:
Design load w:
𝑤 = 1.35𝑔 + 1.5𝑞 = 1.35𝑥20 + 1.5𝑥11 = 43.5 𝑘𝑁/𝑚
Analysis
Design moment Md at mid-span:
𝑤𝑙 43.5𝑥9
𝑀 = = = 440.4 𝑘𝑁𝑚
8 8
Shear Force 𝑉 at support:
𝑤𝑙 43.5𝑥9
𝑉= = = 195.75 𝑘𝑁
2 2
Flexural Design:
Effective depth:
Assume diameter of main bar (𝜙) = 26 𝑚𝑚 in two layers with concrete cover to the reinforcement
35 mm and 10 mm link diameter.
Effective depth (𝑑) = 𝐷 − 𝐶 − 𝜙 −𝜙 = 575 − 35 − 10 − 26 = 504 𝑚𝑚
2
𝑀 = 0.295𝑓𝑐𝑑𝑏𝑑
= 0.295𝑥14.167𝑥300𝑥504 = 318.480 𝑘𝑁𝑚
Since 𝑀 < 𝑀 design as a doubly reinforced beam. Thus, compression reinforcement is
required.
Page 9
Reinforced Concrete Structures I
Compression Reinforcement (𝐴 ):
𝑑 = 55 𝑚𝑚 (𝑔𝑖𝑣𝑒𝑛)
Then, diameter of compression bars (𝜙 ) = 20 𝑚𝑚.
= = ( )
= 0.243 < 0.38 → Compression steel yields
. .
. ( . . )
𝐴 = = = = 624.538 𝑚𝑚
( ) ( ) . ( )
= 2396.964 𝑚𝑚
⇒ 𝑷𝒓𝒐𝒗𝒊𝒅𝒆 𝟓𝝓𝟐𝟔 (𝑨𝒔 = 𝟐𝟔𝟓𝟒. 𝟔𝟒𝟔 𝒎𝒎𝟐 )
NB: The value of d is slightly changed.
𝑑 for the top 2𝜙26: = 575 − 35 − 10 − 26 − = 491
= = ( )
= 0.241 < 0.38 → Compression steel yields
. .
. ( . . )
𝐴 = = = = 601.041 𝑚𝑚
( ) ( ) . ( )
Page 10
Reinforced Concrete Structures I
= 2384.019 𝑚𝑚
⇒ 𝑷𝒓𝒐𝒗𝒊𝒅𝒆 𝟓𝝓𝟐𝟔 (𝑨𝒔 = 𝟐𝟔𝟓𝟒. 𝟔𝟒𝟔 𝒎𝒎𝟐 )
The top layer 𝟐𝝓𝟐𝟔 can be curtailed.
Stress block depth 𝒂:
𝐴 = 2𝜙26 = 1061.86 𝑚𝑚 , 𝑑 = 𝑑 = 491 𝑚𝑚
1061.86𝑥434.78
𝑓 𝑏𝑎 = 𝐴 𝑓 ⇒𝑎= = 108.63 𝑚𝑚
14.167𝑥300
𝑎
𝑧 = 𝑑 − = 436.69 𝑚𝑚
2
𝑀 = 𝐴 𝑓 𝑧 = 1061.86(434.78)(436.69) = 201.61 𝑘𝑁𝑚
Equating with bending moment equation:
201.61 = 195.75𝑥 − 21.75𝑥
𝑠𝑜𝑙𝑣𝑖𝑛𝑔 𝑥 = 1.19 𝑚 𝑎𝑛𝑑 7.81 𝑚
Shear Design:
Design Shear Force, 𝑉 :
This should be determined at distance d from the face of the support but for simplicity has been
calculated at the centre of supports.
𝑉 = 195.75 − 43.5𝑑 = 195.75 − 43.5𝑥0.507 = 173.70 𝑘𝑁
Shear Resistance of Concrete (𝑉 , ):
. .
𝐶 , = = = 0.12 𝑁/𝑚𝑚
.
Assuming all the tension reinforcement is taken onto supports and anchored:
.
