0% found this document useful (0 votes)
4 views

r011engd

The document outlines the features and specifications of the iQ Platform-compatible PAC OPC UA Server Module, emphasizing the importance of OPC UA for flexible and secure data utilization in manufacturing. It highlights three key strengths of OPC UA: unified communication, security against data leakage, and improved interoperability for data sharing. Additionally, it provides detailed hardware and software specifications for the server module, including security settings and communication capabilities.

Uploaded by

Clinton Dsa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4 views

r011engd

The document outlines the features and specifications of the iQ Platform-compatible PAC OPC UA Server Module, emphasizing the importance of OPC UA for flexible and secure data utilization in manufacturing. It highlights three key strengths of OPC UA: unified communication, security against data leakage, and improved interoperability for data sharing. Additionally, it provides detailed hardware and software specifications for the server module, including security settings and communication capabilities.

Uploaded by

Clinton Dsa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

iQ Platform-compatible PAC

OPC UA Server Module


Broadcast

OPC UA: Essential to stay ahead with data utilization


Today's manufacturing requires flexible, fast data utilization.
Open Platform Communications
The key is to add value to data by seamlessly connecting shop Unified Architecture
floor and IT systems.
▶OPC UA, anticipated as the standard for supporting International data exchange standard for safe, reliable,
manufacturer- and platform-independent industrial
digital transformation in manufacturing, is essential for
communication
success in data utilization

Integrate the strengths of OPC UA into programmable controller systems


Resolve your concerns about data utilization with the three key strengths of OPC UA!

Unified communication protocol between systems


Adapting to communication
Concern protocols for devices from ●OPC UA enables communication with a unified protocol between devices and
various manufacturers and IT systems, thereby creating an open, manufacturer-independent network

01
systems, both old and new, is
time-consuming and costly Connect
Connect devices and IT systems with minimal effort and cost

Connection destination authentication, communication encryption


Concern With large amounts of critical ●OPC UA ensures highly reliable communication with its robust security
data being exchanged more features, including certificates, encryption, and signatures
frequently, how can we
02 prevent data leakage? Secure
Protect data from theft and tampering

Communicating the meaning and relationships of data


The need for updates on the ●OPC UA enhances system interoperability by standardizing data structures
Concern link application each time and interfaces using information models
new equipment is added ●Various information models provided by industry organizations and vendors

03 complicates data sharing are planned to be supported


and system coordination
Communicate
Ensure smooth data sharing and coordination between systems
OPC UA server module hardware specifications
Item RD81OPC96
SD memory card slot SD memory card/SDHC memory card (2…16 GB)
Ethernet port
Number of channels 2
Interface*1 1000BASE-T, 100BASE-TX, 10BASE-T
Max. number of cascaded stages*2 2 (100 Mbps), 4 (10 Mbps)
Max. segment length*3 (m) 100 (between hub and node)
Interface RJ45
Setup software
MX OPC UA Module Configurator-R SW1DND-ROPCUA-E
*1. The OPC UA server module determines 11000BASE-T/100BASE-TX/10BASE-T, and full/half duplex communication modes according to the hub.
When connecting to a hub that does not have auto-negotiation feature, configure the hub settings to match the communication mode.
*2. Based on use with a repeater hub. For switching hub, refer to the manufacturer’s documentation.
*3. For maximum segment length between hubs, refer to switching hub manufacturer documentation.

OPC UA server module software specifications


Item Specifications
Profile Embedded 2017 UA Server Profile, OPC Spec Version1.04
• None: no security
• Aes256-Sha256-RsaPss: AES 256-bit encryption + SHA-256
• Aes128-Sha256-RsaOaep: AES 128-bit encryption + SHA-256
Encryption setting (security policy)*4
• Basic256Sha256: Basic 256-bit encryption + SHA-256
• Basic256 (deprecated): Basic 256-bit encryption
• Basic128Rsa15 (deprecated): Basic 128-bit encryption
• None: no security
Signature setting (security mode) • Sign: add signature
• Sign & Encrypt: add signature and encryption
• Anonymous
User authentication setting • User name/password
• Certificate validation
Connected OPC UA clients
Maximum number of sessions 15
Connectable Ethernet port CH1
OPC UA communication specifications*5
CreateMonitoredItems SamplingInterval (ms) 200…60000
ModifyMonitoredItems Max. number of MonitoredItems Total for all sessions: 3000
CreateSubscription Per session: 10
Max. number of Subscriptions
ModifySubscription Total for all sessions: 150
MaxNodesPerRead
Read 25000
Max. number of nodes per request
MaxNodesPerWrite
Write 3000
Max. number of nodes per request
Information models and mapping specifications*5
Namespace Number of Namespaces 10
Number of Nodes 50000
Node Number of mappable Variables
25000
(total)
*4. Available security policies differ for each firmware version of the OPC UA server module and software version of the configuration tool. For details, please refer to the “MELSEC iQ-R OPC UA Server Module User’s
Manual (Application) (SH-081694ENG)”.
*5. Either tag mode or information model mode can be selected depending on the use. This specification refers to the information model mode.
For details on the tag mode, please refer to “MELSEC iQ-R OPC UA Server Module User’s Manual (Startup) (SH-081693ENG)”.
For details on the information model mode, please refer to “MELSEC iQ-R OPC UA Server Module User’s Manual (Information Model) (SH-082679ENG)”.

OPC UA logo and OPC CERTIFIED logo are registered trademarks of OPC Foundation.
This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit (http://www.openssl.org/).

Country/Region, Sales office


USA ····················· +1-847-478-2100 France··············· +33-1-55-68-55-68 Taiwan ·············· +886-2-2299-2499 • Company names and product names used
Mexico ·············· +52-55-3067-7500 Czech Republic ··· +420-734-402-587 Korea ·················· +82-2-3660-9569 in this document are trademarks or registered trademarks
Brazil··················+55-11-4689-3000 Poland················ +48-12-347-65-00 Singapore ·············· +65-6473-2308 of their respective companies.
Germany ··············· +49-2102-486-0 Sweden ················ +46-8-625-10-00 Thailand ············ +66-2682-6522-31
UK······················+44-1707-28-8780 Turkey ··············· +90-216-969-2500 Vietnam ············ +84-28-3910-5945 For safe use
Ireland···················+353-1-4198800 UAE ······················+971-4-3724716 Indonesia ············+62-21-31926461
• To use the products listed in this publication properly,
Italy ························ +39-039-60531 South Africa ········· +27-11-658-8100 India ···················+91-20-2710-2000
Spain ·················· +34-935-65-3131 China ················ +86-21-2322-3030 Australia ·············· +61-2-9684-7777 always read the relevant manuals before use.

HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

New publication, effective September 2024.


R011ENG-D 2409(IP) Specifications are subject to change without notice.