Products Solutions Services
FLOWSIC600
ultrasonic flowmeter
Reliable flowmeter for process applications
F L E X Benefits:
• Long-term stability, reliable measurement
• Low maintenance due to intelligent self-diagnostics
• Virtually immune to pressure regulator noise
• Ultrasonic transducers can be exchanged under operating pressure
• Wide application range
Specs at a glance
• Measured variables Volumetric flow, a. c., volume a. c., gas
velocity, sound velocity
• Measuring Medium Natural gas, air, C2H4, steam, process gases
(e. g. CO2 up to 100%, N2, O2, Cl2 etc.), gases like sour gas or bio
gas with high H2S content
More information and current pricing: • Nominal pipe size 2" ... 24" (DN 50 ... DN 600)
www.endress.com/IFL600
Field of application: The FLOWSIC600 is an ultrasonic flowmeter that
sets the standard in its market segment. The design shows that it is
geared towards the harsh conditions of the industry. Thanks to its
compact design with integrated cable routing, the measuring system is
durable, fail-safe, low-maintenance, and exhibits long-term stability. The
FLOWSIC600 has extensive diagnostic options that allow faults to be
detected before the measurement is affected and offers process
monitoring based on the speed of sound.
Features and specifications
Gas Measuring principle
Ultrasonic transit time difference measurement
IFL600
Gas Measured variables
Volumetric flow, a. c., volume a. c., gas velocity, sound velocity
Measuring Medium
Natural gas, air, C2H4, steam, process gases (e. g. CO2 up to 100%, N2,
O2, Cl2 etc.), gases like sour gas or bio gas with high H2S content
Repeatability
< 0.1 % of the measured value
Accuracy
2-path version ≤ ± 1 %
4-path version ≤ ± 0.5 %
Typical accuracy, see application specific data for detailed information
Medium temperature range
ATEX:
–40 °C ... +105 °C at T1, T2, T3;
–40 °C ... +91 °C at T4
Other Ex certifications: –40 °C ... +180 °C
Operating pressure range
0 bar (g) ... 250 bar (g)
On request: Up to 450 bar (g)
Nominal pipe size
2" ... 24"
(DN 50 ... DN 600)
Metrological approvals and certificates
ISO 17089-2
MTBF: 15.4 years
2 Endress+Hauser
IFL600
Gas Hazardous area approvals
IECEx:
Gb/Ga Ex db eb ib [ia Ga] IIA T4
Gb/Ga Ex db eb ib [ia Ga] IIC T4
Ultrasonic transducers intrinsically safe
ATEX:
II 1/2 (1) G Ex ia/db eb ia [ia Ga] IIA/IIB/IIC T4...T1 Ga/Gb
III 1/2 (1) G Ex ia/db eb ia [ia Ga] IIC T6 Ga/Gb
Ultrasonic transducers intrinsically safe
NEC/CEC (US/CA):
Class I, Division 1, Groups B, C, D T4
Class I, Division 2, Groups A, B, C, D T4
Class I, Division 1, Group D T4
Class I, Division 2, Group D T4
Ultrasonic transducers intrinsically safe
Digital Outputs
3 outputs:
30 V, 10 mA
Passive, electrically isolated, Open Collector or according to NAMUR (EN
50227), fmax = 6 kHz
(scalable)
Digital communication
Modbus ASCII
Modbus RTU
HART
More information www.endress.com/IFL600
Endress+Hauser AG addresses.endress.com
Switzerland [email protected]