ρ = = = 0.017 < 0.02 𝑂𝑘
𝜎 =0
/ / / /
𝑣 = 0.035𝑘 𝑓 = 0.035(1.63) (25) = 0.364 𝑁/𝑚𝑚
𝑉 , = [𝐶 , 𝑘(100𝜌 𝑓 ) + 𝑘 𝜎 ]𝑏 𝑑
Page 11
Reinforced Concrete Structures I
𝜌 , = (0.08 𝑓 )/𝑓
= (0.08√25)/500 = 0.0008
𝜌 , = 𝐴 /(𝑠𝑏 sin 𝛼)
⇒ ≥ ( . )( )( . )
= 0.35
.
157.08
𝑠≤ = 448.8 𝑚𝑚
0.35
Hence provide 𝜙10 at 350 mm c/c (𝑨𝒔𝒘 /𝒔 = 𝟎. 𝟒𝟓).
The shear resistance of the links actually specified is:
𝑉 = 𝑧𝑓 cot 𝜃
Page 12
Reinforced Concrete Structures I
Spacing of Bars:
1𝑥26 = 26 𝑚𝑚
The provided clear distance = 66𝑚𝑚 > 𝑚𝑎𝑥 𝑑 + 5 𝑚𝑚
20 𝑚𝑚
Therefore, it is ok!
Page 13
Reinforced Concrete Structures I
From Table of maximum bar spacing for crack control, for 0.3 mm crack width, maximum spacing
is approximately 112.5 mm. The actual spacing provided is 66 mm does not exceed 112.5 mm.
The beam is satisfactory with regard to cracking.
Page 14
Reinforced Concrete Structures I
Solution
Material Properties:
. .
For C30 concrete: 𝑓 = 30 𝑀𝑃𝑎 →𝑓 = = = 17 𝑀𝑃𝑎
.
/ /
→𝑓 = 0.3𝑓 = 0.3(30) = 2.9 𝑀𝑃𝑎
Load Combination:
Design load w:
𝑤 = 1.35𝑔 + 1.5𝑞 = 1.35𝑥60 + 1.5𝑥18 = 108 𝑘𝑁/𝑚
Analysis
Design moment Md at mid-span:
𝑤𝑙 108𝑥6
𝑀 = = = 486 𝑘𝑁𝑚
8 8
Shear Force 𝑉 at support:
𝑤𝑙 108𝑥6
𝑉= = = 324 𝑘𝑁
2 2
Flexural Design:
Effective depth (𝑑) = 540 𝑚𝑚 (𝑔𝑖𝑣𝑒𝑛)
2
𝑀 = 0.295𝑓𝑐𝑑𝑏𝑑
= 0.295𝑥17𝑥300𝑥540 = 438.71 𝑘𝑁𝑚
Page 15
Reinforced Concrete Structures I
= = ( )
= 0.206 < 0.38 → Compression steel yields
. .
. ( . )
𝐴 = = = = 221.975 𝑚𝑚
( ) ( ) . ( )
= 2500 𝑚𝑚
⇒ 𝑷𝒓𝒐𝒗𝒊𝒅𝒆 𝟐𝝓𝟐𝟔 𝒂𝒏𝒅 𝟐𝝓𝟑𝟐 (𝑨𝒔 = 𝟐𝟔𝟕𝟎 𝒎𝒎𝟐 )
Curtailment at support
The tension reinforcement should be anchored over the supports with a bend. Two bars may
be curtailed near to the supports. From support 0.08𝑙 = 0.08𝑥6 = 0.48 𝑚.
Shear Design:
Design Shear Force, 𝑉 :
This should be determined at distance d from the face of the support.
Design shear at face of support: 𝑉 = 324 − 108𝑥0.15 = 307.8 𝑘𝑁
At distance d from the face of the support:
𝑉 = 307.8 − 108𝑑 = 307.8 − 108𝑥0.540 = 249.48 𝑘𝑁
Assuming all the tension reinforcement is taken onto supports and anchored:
Page 16
Reinforced Concrete Structures I
𝜎 =0
/ / / /
𝑣 = 0.035𝑘 𝑓 = 0.035(1.609) (30) = 0.391 𝑁/𝑚𝑚
𝑉 , = [𝐶 , 𝑘(100𝜌 𝑓 ) + 𝑘 𝜎 ]𝑏 𝑑
⇒ ≥ ( . )( )( . )
= 0.472
.
