MasterTop® 314UL
Thickness (in mm) Coverage (Sqm per Pack)
Depending on the substrate condition, apply 5.5 to 1.0 12.95
6.5 m2/kg of the primer, using a roller or squeegee. 1.5 8.60
2.0 6.45
BODY COAT
3.0 4.32
Mixing
Mix MasterTop 314UL Part A with MasterTop
314UL Part B and mix for at least 2 minutes until the PACKAGING
mix is uniform and free of streaks. Continue to mix MasterTop 314UL Part A 5.00 kg/pail
slowly adding MasterTop Filler F 30. Mix for a
further 3 minutes until a uniform mass and colour is MasterTop 314UL Part B Part B 1.94 kg/pail
obtained. MasterTop Filler F30 17.06 kg/bag
Placing
The mixed MasterTop 314 UL shall be applied to SHELF LIFE
the prepared and primed surface without any delay MasterTop 314UL has a shelf life of 12 months.
using a trowel / depth set rake to achieve desired
thickness. Rolling should commence immediately Store out of direct sunlight, clear of the ground on
with spike roller in order to release any entrapped pallets protected from rainfall.
air from the mix and also to blend out any trowel
mark.
PRECAUTIONS
Curing
It is highly recommended to use necessary PPE
Waiting times between MasterTop P1620 and (Gloves, mask etc.,) during installation of the
MasterTop 314UL should not be less than 16 product. In case of Incidents of direct inhalation,
hours and not more than 48 hours. Where extended causing dizziness/giddiness, loss of
over coating times are envisaged then the cured consciousness, contact with eyes etc, seek
primer reactivated by lightly abrading the surface immediate medical advice. The requirements may
and solvent wiping. MasterTop 314UL should be vary depending on the application areas. Please
protected from traffic and spillage for at least 48 ensure to have proper ventilation while working in
hours. Full chemical and mechanical resistance is confined areas. Contact Master Builders Solutions
obtained after 7 days. representative in case you need further details or
Application of subsequent resin topping shall be refer to the material safety datasheet of the product
commenced after 24 Hrs but not later than 48 Hrs to know more.
after the installation of MasterTop 314UL .
Refer TDS no : MasterTop 314UL/03/04/2021
ESTIMATING DATA
A 24.00 kg unit of MasterTop 314UL on fair faced
primed substrate can cover:
STATEMENT OF The technical information and application advice given in this Master Builders Solutions publication are based on the
RESPONSIBILITY present state of our best scientific and practical knowledge. As the information herein is of a general nature, no
(Disclaimer) assumption can be made as to a product's suitability for a particular use or application and no warranty as to its
accuracy, reliability or completeness either expressed or implied is given other than those required by law. The user is
responsible for checking the suitability of products for their intended use.
NOTE Field service where provided does not constitute supervisory responsibility. Suggestions made by Master Builders
Solutions either orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since
they, and not Master Builders Solutions, are responsible for carrying out procedures appropriate to a specific
application.
Master Builders Solutions India Private Limited
Registered office: Plot No D-126,
TTC Industrial Area, MIDC,
Shiravane, Navi Mumbai - 400706,
Maharashtra, India
Tel: +91 8657906776
E-mail: [email protected]
www.master-builders-solutions.com/en-in