The FLOWSIC600 is an ultrasonic flowmeter designed for reliable measurement in process applications, featuring long-term stability and low maintenance. It measures various gas types and operates under harsh industrial conditions, with extensive diagnostic capabilities. The device supports a wide range of operating pressures and temperatures, making it suitable for diverse applications.

Uploaded by

smeersaikia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views3 pages

Endress-Hauser IFL600 EN

The FLOWSIC600 is an ultrasonic flowmeter designed for reliable measurement in process applications, featuring long-term stability and low maintenance. It measures various gas types and operates under harsh industrial conditions, with extensive diagnostic capabilities. The device supports a wide range of operating pressures and temperatures, making it suitable for diverse applications.

Uploaded by

smeersaikia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Products Solutions Services

FLOWSIC600
ultrasonic flowmeter
Reliable flowmeter for process applications

F L E X Benefits:
• Long-term stability, reliable measurement
• Low maintenance due to intelligent self-diagnostics
• Virtually immune to pressure regulator noise
• Ultrasonic transducers can be exchanged under operating pressure
• Wide application range

Specs at a glance
• Measured variables Volumetric flow, a. c., volume a. c., gas
velocity, sound velocity
• Measuring Medium Natural gas, air, C2H4, steam, process gases
(e. g. CO2 up to 100%, N2, O2, Cl2 etc.), gases like sour gas or bio
gas with high H2S content
More information and current pricing: • Nominal pipe size 2" ... 24" (DN 50 ... DN 600)
www.endress.com/IFL600

Field of application: The FLOWSIC600 is an ultrasonic flowmeter that


sets the standard in its market segment. The design shows that it is
geared towards the harsh conditions of the industry. Thanks to its
compact design with integrated cable routing, the measuring system is
durable, fail-safe, low-maintenance, and exhibits long-term stability. The
FLOWSIC600 has extensive diagnostic options that allow faults to be
detected before the measurement is affected and offers process
monitoring based on the speed of sound.

Features and specifications

Gas Measuring principle


Ultrasonic transit time difference measurement
IFL600

Gas Measured variables


Volumetric flow, a. c., volume a. c., gas velocity, sound velocity

Measuring Medium
Natural gas, air, C2H4, steam, process gases (e. g. CO2 up to 100%, N2,
O2, Cl2 etc.), gases like sour gas or bio gas with high H2S content

Repeatability
< 0.1 % of the measured value

Accuracy
2-path version ≤ ± 1 %

4-path version ≤ ± 0.5 %


Typical accuracy, see application specific data for detailed information

Medium temperature range


ATEX:
–40 °C ... +105 °C at T1, T2, T3;
–40 °C ... +91 °C at T4
Other Ex certifications: –40 °C ... +180 °C

Operating pressure range


0 bar (g) ... 250 bar (g)
On request: Up to 450 bar (g)

Nominal pipe size


2" ... 24"
(DN 50 ... DN 600)

Metrological approvals and certificates


ISO 17089-2
MTBF: 15.4 years

2 Endress+Hauser
IFL600

Gas Hazardous area approvals


IECEx:
Gb/Ga Ex db eb ib [ia Ga] IIA T4
Gb/Ga Ex db eb ib [ia Ga] IIC T4
Ultrasonic transducers intrinsically safe

ATEX:
II 1/2 (1) G Ex ia/db eb ia [ia Ga] IIA/IIB/IIC T4...T1 Ga/Gb
III 1/2 (1) G Ex ia/db eb ia [ia Ga] IIC T6 Ga/Gb
Ultrasonic transducers intrinsically safe

NEC/CEC (US/CA):
Class I, Division 1, Groups B, C, D T4
Class I, Division 2, Groups A, B, C, D T4
Class I, Division 1, Group D T4
Class I, Division 2, Group D T4
Ultrasonic transducers intrinsically safe

Digital Outputs
3 outputs:
30 V, 10 mA
Passive, electrically isolated, Open Collector or according to NAMUR (EN
50227), fmax = 6 kHz
(scalable)

Digital communication
Modbus ASCII
Modbus RTU
HART

More information www.endress.com/IFL600