100.531
𝑠≤ = 213 𝑚𝑚
0.472
Hence provide 𝜙8 at 200 mm c/c (𝑨𝒔𝒘 /𝒔 = 𝟎. 𝟓𝟎𝟑).
Minimum shear reinforcement, 𝜌 , :
𝜌 , = (0.08 𝑓 )/𝑓
= (0.08√30)/500 = 0.001
Page 17
Reinforced Concrete Structures I
𝜌 , = 𝐴 /(𝑠𝑏 sin 𝛼)
Page 18
Reinforced Concrete Structures I
Page 19
Reinforced Concrete Structures I
1𝑥32 = 32 𝑚𝑚
The provided clear distance = 33 𝑚𝑚 > 𝑚𝑎𝑥 𝑑 + 5 𝑚𝑚
20 𝑚𝑚
Therefore, it is ok!
From Table of maximum bar spacing for crack control, for 0.3 mm crack width, maximum spacing
is approximately 107.5 mm. The actual spacing provided is 33 mm does not exceed 107.5 mm.
The beam is satisfactory with regard to cracking.
Page 20
Reinforced Concrete Structures I
Design Loads
Since the beams are spaced at 2 m centres, the loads on the beam are:
𝐷𝑒𝑎𝑑 𝑙𝑜𝑎𝑑 = 7.4 × 2 = 14.8 𝑘𝑁/𝑚
𝐿𝑖𝑣𝑒 𝑙𝑜𝑎𝑑 = 5 × 2 = 10 𝑘𝑁/𝑚
Design load = (1.35 × 14.8) + (1.5 × 10) = 35.0 𝑘𝑁/𝑚
Analysis
Ultimate moment at mid-span = 35.0 × 6 /8 = 157.5 𝑘𝑁 𝑚
Shear Force 𝑉 at support:
𝑤𝑙 35𝑥6
𝑉= = = 105 𝑘𝑁
2 2
Effective Width
𝑏 = 𝑏 + 𝑏 + 𝑏 = 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 𝑜𝑓 𝑏𝑒𝑎𝑚 = 2000 𝑚𝑚
2000 − 250
𝑏 =𝑏 = = 875 𝑚𝑚
2
𝑙 = Span of simply supported beam = 6000 mm
𝑏 = 𝑏 , +𝑏 ≤𝑏
Page 21
Reinforced Concrete Structures I
(= 157.5 𝑘𝑁𝑚). Therefore, the beam can be designed as a rectangular beam of size 1800 × 304.
Flexural Design
𝑀 157.5 𝑥 10
𝐾= = = 0.067
𝑏 𝑑 𝑓 1800 𝑥 3042 𝑥 14.167
𝑑 304
𝑧= 1 + √1 − 2𝐾 = 1+ 1 − 2(0.067) = 293.45 𝑚𝑚 ≤ 0.95𝑑
2 2
𝑀 157.5 𝑥 10
𝐴 = = = 1254 𝑚𝑚2
𝑓 𝑧 434.783 𝑥 288.8 𝑚𝑚
⇒ 𝑷𝒓𝒐𝒗𝒊𝒅𝒆 𝟑𝝓𝟐𝟔 (𝑨𝒔 = 𝟏𝟓𝟗𝟐. 𝟖 𝒎𝒎𝟐 )
Design for Shear
At d distance from face of support (from center of support for simplification):
𝑉 = 105 − 35 𝑥 0.304 = 94.36 𝑘𝑁
Shear Resistance of Concrete (𝑉 , ):
. .
𝐶 , = = = 0.12 𝑁/𝑚𝑚
.
Assuming all the tension reinforcement is taken onto supports and anchored:
Page 22
Reinforced Concrete Structures I
.
ρ = = = 0.02 < 0.02 𝑂𝑘
𝜎 =0
/ / / /
𝑣 = 0.035𝑘 𝑓 = 0.035(1.811) (30) = 0.467 𝑁/𝑚𝑚
𝑉 , = [𝐶 , 𝑘(100𝜌 𝑓 ) + 𝑘 𝜎 ]𝑏 𝑑
𝜌 , = (0.08 𝑓 )/𝑓
= (0.08√25)/500 = 0.0008
𝜌 , = 𝐴 /(𝑠𝑏 sin 𝛼)
Page 23
Reinforced Concrete Structures I
1𝑥26 = 26 𝑚𝑚
The provided clear distance = 53 𝑚𝑚 > 𝑚𝑎𝑥 𝑑 + 5 𝑚𝑚 Therefore, it is ok!
20 𝑚𝑚
Check for cracking
Steel stress at SLS = 𝑆𝑡𝑒𝑒𝑙 𝑠𝑡𝑟𝑒𝑠𝑠 𝑎𝑡 𝑈𝐿𝑆 × [𝑞𝑢𝑎𝑠𝑖 − 𝑝𝑒𝑟𝑚𝑎𝑛𝑒𝑛𝑡 𝑙𝑜𝑎𝑑/𝑙𝑜𝑎𝑑 𝑎𝑡 𝑈𝐿𝑆]
= 𝑓 𝑥 𝑞𝑢𝑎𝑠𝑖 − 𝑝𝑒𝑟𝑚𝑎𝑛𝑒𝑛𝑡 𝑙𝑜𝑎𝑑/𝑙𝑜𝑎𝑑 𝑎𝑡 𝑈𝐿𝑆
.
= 434.78 𝑥 = 308 𝑀𝑃𝑎
From Table of maximum bar spacing for crack control, for 0.3 mm crack width, maximum spacing
is approximately 115 mm. The actual spacing provided is 53 mm does not exceed 115 mm. The
beam is satisfactory with regard to cracking.
Page 24
Reinforced Concrete Structures I
0.36𝑑𝑓 𝑏 + 𝑓 𝑡 𝑏 −𝑏
𝐴 = +𝐴
𝑓
Page 25
Reinforced Concrete Structures I
Page 26
Reinforced Concrete Structures I
Solution
Material Properties:
. .
For 𝐶30 concrete: 𝑓 = 30 𝑀𝑃𝑎 →𝑓 = = = 17 𝑀𝑃𝑎
.
/ /
→𝑓 = 0.3𝑓 = 0.3(30) = 2.9 𝑀𝑃𝑎
Design Load
𝑤 = 190 𝑘𝑁/𝑚
Analysis
The analysis values are shown on the figure.
Flexural Design:
Mid-span of 1st and 3rd end spans → design as a T-section
𝑀𝑜𝑚𝑒𝑛𝑡 = 428 𝑘𝑁𝑚 𝑠𝑎𝑔𝑔𝑖𝑛𝑔
Effective width of flange (𝑏 ):
𝑏 =𝑏 , +𝑏 +𝑏 ,
Page 27
Reinforced Concrete Structures I
𝐴 = = = 1672.16 𝑚𝑚
. .
𝑷𝒓𝒐𝒗𝒊𝒅𝒆 𝟑𝝓𝟐𝟒 𝒂𝒏𝒅 𝟐𝝓𝟏𝟔 𝒃𝒂𝒓𝒔. (𝑨𝒔 = 𝟏𝟕𝟓𝟗. 𝟐𝟗 𝒎𝒎𝟐 )𝒃𝒐𝒕𝒕𝒐𝒎 𝒔𝒕𝒆𝒆𝒍
Interior supports → design as rectangular section
𝑀 = 523 𝑘𝑁𝑚 ℎ𝑜𝑔𝑔𝑖𝑛𝑔
𝑏 =𝑏 , +𝑏 +𝑏 ,
𝑏 =𝑏 , +𝑏 +𝑏 ,
Compression Area (𝐴 ):
(𝐾 − 𝐾 )𝑏𝑑 𝑓 (0.3 − 0.295)𝑥300𝑥580 𝑥17
𝐴 = = = 37.23 𝑚𝑚
𝑓 (𝑑 − 𝑑 ) 434.78𝑥(580 − 50)
Page 28
Reinforced Concrete Structures I
This small area of reinforcement can be provided by extending the bottom span bars beyond the
internal supports.
Tension Area (𝐴 ):
𝑑
𝑧= 1 + 1 − 2𝐾 = 0.82𝑑 = 0.82(580) = 475.60 ≤ 0.95𝑑
2
.
𝐴 = +𝐴 = + 37.23 = 2484.81 𝑚𝑚
. .
𝐴 = = = 1343.7 𝑚𝑚
.
Page 29
Reinforced Concrete Structures I
. .
𝐶 , = = = 0.12 𝑁/𝑚𝑚
.
Assuming all the tension reinforcement is taken onto supports and anchored:
.
ρ = = = 0.014 < 0.02 𝑂𝑘
𝜎 =0
/ / / /
𝑣 = 0.035𝑘 𝑓 = 0.035(1.577) (30) = 0.38 𝑁/𝑚𝑚
𝑉 , = [𝐶 , 𝑘(100𝜌 𝑓 ) + 𝑘 𝜎 ]𝑏 𝑑
Page 30
Reinforced Concrete Structures I
𝑉 , = 𝑧𝑓 cot 𝜃 ≥ 𝑉 = 284.5 𝑘𝑁
⇒ ≥ ( . )( )( . )
= 0.48
.
100.531
𝑠≤ = 207.41 𝑚𝑚
0.48
Hence provide 𝜙8 at 200 mm c/c (𝑨𝒔𝒘 /𝒔 = 𝟎. 𝟒𝟖)
Additional longitudinal tensile force
∆ 𝐹 = 0.5𝑉 cot 𝜃 = 0.5 𝑥 284.5 𝑥 2.5 = 355.63 𝑘𝑁
This additional longitudinal tensile force is provided for by extending the
curtailment point of longitudinal reinforcement.
Shear links in end spans at supports B and C
At d distance from face of support:
𝑉 = 570 − 190 𝑥 (0.15 + 0.58) = 431.30 𝑘𝑁
𝑉 , = 𝑧𝑓 cot 𝜃 ≥ 𝑉 = 431.30 𝑘𝑁
⇒ ≥ ( . )( )( . )
= 0.76
.
157.08
𝑠≤ = 206.64 𝑚𝑚
0.76
𝑨𝒔𝒘
Hence provide 𝜙10 at 200 mm c/c ( = 𝟎. 𝟕𝟔)
𝒔
𝑉 , = 𝑧𝑓 cot 𝜃 ≥ 𝑉 = 379.5 𝑘𝑁
⇒ ≥ ( . )( )( . )
= 0.65
.
157.08
𝑠≤ = 242.95 𝑚𝑚
0.65
Page 31
Reinforced Concrete Structures I
𝑨𝒔𝒘
Hence provide 𝜙10 at 230 mm c/c ( = 𝟎. 𝟔𝟖)
𝒔
𝜌 , = (0.08 𝑓 )/𝑓
= (0.08√30)/500 = 0.001
𝜌 , = 𝐴 /(𝑠𝑏 sin 𝛼)
= 0.335(0.9𝑥600)(434.78)(2.5) = 𝟏𝟗𝟔. 𝟔𝟑 𝑘𝑁
Maximum spacing of links, 𝑠 , is
𝑠 = 0.75𝑑 = 0.75 𝑥 600 = 450 𝑚𝑚
Page 32
Reinforced Concrete Structures I
Based on this dimensions the links are arranged as shown in Fig. below.
Sketch
Page 33
Reinforced Concrete Structures I
1𝑥24 = 24 𝑚𝑚
The provided clear distance = 71 𝑚𝑚 > 𝑚𝑎𝑥 𝑑 + 5 𝑚𝑚
20 𝑚𝑚
Therefore, it is ok!
Page 34
Reinforced Concrete Structures I
Solution
Material Properties:
. .
For C30 concrete: 𝑓 = 30 𝑀𝑃𝑎 →𝑓 = = = 17 𝑀𝑃𝑎
.
/ /
→𝑓 = 0.3𝑓 = 0.3(30) = 2.9 𝑀𝑃𝑎
Load Combination:
Design load w:
𝑤 = 1.35𝑔 + 1.5𝑞 = 1.35𝑥30.2 + 1.5𝑥11.5 = 58.02 𝑘𝑁/𝑚
Analysis
Design moment 𝑀 (𝑘𝑁𝑚):
Page 35
Reinforced Concrete Structures I
Flexural Design:
Effective depth:
Assume diameter of main bar (𝜙) = 26 𝑚𝑚 with concrete cover 35 mm and 10 mm link diameter.
Flexure in span:
𝑀 = 146.9 𝑘𝑁𝑚
2
𝑀 = 0.295𝑓𝑐𝑑𝑏𝑑
= 0.295𝑥17𝑥300𝑥392 = 231.187 𝑘𝑁𝑚
Since 𝑀 > 𝑀 = 146.9 𝑘𝑁𝑚 design as singly reinforced beam.
𝑀 146.9𝑥10
𝐾= = = 0.187
𝑏𝑑 𝑓 300𝑥392 𝑥17
𝑑 392
𝑧= 1 + √1 − 2𝐾 = 1+ 1 − 2(0.187) = 350.97 𝑚𝑚 ≤ 0.95𝑑
2 2
𝑀 146.9 𝑥 10
𝐴 = = = 962.55 𝑚𝑚
𝑓 𝑧 434.78 𝑥 350.97
⇒ 𝑷𝒓𝒐𝒗𝒊𝒅𝒆 𝟐𝝓𝟐𝟔 (𝑨𝒔 = 𝟏𝟎𝟔𝟏. 𝟖𝟔 𝒎𝒎𝟐 )
Flexure, support:
𝑀 = 261 𝑘𝑁𝑚
Since 𝑀 < 𝑀 = 261 𝑘𝑁𝑚 design as doubly reinforced beam.
Compression Area (𝐴 ):
𝑀−𝑀 (261 − 231.187)𝑥10
𝐴 = = = 202.54 𝑚𝑚
𝑓 (𝑑 − 𝑑 ) 434.78(392 − 53)
𝑷𝒓𝒐𝒗𝒊𝒅𝒆 𝟐𝝓𝟏𝟔 𝑩
Tension Area (𝐴 ):
𝑑
𝑧= 1 + 1 − 2𝐾 = 0.82𝑑 = 0.82(392) = 321.44 ≤ 0.95𝑑
2
Page 36
Reinforced Concrete Structures I
𝑀 231.187𝑥10
𝐴 = +𝐴 = + 202.54 = 1856.76 𝑚𝑚
𝑧𝑓 321.44(434.78)
⇒ 𝑷𝒓𝒐𝒗𝒊𝒅𝒆 𝟒𝝓𝟐𝟔 (𝐴 = 2123.72 𝑚𝑚 ) 𝑻
Shear Design:
a) Support B (critical)
Shear at central support = 217.6 𝑘𝑁
Design Shear Force, 𝑉 :
This should be determined at distance d from the face of the support.
𝑉 = 217.6 − 58.02(0.15 + 𝑑) = 217.6 − 58.02𝑥0.542 = 186.153 𝑘𝑁
Shear Resistance of Concrete (𝑉 , ):
. .
𝐶 , = = = 0.12 𝑁/𝑚𝑚
.
Assuming all the tension reinforcement is taken onto supports and anchored:
.
ρ = = = 0.018 < 0.02 𝑂𝑘
𝜎 =0
/ / / /
𝑣 = 0.035𝑘 𝑓 = 0.035(1.714) (30) = 0.43 𝑁/𝑚𝑚
𝑉 , = [𝐶 , 𝑘(100𝜌 𝑓 ) + 𝑘 𝜎 ]𝑏 𝑑
Page 37
Reinforced Concrete Structures I
𝜌 , = (0.08 𝑓 )/𝑓
= (0.08√30)/500 = 0.0009
𝜌 , = 𝐴 /(𝑠𝑏 sin 𝛼)
⇒ =( )( )( . )
= 0.48
. .
𝐴
𝑠≤ = 327
0.48
Hence provide 𝜙10 at 290 mm c/c (𝑨𝒔𝒘 /𝒔 = 𝟎. 𝟓𝟒)
b) Support A and C
Shear at end support = 130.6 𝑘𝑁
Design Shear Force, 𝑉 :
At distance d from the face of the support.
𝑉 = 130.6 − 58.02(0.15 + 𝑑) = 130.6 − 58.02𝑥0.542 = 99.15 𝑘𝑁
Shear Resistance of Concrete (𝑉 , ):
. .
𝐶 , = = = 0.12 𝑁/𝑚𝑚
.
Assuming all the tension reinforcement is taken onto supports and anchored:
.
ρ = = = 0.009 < 0.02 𝑂𝑘
𝜎 =0
/ / / /
𝑣 = 0.035𝑘 𝑓 = 0.035(1.714) (30) = 0.43 𝑁/𝑚𝑚
Page 38
Reinforced Concrete Structures I
𝑉 , = [𝐶 , 𝑘(100𝜌 𝑓 ) + 𝑘 𝜎 ]𝑏 𝑑
𝜌 , = (0.08 𝑓 )/𝑓
= (0.08√30)/500 = 0.0009
𝜌 , = 𝐴 /(𝑠𝑏 sin 𝛼)
⇒ =( )( )( . )
= 0.26
. .
𝐴
𝑠≤ = 604
0.26
Hence provide 𝜙10 at 290 mm c/c (𝑨𝒔𝒘 /𝒔 = 𝟎. 𝟓𝟒)
= 0.26(0.9𝑥392)(434.78)(2.5) = 99.7 𝑘𝑁
Shear links are required at each end of the beam from the face of the support to the point where
the design shear force is 𝑉 = 99.7 𝑘𝑁 on the shear force diagram of the beam.
From the face of the support B:
𝑉 −𝑉 186.153 − 99.7
𝑥= = = 1.5 𝑚
𝑤 58.02
Page 39
Reinforced Concrete Structures I
Summary of design:
1𝑥26 = 26 𝑚𝑚
The provided clear distance = 35𝑚𝑚 > 𝑚𝑎𝑥 𝑑 + 5 𝑚𝑚
20 𝑚𝑚
Therefore, it is ok!
Curtailment of main bars
Bottom: curtail
75% main bars 0.08𝑙 from end support = 480 𝑚𝑚 say 450 𝑚𝑚 𝑓𝑟𝑜𝑚 𝐴
70% main bars 0.30𝑙 – 𝑎 = 0.3 × 6000 − 1.125 × 𝑑
= 1800 − 1.125 × 392
= 1359 mm say 1350 from A
Top: curtail
40% main bars 0.15𝑙 + 𝑎 = 900 + 441
= 1341 mm say 1350 from B
Page 40
Reinforced Concrete Structures I
Page 41
Reinforced Concrete Structures I
Design Loads
The total load is carried by two L-beams. All the load acting on 0.8 m width acts on an L-beam.
The dead load carried by each L-beam is
[(0.12 𝑠𝑙𝑎𝑏 + 0.03 𝑠𝑐𝑟𝑒𝑒𝑑) × 0.8 + 0.2 × (0.4 – 0.12) 𝑟𝑖𝑏] × 25
+ 16 × 9.81𝑥 10 ℎ𝑎𝑛𝑑 𝑟𝑎𝑖𝑙𝑠 = 4.6 𝑘𝑁/𝑚
The total live load acting on each beam is 0.8 × 5 = 4.0 𝑘𝑁/𝑚
Design load = (1.35 × 4.6) + (1.5 × 4) = 12.21 𝑘𝑁/𝑚
Analysis
Ultimate moment at mid-span = 12.21 × 7 /8 = 74.8 𝑘𝑁 𝑚
Shear Force 𝑉 at support:
𝑤𝑙 12.21𝑥7
𝑉= = = 42.74 𝑘𝑁
2 2
Page 42
Reinforced Concrete Structures I
Effective Width
1600 − 2𝑥200
𝑏 = = 600 𝑚𝑚
2
𝑙 = Span of simply supported beam = 7000 mm
𝑏 = 𝑏 , +𝑏 ≤𝑏
Page 43
Reinforced Concrete Structures I
Flexural Design
𝑀 74.8 𝑥 10
𝐾= = = 0.055
𝑏 𝑑 𝑓 800 𝑥 3472 𝑥 14.167
𝑑 347
𝑧= 1 + √1 − 2𝐾 = 1+ 1 − 2(0.055) = 337.18 𝑚𝑚 ≤ 0.95𝑑
2 2
𝑀 74.8 𝑥 10
𝐴 = = = 521.9 𝑚𝑚2
𝑓 𝑧 434.783 𝑥 329.65 𝑚𝑚
⇒ 𝑷𝒓𝒐𝒗𝒊𝒅𝒆 𝟐𝝓𝟐𝟎 (𝑨𝒔 = 𝟔𝟐𝟖. 𝟑𝟐 𝒎𝒎𝟐 )
Check the minimum and maximum area of reinforcement
Assuming all the tension reinforcement is taken onto supports and anchored:
.
ρ = = = 0.009 < 0.02 𝑂𝑘
𝜎 =0
/ / / /
𝑣 = 0.035𝑘 𝑓 = 0.035(1.76) (25) = 0.409 𝑁/𝑚𝑚
𝑉 , = [𝐶 , 𝑘(100𝜌 𝑓 ) + 𝑘 𝜎 ]𝑏 𝑑
Page 44
Reinforced Concrete Structures I
Since 𝑉 , > 𝑉 no shear reinforcement is required but nominal minimum reinforcement will
be provided.
Check for crushing of the concrete strut at the maximum shear force
Crushing strength of diagonal strut:
(𝑉 /𝑏 𝑑)
𝜃 = 0.5 sin
0.153𝑓 (1 − 𝑓 /250)
(38510/200𝑥347)
𝜃 = 0.5 sin = 4.638
0.153𝑥25(1 − 25/250)
cot 𝜃 = 12.33
The value of 𝑐𝑜𝑡 𝜃 is outside the limits of 1.0 and 2.5. Therefore, assume cot 𝜃 = 2.5:
𝜌 , = (0.08 𝑓 )/𝑓
= (0.08√25)/500 = 0.0008
𝜌 , = 𝐴 /(𝑠𝑏 sin 𝛼)
Page 45
Reinforced Concrete Structures I
1𝑥20 = 20 𝑚𝑚
The provided clear distance = 74 𝑚𝑚 > 𝑚𝑎𝑥 𝑑 + 5 𝑚𝑚
20 𝑚𝑚
Therefore, it is ok!
End anchorage
The area of bottom reinforcement provided at supports with little or no end fixity
should be at least 25% of the area of steel provided in the span.
The tensile force 𝐹 to be anchored is given by
𝑎
𝐹 = |𝑉 |
𝑧
𝑎 is given as
𝑧
𝑎 = (cot 𝜃 − cot 𝛼)
2
𝛼 = angle of shear reinforcement and for vertical links, 𝛼 = 90° 𝑎𝑛𝑑 𝑐𝑜𝑡 𝛼 = 0.
𝑎
cot 𝜃 ≈ 2.5 = 1.25
𝑧
𝐹 = 1.25𝑉
The bond length needed is measured from the line of contact between the beam and the support.
At support, 𝑉 = 38.5 𝑘𝑁. 𝐹 = 1.25 × 38.51 = 48.14 𝑘𝑁.
Area of steel required to resist this force =
48.14𝑥10
= = 110.72 𝑚𝑚
434.783
As all the steel is carried over to the support, area of steel provided is that of 2𝜙20 equal to
628.32 𝑚𝑚 > 110.72 𝑚𝑚 .
For 𝑓 = 25 𝑀𝑃𝑎, the bond length is 40 bar diameters.
The bond length ℓ = (𝐴 /𝐴 ) × (40 × 20).
110.72
𝑙 = 𝑥(40𝑥20) = 141 𝑚𝑚
628.32
Page 46
Reinforced Concrete Structures I
Deflection check
The deflection of the beam is checked using the equation:
, .
= = 1.23
, .
.
𝜌= = = 0.009, 𝜌% = 0.91
𝐿 𝜌 1 𝜌
= 𝐾 11 + 1.5 𝑓 + 𝑓 𝑖𝑓 𝜌 > 𝜌
𝑑 𝜌−𝜌 12 𝜌
= 20.38
= 20.38 𝑥 0.8 = 16.3
,
𝐿/𝑑 ratio corrected for is 16.3𝑥1.23 = 20
,
From Table of maximum bar spacing for crack control, for 0.3 mm crack width, maximum spacing
is approximately 117 mm. The actual spacing provided is 74 mm does not exceed 117 mm. The
beam is satisfactory with regard to cracking.
Page 47